User Instructions For TopTronic ® RS-30 430294ENG-Jun02 Hoval Ltd Northgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532
Transcript
Page 1: termostat Hoval

User Instructions For TopTronic® RS-30 430294ENG-Jun02

Hoval Ltd Northgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532

Page 2: termostat Hoval

2 Index 430294ENG-Jun02 Introduction Introduction ....................................................................................................................................... 3 Controls............................................................................................................................................. 3 Display .............................................................................................................................................. 3 User instructions Key function table.............................................................................................................................. 4 Switching on the room station ........................................................................................................... 4 Additional information........................................................................................................................ 5 Automatic program selection ............................................................................................................. 5 Room temperature ............................................................................................................................ 6 Heating program ............................................................................................................................... 7 Calorifier charging ............................................................................................................................. 9 Advanced user instructions Language .......................................................................................................................................... 10 Clock setting...................................................................................................................................... 10 Time clock level................................................................................................................................. 10 Time clock programming ................................................................................................................... 11 Block programming ........................................................................................................................... 14 Table program 1 settings................................................................................................................... 17 Table program 2 settings................................................................................................................... 18 Table program 3 settings................................................................................................................... 19 Room level ........................................................................................................................................ 20 Parameter tables Room level parameters table............................................................................................................. 23 Advanced parameter table ............................................................................................................... 24 Installation / technical Installation......................................................................................................................................... 25 Technical data................................................................................................................................... 25

Page 3: termostat Hoval

430294ENG-Jun02 Introduction 3 The RS-30 has the most modern technology and serves as a weather / room temperature regulator with integrated hot water control and remote operating functions for the UltraGas or Topgas boilers. With the most up to date micro electronics exclusive functions can be activated which guarantee the highest level of comfort with the minimum energy usage. This is achieved with adaption and optimization functions which match heating energy to the exact building requirements. As well as these room temperature related functions a variety of equipment specific information is available which can be read within the living room and when necessary adapted to individual circumstances. This encompasses dates, on/off switching of the heating cycle with differently regulated room temperatures, actual values and diagnostic fault messages of the boiler. Operation of the unit is easy to understand and is limited to a minimum of operating elements which are separated for user and advanced user levels. The instructions are separated into two parts. Part 1 (user instructions) delivers all immediately important operating stages which are necessary for use and are selected with directly accessible operating keys. Part 2 (advanced instructions) these should only be used by the advanced user or service engineer and relate to specific settings / heating parameters and are accessible by the covered operating keys. Controls 1 4 2 5 3 6 7 10 12 11 13 8 9 1 – LCD Display 2 – Key (increase value) 3 – Key (decrease value) 4 – Key for heating program 5 – Key for reduced (night time) program 6 – Information 7 – Program key (time/date) 8 – Program key (automatic programs) 9 – Program key (house level) 10 – Program key (service level) 11 – Forward key 12 – Backward key 13 – Cover

Symbol Display Heating Night setback Room temperature

Page 4: termostat Hoval

4 User Instructions 430293ENG-Dec01

Key Function table (User Level)

Function Enter with keys Adjust with keys / range Page No.

Room temperature correction

or

or

5…30oC ??

Heating (day) room temperature

or with

or

5…30oC ??

Reduced (night) room temperature

or with

or

5…30oC ??

Information ??

Party function

press and hold or

0.5…10h ??

Continuous heating

press and hold

or

5…30oC ??

Absent function

press and hold or

0.5…10h ??

Continuous reduced

press and hold or

5…30oC ??

Heating Off (manual summer operation)

press and hold

or On, Off

??

Automatic

or ??

Calorifier charging

and

simultaneously

ON or

OFF ??

Automatic programs 1-3 and

simultaneously

or

1, 2, 3 ??

Switching on the Room station When the room station is first switched on the following display will show for 5 seconds: Room Station Software version Control type The default display will then appear. The symbol indicates that the room station is in heating operation and the symbol indicates

the room station is in reduced (night time) operation.

Information: Monday 10th March 1997 Time 20.15 Room temperature 20.5oC Clock synchronisation

i

Page 5: termostat Hoval

430294ENG-Jun02 User Instructions 5 Attention:

�� During summer switch off the following symbols are not shown and .

�� Blinking symbols or indicate that the unit is not operating under a normal program eg. party.

Additional Information The following additional information can be obtained by pressing the button (only if the relevant sensors are fitted):

Default display.

External sensor temperature.

Flow temperature.

Boiler return temperature.

Domestic hot water temperature.

If the calorifier is fitted with a thermostat instead of a sensor the following will be displayed:

Calorifier on/off.

Default display.

Fault Indications The RS-30 room station has a comprehensive fault indication system which has priority over all other indications and remain active until the fault is rectified. Faults concerning the firing unit must be rectified in accordance with operating manual instructions. If any of the following fault displays are shown (Fault – System Off, Fault – Hot water temperature, Fault – Boiler temperature, Fault – Room temperature ) you must notify the heating engineer. Automatic Program Selection In automatic there are three different time programs to switch between for the heating. As a general rule these can be used without the need for adjustment but if individual programs are required customised cycles can be entered (see the advanced user section ). Program 1

Day Heating on time

Mo – Fr Sa, Su

6.00 - 8.00 16.00 - 22.00 7.00 - 23.00

2 – Program 2

Day Heating on time Mo – Su 6.00 - 22.00

Program 3

Day Heating on time

Mo – Su 6.00 - 23.00

i

i

i

i

i

i

Page 6: termostat Hoval

6 User Instructions 430294ENG-Jun02 Changing between Automatic Programs By using the and keys and following procedure it is possible to change between the automatic programs heating.

Press Simultaneously The following will be displayed for the default setting of program 2:

Use the and keys to change between programs 1, 2 or 3. After 4 secs the default display will be restored. Room Temperature By using the program keys and the increase / decrease value keys the room temperature can be changed for heating and reduced (night time). A – Heating (day room temperature) If in heating operation as indicated by on the display follow the procedure below: press or

Display for heating operation.

Works setting: 20oC Adjustment range: 5oC…30oC press to increase to decrease

Default screen automatically returns after 4 seconds.

If in reduced operation as indicated by on the display follow the procedure below:

press or

Display for reduced operation.

press

Display for heating temperature.

Works setting: 20oC Adjustment range: 5oC…30oC press to increase to decrease

Default screen automatically returns after 4 seconds.

B – Reduced (night room temperature) If in reduced operation as indicated by on the display follow the procedure below: press or

Display for reduced operation.

Works setting: 16oC Adjustment range: 5oC…30 oC press to increase to decrease

Default screen automatically returns after 4 seconds.

If in heating operation as indicated by on the display follow the procedure below:

Page 7: termostat Hoval

430294ENG-Jun02 User Instructions 7 press or

Display for heating operation.

press

Display for reduced operation.

Works setting: 16oC Adjustment range: 5oC…30oC press to increase to decrease

Default screen automatically returns after 4 seconds.

Heating Program With the two program keys and the following changes can be made to the programs:

A - Party B - Heating C - Absent D - Reduced E - Heating off

A – Party This program is used to switch on or extend the heating automatic program to a certain time for a one off event press and hold

Display for party program.

For example: At 20.15 the heating needs to be extended by 3 hours (to 23.15). press to increase to decrease Adjustment range 0.5…10h It should be noted that the adjustment is from the time of alteration and not an extension of the automatic program 1, 2 or 3. The default display will return after 4 seconds. To cancel party program The party program can be cancelled and put back into automatic by the following procedure: press and hold

The default display returns after 4 seconds. B - Heating This program is used to switch on the heating continuously. press and hold

The default display returns after 4 seconds.

Page 8: termostat Hoval

8 User Instructions 430294ENG-Jun02 To cancel heating program The continuous heating program can be cancelled using the following procedure: press and hold

The default display will return after 4 seconds. C – Absent This program is used to switch to reduced or extend the reduced automatic program to a certain time for a one off event press and hold

Display for absent program.

For example: At 13.00 the heating is switched to reduced for the next 6 hours (to 19.00). press to increase to decrease Adjustment range 0.5…10h It should be noted that the adjustment is from the time of alteration and not an extension of the automatic program 1, 2 or 3. The default display will return after 4 seconds. To cancel absent program The absent program can be cancelled and put back into automatic by the following procedure: press and hold

The default display will return after 4 seconds. D - Reduced This program is used to switch to reduced continuously. press and hold

The default display returns after 4 seconds. To cancel reduced program The continuous reduced program can be cancelled using the following procedure: press and hold

The default display will return after 4 seconds.

Page 9: termostat Hoval

430294ENG-Jun02 User Instructions 9 E – Heating Off This program enables the heating operation to be switched off without any danger of frost. With outside temperature below the set frost protection limit the heating cycle is regulated according to the minimum room temperature. The hot water generation remains in operation. Application: Manual summer operation

(heating off, hot water on) press and hold

The default display will return after 4 seconds. During this operation method the will blink To cancel heating off program The heating off program can be cancelled using the following procedure: press and hold

The default display will return after 4 seconds. Calorifier Charging With this program it is possible to switch the calorifier on for a fixed three hour period. press simultaneously

The default display will return after 4 seconds. To Cancel program: press simultaneously The default display will return after 4 seconds.

Page 10: termostat Hoval

10 Advanced User Instructions 430294ENG-Jun02 Language The room station is programmed in three languages English, German and French. To change the language press or key for 5 seconds. Once the language appears the keys can be used to change languages. or Works setting: ENGLISH The previous display will return in a few seconds. 1 - Clock setting The following functions can be set:

- Time (minutes, hours) - Day - Month - Year

The clock can be set to automatically change over from summer to winter time by a parameter in the service level of the central unit. Changing clock settings The clock can be changed by using key and then the and keys to increase or decrease the values. - Time

Change with: to increase to decrease Setting Range:

00:00 … 23:59 - Date

Change with: to increase to decrease Setting Range:

1 … 31

- Month

Change with: to increase to decrease Setting Range:

1 … 12 - Year

Change with: to increase to decrease Setting Range:

1995 … 2030 - Return to default display If the key is not pressed the default display will return after 2 minutes. It is possible to return to the default display at any time using the information key. 2 - Time clock level In the time clock level the individual program times can be customized. Standard heating programs 1, 2 and 3 can be called up as desired and overwritten with different switch times and temperatures. Each standard program can thus be configured individually and stored under the same program number so that three different programs are available on demand. These can then simply be called up in the user operating level see page 6 for setting of the automatic program. Note: Programming of room temperatures is only

possible if the relevant parameter has been enabled in the service level by an engineer.

If this has not been done it is only possible to change the on / off times. In this case the room temperature will be the works setting of 20ºC or the corrected value which has been set in the user level. The standard programs are lost when overwritten by customized programs. These are cancelled after a reset and replaced by the standard programs and therefore have to be recreated if needed.

Page 11: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 11 Room temperature correction for PARTY and HEATING with variable temperature parameter enabled. For operating types:

- PARTY - HEATING

The room temperature is set to automatic works setting of 20ºC or the corrected value which has been set in the user level. The actual room temperature values for each of these two operating types can be set independently to the automatic program if the relevant parameter has been enabled in the service level by an engineer. The value is set separately when calling up the operating type PARTY or HEATING by using the and keys. These values remain stored for each further call of this operating type. Time Clock Programming It is possible to program up to three cycles / periods for each desired weekday. 1 – Heating Cycle For heating each of these cycles has an on / off as well as a temperature indication for this time span. The temperature can only be adjusted if the relevant parameter is enabled in the service level. Between heating cycles the room temperature is regulated according to the night temperature. 2 – Hot Water Cycle For hot water each of these cycles has an on / off time. Between hot water cycles hot water heating is switch off. The temperature is set in the room level and cannot be changed for each cycle. Entering the time clock level Entering this level is achieved by simply pressing the key. The program 1, 2 or 3 which is set in the room level is shown.

Press key

Boiler circuit Works setting program 2

or

Boiler circuit Room level set to program 1

or

Boiler circuit Room level set to program 3

With the and the heating or hot water circuit can be called up and is available for programming. Calling up of heating cycles With a further pressing of the key the first heating cycle of the selected program shows complete with indication of weekday, cycle number, on time, off time and temperature. Each value is called up with the key in series

- On time - Off time - Temperature

The key can be used to step backwards. The current value which can be changed with the and keys is shown blinking. Switch times can be altered in 5 minute intervals and temperatures in 0.5K increments in the range of 5-30ºC. The next heating cycle can be called up by pressing the key and the process repeated. Note: The on/off times of not used heating cycles

should be set to 00:00 by simultaneously pressing the and keys. The 00:00 value does not refer to a clock time but only shows an undefined switch time.

After programming the last heating cycle (Sunday – cycle 3) the first heating cycle (Monday – cycle 1) will follow.

Page 12: termostat Hoval

12 Advanced User Instructions 430294ENG-Jun02 By pressing the key in quick succession the programmed cycles can be called up in series the values noted and corrected if necessary. Time clock level can be exited by pressing the key. Press to enter Cycle program Cycle 1 Monday

ON

Change with Next setting

OFF

Change with Next setting

TEMP (only when set in service level parameters)

Change with Next cycle Cycle 2 Monday

ON

Change with Next setting

OFF

Change with Next setting

TEMP (only when set in service level parameters)

Change with

Next cycle Cycle 3 Monday

ON

Change with Next setting

OFF

Change with Next setting

TEMP (only when set in service level parameters)

Change with Next cycle Remaining days in week Program as Monday

Tuesday ON cycle 1

Sunday OFF cycle 3

Automatic Switch off Time Correction When programming a cycle, if the switch off time is programmed before the switch on time the cycle has no function. Automatic Cycle Sorting If the heating cycles 1 and 3 are programmed and the second cycle is not set (indication 00:00) the second cycle is automatically set to the third cycle values, the third cycle is then made available for further programming.

Page 13: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 13 Skipping Cycles If a called up cycle shows 00:00 the next cycle is skipped. Heating Cycles which overlap midnight If a programmed heating time overlaps midnight e.g. switch on time 6.00pm switch off time 2.00am the cycle must be programmed separately on both days as shown below. Day 1 - Swtch on time 6.00pm switch off time 23.55pm and temperature if enabled. Day 2 - Switch on time 00:00 switch off time 2:00am and temperature if enabled. Time clock program The tables shown on pages 17-19 give an overview of the works programmed standard programs together with temperature settings which cannot be lost. When creating customized programs note the appropriate values in the tables. Canceling of individual heating cycles If necessary individually created cycles can be cancelled. After selecting the required cycle by pressing the key several times the cycle can be cancelled by pressing the and keys simultaneously. Enter the time program Boiler circuit Hot water circuit

Press several times until the desired cycle appears

Press Simultaneously

Cycle cancelled

Restore standard program To restore a customized program to a works standard program select the program as described on page 6 and press the and keys simultaneously. Enter the time program Boiler circuit or Hot water circuit

Press Simultaneously

Standard program restored

Boiler circuit or Hot water circuit Standard program Standard program Restored restored

Time clock level can be exited by pressing the key. The default display will then be restored.

i

Page 14: termostat Hoval

14 Advanced User Instructions 430294ENG-Jun02 Block programming In order to simplify the programming of the time clocks it is possible to copy the time clock settings in various ways. A – Complete automatic programs It is possible to copy complete heating or hot water programs to other programs for example heating program 1 to heating program 3. This can be achieved by using the key to enter the time clock and then the keys to select the heating or hot water as the source. The key is used to select the target program to which it is to be copied. The key is used to complete the copy. The procedure is shown in further detail by the illustration below. Note: It is not possible to copy heating programs to hot water programs or vice versa.

Use or to change program no.

use to enter program to be copied to

Copy will appear

Press key to confirm copy

OK appears to confirm program copied

New source program for further copying

Program will blink

*

* only if present

Source program Source program Boiler circuit program 1 Target program mixer circuit 2 program 2 Program copied Target program = Source program

Copy program 3 from program 1

Copy hot water prog. 3 from hot water prog. 2

Press to enter clock program

Program will blink

Heating circuit

Page 15: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 15 B – Day to day or week Time programs can also be copied from day to the whole week or from day to day for example Tuesday to Wednesday. Day to week While in the time clock see page 13 the key followed by the key can be used to copy the current day to the whole week. The procedure is shown in further detail by the illustration on page 16. Day to day While in the time clock see page 13 the current day can be copied to another day by using the key two or more times to select the target day. The key is used to complete the copy of the current day to the target day. The procedure is shown in further detail by the illustration below.

Enter from heating cycle program Day copying

Day to copy (source day) Week Copying

Press

Target day to Copy to Press to copy Source day copied To target day Target day = Source for next copy

Press again to select target day

Copy again

Day copied to whole week Beginning of week now displayed

Press to copy

Page 16: termostat Hoval

16 Advanced User Instructions 430294ENG-Jun02 Room temperature corrections with individual temperature cycle programs When individual temperatures have been entered for each heating cycle, the desired room temperature can be altered via the correction keys or for one of the cycles. This change will then effect all other heating cycles as shown in the below example: Original cycle temperatures New cycle temperatures As the temperature was increased by 2K during cycle 2 the desired value has been increased by 2K in the other cycles.

Cycle 2 20ºC + 2K = 22ºC

Cycle 1 18ºC + 2K = 20ºC

Cycle 3 22ºC + 2K = 24ºC Etc.

Cycle 2 20ºC

Cycle 1 18ºC

Cycle 3 22ºC

New Cycle 2 22ºC

Room temp + 2K

Page 17: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 17

Program 1 settings

Standard Program 1 - Heating Standard Program 1 - Calorifier

Calorifier temperature - 55oC Day Setting 1 Setting 2 Setting 3 Day Setting 1 Setting 2 Setting 3

From To Temp From To Temp From To Temp From To From To From To

Mon 6.00 8.00 20oC 16.00 22.00 20oC - - - Mon 6.00 8.00 16.00 22.00 - -

Tue 6.00 8.00 20oC 16.00 22.00 20oC - - - Tue 6.00 8.00 16.00 22.00 - -

Wed 6.00 8.00 20oC 16.00 22.00 20oC - - - Wed 6.00 8.00 16.00 22.00 - -

Thur 6.00 8.00 20oC 16.00 22.00 20oC - - - Thur 6.00 8.00 16.00 22.00 - -

Fri 6.00 8.00 20oC 16.00 22.00 20oC - - - Fri 6.00 8.00 16.00 22.00 - -

Sat 7.00 23.00 20oC - - - - - - Sat 6.00 22.00 - - - -

Sun 7.00 23.00 20oC - - - - - -

Sun 6.00 22.00 - - - -

Custom Program 1 - Heating Custom Program 1 - Calorifier

Calorifier temperature - __oC Day Setting 1 Setting 2 Setting 3 Day Setting

1 Setting

2 Setting

3

From To Temp From To Temp From To Temp From To From To From To

Mon Mon

Tue Tue

Wed Wed

Thur Thur

Fri Fri

Sat Sat

Sun

Sun

Page 18: termostat Hoval

18 Advanced User Instructions 430294ENG-Jun02

Program 2 settings

Standard Program 2 - Heating Standard Program 2 - Calorifier

Calorifier temperature - 55oC Day Setting 1 Setting 2 Setting 3 Day Setting 1 Setting 2 Setting 3

From To Temp From To Temp From To Temp From To From To From To

Mon 6.00 22.00 20oC - - - - - - Mon 6.00 22.00 - - - -

Tue 6.00 22.00 20oC - - - - - - Tue 6.00 22.00 - - - -

Wed 6.00 22.00 20oC - - - - - - Wed 6.00 22.00 - - - -

Thur 6.00 22.00 20oC - - - - - - Thur 6.00 22.00 - - - -

Fri 6.00 22.00 20oC - - - - - - Fri 6.00 22.00 - - - -

Sat 6.00 22.00 20oC - - - - - - Sat 6.00 22.00 - - - -

Sun 6.00 22.00 20oC - - - - - -

Sun 6.00 22.00 - - - -

Custom Program 2 - Heating Custom Program 2 - Calorifier

Calorifier temperature - __oC Day Setting 1 Setting 2 Setting 3 Day Setting

1 Setting

2 Setting

3

From To Temp From To Temp From To Temp From To From To From To

Mon Mon

Tue Tue

Wed Wed

Thur Thur

Fri Fri

Sat Sat

Sun

Sun

Page 19: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 19

Program 3 settings

Standard Program 3 - Heating Standard Program 3 - Calorifier

Calorifier temperature - 55oC Day Setting 1 Setting 2 Setting 3 Day Setting 1 Setting 2 Setting 3

From To Temp From To Temp From To Temp From To From To From To

Mon 6.00 23.00 20oC - - - - - - Mon 00.00 23.55 - - - -

Tue 6.00 23.00 20oC - - - - - - Tue 00.00 23.55 - - - -

Wed 6.00 23.00 20oC - - - - - - Wed 00.00 23.55 - - - -

Thur 6.00 23.00 20oC - - - - - - Thur 00.00 23.55 - - - -

Fri 6.00 23.00 20oC - - - - - - Fri 00.00 23.55 - - - -

Sat 6.00 23.00 20oC - - - - - - Sat 00.00 23.55 - - - -

Sun 6.00 22.00 20oC - - - - - -

Sun 00.00 23.55 - - - -

Custom Program 3 - Heating Custom Program 3 - Calorifier

Calorifier temperature - __oC Day Setting 1 Setting 2 Setting 3 Day Setting

1 Setting

2 Setting

3

From To Temp From To Temp From To Temp From To From To From To

Mon Mon

Tue Tue

Wed Wed

Thur Thur

Fri Fri

Sat Sat

Sun

Sun

Page 20: termostat Hoval

20 Advanced User Instructions 430294ENG-Jun02 3 - Room Level At this level, the parameters relevant to the heating requirements of the building and its characteristics can be displayed and changed.

- Hot water temperature - Hot water operation - Burner hours run - Burner starts - Holiday program - Clock programs - Heating curves - Room temperature correction - Reset function

Entering the Room Level Room level can be entered by using the key. Changes can be made using the , and keys. To exit the room level press the key at any time. Press and hold for 3 secs

Hot water temperature

Works setting: 55ºC Adjustment range 10ºC … Hot water maximum temperature press to increase to decrease The maximum temperature is set in the technical parameter level.

Hot water operation

Works setting: On Adjustment range: On or Off Change with keys or On – Hot water control possible Off – No Hot water control

Burner hours run Works setting: 000000.00h

Range: 0 … 99999999

Number of burner starts Works setting:

00000000 Range: 0 … 99999999

Holiday program start

Adjust with to increase and to decrease Change between day and month with and This function is used to switch the heating to frost protection only while the building is unoccupied for example a holiday. The default display will be today’s date.

Holiday program finish

Adjust with to increase and to decrease Change between day and month with and This function is used to switch the heating back on when the building becomes occupied. Example of holiday program

The heating will be switched to frost protection only on the 29.3 at 24.00 hrs

The heating will remain off from 30.3 00.00 hrs to 14.4 00.00 hrs. This will be

the default display until the heating is started again on 14.4.

i

Page 21: termostat Hoval

430294ENG-Jun02 Advanced User Instructions 21 Cancellation of holiday program A complete holiday program can, before commencement be cancelled by pressing

Holiday Begin

or

Holiday end

The and keys simultaneously. The values for holiday start and holiday finish with the exception of holiday set remain for possible reprogramming. Early Cancellation of holiday program An activated holiday program can be cancelled at any time by pressing the or keys and holding until automatic is indicated.

Press or and hold

The default display returns after 4 seconds.

Hot water clock program

Works setting: Program 3 Options: Program 1 Program 2

Program 3 Change with or With this parameter it is possible to change between the three clock programs for hot water, see pages 17 to 19 for settings.

Boiler circuit clock program

Works setting: Program 2 Options: Program 1 Program 2 Program 3 Change with or With this parameter it is possible to change between the three clock programs for the boiler circuit, see pages 17 to 19 for settings.

Heating curve for boiler

Works setting: 1.4 Range: 0.20 … 3.5 Change with or With this parameter it is possible to change the slope of the heating curve for the boiler circuit (see graph). The heating curve gives the boiler flow temperature / outdoor temperature ratio. The curve should only be reset with minimum changes spread out over a certain period of time to enable the regulator to react (by nature a heating installation is very slow to react). Corrections of 0.1 increments every 1 or 2 days is recommended.

Blinks if auto adaption is set in service level parameters (do not change)

Page 22: termostat Hoval

22 Advanced User Instructions 430294ENG-Jun02 Note: The room station should be placed in the room that most accurately represents the temperature of the building. Thermostatic radiator valves when fitted properly should only serve to deregulate foreign heat sources and therefore should be fully open. During the regulation phase all foreign heat source should be switch off and ventilation should be kept to a minimum so as not to disturb the regulation process. When the heating curve is correctly set the room temperature should remain constant regardless of outside temperature. If automatic adaption is set in the service level the value will blink and is constantly corrected. In this case it must not be manually altered. Recommended values: Floor heating: 0.3 ….. 1.0 Radiator heating: 1.2 ….. 2.0 Convection heating: 1.5 ….. 2.0 Heating curve graph

Room temperature compensation

1 2 Works setting: 0.0K Range: -2.5K … +2.5K Change with or 1 – Room temperature 2 – Correction With this parameter it is possible to calibration the room temperature by ± 2.5K.

Reset function

With this function it is possible to reset all the room level parameters back to their factory settings with the exception of burner hours run and burner starts. To reset room level parameters hold and Simultaneously until the following display appears

Parameters reset

Default screen

Max 80ºC

Min 31ºC

Outside temperature ºC

Boiler Flow Temp ºC

Page 23: termostat Hoval

430294ENG-Jun02 Room Level Parameters 23

Parameter Function Range Factory Setting Current Setting

1. Hot water temp 10oC – Max setting

55oC

2. Hot water operation Off, On On

3. Burner hours run 000000.00 – 999999.59

000000.00

4. Burner starts 00000000 – 99999999

00000000

5. Holiday program start 01/01 – 31/12 Not set

6. Holiday program finish 01/01 – 31/12 Not set

7. Clock program for Hot water 1 – 2 – 3

2

8. Clock program for Heating 1 – 2 – 3

2

9. Heating curve 0.20…3.50 1.4

10. Room temperature compensation

-2.5 … +2.5K

11. Reset Reset to factory settings

Page 24: termostat Hoval

24 Advanced Parameter Table 430294ENG-Jun02

Parameter Function Parameter Function Range Factory

Setting Current Setting

1 First Commissioning date - -

2 Room Sensor Off - On Off

3 Influence of room temp 0…250% 50%

4 Auto Adaption Off - On On

5 Variable room temp Off - On Off

6 Derivative action time 0…6 h 2 h

7 Heating maximum temp 40…90oC 80oC

8 Hot water maximum temp 40…60oC 60oC

9 Frost protection -20…+10oC 0oC

10 Summer switch off +10…30oC 17oC

11 Protection against Legionella Off 1…8 Off

12 Night water load 10…100% 30%

13 Summer/Winter switchover On – Off On

14 Heating user index 1.0 / 1.31 / 2.0 2P5K, 2P10K 1.31

15 Minimum outdoor temperature -20…0oC -10 oC

16 Type of calorifier sensor 1, 2 1 (Thermostat)

17 Room level lock up 0, 1, 2 0

18 Alarm Logic signals On – Off On

RESET - -

Page 25: termostat Hoval

430293ENG-Dec01 Installation / Technical Data 25

Installation

Positioning – without room sensor If there is no room sensor or the room sensor has not been activated the unit can be placed as desired.

Positioning – with room sensor When used with the unit sensor activated the unit must be placed at a height of approximately 1.20 to 1.50 m in a place representing the temperature of all rooms. It is advisable to choose an internal wall in the coolest room which is used in the day.

The unit may not be positioned: �� In direct sunlight (take note of the position of the sun in winter) �� Near any equipment which produces heat like televisions, wall lights, radiators etc. �� On walls where hot water pipes or chimneys run. �� On outside walls which are not insulated. �� In corners, recesses, shelves or behind curtains (insufficient air circulation). �� Near doors which lead to unheated rooms. �� In rooms which are regulated with thermostatic valves.

Mounting Open the cover and loosen the screw inside. Lift the unit off the back plate. Secure the back plate with the screws provided. The data bus cable must be threaded through the lower part of the back plate. With a data bus cable of over 50m cable of types JY-(ST) 2x0.6 must be used. The screening must be connected to the earth terminal of the boiler. Note: on new installations use a box behind the room station.

Electrical Connection Before connecting / wiring the power at the boiler must be off. The 2 core bus cable is connected to the 4 pole terminal on the back plate. After the wiring is complete the room station is slotted in from above and screwed to the back plate. Refer to the electrical diagram supplied with the boiler. Note: by incorrect wiring the remains in VERSION indication for approximately 1 minute and then goes to fault indication. Technical Data

Wiring: 4 pole screwed terminals on back plate for 1mm2 max wire cross section.

Bus Interface: RS485

Power supply: From central unit

Color: White RAL 9016

Fixing distance: 60mm (2 hole fixing) Wall Fixing: 2 x 3mm dia x 18 long

Weight: 170g

Operating Temperature: -10oC….+50oC

Storage Temperature: -25oC….+60oC

Clock Accuracy: - +/- 50sec./month

Data retention: - Backup for 5 years

Indication: Alpha numeric text indication as well as symbols


Recommended