Page 1: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

TECHNICAL INFORMATION S2 Canister Vacuums

© 2012 Miele USA

Page 2: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

2

S2 Canister Vacuums

Table of Contents

A  Warning and Safety Instructions ....................................................................... 4 1  General Information .................................................................................................... 4 2  Cleaning and Care ...................................................................................................... 4 

2.1  Vacuums and Accessories ............................................................................. 4 2.2  Dust Compartment ......................................................................................... 4 

B  Modification History ............................................................................................ 5 C  Technical Data ..................................................................................................... 5 D  Layout of Electrical Components ...................................................................... 7 010  Casing Bottom, Motor ....................................................................................... 10 2  Function .................................................................................................................... 11 

2.1  Casters ......................................................................................................... 11 4  Service ...................................................................................................................... 11 

4.1  Caster Removal ............................................................................................ 11 4.2  Motor Removal ............................................................................................. 12 4.3  Cord Reel Removal ...................................................................................... 13 4.4  Cord Removal ............................................................................................... 14 

020  Casing Top ......................................................................................................... 17 2  Function .................................................................................................................... 18 

2.1  Bags ............................................................................................................. 18 2.2  Bag Change Indicator ................................................................................... 18 2.2  Filters ............................................................................................................ 19 

4  Service ...................................................................................................................... 19 4.1   Bag Holder Removal .................................................................................... 19 4.2   Bag Change Indicator Removal .................................................................... 19 4.3   Casing Top Removal .................................................................................... 20 4.4   Motor Protection Filter Frame Removal ........................................................ 21 4.5   Cover Frame Removal ................................................................................. 21 4.6   Air Inlet Regulator Removal .......................................................................... 23 4.7  Changing the Bag ......................................................................................... 23 4.8  Replacing the Super Air Clean Filter ............................................................ 24 4.9  Replacing the Active Air Clean or Active HEPA Filter ................................... 24 4.10  Replacing One Type of Filter with Another ................................................... 25 4.11  Changing the Dust Compartment (Motor Protection) Filter ........................... 25 

030  Controls, Electronic .......................................................................................... 26 2  Function .................................................................................................................... 27 

2.1  Suction Power .............................................................................................. 27 3  Fault Repair .............................................................................................................. 27 

3.1  Vacuum Cleaner Cannot Be Switched On .................................................... 27 3.2   Vacuum Cleaner Shuts Itself Off or Overheating Indicator LED Lights Up ... 28 

4  Service ...................................................................................................................... 28 4.1  Cap Removal ................................................................................................ 28 4.2  Electronic Removal ....................................................................................... 30 4.3   On/Off Switch Removal ................................................................................ 30 

040  Suction Hose, Accessories .............................................................................. 31 2  Function .................................................................................................................... 32 

Page 3: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

3

S2 Canister Vacuums

2.1  Accessories .................................................................................................. 32 3  Fault Repair .............................................................................................................. 32 

3.1  Suction Power Too Low ................................................................................ 32 4  Service ...................................................................................................................... 33 

4.1  Telescopic Suction Hose Locking Piece Replacement ................................. 33 4.2  Pushbutton Replacement (for Telescopic Hoses) ......................................... 34 

List of Figures Figure D-1: Control Panel (at Rear of Vacuum) ...................................................................... 7 Figure D-2: Internal Component Layout .................................................................................. 7 Figure D-3: External Component Layout (with Basic Suction Hose) ....................................... 8 Figure D-4: External Component Layout (with Electro Accessories) ....................................... 9 Figure 010-1: Support Roller and Axle .................................................................................. 11 Figure 010-2: Caster Removal .............................................................................................. 12 Figure 010-3: Electronic Retainer.......................................................................................... 12 Figure 010-4: Motor ............................................................................................................... 13 Figure 010-5: Cord Reel and Motor....................................................................................... 13 Figure 010-6: Cord Reel Retainer on Side ............................................................................ 14 Figure 010-7: Cord Reel, Unwound ....................................................................................... 14 Figure 010-8: Cord Reel Clamped to Reel Assembly Body .................................................. 15 Figure 010-9: Screws Securing Cord Reel ............................................................................ 15 Figure 010-10: Cord Reel Tabs ............................................................................................. 16 Figure 020-1: Bag Change Indicator ..................................................................................... 18 Figure 020-2: Filter Types ..................................................................................................... 19 Figure 020-3: Bag and Holder ............................................................................................... 19 Figure 020-4: Bag Change Indicator Removal ...................................................................... 20 Figure 020-5: Casing Top Removal ...................................................................................... 20 Figure 020-6: Filter Frame Retaining Tabs ........................................................................... 21 Figure 020-7: Cover Frame Screws ...................................................................................... 22 Figure 020-8: Cover Frame Removal .................................................................................... 22 Figure 020-9: Air Inlet Regulator ........................................................................................... 23 Figure 020-10: Changing the Bag ......................................................................................... 24 Figure 020-11: Replacing the Super Air Clean Filter ............................................................. 24 Figure 020-12: Replacing the Active Air Clean or Active HEPA Filter ................................... 25 Figure 020-13: Changing the Dust Compartment Filter ......................................................... 25 Figure 030-1: Rotary Selector Switch .................................................................................... 27 Figure 030-2: Cap Screws .................................................................................................... 29 Figure 030-3: Notches ........................................................................................................... 29 Figure 030-4: Tabs ................................................................................................................ 30 Figure 040-1: Accessories .................................................................................................... 32 Figure 040-2: Telescopic Locking Piece ............................................................................... 33 Figure 040-3: Pushbutton Replacement ................................................................................ 34  List of Tables Table C-1: S2 Data Sheet, US Models .................................................................................... 6 

Page 4: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

4

S2 Canister Vacuums

A Warning and Safety Instructions

1 General Information

All repairs should be performed by a trained technician in strict accordance with national, state and local codes. Any repairs or maintenance performed by unqualified personnel could be dangerous.

When servicing, modifying, testing or maintaining appliances, all applicord

laws, regulations and accident prevention guidelines must be observed.

All regulations of the appropriate utility supply companies and standards relating to safety (not limited to electrical safety) are to be complied with.

Before any service work is started, the vacuum cleaner must be

disconnected from the power supply. Even with the vacuum switched off, voltage may be applied to some components.

Do not leave the vacuum unattended when it is plugged in. Turn off and

unplug the vacuum before opening the cover.

After work has been completed, a visual as well as an operational check should always be performed.

2 Cleaning and Care 2.1 Vacuums and Accessories

The vacuum cleaner and other plastic components can be cleaned using a damp cloth or a cleaner made especially for plastics.

Warning! Do not use abrasive, glass or all-purpose cleaning solutions, as these can cause considerable damage to the plastic components of the vacuum or its accessories.

2.2 Dust Compartment The dust compartment can be cleaned using another vacuum, if available, or a dry cloth or brush.

Monitor the bag change indicator and inspect all filters regularly. Replace them when necessary according to the operating instructions.

Page 5: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

5

S2 Canister Vacuums

B Modification History

When? Who? What? 7/18/2012 Jessica Naples S 2121 (HomeCare) model info added

8/10/2011 Jessica Naples Cord reel troubleshooting and cord removal added

11/20/2009 Jessica Naples Conversion for Website 6/17/2008 Armin Mannert Initial compilation

C Technical Data

Model S 2110 S 2120 S 2121 S 2130 S 2180 Weight, without accessories 13.2 lbs (6kg)

Radius of operation

30' (9m)

Bag capacity 1.2 gal (4.5L)

Noise insulation Yes

Motor gentle start Yes

Suction power adjustment Rotary switch

On/off switch for Park System No

Bag type G/N

Super Air Clean filter Yes No

Active Air Clean filter No

Active HEPA filter No Optional No Yes

Bag change indicator Yes

Electric exhaust filter change indicator No

Overheating indicator light No

Blower function No

Filter grille Yes

Automatic cord rewind Yes

Page 6: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

6

S2 Canister Vacuums

Model S 2110 S 2120 S 2121 S 2130 S 2180 Accessories supplied

2 single connectable suction hoses (Easylock)

Model-dependent

2-part stainless-steel suction hose Model-dependent

3-part stainless-steel telescopic suction hose (TriScope)

Model-dependent

Electro-telescopic suction hose No Yes No

Suction hose holder Integrated

Suction hose connection Cylindrical stub

Universal floor attachment

SBD 350-3 SBD 470-3 SBD 450-3 SBD 350-3

Electrobrush/ Rechargeable electrobrush

Optional accessory SEB 228 Optional accessory

Turbo brush Optional accessory

Upholstery nozzle/ Dusting brush Yes/Yes

Crevice nozzle/ Extended crevice nozzle

Yes/No

Electrical connection - USA models only

Power rating 1200W

Voltage 120V

Fuse rating 15A

Power consumption 0.3 - 1.4 kWh Table C-1: S2 Data Sheet, US Models

Page 7: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

7

S2 Canister Vacuums

D Layout of Electrical Components

Figure D-1: Control Panel (at Rear of Vacuum)

Figure D-2: Internal Component Layout

1 Cord reel W16 2 Electronic 3 Main switch Q1 4 Motor

Page 8: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

8

S2 Canister Vacuums

Figure D-3: External Component Layout (with Basic Suction Hose)

1 Handle 13 Bag 2 Air inlet valve 14 Motor protection filter 3 Release button 15 Exhaust filter (model-dependent) 4 Easylock suction hose 16 On/off footswitch 5 Adjustment knob for telescopic

suction hose(model-dependent) 17 Park System

6 Connection receptacle 18 Power cord 7 Suction hose (model-dependent) 19 Footswitch for automatic cord rewind 8 Telescopic suction hose

(model-dependent) 20 Bag change indicator

9 Release button for dust compartment cover

21 Accessory holder for 3 accessories

10 Suction power regulator 22 Suction hose 11 Floor attachment Not shown Suction hose holder (on underside of

appliance) 12 Carrying handle

Page 9: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

9

S2 Canister Vacuums

Figure D-4: External Component Layout (with Electro Accessories)

1 Handle 12 Socket for electro accessories 2 On/off switch for electrobrush 13 Bag 3 Lock release button 14 Motor protection filter 4 Electro-telescopic wand 15 Exhaust filter (model-dependent) 5 Elbow 16 On/off footswitch 6 Plug for electro accessories 17 Park System 7 Electro telescopic wand release button 18 Power cord 8 Release button for dust compartment cover 19 Footswitch for automatic cord rewind 9 Suction power regulator 20 Bag change indicator

10 Electrobrush 21 Accessory holder for 3 accessories 11 Carrying handle 22 Suction hose SES 116

Page 10: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

10

S2 Canister Vacuums

010 Casing Bottom, Motor

Page 11: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

11

S2 Canister Vacuums

2 Function 2.1 Casters

The appliance has three casters that can rotate through 360°. The caster rollers are mounted on steel axles. The roller contact surfaces are covered with a soft plastic coating.

4 Service 4.1 Caster Removal

1. Lever out the support roller and axle with a flathead screwdriver. See Figure 010-1.

Figure 010-1: Support Roller and Axle

2. Lever out the caster; see Figure 010-2.

Page 12: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

12

S2 Canister Vacuums

Figure 010-2: Caster Removal

4.2 Motor Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the cap. See Section 030-4.1. 3. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,

Figure 010-3, Item 2.

Figure 010-3: Electronic Retainer

4. Remove the cover frame; see Section 020-4.5. 5. Lift the motor (Figure 010-4, Item 1) up and out of the appliance. 6. Disconnect the connection to the cord reel.

Page 13: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

13

S2 Canister Vacuums

Figure 010-4: Motor

Note: When re-installing, the rubber seal must first be installed in the cover frame.

4.3 Cord Reel Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the cap. See Section 030-4.1. 3. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,

Figure 010-3, Item 2. 4. Remove the cover frame; see Section 020-4.5. 5. Disconnect the cord reel (Figure 010-5, Item 1) from the motor (Figure

010-5, Item 2).

Figure 010-5: Cord Reel and Motor

6. Free the cord reel assembly from its retainers (Figure 010-5, Item 3, and Figure 010-6, Item 1).

Page 14: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

14

S2 Canister Vacuums

Figure 010-6: Cord Reel Retainer on Side

7. Disconnect the cord reel from the electronic. 8. Release all wires from their guides. 9. Remove the electronic retainer.

4.4 Cord Removal Note: Use only a genuine Miele cord for the correct vacuum model number.

Note: Never replace the cord end.

1. Remove the cord reel. See Section 010-4.3. 2. Unwind the cord completely. See Figure 010-7.

Figure 010-7: Cord Reel, Unwound

Page 15: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

15

S2 Canister Vacuums

3. Clamp the cord reel to the body of the cord reel assembly to immobilize it. See Figure 010-8. Failure to clamp the cord reel can allow it to rotate, changing the spring tension and affecting operation. The reel can also separate from the body, releasing the tension spring. Always clamp the reel to the body before performing any cord repair.

Figure 010-8: Cord Reel Clamped to Reel Assembly Body

4. Once the clamp is in place, remove the 2 T10 screws from the cord reel. See Figure 010-9.

Figure 010-9: Screws Securing Cord Reel

5. Release the tabs holding the two halves of the cord reel together. See Figure 010-10. The top of the reel will lift straight up.

Page 16: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

16

S2 Canister Vacuums

Figure 010-10: Cord Reel Tabs

6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble the reel halves. Do not remove the clamp until the cord reel

halves are fully assembled. 9. When the reel has been reassembled, remove the clamp and retract the

cord slowly, leaving a 6” tail. Once the cord reel is installed in the vacuum it is important to do an operational check and ensure that the cord extends and retracts correctly.

Page 17: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

17

S2 Canister Vacuums

020 Casing Top

Page 18: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

18

S2 Canister Vacuums

2 Function 2.1 Bags

A clean bag is essential to the maximum efficiency of the vacuum. A clogged bag can cause restricted airflow resulting in poor suction or, in extreme cases, an overheat condition can occur resulting in the vacuum shutting off. Changing the bag is relatively easy; the most important thing to remember is to use the correct bag. A list of bags and the models in which they are used can be found in the product line information in the operating manual.

2.2 Bag Change Indicator

Figure 020-1: Bag Change Indicator

To test the bag change indicator:

1. Connect the floor attachment to the suction hose. 2. Switch on the vacuum cleaner. 3. Set the selector to full power. 4. Lift the floor attachment from the floor. If the window in the bag change

indicator is completely red, then the bag must be changed. See Section 020-4.7 for instructions.

The display function is set for mixed dust (dust, hairs, threads, carpet fluff, sand, etc.).

If large quantities of fine dust (e.g., from drilling holes in masonry, fine sand, etc.) are vacuumed, the bag pores are quickly blocked. The bag change indicator then indicates “full” even though it is not actually full. However, the bag should still be replaced.

If large quantities of hair, carpet fluff, etc., are vacuumed, the indicator might not react until the bag is stuffed full.

Page 19: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

19

S2 Canister Vacuums

2.2 Filters Miele canister vacuums use several types of filters (Super Air Clean, Active Air Clean, Active HEPA) to provide a clean, healthy environment. See Figure 020-2. Vacuum model will dictate filter(s) type. See Table C-1.

Figure 020-2: Filter Types

Note: Changing from one type of filter to another type is permitted. (e.g., Active Air Clean to Active HEPA). See Section 020-4.10 for instructions.

4 Service

4.1 Bag Holder Removal 1. Open the casing top wide. 2. Remove the bag (Figure 020-3, Item 1). 3. Press the holder (Figure 020-3, Item 2) downwards on one side. 4. Remove the holder from its guide.

Figure 020-3: Bag and Holder

4.2 Bag Change Indicator Removal 1. Open the casing top. 2. Lever the bag change indicator from its guide using a small flathead

screwdriver; see Figure 020-4.

a Super Air Clean b Active Air Clean c Active HEPA (High Efficiency Particulate Air)

Page 20: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

20

S2 Canister Vacuums

Figure 020-4: Bag Change Indicator Removal

4.3 Casing Top Removal 1. Open the casing top wide. 2. Lever out the hinge arms, Figure 020-5.

Figure 020-5: Casing Top Removal

Page 21: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

21

S2 Canister Vacuums

4.4 Motor Protection Filter Frame Removal 1. Open the casing top wide. 2. Remove the bag. 3. Release the frame retaining tabs with a suitable tool; see Figure 020-6,

Item 1. 4. Remove the frame.

Note: If it is too difficult to release the tabs from the top, open the frame, insert the flathead screwdriver behind it and pry it out.

Figure 020-6: Filter Frame Retaining Tabs

Note: When re-installing, insert the top of the frame first.

4.5 Cover Frame Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the exhaust filter. 3. Remove the cap. See Section 030-4.1. 4. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,

Figure 010-3, Item 2. 5. Remove the bag holder; see Section 020-4.1. 6. Remove the six cover frame retaining screws (T20); see Figure 020-7,

Item 1.

Page 22: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

22

S2 Canister Vacuums

Figure 020-7: Cover Frame Screws

7. Hold the base firmly with one hand by pressing down at Figure 020-8, Item 2. Grasp inside the cover frame at Figure 020-8, Item 3, and pull straight up, about ¼ to ½ inch, until the handle locking tabs disengage (audible click).

8. Release the cord reel retainer, Figure 020-8, Item 1, and then remove the cover frame.

Figure 020-8: Cover Frame Removal

Note: When re-installing, install the front and rear screws first, then the side screws.

Page 23: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

23

S2 Canister Vacuums

4.6 Air Inlet Regulator Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the cap. See Section 030-4.1. 3. Remove the cover frame. See Section 020-4.5. 4. Turn the cover frame over. 5. Remove the air inlet regulator; see Figure 020-9, Item 1.

Figure 020-9: Air Inlet Regulator

4.7 Changing the Bag

1. Open the lid. 2. Pull the bag out by the grip next to the self-closing flap on the collar

(Figure 020-10, Item 1). 3. Discard the full bag in a suitable container (trash can). 4. Remove the NEW bag from the box. DO NOT UNFOLD IT. 5. Slide the new bag into the holder as far as it will go (Figure 020-10, Item 2). 6. Close the lid, making sure that it clicks into place.

Note: The lid will not close without a bag in place, or if the bag is inserted incorrectly. Do not force it.

Page 24: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

24

S2 Canister Vacuums

Figure 020-10: Changing the Bag

4.8 Replacing the Super Air Clean Filter 1. Open the dust compartment lid. 2. Unclip the filter grill and raise it up. 3. Carefully grasp the used filter at a clean, UNSOILED section (see arrow)

and remove (Figure 020-11, Item 1). 4. Replace with a new filter. It can be inserted either side up. 5. Close the filter grill and and snap it back into place. 6. Close the dust compartment lid.

Figure 020-11: Replacing the Super Air Clean Filter

4.9 Replacing the Active Air Clean or Active HEPA Filter 1. Open the dust compartment lid. 2. Lift out the old exhaust filter (Figure 020-12, Item 1). 3. Replace it with the new filter (Figure 020-12, Item 2). 4. Close the dust compartment lid.

Page 25: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

25

S2 Canister Vacuums

Figure 020-12: Replacing the Active Air Clean or Active HEPA Filter

4.10 Replacing One Type of Filter with Another

If you wish to replace the SUPER AIR CLEAN FILTER with the ACTIVE AIR CLEAN FILTER or the ACTIVE HEPA FILTER, you MUST REMOVE the grill BEFORE inserting the new type of filter.

If you wish to replace the ACTIVE AIR CLEAN FILTER or the ACTIVE HEPA FILTER with the SUPER CLEAN FILTER then you MUST ALSO INSERT the grill.

The ACTIVE AIR CLEAN FILTER can be used instead of the ACTIVE HEPA FILTER, or vice versa, without any changes.

4.11 Changing the Dust Compartment (Motor Protection) Filter

Replace the dust compartment filter every time a new box of bags is started.

1. Open the dust compartment lid. 2. Unclip the filter frame, remove the old filter (Figure 020-13, Item 1) and

replace it with a new one (Figure 020-13, Item 2). 3. Close the filter frame. 4. Close the dust compartment lid.

Figure 020-13: Changing the Dust Compartment Filter

Page 26: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

26

S2 Canister Vacuums

030 Controls, Electronic

Page 27: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

27

S2 Canister Vacuums

2 Function 2.1 Suction Power

Figure 030-1: Rotary Selector Switch

The suction power is set via the rotary selector switch as appropriate for the surface to be vacuumed:

: Curtains and textiles : Upholstery, cushions : High-quality carpets, rugs and runners

: Energy saving, everyday vacuuming with reduced noise level : Lightly soiled carpets and soft floors : Hard floors, heavily soiled carpets and soft floors

For more information, see the general DTD.

3 Fault Repair

3.1 Vacuum Cleaner Cannot Be Switched On Cause: On/off switch faulty. Remedy: 1. Remove the electronic; see Section 030-4.2. 2. Check the switch contacts for continuity. 3. If continuity does not exist, replace the on/off switch. See On/Off Switch

Replacement, Section 030-4.3.

Cause: 1. Faulty cord reel. 2. Faulty cord. Remedy: 1. Remove the cord reel; see Section 010-4.3. 2. Check for voltage on the back of the cord reel (between terminals L and

Page 28: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

28

S2 Canister Vacuums

N). Voltage reading should be 120VAC +/- 10 volts. 3. If cord reel voltage is faulty (or nonexistent), then the cord reel is

defective. Replace it with a new one, following the instructions in Section 010-4.3.

4. If cord reel voltage is correct, then check voltage at the cord. Measure between the black and white wires on the front of the cord reel (visible through the “window”). Voltage reading should be 120VAC +/- 10 volts.

5. If cord voltage is faulty (or nonexistent), then the cord is defective. Replace it with a new one, following the instructions in Section 010-4.4.

3.2 Vacuum Cleaner Shuts Itself Off or Overheating Indicator LED

Lights Up Cause: The motor has overheated and the thermostat has tripped. Remedy: 1. Switch off the appliance. 2. Disconnect the power cord. 3. Identify the cause of overheating and rectify it.

Note: Possible fault causes:

Bag is full or fine dust has made it non-porous. Motor protection or exhaust filter severely soiled. Suction hose blocked.

Possible remedies: Change bag. Change motor protection or exhaust filter. Clear any obstructions in the suction hose.

After the problem has been rectified, the vacuum cleaner must be allowed to cool for approximately 30 minutes. It can then be used again.

4 Service 4.1 Cap Removal

1. Remove the casing top; see Section 020-4.3. 2. Remove the exhaust filter. 3. Turn the rotary switch counterclockwise as far as possible. 4. Remove the two retaining screws (T20); see Figure 030-2, Item 1.

Page 29: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

29

S2 Canister Vacuums

Figure 030-2: Cap Screws

5. Press a suitable tool into the recess under the left and right footswitches next to the Park System (Figure 030-3, Item 1). Pull up at Figure 030-3, Item 2, to release the retaining tabs (Figure 030-4, Item 1).

6. Remove the cap upwards.

Figure 030-3: Notches

Page 30: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

30

S2 Canister Vacuums

Figure 030-4: Tabs

4.2 Electronic Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the cap. See Section 030-4.1. 3. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,

Figure 010-3, Item 2. 4. Remove the cover frame; see Section 020-4.5. 5. Remove the cord reel. See Section 010-4.3. 6. Disconnect all connections from the electronic. 7. Remove the electronic from its retainer.

4.3 On/Off Switch Removal 1. Remove the casing top. See Section 020-4.3. 2. Remove the cap. See Section 030-4.1. 3. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,

Figure 010-3, Item 2. 4. Remove the on/off switch from its holder using a suitable tool. 5. Disconnect the plug connections.

Page 31: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

31

S2 Canister Vacuums

040 Suction Hose, Accessories

Page 32: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

32

S2 Canister Vacuums

2 Function 2.1 Accessories

Figure 040-1: Accessories

The accessory holder can either be clipped in position on the connection stub or the handle connection sleeve.

For more information, see the operating instructions or the general DTD.

3 Fault Repair 3.1 Suction Power Too Low

Cause: Floor attachment or suction hose blocked. Remedy: Clean the floor attachment or suction hose.

Cause: Bag full. Remedy: Change the bag.

Note: If the window in the bag change indicator is completely red, then the bag must be changed.

Cause: Motor protection filter clogged. Remedy: Replace the motor protection filter.

1 Dusting brush 2 Upholstery brush 3 Crevice nozzle 4 Accessory holder

Page 33: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

33

S2 Canister Vacuums

Note: The motor protection filter should always be changed when a new pack of Miele vacuum bags is opened. A motor protection filter is supplied with every pack of Miele vacuum bags.

Cause: Exhaust filter clogged. Remedy: Replace the exhaust filter.

Note: 1. Super Air Clean This exhaust filter should always be changed when a new pack of Miele vacuum bags is opened. A Super Air Clean exhaust filter is supplied with every pack of Miele vacuum bags. 2. Active Air Clean - Active HEPA This exhaust filter must be changed after approximately 1 year. The date can be written on the filter.

4 Service

4.1 Telescopic Suction Hose Locking Piece Replacement 1. Release the old locking piece with a small flathead screwdriver. 2. Remove the cap (Figure 040-2, Item A). The pushbutton and spring

underneath will be released as well. 3. The insert (Figure 040-2, Item B) will also come out when the locking

piece is removed.

Figure 040-2: Telescopic Locking Piece

Note: When re-installing, carry out the following in the given order: 1. Install the pushbutton, Figure 040-2, Item A. 2. Press and hold the pushbutton while sliding the insert (Figure 040-2, Item

B) into the suction hose.

The insert can be replaced separately, if needed.

Page 34: TECHNICAL INFORMATION S2 Canister Vacuums...2013/04/17  · S2 Canister Vacuums Figure 010-10: Cord Reel Tabs 6. Remove the cord from the cord reel. 7. Install the new cord. 8. Reassemble

Technical Information

34

S2 Canister Vacuums

4.2 Pushbutton Replacement (for Telescopic Hoses) 1. Pry off the old pushbutton with a small flathead screwdriver. 2. Place the bar, Figure 040-3, Item D, in its holder. 3. Place the spring, Figure 040-3, Item A, in its holder. 4. Place the pushbutton, Figure 040-3, Item B, on the bar. 5. Push the housing, Figure 040-3, Item C, into position. 6. Check for correct function.

Figure 040-3: Pushbutton Replacement


Recommended