+ All Categories
Home > Documents > TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael...

TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael...

Date post: 25-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
6
Transcript
Page 1: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com
Page 2: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com

D

D

D

D

D

D

D

D

36.00'

45.00'

50.00'

A

V

E

S

O

U

T

H

(

H

W

Y

6

4

1

)

TE

NN

ES

SE

E A

VE

N

OR

TH

(H

WY

641)

(U

.S

. 4

1

2

) T

.N

. 2

0

FARMERS BANK

TENNESSEE VALLEY FORD, INC.

EXISTING R.O.W.

FARMERS BANK

20LPLM-F3-009

BEGIN PROJECT NO.

TAP-2000(17)

STA:0+00.00

(U.S. 412, TN-20)

N 486036.5844 E 1336664.9427

2

16

17

REVISIONS

CONSULTANT

TLM

ASS

OC

IATE

S, IN

C.

ARC

HIT

ECTS

+ E

NG

INEE

RS

731.

988.

9840

(pho

ne) -

731

.988

.995

9 (fa

x)11

7 Ea

st L

aFay

ette

Stre

et

Jack

son,

Tenn

esse

e 38

301

ww

w.tl

mae

.com

DESC

RIPT

ION

NO

.DA

TEBY

May 6, 2019

J5764

PARS

ON

S (S

R-20

)DO

WN

TOW

N E

NHA

NC

EMEN

TS

CIT

Y O

F PA

RSO

NS

for

TYPE YEARPROJECT NO.

SHEET

NO.

COORDINATES ARE NAD/83(1995),

ARE DATUM ADJUSTED BY THE

FACTOR OF 1.00007 AND TIED TO

THE TGRN. ALL ELEVATIONS ARE

REFERENCED TO THE NAVD 1988.

#1-ALL UNDERGROUND CONDUIT SHALL BE A MINIMUM OF 1 INCH.

ELECTRICAL NOTES:

#2-ALL CONDUIT SHALL BE INSTALLED BY DIRECTIONAL BORING AT ROADWAY AND DRIVEWAY

CROSSINGS WHERE PAVEMENT OR CONCRETE IS NOT BEING REPLACED.

#3-ALL STREET LIGHTING CIRCUITS TO BE ROUTED THROUGH LIGHTING CONTACTORS AND

CONTROLLED BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND

TIMER OFF OPERATION.

#4-ALL POLE RECEPTACLE CIRCUITS TO BE ROUTED THROUGH CONTACTORS AND CONTROLLED

BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER OFF

OPERATION.

ELEC

TRIC

AL

SITE

PLA

N

E1.1

E1

.1

MA

TC

HL

IN

E S

TA

:4

+2

5.0

0 S

EE

S

HE

ET

E

1.2

#5-EACH POLE RECEPTACLE NOT TO EXCEED 180 WATTS AND SHALL BE EITHER A WEATHER

RESISTANT GFCI RECEPTACLE OR CONNECTED TO GFCI CIRCUIT BREAKER PROTECTED

BRANCH CIRCUIT.

#6-POLE MOUNTED RECEPTACLES TO HAVE HEAVY DUTY CAST ALUMINUM "WHILE IN USE"

COVER PAINTED TO MATCH POLE FINISH.

#7-CONDUIT ROUTING AS SHOWN ON LAYOUT IS DIAGRAMMATIC AND TO BE USED AS A

GUIDE ONLY. COORDINATE INSTALLATIONS WITH FIELD CONDITIONS AND EXISTING

UNDERGROUND UTILITIES.

Pars

ons,

Tenn

esse

e

PROPOSED POLE LIGHT

TYPE "P" WITH INTEGRAL

RECEPTACLE (TYP.)

1 1/4"C

4-#6

3-#10

CKTS A-10,12,A-14 & A-16

Horz. Scale: 1"=

0

20

P

(L) A-9,11

(R) A-13

P

(L) A-10,12

(R) A-16

CONCRETE COMPOSITE

PULLBOX (TYP.)

1"C

EMPTY W/ PULLWIRE

P

(L) A-10,12

(R) A-16

P

(L) A-10,12

(R) A-16

P

(L) A-10,12

(R) A-16

P

(L) A-10,12

(R) A-14

P

(L) A-10,12

(R) A-14

P

(L) A-9,11

(R) A-15

P

(L) A-9,11

(R) A-15

P

(L) A-9,11

(R) A-15

P

(L) A-9,11

(R) A-15

P

(L) A-9,11

(R) A-15

1"C

EMPTY W/ PULLWIRE

1 1/4"C

4-#6

3-#10

CKTS A-9,11,A-13 & A-15

1"C

EMPTY W/ PULLWIRE

PHA

SE V

1"C

2-#6

1-#10

CKT A-23

2020CONST TAP-2000(17)

E1.1

MICHAEL MCCORMICK, P.E.ELECTRICAL ENGINEER

COMMERCIALINDUSTRIALRELIGIOUS

[email protected]

05/06/19

#8-SEE POLE BASE DETAIL ON SHEET NO. E1.5.

1"C

2-#6

3-#10

CKTS A-9,11 & A-15

CONNECT TO EXISTING TRAFFIC SIGNAL

CONTROLLER. COORDINATE CONNECTION

AND POWER OUTAGE WITH OWNER.

1"C

2-#6

1-#10

CKT A-23

1"C

2-#6

3-#10

CKTS A-10,12 & A-16

1"C

2-#6

3-#10

CKTS A-9,11 & A-15

ADD

END

UM

#1

12/5/2020

AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
80
AutoCAD SHX Text
MAGNETIC
Page 3: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com

X

X

X

X

X

33.00'

31.00'

ALESHA VANDIVER

GRAVES PROPERTIES

D.C

. PR

OPER

TIES

CHARLES E. PHILPOTT

EXISTING R.O.W.

EXISTING R.O.W.

EXISTING R.O.W.

PHILIP BREAZEALE

AND WIFE SHEARON

BRAZEALE

GORDON MIKE FERGUSON

& JAMES G. FERGUSON

GE

OR

GIA

A

VE

N

4

5

12

13

14

15

(U

.S. 412) T

.N

. 20

#1-ALL UNDERGROUND CONDUIT SHALL BE A MINIMUM OF 1 INCH.

ELECTRICAL NOTES:

#2-ALL CONDUIT SHALL BE INSTALLED BY DIRECTIONAL BORING AT ROADWAY AND DRIVEWAY

CROSSINGS WHERE PAVEMENT OR CONCRETE IS NOT BEING REPLACED.

#3-ALL STREET LIGHTING CIRCUITS TO BE ROUTED THROUGH LIGHTING CONTACTORS AND

CONTROLLED BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND

TIMER OFF OPERATION.

#4-ALL POLE RECEPTACLE CIRCUITS TO BE ROUTED THROUGH CONTACTORS AND CONTROLLED

BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER OFF

OPERATION.

E1

.2

MA

TC

HL

IN

E S

TA

:4

+2

5.0

0 S

EE

S

HE

ET

E

1.1

#5-EACH POLE RECEPTACLE NOT TO EXCEED 180 WATTS AND SHALL BE EITHER A WEATHER

RESISTANT GFCI RECEPTACLE OR CONNECTED TO GFCI CIRCUIT BREAKER PROTECTED

BRANCH CIRCUIT.

#6-POLE MOUNTED RECEPTACLES TO HAVE HEAVY DUTY CAST ALUMINUM "WHILE IN USE"

COVER PAINTED TO MATCH POLE FINISH.

#7-CONDUIT ROUTING AS SHOWN ON LAYOUT IS DIAGRAMMATIC AND TO BE USED AS A

GUIDE ONLY. COORDINATE INSTALLATIONS WITH FIELD CONDITIONS AND EXISTING

UNDERGROUND UTILITIES.

PROPOSED POLE LIGHT

TYPE "P" WITH INTEGRAL

RECEPTACLE (TYP.)

1 1/4"C

4-#6

3-#10

CKTS A-10,12,14 & A-16

Horz. Scale: 1"=

0

#8-THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE ELECTRICAL SERVICE

INSTALLATION WITH THE LOCAL POWER COMPANY AND COMPLY WITH ALL

REQUIREMENTS AND SPECIFICATIONS OF THE LOCAL POWER COMPANY.

KEITH LAWSON

LEXINGTON ELECTRIC COMPANY

731-967-7321

([email protected]

CONCRETE COMPOSITE

PULLBOX (TYP.)

P

(L) A-10,12

(R) A-14

1"C

EMPTY W/ PULLWIRE

1 1/4"C

4-#6

3-#10

CKTS A-9,11,A-13 & A-15

P

(L) A-9,11

(R) A-13

P

(L) A-9,11

(R) A-13

P

(L) A-9,11

(R) A-13

P

(L) A-9,11

(R) A-13

P

(L) A-1,3

(R) A-5

P

(L) A-1,3

(R) A-5

P

(L) A-1,3

(R) A-5

P

(L) A-10,12

(R) A-14

P

(L) A-10,12

(R) A-14

P

(L) A-10,12

(R) A-14

P

(L) A-2,4

(R) A-6

P

(L) A-2,4

(R) A-6

P

(L) A-2,4

(R) A-6

P

(L) A-2,4

(R) A-6

E1

.2

MA

TC

HL

IN

E S

TA

:9

+1

5.0

0 S

EE

S

HE

ET

E

1.3

1"C

EMPTY W/ PULLWIRE

1"C

EMPTY W/ PULLWIRE

1 1/4"C

4-#6

3-#10

CKTS A-1,3, A-5 & A-7

1 1/4"C

4-#6

3-#10

CKTS A-1,3, A-5 & A-7

1 1/4"C

4-#6

3-#10

CKTS A-2,4, A-6 & A-8

1 1/4"C

4-#6

3-#10

CKTS A-2,4, A-6 & A-8

SEE ENLARGEMENT

THIS SHEET

1"C

EMPTY W/ PULLWIRE

1"C

EMPTY W/ PULLWIRE

THIS POLE LIGHT

SHOWN ON SHEET

NO. E-1.1

TO POLE LIGHTS

AND RECEPTACLES

TO PULL BOX

1"C

EMPTY W/ PULLWIRE

1 1/4"C

4-#6

3-#10

CKTS A-10,12A-14 & A-16

1"C

EMPTY W/ PULLWIRE

#6 CU. GND.

5/8" X 8FT COPPER

CLAD GND ROD

1 1/4"C

4-#6

3-#10

CKTS A-2,4, A-6 & A-8

PROPOSED CONCRETE

COMPOSITE PULL BOX

PROPOSED METER

BASE AND ENCLOSURE.

SEE RISER DETAIL ON

SHEET NO. E1.4

1 1/4"C

4-#6

3-#10

CKTS A-2,4, A-6 & A-8

TO PULL BOX

ENLARGEMENT

SCALE: 3/8" = 1'-0"

#9-SEE POLE BASE DETAIL ON SHEET NO. E1.5.

1"C

2-#6

1-#10

CKTS A-23

TO EXISTING POWER COMPANY

POLE APPROXIMATELY 120 FT.

3"C.

EMPTY W/ PULLWIRE

INSTALLED PER POWER

COMPANY REQUIREMENTS.

TO TRAFFIC SIGNAL

CONTROLLER

TO EXISTING POWER

COMPANY POLE

3"C.

EMPTY W/ PULLWIRE

INSTALLED PER

POWER COMPANY

REQUIREMENTS

1"C

EMPTY W/ PULLWIRE

TO PULL BOX

1 1/4"C

4-#6

3-#10

CKTS A-1,3, A-5 & A-7

1"C

2-#6

1-#10

CKTS A-23

1 1/4"C

4-#6

3-#10

CKTS A-9,11,A-13 & A-15

1"C

2-#6

1-#10

CKTS A-23

1 1/4"C

4-#6

3-#10

CKTS A-9,11,A-13 & A-15

1 1/4"C

4-#6

3-#10

CKTS A-10,12A-14 & A-16

1"C

EMPTY W/ PULLWIRE

2" CONDUIT INSTALLED ACROSS

ROAD BY DIRECTIONAL BORE FOR

OWNERS USE. STUB OUT ON EACH

SIDE OF ROADWAY AND CAP.

REVISIONS

CONSULTANT

TLM

ASS

OC

IATE

S, IN

C.

ARC

HIT

ECTS

+ E

NG

INEE

RS

731.

988.

9840

(pho

ne) -

731

.988

.995

9 (fa

x)11

7 Ea

st L

aFay

ette

Stre

et

Jack

son,

Tenn

esse

e 38

301

ww

w.tl

mae

.com

DESC

RIPT

ION

NO

.DA

TEBY

May 6, 2019

J5764

PARS

ON

S (S

R-20

)DO

WN

TOW

N E

NHA

NC

EMEN

TS

CIT

Y O

F PA

RSO

NS

for

TYPE YEARPROJECT NO.

SHEET

NO.

COORDINATES ARE NAD/83(1995),

ARE DATUM ADJUSTED BY THE

FACTOR OF 1.00007 AND TIED TO

THE TGRN. ALL ELEVATIONS ARE

REFERENCED TO THE NAVD 1988.

ELEC

TRIC

AL

SITE

PLA

N

E1.2

Pars

ons,

Tenn

esse

e

PHA

SE V

2020CONST TAP-2000(17)

E1.1

MICHAEL MCCORMICK, P.E.ELECTRICAL ENGINEER

COMMERCIALINDUSTRIALRELIGIOUS

[email protected]

05/06/19

ADD

END

UM

#1

12/5/2020

AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
20
AutoCAD SHX Text
80
AutoCAD SHX Text
MAGNETIC
Page 4: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com

31.00'

33.00'

W

HE

AT

S

TR

EE

T

CKP PROPERTIES

C

A

M

D

E

N

H

W

Y

JOHN R. LONG

BURNSY PROPERTIES, LLC

EXISTING R.O.W.

EXISTING R.O.W.

KYLE L.

TOWNSEND

PARSONS TELEPHONE

COMPANY, INC.

(U.S. 412) T.N. 20

20LPLM-F3-009

END PROJECT NO.

TAP-2000(17) STA:13+40.27

(U.S. 412, TN-20)

N 486238.6615 E 1337984.4989

7

9

10

6

N86°2

1'1

7"E

37.1

6'

Horz. Scale: 1"=

0

20

E1

.3

MA

TC

HL

IN

E S

TA

:9

+1

5.0

0 S

EE

S

HE

ET

E

1.2

1 1/4"C

4-#6

3-#10

CKTS A-2,4, A-6 & A-8

1"C

EMPTY W/ PULLWIRE

P

(L) A-1,3

(R) A-5

P

(L) A-1,3

(R) A-7

P

(L) A-1,3

(R) A-7

P

(L) A-1,3

(R) A-7

P

(L) A-1,3

(R) A-7

P

(L) A-2,4

(R) A-6

P

(L) A-2,4

(R) A-8

P

(L) A-2,4

(R) A-8

P

(L) A-2,4

(R) A-8

P

(L) A-2,4

(R) A-8

1 1/4"C

2-#6

3-#10

CKTS A-2,4 & A-8

1"C

EMPTY W/ PULLWIRE

CONCRETE COMPOSITE

PULLBOX (TYP.)

PROPOSED POLE LIGHT

TYPE "P" WITH INTEGRAL

RECEPTACLE (TYP.)

1"C

EMPTY W/ PULLWIRE

1 1/4"C

4-#6

3-#10

CKTS A-1,3, A-5 & A-7

1"C

2-#6

3-#10

CKTS A-1,3 & A-7

1"C

EMPTY W/ PULLWIRE

#1-ALL UNDERGROUND CONDUIT SHALL BE A MINIMUM OF 1 INCH.

ELECTRICAL NOTES:

#2-ALL CONDUIT SHALL BE INSTALLED BY DIRECTIONAL BORING AT ROADWAY AND DRIVEWAY

CROSSINGS WHERE PAVEMENT OR CONCRETE IS NOT BEING REPLACED.

#3-ALL STREET LIGHTING CIRCUITS TO BE ROUTED THROUGH LIGHTING CONTACTORS AND

CONTROLLED BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER

OFF OPERATION.

#4-ALL POLE RECEPTACLE CIRCUITS TO BE ROUTED THROUGH CONTACTORS AND CONTROLLED

BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER OFF

OPERATION.

#5-EACH POLE RECEPTACLE NOT TO EXCEED 180 WATTS AND SHALL BE EITHER A WEATHER

RESISTANT GFCI RECEPTACLE OR CONNECTED TO GFCI CIRCUIT BREAKER PROTECTED

BRANCH CIRCUIT.

#6-POLE MOUNTED RECEPTACLES TO HAVE HEAVY DUTY CAST ALUMINUM "WHILE IN USE"

COVER PAINTED TO MATCH POLE FINISH.

#7-CONDUIT ROUTING AS SHOWN ON LAYOUT IS DIAGRAMMATIC AND TO BE USED AS A

GUIDE ONLY. COORDINATE INSTALLATIONS WITH FIELD CONDITIONS AND EXISTING

UNDERGROUND UTILITIES.

#8-SEE POLE BASE DETAIL ON SHEET NO. E1.5.

REVISIONS

CONSULTANT

TLM

ASS

OC

IATE

S, IN

C.

ARC

HIT

ECTS

+ E

NG

INEE

RS

731.

988.

9840

(pho

ne) -

731

.988

.995

9 (fa

x)11

7 Ea

st L

aFay

ette

Stre

et

Jack

son,

Tenn

esse

e 38

301

ww

w.tl

mae

.com

DESC

RIPT

ION

NO

.DA

TEBY

May 6, 2019

J5764

PARS

ON

S (S

R-20

)DO

WN

TOW

N E

NHA

NC

EMEN

TS

CIT

Y O

F PA

RSO

NS

for

TYPE YEARPROJECT NO.

SHEET

NO.

COORDINATES ARE NAD/83(1995),

ARE DATUM ADJUSTED BY THE

FACTOR OF 1.00007 AND TIED TO

THE TGRN. ALL ELEVATIONS ARE

REFERENCED TO THE NAVD 1988.

ELEC

TRIC

AL

SITE

PLA

N

E1.3

Pars

ons,

Tenn

esse

e

PHA

SE V

2020CONST TAP-2000(17)

E1.1

MICHAEL MCCORMICK, P.E.ELECTRICAL ENGINEER

COMMERCIALINDUSTRIALRELIGIOUS

[email protected]

05/06/19

11AD

DEN

DU

M #

12/5/2020

AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
80
AutoCAD SHX Text
MAGNETIC
Page 5: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com

PANEL DESIGNATION

VOLTAGE AND PHASE

PANEL BUS SIZE

MAIN TYPE

PANEL MOUNTING

..............

.............

......................

................................

...................

FEED

CKT.

NO.

C.B.

TRIP

CKT.

NO.

C.B.

TRIP

FEED

A Ø

LOAD IN KW

TOTAL KW / PHASE

TOTAL AMPS / PHASE

B Ø

TOTAL KW

TOTAL AMPS

NO.

POLES

NO.

POLES

SYMBOL SCHEDULE

SYMBOL

DESCRIPTION

ORJUNCTION OR PULLBOX. SIZE AS REQUIRED.

PHOTO ELECTRIC CELL LIGHTING CONTROL MOUNTED ON ROOF.

'L' PANEL. 120/208V. 3Ø, 4W LOW VOLTAGE LIGHTING AND POWER DISTRIBUTION PANEL.

RACEWAY WITH CONDUCTORS RUN CONCEALED IN FLOOR SLAB, IN WALLS OR IN EARTH.

RACEWAY WITH CONDUCTORS RUN EXPOSED, PARALLEL / RIGHT ANGLES TO STRUCTURE.

RACEWAY FOR TELEPHONE CABLES INSTALLED BY TELEPHONE COMPANY.

BARE GROUND CONDUCTOR UNDERGROUND. SIZE AS NOTED ON PLANS.

RACEWAY WITH CONDUCTORS RUN CONCEALED ABOVE CEILING OR IN WALLS

INSULATED GREEN GROUND CONDUCTOR. SAME SIZE AS PHASE WIRE UNLESS NOTED.

-

-

8.06.6

.

.

.

.

.

.

.

.

.

1.8

0.1

.

.

0.9

0.9

0.8

0.8

0.7

0.7

0.7

0.7

20

20

12

10

20

20

20

20

18

16

22

20

20

20

20

20

28

26

30

-

-

24

20 14

"A"

120/240V, 1Ø, 3W

125 AMP

100A2P MAIN CKT. BKR. & SN

NEMA-1 SURFACE

1

3

5

7

9

11

20

20

20

20

20

20

NE POLE LTS

15

17

19

21

25

27

29

23

20

20

20

20

40

-

-

-

13 20

SE POLE LIGHTS

.

.

.

.

.

.

.

.

.

.

.

.

.

0.8

0.9

0.8

0.8

0.7

0.9

0.8

0.8

66.755.0

2

2

1

1

1

-

-

-

1

2

2

1

-

-

-

-

NW POLE LIGHTS

NW POLE RECEPTACLES

NW POLE RECEPTACLES

SW POLE LIGHTS

SW POLE RECEPTACLES

SPACE ONLY

SPACE ONLY

14.6

60.8

FINISHED GRADE

METER BASE

RISER DETAIL

NOT TO SCALE

ANCHOR

EQUIPMENT

ENCLOSURE TO

CONCRETE BASE

PROVIDE NEMA 4X-SS ENCLOSURE WITH

PAD LOCKABLE THREE POINT LATCH. SEE

ENCLOSURE INTERIOR DETAIL THIS SHEET.

POWER

COMPANY

POLE

COORDINATE SERVICE

ENTRANCE RISER

INSTALLATION WITH POWER

COMPANY

ENCLOSURE INTERIOR DETAIL

NOT TO SCALE

METER

BASE

PANELBOARD

IN NEMA 1

ENCLOSURE

30 AMP, 4 POLE LIGHTING

CONTACTORS IN NEMA 1

ENCLOSURE FOR LIGHTING

CIRCUITS (PROVIDE QUANTITY

AS REQUIRED)

30 AMP, 4 POLE LIGHTING

CONTACTOR IN NEMA 1

ENCLOSURE FOR POLE

RECEPTACLE CIRCUITS

(PROVIDE QUANTITY AS

REQUIRED)

1 1/4" C

3 - #3

1 - #6

OUT GOING

CONDUITS

(NOT ALL

SHOWN)

T

LC

LC

LC

LC

PCPC

TIMER

PHOTO CELL (TYP)

#6 CU GND

3"C

EMPTY W/ PULLWIRE

INSTALLED PER POWER

COMPANY REQUIREMENTS.

36" MIN.

18" MIN.

5/8" X 8'-0"

COPPERCLAD

GND ROD

NOTE: THIS IS A STANDARD SYMBOLS SCHEDULE. ALL SYMBOLS SHOWN ON THIS SCHEDULE MAY NOT

APPEAR IN THIS SET OF DRAWINGS.

#2-ALL STREET LIGHTING CIRCUITS TO BE ROUTED THROUGH LIGHTING CONTACTORS AND

CONTROLLED BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER

OFF OPERATION.

THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE ELECTRICAL SERVICE INSTALLATION

WITH THE LOCAL POWER COMPANY AND COMPLY WITH ALL REQUIREMENTS AND

SPECIFICATIONS OF THE LOCAL POWER COMPANY.

KEITH LAWSON

LEXINGTON ELECTRIC COMPANY

731-967-7321

([email protected]

#1-

ELECTRICAL NOTES:

#3-ALL POLE RECEPTACLE CIRCUITS TO BE ROUTED THROUGH CONTACTORS AND CONTROLLED

BY PHOTOELECTRIC CELL AND TIMER FOR PHOTOELECTRIC CELL ON AND TIMER OFF

OPERATION.

#4-EACH POLE RECEPTACLE NOT TO EXCEED 180 WATTS AND SHALL BE EITHER A WEATHER

RESISTANT GFCI RECEPTACLE OR CONNECTED TO GFCI CIRCUIT BREAKER PROTECTED

BRANCH CIRCUIT.

#5-CONDUIT ROUTING AS SHOWN ON LAYOUT IS DIAGRAMMATIC AND TO BE USED AS A GUIDE

ONLY. COORDINATE INSTALLATIONS WITH FIELD CONDITIONS AND EXISTING UNDERGROUND

UTILITIES.

NE POLE RECEPTACLES

NE POLE RECEPTACLES

2

1

1

SPARE

CONTROL CIRCUIT

TRAFFIC SIGNAL CONTROLLER

2SPARE

1

SPARE

1SPARE

1SE POLE RECEPTACLES

4

2

8

6

SE POLE RECEPTACLES

SW POLE RECEPTACLES

T

POLE MOUNTED LUMINAIRE.

REVISIONS

CONSULTANT

TLM

ASS

OC

IATE

S, IN

C.

ARC

HIT

ECTS

+ E

NG

INEE

RS

731.

988.

9840

(pho

ne) -

731

.988

.995

9 (fa

x)11

7 Ea

st L

aFay

ette

Stre

et

Jack

son,

Tenn

esse

e 38

301

ww

w.tl

mae

.com

DESC

RIPT

ION

NO

.DA

TEBY

May 6, 2019

J5764

PARS

ON

S (S

R-20

)DO

WN

TOW

N E

NHA

NC

EMEN

TS

CIT

Y O

F PA

RSO

NS

for

TYPE YEARPROJECT NO.

SHEET

NO.

COORDINATES ARE NAD/83(1995),

ARE DATUM ADJUSTED BY THE

FACTOR OF 1.00007 AND TIED TO

THE TGRN. ALL ELEVATIONS ARE

REFERENCED TO THE NAVD 1988.

ELEC

TRIC

AL

SITE

PLA

N

E1.4

Pars

ons,

Tenn

esse

e

PHA

SE V

2020CONST TAP-2000(17)

E1.1

MICHAEL MCCORMICK, P.E.ELECTRICAL ENGINEER

COMMERCIALINDUSTRIALRELIGIOUS

[email protected]

05/06/19

ADD

END

UM

#1

12/5/2020

AutoCAD SHX Text
J
AutoCAD SHX Text
T
AutoCAD SHX Text
J
AutoCAD SHX Text
PC
Page 6: TENNESSEE AVE NORTH (HWY 641) · 1"c 2-#6 1-#10 ckt a-23 const 2020 tap-2000(17) e1.1 michael mccormick, p.e. electrical engineer commercial industrial religious michaelmccormickpe@gmail.com

Luminaire Schedule

Symbol Label Quantity Manufacturer

36 STERNBERG

VINTAGE

LIGHTING

P

Catalog Number Description

A783BA 5PPT 150MH

240V RAL6012

CAST ALUMINUM HOUSING, SPUN

WHITE ENAMEL ALUMINUM

REFLECTOR ABOVE CLEAR

PRISMATIC ACRYLIC REFRACTOR.

Lamp

ONE CLEAR VBD M57 150

WATT ED17 METAL

HALIDE LAMP RATED AT

14,000 LUMENS.

Number

Lamps

1

Lumens Per

Lamp

14000

Light Loss

Factor

1

Wattage

150

Statistics

Description

N. Sidewalk

S. Sidewalk

Street

Symbol Avg Max Min Max/Min Avg/Min

2.1 fc 2.6 fc 1.2 fc

2.1 fc 2.7 fc 1.0 fc

3.1 fc 4.7 fc 1.1 fc

2.2:1

2.7:1

4.3:1

1.8:1

2.1:1

2.8:1

D

D

36.00'

31.00'

33.00'

33.00'

45.00'

50.00'

31.00'

W

HE

AT

S

TR

EE

T

T

E

N

N

E

S

S

E

CKP PROPERTIES

TE

NN

ES

SE

E A

VE

N

OR

TH

(H

WY

641)

(U

.S

. 4

1

2

) T

.N

. 2

0

C

A

M

D

E

N

H

W

Y

FARMERS BANK

ALESHA VANDIVER

JOHN R. LONG

JOHN R. LONG

KAYLA INVESTMENTS, LLC

TENNESSEE VALLEY FORD, INC.

GRAVES PROPERTIES

D.C

. PR

OPER

TIES

BURNSY PROPERTIES, LLC

CHARLES E. PHILPOTT

EXISTING R.O.W.

EXISTING R.O.W.

EXISTING R.O.W.

FARMERS BANK

EXISTING R.O.W.

EXISTING R.O.W.

EXISTING R.O.W.

PHILIP BREAZEALE

AND WIFE SHEARON

BRAZEALE

GORDON MIKE FERGUSON

& JAMES G. FERGUSON

20LPLM-F3-009

BEGIN PROJECT NO.

TAP-2000(17)

STA:0+00.00

(U.S. 412, TN-20)

KYLE L.

TOWNSEND

PARSONS TELEPHONE

COMPANY, INC.

(U.S. 412) T.N. 20

20LPLM-F3-009

END PROJECT NO.

TAP-2000(17) STA:13+40.27

(U.S. 412, TN-20)

N 486238.6615 E 1337984.4989

GE

OR

GIA

A

VE

N

2

3

4

5

7

8

9

10

6

11

12

13

14

15

16

17

(U

.S. 412) T

.N

. 20

1.7

1.4

1.3

1.3

1.9

2.8

2.6

2.0

1.5

1.4

1.9

2.7

2.6

2.0

1.7

2.2

2.8

3.1

3.0

2.4

1.8

2.0

2.6

2.9

3.7

2.4

1.9

2.0

2.1

2.2

2.3

2.1

1.9

2.3

1.9

2.2

2.1

2.0

2.2

2.1

2.6

4.1

2.6

2.7

2.1

2.3

3.1

3.5

3.1

3.0

2.4

2.4

3.0

3.6

2.2

3.1

2.5

2.2

2.7

3.4

3.0

2.5

2.1

2.4

2.6

2.9

2.9

2.2

2.4

2.3

1.9

2.5

2.3

2.2

2.5

2.4

2.3

3.1

2.4

2.3

2.4

2.8

3.3

3.2

2.9

2.5

2.4

2.8

3.6

2.8

3.7

3.1

2.6

2.8

3.2

3.5

3.3

3.4

2.9

2.6

3.1

3.3

3.5

3.0

2.5

2.4

2.6

2.1

3.4

2.9

2.6

2.5

2.3

3.1

2.9

2.9

2.4

2.6

3.2

3.6

3.4

3.0

2.7

3.0

3.7

3.6

3.9

3.3

3.2

3.7

3.0

2.8

3.8

3.2

3.0

3.4

4.1

3.6

3.2

2.8

2.9

3.2

3.4

2.7

2.7

2.6

2.8

2.1

2.7

2.6

2.7

3.1

3.7

3.5

3.2

3.0

3.5

3.7

4.2

3.6

3.4

3.6

3.7

3.8

3.3

3.3

3.9

3.8

3.3

3.2

3.2

3.1

3.9

3.2

2.8

2.7

2.7

2.9

2.7

2.9

3.8

3.7

3.2

3.5

3.7

4.2

3.7

3.7

3.9

2.9

3.6

4.4

4.1

4.0

3.7

3.0

4.0

3.4

3.6

4.0

3.4

3.0

2.9

3.3

4.4

3.1

2.6

2.9

3.9

3.7

3.2

3.4

4.7

2.8

4.1

3.7

3.7

4.0

4.1

3.7

3.8

4.1

3.3

3.2

3.5

4.0

3.2

2.8

3.1

3.2

3.1

2.1

3.0

2.7

2.4

3.1

2.5

3.2

2.8

3.0

3.5

3.2

3.2

3.4

3.9

3.6

3.5

3.5

4.0

2.6

3.3

3.6

3.4

4.0

4.1

3.9

3.4

3.2

3.3

3.9

2.8

3.0

2.6

2.7

3.0

3.0

2.6

2.7

3.6

3.4

3.3

3.3

3.5

3.7

3.4

3.5

3.9

3.5

4.0

3.7

4.0

2.9

3.9

3.6

3.4

3.8

3.7

4.0

3.2

2.9

3.0

3.2

2.4

2.7

2.5

2.5

3.2

3.0

2.7

3.2

3.5

3.5

3.4

3.4

3.7

3.6

3.5

3.6

4.1

3.7

3.3

3.3

3.8

3.7

3.4

3.2

3.2

3.6

3.1

2.8

3.0

2.2

2.4

2.6

2.6

2.9

2.3

2.9

3.1

3.0

3.1

3.4

3.5

3.5

3.5

3.5

4.0

2.8

3.7

3.6

4.0

3.1

3.7

3.5

3.6

3.7

3.6

3.4

3.4

3.7

3.5

2.6

2.6

3.4

3.2

2.6

2.6

3.4

3.4

3.3

3.4

3.4

3.6

3.4

3.4

3.8

3.4

3.9

3.5

3.8

3.7

3.4

3.4

3.7

4.0

3.2

3.0

3.1

2.8

2.8

2.6

2.6

2.7

2.1

2.7

2.8

2.6

2.9

2.8

3.6

3.1

3.2

3.1

4.5

3.8

3.9

3.3

3.5

3.5

2.5

3.7

3.4

3.8

3.1

3.8

3.2

3.2

3.8

3.2

2.9

3.0

3.6

3.0

2.5

2.6

2.8

3.1

2.6

2.7

3.4

3.2

3.2

3.2

3.3

3.5

3.2

3.2

3.6

3.5

3.7

3.4

3.8

3.6

3.3

3.3

3.8

3.8

3.1

3.0

3.2

2.6

2.9

2.7

2.6

2.8

2.2

2.8

2.9

2.7

3.1

2.8

4.0

3.3

3.4

3.5

4.3

4.2

4.1

3.6

4.0

3.4

2.8

4.1

3.9

4.1

3.4

3.7

4.1

3.5

3.6

4.3

2.8

3.2

2.8

2.9

3.8

3.3

2.5

2.7

3.7

3.4

3.3

3.5

3.8

4.0

3.7

3.7

4.0

4.1

3.9

3.9

4.0

4.0

3.6

3.7

4.0

3.6

3.2

3.1

3.5

3.1

2.6

2.6

2.9

3.7

2.9

2.9

3.3

4.2

3.4

3.5

3.6

3.1

3.5

3.7

3.5

3.7

2.6

3.1

3.8

3.4

3.7

3.1

3.9

3.3

3.3

3.2

3.8

3.1

3.0

2.7

2.9

2.6

2.1

2.5

2.3

2.5

2.1

2.3

2.9

2.5

2.7

3.2

3.0

2.9

3.0

2.8

3.6

3.0

2.8

3.0

2.6

2.7

2.4

2.6

2.8

2.3

2.0

2.0

2.5

1.8

1.3

1.4

2.1

1.1

1.8

1.8

2.1

1.9

1.5

1.7

2.4

2.2

2.2

2.3

1.6

1.2

1.7

2.3

2.1

2.3

2.2

1.5

1.4

2.2

2.4

2.3

2.4

1.9

1.4

1.8

2.4

2.3

2.4

2.4

1.7

1.5

2.1

2.6

2.4

2.5

2.3

1.6

1.8

2.5

2.5

2.4

2.4

1.8

1.5

2.1

2.5

2.3

2.4

2.2

1.4

1.5

2.3

2.5

2.5

2.4

2.0

1.5

1.9

2.4

2.4

2.4

2.3

1.5

1.3

1.8

2.4

2.3

2.4

2.4

1.8

1.5

2.0

2.5

2.4

2.5

2.2

1.5

1.4

2.1

2.4

2.2

2.4

2.2

1.4

1.3

2.0

2.4

2.3

2.4

2.3

1.6

1.5

2.2

2.6

2.5

2.5

2.2

1.7

2.1

2.5

2.6

2.6

2.3

1.5

1.6

2.3

2.4

2.3

2.4

2.0

1.2

1.3

2.0

2.1

1.8

1.7

1.3

1.5

1.9

1.6

2.1

2.0

1.3

1.4

2.0

2.4

2.42.5

2.4

1.8

1.9

2.6

2.6

2.5

2.5

2.1

1.8

2.3

2.5

2.5

2.6

2.0

1.4

1.6

2.4

2.3

2.3

2.4

1.9

1.4

1.6

2.4

2.3

2.3

2.5

1.9

1.5

1.7

2.5

2.4

2.4

2.5

2.0

1.6

2.0

2.5

2.42.5

2.6

1.8

1.7

2.0

2.5

2.22.6

2.6

1.9

2.0

2.5

2.5

2.4

2.5

1.9

1.4

1.9

2.3

2.3

2.3

2.3

1.7

1.3

1.8

2.5

2.6

2.2

2.3

2.4

2.5

2.3

2.5

2.7

2.0

1.6

1.9

2.5

2.3

2.4

2.4

1.7

1.5

2.2

2.6

2.4

2.3

2.2

2.0

2.1

2.0

2.3

2.2

1.6

1.0

1.2

1.7

2.0

1.9

2.0

2.0

1.2

1.2

1.9

2.1

1.8

1.8

1.5

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

'P'

LUMINAIRE SCHEDULE

MARK LAMPS VOLTS MOUNTING FINISHSPECIFICATIONS

NOTES

240

@ 14,000 LUMENS

150W METAL HALIDE

THIS SHEET

SEE DETAIL POWDERCOAT

RAL: 6012

ROUND FLUTED TAPERED DECORATIVE POST AND BASE W/ ALUMINUM REFLECTOR AND ACRYLIC LENS.

STERNBERG VINTAGE LIGHTING #A783-5PPT-150MH-240V-RAL6012. POST TOP ACORN TYPE FIXTURE WITH

--

ALL LUMINAIRES AND POLES TO BE PROVIDED AND INSTALLED BY THE OWNER AND CONNECTED BY THE OWNER TO ELECTRICAL CONTRACTOR'S INSTALLED BRANCH CIRCUIT WIRING AT THE POLE BASES. PROPERLY LABEL ALL CONDUCTORS AT

EACH POLE BASE INDICATING CIRCUIT NUMBER AND RECEPTACLE OR LIGHT CIRCUIT.

REVISIONS

CONSULTANT

TLM

ASS

OC

IATE

S, IN

C.

ARC

HIT

ECTS

+ E

NG

INEE

RS

731.

988.

9840

(pho

ne) -

731

.988

.995

9 (fa

x)11

7 Ea

st L

aFay

ette

Stre

et

Jack

son,

Ten

ness

ee 3

8301

ww

w.tl

mae

.com

DES

CRI

PTIO

NN

O.

DA

TEBY

May 6, 2019

J5764

PARS

ON

S (S

R-20

)D

OW

NTO

WN

EN

HAN

CEM

ENTS

CITY

OF

PARS

ON

Sfo

r

TYPEYEAR

PROJECT NO.

SHEET

NO.

COORDINATES ARE NAD/83(1995),

ARE DATUM ADJUSTED BY THE

FACTOR OF 1.00007 AND TIED TO

THE TGRN. ALL ELEVATIONS ARE

REFERENCED TO THE NAVD 1988.

ELEC

TRIC

AL

SITE

PLA

N

E1.5

Pars

ons,

Tenn

esse

e

PHA

SE V

2020CONST TAP-2000(17)

E1.1

MICHAEL MCCORMICK, P.E.ELECTRICAL ENGINEER

COMMERCIALINDUSTRIALRELIGIOUS

[email protected]

05/06/19

SECTION AT POLE BASE

4 #8's VERT.

AT THE TOP

6" C/C EXCEPT

#3 TIE BARS AT

LUMINAIRE

FROM NEXT

CONDUIT TO OR

Ø

6"

NTS

5'-0

"

2'-6

"

EACH POLE

GROUND ROD AT

COPPERCLAD

5/8"Ø X 8' LONG

DIAMETER / WIDTH

1"

6" T

YP

.6

"1

"1

"

TYPICAL

CONDUIT

4"

TYPICAL

ANCHOR BOLT

TO POLE BASE

GROUND LUG

#4 BARE GROUND

IN 1" C. CONNECT

OR PAVING

FINISH GRADE

TO BE 3000 PSI

CONCRETE MIXTURE

1

1

COORDINATE POLE BASE TOP DIMENSION AND SHAPE WITH LANDSCAPE ARCHITECT DRAWINGS.

PLAN VIEW OF POLE BASE

NTS

TYPICAL

CONDUIT

TYPICAL

ANCHOR BOLT

V

E

R

I

F

Y

DIAMETER

& SIDES SMOOTH

RUB EXPOSED TOP

COORDINATE POLE BASE

TOP DIMENSION AND

SHAPE WITH LANDSCAPE

ARCHITECT DRAWINGS

1AD

DEN

DU

M #

12/5/2020

AutoCAD SHX Text
1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
0
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
100
AutoCAD SHX Text
50
AutoCAD SHX Text
200
AutoCAD SHX Text
25
AutoCAD SHX Text
MAGNETIC

Recommended