F20
TECH-DATA
E119 FIRE-RESISTIVE DOOR FRAMES WITH LITES, UL LABELED
FOR 1-3/4" THICK DOORS, HANDED. TO BE INSTALLED IN
FIRE RATED GYPSUM BOARD OR MASONRY WALLS
FRAMES ARE FIRE TESTED TO ASTM E119 OR UL 263AND LIMIT THE TRANSFER OF RADIANT HEAT
Views shown apply to pages F20-3 thru F20-9
TECH-DATAE119 FIRE-RESISTIVE FRAMES
E119 FIRE-RESISTIVE WINDOW FRAMES WITH LITES,
UL LABELED TO BE INSTALLED IN FIRE RATED
GYPSUM BOARD OR MASONRY WALLS
FRAMES ARE FIRE TESTED TO ASTM E119 OR UL 263AND LIMIT THE TRANSFER OF RADIANT HEAT
Views shown apply to pages F20-3 thru F20-9
TECH-DATAE119 FIRE-RESISTIVE 60 MINUTE FLUSH GLAZING
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO
HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY
OTHERS)
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS
ALTERNATES BY OTHERS:
A. HARDWOOD
B. CALCIUM SILICATE
C. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
3. *GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS. ACCEPTABLE ALTERNATIVES:
WELL PACKED ROCKWOOL, CONTINUOUS INTUMESCENT CAULKING, OR
CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES: HARDWOOD, CALCIUM SILICATE,
OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS.
7. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY, PLACED 20" O.C.. ANCHOR
SCREWS BY OTHERS. MAX. HEAD DIA. 3/8"; MAX. SHANK DIA. 1/4" x 3" (MIN.
LENGTH). SEE NOTES # 10, 11 & 12 FOR ACCEPTABLE ANCHOR SCREWS.
8. 16 GAGE FIRE RATED FRAME.
9. 16 GAGE STEEL GLAZING BEAD BY CECO DOOR. INSTALL IN FIELD OVER GLAZING
BEAD SCREW, FURNISHED WITH FRAME.
10. FOR WOOD STUD ANCHOR SCREWS SEE:
www.mcmaster.com/#standard-anchors/=14l1dkp
11. FOR STEEL STUD ANCHOR SCREWS SEE:
www.us.hilti.com/screw-fastening/metal-construction-screws/r2007
12. FOR MASONRY FASTENERS SEE: www.tapcon.com/professionals or
www.us.hilti.com/anchor-systems/screw-anchors/r6263
13. FRAME IS NOT LOAD BERING. ADDITIONAL BUILDING DESIGN FEATURES MAY BE
REQUIRED FOR UNITS OVER 12' TALL.
60 MINUTE FLUSH GLAZING
GLASS: VETROTECH
CONTRAFLAM 60
MAX VISIBLE GLASS
94-13/16" X 94-13/16" NOT
TO EXCEED 3283 SQ. IN.,
PER LITE.
OVERALL OUT TO OUT
FRAME WIDTH & HEIGHT IS
NOT LIMITED BY FIRE
RATING.
FACE SHALL BE 1-15/16".
DEPTH SHALL BE 2-9/16".
A
HEAD DETAIL
B
HORIZ. MULLION
C
JAMB DETAIL
D
SILL DETAIL
E
VERT. MULLION
CENTER GLAZED OPTIONAL
4 5 7 86
9
2
13
4 5 7 86
9
2
9
2
13
8
8
3
2
9
3
9
5
4
6
7
8
3
2
2 8
3
9
TECH-DATAE119 FIRE-RESISTIVE 60 MIN. FLUSH STRUCTURE GLAZING
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD
ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS
ALTERNATES BY OTHERS:
A. HARDWOOD
B. CALCIUM SILICATE
C. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
3. *GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS. ACCEPTABLE ALTERNATIVES:
WELL PACKED ROCKWOOL, CONTINUOUS INTUMESCENT CAULKING, OR
CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES: HARDWOOD, CALCIUM
SILICATE, OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS.
7. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY, PLACED 20" O.C..
ANCHOR SCREWS BY OTHERS. MAX. HEAD DIA. 3/8"; MAX. SHANK DIA. 1/4" x 3"
(MIN. LENGTH). SEE NOTES # 10, 11 & 12 FOR ACCEPTABLE ANCHOR SCREWS.
8. 16 GAGE FIRE RATED FRAME.
9. 16 GAGE STEEL GLAZING BEAD BY CECO DOOR. INSTALL IN FIELD OVER
GLAZING BEAD SCREW, FURNISHED WITH FRAME.
10. FOR WOOD STUD ANCHOR SCREWS SEE:
www.mcmaster.com/#standard-anchors/=14l1dkp
11. FOR STEEL STUD ANCHOR SCREWS SEE:
www.us.hilti.com/screw-fastening/metal-construction-screws/r2007
12. FOR MASONRY FASTENERS SEE: www.tapcon.com/professionals or
www.us.hilti.com/anchor-systems/screw-anchors/r6263
13. FRAME IS NOT LOAD BERING. ADDITIONAL BUILDING DESIGN FEATURES MAY
BE REQUIRED FOR UNITS OVER 12' TALL.
14. CENTER GLAZED FRAMES NOT AVAILABLE.
60 MINUTE FLUSH GLAZING
GLASS: VETROTECH
CONTRAFLAM STRUCTURE 60
MAX VISIBLE GLASS
138-1/2" X 138-1/2" NOT
TO EXCEED 7574 SQ. IN., PER
LITE.
OVERALL OUT TO OUT FRAME
WIDTH & HEIGHT IS NOT
LIMITED BY FIRE RATING.
FACE SHALL BE 1-15/16".
DEPTH SHALL BE 2-9/16".
A
HEAD DETAIL
B
HORIZ. MULLION
C
JAMB DETAIL
D
SILL DETAIL
E
VERT. MULLION
4 5 7 86
9
2
13
4 5 7 86
9
2
9
2
13
8
8
3
2
9
3
9
5
4
6
7
8
3
2
F20
TECH-DATA
E119 FIRE-RESISTIVE DOOR FRAMES WITH LITES. MECHANICAL
JOINT OF 60 MINUTE FRAME COMPONENTS.
MECHANICAL JOINING OF COMPONENTS IS REQUIRED WHEN OVERALL SIZE OF FRAME IS TOO LARGE
SCREWS(4)
CENTER GLAZED
FLUSH GLAZED
OR TOO HEAVY TO BE LOADED FOR SHIPPING. MECHANICAL JOINING MAY ALSO BE DUE TO JOB SITE
CONDITIONS AND/OR LIMITATIONS RELATED TO SIZE, WEIGHT, AND/OR HANDLING, ETC.
SCREWS(4)
TECH-DATAE119 FIRE-RESISTIVE 90 MINUTE FLUSH GLAZING
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO
HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY
OTHERS)
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS
ALTERNATES BY OTHERS:
A. HARDWOOD
B. CALCIUM SILICATE
C. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
3. *GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS. ACCEPTABLE ALTERNATIVES:
WELL PACKED ROCKWOOL, CONTINUOUS INTUMESCENT CAULKING, OR
CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES: HARDWOOD, CALCIUM SILICATE,
OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS.
7. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY, PLACED 20" O.C.. ANCHOR
SCREWS BY OTHERS. MAX. HEAD DIA. 3/8"; MAX. SHANK DIA. 1/4" x 3" (MIN.
LENGTH). SEE NOTES # 10, 11 & 12 FOR ACCEPTABLE ANCHOR SCREWS.
8. 16 GAGE FIRE RATED FRAME.
9. 16 GAGE STEEL GLAZING BEAD BY CECO DOOR. INSTALL IN FIELD OVER GLAZING
BEAD SCREW, FURNISHED WITH FRAME.
10. FOR WOOD STUD ANCHOR SCREWS SEE:
www.mcmaster.com/#standard-anchors/=14l1dkp
11. FOR STEEL STUD ANCHOR SCREWS SEE:
www.us.hilti.com/screw-fastening/metal-construction-screws/r2007
12. FOR MASONRY FASTENERS SEE: www.tapcon.com/professionals or
www.us.hilti.com/anchor-systems/screw-anchors/r6263
13. FRAME IS NOT LOAD BERING. ADDITIONAL BUILDING DESIGN FEATURES MAY BE
REQUIRED FOR UNITS OVER 12' TALL.
90 MINUTE FLUSH GLAZING
GLASS: VETROTECH
CONTRAFLAM 90
MAX VISIBLE GLASS
94-13/16" X 94-13/16" NOT
TO EXCEED 4435 SQ. IN.,
PER LITE.
OVERALL OUT TO OUT
FRAME WIDTH & HEIGHT IS
NOT LIMITED BY FIRE
RATING.
FACE SHALL BE 1-15/16".
DEPTH SHALL BE 4-5/16".
A
HEAD DETAIL
B
HORIZ. MULLION
C
JAMB DETAIL
D
SILL DETAIL
E
VERT. MULLION
92
3
4 5 7 86
92
3
1
9
2
3
5
4
6
7
8
9
2
3
4 5 7 86
1
9
2
3
8
8
CENTER GLAZED OPTIONAL
2
8
3
9
F20
TECH-DATA
E119 FIRE-RESISTIVE DOOR FRAMES WITH LITES. MECHANICAL
JOINT OF 90 MINUTE FRAME COMPONENTS.
MECHANICAL JOINING OF COMPONENTS IS REQUIRED WHEN OVERALL SIZE OF FRAME IS TOO LARGE
SCREWS(4)
FLUSH GLAZED
OR TOO HEAVY TO BE LOADED FOR SHIPPING. MECHANICAL JOINING MAY ALSO BE DUE TO JOB SITE
CONDITIONS AND/OR LIMITATIONS RELATED TO SIZE, WEIGHT, AND/OR HANDLING, ETC.
TECH-DATAE119 FIRE-RESISTIVE 120 MINUTE FLUSH GLAZING
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO
HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY
OTHERS)
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS
ALTERNATES BY OTHERS:
A. HARDWOOD
B. CALCIUM SILICATE
C. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
3. *GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS. ACCEPTABLE ALTERNATIVES:
WELL PACKED ROCKWOOL, CONTINUOUS INTUMESCENT CAULKING, OR
CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES: HARDWOOD, CALCIUM SILICATE,
OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS.
7. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY, PLACED 20" O.C.. ANCHOR
SCREWS BY OTHERS. MAX. HEAD DIA. 3/8"; MAX. SHANK DIA. 1/4" x 3" (MIN.
LENGTH). SEE NOTES # 10, 11 & 12 FOR ACCEPTABLE ANCHOR SCREWS.
8. 16 GAGE FIRE RATED FRAME.
9. 16 GAGE STEEL GLAZING BEAD BY CECO DOOR. INSTALL IN FIELD OVER GLAZING
BEAD SCREW, FURNISHED WITH FRAME.
10. FOR WOOD STUD ANCHOR SCREWS SEE:
www.mcmaster.com/#standard-anchors/=14l1dkp
11. FOR STEEL STUD ANCHOR SCREWS SEE:
www.us.hilti.com/screw-fastening/metal-construction-screws/r2007
12. FOR MASONRY FASTENERS SEE: www.tapcon.com/professionals or
www.us.hilti.com/anchor-systems/screw-anchors/r6263
13. FRAME IS NOT LOAD BERING. ADDITIONAL BUILDING DESIGN FEATURES MAY BE
REQUIRED FOR UNITS OVER 12' TALL.
120 MINUTE FLUSH GLAZING
GLASS: VETROTECH
CONTRAFLAM 120
MAX VISIBLE GLASS
94-5/8" X 94-5/8" NOT
TO EXCEED 4435 SQ. IN.,
PER LITE.
OVERALL OUT TO OUT
FRAME WIDTH & HEIGHT IS
NOT LIMITED BY FIRE
RATING.
FACE SHALL BE 1-15/16".
DEPTH SHALL BE 4-5/16".
A
HEAD DETAIL
B
HORIZ. MULLION
C
JAMB DETAIL
D
SILL DETAIL
E
VERT. MULLION
CENTER GLAZED OPTIONAL
2
8
3
9
92
3
4 5 7 86
92
3
1
9
2
3
5
4
6
7
8
9
2
3
4 5 7 86
1
9
2
3
8
8
TECH-DATAE119 FIRE-RESISTIVE 120 MIN. FLUSH STRUCTURE GLAZING
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD
ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS
ALTERNATES BY OTHERS:
A. HARDWOOD
B. CALCIUM SILICATE
C. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
3. *GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME
INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS. ACCEPTABLE ALTERNATIVES:
WELL PACKED ROCKWOOL, CONTINUOUS INTUMESCENT CAULKING, OR
CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES: HARDWOOD, CALCIUM
SILICATE, OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS.
7. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY, PLACED 20" O.C..
ANCHOR SCREWS BY OTHERS. MAX. HEAD DIA. 3/8"; MAX. SHANK DIA. 1/4" x
3" (MIN. LENGTH). SEE NOTES # 10, 11 & 12 FOR ACCEPTABLE ANCHOR
SCREWS.
8. 16 GAGE FIRE RATED FRAME.
9. 16 GAGE STEEL GLAZING BEAD BY CECO DOOR. INSTALL IN FIELD OVER
GLAZING BEAD SCREW, FURNISHED WITH FRAME.
10. FOR WOOD STUD ANCHOR SCREWS SEE:
www.mcmaster.com/#standard-anchors/=14l1dkp
11. FOR STEEL STUD ANCHOR SCREWS SEE:
www.us.hilti.com/screw-fastening/metal-construction-screws/r2007
12. FOR MASONRY FASTENERS SEE: www.tapcon.com/professionals or
www.us.hilti.com/anchor-systems/screw-anchors/r6263
13. FRAME IS NOT LOAD BERING. ADDITIONAL BUILDING DESIGN FEATURES MAY
BE REQUIRED FOR UNITS OVER 12' TALL.
120 MINUTE FLUSH GLAZING
GLASS: VETROTECH
CONTRAFLAM STRUCTURE 120
MAX VISIBLE GLASS
126" X 126" NOT
TO EXCEED 4536 SQ. IN., PER
LITE.
OVERALL OUT TO OUT FRAME
WIDTH & HEIGHT IS NOT
LIMITED BY FIRE RATING.
FACE SHALL BE 1-15/16".
DEPTH SHALL BE 4-5/16".
A
HEAD DETAIL
B
HORIZ. MULLION
C
JAMB DETAIL
D
SILL DETAIL
E
VERT. MULLION
CENTER GLAZED OPTIONAL
2
8
3
9
92 3
4 5 7 86
92 3
1
9
2
3
5
4
6
7
8
9
2
3
4 5 7 86
1
9
2
3
8
8
F20
TECH-DATA
E119 FIRE-RESISTIVE DOOR FRAMES WITH LITES. MECHANICAL
JOINT OF 120 MINUTE FRAME COMPONENTS.
MECHANICAL JOINING OF COMPONENTS IS REQUIRED WHEN OVERALL SIZE OF FRAME IS TOO LARGE
SCREWS(4)
FLUSH GLAZED
CENTER GLAZED
OR TOO HEAVY TO BE LOADED FOR SHIPPING. MECHANICAL JOINING MAY ALSO BE DUE TO JOB SITE
CONDITIONS AND/OR LIMITATIONS RELATED TO SIZE, WEIGHT, AND/OR HANDLING, ETC.
SCREWS(4)
TECH-DATAE119 FIRE-RESISTIVE 180 MINUTE CENTER GLAZING
NOTES:
1. SETTING BLOCK (SILL ONLY) BY OTHERS:
A. CALCIUM SILICATE
2. CONTINUOUS FLEXPAN 200 AROUND PERIMETER (3.750" x .188")
FURNISHED WITH E119 FRAME
3. GLAZING TAPE (.125" x .750") FURNISHED WITH E119 FRAME
4. GLAZING SNAP ON BEADS (1.38"x .750"x .094") FURNISHED WITH
E119 FRAME
5. FIRE RATED SEAL BY OTHERS:
A. WELL PACKED ROCKWOOL
6. SHIM AS REQUIRED, BY OTHERS.
7. FINISH SEALANT BY OTHERS
8. ANCHOR HOLES ARE PREDRILLED AT THE FACTORY. ANCHOR
SCREWS SUITABLE FOR GROUT FILLED CMU BY OTHERS. ANCHOR
SCREWS DETERMINED BY INSTALLER BASED ON WALL CONDITION.
9. FLUSH GLAZED FRAMES NOT AVAILABLE
180 MINUTE CENTER GLAZING
GLASS: VETROTECH
CONTRAFLAM 180 PROVIDED
& INSTALLED IN E119 FRAME
MAX VISIBLE GLASS
48" X 48" NOT
TO EXCEED 2304 SQ. IN..
OVERALL OUT TO OUT FRAME
WIDTH & HEIGHT IS LIMITED
to 52" x 52".
DEPTH SHALL BE 6-7/8".
SINGLE LITE WINDOW
(BORROWED LITE) ONLY.
MULLIONS NOT AVAILABLE.
1
2
3
4
5 6
7
8
D
SILL DETAIL
1
2
3
4
5 6
7
8
A
HEAD DETAIL
C
JAMB DETAIL
TECH-DATA E119 FIRE-RESISTIVE 60, 90 & 120 MINUTE FRAME
WITH HOLLOW METAL DOOR
60 MINUTE FRAME FIRE RATING
90 MINUTE FRAME FIRE RATING
90 MINUTE FRAME FIRE RATING
120 MINUTE FRAME FIRE RATING
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 60 Minute 90˚ Corner FrameFire Resistive Products
NOTES:1. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME2. GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME3. ANCHOR SCREWS BY OTHERS - PLACE 20" O.C. MAX. HEAD DIA. 3/8";
MAX. SHANK DIA. 1/4"4. FIRE RATED E119 FRAME5. STEEL GLAZING BEAD INSTALL OVER GLAZING BEAD SCREW6. 16 GA. STEEL SHEET METAL COVER; LENGTH PER E119 FRAME HEIGHT7. INSULATED CORNER POST
NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
F20-10
ASSA ABLOY, the global leader in door opening solutions
March, 2019
NOTES:1. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME2. GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME3. ANCHOR SCREWS BY OTHERS - PLACE 20" O.C. MAX. HEAD DIA. 3/8";
MAX. SHANK DIA. 1/4"4. FIRE RATED E119 FRAME5. STEEL GLAZING BEAD INSTALL OVER GLAZING BEAD SCREW6. 16 GA. STEEL SHEET METAL COVER; LENGTH PER E119 FRAME HEIGHT7. INSULATED CORNER POST
NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
E119 60 Minute Angled FrameFire Resistive Products
F20-11
ASSA ABLOY, the global leader in door opening solutions
March, 2019
Contraflam 60 Structure Joint OptionsFire Resistive Products
114"
12"
138"
Intumescent Interlayer
Joint Sealant Silicone DowCorning DC 895,provided by Vetrotech
SpacerPolysulfide Sealant
2x Kerafix FXL 200 provided by Vetrotech
Safety Glass7
16"
18"
Joint Sealant silicone DowCorning DC 895,provided by Vetrotech
2x Kerafix FXL 200 provided by Vetrotech
Safety Glass
Spacer
Sealing Polysulphide
IntumescentInterlayer
9-1/2O
MAX.ANGLE
CONTRAFLAM 60 STRUCTURE JOINT
CONTRAFLAM 60 ANGLE STRUCTURE JOINT
F20-12
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 90 and 120 Minute 90˚ Frame Corner Fire Resistive Products
NOTES:1. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME2. GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME3. ANCHOR SCREWS BY OTHERS - PLACE 20" O.C. MAX. HEAD DIA. 3/8";
MAX. SHANK DIA. 1/4"4. FIRE RATED E119 FRAME5. STEEL GLAZING BEAD INSTALL OVER GLAZING BEAD SCREW6. 16 GA. STEEL SHEET METAL COVER; LENGTH PER E119 FRAME HEIGHT7. INSULATED CORNER POST
NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
F20-13
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 90 and 120 Minute Angled Frame Fire Resistive Products
NOTES:1. CONTINUOUS INTUMESCENT TAPE FURNISHED WITH E119 FRAME2. GLAZING GASKET (BOTH SIDES) FURNISHED WITH E119 FRAME3. ANCHOR SCREWS BY OTHERS - PLACE 20" O.C. MAX. HEAD DIA. 3/8";
MAX. SHANK DIA. 1/4"4. FIRE RATED E119 FRAME5. STEEL GLAZING BEAD INSTALL OVER GLAZING BEAD SCREW6. 16 GA. STEEL SHEET METAL COVER; LENGTH PER E119 FRAME HEIGHT7. INSULATED CORNER POST
NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BE NEEDED TO HOLD ON VINYL GLAZING GASKET (PROVIDED AND INSTALLED BY OTHERS)
F20-14
ASSA ABLOY, the global leader in door opening solutions
March, 2019
Contraflam 120 Structure Joint OptionsFire Resistive Products
2116"
Spacer
PolysulfideSealant
Joint Sealant SiliconeDowCorning DC 895,provided by Vetrotech
4-8 strips Kerafix FXL 200provided by Vetrotech
Intumescent Interlayer
Safety Glass
19O
2116"
18"
MAX.ANGLE
CONTRAFLAM 120 STRUCTURE JOINT
CONTRAFLAM 120 ANGLE STRUCTURE JOINT
F20-15
ASSA ABLOY, the global leader in door opening solutions
March, 2019
Fire Window FrameFire Resistive Products
60 OR 120 MINUTE MAXIMUM RATINGFIRE RESISTIVE E119 FRAME ASSEMBLYCONTRAFLAM STRUCTURE 60 OR 120 WITHOUT VERTICAL MULLIONS
NOTES:1. SETTING BLOCK (SILL OR HORIZONTAL MULLION ONLY)
BY OTHERS. ALTERNATES BY OTHERS:A. HARDWOODB. CALCIUM SILICATEC. NEOPRENE (90 DUROMETER)
2. CONTINUOUS INTUMESCENT TAPE FURNISHED. E119FRAME INSTALLED BY OTHERS.
3. *GLAZING GASKET (BOTH SIDES) FURNISHED. E119FRAME INSTALLED BY OTHERS
4. FIRE RATED SEAL IN SHIM SPACE BY OTHERS.ACCEPTABLE ALTERNATIVES: WELL PACKEDROCKWOOL, CONTINUOUS INTUMESCENT CAULKING,OR CONTINUOUS INTUMESCENT TAPE.
5. SHIMS BY OTHERS. ACCEPTABLE ALTERNATES:HARDWOOD, CALCIUM SILICATE, OR CEDAR SHINGLES.
6. FINISH SEALANT BY OTHERS
7. ANCHOR SCREWS BY OTHERS. PLACE 20” O.C. MAX.HEAD DIA. 3/8”; MAX. SHANK DIA. 1/4”.
8. FIRE RATED E119 FRAME.
9. STEEL GLAZING BEAD. INSTALL WITH SCREWSFURNISHED.
10. GLASS: VETROTECH CONTRAFLAM STRUCTURE60 OR 120 MINUTE.
11. 60 MINUTE MAXIMUM VISIBLE GLASS138-1/2” X 138-1/2” NOT TO EXCEED 7574 SQ. IN.120 MINUTE MAXIMUM VISIBLE GLASS 126” X 126” NOT TO EXCEED 4536 SQ. IN.
12. MAXIMUM FRAME SIZE NOT LIMITED. ASSEMBLY ISCONSIDERED A WALL.
13. PRODUCT IS NOT LOAD BEARING. ADDITIONALBUILDING DESIGN FEATURES MAY BE REQUIRED FORUNITS OVER 12’ TALL.
14. CENTER GLAZED FRAMES NOT AVAILABLE.
2 916"
[65mm]
234"
[70mm]1316"
[20mm]
118"
[28mm]
11516"
[50mm]
38"
[10mm]
4 5 7 86
9
2
3
A HEAD DETAIL6"=1'-0"
2 916"
[65mm]
234"
[70mm]
1316"
[20mm]
11516"
[50mm]
38"
[10mm]4 5 7 86
9
2
13
D SILL DETAIL6"=1'-0"
118"
[28mm]
2 916"
[65mm]
234"
[70mm]
1316"
[20mm]11516"
[50mm]
38"
[10mm]
9
3
5
4
6
7
8
B JAMB DETAIL6"=1'-0"
118"
[28mm]
2
A HEAD DETAIL6"=1'-0"
C STRUCTURE JOINT6"=1'-0"
C STRUCTURE JOINT6"=1'-0"
4 516"
11516"
234"
38"
1316"
92 3
4 5 7 86
2 116"
[52mm]
B JAMB DETAIL6"=1'-0"
4 516"
11516"
234"
38"
[10mm]
1316"
9
2
35
4
6
7
8
2 116"
[52mm]
60 MINUTE RATING
120 MINUTE RATING
D SILL DETAIL6"=1'-0"
4 516"
11516"
234"
38"
1316"
9
2
3
4 5 7 86
12 116"
[52mm]
*NOTE: DUE TO GLASS TOLERANCE, SEALANT MAY BENEEDED TO HOLD ON VINYL GLAZING GASKET (PROVIDED ANDINSTALLED BY OTHERS).
MAY BE USED ON TRANSOMS AND SIDELIGHTS
BB C C BB C C
DD
A A
DD
A A
F20-16
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 60 Minute Interior Curtain Wall - Head and Sill DetailFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER, VARIES,2-13/16" SHOWN
2. E119 INTERIOR STEEL CURTAIN WALLVERTICAL MEMBER, VARIES,
2-13/16" SHOWN3. PRESSURE PLATE LOCKING SCREW
W/SPACER4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 60 GLAZING9. HORIZONTAL WEATHER STRIPPING WITH FIN10. FRAME ANCHOR PLATE11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
F20-17
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 60 Minute Interior Curtain Wall - Mullion DetailsFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER, VARIES,2-13/16" SHOWN
2. E119 INTERIOR STEEL CURTAIN WALLVERTICAL MEMBER, VARIES,2-13/16" SHOWN
3. PRESSURE PLATE LOCKING SCREWW/SPACER
4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 60 GLAZING9. HORIZONTAL WEATHER STRIPPING WITH FIN10. FRAME ANCHOR PLATE11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
F20-18
ASSA ABLOY, the global leader in door opening solutions
E119 60 Minute Interior Curtain Wall - Jamb DetailsFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER, VARIES,2-13/16" SHOWN
2. E119 INTERIOR STEEL CURTAIN WALLVERTICAL MEMBER, VARIES,2-13/16" SHOWN
3. PRESSURE PLATE LOCKING SCREWW/SPACER
4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 60 GLAZING9. HORIZONTAL WEATHER STRIPPING WITH FIN10. FRAME ANCHOR PLATE11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
March, 2019
F20-19
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 120 Minute Interior Curtain Wall - Head and Sill DetailsFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER2. E119 INTERIOR STEEL CURTAIN WALL
VERTICAL MEMBER3. PRESSURE PLATE LOCKING SCREW
W/SPACER4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 120 GLAZING9. HORIZONTAL WEATHER STRIPPING10. FRAME ANCHOR PLATE AT VERTICAL11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
F20-20
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 120 Minute Interior Curtain Wall - Mullion DetailsFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER2. E119 INTERIOR STEEL CURTAIN WALL
VERTICAL MEMBER3. PRESSURE PLATE LOCKING SCREW
W/SPACER4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 120 GLAZING9. HORIZONTAL WEATHER STRIPPING10. FRAME ANCHOR PLATE AT VERTICAL11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
F20-21
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 120 Minute Interior Curtain Wall - Jamb DetailsFire Resistive Products
NOTES:1. E119 INTERIOR STEEL CURTAIN WALL
HORIZONTAL MEMEBER2. E119 INTERIOR STEEL CURTAIN WALL
VERTICAL MEMBER3. PRESSURE PLATE LOCKING SCREW
W/SPACER4. SETTING BLOCK (BY OTHERS)5. SETTING BLOCK SHELF6. PRESSURE PLATES7. HORIZONTAL COVER CAP8. CONTRAFLAM 120 GLAZING9. HORIZONTAL WEATHER STRIPPING10. FRAME ANCHOR PLATE AT VERTICAL11. SHEAR LUG FOR VERTICAL PROFILE12. HARDWOOD BLOCK13. FINISH SEALANT (BY OTHERS)14. VERTICAL COVER CAP15. VERTICAL WEATHER STRIPPING17. INTUMESENT TAPE18. MINERAL WOOL (BY OTHERS)19. FIRE STOP & SMOKE SEAL (BY OTHERS)20. ANCHORS (BY OTHERS)
F20-22
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 Interior Curtain Wall 90O Inside CornerFire Resistive Products
F20-23
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 Interior Curtain Wall 90o Outside CornerFire Resistive Products
F20-24
ASSA ABLOY, the global leader in door opening solutions
E119 Interior Curtain Wall Inside Angled FrameFire Resistive ProductsMarch, 2019
F20-25
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 Interior Curtain Wall Back Mullion Options - 1-3/4" FaceFire Resistive Products
VA
RIE
S
12"
[12mm]D.L.O.
GLASS DIM.
34"
[19m
m]
215 16
" [7
5mm
]
1/16" [1.8 mm]
58"
[16m
m]
76.852
76.853
3916
" [9
0mm
]
1/16" [2 mm]
1/16" [1.8 mm]
76.854
4516
" [1
10m
m]
1/16" [2 mm]
76.855
518"
[130
mm
]
578"
[150
mm
]
134"
[45mm]
1/8" [3 mm]
76.856
PRESSURE PLATELOCKING SCREW
WEATHER STRIPPING
PRESSURE PLATE
CLAMPING FOOT
TEMPERATURE RISE GLAZINGSee Glazing options for moreinformation.
SPACER
FACING PROFILEAluminum 6060 T66, cold pressedStainless Steel 1.4301 ground with
grain 220-240, with protective adhesivefilm
F20-26
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 Interior Curtain Wall Back Mullion Options - 2-3/8" FaceFire Resistive Products
3916
" [9
0mm
]
4516
" [1
10m
m]51
8" [1
30m
m]
VA
RIE
S
238"
[60mm]
PRESSURE PLATELOCKING SCREW
WEATHER STRIPPING
PRESSURE PLATE
FACING PROFILEAluminum 6060 T66, cold pressedStainless Steel 1.4301 ground with
grain 220-240, with protectiveadhesive film.
578"
[150
mm
]
CLAMPING FOOT
TEMPERATURE RISE GLAZINGSee Glazing options for moreinformation.
316"
[4.5 mm]
1/16" [2 mm]
1/16" [2 mm]
1/16" [1.8 mm]
1316"
[20mm]D.L.O.
GLASS DIM.
76.863
76.864
76.865
76.866
SPACER
76.862
215 16
" [7
5mm
]
1/16" [1.8 mm]
58"
[16m
m]
34"
[19m
m]
F20-27
ASSA ABLOY, the global leader in door opening solutions
March, 2019
E119 Interior Curtain Wall Outside Angled FrameFire Resistive Products
F20-28
ASSA ABLOY, the global leader in door opening solutions
Narrow Stile Door Jamb Detail/Jamb Detail with Sidelight
March, 2019
NOTES:A. STEEL CURTAIN WALL HORIZONTAL MEMBERB. STEEL CURTAIN WALL VERTICAL MEMBERC. PRESSURE PLATE LOCKING SCREWD. SETTING BLOCK (BY OTHERS)E. SETTING BLOCK SHELFF. PRESSURE PLATESG. VERTICAL COVER CAPI. VEWRTICAL WEATHER STRIPPINGJ. SILL AND HEAD PLAT WITH SHEAR LUG AT
VERTICAL MULLIONK. HARDWOOD BLOCKL. ANCHOR (BY OTHERS)M. SHIM AS NECESSARY (BY OTHERS)N. FIRE STOP AND SMOKE SEAL (BY OTHERS)O. FIRE RESISTANT LOOSE INSULATION (BY OTHERS)P. FINISH SEALANT (BY OTHERS)Q. CLAMPING FOOTR. HINGE PER HARDWARE SCHEDULES. NARROW STILE 60/90 DOORT. DOOR ASSEMBLY FASTENER TO CURTAIN WALL
NOTE: ACTUAL ANCHORING MAY VARY PER PROJECT REQUIREMENTS. DRAWING FOR REFERENCE ONLY.
DOOR OPENING
3916"
[90mm]
14"
[6mm]
38"
[10mm]
11516"
[50mm]23
8" [60mm]
234"
[70mm]
FRAME WIDTH
ROUGH OPENING
D.L.O.
12"
[13mm]
2916
" [6
5mm
]
DOOR OPENING
3916"
[90mm]
38"
[10mm]
11516"
[50mm]23
8" [60mm]
FRAME DIMENSION
D.L.O.
2916
" [6
5mm
]
D.L.O.
VA
RIE
S3
9 16" -
57 8"
[90m
m -
150m
m]
R
P
N
B
14"
[6mm]
11516"
[50mm]
1316"
[20mm]
ROUGH OPENING
VA
RIE
S3
9 16" -
57 8"
[90m
m -
150m
m]
J
Q
O
F
C
G
H
S
P
N
O
P
N
OS
H
R
J
B
Q
H
F
C
G
I
I
K
L
K
A
L
T
T
JAMB DETAIL
JAMB DETAIL WITH SIDELIGHT
F20-29
ASSA ABLOY, the global leader in door opening solutions
March, 2019
Narrow Stile Door Meeting Edge Options
234"
[70mm]
112"
[38mm]23
4"[70mm]
916"
[14mm] 38"
[10mm]
38"
[10mm]
D.L.O.D.L.O.
DOOR OPENING
FRAME DIMENSION
2916
" [6
5mm
]
2916
" [6
5mm
]
7" [178mm]
PULL(HANDLE)
SIDE
PUSH(EXIT DEVICE)
SIDE
ROUGH OPENING
D.L.O.D.L.O.
DOOR OPENING
FRAME DIMENSION
578"
[150mm]
ROUGH OPENING
PULL(HANDLE)
SIDE
PUSH(EXIT DEVICE)
SIDE
F20-30
ASSA ABLOY, the global leader in door opening solutions
Narrow Stile Door Vertical Cross-SectionMarch, 2019
NOTES:A. STEEL CURTAIN WALL HORIZONTAL MEMBERB. STEEL CURTAIN WALL VERTICAL MEMBERC. PRESSURE PLATE LOCKING SCREWD. SETTING BLOCK (BY OTHERS)E. SETTING BLOCK SHELFF. PRESSURE PLATESG. HORIZONTAL COVER CAPI. HORIZONTAL WEATHER STRIPPINGJ. FRAME BASE PLATE AT VERTICALK. HARDWOOD BLOCKL. ANCHOR (BY OTHERS)M. SHIM AS NECESSARY (BY OTHERS)N. FIRE STOP AND SMOKE SEAL (BY OTHERS)O. FIRE RESISTANT LOOSE INSULATION (BY OTHERS)P. FINISH SEALANT (BY OTHERS)Q. CLAMPING FOOTR. HINGE PER HARDWARE SCHEDULES. NARROW STILE 60/90 DOORT. DOOR ASSEMBLY FASTENER TO CURTAIN WALL
38"
[10m
m]
10"
[254
mm
]
DO
OR
OP
EN
ING
2916"
[65mm]
38"
[10m
m]
115 16
" [5
0mm
]
1 4"[6
mm
]23
8" [6
0mm
]
VARIES
C
F
G
I
PULL(HANDLE)
SIDE
PUSH(EXIT DEVICE)
SIDE
P
A
FRA
ME
DIM
EN
SIO
N
3 916" - 57
8"[90mm - 150mm]
KE
Q
K
N
O
S
H
S
1 2" [1
3mm
]
OP
N
J
O
L
T
F20-31
ASSA ABLOY, the global leader in door opening solutions
March, 2019
Narrow Stile Door Vertical Cross-Section with Transom
NOTES:A. STEEL CURTAIN WALL HORIZONTAL MEMBERB. STEEL CURTAIN WALL VERTICAL MEMBERC. PRESSURE PLATE LOCKING SCREWD. SETTING BLOCK (BY OTHERS)E. SETTING BLOCK SHELFF. PRESSURE PLATESG. HORIZONTAL COVER CAPI. HORIZONTAL WEATHER STRIPPINGJ. FRAME BASE PLATE AT VERTICALK. HARDWOOD BLOCKL. ANCHOR (BY OTHERS)M. SHIM AS NECESSARY (BY OTHERS)N. FIRE STOP AND SMOKE SEAL (BY OTHERS)O. FIRE RESISTANT LOOSE INSULATION (BY OTHERS)P. FINISH SEALANT (BY OTHERS)Q. CLAMPING FOOTR. HINGE PER HARDWARE SCHEDULES. NARROW STILE 60/90 DOORT. DOOR ASSEMBLY FASTENER TO CURTAIN WALL
38"
[10m
m]
10"
[254
mm
]
2916"
[65mm]
38"
[10m
m]
115 16
" [5
0mm
]
1 4"[6
mm
]23
8" [6
0mm
] C
D
E
F
G
A
I
K
H
PULL(HANDLE)
SIDE
PUSH(EXIT DEVICE)
SIDE
P
DO
OR
OP
EN
ING
FRA
ME
DIM
EN
SIO
N
VARIES 3 916" - 57
8"[90mm - 150mm]
B
N
O
S
H
Q
T
F20-32