The Telaris ProInstall-100-DK Multifunction Installation Tester verifies the safety of electrical installations in residential, commercial and industrial applications. It has been developed to carry out measurements in accordance with regulation. Telaris Multifunction Electrical Installation Tester www.Amprobe.eu Telaris ProInstall-100-DK • Tests electrical installations for safety in accordance with EN 61557, BS7671 and IEC 60364 • Lightweight and compact for portability • Easy to use, intuitive interface allowing you to work immediately and efficiently • Insulation resistance measurements up to 1000V DC • Fast loop measurements with high test current • No trip loop test, does not trip RCDs • Easy to read, large back lit LCD display with wide viewing angle • Data logging capabilities downloadable to a PC For detailed specifications and ordering info go to www.Amprobe.eu 6001114 A ©2013 Amprobe. All rights reserved. TELARIS PROINSTALL-100-DK MEASUREMENT PARAMETERS Specifications ProInstall-100-DK Voltage & frequency display Low Ohm resistance Insulation resistance Loop/line test Loop impedance without tripping RCDs PSC (short-circuit current) RCD trip time RCD trip current (ramp function) Test AC and pulsed AC sensitive RCDs (Type AC, type A) Phase sequence test Illuminated display Memory For more detailed specifications see users manual.
Transcript
Page 1: Telaris Multifunction Electrical Installation TesterAmprobe® info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE (267-7623) Amprobe® Europe In den Engematten 14, 79286 Glottertal,

The Telaris ProInstall-100-DK Multifunction Installation Tester verifies the safety of electrical installations in residential, commercial and industrial applications. It has been developed to carry out measurements in accordance with regulation.

Telaris Multifunction Electrical Installation Tester

www.Amprobe.eu

Telaris ProInstall-100-DK

• TestselectricalinstallationsforsafetyinaccordancewithEN61557,BS7671andIEC60364

• Lightweightandcompactforportability

• Easytouse,intuitiveinterfaceallowingyoutoworkimmediatelyandefficiently

• Insulationresistancemeasurementsupto1000VDC

• Fastloopmeasurementswithhightestcurrent

• Notriplooptest,doesnottripRCDs

• Easytoread,largebacklitLCDdisplaywithwideviewingangle

• DataloggingcapabilitiesdownloadabletoaPC

For detailed specifications and ordering info go to www.Amprobe.eu 6001114A©2013 Amprobe. All rights reserved.

TelarIs PrOINsTall-100-DK MeasureMeNT ParaMeTersSpecifications ProInstall-100-DK

Voltage&frequencydisplay ■

LowOhmresistance ■

Insulationresistance ■

Loop/linetest ■

LoopimpedancewithouttrippingRCDs ■

PSC(short-circuitcurrent) ■

RCDtriptime ■

RCDtripcurrent(rampfunction) ■

TestACandpulsedACsensitiveRCDs(TypeAC,typeA) ■

Phasesequencetest ■

Illuminateddisplay ■

Memory ■

For more detailed specifications see users manual.

Page 2: Telaris Multifunction Electrical Installation TesterAmprobe® info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE (267-7623) Amprobe® Europe In den Engematten 14, 79286 Glottertal,

www.Amprobe.eu

PrOINsTall-100-DK DeTaIleD sPecIfIcaTIONs

AC Voltage Measurement L-N, L-PE , N-PE

Display range ResolutionIntrinsic accuracy

50Hz – 60hzMeasurement range Operating error Input impedance

Overload protection

0 - 500V 0,1V ± (2% + 2D) 50 – 500Vac ± (3% + 3D) 3,3MΩ / 360 kΩ 600 Vrms

Continuity Measurements

Display range(auto-ranging)

Resolution Intrinsic accuracy Measurement range Operating error Test currentOpen circuit

voltage

0 - 20 Ω 0,01 Ω

± (3% + 3D) 0,30 - 2000 ± (10% + 3D)> 200 mA for Rlo < 2 Ohms

> 4V200 Ω 0,1 Ω

2000 Ω 1 Ω

Insulation Resistance Measurements

Test voltage Display range Resolution Test currentIntrinsic accuracy

Measurement rangeOperating

errorAccuracy of test voltage

at max. 1mA load

100 V0 MΩ to 20 MΩ

20 MΩ to 100 MΩ 0,01 MΩ0,1 MΩ

1 mA @ 100 kΩ± (5% + 5 dgt.)

0,1 MΩ to 20 MΩ20 MΩ to 200 MΩ

± (12% + 3D)

+20%, -0%

250 V0 MΩ to 20 MΩ

20 MΩ to 200 MΩ1 mA @ 250 kΩ

0,25 MΩ to 20 MΩ20 MΩ to 200 MΩ

500 V0 MΩ to 20 MΩ

20 MΩ to 200 MΩ200 MΩ to 500 MΩ

0,01 MΩ0,1 MΩ1 MΩ

1 mA @ 500 kΩ ± (5% + 5 dgt.),For R > 200 MΩ

±10%

0,5 MΩ to 20 MΩ 20 MΩ to 200 MΩ

200 MΩ to 500 MΩ

± (12% + 3D) ± (12% + 3D) ± (15% + 5D)

1000 V0 MΩ to 200 MΩ

200 MΩ to 1000 MΩ0,1 MΩ1 MΩ

1 mA @ 1 MΩ1 MΩ to 200 MΩ

200 MΩ to 1000 MΩ± (12% + 3D)± (15% + 5D)

Impedance Measurements

Display range(auto-ranging)

Resolution Intrinsic accuracy Measurement range Operating error

0 - 20 Ω 0,01 Ω± ( 4% + 5 dgt.) no trip*

± ( 3% + 3 dgt.) high currentNotripmode 0,50 – 2000 Ω ± (15% + 8D) *

200 Ω 0,1 Ω ± 5% Hicurrentmode 0,30 – 200 Ω ± (10% + 5D)

2000 Ω 1 Ω ± 6% * Valid for resistance of neutral circuit < 20 Ohms

PSC Test

Computation PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance.

Range 0 – 10 kA

ResolutionandUnits IK < 1000 A; 1 A / IK > 1000 A; 0,1 A

Accuracy Determined by accuracy of Loop Resistance and Mains Voltage measurements.

RCD Testing

Types of RCDs tested

RCDTypeProInstall-100-DKAC(RespondstoAC)*

A(Respondstopulsedsignal)G(General,nodelay)S(Timedelayed)

AC G ■AC S ■A G ■A S ■

*1000mA for type AC only Voltage range: 100 … 264 VAC

For detailed specifications and ordering info go to www.Amprobe.eu 6001114A©2013 Amprobe. All rights reserved.

Page 3: Telaris Multifunction Electrical Installation TesterAmprobe® info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE (267-7623) Amprobe® Europe In den Engematten 14, 79286 Glottertal,

Amprobe® [email protected], WA 98203Tel: 877-AMPROBE (267-7623)

Amprobe®Europe In den Engematten 14, 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0

For detailed specifications and ordering info go to www.Amprobe.eu 6001114A©2013 Amprobe. All rights reserved.

www.Amprobe.eu

RCD Test, Tripping Speed

Current settings** Multiplier Current accuracy RCD type* Test time (max)

10, 30, 100, 300, 500, 1000 mA x 1 +10% -0% G 300 ms.

10, 30, 100, 300, 500, 1000 mA x 1 +10% -0% S 500 ms.

* G = General S = Delayed-action RCD** For 1000mA setting type AC RCDs only, trip time measurement only (no ramp test)

RCD Test, Tripping Speed

Current settings Multiplier Current accuracy

10, 30, 100, 300, 500, 1000 mA* x ½ +0% -10% of test current

10, 30, 100, 300, 500, 1000 mA * x 1 +10% -0%

10, 30, 100 mA, Auto x 5 ±10%

*For 1000mA setting type AC RCDs only

Current multiplier RCD typeMeasurement range Trip time

intrinsic accuracyTrip time operating error

Europe UK

x ½ G 310 ms. 2000 ms.

+ ( 2% + 2 D) ± ( 10% + 2 D)

x ½ S 510 ms. 2000 ms.

x 1 G 310 ms. 310 ms.

x 1 S 510 ms. 510 ms.

x 5 G 50 ms. 50 ms.

x 5 S 160 ms. 160 ms.

RCD Test, Tripping Current Measurement (Ramp Test) ( I PN )

Current range Step sizeDwell time Trip current

intrinsic accuracyTrip current operating error

Type G Type S

50% to 110% ofRCD’s rated current

10% of I PN 300 mS / step 500 mS / step ± 5% ± ( 10% + 2 D)

Phase Sequence Indication

Displayofphasesequence Indicates “1-2-3” in digital display field for correct sequence. Indicates 3-2-1 for incorrect phase.

Missingphaseindication Missing phase indicated by dash in place of number on numeric display.

General Specifications

Powersupply6 x 1.5 V batteries type IEC LR6 (AA)6 x 1.2 V NiMH rechargeable batteries

Degreeofpollution 2

Overvoltagecategory CAT III 500 V / CAT IV 300V

Protectiondegree IP40

Protectionclass II

Electricalsafety EN61010-1/VDE0411

EMCinterferenceresistance EN61326-1

Dimensions(LxWxH) Approximately 115 x 255 x 130 mm

Weight Approximately 1450 g