Effect of Plan Distribution of Energy Dissipation Devices on Seismic Response of Soft-Story Wood-Framed Structures. Jingjing Tian , Ph.D. Student Michael D. Symans , Assoc. Professor Dept. of Civil and Environmental Engineering Rensselaer Polytechnic Institute. - PowerPoint PPT Presentation
20
Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012 Jingjing Tian, Ph.D. Student Michael D. Symans, Assoc. Professor Dept. of Civil and Environmental Engineering Rensselaer Polytechnic Institute Effect of Plan Distribution of Energy Dissipation Devices on Seismic Response of Soft-Story Wood-Framed Structures 1
Transcript
Page 1: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

1

Technical Session 10 (Wood Structures)2012 Quake Summit

Boston, MAJuly 12, 2012

Jingjing Tian, Ph.D. Student

Michael D. Symans, Assoc. Professor

Dept. of Civil and Environmental EngineeringRensselaer Polytechnic Institute

Effect of Plan Distribution of Energy Dissipation Devices on Seismic Response of

Soft-Story Wood-Framed Structures

Page 2: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

2

NEESR-CR: NEES-Soft: Seismic Risk Reduction for Soft-Story Wood Frame Buildings

John W. van de Lindt University of Alabama PI, Overall Project Manager

Michael Symans Rensselaer Polytechnic Institute

Co-PI, Performance-Based Seismic Retrofit

Weichiang Pang Clemson University Co-PI , Advanced Numerical Modeling

Mikhail Gershfeld Cal State University, Pomona Co-PI, Design of Test Specimens

Xiaoyun Shao Civil EngineeringWestern Michigan Univ. Co-PI, Hybrid Test Coordinator

Andrei Filiatrault University at Buffalo Senior Personnel

David Rosowsky Rensselaer Polytechnic Institute Senior Personnel

Gary Mochizuki Structural Solutions, Inc. Senior PersonnelIoannis

ChristovasilisNational Tech. Univ. of

Athens Senior Personnel

Douglas Rammer U.S. Forest Products Lab Senior PersonnelDavid Mar Tipping Mar Senior Personnel

Research supported by National Science Foundation CMMI Grant No. 1041631 (NEESR - Network for Earthquake Engineering Simulation Research)

Project Team

Page 3: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

3

Outline• Seismic response and energy dissipation retrofit for soft-story buildings

• Energy dissipation retrofit• Damper type and location• Displacement amplification system

• Numerical Simulations• Summary of parametric study of linear

simplified model• Nonlinear analysis of simplified model

• Summary and Future work

Page 4: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

4

Seismic Response of Soft-Story BuildingsSoft-Story Buildings:- Stiffness irregularity due to first story having large openings in perimeter walls and minimal interior walls and upper stories having small openings and many interior walls. - First story acts as a base isolation system in that it protects the upper stories through its flexibility.

Page 5: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

5

Seismic Retrofit Strategies

• Conventional Retrofit• Increase stiffness/strength of soft story• Tends to increase forces transmitted to upper stories• Thus, need to avoid overstrengthening soft story• Expected performance level for design earthquake:

Shelter-in-Place (structure serves as shelter but may have significant damage)

• Performance-Based Retrofit• Increase damping in first story (and possibly stiffness)• May increase force transmitted to upper stories• Expected performance level for design earthquake:

Fully Operational (FO) to Immediate Occupancy (IO)

Page 6: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

6

Energy Dissipation Retrofit• Damper Type• Linear fluid viscous dampers• Linear: Peak force out-of-phase with peak displ.• Pure energy dissipation• Design and analysis procedures exist• Previously tested in wood structures

• Damper Location• First story only• Perimeter walls to increase torsion resistance• Along both stiff and flexible wall lines• Displacement amplification system (scissor-jack)

Page 7: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

7

Damper Displacement Amplification System:Scissor-Jack Bracing

Scissor-jack bracing assembly in "Olympic House and Park Building"

in Nicosia, Cyprus

Fluid Viscous Damper

Model of FVD within scissor-jack bracing

Simplified Model- Neglect flexibility of bracing members- Neglect damper stiffness- Result: Amplification factor = 4 (based on geometry of narrow garage door walls used in soft story building model)

Source: Hanson and Soong (2001)

Page 8: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

8

Numerical Simulations

• One-Story Elastic Structure (Review of Main Findings)– Two-way asymmetric – Linear elastic shear walls; Linear viscous dampers– Uniaxial and biaxial ground motions– Parametric Study (using Matlab) to evaluate effects of damping plan

distribution and damping magnitude

• One-Story Inelastic Structure– Two-way asymmetric – Nonlinear shear walls; Linear viscous dampers– Uniaxial and biaxial ground motions– Parametric Study (using SAWS2.1 + SAWS2.1-IDA) to evaluate effects of

damping plan distribution and damping magnitude

Page 9: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

9

CM = Center of Mass

CR = Center of Rigidity (located at ; similar to location for NEES-Soft test specimen)

CSD = Center of Supplemental Damping (location varies)

/ 0.2 and / 0.2x ye a e d

EQ-X

Parametric Study of One-Story Linear Elastic Structure with Energy Dissipation System- Two-way asymmetric w/rigid diaphragm- Uniaxial ground motion- CR & CM Fixed- CSD Varied

Since a damping system isadded to the inherent damping (5% assumed in all modes) with intent of protecting structural framing system, structure behavior is assumed to be linear elastic.

Northridge EQ Motions- Rinaldi Receiving Station (strong near-field)- Newhall County Fire Station (moderate near-field)- Canoga Park Station (moderate far-field)

Rigi

d-Ed

ge

Flex

ible

-Edg

e

Page 10: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

10EQ-X

Flexible-Edge Deformation Rigid-Edge Deformation

10%sdx sdy

Effect of Plan Distribution onMax. Inter-story Drift

- One-story elastic structure (Tnx = Tny = 0.5 sec)- Uniaxial ground motion (Rinaldi 228)- Drift normalized w.r.t. value when CSD is at CR- Fixed damping magnitude:

CSD @

Rigid Edge

CSD @

Flexible Edge

Moving CSD away from CR and toward CM:- Reduces drift along flexible edge (minimizes translation AND torsion).- Increases drift along rigid edge but rigid edge drift not main concern.- Overall, plan-wise distribution of damping has strong influence on structure response

Page 11: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

11

Effect of Damper Magnitude on Max. Inter-story Drift / 0.5

/ 0.5sdx

sdy

e ae d

- One-story elastic structure- Uniaxial ground motion (CP 106)- Drift normalized w.r.t. value when- Fixed CSD:

EQ-X

Increasing Magnitude of Damping:- Monotonically reduces drift along both flexible and rigid edges (minimizes translation AND torsion).- Strongest influence is on flexible edge- Rate of drift reduction largest for small damping ratios.- Transmission of damper forces to wood framing system and into foundation may impose limitation on damper magnitude.

10%sdx sdy

0% 30%sdx sdy

Rigid-Edge

Flexible-Edge

Flexible and Rigid Edge Deformations

Page 12: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

12

Parametric Study of One-Story Inelastic Structure with Energy Dissipation System - Two-way asymmetric w/rigid diaphragm- Uniaxial ground motion- CR & CM Fixed- CSD Varied

Northridge EQ Motions- Newhall County Fire Station: NCF90+NCF360 (moderate near-field)- Canoga Park Station: CP106+CP196 (moderate far-field)

CM = Center of Mass

CR = Center of Rigidity (located at ; similar to location for NEES-Soft test specimen).

CSD = Center of Supplemental Damping (location varies in Y- direction).

/ 0.2 and / 0.2x ye a e d

EQ-X

- 4 walls (one on each side)- 2 dampers along X- direction, (one each on north and south sides)- Wall materials: Exterior: Horiz. wood sheathing Interior: Gypsum wall board

SAWS Shear Wall Model:Hysteretic responseof conventional structure (no dampers)subjected to bi-axial Canoga Park motion.

Page 13: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

13

CSD moving

- One-story inelastic structure (Tnx = Tny = 0.5 sec)- Uniaxial ground motion (CP106)- Fixed total damping magnitude: Damping coefficient along X- direction is 5 kips-sec/in

Moving CSD from flexible edge to stiff edge:- Increases drift along flexible edge (due to both translation AND torsion).- Reduces drift along stiff edge.- Overall, damper location (plan-wise distribution) has strong influence on structure response.- The optimized CSD location is approximately -0.2d in Y- direction (for a range of motions).

CSD

mov

ing

/ 0.5sdxe a / 0.5sdxe a

/ 0.5sdye d

/ 0.5sdye d

Effect of Plan Distribution on Max. Inter-Story Drift

EQ-X

Page 14: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

14

Effect of Damper Magnitudeon Max. Inter-Story Drift

- One-story inelastic structure- Uniaxial ground motion (CP 106)- Damper magnitude for both dampers increased at same rate from 0 to 5 kips-sec/in.- CSD location fixed ( ).

Increasing Magnitude of Damping:- Monotonically reduces drift along all wall lines (minimizes both translation AND torsion). Rate of drift reduction largest at small damper magnitudes.- Transmission of damper forces to wood framing system and into foundation may impose limitation on damper magnitude.

0.2sdye d

/ 0.5sdye d

/ 0.5sdye d

EQ-X

Page 15: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

15

Parametric Study of One-Story Inelastic Structure with Energy Dissipation System- Two-way asymmetric w/rigid diaphragm- Biaxial ground motion- CR and CM Fixed- CSD varies

EQ Motions- Canoga Park Station (moderate far-field)- 22 Far-field EQ records from ATC-63- Stronger component applied in X-direction

CM = Center of MassCR = Center of Rigidity (located at ; similar

to location for NEES-Soft test specimen)CSD = Center of Supplemental Damping (location varies in X- and Y-direction).

/ 0.2 and / 0.2x ye a e d

EQ-X

EQ-Y

- 4 walls (one on each side)- 2 dampers along X- direction, (one each on north and south sides)- 2 dampers along Y- direction, (one each on west and east sides)- Wall materials: Exterior: Horiz. wood sheathing Interior: Gypsum wall board

SAWS Shear Wall Model:Hysteretic responseof conventional structure (no dampers)subjected to bi-axial Canoga Park motion.

Page 16: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

16

- One-story inelastic structure (Tnx = Tny = 0.5 sec)- Biaxial ground motion (CP106+CP196)- Fixed total damping magnitude: Damping coefficient along each direction is 5 kips-sec/in

Moving CSD from CR towards, and beyond, CM:- The maximum structural responses generally decreases (reducing translation AND torsion).- Damper location (plan-wise distribution) has strong influence on structure response.- For a range of ground motions, the optimized CSD location is approximately at the coordinate (0.2, -0.2), which is symmetric with CR about CM.

CR

CM

CSD @

Stiff Edge

CSD @

Flexible Edge

CSD @Flexible Edge CSD @ Stiff Edge

Conventional

0.77 (0.2,-0.2)

Effect of Plan Distribution on Max. Inter-Story Drift

Page 17: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

17

- One-story inelastic structure (Tnx = Tny = 0.5 sec)- Biaxial ground motion (22 far-field records)- Fixed damping magnitude: damping coefficient along each direction is 2.5 kips-sec/in

Moving CSD from CR towards CM:- Maximum drift varies non-monotonically.- Damper location (plan-wise distribution) has strong influence on structure response.- Optimized CSD location: X = 0.1~0.2 Y = -0.2~-0.1

CSD location (x,-0.2) CSD location (0.2,y)

CSD moving in X

CSD

mov

ing

in Y

CSD moving in X CSD moving in Y

Effect of Plan Distribution on Max. Inter-Story Drift: Far-Field Ground Motions

Page 18: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

18

Summary/ConclusionsGeneral Conclusion

Plan distribution of energy dissipation system (location of CSD) has strong influence on maximum inter-story drift response of both linear and nonlinear soft-story structures.

Linear Elastic StructureMinimum inter-story drift of flexible wall lines (critical walls) obtainedwhen CSD is as far as possible from CR in direction toward CM (ideally, at corner of structure, although damping cannot physically be concentrated at a single point).

Nonlinear Structure- Minimum inter-story drift of flexible wall lines (critical walls)

obtained when CSD is far from CR in direction toward CM but NOT as far as possible.

- Near-optimal choice for plan distribution of dampers is to position them such that the CSD is symmetric with respect to the CR about the CM.

Page 19: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

19

Numerical- Extend parametric analyses to multi-story inelastic structures with different wall materials (SAWS2.1/SAWS2.1-IDA/Matlab)- Extend analyses to consider near-field ground motions- Investigate seismic retrofit consisting of combined stiffening and damping

Numerical/Experimental- Evaluate performance of damper/stiffening retrofit relative to conventional

(primarily stiffening) retrofits

Experimental- Real-time hybrid testing of full-scale shear walls with dampers at

University of Alabama- Hybrid testing of 3-story full-scale building using virtual dampers at NEES-UB- Shake table testing of 4-story full-scale building using physical dampers

at NEES-UCSD

On-Going/Future Work

Page 20: Technical Session 10 (Wood Structures) 2012 Quake Summit Boston, MA July 12, 2012

20

QUESTIONS?