+ All Categories
Home > Food > TESSOL's PlugNchill Refrigeration

TESSOL's PlugNchill Refrigeration

Date post: 29-Jul-2015
Category:
Upload: rajat-gupta
View: 300 times
Download: 0 times
Share this document with a friend
Popular Tags:
16
Thermal Energy Service Solutions Pvt. Ltd. PLUGnCHILL FUEL-FREE REEFER SYSTEMS Smit Shah +91-9167837024 [email protected] © Thermal Energy Service Solutions Pvt. Ltd.
Transcript

Thermal Energy Service Solutions

Pvt. Ltd.

PLUGnCHILL FUEL-FREE REEFER SYSTEMS

Smit Shah

+91-9167837024

[email protected]© Thermal Energy Service Solutions Pvt. Ltd.

HOW PLUGnCHILL TRANSPORT WORKS?

PLUG IN REEFER FOR 4-6 FREEZES THERMAL

TESSOL patented system

enables charging in 5-6

hours

1/19/2015 © Thermal Energy Service Solutions Pvt. Ltd.

PLUG IN REEFER FOR 4-6

HOURS TO GRID POWER

LOADING AND DELIVERING

ZERO FUEL CONSUMPTION

DURING TRAVEL

FREEZES THERMAL

STORAGE SYSTEM

TESSOL design ensures

faster temperature pull

down after each delivery

BACK TO LOADING STATION

TECHNOLOGY BACKGROUND

-45

-35

-25

-156

:28

:49

6:3

6:2

9

6:4

3:5

9

6:5

1:2

9

6:5

9:1

0

7:0

6:4

0

7:1

4:1

0

7:2

1:4

0

7:2

9:1

0

7:3

6:5

0

7:4

4:2

0

7:5

1:5

0

7:5

9:2

0

8:0

6:5

1

8:1

4:2

1

8:2

1:5

1

8:2

9:2

1

8:3

6:5

1

8:4

4:2

2

8:5

1:5

2

8:5

9:2

2

9:0

6:5

3

9:1

4:3

4

9:2

2:0

4

9:2

9:3

4

9:3

9:1

5

9:4

6:5

5

9:5

4:3

5

10

:02

:15

10

:11

:49

10

:19

:41

10

:27

:12

10

:34

:42

10

:42

:32

10

:50

:02

10

:57

:32

11

:05

:13

11

:12

:43

11

:20

:13

11

:27

:43

11

:35

:13

Tem

pe

ratu

re (

oC

)

Time

FREEZING MELTING GRAPH OF A PHASE CHANGE MATERIAL

MELTING DURING TRAVEL FREEZING DURING CHARGING

10

:02

:15

10

:11

:49

10

:19

:41

10

:27

:12

10

:34

:42

10

:42

:32

10

:50

:02

10

:57

:32

11

:05

:13

11

:12

:43

11

:20

:13

11

:27

:43

11

:35

:13

PCM DRIVNG TEMPERATURE

HEAT EXCHANGER PLATE

WITH PCM AND COILS

CHARGING USING

REFRIGERANT

FROZEN PLATE STORES

LATENT ENERGY

KEY ADVANTAGES OVER REEFER

© Thermal Energy Service Solutions Pvt. Ltd.

PRODUCT VARIANTS

SYSTEM VARIANTS

STATIONARY CHARGING UNIT VEHICLE MOUNTED UNIT

REDUCED CAPEX

HIGH REDUNDANCY

REDUCED WEIGHT

OPERATIONAL EASE

HIGH FLEXIBILITY

LESS SPACE USAGE

CONTAINER SIZE DESCRIPTION SMALL

(8 FEET)

MEDIUM

(15 FEET)

LARGE

(24FEET)

PLUGnCHILL

SYSTEM

Total power consumption

per day (kWh)

10 21 31

Power cost (Rs./kWh) 9 9 9

Usage days / year 300 300 300

Total cost 27,000 56,700 83,700

CONVENTIONAL Diesel consumption 0.8 1.5 1.9

COST BENEFIT ANALYSIS

CONVENTIONAL

SYTEM

Diesel consumption

(Liters/hour)

0.8 1.5 1.9

Compressor run (hrs/day) 7 7 7

Diesel price (Rs./liter) 61 61 61

Usage days/year 300 300 300

COST BENEFIT

ANALYSIS

Total cost 1,02,480 1,92,150 2,43,390

Profit in INR 75,480 1,35,450 1,59,690

Profit in % 73.6% 70.4% 65%

© Thermal Energy Service Solutions Pvt. Ltd.

OUR ESTEEMED CLIENTS

8

CUSTOMER TESTIMONIAL

Description Details

Charging time 6 hrs

Room Temp -4 C

Power Consumption 13 kwh

Travel Time 9 hrs

Number of deliveries 6

Total Door Opening Period 85 min

CASE STUDY – LEADING BAKERY SHOP

Total Door Opening Period 85 min

Field Trial was carried out at high ambient temperature in mid-summer

Customer does the field trial for their longest delivery route i.e. 350 kms

Much longer duration of door opening than normal

© Thermal Energy Service Solutions Pvt. Ltd.

FIELD TRIAL – BAKERY RESULTS

6

8

10

12

14Charging Discharging

Delivery starts 1st delivery

Unloading

TE

MP

ER

AT

UR

E I

N o

C

-4

-2

0

2

4

6

23

:59

:19

0:1

8:1

9

0:3

7:1

9

0:5

6:1

9

1:1

5:1

9

1:3

4:1

9

1:5

3:1

9

2:1

2:1

9

2:3

1:1

9

2:5

0:1

9

3:0

9:1

9

3:2

8:1

9

3:4

7:1

9

4:0

6:1

9

4:2

5:1

9

4:4

4:1

9

5:0

3:1

9

5:2

2:1

9

5:4

1:1

9

6:0

0:1

9

6:1

9:1

9

6:3

8:1

9

6:5

7:1

9

7:1

6:1

9

7:3

5:1

9

7:5

4:1

9

8:1

3:1

9

8:3

2:1

9

8:5

1:1

9

9:1

0:1

9

9:2

9:1

9

9:4

8:1

9

10

:07

:19

10

:26

:19

10

:45

:19

11

:04

:19

11

:23

:19

11

:42

:19

12

:01

:19

12

:20

:19

12

:39

:19

12

:58

:19

13

:17

:19

13

:36

:19

13

:55

:19

14

:14

:19

14

:33

:19

14

:52

:19

15

:11

:19

Loading

© Thermal Energy Service Solutions Pvt. Ltd.

TIME

TE

MP

ER

AT

UR

E I

N

Description Details

Charging time 5

Room Temp -4oC

Power Consumption 9 kwh

Delivery Time 7.5 hrs

Total Door Opening Period 65 min

Total Deliveries 6

CASE STUDY – POULTRY PRODUCTS

Total Deliveries 6

The system showed a faster pull down time after each door opening

Chicken temperature while loading was 4.5 C which was lower down to

2.5 C at the last delivery point.

Loading and delivery starts after 2 hours of system charge which shows the

ease of using the system at your convenient time even after charging.

© Thermal Energy Service Solutions Pvt. Ltd.

5

7

9

11

13

15

17

19 DISCHARGINGCHARGING

Loading

first delivery Last delivery

Empty

crates

Unloading

FIELD TRIAL – POULTRY RESULTS T

EM

PE

RA

TU

RE

IN

oC

-11

-9

-7

-5

-3

-1

1

3

5

0:0

0:0

0

1:1

2:0

0

2:2

4:0

0

3:3

6:0

0

4:4

8:0

0

6:0

0:0

0

7:1

2:0

0

8:2

4:0

0

9:3

6:0

0

10

:48

:00

12

:00

:00

13

:12

:00

14

:24

:00

© Thermal Energy Service Solutions Pvt. Ltd.

TE

MP

ER

AT

UR

E I

N

TIME

TESSOL SUMMARY

• Customized and specialized systems

• Process Cooling and HVACPROJECTS

TESSOL creates products and solutions using “Thermal Energy

Storage” technology for specific applications

• Stationary and Mobile Cold Storage (Electric transport)

COLD STORAGE

• Energy Efficient HVAC Systems

• Commercial and Industrial marketsHVAC

1/19/2015 © Thermal Energy Service Solutions Pvt. Ltd.

LEADERSHIP @ TESSOL

Rajat Gupta – Founder CEO

• Leads operations, technology and sales for TESSOL

• 10+ years operations experience in startup and MNC , 5 years in Energy / cold chain space

• Business Head – Energy Project Division, Bosch Rexroth India

• COO at Promethean Power Systems Pvt. Ltd doing renewable and energy storage based decentralized milk chillers

• B.Tech Mech. IITD, MBA Harvard Business School, Worked in US, EU and India

1/19/2015

• B.Tech Mech. IITD, MBA Harvard Business School, Worked in US, EU and India

© Thermal Energy Service Solutions Pvt. Ltd.

Rustom Irani - Director

•Investor and advisor at TESSOL

•Founder CEO at Icelings pvt. Limited, largest Ice machine manufacturers in India , VP M&T Bank USA

•Industry vetran with 20+ years in cold chain space. Multiple assets in seafood industry, cold chain, wind mills and other renewables

•BA University of Oklahoma, MBA Cornell Johnson School

CORE TEAM @ TESSOLDr. Goraksh Takalkar – Product Manager

• Leads development, analysis and prototyping at TESSOL

• R&D expertise in vapor absorption, compression, heat pumps

• Bry air award winner, PhD in Chemical engineering from ICT Mumbai

Glen Fonseca – Service Lead

• Leads service, installation and field operations at TESSOL

• Relevant experience >15 years in installing and servicing HVAC systems, Work experience in Middle east, Africa and India

Smit Shah – Sales Manager Cold Chain

• SIIB 2014 graduate in Agri business management

• 3 years experience in Pharma Sales (Zydus Cadila) as Zonal sales head, Reliance Fresh (intern)

Suresh Nikumbh – Operations Manager

• 20+ years experience in production and R&D with leading refrigeration companies

• Previous experience with Voltas, Prijai Heat Exchangers .

© Thermal Energy Service Solutions Pvt. Ltd.

REACH US

+91-9167837024

[email protected]

Thermal Energy Service Solutions Pvt Ltd

R-389,T.T.C Industrial Area, Rabale, Navi Mumbai -R-389,T.T.C Industrial Area, Rabale, Navi Mumbai -

400701

© Thermal Energy Service Solutions Pvt. Ltd.


Recommended