    SECTION I: INTRODUCTION 9 TRAINING OBJECTIVES ------------------------------------------------------------------------------------------------------------------------- 10 

    ABOUT PLATINUM ------------------------------------------------------------------------------------------------------------------------------ 11 PLATINUM CONTROL: IMS & BMS ---------------------------------------------------------------------------------------------------------- 11 HOW IT WORKS ---------------------------------------------------------------------------------------------------------------------------------- 12 THE BRAINS --------------------------------------------------------------------------------------------------------------------------------------- 13 APPLICATIONS ------------------------------------------------------------------------------------------------------------------------------------ 14 INSTALLATIONS ---------------------------------------------------------------------------------------------------------------------------------- 15 ADDITIONAL CONSIDERATIONS ------------------------------------------------------------------------------------------------------------- 15 THE OLD WAY------------------------------------------------------------------------------------------------------------------------------------- 16 POTENTIAL CONSEQUENCES ----------------------------------------------------------------------------------------------------------------- 16 THE BETTER WAY: BMS & IMS --------------------------------------------------------------------------------------------------------------- 17 PAIN POINT CONSIDERATIONS--------------------------------------------------------------------------------------------------------------- 17 PLATINUM CONTROL’S PRODUCTS --------------------------------------------------------------------------------------------------------- 18 

    ROI – EXPECTED COSTS ------------------------------------------------------------------------------------------------------------------------ 19 ROI – POTENTIAL UNANTICIPATED COSTS ------------------------------------------------------------------------------------------------ 20 WHO BENEFITS FROM BURNER MANAGEMENT ---------------------------------------------------------------------------------------- 21 COMPETITORS ------------------------------------------------------------------------------------------------------------------------------------ 21 SUPERIOR MANUFACTURING ---------------------------------------------------------------------------------------------------------------- 22 PLATINUM CONTROL BENEFITS ------------------------------------------------------------------------------------------------------------- 23 THE PLATINUM WAY---------------------------------------------------------------------------------------------------------------------------- 24 

    SECTION II: COMBUSTION FUNDAMENTALS 25 FIRE TRIANGLE ----------------------------------------------------------------------------------------------------------------------------------- 26 

    CONTROLLED COMBUSTION ----------------------------------------------------------------------------------------------------------------- 28 CONTROL BY DESIGN ----------------------------------------------------------------------------------------------------------------------- 29 CONTROL BY INSTRUMENTS -------------------------------------------------------------------------------------------------------------- 30 

    TYPES OF BURNER ASSEMBLIES ------------------------------------------------------------------------------------------------------------- 31 DIRECT FIRED UNITS ------------------------------------------------------------------------------------------------------------------------ 32 INDIRECT FIRED UNITS --------------------------------------------------------------------------------------------------------------------- 33 

    BURNER CATEGORIES -------------------------------------------------------------------------------------------------------------------------- 34 LIQUID FUELED BURNERS ------------------------------------------------------------------------------------------------------------------ 34 GAS FUELED BURNERS---------------------------------------------------------------------------------------------------------------------- 34 FORCED DRAFT BURNERS ----------------------------------------------------------------------------------------------------------------- 34 NATURAL DRAFT BURNERS---------------------------------------------------------------------------------------------------------------- 35 

    TYPES OF OILFIELD EQUIPMENT WITH BURNER ASSEMBLIES ----------------------------------------------------------------------- 38  HEATER TREATER ---------------------------------------------------------------------------------------------------------------------------- 38 ELECTROSTATIC TREATER ------------------------------------------------------------------------------------------------------------------ 38 HEATED SEPARATOR ------------------------------------------------------------------------------------------------------------------------ 38 GLYCOL DEHYDRATOR ---------------------------------------------------------------------------------------------------------------------- 39 AMINE UNIT ----------------------------------------------------------------------------------------------------------------------------------- 39 LINE HEATER ---------------------------------------------------------------------------------------------------------------------------------- 40 GAS PRODUCTION UNIT ------------------------------------------------------------------------------------------------------------------- 40 COMBUSTOR ---------------------------------------------------------------------------------------------------------------------------------- 41 COMBINATION UNIT ------------------------------------------------------------------------------------------------------------------------ 41 

  • 8/20/2019 Technical Training Manual

    4/225

     

    4TECHNICAL TRAINING 

    MULTI-WELL UNIT --------------------------------------------------------------------------------------------------------------------------- 42 TANK HEATER --------------------------------------------------------------------------------------------------------------------------------- 42 FLARE -------------------------------------------------------------------------------------------------------------------------------------------- 42 

    THE FIRETUBE ------------------------------------------------------------------------------------------------------------------------------------ 43 HEAT FLOW IN THE FIRETUBE ------------------------------------------------------------------------------------------------------------ 45 FIRETUBE RETURN BEND DESIGNS ------------------------------------------------------------------------------------------------------ 47 

    THE FIRETUBE STACK ----------------------------------------------------------------------------------------------------------------------- 47 FLASH ARRESTOR/STACK HEAD ---------------------------------------------------------------------------------------------------------- 48 TURBULATORS -------------------------------------------------------------------------------------------------------------------------------- 49 

    THE COMBUSTION CHAMBER ---------------------------------------------------------------------------------------------------------------- 50 THE FLAME ARRESTOR --------------------------------------------------------------------------------------------------------------------- 52 BENEFITS OF FLAME ARRESTORS -------------------------------------------------------------------------------------------------------- 54 TYPES OF FLAME ARRESTORS ------------------------------------------------------------------------------------------------------------ 55 FLAME ARRESTOR OPERATIONS --------------------------------------------------------------------------------------------------------- 56 STANDARD FLAMECO NOMENCLATURE ----------------------------------------------------------------------------------------------- 57 

    MAIN & PILOT BURNER ASSEMBLIES ------------------------------------------------------------------------------------------------------- 58 THE BURNER NOZZLE ----------------------------------------------------------------------------------------------------------------------- 60 THE MIXER ------------------------------------------------------------------------------------------------------------------------------------- 61 THE PILOT -------------------------------------------------------------------------------------------------------------------------------------- 62 

    THE FUEL GAS TRAIN --------------------------------------------------------------------------------------------------------------------------- 64 FUEL GAS TRAIN DRAWING --------------------------------------------------------------------------------------------------------------- 68 FUEL GAS TRAIN DRAWING WITH BMS ------------------------------------------------------------------------------------------------ 68 CANADIAN B149. 3 FUEL GAS TRAIN DRAWING ------------------------------------------------------------------------------------- 69 STANDARD FUEL GAS TRAIN P&ID WITH BMS --------------------------------------------------------------------------------------- 69 

    VESSEL/BURNER EQUIPMENT INSPECTION ---------------------------------------------------------------------------------------------- 70 OPERATIONAL INSPECTIONS -------------------------------------------------------------------------------------------------------------- 70 INTERNAL COMPONENTS INSPECTIONS ----------------------------------------------------------------------------------------------- 70 CORROSION ----------------------------------------------------------------------------------------------------------------------------------- 71 LEAKS -------------------------------------------------------------------------------------------------------------------------------------------- 71 OBSTRUCTIONS ------------------------------------------------------------------------------------------------------------------------------- 72 FLAME ARRESTOR CELL -------------------------------------------------------------------------------------------------------------------- 72 

    GASKETS ---------------------------------------------------------------------------------------------------------------------------------------- 73 FUEL GAS TRAIN ------------------------------------------------------------------------------------------------------------------------------ 73 BURNER SYSTEMS --------------------------------------------------------------------------------------------------------------------------- 74 THE STACK ------------------------------------------------------------------------------------------------------------------------------------- 75 GAUGES AND TEMPERATURE CONTROLS --------------------------------------------------------------------------------------------- 75 

    INITIAL BURNER STARTUP --------------------------------------------------------------------------------------------------------------------- 76 SHUTDOWN PROCEDURE --------------------------------------------------------------------------------------------------------------------- 78 RECOMMENDED MAINTENANCE ----------------------------------------------------------------------------------------------------------- 79 

    SECTION III: PLATINUM CONTROL’S BMS 81 PRE-INSTALLATION QUESTIONS ------------------------------------------------------------------------------------------------------------- 83 WARRANTY STATEMENT ---------------------------------------------------------------------------------------------------------------------- 84 INTRODUCTION ---------------------------------------------------------------------------------------------------------------------------------- 85 COMPONENTS AND SPECIFICATIONS ------------------------------------------------------------------------------------------------------ 86 

    SHIPPING BOX CONTENTS ----------------------------------------------------------------------------------------------------------------- 86 MICROPROCESSOR BOARD ------------------------------------------------------------------------------------------------------------ 87 PLATINUM BMS-731™ PROCESSOR BOARD --------------------------------------------------------------------------------------- 87 VALVES/TERMINATION BOARD ------------------------------------------------------------------------------------------------------ 88 

    PLATINUM BMS-731 IGNITION MODULE ---------------------------------------------------------------------------------------------- 88 

  • 8/20/2019 Technical Training Manual

    5/225

     

    5TECHNICAL TRAINING 

    PILOT ASSEMBLY ----------------------------------------------------------------------------------------------------------------------------- 89 INSTALLATION ------------------------------------------------------------------------------------------------------------------------------------ 90 

    PRE-INSTALLATION REQUIREMENTS --------------------------------------------------------------------------------------------------- 90 MOUNTING THE MAIN CONTROL BOX ------------------------------------------------------------------------------------------------- 91 INSTALLING SOLENOID VALVES ---------------------------------------------------------------------------------------------------------- 92 MOUNTING THE PILOT ASSEMBLY ------------------------------------------------------------------------------------------------------ 98 

    SETTING-UP THE IGNITION MODULE ------------------------------------------------------------------------------------------------- 102 MOUNTING THE IGNITION MODULE ------------------------------------------------------------------------------------------------- 102 INSTALLING THE TEMPERATURE DEVICE -------------------------------------------------------------------------------------------- 108 

    INSTALLING THE RTD ------------------------------------------------------------------------------------------------------------------ 108 INSTALLING THE TYPE K THERMOCOUPLE -------------------------------------------------------------------------------------- 111 

    CONNECTING EXTERNAL DEVICES ----------------------------------------------------------------------------------------------------- 114 CONNECTING EXTERNAL ESD (STATUS OUT) --------------------------------------------------------------------------------------- 116 GROUNDING WIRES ----------------------------------------------------------------------------------------------------------------------- 116 CONNECTING VALVES/TERMINATION BOARD TO MAIN CONTROL BOX --------------------------------------------------- 118 CONNECTING POWER TO THE MAIN CONTROL BOX ----------------------------------------------------------------------------- 118 

    OPERATING-------------------------------------------------------------------------------------------------------------------------------------- 121 POWERING UP ------------------------------------------------------------------------------------------------------------------------------ 121 FACTORY SETUP ---------------------------------------------------------------------------------------------------------------------------- 122 

    SOFTWARE REVISION NUMBER ---------------------------------------------------------------------------------------------------- 123 TEMPERATURE CONTROL ------------------------------------------------------------------------------------------------------------ 123 LOW PRESSURE SWITCH-------------------------------------------------------------------------------------------------------------- 123 HI PRESSURE SWITCH ----------------------------------------------------------------------------------------------------------------- 124 ESD SOLENOID -------------------------------------------------------------------------------------------------------------------------- 124 ESD VALVE SWITCH (POC) ----------------------------------------------------------------------------------------------------------- 124 MAIN VALVE SWITCH (POC) --------------------------------------------------------------------------------------------------------- 125 TEMP SENSOR TYPE ------------------------------------------------------------------------------------------------------------------- 125 SPARE SWITCH -------------------------------------------------------------------------------------------------------------------------- 126 SET REMOTE ON/OFF ----------------------------------------------------------------------------------------------------------------- 126 PILOT OPERATION---------------------------------------------------------------------------------------------------------------------- 127 ENABLE THE HIGH FIRE VALVE ------------------------------------------------------------------------------------------------------ 127  

    SET THE MODBUS BAUD RATE ------------------------------------------------------------------------------------------------------ 127 SET MODBUS PARITY ------------------------------------------------------------------------------------------------------------------ 128 SET NUMBER OF MODBUS STOP BITS -------------------------------------------------------------------------------------------- 128 SET MODBUS ADDRESS --------------------------------------------------------------------------------------------------------------- 128 BACKLIGHT ALWAYS ON -------------------------------------------------------------------------------------------------------------- 129 

    OPERATING PARAMETERS --------------------------------------------------------------------------------------------------------------- 130 TEMPERATURE SCALE ----------------------------------------------------------------------------------------------------------------- 131 ALARM SETPOINT (HIGH TEMPERATURE SHUTDOWN) ---------------------------------------------------------------------- 132 TEMPERATURE CONTROL SETTING ------------------------------------------------------------------------------------------------ 133 IGNITION DELAY TIME ---------------------------------------------------------------------------------------------------------------- 134 SETTING THE MAIN VALVE DELAY ------------------------------------------------------------------------------------------------- 134 SETTING THE FLAME SENSE DELAY ------------------------------------------------------------------------------------------------ 135 HIGH FIRE DELAY ----------------------------------------------------------------------------------------------------------------------- 135 SETTING THE HIGH FIRE TEMPERATURE SETPOINT --------------------------------------------------------------------------- 136 SPARE SWITCH DELAY ----------------------------------------------------------------------------------------------------------------- 136 TIME LOG --------------------------------------------------------------------------------------------------------------------------------- 137 EXITING THE OPERATING PARAMETERS ----------------------------------------------------------------------------------------- 138 

    IGNITION PROCEDURE -------------------------------------------------------------------------------------------------------------------- 139 CONFIRM PROPER FUNCTIONALITY OF THE FLAME SENSING PROBE ------------------------------------------------------- 140 

    TROUBLESHOOTING -------------------------------------------------------------------------------------------------------------------------- 141 DISPLAY ERROR CODES ------------------------------------------------------------------------------------------------------------------- 141 MICROPROCESSOR CODES -------------------------------------------------------------------------------------------------------------- 144 

  • 8/20/2019 Technical Training Manual

    6/225

     

    6TECHNICAL TRAINING 

    TIPS FOR TROUBLESHOOTING ---------------------------------------------------------------------------------------------------------- 146 PLATINUM RECOMMENDED SPARE PARTS LIST --------------------------------------------------------------------------------------- 149 BMS-731 CURRENT DRAW ------------------------------------------------------------------------------------------------------------------ 150 ADDENDUM DRAWINGS--------------------------------------------------------------------------------------------------------------------- 151 

    BMS 731/BTEX INTERCONNECT DIAGRAM ----------------------------------------------------------------------------------------- 151 BASIC P&ID ---------------------------------------------------------------------------------------------------------------------------------- 152 

    FULL P&ID ------------------------------------------------------------------------------------------------------------------------------------ 153 

    Optional BMS 731-BTEX Addendum 154 COMPONENTS AND SPECIFICATIONS ---------------------------------------------------------------------------------------------------- 155 

    BTEX ADAPTER BOARD (PIGGYBACK BOARD) -------------------------------------------------------------------------------------- 155 INSTALLATION ---------------------------------------------------------------------------------------------------------------------------------- 156 

    INSTALLING THREE (3) TYPE K THERMOCOUPLE ---------------------------------------------------------------------------------- 156 OPERATING-------------------------------------------------------------------------------------------------------------------------------------- 158 

    POWERING UP ------------------------------------------------------------------------------------------------------------------------------ 158 OPERATING PARAMETERS --------------------------------------------------------------------------------------------------------------- 159 

    ALARM SETPOINT (HIGH TEMPERATURE SHUTDOWN) ---------------------------------------------------------------------- 159 

    SECTION IV: PLATINUM CONTROL’S IMS 161 PRE-INSTALLATION QUESTIONS ----------------------------------------------------------------------------------------------------------- 162 WARRANTY STATEMENT -------------------------------------------------------------------------------------------------------------------- 163 INTRODUCTION -------------------------------------------------------------------------------------------------------------------------------- 164 

    POWER---------------------------------------------------------------------------------------------------------------------------------------- 164 OPERATION ---------------------------------------------------------------------------------------------------------------------------------- 164 IGNITER MODE ----------------------------------------------------------------------------------------------------------------------------- 164 FLARE MODE -------------------------------------------------------------------------------------------------------------------------------- 164 

    APPLICATIONS ------------------------------------------------------------------------------------------------------------------------------ 165 COMPONENTS AND SPECIFICATIONS ---------------------------------------------------------------------------------------------------- 166 

    SHIPPING BOX CONTENTS --------------------------------------------------------------------------------------------------------------- 166 MICROCONTROLLER BOARDS ---------------------------------------------------------------------------------------------------------- 167 

    PLATINUM-500 DISPLAY BOARD --------------------------------------------------------------------------------------------------- 167 PLATINUM-500 MAIN BOARD ------------------------------------------------------------------------------------------------------ 168 IGNITION MODULE -------------------------------------------------------------------------------------------------------------------- 169 PILOT ASSEMBLY ----------------------------------------------------------------------------------------------------------------------- 169 

    INSTALLATION ---------------------------------------------------------------------------------------------------------------------------------- 170 PRE-INSTALLATION REQUIREMENTS ------------------------------------------------------------------------------------------------- 170 EXAMPLE OF A FUEL GAS TRAIN ------------------------------------------------------------------------------------------------------- 171 MOUNTING THE MAIN CONTROL BOX ----------------------------------------------------------------------------------------------- 172 INSTALLING SOLENOID VALVES -------------------------------------------------------------------------------------------------------- 172 MOUNTING THE PILOT ASSEMBLY ---------------------------------------------------------------------------------------------------- 177 INSTALLING THE IGNITION MODULE ------------------------------------------------------------------------------------------------- 179 CONNECTING EXTERNAL DEVICES ----------------------------------------------------------------------------------------------------- 182 CONNECTING EXTERNAL ESD (STATUS OUT) --------------------------------------------------------------------------------------- 182 GROUNDING WIRES ----------------------------------------------------------------------------------------------------------------------- 182 CONNECTING MAIN BOARD TO MAIN CONTROL BOX --------------------------------------------------------------------------- 183 CONNECTING POWER TO THE MAIN CONTROL BOX ----------------------------------------------------------------------------- 183 

    LINE POWER ----------------------------------------------------------------------------------------------------------------------------- 183 

  • 8/20/2019 Technical Training Manual

    7/225

     

    7TECHNICAL TRAINING 

    SOLAR POWER WITH BATTERY BACKUP ----------------------------------------------------------------------------------------- 184  LINE POWER WITH BATTERY BACKUP -------------------------------------------------------------------------------------------- 186 

    SETUP --------------------------------------------------------------------------------------------------------------------------------------------- 188 POWERING UP ------------------------------------------------------------------------------------------------------------------------------ 188 INITIAL SETUP ------------------------------------------------------------------------------------------------------------------------------- 188 

    POWER SELECTION -------------------------------------------------------------------------------------------------------------------- 189 

    OPERATING MODE --------------------------------------------------------------------------------------------------------------------- 189 SOLENOID VOLTAGE* ----------------------------------------------------------------------------------------------------------------- 189 ESD SOLENOID* ------------------------------------------------------------------------------------------------------------------------- 189 PILOT SOLENOID* ---------------------------------------------------------------------------------------------------------------------- 190 MAIN SOLENOID* ---------------------------------------------------------------------------------------------------------------------- 190 

    IDLE STATE ----------------------------------------------------------------------------------------------------------------------------------- 191 OPERATING PARAMETERS SETUP ----------------------------------------------------------------------------------------------------- 192 

    FIRMWARE REVISION NUMBER ---------------------------------------------------------------------------------------------------- 192 VENT DELAY TIME* -------------------------------------------------------------------------------------------------------------------- 192 SPARK DELAY TIME* ------------------------------------------------------------------------------------------------------------------- 192 MAIN VALVE DELAY TIME* ---------------------------------------------------------------------------------------------------------- 192 FLAME SENSE DELAY TIME ----------------------------------------------------------------------------------------------------------- 193 REMOTE ON/OFF ----------------------------------------------------------------------------------------------------------------------- 193 AUTO ON --------------------------------------------------------------------------------------------------------------------------------- 193 STATUS LED MODE -------------------------------------------------------------------------------------------------------------------- 194 DISPLAY MODE -------------------------------------------------------------------------------------------------------------------------- 194 POWER MODE -------------------------------------------------------------------------------------------------------------------------- 195 OPERATING MODE --------------------------------------------------------------------------------------------------------------------- 195 SOLENOID VOLTAGE* ----------------------------------------------------------------------------------------------------------------- 196 ESD SOLENOID TYPE* ----------------------------------------------------------------------------------------------------------------- 196 PILOT SOLENOID TYPE* --------------------------------------------------------------------------------------------------------------- 197 MAIN SOLENOID TYPE* --------------------------------------------------------------------------------------------------------------- 197 FACTORY RESET ------------------------------------------------------------------------------------------------------------------------- 198 PASSWORD ------------------------------------------------------------------------------------------------------------------------------ 198 TIME AND DATE ------------------------------------------------------------------------------------------------------------------------ 199 

    CLEAR LOG ------------------------------------------------------------------------------------------------------------------------------- 199 VIEW LOG -------------------------------------------------------------------------------------------------------------------------------- 200 

    EXIT SETUP ----------------------------------------------------------------------------------------------------------------------------------- 200 OPERATING-------------------------------------------------------------------------------------------------------------------------------------- 201 

    FRONT PANEL ------------------------------------------------------------------------------------------------------------------------------- 201 POWERING UP ------------------------------------------------------------------------------------------------------------------------------ 202 SMART START ------------------------------------------------------------------------------------------------------------------------------- 202 RUNNING ------------------------------------------------------------------------------------------------------------------------------------ 203 IGNITER & FLARE MODE ----------------------------------------------------------------------------------------------------------------- 203 RUNNING WITH REMOTE ON/OFF ---------------------------------------------------------------------------------------------------- 204 RUNNING WITH LOW BATTERY CONDITION --------------------------------------------------------------------------------------- 204 CONFIRM PROPER FUNCTIONALITY OF THE FLAME SENSING PROBE ------------------------------------------------------- 205 

    RATINGS------------------------------------------------------------------------------------------------------------------------------------------ 206 POWER SUPPLY ----------------------------------------------------------------------------------------------------------------------------- 206 POWER CONSUMPTION (RUNNING) ------------------------------------------------------------------------------------------------- 206 FUSE ------------------------------------------------------------------------------------------------------------------------------------------- 206 CLOCK BACKUP BATTERY ---------------------------------------------------------------------------------------------------------------- 206 ESD OUTPUT RELAY ----------------------------------------------------------------------------------------------------------------------- 206 

    TROUBLESHOOTING -------------------------------------------------------------------------------------------------------------------------- 207 ESD SCREEN MESSAGES ------------------------------------------------------------------------------------------------------------------ 207 ERROR SCREEN MESSAGES -------------------------------------------------------------------------------------------------------------- 211 MISCELLANEOUS MESSAGES ----------------------------------------------------------------------------------------------------------- 212 

  • 8/20/2019 Technical Training Manual

    8/225

     

    8TECHNICAL TRAINING 

    TIPS FOR TROUBLESHOOTING ---------------------------------------------------------------------------------------------------------- 213 ONLINE TRAINING RESOURCES -------------------------------------------------------------------------------------------------------- 214 AVAILABLE TECHNICAL RESOURCES -------------------------------------------------------------------------------------------------- 215 CONCLUSION -------------------------------------------------------------------------------------------------------------------------------- 215 

    ADDENDUM DRAWINGS--------------------------------------------------------------------------------------------------------------------- 216 PLATINUM-500 ELECTRIC ---------------------------------------------------------------------------------------------------------------- 216 

    PLATINUM-500 PNEUMATIC ------------------------------------------------------------------------------------------------------------ 217 

    Glossary 219 

  • 8/20/2019 Technical Training Manual

    9/225

     

    9TECHNICAL TRAINING 

    SECTION I: INTRODUCTION

  • 8/20/2019 Technical Training Manual

    10/225

     

    10TECHNICAL TRAINING 

    TRAINING OBJECTIVES

    1.  Gain awareness of fired vessel applications.

    2.  Work to have an understanding of the components related to natural draft production

    equipment.

    3.  Establish competence in the installation and operations of Platinum Control’s Burner

    Management Systems.

    NOTE

    At all times we will consider Safety, Efficiency, and Regulatory requirements. Please consult and follow

    appropriate OSHA, NFPA, Canadian Standard, Industry and Company specific safety practices. Always

    wear appropriate PPE including, but not limited to the following items:

    •  Hard hat

    •  Safety glasses

    •  FR clothing

    •  Steel-toe boots

    •  Hearing protection

  • 8/20/2019 Technical Training Manual

    11/225

     

    11TECHNICAL TRAINING 

    ABOUT PLATINUM

    Our team has decades of experience in the oil & gas field and a thorough understanding of all the

    production equipment involved. That knowledge has driven our development of the most

    technologically advanced, reliable and user-friendly BMS on the market.

    Beyond a great product, we value and continue to build strong partnerships with our clients. Always

    committed to 100% satisfaction, we provide 24/7 technical support for the life of the unit.

    PLATINUM CONTROL: IMS & BMS

    Ignition Management System

    Platinum Control’s Ignition Management System is specifically designed to light, monitor, and re-ignite

    natural draft burners used in heating systems for oil and gas production equipment and gas flares.

    Burner Management System

    Platinum Control’s Burner Management System provides remote burner access, automated ignition and

    temperature control for oil and gas production. The system records essential data and safely automates

    heating processes, decreasing injury risk, maximizing well production and facilitating environmental

    compliance.

    The above image is of a Burner Management System

    (BMS), the BMS-731. The above image is of an Ignition Management

    System (IMS), the Platinum-500.

  • 8/20/2019 Technical Training Manual

    12/225

     

    12TECHNICAL TRAINING 

    HOW IT WORKS

    BMS & IMS (IGNITER Mode)

      Both the BMS and IMS monitor for the presence of a pilot flame through an igniter rod whichfeeds the signal back to a microcontroller to determine a safe sequence of events based on the

    signal.

    •  Both the BMS and IMS control the pilot, main solenoids and ESD solenoids. In the absence of a

    lit pilot, the system will shut all gas sources feeding the pilot and main burner and wait for a

    user set wait time before attempting a re-ignition sequence.

    •  Both systems, in the event of a positive ignition will sense the flame and proceed with

    monitoring. If either system senses a flame ignition failure, they will lock out the ignition process

    after three failed attempts and wait for an operator to troubleshoot and reset the system.

    IMS (FLARE Mode)

    •  In flare mode, the IMS does not control solenoids. In the absence of a flame, the IMS will wait

    for a fixed delay time of 5 seconds before attempting a re-ignition sequence.

    •  In the event of a positive ignition, the system will sense the flame and proceed with monitoring.

    In the event of flame ignition failure, the IMS will restart automatically without any limitations.

    BMS

    •  In addition to the features shared with IMS, the BMS has temperature control to establish and

    maintain operator adjustable temperature set points.

    •  Remote capability allowing personnel to monitor and adjust operations from off site.

    •  The ability to communicate an alarm in shutdown conditions to notify operators of upsetconditions.

    Image of Platinum’s ignition module, wiring, and pilot installed in a f lame arrestor.

  • 8/20/2019 Technical Training Manual

    13/225

     

    13TECHNICAL TRAINING 

    THE BRAINS

    Manufactured under the strictest production parameters, the control panel is the brain of our BMS/IMS.

    Each is precision engineered and rigorously tested to withstand the harshest weather conditions, while

    ensuring reliable uptime. We simply do not take shortcuts in the quality we put into every controller.

    The system is designed to easily integrate with your other monitoring and data systems to allow

    complete visibility into your production site.

    A simple interface with intuitive alerts, the system is designed to be very user-friendly in the field and

    provide the control to remotely manage your production site.

    Platinum’s BMS-731 microprocessor and valves/termination

    board.

    Platinum’s IMS Platinum-500 display and main board.

  • 8/20/2019 Technical Training Manual

    14/225

     

    14TECHNICAL TRAINING 

    APPLICATIONS

    Platinum Control’s Burner Management Systems support any natural draft burner up to 10MMBtu/Hr

    on oil & gas production equipment. Whether you need one unit or want to integrate all of your burner

    systems, Platinum Control can give you the insight to manage your:

    • Production Units

    • Treaters

    • Dehydrators

    • VOC Combustors

    • Heated Separators

    • Oil Stabilizers

    • Line Heaters

    • Amine Plants

    • Combination Units

    • Multiwell Units

    • Tank Heaters

    • Flares

    Platinum BMS-731 installed on a gas production unit.

  • 8/20/2019 Technical Training Manual

    15/225

     

    15TECHNICAL TRAINING 

    INSTALLATIONS

    In yard installations are easier, but will require adjustments in the field after final installation. On

    location installations are more involved, but maximize the opportunity for optimum operations. 

    • In yard: Primarily during the manufacturing or refurbishment process

    • On location: During refurbishment or as an upgrade

    The above image is of a new treater with a Platinum BMS-731installed in the equipment manufacturer yard. 

     Above is an example of a retrofit installation of a PlatinumBMS-731 on a glycol dehydrator in the field.

    In retrofit applications always examine flame arrestor to insure free of plugging, check burner fuel train

    for proper operations in addition to inspecting firetube for obstructions, sooting, or hot spots.

    All of these items can lead to issues with burner capability and flame quality.

    The end result can be improper operation, damage to production equipment, lost revenue or injury.

    Carbon debris inside of firetube. Collapsed “hotspot” inside of a firetube. Sooting accumulation inside of a firetube.

    ADDITIONAL CONSIDERATIONS

    •  Burner manifold components

    •  Inspection of burner systems for installation

    •  Continuing PM of burner systems

    •  Parts and service

  • 8/20/2019 Technical Training Manual

    16/225

     

    16TECHNICAL TRAINING 

    THE OLD WAY

    Much of the field is using antiquated methods, such as using a rag on a stick to light burners.

    Information compiled from OSHA, Federal Bureau of Labor, NIOSH, API, and CDC tells us.

    •  From 2006-2010, the Oil and Gas Industry experienced:

    o  15% of incidents fire and explosion related

    o  Injury claims > $47m

    o  Over 81,350 lost work hours

    Rag on a stick used to light a

    burner. 

    POTENTIAL CONSEQUENCES

    Failure to use Burner Management Systems could result in damaged equipment, lost revenue, legal

    claims, injury or fatality.

    Image of a burned glycol dehydration unit.  Treaters and battery on fire in West Texas.

  • 8/20/2019 Technical Training Manual

    17/225

     

    17TECHNICAL TRAINING 

    THE BETTER WAY: BMS & IMS

    INCREASE SAFETYGAIN PRODUCTION

    EFFICIENCIES

    MINIMIZE ENVIRONMENTAL

    IMPACT

    •  Prevents serious injury or

    death from manually

    lighting and re-lighting

    burners

    •  BMS provides

    temperature control that

    protects and preserves

    equipment

    •  Limits loss of revenue

    due to claims or suits

    •  Reduces production shut-

    downs due to burner

    failure

    •  Remote control of the

    BMS decreases need for

    field engineers to go on

    site to monitor systems

    •  Increases visibility into

    your system’s

    performance

    •  BMS temperature

    controlled burning

    prevents explosions

    •  Positions your company for

    current and future

    compliance requirements

    •  BMS delivers accurate

    temperature and pressure

    control to ensure complete

    incineration of unusable or

    harmful gases

    •  Prevents harmful gasesfrom releasing into the

    environment

    PAIN POINT CONSIDERATIONS

     A “Yes” response to any of the below questions warrants the use of a BMS or IMS.

    1.  Are personnel using an open flame (torch, rag on a stick) to light burners?

    2.  Have you ever had a burner related near miss, recordable, or lost time incident?

    3.  Have you ever had a burner failure cause continuous gas venting to the atmosphere?

    4.  Has a burner failure ever prevented you from selling oil or natural gas?

    5.  Have you ever had a burner failure cause call-outs for the lease operator or service personnel to

    relight the burner?

    6.  Have you ever risked or had production equipment damage due to a burner failure?

    7.  Have you ever been fined because of fugitive emissions?

  • 8/20/2019 Technical Training Manual

    18/225

     

    18TECHNICAL TRAINING 

    PLATINUM CONTROL’S PRODUCTS

    MODEL Platinum – 500 BMS – 731 BMS – BTEX

    Applications Gas FlaresProduction

    EquipmentProduction Equipment Production Equipment

    Operation Mode Flare Igniter --- ---

    Ignition Control Yes Yes Yes Yes

    Valve Control --- Yes Yes Yes

    Temperature

    Control--- ---

    RTD

    K-Type Thermocouple

    K-Type Thermocouple

    (Can be used to measure

    temperature at three

    different points)

    Typical Power

    Connections

    (Not including

    valves)

    12/24 V

    0.08 W

    12/24 V

    0.19 W

    12/24 V

    9.6 W

    12/24 V

    9.6 W

    Internal Battery

    Option

    12 V sealed lead-acid

    Up to 14 AH--- ---

    Internal Solar

    Charge Controller

    Vmp: 17.3 V

    Power: Up to 30 W usable--- ---

    Solar Enabled Yes Yes Yes

    Redundant

    ShutdownYes Yes Yes

    Event Record Log Yes --- ---

    Auto-Restart After

    Power FailureYes --- ---

    Input(s) for Safety

    DevicesYes Yes Yes

    Communications --- Yes Yes

    Certification Pending

    CSA/UL Certified for its

    intended use

    (Model SF 731)

    NFPA 87 Standards 

    CSA/UL Certified for its

    intended use

    (Model SF 731)

    NFPA 87 Standards 

    Classification Class I, Division II Class I, Division II Class I, Division II

  • 8/20/2019 Technical Training Manual

    19/225

     

    19TECHNICAL TRAINING 

    ROI – EXPECTED COSTS

  • 8/20/2019 Technical Training Manual

    20/225

     

    20TECHNICAL TRAINING 

    ROI – POTENTIAL UNANTICIPATED COSTS

  • 8/20/2019 Technical Training Manual

    21/225

     

    21TECHNICAL TRAINING 

    WHO BENEFITS FROM BURNER MANAGEMENT

    •  Distributors

    o  Providing customer needed product and service

    •  OEMs

    o  Leadership and credibility with customers

    •  End Users

    o  Field Personnel

    o  Corporate Engineering

    o  Corporate Management

    o  Safety Officer

    COMPETITORS

    •  Canalta

    •  ACL Manufacturing

    •  Profire

    •  SureFire

    •  Patton

    Platinum Control offers a more consistent, technologically advanced product with the following

    benefits:

    •  CSA/UL Certified for its intended use – the entire unit versus components

    •  Extremely high commitment to service, customer relationship

    •  Superior quality manufacturing

    •  Platinum personnel strategically located around the US and Canada

    •  Remote monitoring

    •  Centrally located

  • 8/20/2019 Technical Training Manual

    22/225

     

    22TECHNICAL TRAINING 

    SUPERIOR MANUFACTURING

    •  State-of-the-art ISO 9001:2008, CSA/UL certified facility

    •  Best quality assurance in the industry 

    •  Use only the highest rated component parts

    •  65,000 square feet of manufacturing space – virtually unlimited capacity to produce upon

    demand 

    •  Typically we can meet the demand for nearly any order quantity in days, not weeks, in

    conjunction with our distribution network 

    •  Main distribution hub and is centrally located near the Dallas-Fort Worth International Airport 

    The above three images are of Variosystems, Platinum’s manufacturer site.

  • 8/20/2019 Technical Training Manual

    23/225

     

    23TECHNICAL TRAINING 

    PLATINUM CONTROL BENEFITS

    •  Proven ability to integrate with the ROC system

    •  CSA/UL Certified for its intended use – the entire unit versus components

    •  Extremely high commitment to service, customer relationship

    •  Superior quality US manufacturing

    •  Platinum personnel strategically located around the US and Canada

    •  LBP network throughout the US and Canada

    •  Comprehensive technical training program

    •  Centrally located

    •  24/7 customer support hotline- 877-374-1115

  • 8/20/2019 Technical Training Manual

    24/225

     

    24TECHNICAL TRAINING 

    THE PLATINUM WAY

    We succeed. No Excuses.

    We strive to exceed our clients’ expectations.

    We provide our clients with excellent experiences.

    We solve our client’s problems, even if they are not directly our problems.

    We obsess about service.

    We don’t assume, we listen.

    We always operate with integrity.

    We are not always right. We admit it when we are wrong and act to solve the problem

    as quickly as possible.

    Success is never a solitary venture.

  • 8/20/2019 Technical Training Manual

    25/225

     

    25TECHNICAL TRAINING 

    SECTION II:

    COMBUSTION FUNDAMENTALS

  • 8/20/2019 Technical Training Manual

    26/225

     

    26TECHNICAL TRAINING 

    FIRE TRIANGLE

    Energy Energy is defined as the ability by work or heat to provide usable power.  

    It is our goal to incite usable power (energy) to affect a liquid or natural gas stream. The

    end result is to heat the stream to improve separation or to prevent hydrates from

    forming. The most common way to accomplish this is by using a burner system to affect

    (heat) the inlet stream.

    In this burner system a repeating chemical process known as combustion is occurring.

    There are three components that are required in specific ratios to create combustion. If

    any one of these three components are missing, or removed, then combustion cannot

    occur or be sustained.

    Oxygen Our atmosphere is composed of 20.9% Oxygen in most normal environments. This

    makes oxygen the most available component of the fire triangle. For our applications

    Oxygen is normally supplied to the burner by natural draft. The amount of oxygen

    available to the burner is critical in relationship to fuel. Therefore, the oxygen supply is

    usually regulated by a shutter, or mixing system combining the oxygen with fuel.

    Fuel 

  • 8/20/2019 Technical Training Manual

    27/225

     

    27TECHNICAL TRAINING 

    Fuel Many types of fuels can be used in the fire triangle. The primary fuels we will utilize are

    natural gas and propane. Both of these fuels are desirable for our application as little

    heat is required for ignition and the combustion process is controllable. In natural gas

    applications, the fuel supply is commonly provided from the working processes of the

    gas stream being generated at the location. There are times when this gas stream may

    be sent from an auxiliary location, or central battery. In some instances propane may be

    utilized. This occurs when there is little or no natural gas available for burner operations

    or the percentage of impurities in the gas stream such as CO2, H2S, etc. prevent burning

    the available gas. It is important to be sure of where the fuel stream is coming from, the

    type of fuel being used, and British Thermal Unit (BTU) value.

    Heat The final component of the triangle is energy (heat). We are seeking to provide this

    component to instigate the process of combustion. This is accomplished by utilizing an

    ignition source to generate the necessary heat to complete the chemical reaction. This

    component is most safely and conveniently provided by a Platinum Burner Management

    System (BMS) ignition device.

  • 8/20/2019 Technical Training Manual

    28/225

     

    28TECHNICAL TRAINING 

    CONTROLLED COMBUSTION

    We have established a goal of providing energy (heat) as a chemical treating process. It is then critical to

    be able to control this heat to insure safe and efficient operation. By providing the necessary ignition,

    and regulating the oxygen and fuel combination, we can harness available heat energy provided by the

    chemical reaction. This dictates that we must have the power to control initial ignition and the

    individual oxygen and fuel components brought together as a combined mixture. This control is

    imperative for a safe and sustained reaction.

    The ratio of oxygen to fuel for efficient operation can change subject to the BTU content. Without the

    proper ratio, the reaction can burn “rich” or “lean”. This affects the available heat energy, operation

    efficiency, sustainability, and maintenance issues relating to burner operation.

    Fuel 

    Oxygen 

    Heat 

    Heat 

    Exhaust 

  • 8/20/2019 Technical Training Manual

    29/225

     

    29TECHNICAL TRAINING 

    Control By Design

    Image of Platinum’s ignition module, wiring, and pilotinstalled in a flame arrestor.

    It is desired for the combustion chamber to be able to operate without the continuous assistance of

    personnel. Therefore, the combustion chamber, and supporting devices are designed to be operated

    with minimal field operator assistance. The primary assistance comes from startup operations providing

    the initial ignition source and adjustment of valves, regulators and oxygen/fuel mixing devices, and is

    not ongoing.

  • 8/20/2019 Technical Training Manual

    30/225

     

    30TECHNICAL TRAINING 

    Control By Instruments

    Dual Platinum BMS-731 units installed for glycol dehydrator

    and combustor. 

    Control of the ongoing heating process is required. Once again, it is desirable to minimize human

    contact. By utilizing electrical and pneumatic instrumentation for fuel supply and ignition, we can safely

    and efficiently decrease the need for personal attention and adjustment to the components utilized in

    burner operation.

    It is crucial that field personnel are aware and trained in the operation of the devices utilized on theirfield locations. There is a variety of components that may provide similar functions, but with different

    operating adjustment parameters. It is our recommendation for affected personnel to review the

    operations manuals for any component utilized. This is necessary to insure familiarity and an

    understanding of safe work practices related to each piece of equipment and the instrumentation

    associated.

  • 8/20/2019 Technical Training Manual

    31/225

     

    31TECHNICAL TRAINING 

    TYPES OF BURNER ASSEMBLIES

    Sketch of an average fired vessel.

    There are many different sizes, shapes, styles, and types of fired production equipment. We are

    primarily concerned with the most common types utilized in the oil and gas industry. These are direct

    fired and indirect fired.

    Emulsion Inlet 

    Gas Outlet 

    Oil Outlet 

    Water Outlet 

  • 8/20/2019 Technical Training Manual

    32/225

     

    32TECHNICAL TRAINING 

    Direct Fired Units

    Sketch of a direct fired heater already labeled. 

    In the operation of a direct fired device, the area of heat generated energy is directly in contact with the

    product to be affected. The heat contact is made in a fluid section. Examples of these types of

    production equipment would be emulsion heater treaters, heated separators, tank heaters, and glycoldehydration regen units.

    In a direct fired unit, the generated heat energy from the combustion chamber radiates from the

    firetube directly to the process stream to be affected, such as the inlet emulsion, or glycol to be

    recycled. Routine maintenance and inspections are recommended as extra precaution. This is due to

    the nature of the process fluid usually being flammable, and the direct proximity of the heat source.

    Water, Oil and Gas

    Emulsion 

    Clean Oil 

  • 8/20/2019 Technical Training Manual

    33/225

     

    33TECHNICAL TRAINING 

    Indirect Fired Units

    Sketch of an indirect fired heater already labeled. 

    In the operation of an indirect fired device, the area of heat generated energy is now providing heat

    energy to a media fluid. This media fluid, is heated, and transmits the heat energy to the process

    stream. This can be a gas or fluid stream. Examples of these types of production equipment would be

    water baths on gas production units, salt bath heaters, or line heaters.

    An indirect fired unit is an example of heat exchange in which heat is applied to one media, and then

    this heat is transferred to the process stream to gain the desired results.

    It is important to know whether the equipment being used is direct or indirect fired. This will assist in

    having a full understanding of safe, correct, and efficient operation.

    Gas or

    Emulsion

    Inlet

    Heated

    Outlet 

    Fluid Media 

  • 8/20/2019 Technical Training Manual

    34/225

     

    34TECHNICAL TRAINING 

    BURNER CATEGORIES

    The majority of fired equipment contains a fuel train, combustion chamber, the firetube, and stack. We

    will discuss the additional components which make up the fuel train and combustion chamber later.

    There are many different varieties of burner assemblies. The two most common are liquid fueled and

    gas fueled. For our purposes we are only concerned with gas fueled, and more specifically gas fueled

    natural draft burners.

    Liquid Fueled Burners These are burners that use oil, crude oil, diesel, gasoline, kerosene, etc. for

    burner fuel. The units are not typically practical in our area of operational

    requirements due to the availability and ease of operation of natural gas

    burners. In addition there is a requirement for forced oxygen supply and less

    stability resulting in more intensive equipment for operation. 

    Gas Fueled Burners There are two types of gas fueled burners usually found in petroleum industry

    production applications. These are forced draft and natural draft. 

    Forced Draft Burners Forced draft burners require a blower or fan to force oxygen through the air

    intake to be combined with fuel.

    The above image is of a forced draft burner on a horizontal

    heater. 

  • 8/20/2019 Technical Training Manual

    35/225

     

    35TECHNICAL TRAINING 

    Natural Draft Burners

    Platinum BMS-731 units installed on multi-well production units.

    This is the area of focus for us. Natural draft burners utilize oxygen supplied by the draft created due to

    the heat inside the firetube. The oxygen is drafted into the firetube through a flame arrestor

    (sometimes called burner front). The most commonly used fuel is natural gas produced on the site of

    the burner systems. There is a broad spectrum of usable natural gas from 850 BTU/scf to 1400 BTU/scf.

    The difference in supply gas BTU values will affect the heating capability of the burner. Propane may

    also be used as fuel for a natural draft burner. Propane has a higher heating value of 2512BTU/scf.

    When using propane, or high BTU natural gas, it may be necessary to reduce the fuel gas pressure up to

    40% , or reduce the orifice size up to 40% due to the higher heating value of propane. While not

    common, it is not out of the question to find landfill gases, or waste gases being burned in the

    petrochemical industry. The btu values of such gases can vary greatly, and may require using supplied

    propane to maintain a stable flame. It is essential to have a gas analysis to confirm heating value and

    combustibility to use landfill or waste gas as a supply.

    The most common type of burner found in the field in petrochemical applications is the gas fired natural

    draft burner. These burners are used for convenience and ease of operations. When properly sized and

    maintained gas fired natural draft burners will perform reliably. Key components are the fuel gas train,

    flame arrestor, burner mixer, burner nozzle, pilot mixer, pilot nozzle, burner management or ignition

    device, firetube, and stack. There are additional components that may be found on some installations

    such as secondary air adjustment, turbulators, shutters, combustion air controllers, but we will discuss

    these later. The burner should be sized according to the expected flow conditions of the location. It is

  • 8/20/2019 Technical Training Manual

    36/225

     

    36TECHNICAL TRAINING 

    always preferential to have a gas analysis and Btu content of the gas supply to be used. Note it is a

    common practice to move equipment from location to location as wells deplete. This can create a

    situation in which improperly sized equipment designed for a completely different set of conditions is on

    the site. This can result in poor heating capacity, unsatisfactory equipment performance, or even safety

    concerns.

    All natural draft burners operate on a gas fuel supply, and are not designed for liquid fuels. The fuel gas

    supply will flow from the source. This could actually be the equipment that the burner is situated on.

    An example would be a heat treater, or gas production unit. The gas supply flows through a scrubber to

    remove liquids, possibly a filter and/or a Y strainer to remove impurities, then to a pressure reducing

    regulator to maintain between 5 to 15 pounds average pressure, and then a fuel gas supply valve to

    allow for gas flow when required, and to shut gas flow off when not needed. A pilot gas supply is usuallytaken from the fuel gas scrubber as well; however this usually operates from ounces, possibly up to 8

    pounds (average 2-5 lbs.). In addition there can be relief valves, isolation valves, and gauges in the fuel

    gas train. The supply gas then goes into the combustion chamber to be mixed with oxygen which, is

    drafted into the firetube via the flame arrestor.

    There are a variety of brands of manufacture of all of the components in the fuel gas train and burner

    components in the combustion chamber.

    It is critical to have an understanding of correct burner adjustment procedures specific to the

    components being utilized to insure safe, reliable, and efficient burner performance. Proper burner

    tuning is essential to minimize heat release rate and allow for maximum combustion efficiency.

    There are several variables to be considered to allow for optimum burner adjustment:

    •  BTU content

    •  Confirm no impurities such as CO2 in gas supply stream

    •  Process volume through vessel

    •  Desired temperature for separation, prevention of hydrates

    •  Fuel gas pressure

    •  Unobstructed flame arrestor

    •  Firetube free of sooting, hot spots, paraffin buildup

    •  Orifice sizing

  • 8/20/2019 Technical Training Manual

    37/225

     

    37TECHNICAL TRAINING 

    •  Liquid in gas stream/plugging or freezing

    •  Primary air

    •  Requirement for secondary air

    •  Correct stack height

    •  Atmospheric conditions and elevation

    Correct operation of the burner will prevent excess cycling or excessive heat transfer. Both of these

    situations cause inefficient or wasted gas consumption.

    Thermal efficiency can be reviewed in some cases using a thermal heat gun. A complete analysis should

    be performed using a flue gas analyzer.

    Flue Gas Analyzer  

  • 8/20/2019 Technical Training Manual

    38/225

     

    38TECHNICAL TRAINING 

    TYPES OF OILFIELD EQUIPMENT WITH BURNER ASSEMBLIES

    Heater Treater 

    A vessel that heats an emulsion and removes water

    and gas from the oil to raise it to a quality acceptable

    for a pipeline or other means of transport. A heater

    treater is a combination of a heater, free-water

    knockout, and oil and gas separator.

    Electrostatic Treater

    A vessel that receives emulsion flows and resolves

    the emulsion to oil, water, and usually gas, by using

    heat, chemicals, and a high-voltage electric field.

    This field, produced by grids placed perpendicular to

    the flow of fluids in the treater, aids in breaking the

    emulsion. The electrostatic treater is also called the

    Chemelectric or electrochemical treater.

    Heated Separator

    An item of production equipment used to separate

    liquid components of the well stream from the

    gaseous elements. Separators are vertical or

    horizontal and are cylindrical or spherical in shape.

    Separation is accomplished principally by gravity, the

    heavier liquids falling to the bottom and the gas

    rising to the top. In this vessel a firetube or heating

    element has been added to prevent freezing or assist

    with emulsion separation.

  • 8/20/2019 Technical Training Manual

    39/225

     

    39TECHNICAL TRAINING 

    Glycol Dehydrator 

    A unit used to remove minute water particles from

    natural gas if dehydration has not been attained

    using separators. A glycol dehydrator unit is

    composed of an absorber, reboiler, and supporting

    components.

    Amine Unit

    An Amine Unit is a combination of a contactor

    tower, surge drum, regenerator, condenser, and

    accumulator assembled together with associated

    instrumentation for the removal of the acid gases

    CO2, H2S, plus additional contaminants from a

    natural gas stream. The sour gas is absorbed by

    Amine in the contactor tower. Hydrocarbon is

    separated from the solution in the surge drum. The

    acid gases are stripped from the “rich” amine in the

    regenerator. The now “lean” amine is circulated

    back to the contactor, while the acid gas and

    condensed liquids are sent to the condenser for

    cooling and then collected in the accumulator. This

    process can be found in both field and plant

    operations.

  • 8/20/2019 Technical Training Manual

    40/225

     

    40TECHNICAL TRAINING 

    Line Heater

    A container or vessel enclosing an arrangement of

    tubes and a firebox in which an emulsion is heated

    before further treating, or in which natural gas is

    heated in the field to prevent the formation of

    hydrates.

    Gas Production Unit 

    A unit that is a combination of a line heater, and a

    separator together on one skid or possibly

    enclosed housing. These units can also be referred

    to as “stack packs” and “T-packs”. More elaborate

    units can have multiple combinations housedtogether and may include dehydration equipment

    as well.

  • 8/20/2019 Technical Training Manual

    41/225

     

    41TECHNICAL TRAINING 

    Combustor 

    A device used to incinerate waste gas emissions

    VOCs (Volatile Organic Compounds), and BTEX

    (Benzene, Toluene, Ethyl Benzene, Xylenes)

    resulting from the production process. It

    eliminates and vaporizes these hazardous

    emissions by maintaining a certain temperature

    at the flash point. Maximum destruction

    efficiency is paramount.

    Combination Unit

    These units may be the combination of a gas

    production unit and a dehydration system

    combined on the same skid and enclosed.

  • 8/20/2019 Technical Training Manual

    42/225

     

    42TECHNICAL TRAINING 

    Multi-well Unit

    These units are essentially two or more gas

    production units on the same skid and are usually

    enclosed. They are designed for use on multiple well

    pad locations.

    Tank Heater

    These are firetubes designed to be mounted in the

    door of storage tanks. The units are found primarily

    in colder climates.

    Flare

    A device designed to ignite vent gas and other

    emissions. The flare does not have the destruction

    efficiency of an incinerator.

  • 8/20/2019 Technical Training Manual

    43/225

     

    43TECHNICAL TRAINING 

    THE FIRETUBE

    Sketch of firetube and components.

    The firetube is an integral part of the burner assembly. As discussed earlier, it allows for control by

    design. Without the firetube there would be no requirement for a burner assembly. While we are

    discussing fired vessels, it is important to note that fired vessels fall into a category of heated vessels.

    Not all heated vessels use an actual fire. We distinguish the equipment in our conversation as fired

    vessels, because they do in fact have a fire contained within the combustion chamber and firetube. The

    firetube itself houses the flame, a barrier from the process fluids or media, and provides for heat

    exchange. The heat produced in the firetube is communicated to the media or process fluids, thereby

    raising their temperature.

    Wildlife Protector

    Stack Arrestor 

    Turbulators 

    Flame

    Arrestor  Firetube Return

    Bend 

    Flange 

    Pilot Burner and Igniter 

    IgnitionModule 

    Main Burner 

  • 8/20/2019 Technical Training Manual

    44/225

     

    44TECHNICAL TRAINING 

    When properly adjusted, the flame in the firetube should not reach further than the beginning of the

    first bend of the firetube. It is an important consideration that the flame from the burner does not

    contact the firetube wall. Prolonged contact with the firetube wall can weaken the firetube causing

    “hot spots” or weak areas in the firetube that are subject to failure. If a firetube fails, the results could

    be catastrophic. A potential for explosion or fire would be possible if for example crude oil came in

    contact with the flame from the burner. A serious threat would be posed to safety, the environment,

    additional equipment, and revenue in the case of such an event.

  • 8/20/2019 Technical Training Manual

    45/225

     

    45TECHNICAL TRAINING 

    Heat Flow in the Firetube

    Once stabilized, the temperature of heat in the firetube is generally about the same as the temperature

    of the fluid surrounding the firetube. This is possible even when the temperature of combustion is far

    greater inside the firetube. This is due to the fact that heat exchanges from the firetube into the fluid

    faster than it moves from the combustion gas. Liquid is more dense than flue gas, allowing heat to

    move faster.

    Note in the illustration the heat flows from the hot gas through the firetube to become flue gas. Heat

    moves in the firetube from the inside to the outside. The metal firetube then absorbs and transfers heat

    to the liquid.

    Example of firetube heat transfer.

    Heat Transfer 

    Heat raises temperature

    of process. 

    Heat transfers through

    firetube shell. 

    Heat transfers from hot

    flue gas to firetube. 

  • 8/20/2019 Technical Training Manual

    46/225

     

    46TECHNICAL TRAINING 

    Example of firetube concerns.

    Example of carbon in the firetube.  Example of a hotspot in the firetube. Example of sooting inside of the firetube.

    Be very cautious of hot spots developing on the firetube, as well as scale or paraffin buildup on the

    outside of the firetube. This paraffin buildup will prevent heat transfer to the liquid, but will cause the

    metal to superheat and development of hot spots or weak points in the firetube.

    When liquid hydrocarbon is present, it will not completely burn. This results in coke forming inside the

    firetube. This coke will insulate the firetube and prevent well dispersed heat transfer. This will decreasethe bath temperature, and increase the stack temperature. Thereby efficiency is decreased.

    Sooting inside firetube.Hot spot in firetube. Scale or paraffin buildup

    on outside of firetube. 

  • 8/20/2019 Technical Training Manual

    47/225

     

    47TECHNICAL TRAINING 

    There are 4 different types of return bend designs for firetubes. It is worth noting that the square miter

    is the least expensive of the firetube designs, however it is the weakest. The longer the firetube leg,

    larger the diameter, and the more temperature cycling, the more susceptible to stress cracking the

    firetube becomes. It is also useful to note the firetube miter design for cleaning purposes and whether

    the firetube is a horizontal or vertical configuration.

    The Firetube Stack

    The stack is designed to incite oxygen flow or draft into the firetube via the flame arrestor. Due to this

    draft hot gases are expelled from the firetube via the stack. The design size and capacity of the

    combustion chamber and firetube dictate the height of the stack. The hot gases will rise ultimately to

    be dispersed outside the stack area. This creates a void in the firetube causing a lower pressure area

    around the burner. This allows the cooler oxygen to flow (draft) into the firetube and react in the

    combustion chamber. This process is integral to the ongoing chemical reaction of combustion taking

    place in the combustion chamber. The height of the stack, which may be between 10’ and 25’ long, is

    also designed to insure adequate stack drafting. Stack temperature can be monitored to prevent

    excessive heat loss or extreme fuel gas pressures to the main burner. Improper drafting can cause main

    and pilot burner flameouts, inefficient fuel consumption, poor combustion, and soot buildup.

    Square Miter 

    Firetube Return Bend Designs

    4 Miter Square Miter  Smooth Return 

  • 8/20/2019 Technical Training Manual

    48/225

     

    48TECHNICAL TRAINING 

    Flash Arrestor/Stack Head

    Flash arrestor/stack heads installed on production equipment.

    Not all fired vessels come equipped from the manufacturer with these devices. They are important

    considerations for safe and efficient operations. Flash and stack arrestors are designed to be mounted

    at the top of the firetube stack to prevent sparks, flashes, or any burning material from escaping the

    stack. Any escaping burning debris could ignite any combustibles that could be around or near the

    burner or stack assembly. Sparks are basically burning carbon remnants. An inefficient burner will

    generate the burning carbon. This carbon becomes attached to the firetube walls which can decrease

    drafting efficiency. This carbon can also crack, fall off, and re-ignite, potentially igniting any

    combustible material in proximity. The flash/stack arrestor can prevent these from escaping, but the

    burning carbon will cause soot buildup on the inside of the firetube, which leads to additional problems.

    The flash arrestor and stack arrestor are mounted on the stack head if the vessel is so equipped. These

    devices consist of an arresting element to prevent short duration sparks or flashes. These devices are

    designed of sufficient size to not add to backpressure on the stack which would prevent proper drafting.

    The stack head is utilized to minimize the possibility of pilot or main burner flame blowouts due to down

    drafts, or wind issues. Stack arrestor size must be at least as large as flame arrestor. Accurate sizing

    requires BTU requirement, firetube diameter, length, and stack height.

    NOTENot all fired production equipment is supplied with stack heads, stack arrestors, flash arrestors. Installation of these devices is

    usually determined by the producer, purchased from equipment manufacturer, and determined by state and federal land

    regulations.

  • 8/20/2019 Technical Training Manual

    49/225

     

    49TECHNICAL TRAINING 

    Turbulators

    Sketch of firetube and components.

    A firetube turbulator is a component installed in the second leg of the firetube past the return bend.

    The purpose of the turbulator is increase heat transfer on the back side of the firetube. The turbulator

    directs flue gas outward towards the wall of the firetube. This increases heat retention and heat

    transfer from the firetube, lowers stack temperatures, decreases pressure loss, increases efficiency,

    while decreasing operating expense.

    Wildlife Protector

    Stack Arrestor 

    Turbulators 

    Flame Arrestor  Firetube RetuFlange 

    Main Burner 

    Pilot Burner and Igniter 

    Ignition

    Module 

  • 8/20/2019 Technical Training Manual

    50/225

     

    50TECHNICAL TRAINING 

    THE COMBUSTION CHAMBER

    Sketch of combustion chamber and components.

    The combustion chamber is the front end portion of the firetube adjoined with the flame arrestor. This

    is where oxygen from outside the firetube is combined with the supplied pilot and main burner gas for

    ignition and sustained combustion. The combustion chamber consists of piping coming in to the

    chamber from the fuel gas train, the pilot orifice, mixer and nozzle, the main mixer, and burner nozzle,

    in addition to burner ignition components. It is recommended the burner nozzle extend from the flame

    cell into the firetube 4”.

    Inspection

    Port 

    Hood 

    Flame 

    Arrestor 

    Pilot Gas 

    Fuel Gas 

    Burner

    Nipple Burner Mixer 

    Burner

    Nozzle 

    Pilot Nozzle Pilot Nipple Pilot Mixer 

    High VoltageCable 

    Ground

    Cable 

    Ten-Conductor

    Cable 

    Ignition

    Module 

    Igniter Rod 

    Air 

    Flow 

    Air 

    Flow 

    Flange 

  • 8/20/2019 Technical Training Manual

    51/225

     

    51TECHNICAL TRAINING 

    Flame arrestor orientation and installation. 

  • 8/20/2019 Technical Training Manual

    52/225

     

    52TECHNICAL TRAINING 

    The Flame Arrestor

    Sketch of flame arrestor and components.

    The purpose of the flame arrestor is to insure that combustion stays in the combustion chamber. In

    case of an explosion, the flame arrestor cools the vapors from inside the combustion chamber to

    prevent a potential ignition on the outside of the arrestor. The flame arrestor is the shell that holds the

    flame cell. The flame cell is a tortuous path of passages that serves as heat exchanger. This path arrests

    all flames providing safety and protection. The flame cell is sized to deliver an excess air level of 15

    percent considering the lowest draft amount available for ignition and sustained reaction. This also

    serves to dissipate the heat generated internally in the combustion chamber to below ignition

    temperature on the outside of the flame arrestor. The flame arrestor flame cell or element is

    engineered with sufficient mass to endure being positioned near the burning flame inside the

    combustion chamber.

    It is important to know that there are two different types of combustions that occur within a

    combustion chamber near the flame arrestor. These two types of combustions are deflagration and

    detonation. The controlled burning that takes place at the burner tip is known as deflagration. A

    substantial flame velocity fed by high internal pressures with extreme gas turbulence is known as

    detonation.

    Inspection 

    Port 

    Burner Mixer 

    Gas Inlet 

    Flame Arrestor Housing Firetube Flange 

    Burner Nozzle 

    Pilot Nozzle 

    Pilot Mixer 

    Burner Mixer 

    Flame Arrestor 

  • 8/20/2019 Technical Training Manual

    53/225

     

    53TECHNICAL TRAINING 

    The flame arrestor element is designed to withstand explosions (detonations) in the firetube or prevent

    flashes from passing through the element that could potentially ignite outside the flame arrestor. To do

    so the wrap density of the flame arrestor must be sufficiently tight utilizing alternating wraps of flat and

    corrugated metal. The flame arrestor housing is engineered with the same considerations in mind. In

    addition, considerations are made in regards to the design being able to withstand adverse hot and cold

    weather conditions. Most modern flame arrestors are made of aluminum or stainless steel in offshore

    applications. In the past arrestors were made of carbon steel, and many of these are still in service.

    Gaskets used between all jointed components of the flame cell are critical. These gaskets must be in

    good shape and provide a seal to prevent fugitive combustible material from exiting the flame arrestor

    area.

    It is recommended to service flame arrestors and the combustion chamber on a regular basis to bedetermined by the equipment usage. It is important to inspect these components for damage, plugging,

    debris, wear, holes, leaks, etc…..

  • 8/20/2019 Technical Training Manual

    54/225

     

    54TECHNICAL TRAINING 

    Benefits of Flame Arrestors 

    Flame arrestor disassembled. 

    Flame arrestors have not always been used, and it is possible to find vessels in the field that still do not

    have flame arrestors on them. These have what was called a burner front. These can be dangerous as

    an open flame may be exposed. These units should be replaced for safety and to be compliant with

    regulations in most areas.

    The flame arrestor itself provides many benefits:

    •  Ease of inspection and cleaning.

    •  Corrosion resistant.

    •  Explosion resistant retaining band which when maintained allows for a long service life.

    •  Designed to prevent debris and other materials from entering the firetube.

    •  Provides a measure of dampening of burner noise.

    •  Decreases potential for downdrafts or wind to blow out the burner or pilot flame.

    •  Total combustion of fuel gas by providing steady oxygen feed to the main and pilot burners.

    An important additional component of the flame arrestor is the inspection port. The inspection port is

    typically on the front of most modern flame arrestors and may contain a temperature resistant window.

    This port is beneficial for inspection of flame, burner components, and can assist in troubleshooting.

    NOTENEVER REMOVE INSPECTION PORT COVER WHILE A FLAME IS PRESENT IN THE COMBUSTION CHAMBER. A HAZARDOUS

    FLASHBACK CAUSING INJURY COULD RESULT.

  • 8/20/2019 Technical Training Manual

    55/225

     

    55TECHNICAL TRAINING 

    Types of Flame Arrestors

    There are a variety of flame arrestor types, brands of manufacture, and sizes. We will illustrate some of

    the more common below. Examples are of the T-Type, O-Type, Barrel Type, and A-Type.

    T-Type flame arrestor on horizontal treater.  O-Type flame arrestor on gas production unit.

    Barrel/Box Type flame arrestor on line heater. A-Type flame arrestor on line heater.

    T-Type 

    O-Type  Barrel-Type  A-Type

     

  • 8/20/2019 Technical Training Manual

    56/225

     

    56TECHNICAL TRAINING 

    Flame Arrestor Operations

    The flame arrestor is a valuable safety device. To remain an asset, and not turn into a liability, the flame

    arrestor must be in good operation condition with maintenance performed regularly.

      Inspect regularly as determined by usage, weekly, monthly, quarterly, semi -annual.

      Confirm the flame arrestor element is free of plugging, oily residue, sand, soot, corrosion, etc…

      Look for signs of warping or heat damage.

      Insure firetube is free of sooting, obstructions, or hot spots

      Check positioning of burner equipment.

      Check gas flow through main and pilot burners.

      Check and test thermostats.

      Inspect gaskets, and observe sealing surfaces and seams for integrity.

      Always use new gaskets when performing maintenance or repairs.

      Clean flanges before re-assembly during maintenance.

      Flame arrestor and firetube joint seal must be airtight.

      All seams on firetube must be free of pinholes or cracks.

      Make sure sight glass cover is clean with no cracks.

      Be sure inspection cover is in place and sealed.

      Make sure there are no additional ignition sources near flame arrestor.

      Remove any flammable materials from the area around flame arrestor.

      Inspections of fuel gas supply and fuel gas train should be conducted at this time.

      Inspect and clean any additional flame or stack arrestors at this time.

    CONSULT API RP 12N FOR OPERATION, MAINTENANCE, AND TESTING OF FLAME ARRESTORS

  • 8/20/2019 Technical Training Manual

    57/225

     

    57TECHNICAL TRAINING 

    Standard Flameco Nomenclature

    STANDARD A TYPE F/A SIZES

    A Type (Flameco “O” Type)

    MM Btu/Hr. Standard Model # Mixer Style

    0.05 SB 12-6-1 Mixer Head

    0.10 SB 12-6-1 Mixer Head

    0.25 SB 12-8-1-1/2 Mixer Head

    0.40 SB 16-8-2 Mixer Head

    0.50 SB 16-8-2 Mixer Head

    0.75 SB 20-10-3SS Single Stage

    1.00 SB 24-12-3SS Single Stage

    1.25 SB 26/18-14/3CI Compound

    1.50 SB 28/18-14/3CI Compound

    1.75 SB 32/18-20/4SS Compound2.00 SB 34/18-20/4SS Compound

    Box Type Flame Arrestor

    2.50 SB 30-20B-4CI Compound

    3.00 SB 32-20B-5CI Compound

    3.50 SB 36-24B-5CI Compound

    4.00 SB 38-24B-5CI Compound

    4.50 SB 40-24B-5CI Compound

    5.00 SB 30-18B-4CI Two Compound

    6.00 SB 32-20B-5CI Two Compound

    7.00 SB 36-24B-5CI Two Compound

    NOTE:Low noise burner applications use the same arrestor, mixer and nozzle combinations, but use a larger orifice.

    Firetube Count 

    Compound Mixer 

    Burner Size 

    Box Type 

    Firetube Size 

    Body Length (12” is Standard) 

    Element Diameter 

    Single Burner 

    MB-MultiBurner

    SB 12 / 16 – 6B 1CI (TWO) -

  • 8/20/2019 Technical Training Manual

    58/225

     

    58TECHNICAL TRAINING 

    MAIN & PILOT BURNER ASSEMBLIES

    Sketch of flame arrestor with burner components.

    The burner assembly housed inside the flame arrestor/combustion chamber is made up of the following

    components:

    •  Fuel gas supply nipple

    •  Main gas primary air mixer

    •  Main gas burner nipple

    •  Main gas burner nozzle

    •  Pilot gas supply nipple or tubing

    •  Pilot gas orifice

    •  Pilot gas mixer

    •  Pilot gas burner tip

    Inspection

    Port 

    Hood 

    Flame 

    Arrestor 

    Pilot Gas 

    Fuel Gas 

    Burner

    Nipple Burner Mixer 


Recommended