TelevisGo
MA
NA
GEM
ENT
AN
D M
ON
ITO
RIN
G
Monitoring and Control have never been this easy
QUICKSTART
ConTenTS
1. InTRoDUCTIon .................................................................................................. 31.1 INTRODUCTION ............................................................................................................................................................31.2 SYSTEM REQUIREMENTS .............................................................................................................................................3
2. MeCHAnICAL InSTALLATIon ............................................................................ 42.1 GENERAl wARNINGS ..................................................................................................................................................42.2 PACkAGE CONTENTS ..................................................................................................................................................42.3 MEChANICAl INSTAllATION ....................................................................................................................................42.4 CONNECTIONS ON ThE DEvICE ..............................................................................................................................4
3. InSTALLATIon ..................................................................................................... 53.2 wEB INTERfACE ............................................................................................................................................................5
3.2.1 DEvICE SETTINGS .........................................................................................................................................................................................................................5
3.2.2 NETwORk SETTINGS ...................................................................................................................................................................................................................6
4. WARnInGS .......................................................................................................... 84.1 RESPONSIBIlITY AND RESIDUAl RISkS....................................................................................................................84.2 DISClAIMER ....................................................................................................................................................................8
TelevisGo Page 3/9
1.1 InTRoDUCTIonThis guide contains all the general information needed for the installation and initial start-up of TelevisGo. for all other settings and options, see the full technical documentation on the CD-ROM.You are urged to follow the instructions carefully to ensure that the installation and initial start-up of the software are done correctly.
1.2 SYSTeM ReQUIReMenTSThe main technical features of TelevisGo are listed below:
• Power supply: DC12V with external 100-240 Va ±10%, 50-60 Hz power unit.• Max. power absorbed: 10 VA• Ambient working temperature: 0 … 50°C• Ambient storage temperature: -20 … 60°C• Operating/storage humidity: 10...90% (non condensing)• Maximum number of connectable devices: 224• Operating System: XP Embedded (English language)
(the license number card is inside the packaging)
• Connectivity: Ethernet (lAN), external GSM modem (RS232 interface based on SIEMENS type TC35 technology) and integrated USB ports.
• languages supported:• Italian• English• Spanish• German• french
• Browsers supported:• Internet Explorer 7 or later• Mozilla firefox 3.5 or later
• Types of network that can be monitored:• RS-485 network• TCP/IP network
1) Sample RS-485 network 2) Sample TCP/IP network
Bus Adapter
Bus Adapter
Radio Adapter
RS485uNet
RS485
TCP/IP
100...240 V~
Alimentazione
uNet
Ethernet RS-485
noTe: Signal propagation in a TCP/IP (Ethernet) network depends on bus traffic, which can make access times to the lanAdapter non-deterministic and influence access times to the RS485 sub-net.
The SerialAdpater232 adapter can only be connected to CoM1 or CoM2 as it is supplied by them. Other serial accessories (modems) must be connected to serials COM3 or COM 4.
1. InTRoDUCTIon
TelevisGo Page 4/9
2.1 GeneRAL WARnInGS
IMPoRTAnT! Always make sure the device is disconnected (unplug power cable) before touching connections. All operations must be carried out by qualified personnel.
Do not assemble devices in extremely damp and/or dirt-laden areas; they are designed for use in places with ordinary or normal levels of contamination. Make sure the area near the cooling slots is ventilated.The admissible ambient temperature range for correct operation is between –5°C and +40°C.Modules and system devices must be connected using a cable with 0.5 mm2 conductors. There must be no more than 2 km between TelevisGo and the last module. Remember to insert a 120Ω, ¼w resistor between the “+” and “-“ terminals of the last device in the network.
noTe: Comply with relevant applicable legislation when laying data transmission cables.
2.2 PACKAGe ConTenTSThe package contains:
• TelevisGo device• Power unit and power cable• CD with manuals, list of compatible devices and examples of how to upgrade device
2.3 MeCHAnICAL InSTALLATIonTelevisGo was designed for wall or panel-mounting.Secure the device to the wall/panel with 4 screws (not supplied) to match the holes illustrated in the figure below.
274.00 mm
155.
00 m
m
Hole A
Hole C
Hole B
Hole D
2.4 ConneCTIonS on THe DeVICeThe following connections are to be found on the front and back of the controller:
VGA USB USB
COM3
LAN COM2
COM4
KBD
240.00 mm
1
2
34
5 6
7 8
9
10
11
12
13
14
1) 12v DC power supply connection2) COM1 (RS232) port3) vGA monitor connection4) 4 USB connections5) COM3 (RS485) port6) COM4 (RS485) port7) lAN RJ45 connection8) COM2 (RS232) port9) PS2 keyboard connection10) lED power supply and hDU11) 2 USB connections12) Audio minijack socket13) PowerON/powerOff button14) Not used
2. MeCHAnICAL InSTALLATIon
TelevisGo Page 5/9
To install TelevisGo, you have to set up the device and the network of devices it is connected to first. This can be done via the wEB interface.
noTe 1: Before scanning the network with TelevisGo,each device in the network must be assigned a unique address by setting parameters “fAA” and “dEA”.
noTe 2: To switch the device off, press and hold button (13) for 4 seconds (a safety feature to prevent accidental switching off). In the event of a blackout, the PC and application restart automatically when mains power is returned.
3.2 WeB InTeRfACe TelevisGo must be switched on and connected to the internet to access the wEB interface.Open a compatible browser and enter the device address:
http:// <TelevisCompact IP Address: Porta>
The factory-set parameters are as follows:
<TelevisCompact IP Address> = 192.168.50.50 Subnet mask: = 255.255.0.0
To make sure the connection between your PC and TelevisGo works, configure the PC with an IP address that is compatible with the TelevisGo subnet mask (contact the network administration for further information).
n.B.: for port 80, this can be omitted, otherwise it must always be indicated (e.g. http://192.168.50.50:2010).
when switched on, TelevisGo runs a system check then shows the login screen (fig. 3). Set the language, and enter the default user profile (User Name: Administrator and Password: 0) and press enter.The welcome page opens (fIG. 4).
fIG. 3 fIG. 4
User name:
Plant name:Televis Go
Versione 5.0.0.0
Password:
User interface language:
Save this info
English
Administrator
Login
TelevisGo
TelevisGo
Eliwell Controls
Software version: 5.0.0.0
O.S. version: 5.0.0
Boot loader compatible version: 5.0.0.0
Interface identifier: 0
Page last update on: 7.39.34
Plant identification Networks found
Devices 15
Interface identifier: 999Devices 1
Device number: 16
60Maximum number of devices:
Televis Go
Informazioni
Data » Overview
Alarms ComputerSettingsToolsData
Overview Real time table Historical table Historical chart Energy report Energy chart
welcome page
3.2.1 DeVICe SeTTInGSThe main settings are:
Date&Time: Go to Computer Information General (fIG. 5).
Click Modify, Set Date and Date/time then click Save.
Plant name: Go to Computer Information General (fIG. 5 - optional but recommended).
Click Modify, enter the Plant Name then click Save.
network IP/DnS: Go to Computer Information network settings (fIG. 6).
Click Modify, enter Network Data (contact the network administrator) then click Save.
3. InSTALLATIon
TelevisGo Page 6/9
fIG. 5 fIG. 6
Page last update on: 7.39.34
Computer » Information » General
Network settings General
General
Plant name
Date (yyyy-mm-dd)
Time (hh:mm)
Edit Save Cancel
2010
Televis Go
10 21
7 57
Use client date/time
KeY: = Modify data
= Save data
= Cancel changesPage last update on: 7.39.34
Computer » Information » Network settings
Alarms ComputerSettingsToolsData
General
Information Upgrade Reboot Update license
Network settings
IP Address
Obtain an IP address automatically (DHCP)
Use the following IP adress:
IP Address
Edit Save Cancel
Subnet mask
Gateway
DNS
10 39 4 103
255 255 255 0
Obtain the DNS server IP address automatically
Use the following server DNS addresses:
Preferred DNS server:
Alternate DNS server:
10 39 4 15
10 39 4 16
10 39 4 12
:
Proxy Settings
Proxy - SOCKS - Domain resolution
Proxy - Ignore local addresses
Proxy - Enabled
Proxy - Protocol
Proxy - Server address
Proxy - Server port
Proxy - User
Proxy - Password
Native DNS
SOCKS 5
3.2.2 neTWoRK SeTTInGSThe following must be set:
Interfaces: Go to Settings Interfaces Scan
Now click Manage Interfaces ( ). In the window that opens, click Add ( ) and enter:
• Interface type: Serial Adapter (fIG. 7) or lanAdapter (fIG. 8)• Protocol: Micronet or Mixed (Micronet + Modbus)• fieldbus: network types (BusAdapter, lanAdapter, lanAdapter + wifi, lANAdapter Radio + RadioAdapter,
RadioAdapter and SmartAdapter)• IP Address: enter the device IP address.• Port: PC communication port used by the device then click Save ( ).
Scan: Go to Settings Interfaces Scan
On saving interfaces, set the scan range using pop up menus 1, 2, 3 and 4. To start scanning network devices, click next ( ) (fIG. 9).
On completion of the scan, a window opens listing all devices located (fIG. 10). The first line identifies the network scanned. The second and subsequent lines list devices associated to the network.
New devices located are shown in green, existent ones are shown in white and devices which were not located and which may no longer be visible are shown in grey.
On completion, press Save to save all data logged.
fIG. 7 fIG. 9
Interfacetype
Fieldbus
Details
SerialAdapter
LanAdapter
Port
Protocol
BusAdapter
Micronet
Page last update on: 7.39.34
Select all Deselect all Manage Interfaces
LAN Adapter
Interface ID Address Fieldbus Discovery range
0 192.168.0.1 From to00LanAdapter 00 14 14
NamingOut of networkDiscoveryView
1 2 3 4
fIG. 8 fIG. 10
Interfacetype
Fieldbus
Details
SerialAdapter
LanAdapter
Address
Port
Protocol
LanAdapter
Micronet
56789
192 168 1 1
LAN Adapter
Interface Interfaceidentifier DevicesAddress
0 192.168.0.1 1
Address Description State
New0 02:00 0.00:00 ID 974LX02:00
A
B
KeY: = Add data; = Modify data; = Save data; = Cancel changes
TelevisGo Page 7/9
Device naming: Go to Settings Interfaces name (optional) for all devices in the network, you can set the following manually:
• A Long name (Description)• A Short name (Alias, to send TXT messages in future versions)• A Delay in minutes (after which a message is sent, applies to alarms only).
You can also select the resources you want to monitor. noTe 1: for further details, refer to the Manual (section entitled “Installation/Maintenance“)
Data-logging interval: Go to Settings Data archive Control On opening this menu, click “Saved data-logging interval in archive”, then Modify ( ), enter a number
(hours:minutes:seconds) and press Save ( ). The time set is the interval in which data from the selected resources will be logged. noTe 1: This interval does not apply to Statuses, Alarms and Digital Inputs. In these cases, only
changes in the variables themselves are recorded, and not in relation to the interval set. noTe 2: An interval cannot be set while data logging is underway.
Start data-logging: Go to functions Start/Stop from here you can Start/Stop logging data. Depending on whether data logging has started, press:
• Start (when Data logging Status = Suspended)• Stop (when Data logging Status = Underway).
Once data logging has started, you will be able to view the data captured and any alarms that have occurred.
TelevisGo Page 8/9
4. WARnInGS
4.1 ReSPonSIBILITY AnD ReSIDUAL RISKSeliwell Controls srl declines any liability for damage due to:
• Unspecified installation/use and, in particular, in contravention of the safety requirements of established legislation or specified in this document;
• Use on equipment which does not provide adequate protection against electrocution, water and dust in the actual installation conditions;
• Use on equipment in which dangerous components can be accessed without the use of specific tools;• Tampering with and/or modification of the product;• Installation/use on equipment which does not comply with established legislation and standards.
4.2 DISCLAIMeRThis document is the exclusive property of eliwell Controls srl and may not be reproduced or circulated unless expressly authorized by eliwell Controls srl itself. Every care has been taken in preparing this document; however, eliwell Controls srl cannot accept liability for any damage resulting from its use.The same applies to any person or company involved in preparing and editing this document. eliwell Controls srl reserves the right to make changes or improvements at any time without notice.
eliwell Controls Srl
via dell’ Industria, 15 Z. I. Paludi
32010 Pieve d’ Alpago (Bl) - Italy
Telephone +39 (0) 437 986 111
facsimile +39 (0) 437 989 066
Sales:
+39 (0) 437 986 100 (Italy)
+39 (0) 437 986 200 (other countries)
Technical Support:
Technical helpline: +39 (0) 437 986 300
email: [email protected]
www.eliwell.it
9IS54228-1 - Quick Start TelevisGo - 09/11 - EN© Copyright Eliwell Controls s.r.l. 2011 - All rights reserved