Date post: | 29-Nov-2014 |
Category: |
Engineering |
Upload: | adicomp-srl |
View: | 134 times |
Download: | 3 times |
VG Technical Datasheets for micro-turbine applications.
OIL-INJECTED ROTARY SCREW GAS COMPRESSORS AND TREATMENT SYSTEMS FOR DRY METHANE OR NATURAL GAS Capacity up to 3000Nm3/h Available discharge pressures from 5.5bar(g) to 6.6bar(g) Nominal power from 3.0 to 355kW
By working in partnership with Adicomp to secure your future
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
SPECIFICATION/MODEL U.M. VG3.0-6.0LD INV
VG4.0-6.0AD INV
VG5.5-6.0AD INV
VG7.5-6.0AG INV
VG9.0-6.0AG INV
VG11- 6.0BD INV
VG15-6.0CD INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C -10/40 -10/40 -10/40 -10/40 -10/40 -10/40 -10/40
GAS humidity type dry dry dry dry dry dry dry
Free Gas Delivery (min/max) m3/h 0 < 17 < 25 0 < 22 < 32 0 < 22 < 48 0 < 32 < 66 0 < 35 < 80 0 < 48 < 92 0 < 48 < 132
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 70 70 70 72 72 74 74
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 4.0 5.5 7.5 11 11 15 18.5
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 3000 3000 3000 1500 1500 3000 3000
Voltage V 400 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 7.6/6.3 10.8/8.5 13.4/11.3 21/14.1 21/21.5 26.5/21.5 32/27
Frequency Hz 50 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 85.8/81.5 87.8/83.1 88.1/84.2 89.8/86 89.8/87.6 90.3/87.6 90.9/88.7
Degree of protection IP 55 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS Nominal Power kW 0.25 0.25 0.25 0.25 0.37 0.37 0.37
Nominal speed rpm 3000 1500 3000 1500 1500 3000 3000
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 72.7 72.7 72.7 72.7 71.5 71.5 71.5
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 130 x 75 x 128
130 x 75 x 128
130 x 75 x 128
130 x 75 x 128
130 x 75 x 128
170 x 96 x 150
170 x 96 x 150
Connection In/Out RP/EN1092
1”1/4 - 3/4”
1”1/4 - 3/4”
1”1/4 - 3/4”
DN40 - 3/4”
DN40 - 3/4”
DN50 - 3/4”
DN50 - 3/4”
Noise level ±3% (OF) dB(A) 80 80 80 82 82 82 82
Nominal power (Ex de) zone 1 kW 3.0 4.0 5.5 7.5 11 11 15
Screw block rotation speed Rpm 2240 < 3600
1800 < 2570
1800 < 3560
2600 < 4900
3300 < 5900
1775 < 3320
1775 < 3200
Power absorbed kW 1.8 < 3.0 2.7 < 3.7 2.9 < 5.5 4.1 < 7.5 5.2 < 9.0 6.1 < 10.9 8.7 < 15.0
VG in accordance to ATEX95 or EN1127-1:2001 no-classified zones. (3.0kW-15kW)
2
www.adicomp.com
VG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
VG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (18.5kW-75kW)
SPECIFICATION/MODEL U.M. VG18.5-6.0CG INV
VG22-6.0CG INV
VG30-6.0HD INV
VG37-6.0DD INV
VG45-6.0DG INV
VG55-6.0MG INV
VG75-6.0MD INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C -10/40 -10/40 -10/40 -10/40 -10/40 -10/40 -10/40
GAS humidity type dry dry dry dry dry dry dry
Free Gas Delivery (min/max) m3/h 0 < 82 < 166
0 < 93 < 197
0 < 177 < 241
0 < 186 < 330
0 < 200 < 403
0 < 255 < 526
0 < 387 < 709
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 74 74 74 76 76 76 76
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 22 30 37 45 55 75 90
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 1500 1500 3000 3000 1500 1500 3000
Voltage V 400 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 41.5/35.5 55/41.5 65/54 79/65 98/81 132/99 153/130
Frequency Hz 50 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 91.6/89.3 92.3/89.9 92.5/90.7 92.9/91.1 93.5/91.7 94/92.1 94.1/92.7
Degree of protection IP 55 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS
Nominal Power kW 0.37 0.37 0.75 0.75 0.75 2.2 2.2
Nominal speed rpm 1500 1500 3000 3000 1500 1500 1500
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 71.5 71.5 79.6 79.6 79.6 84.4 84.4
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 170 x 96 x 150
170 x 96 x 150
220 x 120 x 185
220 x 120 x 185
220 x 120 x 185
220 x 120 x 185
220 x 120 x 85
Connection In/Out RP/EN1092
DN80 - 1”1/4
DN80 -1”1/4
DN80 -DN40
DN100 -DN40
DN100 -DN40
DN100 -DN50
DN100 - DN50
Noise level ±3% (OF) dB(A) 84 84 86 86 88 88 90
Nominal power (Ex de) zone 1 kW 18.5 22 30 37 45 55 75
Power absorbed kW 10.0 < 18.5 11.5 < 22.0 14.0 < 27.5 24.4 < 37.0 23.4 < 45.0 28.6 < 55.0 44.7 < 75.0
Screw block rotation speed Rpm 2100 < 3980
2370 < 4750
1775 < 3600
1927 < 3065
1850 < 3725
1170 < 2360
1775 < 3125
3
Copyright © 2014 Adicomp s.r.l. - All rights reserved - Rev. August 2014
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
4
www.adicomp.com
VG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (90kW-315kW)
SPECIFICATION/MODEL U.M. VG90- 6.0EG INV
VG110-6.0ED INV
VG132-6.0EG INV
VG160-6.0ND INV
VG200-6.0ND INV
VG250-6.0NG INV
VG315-6.0NG INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C -10/40 -10/40 -10/40 -10/40 -10/40 -10/40 -10/40
GAS humidity type dry dry dry dry dry dry dry
Free Gas Delivery (min/max) m3/h 0 < 404 < 841
0 < 647 < 1078
0 < 647 < 1204
0 < 662 < 1535
0 < 662 < 1885
0 < 1065 < 2350
0 < 1400 < 2850
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 78 78 78 78 80 80 80
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 110 132 160 200 250 315 355
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 1500 3000 1500 1500 1500 3000 3000
Voltage V 400 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 195/161 220/200 275/237 345/282 430/356 523/421 589/523
Frequency Hz 50 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 94.5/94 94.8/94.5 94.9/94.6 95.1/95.3 95.1/95.3 96.6/96.2 96.7/96.6
Degree of protection IP 55 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS
Nominal Power kW 2.2 2x 2.2 2x 2.2 2x 2.2 4x 3.0 4x 3.0 4x 3.0
Nominal speed rpm 1500 1500 1500 1500 1500 1500 1500
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 84.4 84.4 84.4 84.4 85.5 85.5 85.5
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 300 x 150 x 210
300 x 150 x 210
300 x 150 x 210
360 x 200 x 224
360 x 200 x 224
410 x 210 x 224
410 x 210 x 224
Connection In/Out RP/EN1092
DN150 - DN50
DN200 - DN80
DN200 - DN80
DN200 - DN80
DN250 - DN100
DN250 - DN100
DN300 - DN100
Noise level ±3% (OF) dB(A) 90 90 92 92 92 94 94
Nominal power (Ex de) zone 1 kW 90 110 132 160 200 250 315
Power absorbed kW 47.0 < 90.0 69.0 < 110.0
75.0 < 132.0
75.0 < 160.0
75.0 < 200.0
115.0 < 250.0
162.0 < 315.0
Screw block rotation speed Rpm 1160 < 2330
1800 < 2960
1800 < 3350 870 < 1943 870 < 2390 1390 <
2980 1775 < 3623
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
VG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
5
Copyright © 2014 Adicomp s.r.l. - All rights reserved - Rev. August 2014
———————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Download a QR Reader and scan the code to read this catalog on your tablet.
Adicomp s.r.l. via del Progresso, 35 - 36050 Sovizzo (Vicenza) Italy Ph. +39 0444 573979 - Fax +39 0444 809186 [email protected] - www.adicomp.com
(OF) - OPEN FRAME (STANDARD VERSION) Copyright © 2014 Adicomp s.r.l. – All rights reserved Datas are indicative and may be changed in any time without notice. Rev. August 2014