Page 1: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

180 HAMERSLEY ROAD SUBIACO WA 6008

PLEASE DIRECT ALL TECHNICAL ENQUIRIES TO THE TECHNICAL MANAGER:

TROY WILLIAMS T: +61 8 9380 3003 F: +61 8 9380 3030E: [email protected]

Page 2: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

1Updated 12 May 2017

STAGEBRIEF STAGE DESCRIPTION

Unraked corner thrust stage with motorized stage lighting grid. Upstage entrance OP. Crossover access is underneath seating area and via the dressing room. Hardwood floor covered Masonite sheets.

MAIN AUDITORIUM

Raked seating on three sides. With one foyer entrance for audience members

Seating capacity 305

Stage rake No

STAGE DIMENSIONS

The stage is asymmetrical and does not have wings and has minimal capacity for movement of props, set and instruments on and off stage. With 3 banks of audience seats around, it approximately fits inside a diamond. For more details request a stage plan.

Approx. stage size: 9180mm x 7410mm

Stage to underside of grid 4300mm

STAGE TRAPS

Motorized Grid frame over stage floor. Picked up by 4 chain motors.

FLYING FACILITIESFLY SYSTEM

Single Purchase Counterweight.

FLY SYSTEM DETAILS Operating Position Up stage OP entrance

Batten Drift 3000mmm

Batten Type 48mm OD galvanized round pipe

Batten Pick-ups 4 pickups are located above the grid

Batten Point Load 200kg

Batten W.L.L. 950kg

OVERHEAD OBSTRUCTIONS

1 x water pipe. Starts 2.7m from off the floor and continues to the roof. It has a width of 20cm and protrudes 10cm out from the back wall. The pipe is located 2.3m from the USPS corner edge.

LOADING DOCKLoading dock is not at stage level. Goods must travel flight of stairs to access dock. Goods must travel another flight of stairs from dock to access stage. An elevator is available for heavier goods.

***Elements of your show must be able to fit through these doors***

Loading dock dimension 2000 x 2000 mm

Loading dock height from road surface 1500 mm

Stage access door dimensions 1900mm x 1900mm

Stage door height from dock 3700 mm

RESTRICTIONS/OBSTRUCTIONS

Loading dock is not at stage level. Goods must travel flight of stairs to access dock. Goods must travel another flight of stairs from dock to access stage.

• Multiple staff maybe required to transfer goods up to stage level due to stairs.

• Heavier items subject to dimensions may use the FOH lift located in the foyer.

• Truck access via driveway near corner of Hamersley Rd and Hensman Rd.

ACCESS EQUIPMENTLADDERS

• 1 x 3m A-frame aluminum ladder• 1 x 5.5m extension ladder

ELEVATED WORK PLATFORMS

• Haulotte Star 6 self-propelled• Platform height to 4m

1900mm 900mm

2600mm

2250

mm

1900

mm

1900

mm

Loading dock door dimensions Elevator door dimensions

Page 3: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

2Updated 12 May 2017

DRAPERYA tab track runs from OP entrance to P entrance.

*Type Material Colour Width Height Quantity

Leg Wool Black 3.5m 4.5m 2

Tab Corduroy Black 5.3m 3.8m 1

Border Wool Black 2.45m 2.2m 2

Masking Wool Black 2m 2.25m 1

Masking Wool Black 1.4m 2.6m 1

ORCHESTRAL• 1 x Kawai baby grand piano. Relocation and tuning to be

arranged prior to use.• 1 x upright piano. Relocation and tuning to be arranged

prior to use.• 6 x adjustable music stands.• 2 x piano stools.

ADDITIONAL REQUIREMENTS• No unsupervised access to stage during season allowed.• Only Subiaco Arts Centre staff are authorized to

operate motorized grid system.• Steel capped footwear must be worn during bump-in

and bump-out times.• Closed in foot ware is acceptable during other times.• Emergency exits must remain clear at all times.

ADDITIONAL RIGGING NOTESHANGING SPECIFICATIONS

1. Equipment suspended over the audience1.1 Only chain or wire rope slings will be permitted to

suspend loads over the audience.1.2 All slings shall be in new condition and of sufficient

load rating for the load being suspended.1.3 An “insurance” sling shall be used that has sufficient

capacity to support the load such that the load is supported should failure of main slings occur.

1.4 All shackles used shall be of the rated variety and have the load rating clearly stamped or cast into the shackle, and shall be of suitable load rating for the loads suspended.

2. Equipment suspended over stage/audience2.1 Equipment to be suspended shall have suitable

lifting points fitted. Where special fittings are used these shall be proved by submitting one item (or more if required) for complete testing such that a load certificate can be issued.

2.2 Subiaco Arts Centre reserves the right to refuse to allow any item of equipment or apparatus to be suspended.

3. Slings for suspending items3.1 All slings shall have an identifying mark or number

giving individual identification.3.2 All slings shall have a tag or suitable means of

displaying its S.W.L.3.3 Synthetic or fibre slings may be used to suspend

equipment only with an approved back up sling of wire or chain secured separately into the roof.

3.4 All equipment configurations shall be submitted to Subiaco Arts Centre Management for approval at least one week prior to the date it is intended to be suspended.

3.5 Only slings with S.W.L. certificates may be used at Subiaco Arts Centre.

Page 4: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

3Updated 12 May 2017

LIGHTINGPOSITIONS

Stage LX Bars LX Bars are fixed within grid

Stage LX Grid Height 4400mm

LX #1

Centre point to lighting bar 2410 mm to the middle of bar. Above centre seating bank.

Usable bar width 48 mm round pipes

LX #2

Centre point to lighting bar 4420 mm to the middle of bar. Above centre seating bank.

Usable bar width 48 mm round pipes

LX #3

Centre point to lighting bar 8410mm

Usable bar width 48 mm round pipes

CONTROL

Lighting desk ETC Ion 1000 with fader wing

Control channels 512

Signal output 5 pin DMX

Signal distribution 2 streams of DMX. Not including dimmer line

Remote riggers available onstage Yes – wireless iPad connection

DIMMER RACKS

Lighting circuits 138

Dimmer locations Dimmer racks are located underneath racked seating in the main auditorium crossover corridor. Additional rack is located backstage OP.

2.4kW dimmer racks 8 x Jands HPC12-AZ100R Digital dimmer racks

Total dimmers @2.4kW per dimmer

96

HOUSE LIGHTS

Independent control Yes

Control positions Control Room

Fade time adjustable No

STAGE LUMINARE

Profiles

Make Model Angle Detail/Accessories Watt TotalSelecon Pacific 23 - 50 M size gobo holder, Iris 800 800Selecon Pacific 45 - 75 M size gobo holder, Iris 800 800Selecon Pacific 90 M size gobo holder, Iris 800 800ETC Source four junior 25-50 Iris, Gobo holder 575 575Selecon Acclaim Axial 18 - 34 M size gobo holder, Iris (used in

studio, may not be available for use in the Main)

600 600

Selecon Acclaim Axial 24-44 M size gobo holder, Iris (used in studio, may not be available for use in the Main)

600 600

Fresnels

Make Model Angle Detail/Accessories Watt TotalSelecon Rama 7-55 degree Barndoors 1200 36Selecon Compact 6 7-55 degree Barndoors 1200 10Selecon Axial 650 11

Page 5: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

4Updated 12 May 2017

LED

Make Model Angle Detail/Accessories Watt TotalPhillips RGBAW LED flood wash light Color Blast TRX Holder, Clamp & S/Bond, Power Supply 50w 6Tour pro 1218 LED Par RGBWA 45 Fixed lens 10

Par

Make Model Angle Detail/Accessories Watt TotalBryte Multipar MFL MFL, WFL, NFL lens available 575 6

Flood

Make Model Detail/Accessories Watt TotalStrand Coda 2 2 cells per unit 500w 2Strand Coda Single cell unit 500w 2

Additional lighting

Make Model Angle Detail/Accessories Watt TotalHazer Unique 1Mirror Ball 20inch 20in diameter ball 1

Patching

Location Quantity Numbering (PS to OP) Detail/AccessoriesStage Grid 62 1 - 62 4x 10amp Condition Sound Power AvailableLX1 24 63 - 86 Fixed bar

LX2 28 87 - 114 Fixed bar

LX3 14 115 - 128 Fixed bar

Floor channels 2 132 -131 On back wall

Floor channels 2 129 - 130 At foot of boom

Backstage OP 6 133 - 138 Near loading dock door

POWER

3 Phase Outlets:• 10 On wall next to dimmers under seating bank in

crossover corridor.• 1 On wall. US OP entrance

CABLING

240v extension cableThe theatre has a good stock of extension leads to accommodate the venue’s standard lighting rig. Any additional equipment will require additional cable stock to be sourced.

Looms• 1 x 10m 240v 6-way Weiland loom• 1 x 15m 240v 6-way Weiland loom

3 phase extensions• 1 x 10m 40amp Wilco plug extension

LIGHTING NOTESELECTRICAL EQUIPMENT - TESTING AND TAGGING

All electrical equipment and appliances brought into the venue and requiring to be plugged into a power outlet must be recently tested and tagged to certify the safety of the equipment in accordance with regulations. Equipment or appliances not bearing this tag will not be allowed in the venue and the onus for testing and tagging of equipment rests with the person or company bringing the equipment into the venue.

STANDARD LIGHTING RIG

Subiaco Arts Centre maintains a standard lighting rig consisting of:

• 1 x warm FOH wash • 1 x cool FOH wash • 3 x colour overhead wash• 1 x LED par full stage overhead wash

Page 6: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

5Updated 12 May 2017

• 1x gobo wash• 6 x specials in various locations.

The standard rig design is available upon request. Variations from the standard rig will incur labour charges to apply show specific requirements and return to standard after.

SMOKE

If you wish to use smoke-producing equipment, you must advise the venue of its scheduled usage so the smoke detectors in the area can be isolated.

PYROTECHNICS

Documentation as requested below to be provided to the Subiaco Arts Centre before bump-in:

a. a Dangerous Goods Security Card issued by the Australian Federal Police, which allows the holder to purchase and legally transport up to 5kg of explosives (i.e pyrotechnics).

b. a WA issued Pyrotechnics (Special Use) License for Theatrical Fireworks.

c. compliance with the rules for use of indoor theatrical pyrotechnic use as detailed in the WA Code of Practice Theatrical Fireworks.

AUDIOIn its standard configuration the audio is essentially 3 x mono pairs covering each of the seating banks. Each pair consists of a UPJ covering the lower levels and a UPM covering the upper levels. MM4’s are located around behind the seating in stereo pairs.

CONTROL POSITIONS

Auditorium

Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled.

CONTROL & AMPLIFICATION

Primary Mixer: Midas M32R digital mixer

• 32 channels. 16 as direct XLR inputs (12 xlr to stage) and 16 via Midas DL digital stage box (to stage)

• 16 outputs. 8 as direct XLR outputs and 8 via Midas DL digital stage box.

• 8 DCA and 6 mute groups• 8 digital signal processing effects engines• Wireless iPad remote

SPEAKERS & AMPLIFICATION

FOH speakers

• 3 x Meyer UPJ (main left/right/centre-flown)• 3 x Meyer UPM (delay left/right/centre-flown)• 2 x Meyer USW (underneath seating) - separate send• 6 x Meyer MM4-XP Powered Speaker with Meyer MPS-

488HPE (rear)

Foldback

• 6 x EV T22IM Passive Speaker

Amplifiers

• 1 x Mackie M1400 Power Amplifier• 1 x Yamaha PX5

PLAYBACK

Item Make Model Detail Total

Laptop Apple MacBook

Has full version licensed Qlab 3

1

Double CD player

Denon DN-D4500 In FOH rack 1

MICROPHONES

Make Model Detail/accessories Total

Shure SM58 Dynamic cardioid vocal microphone

1

Shure Beta 58A Dynamic cardioid vocal microphone

2

Sennheiser E935 Dynamic cardioid vocal microphone

3

Shure KSM9 condenser vocal microphone with switchable super cardioid and cardioid

1

Shure SM86 Cardioid condenser vocal 1

Shure SM57 Dynamic cardioid instrument microphone

4

Audix i5 Dynamic cardioid instrument microphone

2

Shure Beta 52A Kick Drum Microphone 1

Sennheiser E901 Half-cardioid, boundary layer condenser for bass drum

1

Sennheiser E904 Dynamic instrument micro-phone for drums

4

Audio Technica ATM 450 Cardioid condenser with side-address

4

Line CM3 Cardioid condenser microphone 2

Page 7: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

6Updated 12 May 2017

Shure KSM32 gc Side-address, cardioid condenser microphone

2

Crown PCC Boundry Mic 3

WIRELESS MICROPHONES

Make Model Detail/accessories Total

Sennheiser SKM2000 Dual radio mic set 2 (4ch’s)

Sennheiser SK2000 Radio mic, Handheld 4

Sennheiser SK2000 Bodypack transmitter, headset

4

DI

Make Model Detail/accessories Total

Radial J48 Active DI 4

Radial JDI Stereo Passive DI 2

Radial Pro D2 2

Countryman Type 10 Direct Box

1

ACCESSORIES

Item Model Total

Straight microphone stand

Round base 6

Boom arm microphone stand

K&M Grey 12

Boom arm microphone stand

Black 8

Short instrument stand Black 4

Short instrument stand K&M Grey 7

Desktop stand 3

LINE PATCHING

Location Quantity Numbering on desk

Detail

From sound desk to back-stage

16 inputs8 outputs

1-16Aux 1 to 4

Digital stage box via AES50 Cable to a Midas DL 16

From Digital stage box to Down stage edge

8 inputs4 outputs

12 way xlr analogue stage box in stage traps

From control room to Back-stage OP

12 sends, 4 returns, 2 used for subs

SPEAKER PATCHING

Location Quantity Numbering on desk

Detail

From control room to grid

4 17 - 20 Used for house system

STANDARD DESK PATCH

Channel Input

1-16 Digital Stage box

17 to 24 Desk inputs 1 to 8

25 to 32 Desk inputs 9 to 16. 4 x radio mics. Control room announce.

Aux in 1-2 TRS- Mac

Aux in 3-4 TRS-Guest

Aux in 5-6 Cd 1

Desk physical out Mix Bus Output

1 Main Left FOH left UPJ

2 Matrix 1 FOH Centre UPJ

3 Main Right FOH Right UPJ

4 Matrix 3 FOH Left fill (delay)

5 Matrix 2 FOH Centre fill (delay)

6 Matrix 4 FOH Right fill (delay)

7 Matrix 5 Auditorium rear

8 Centre Sub

9 -12 (AES 50 cable) 1 to 4 1 to 4 on digital stage box

(Onstage foldback)

13 - 16 FX sends

CABLING

Audio cable

The theatre has a good stock of cable and adaptors to accommodate the venue’s equipment only.

AUDIO NOTES

The main auditorium PA cannot be moved from its existing hanging position without prior consent from the Subiaco Arts Centre Management.

Page 8: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

7Updated 12 May 2017

AUDIO VISUALPROJECTORS

Type Model Detail/accessories Total

BenQ WXGA Projector

MW712 VGA, HDMI, DVI, 1280 x 800 resolution, 3200ANSI

1

SCREENS

Projection screen

1 x PVC Front projection screen Screen dimensions 4m x 3m

Additional screens

2 x PVC Front projection push screen on tripod Screen dimensions 1.8m x 1.2 mm

AV PLAYBACK EQUIPMENT

Item Model Detail/Accessories Total

DVD player Generic Single DVD player. RCA output 2

Laptop Apple MacBook Pro

Has full version licensed Qlab 3 1

Projector Rigging Points

Projector has a mounting assembly and can be rigged from any horizontal lighting bar.

Cabling

The theatre has HDMI, Cat 6 converter, 30m Cat 6 and VGA cables and adaptors to accommodate the venue’s own equipment.

Audio Visual Notes

Lack of depth on the stage area restricts possibilities for rear projection. AV operating position is usually located next sound mixing console.

BACKSTAGECOMMUNICATIONS

Stage Manager’s DeskStage managers position is located next to lighting console in an enclosed control room.

Talkback

Master unit Jands Ezicom 401

Total sub stations 6 x Jands Ezicom beltpacks

Total headsets 8

Wireless talkbackRadioCom BTR-800 with 4 x RadioCom Beltpacks.

Q light systemLeon Audio Q lights system with 1 x master station and 4 x outstations.

Talkback beltpacks and Q light substation located at:• Control Room (master units)• Auditorium sound mixing console• OP backstage entrance (stage door)• PS crossover corridor• OP crossover corridor• CNT crossover corridor

Paging/show relayPaging to the dressing rooms is available from the stage managers desk. Show relay is able to be distributed to all rooms including dressing room, foyer, and rehearsal room.

DRESSING ROOMS

Room Capacity Toilets Shower Details

Backstage 15 2 Yes Showers available above dressing rooms.

Studio overflow

15 1 Yes Located underneath seating OP side. Subject to availability

LAUNDRY/WARDROBE

Washing machines 1 x 5kg Kleenmaid

Dryers 1 x 5kg Hoover

Drying rooms No

Iron/ironing board 2 x Kenwood 2200w

Clothes racks 2 @ 2000 x 1500 mm

PRODUCTION FACILITIES

Production desk

Production desk set-up in the center of the stalls. Table accommodates 2 people with dimmable lighting, DMX for the lighting desk via Laptop, talkback.

Production office No

Phone Yes, access to phone in management office.

Fax Yes, access to phone in management office.

Internet access Yes, Wi-Fi only

Page 9: TECHNICAL SPECIFICATIONS - Perth Theatre Trust...Auditorium Located at rear of the stalls. Towards OP side. Dedicated position, no seats pulled. CONTROL & AMPLIFICATION Primary Mixer:

TECHNICAL SPECIFICATIONSMAIN AUDITORIUM

8Updated 12 May 2017

GREEN ROOM/DRESSING ROOM

Tea/coffee facilities Yes, 2L kettle

Fridge/freezer Yes, Kenwood 250L

Microwave Yes, Sanyo 1200W

Running water Yes

ADDITIONAL INFORMATION

ADDITIONAL HIRE EQUIPMENTAdditional hire equipment is available at extra cost.

REHEARSAL SPACES

• Rehearsal Room 12m x 9m, Semi sprung floor. Bookings required for use

• Undercroft Room 8.5m x 14m, Carpet floor. Bookings required for use.

STAFF• Please take particular care when advising equipment

delivery including sets, props and costumes as staff will be available only at the times requested. Staff will be charged for unless at least 48 hours’ notice of change is given to Subiaco Arts Centre.

• Casual staff operate under the DCA Venue Management Collective Agreement.

• One Technical Staff member from Subiaco Arts Centre must be present at all times for shows in the main auditorium.

STAGE REPORTS

A copy of the Company Stage Managers Report for each performance must be provided to the Subiaco Arts Centre Technical Manager on the morning after each performance.

This is a requirement for ongoing Quality Assurance Certification and the Occupational Health and Safety of the venue.

VENUE PLANS - AVAILABLE ON REQUEST

• Venue plan (DWG or PDF) • Venue section (DWG or PDF)

MORE INFORMATION

If you have any questions regarding technical specifications, please contact Subiaco Arts Centre’s Technical Manager:

Troy Williams T: +61 8 9380 3003 F: +61 8 9380 3030 E: [email protected]

This document contains general information only and is current at the time of going to print. All critical measurements should be checked on site. Availability of equipment and space is subject to performance schedules. Please check with the technical manager when booking the space for your performance.