+ All Categories
Home > Documents > TENDER DOCUMENTS - ctrtiranchi.co.in · TENDER DOCUMENTS CENTRAL TASAR RESEARCH & TRAINING...

TENDER DOCUMENTS - ctrtiranchi.co.in · TENDER DOCUMENTS CENTRAL TASAR RESEARCH & TRAINING...

Date post: 28-Mar-2020
Category:
Upload: others
View: 11 times
Download: 0 times
Share this document with a friend
24
TENDER DOCUMENTS CENTRAL TASAR RESEARCH & TRAINING INSTITUTE CENTRAL SILK BOARD, MINISTRY OF TEXTILES, GOVT. OF INDIA, NAGRI, RANCHI -835 303(JHARKHAND) Phone Nos. 2775823, 2775630, 2775631(STD CODE-0651) TENDER NOTICE No.CTR&TI/3(53)/XI PLAN/VOL.III/2010-11/Stores Dt.2 nd August’2010 Central Tasar Research & Training Institute, Ranchi invites sealed tender in duplicate for supply of different scientific equipments by 31 st August2010 upto 4.00 P.M.. For details of equipments and its specifications, terms conditions and other information please visit our websites www.ctrtiranchi.co.in or www.silkboard.org . Sd/- Director
Transcript

TENDER DOCUMENTS

CENTRAL TASAR RESEARCH & TRAINING INSTITUTE CENTRAL SILK BOARD, MINISTRY OF TEXTILES,

GOVT. OF INDIA, NAGRI, RANCHI -835 303(JHARKHAND)

Phone Nos. 2775823, 2775630, 2775631(STD CODE-0651)

TENDER NOTICE No.CTR&TI/3(53)/XI PLAN/VOL.III/2010-11/Stores Dt.2nd August’2010 Central Tasar Research & Training Institute, Ranchi invites sealed tender in duplicate for supply of different scientific equipments by 31st August’2010 upto 4.00 P.M.. For details of equipments and its specifications, terms conditions and other information please visit our websites www.ctrtiranchi.co.in or www.silkboard.org. Sd/- Director

Name of the equipments:

Sl. No

Name of equipments Quantity

1 Orbital shaker 2 2 Laminar air flow with all accessories 1 3 High resolution Handycam video camera with still photography

facilities 1

4 Reverse photoperiod equipment (day and Night monitor) 1 5 Portable leaf area meter 1 6 High performance thin layer chromatography (HPTLC) 1 7 Trinocular Research Microscope with phase contrast, fluorescence

application and camera attachments and image processor 1

8 Protein / Haemolymph Lypholyzer 1 9 Automatic nitrogen estimation system 1 10 Electronic analytical top loading balance 2 11 High speed centrifuge / Ultracentrifuge IK to 50K rpm 1 12 Centrifuge, cooling (Table top) 1 13 DNA mixer (rotary) 1 14 Dry bath 1 15 Incubator with shaker 1 16 Shaker (50 to 300 rpm; 6-50OC) 1 17 Extraction unit (2-6 places unit) with accessories 1 18 Vacuum rotary evaporator with bath and Vacuum pump 1 19 Image analyzer 1 20 Sequencing Gel system 1 21 Projection microscope 1 22 Wrap reel & auto sorter 1 23 Seriplance and standard photographs 1 24 Serigraph 1 25 Cohesion tester 1 26 Conditioning oven 1 27 Electronic /IR moisture meter 1 28 Instron strength tester 1 29 Electronic twist meter 1

Sl. No

Name of equipments Quantity

30 Polarized microscope 1 31 Uster evenness 1 32 Uster thick & thin place 1 33 Dynascan 1 34 Crimp tester 1 35 Electronic twist tester 1 36 Burshting strength tester 1 37 Drape testr 1 38 Xenon tester 1 39 Exposure rack 1 40 Laundrometer (automatic) 1 41 Visual cabinet/booth 1 42 Cottage steamer 1 43 Jigger dyeing (lab model) 1 44 Hank dyening machine 1 45 Winch dyeing 1 46 Loom with jacquard 1 47 Power loom for silk 1 48 Clandaring macine 1 49 Mini stenter 1 50 UV-VIS Spectrophotometer 2 51 Flame Photometer 2 52 Electronic balance 2 53 pH meter 2 54 Conductivity bridge 2 55 Single glass distillation (Horizontal) with heating unit 2 56 Furniture for carrying out analysis with acid resistance ceramic top 2

TERMS & CONDITIONS

1. Delivery All scientific equipments enlisted from sl. no. 01 to 49 will be delivered & installed at CTR&TI, Nagri , Ranchi (Jharkhand) except the equipments mentioned from sl. no.50 to 56. These fourteen equipments will be supplied and installed at Regional Tasar Research Station, Central Silk Board, Mantripokhari, IMPHAL (Manipur) and Regional Tasar Research Station,Central Silk Board, JAGDALPUR(Chhattisgarh) at the rate of seven equipments to each station as per following break up: UV-VIS Spectrophotometer- (One Imphal & One Jagdalpur) Flame Photometer-(One Imphal & One Jagdalpur) Electronic balance-( One Imphal & One Jagdalpur) pH meter-(One Imphal & One Jagdalpur) Conductivity bridge-( One Imphal & One Jagdalpur) Single glass distillation (Horizontal) with heating unit-(One Imphal & One Jagdalpur) Furniture for carrying out analysis with acid resistance ceramic top- (One Imphal & One Jagdalpur)

2. Quantity Quantity of the equipments will vary at the discretion of the Director, CTR&TI, Ranchi

3. Submission of tender

Sealed cover tender should be sent to “the Director, Central Tasar Research and Training Institute, Central Silk Board, Ministry of Textiles, Govt. of India, Nagri- 835303, Distt. Ranchi (Jharkhand). The sealed cover duly super scribed on the envelop as RATE QUOTATION FOR (Name of equipments) AND DUE DATE 31st August’2010 FOR ITS RECEIVING. The cost of tender documents is Rs. 200/-. In case of down load the same amount should be remitted along with the tender documents through Bank Draft in favour of “ Director, Central Tasar Research & Training Institute” and payable at Ranchi.

4 Opening of Tender

The tender will be opened on1 1st September’2010 at 11.00 AM at CTR&TI, Nagri, Ranchi. The Proprietor or their authorized representative may attend while opening the tender. In case the Office remain closed on the day of opening of quotations due to holiday/bandh or any unforeseen unavoidable circumstances, the tenders will be opened on the next working day.

5 Cost of equipment

The cost of equipments should be shown separately along with taxes, duties, transportation charges etc. upto Central Tasar Research & Training Institute, Nagri, Ranchi as well as IMPHAL & JAGDALPUR as the case may be, and any other charges to be levied which shall be firm and not variable. In case of foreign equipments, all arrangements have to be made by the firm who will quote the rate for such equipments so that the safe door delivery of the same could be done to CTR&TI, Nagri, Ranchi/ Imphal/Jagdalpur as the case may be. For this all expenditure should be mentioned in detailed & clearly.

6 Document required

Descriptions of the firm including registration/license no., experience, Technical capability, financial capabilities and supply made during last five years in the same line.

7 Validity Validity of quotations should not be less than 90 days from the date of its opening date.

8 EMD 2% of the estimated value of the equipments should be submitted along with rate quotations in the form of Demand Draft/Banker’s cheque/Fixed deposit certificate/Bank Guarantee of any nationalized commercial bank failing which the quotations will not be entertained. The EMD may be rounded off to the nearest 50/- rupees which should be drawn in favour of Director, Central Tasar Research & Training Institute, Ranchi and payable at Ranchi on any Nationalized Bank. The parties those have deposited EMD along with their rate quotations in terms of this Office “TENDER’ dated: 21.06.2010 have been retained at this Office. Such parties need not to deposit EMD along with their rate quotation again. However, in case the EMD value exceeds than the deposited amount of EMD due to the reasons of either quoting higher rate or quoting additional equipments which were not quoted earlier etc., in such circumstances the difference of EMD is to be deposited along with rate quotations to full fill the required norms of total @ 2 % EMD.

9 SMD 5% performance security shall be deposited by the party in the form of demand draft or through Bank Guarantee to whom supply orders will be served. The DD/Bank guarantee etc will be in the same manner as mentioned above at sl. (8).

10 Warranty Warranty should be clearly mentioned in the rate quotations. Maintenance terms of equipments may also be mentioned.

11 Supply of Equipments.

Supply of the equipments will be made within one month from the date of issue of supply orders along with performance security etc. to the respective destinations. In case of parties those will quote foreign equipments and required to be imported. It will be the sole responsibilities of such parties to make all necessary arrangements for its custom clearance at the landing air port without demurrage charges and its safe transportation upto this Institute/destination place by them (Tender quoting agency/firm) only. No any clearing agent will be appointed by this Office separately for custom clearance.

12 Installation and demonstration

The purchase of equipments will be installed and demonstrated & shown in working conditions at this Office premises as well as Imphal & Jagdalpur by the representatives/Engineers of the company free of cost. In case the equipments do not perform smoothly or having any defect, the same shall be taken back by the party at his own cost and arrangements. This office will not have any liability for the same.

13 Belated supply

In case the party supply the equipments belatedly or fails to supply the equipments, the EMD deposited by the party will be forfeited apart from canceling the supply orders.

14 Payment On successful supply of the equipments/installation, the bill in duplicate may be submitted to this Office which will be paid. For imported equipments the payment will be settled through opening of L/C. In such case all L/C charges should be clearly mentioned. In case of payment demanded by the firm through wire transfer, the Bank Guarantee of equal amount will have to be submitted to this Office.

NOTE: Earlier tender dated: 21st June’2010 has been cancelled due to administrative reasons.

Sd/- Director

15 Taxes and duties

(1) Up to date sale tax paid certificate of the concerned state along with TIN/TAN/PAN nos. should be incorporated with the tender documents. Otherwise the taxes would be deducted while settling the bill at this Office or the party may assess and deposit the taxes at his won level. Declarations should be given by the party along with the rate quotations. (2) Latest commercial tax clearance certificate should be enclosed with tender.

16 submission of quota tions.

The sealed cover rate quotations may be sent by post or directly submit in person. Unsealed cover or quotation submitted by FAX/E-MAIL etc. will not be accepted. The Director, CTR&TI, Nagri, Ranchi reserves the right to reject any or all the quotations at any time without assigning any reasons thereof.

17 Change of orders

The Director, CTR&TI, Nagri, Ranchi reserves the right to modify /cancel the supply orders or the quantity of equipments may be raised/reduced.

18 Settlement of disputes

Any disputes arisen between the CTR&TI, Nagri and the supplier/party will be resolved amicably keeping in view of the terms and conditions of this “tender” and discretions of the Director, CTR&TI, Nagri. Failing which the decisions of Judiciary of Ranchi jurisdictions will be final.

CENTRAL TASAR RESEARCH AND TRAINING INSTITUTE RANCHI

LIST OF EQUIPMENTS

Sl. No

Name of the equipment

Specifications

1 Orbital shaker Motion – orbital Speed – 30 to 250 rpm Speed controller – digital Platform size – 410mm x 410mm Temperature – above ambient to 600C Accuracy - ± 0.50C Body – MS with powder coated Circulation – Forced with centrifugal force Inner chamber – Approximately 430 x 450 x 550 mm Input voltage – 230v 50 hz AC power supply Should accommodate - 50ml, 100ml, 250ml and 500ml flasks

2 Laminar air

flow with all accessories

1. Flow: Vertical 2. Particle Retention: 0.3 Micron & above. 3. Retention Efficiency: 99.97% 4. Velocity: 90FPM 5. Motor: ¼ HP, 1440 RPM, 220V 6. Impeller: Aluminium Centralfugal type. 7. Noise level: 65dB (A) +/- 5%. Accessories: 1. Static Pressure Manometer. 2. U.V. Germicidal Tube 3. Transparent Front Door and Sides 4. Cock for gas, air or vacuum line.

3 High resolution Handycam video camera with still photography facilities

Mega Pixels-14, LCD-3.0, No. of shots-290, optical zoom- 20x, Digital zoom-40x Memory card and image transferring software with chargeable battery.

4 Reverse photoperiod equipment (day and Night monitor)

1.With remote relays [BSR (USA) Ltd, Cat. No. AM 601/611 =Sears Cat. No. 34K5459] intended for fixed voltage loads rather than the variable voltage models intended for incandescent lamps and featuring dimming control.

2.Similar programmable microprocessor/ timers and the relays are generally available. 3.The programmable controller can control at least eight different remote relays. 4.Two solenoids are required per box and there are eight channels available for programming in the

microprocessor. 5.Each channel can be programmed for two on-off cycles per day so it would be possible to program a light

break as short as 1 min during a dark period. 6. Light-tight boxes with hinged, counterbalanced lids constructed from plywood and painted with several coats of white epoxy paint. 7.Magnetic cabinet door catches

5 Portable leaf area meter

SPECIFICATION: Measurements: Leaf Area, Length, Perimeter, Shape Factor and Aspect Ratio Measuring Thickness: 25 mm max Measuring Width: 150 mm max Measuring Length: 32 m max Accuracy: + 1% for sample > 10 cm2 Interface: RS-232C Serial Interface Memory Size: 64 KB, 15000 readings Display: LCD, 16 Character x 2 lines Scanning Speed: 400 mm/sec. Battery: Rechargeable 7.2 V Operating Temperature: 0-50oC Weight: Approx 1 kg. Includes: 7.2 V rechargeable battery, AC Adapter/Battery Charger, RS-232 Communication Cable, Communication Software, Operating Manual & Carrying Case.

6 High performance thin layer chromatography (HPTLC)

A. HPTLC SYSTEM MANAGER: software to control all instrumental steps including application, development, scanning and photodocumentation.

B. SEMI AUTOMATIC SPOT / BAND APPLICATOR: Sample spot / band applicator: Quantitative

analysis, micro-preparative, in-situ and superimpose, 100 ul & 500 ul syringes. C. CHROMATOGRAM DEVELOPMENT CHAMBERS: Glass, internal volume chambers, maximum 5-

15 ml mobile phase / run, Size chambers for 20 x 20, 20 x 10,10 x 10, 10 x 5 cm plates. D. PHOTO RECORDING UV CABINET: Dual wavelength, UV Cabinet with a digital camera mount.

Enable to inspection and photodocumentation, Flickerless illumination. E. DIP TANK WITH LID FOR DERIVATIZATION F. MULTIPURPOSE CHAMBER FOR METHOD DEVELOPMENT: Multipurpose Chamber for method

development Six mobile phases on one plate, G. TLC SCANNER WITH DATA EVALUTION: Computer controlled Scanner / Densitometer, Automatic

quantitative measurement by absorbance & fluorescence. Scan speed 100 mm / sec @ 25 μm resolution, Wavelength range 190-800 nm. Data sampling rate – 4000 / sec. Spectrum scan speed 100 nm / sec. Max 999 spectra / plate. D2, Hg, W lamps + self diagnostic + Service dialog + Universal filter for fluorescence, H. Digital Camera: 12 bit, high resolution industrial camera.

7 Trinocular Research Microscope with phase contrast, fluorescence application and camera attachments and image processor

Microscope should have resolving nose piece, anti-fungus plan achromatic infinity corrected objectives 4x,10x,40x (spring0 & 100 x (oil, spring), paired eyepieces wide field 10x(field No. 200, with a trinocular head 30° inclined seidentopf, abbe condenser with aperture iris diaphragm (N. A. 1.25). With LED Illuminator and battery backup attachment. T hermo Cole packing & Dust Cover . Should have Fluorescent attachment of Trinocular Microscope Micro LED- Florescent Attachment for Blue & Green excitation High efficiency illuminator for transmitted light fluorescence with power supply, clamps directly on microscope stand allowing transmitted light also bright field, high efficiency fluorescence condenser, blue LED cassette with excitation wavelength 450nm, long pass 575 emission filter , Green LED cassette with excitation wavelength 535 nm, long pass 575 emission filter enhanced AI + SiO2 mirror,. Adapter, 45°C slider with mirror, 45° slider with blue filter, Ring spacer Magnus “Easy”, Fluorescence condenser, Blue and Green LED cassette 1, 3 positions filter slider with o-rings, 100-240 v power converter, 1-channel fixed control unit 1, Power cord EU 1 & Micro LED transport box. Should have Digital SLR Camera System for Trinocular Microscope (fitted on halogen or LED illuminator Microscope). Olympus or Digital SLR camera above 12 mega pixel resolution with rechargeable batteries along with charger, SLR Microscope Adapter and with 2 GB memory card with software. Standard zoom lens (1) and carry bag.

Entomology: 1. Standard set complete with 6V20W halogen light illuminator with Ant-Fungus Achromatic

objectives iNEA 4x, 10x, 40x(spring), & 100x oil & Spring), Paired Eyepieces wide field iCWHK 10x (Field No. 18) & with a trinocular head in thermocole Packing & dust cover.

2. Digital camera system complete with any renowned (Sony, Nikon etc.) available brand digital camera (above 7 mega pixels resolution with rechargeable batteries along with charger, Magnus Microscope Adaptor wi th memory card and image transferring software with USB case.

8 Protein /

Haemolymph Lypholyzer

2. Haemolymph Lypholizer or Vacuum Concentrator with refrigerated Trap: Specifications: Operated on 220V/50 Hz.

Vacuum concentrator designed for high speed and maximum recovery of DNA, RNA, Protein, Peptides, Amino Acids, Hormones, Enzymes etc capable of freeze drying also.

One touch microprocessor control for automatic operation of cooling, vacuum and drying process. High vacuum rotary vane pump for faster drying and freeze drying application fitted with anti blow back valve

and air ballast. Capacity 100 LPM. Ultimate vac.0015 mbar Various rotors from 1.5 ml up to 50ml. Thick acrylic lid with safety lock Rotor speed 1800 rpm. Maintenance free induction motor, magnetically driven rotor. Concentrator capacity: up

to 72 nos. tubes depending on the size of the tube. Micro processor controlled digital display of temperature, pressure, overheat protection, temp. limiting function etc. Lowest temperature -95°C to trap water and most of the alcohol solvent. Standard rotor included 72 x 1.5/2 ml. Vacuum pump (100 LPM). Ultimate vacuum pressure 1.5x10-3 motor with gas ballast and anti blow back valve

6 port T-type manifold (valve, adaptor, cap)-6 sets (Freeze drying manifold with fittings and connecting for simultaneous operation of Speed vac and Lyophilizer.Rotor for 6 nos. x 50 ml tubes

9 Automatic nitrogen estimation system

Fully Auto Run completely Programmable Autoseq Microproessor based Distillation System with in-built software & Auto Titrator Connectivity Features Fully Automatic sequencing with auto Intelligent run of 8 programmable steps which include Automatic Boric Acid Addition, Automatic Dilution, Automatic KMNO4 Addition for Available Nitrogen, Automatic Alkali Addition, Automatic Reaction Delay time, Automatic Steam Processing, Automatic Residue Delay time & Automatic Residue Removal. 50 Predefinable User Storage Auto Sequence Programmes, Distillation Capacity: 15-20 samples/hr, Nitrogen Recovery >99.5%, High grade Stainless steel non corrosive steam Generator, Fully Automatic water level monitoring with centrifugal refilling pump & Perilstatic pump for reagents addition. RS 232 interface for connectivity to printer & PC, Auto door open indication, Auto tube insert error indication. Adjustable steam power: 35-100%, Auto online water saving mechanism. Auto reagent level indicators with alarm. Standard RS 232 connectiivity kit with USB port. Standard Auto Titrator Connectivity kit, Standard operating software feature, Built in safety features, Electrical Requirement-220V/50Hz.

10 Electronic analytical top loading balance

Capacity : 8200g

Readability : 0.1g

Tare range (Substractive): 0-8200g

Tare Button: 2

Repatibility: < = ± 0.2g

Response time: < - 1 second

Display: Backlite (Blue)

Pan : 190 x 204 mm

Housing: (W x D x H): 213 x 342 x 90 mm

Net weight: Approx. 3.2 kg

Accessories:

Data printer with connection cable, adjustable for CE stamp approval, with GLP and GMP function for all

balances and moisture analyzer, external rechargeable battery.

Electronic

analytical top loading balance

Microprocessor based with full tare facilities: Technology - Monobloc Maximum Capacity - 220gm Readability - 0.001g/1mg Repeatability - 0.001g Linearity - 0.002g Weighing Pan - 120mm Dimension - 290x184x188mm Battery Backup - Internal Diagnostic feature e.g keypad and repeatability test Over load protection Calibration Internal RS232 Interface

11 High speed centrifuge / Ultracentrifuge IK to 50K rpm

Operated on 230V/50 Hz, AC

FEATURES:

• Drive unit should be warranted for 5 Years • Operated on 230V/50 Hz, A C • Should have high efficiency vacuum dr iving unit, acceleration to the maximum rotation speed

of 150000 rpm within 100sec • Non-contact imbalance protection, samples needs only to be balanced to within 5 ml by

eyeview. • Should have self locking rotor. • Dual C.P.U over speed protection mechanism • Maximum speed 1,50,000 r pm • Maximum RCF 1050000 xg • Adjustable speed should be 5000 to 150000 rpm • Timer should be 1 min to 99 hrs 59 min with HOLD and Real Time Control (RTC function) • Vacuum system : Oil Rotary Vacuum Pump and oil diffusion pump • Rotor temperature control range should be 0 to 40 degree C • Rotor cooling method should be Thermo Module cooling system (HFC Free) • Adjustable LCD display of all parameter • Rotor setting method should be simple quick setting ( no special tools required) • Heat dissipation into room 0.6 kw • Operational noise level should be 47 dBA • Should be certified by IEC 61010-2-020, EN 61326 • Centrifuge should be completed with following rotors 1) Fixed Angle rotor 10 x 1 ml ( tube capacity 2 ml)

Max Speed : 140000 rpm Max RCF : 1050000 xg

12 Centrifuge, cooling (Table top)

The centrifuge should be Microprocessor controlled with Large LCD display for Speed, RCF, Running time & temperature. Speed range should be from 200 -15000 rpm with 10 rpm increments. Pre-selection of running time from 10 sec to 99 h 59 mi n. Minimum 10 accélération / de-acceleration. Built-in Pre cooling programe. Temperature range : -20°C to +40°C in steps of 1°C increment Audible signal at end of each run Storage up to 99 programme runs & recall. Noise level < 56 dBA at 20000 xg Max Speed should be 15000 rpm Max RCF should be 21380 x g The system shoul d confirm CE-Requirements and manufactured according to IEC 1010 & 1010-2 standard. 1) 44 X 1.5 ml / 2.0 ml tubes with RCF : 17625 xg ,

13 DNA mixer

(rotary) Speed – 5 to 60 rpm Platform – Magnetic base Motion – Circular RPM indicator – Digital/Analogue Platform size – 300mm x 220mm Input voltage – 230v 50 hz AC power supply Capacity – Should hold 1.5ml and 15ml tubes

14 Dry bath Temperature control – digital

Temperature range –ambient to 1000C Accuracy - ± 0.50C Block size – Approximately 9.5 x 7.5 x 5 cm Block capacity – 0.5ml, 0.2ml, 1.5 ml Size - Approximately 16 x 21 x 13 cm Input voltage – 230v 50 hz AC power supply

15 Incubator with shaker

Features:

• Fully microprocessor controlled & digital display of all parameters – speed, temperature, time & auto tuning / calibration

• Safety device should be CLS ( Custom logical safe) control system class II • 9 step temperature programmed control, over temperature limiter & door opening alarm. • Bright VFD display & capaci tive touch screen button. • Digital timer 1 min 999 hrs 59 min f or shaking • It should soft start features eliminates splashing of samples • Adjustable fan speed wi thin 3 steps • Shaking speed 10 rpm to 300 rpm, with brushless DC motor for long maintenance free

operation • Should have gas spring door/ transparent lid guard against sudden closures & viewing • Universal platform for multi-use • Built-in RS 232 interface • The system shoul d have some International Certificates like ISO 9001:2000, CE & UL for

safety.

16 Shaker Operated on 230V/50 Hz Controller : Digital P.I.D. auto tuning Microprocessor Controlled.

o Precise rpm control is suitable to user’s experimental purpose. o CLS(Custom Logical Safe) control system o Self diagnostics function makes it easy to find error and correct them. o Opto – electric feedback control system calculates motor output corresponding

weight load o keeps precise rpm control in all cases.ISO 9001:2000, CE & UL Cer tified. o Brushless DC motor supplies long durability and stable performance of shaking

platform. Type : Orbital(forward, backward, pause and stop in same position), Reciprocating : option.

Working range : 10 to 500 rpm. Stroke length : 20, 30, 40 mm available (30mm standard) Accuracy : +/- 1 at 150 rpm. Timer Run time (999 hrs 59 mint .), pause (max. 99 min. Min 1 min) Forward and backward (Max. : 9 min 50 sec, Min: 10 sec) Drive system : Brushless D.C. motor with feedback cont rol. RPM Indicator : Digital . System shal l be completed with universal platform with 6 x 250 ml, flasks. Unbalanced l oad sensor limits shaker motion when excess vibration is detected; visual /audible alarm signal

17 Extraction unit (2-6 places unit) with accessories

Main power: 230 V Frequency:50 Hz Power consumption:1200 Extractor volume:180 ml Beaker volume:130 Dimensions:275 x 456 x 776 (L x W x H) Accessories 1. Adapter for cooling media input 2.Beaker holder 3.Condenser 4.Condenser cover 5.Distillation Chiller cooling to a fixed temperature of 10°C, 230V 50/60 Hz 6.Holder for glass sample tubes, PTFE, microwavable 7.Pack of paper thimbles 33 x 94mm 8.Pair of glass tongs 9.Pliers for glass sample tube with frit 10.Recirculating Chiller 11.Set of glass sample tubes with frit 12.Set of holders for glass sample tubes with frit 13.Set of thimble holders, 33 x 94mm 14.Z-seal-system: Seal holder, Set of z-seals, Set of seals 15.Sample holder, 16.Set of seals for extraction chamber 17.Holder ring

18 Vacuum rotary evaporator with bath and Vacuum pump

1. 6 types of flasks ranging from 50 to 3000ml 2. Speed control and R.P.M. displayed in digital 3. Digital water bath covers ambient temperature up to 180OC. 4. If water level at heating bath goes down, power will be cut off automatically by sensor. 5. Speed control: 20 � 280 R.P.M. 6. Vertical condenser 7. Standard distillation. 8. Continuous supply device for large capacity 9. Central connection 10. Dimensions (WxDxH) : 320x580x720mm 11. Power source: AC 220v 50/60Hz2.5A 12. Heating Bath Power Wattage: 1,000W 4.5A. 13. Weight:17kg

19 Image analyzer Specification for Image Analysis Software

Multi-Fluorescence Mode (Define up to 5 different color filters, Capture monochrome images and have them colored automatically, Use the image merging to generate multi fluorescence images, Black balance to avoid auto-fluorescence). - Measurement tools & Annotation - in live & captured image (Calibrate your camera, Display calibration bar, Measurements: Line, Circle, Ellipse, Angle, Rectangle, Polygon, Freeform, Storage in separate layer (.xml-file), export to analysis software possible). - Gallery (The captured images can be displayed in an image gallery, Select, delete, rename or replace the images according to your needs, Complete image sessions can be loaded into gallery). - Multi-Camera Operation (Connect up to 5 cameras to one computer, Conveniently choose the desired camera at program start or switch between different cameras within the software).

Extended Image Display Functionality (continuous AutoExposure, Rotate/Mirror, ROI function in full pixel resolution, adjust RGB values in live image, white and black balance (Fluorescence), Live gamma, contrast, brightness, saturat ion adjustments). - Shading correction (Flatfield correction (homogeneous light) and background subtraction (reduce dark current) options available for both the live and the captured image). - Multi-language support: German, English, French, Spanish, Italian, Japanese, Chinese. - Free-Software-Upgrade: Registered users may download the latest software and its new features

for free! This upgrade possibi lity covers the whole lifetime of your product. - Storage as movie file.

20 Sequencing Gel system

Specifications: Buffer volume 500mL Buffer disposal Internal drain system and removable lower buffer tray Gel size (W x H x D) 29 x 22 x 68 c m

21 Projection microscope

For fibre fineness tester 200mm graduated screen, built-in Fresnel lens, loop and arrow arrangement and coaxial mechanical stage of size 135X120mm. Quadruple revolving nosepiece. Provide magnification from 125 xs to 1000x. Halogen lamp 12 volts, 100 watts, workable on 220V/110V AC. Objectives : 5x, 10x, 20x, 40x.

22 Wrap reel & auto sorter

For Size test, Linear density Reels upto 10 cops/yarn skeins having 1 m Reelcircumference for evaluating all count system. Number of revolutions can be pre-selected from 1 to 200 by the operator through keyboard with LED display under microprocessor control with digital counter; single phase 220 V.

23 Seriplance and standard photographs

For Evenness, Neatness, Cleanness Set of black boards’ carrier & standard photos included for yarn appearance evalution

24 Serigraph For Tenacity; Elongation 25 Cohesion tester For cohesion/ adhesive test of filaments

The cohesion tester consists of a frame with a set of 10 hooks on each side of the frame. 26 Conditioning

oven 27 Electronic /IR

moisture meter

For moisture content & moisture regain of textile fibres/filaments having observing window and light with micro-adjusting level or digital temperature controller, 220 volt, upto 220 o C ; 20-30 ltrs; Lab model only For moisture content & moisture regain of textile fibres/filaments having observing window and light with micro-adjusting level or digital temperature controller, 220 volt, upto 220 o C ; 20-30 ltrs; Lab model only.

28 Instron strength tester

For single yarn strength/tenacity & elongation of Single, twisted thread , Fabric, Loop/Knot strength Lea trength, Single fibre strength test; load cp CITY 100-200 kg; jaw separation upto 600mm; traverse speed 50- 500 mm per minute.

29 Electronic twist meter

For Twist in yarn digital Lab. model

30 Polarized microscope

Cross sectional view of filaments; Yarn diameter; Microscopic test of fibres

31 Uster evenness tester

Evenness test of yarn. Evenness of silk yarn for suitable measurement range and testing speed

32 Uster Thick& thin place suitable spectrogram range for silk yarn 33 Dynascan Thread density in fabrics. [Lab model] 34 Crimp tester For crimp in yarns and bulkiness in fabrics; capacity upto 2 feet, Crimp Tension range of 0-35 Gms. Additional

weights provided for extending the range to 0-175 Gms (dead weight) 35 Electronic twist

tester Warp/wept twist Direct TPI/TPM results in digital display microcomputer based operation ;Adjustable gauge length upto 20 inches; single phase 220 V @ 50 Hz;setting range -10 to 100 mm and tensioning range 1 to 99gm.

36 Burshting strength tester

For Bursting strength of fabrics Aesthetic table design model suits laboratory; Dual gauge system upto 28kg/cm2 ;single phase 220 V @ 50 Hz; 200 watts

37 Drape tester For Drape properties of fabrics Having halogen light source along with template, liquor ammonia, steel bowl and ammonia paper

38 Xenon tester For light fastness of dyed samples textile lab model 39 Exposure rack Supper Daylight for identification and contrast of colour of products for quality having upto 20-30 kg weight; (

lights D65, F, UV etc.) 70x50x70 cm dimension or Lab. model 40 Laundrometer

(automatic) For Wash fastness Rotating range 40-50 RPM; temperature control/ adjust from 40o C -85o C; timer 20,30,45 60 minutes; steel balls , 220 v; 110 x 70 x 134 cm or 550 ml x 8 jars; single phase 220 V, 4000 watts Lab. model

41 Visual cabinet/booth

Colour assessment Microprocessor controlled operation along with switch panel & LCD display having 2 feet capacity; single phase 220 V;200 watts; standard light source ( artificial light, tungsten filament, UV black light, fluorescent etc.

42 Cottage steamer Twist & print fixation/steaming having Laboratory Steamer for fixation of prints under high temperature high pressure conditions. Ideal for saturated steaming upto temperature of 130°C. Samples are hooked on star frame and placed in an inner chamber. Maximum sample size 200 mm x 2 mtrs. Electrical heating for steam generation. Nozzle provided for external steam supply. Facility for steam super heating at atmospheric pressure available. Fabricated out of 10 mm thick MS plate of IS quality

43 Jigger dyeing (lab model)

Fabric sample dyeing practical Tank Size - 66 inches b. Roller Size – 60 inches c. Roller Diameter – 5 inches d. Roller and tank of the machine should be fabricated with 316 grade stainless steel e. Stand has to be fabricated in mild steel f. Motor - 2 H.P g. Speed - 300-400 meter per minute

44 Hank dyening

machine Yarn (hank) dyeing [Lab model]

45 Winch dyeing Soft fabric dyeing Capacity 5-10 kgs Winch Dyeing Machine Machine size 1150mm x 700mm x 1400mm Material ( Sheet) S.S.304 / S.S.316 Rollers Shafts S.S.304 / S.S.316 Roller Square pipes S.S.304 / S.S.316 Direct steam coil S.S.304 / S.S.316 Motor bed S.S.304 / S.S.316 Pulley Stand S.S.304 / S.S.316 legs S.S.304 / S.S.316 Motor 1 H.P. Dyes tank should be with steam coil Attachment of water level indicator Attachment of Temperature sensor with digital display, SS out let valve(conical type) Control panel, view glass

46 Loom with jacquard

Weaving training/ practical 1. Electronic Jacquard should be suitable for silk handlooms 2. Electronic Jacquard can be able to control up to 1200 hooks. 3. All electronics should be designed for continuous operation and to work in hostile conditions. 4. Since the controller is driven by the PC, software can be modified and custom made. 5. One IBM PC can control more than 6 Electronic Jacquard controllers.

6. PC being the heart of the Electronic Jacquard, a host of diagnostic software and reliability comes as a package deal. 7. All the Electronic Jacquard controller scan be controlled from the central control station with remote administration. 8. All designs can be kept at the control station archive and free from tampering. Last minute changes can be done to designs Sitting at the control room. 9. All designs from the design station can be downloaded to the controller station via network so that no data loss or media corruption problem arises unlike other systems, which use floppy discs for transferring designs to the Electronic Jacquard controller units. 10. Respective costs for software and hardware should be mentioned separately.

47 Power loom for silk

Weaving training/ practical Suitable for denier in the range of 20 denier to 200 denier.

48 Clandaring machine

For Finishing of silk fabric Additional pressure & pressure release pattern Calender roller material: Upper & Lower rollers > Rubber. Middle roller > Copper. Effective width: 1600mm. From Central distance: 2100mm. (L x W x H) >1800x 2400x 2300m Number of bowls: Three, It is to be steam heated. Rate may please be quoted for the electrically heated machine also. fabric Width: 1000-1500 mm. Driving system: Variable speed drive motor Cloth feed rollers should be provided. Suitable to finish silk fabrics.

49 Mini stenter Drying of samples For drying, curing and thermo fixation of samples. Working width 450mm, 600mm. Speed control for variable dwell time of 30 seconds to 5 minutes. Internal heater provided for pre heating. Electrical heating for temperature upto 250°C. Heating zone length: 1700mm. Adjustable air flow to avoid migration Can be used either for small sizes of samples or for continuous fabric length. Can be synchronized with Laboratory Vertical Padding Mangle for continuous padding, drying and curing/setting process.

* Concern with CSTRI, CSB, Bangalore and all above mentioned equipments should be supplied along with spares; User’s guide, applicable standards, Warranty certificate and Test certificate etc.and stallation/calibration.

For RTRS, Imphal and Jagdalpur

Sl. No

Name of the equipment

50 UV-VIS Spectrophotometer Digital Spectrophotometer (UV-VIS) – 2 nos.

Optics: Double Beam Optics Operating System: Microcontroller in 2203 (Through PC in 2202/2201) Wavelength Range: 200 - 1100 nm (190-1000nm in 2201) Spectral Bandwidth: 2 nm (0.5 to 6.0nm variable in 2201) Display: LCD in 2203 (PC Monitor 2202 & 2201) Operating Mode: Single Multi-Wavelength, Scan & Time Scan Measuring Modes: %T, ABS, Concentration & K Factor ABS Range: + 2.5 Abs Detector: Dual Si-Photo diode (Photomultiplier in 2201) Filter / Dark SettingI Automatic, through Software

51 Flame Photometer Digital flame photometer – 2 nos. Sensitivity (FS)

• Sodum (Na) : 2 ppm • Potassium (K): 1 ppm • Lithium (Li) : 7 ppm • Calcium (Ca): 2 ppm

Accuracy : +- 2% of FSD Display : 2.1/2 Digit LED Minimum

Sl. No

Name of the equipment

Sample Volume : 3.5 ml Aspiration Time : 30 Sec. (approx.) Air Pressure : 0.3 to 0.6 Kg/cm2 Power : 230V, +- 10%, 50Hz, 10 VA (approx.) Dimension Main Unit : 725 (W) x 235 (D) x 270 (H) mm Weight Main Unit : 4.5 Kg. (Approx.) Accessories: Instruction Manual, Filters , Gas and Air Tube

52 Electronic balance

Analytical Balance ( Electronic) – 2 nos. Capacity/ Resolution: 300gm/0.01g Precision : ±0.01 Electronic Taring Range: 0 to 300g Pan Diameter : 100mm Wind Draft Shield: Optional

53 pH meter

Digital pH meter – 2 nos. pH Range: 0 to 14 pH, Millivolt Range: 0 to 1999 mv Slope correction: 80% to 105%, Resolution:0.01pH; 1 mv Repeatability: ±0.01pH ±1 digit, ±1mv±1 digit Standardization Range: ±2 pH approx, Temperature compensation: 0 to 100°C (manual) Display: 4 digit LED with automatic polarity and decimal point mode annunciation by LED lamps, Power:230 v±10%, 50 Hz Accessories: A pair of electrodes (glass and calomel) with stand / clamp and an instruction manual.

Sl. No

Name of the equipment

54 Conductivity bridge Conductivity meter – 2 nos.

Display: 3 1/2 Digit LED Range: 0-200 µS 0-2,0-20,0-200 & 0-1000mS Temperature Compensation: Manual 0-50oC (Automatic facility – S-941) Cell Constant Adjustment: Adjustable Conductivity Cell: Platinum DIP Type RESOLUTION: 0.1µS Accuracy: +1% FS +1 Digit Power: 230v + 10% ac, 50 Hz Dimensions: 275 x 175 x 76 mm Weight: 2 kg. (Approx.) Accessories: Conductivity Cell, Operation Manual, Dust Cover, clamp stand, temperature probe

55 Single glass distillation

(Horizontal) with heating unit

56 Furniture for carrying out analysis with acid resistance ceramic top


Recommended