+ All Categories
Home > Documents > TechnicalDatasheet IntelligentJunctionBox ModelJBI-2 · Cable network status indication is provided...

TechnicalDatasheet IntelligentJunctionBox ModelJBI-2 · Cable network status indication is provided...

Date post: 24-Mar-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
1
IntelligentJunctionBox ModelJBI-2 WarningandDisclaimer Theinformationandrecommendationsinthisdocumentareprovidedforreferencepurposesonlyandshouldnotbeconstruedasadviceto covereveryapplicationoftheproductorvariationofconditionsunderwhichtheproductmaybeused. TechnicalDatasheet Specifications Features Integrated LED for cable status monitoring. It continuously indicates the state of the Centralized Blasting cable network. This unit facilitates the interconnection of up to four blasting network cables. Cable network status indication is provided when used in conjunction with the Centralized Blasting Controller Model CBC-1 or CBC-2. Operation Up to four cables can be inter-connected via the Junction Box in parallel. Cable entry is via 20mm No. 1 or No. 2 glands. Blanking plugs are provided for unused cable entries. All service work to be performed by authorised AEC Electronics personnel only. Not approved for use in fiery mines. NoticeandMaintenance Enclosure Glassre-inforcedpolyestercompound,IP68rated. SupplyVoltage 30-60V incablemonitoringmode; Modified160-250V infiringmode. DC AC Facilitates parallel connection of up to four blasting network cables with status indication when used in conjunction with Centralized Blasting Controller Model CBC-1 or CBC-2. Function UnitMass 0.53kg. OutsideDiameter:110mm. Height:74mm. UnitDimensions CableEntry Uptofour20mmNo.1orNo.2glands.Unusedentriessealedwith removableplugs. Lid Transparentpolycarbonate. FLASHES at about 1s intervals in cable monitoring mode if the supply cable network is in working order. OFF if there is an open circuit fault in an upstream supply cable network or short circuit at any point on the Centralized Blasting System cable network. ON when firing takes place. SupplyLight UnitDimension 110mm 74mm E-XPS/11191. IA CertificateNumber AECElectronics(Pty)Ltd Tel:+2711975-1643Fax:+2711975-1680 Email:[email protected]://www.aece.co.za P.O.Box958,KemptonPark,1620,South Africa
Transcript
Page 1: TechnicalDatasheet IntelligentJunctionBox ModelJBI-2 · Cable network status indication is provided when used in conjunction with the Centralized Blasting ControllerModelCBC-1orCBC-2.

Intelligent�Junction�BoxModel�JBI-2

Warning�and�DisclaimerThe�information�and�recommendations�in�this�document�are�provided�for�reference�purposes�only�and�should�not�be�construed�as�advice�to

cover�every�application�of�the�product�or�variation�of�conditions�under�which�the�product�may�be�used.

Technical�Datasheet

Specifications

Features

� Integrated LED for cable status monitoring. Itcontinuously indicates the state of the CentralizedBlasting cable network.

This unit facilitates the interconnection of up to fourblasting network cables.Cable network status indication is provided whenused in conjunction with the Centralized BlastingController Model CBC-1 or CBC-2.

Operation�

Up to four cables can be inter-connected via theJunction Box in parallel.Cable entry is via 20mm No. 1 or No. 2 glands.Blanking plugs are provided for unused cableentries.

All service work to be performed by authorised AECElectronics personnel only.Not approved for use in fiery mines.

Notice�and�Maintenance

Enclosure Glass�re-inforced�polyester�compound,�IP68�rated.

Supply�Voltage30-60V in�cable�monitoring�mode;

Modified�160-250V in�firing�mode.DC

AC

Facilitates parallel connection of up to four blasting network cables

with status indication when used in conjunction with Centralized

Blasting Controller Model CBC-1 or CBC-2.Function

Unit�Mass 0.53kg.

Outside�Diameter:�110mm.

Height:�74mm.Unit�Dimensions

Cable�EntryUp�to�four�20mm�No.1�or�No.�2�glands.�Unused�entries�sealed�with

removable�plugs.

Lid Transparent�polycarbonate.

FLASHES at about 1s intervals in cable monitoring mode if the

supply cable network is in working order.

OFF if there is an open circuit fault in an upstream supply cable

network or short circuit at any point on the Centralized Blasting

System cable network.

ON when firing takes place.

Supply�Light

Unit�Dimension

110mm

74mm

E-XPS/11191.IA Certificate�Number

AEC�Electronics�(Pty)�Ltd

Tel:�+27�11�975-1643���Fax:�+27�11�975-1680Email:�[email protected]���http://www.aece.co.za

P.O.Box�958,�Kempton�Park,�1620,�South AfricaAEC�Electronics�(Pty)�Ltd

Tel:�+27�11�975-1643���Fax:�+27�11�975-1680Email:�[email protected]���http://www.aece.co.za

P.O.Box�958,�Kempton�Park,�1620,�South Africa