Test Report Report Number: L19021 Date: Apr 10, 2019 Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test of one High Bay Unit manufacturer: Dialight Corporation Unit model number: RRE-4MC2-Gxxx-xxN Issued to: Dialight Corporation 1501 Route 34 South, Farmingdale, NJ 07727 Tests performed: Dates of test: April 9, 2019 through April 10, 2019 Standards used: Description of sample: Sample Number: L19021 Manufacturer: Dialight Corporation Product Name: Reliant High Bay Description: High Bay Model Number: RRE-4MC2-Gxxx-xxN Photometric characterization and temperature measurement per the described standards. All tests are performed in accordance with procedures and guidelines prescribed by the American National Standards Institute (ANSI) or Illuminating Engineering Society of North America (IES): • IES LM-79:2008: Electrical and Photometric Measurements of Solid-State Lighting Products • ANSI/UL 1598:2008: Underwriters Laboratories Inc. Standard for Safety: Luminaires • ENERGY STAR Manufacturer's Guide for Qualifying Solid State Lighting Luminaires Version 2.1 Dialight Optics Laboratory Report Number: L19021 Page 1 of 9
Transcript
Page 1: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Report

Report Number: L19021 Date: Apr 10, 2019

Issued by:

Dialight Optics Laboratory

1501 Route 34 South, Farmingdale, NJ 07727

Test of one High Bay

Unit manufacturer: Dialight Corporation

Unit model number: RRE-4MC2-Gxxx-xxN

Issued to:

Dialight Corporation

1501 Route 34 South, Farmingdale, NJ 07727

Tests performed:

Dates of test: April 9, 2019 through April 10, 2019

Standards used:

Description of sample:

Sample Number: L19021

Manufacturer: Dialight Corporation

Product Name: Reliant High Bay

Description: High Bay

Model Number: RRE-4MC2-Gxxx-xxN

Photometric characterization and temperature measurement per the described

standards.

All tests are performed in accordance with procedures and guidelines prescribed by

the American National Standards Institute (ANSI) or Illuminating Engineering Society

of North America (IES):

• IES LM-79:2008: Electrical and Photometric Measurements of Solid-State Lighting Products

• ANSI/UL 1598:2008: Underwriters Laboratories Inc. Standard for Safety: Luminaires

• ENERGY STAR Manufacturer's Guide for Qualifying Solid State Lighting Luminaires Version 2.1

Dialight Optics Laboratory

Report Number: L19021 Page 1 of 9

Page 2: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Report SummarySample number L19021

Dialight unit model number RRE-4MC2-Gxxx-xxN

Photograph(s) of sample:

*Photographs not to scale. For reference only.

Summary of Results:

Integrating Sphere Goniophotometer

Luminous Flux: (lumens) (lumens)

Electrical Power: (W) (W)

Luminous Efficacy: (lumens/W) (lumens/W)

Electrical Measurements:

Input Power (230VAC): (W)

Power Factor (230VAC):

Current ATHD % (230VAC):

Input Power (110VAC): (W)

Power Factor (110VAC):

Current ATHD % (110VAC):

Color Measurements:

Correlated Color Temperature (CCT):

Color Rendering Index (CRI):

Chromaticity Coordinate (x):

Chromaticity Coordinate (y):

Chromaticity Coordinate (u'):

Chromaticity Coordinate (v'):

DUV:

Temperature Measurements:

In Situ LED Source Temperature: (°C)

146.6

0.997

0.985

5034

4.083

9.156

0.21

0.324

55.7

0.345

0.354

0.0016

28150

192.0

28379

192.0

147.8

86.5

192.0

199.3

Dialight Optics Laboratory

Report Number: L19021 Page 2 of 9

Page 3: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: Integrating Sphere

Results include unit color, flux, efficacy and electrical power for sample number L19021.

Dialight unit model number RRE-4MC2-Gxxx-xxN

Test Conditions:

Ambient Temperature: (°C)

Electrical Measurements:

Input Voltage: (VAC)

Input Current: (A)

Input Power: (W)

Input Power Factor:

Current ATHD: (%)

Photometric measurements:

Luminous Flux: (lumens)

Luminous Efficacy: (lumens/W)

Correlated Color Temperature (CCT): (K)

CRI -Ra:

CRI -R9:

DUV:

CIE Coordinate (x):

CIE Coordinate (y):

CIE Coordinate (u'):

CIE Coordinate (v'):

23.1

0.345

0.354

0.21

25 ± 1

0.324

0.0016

28150

146.6

5034

86.5

230

0.845

192.0

0.985

9.156

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

350 400 450 500 550 600 650 700 750 800

Sp

ectr

al

Po

wer

(W)

λ (nanometers)

Spectral Power in Visible Range

Dialight Optics Laboratory

Report Number: L19021 Page 3 of 9

Page 4: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: Integrating SphereResults continued from previous page.

Tabulated Spectral Power in Visible Range:

385

515

520

525 0.387

390 670

395

400

0.899

535 0.917

0.943

λ(nm)

655

660

665

680

375

380

0.824

0.849

0.492

0.437

(W/nm) λ(nm)

475

480

435

440

445

450

455

410

415

420

425

430

510

λ(nm)

0.012

0.016

0.015

0.014

0.015

0.017

0.022

0.031

0.048

0.081

0.137

0.235

0.393

0.644

485

490

495

500

505

460

465

470

0.7350.786

615

630

645

0.582

0.456

0.421

0.454

0.511

0.587

0.666

1.099

1.563

1.426

0.963

0.733

1.000

560 1.014

555

570

585

600

1.033

575 1.040

580 1.044

0.667

0.934

620 0.890

625 0.838

1.044

590 1.042

595 1.035

725

740

0.197

700

0.069

0.342

675 0.299

0.170

0.044

(W/nm) (W/nm)

0.018

775 0.016

780 0.014

0.028

760 0.024

765 0.021

0.606650 0.548

755

7700.785

0.147

705 0.127

0.260

685 0.227

690

565 1.024

695

545 0.963

550 0.984

405

540

0.875

530

0.059

735 0.051

0.109

715 0.094

720 0.080

745 0.037

750 0.032

730

1.021

605 1.000

610 0.972

635 0.727

640

710

Dialight Optics Laboratory

Report Number: L19021 Page 4 of 9

Page 5: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: GoniometerResults include unit flux, distribution, efficacy, and electrical power for sample number L19021.

Dialight unit model number RRE-4MC2-Gxxx-xxN

Electrical Measurements:

Input Voltage: (VAC)

Input current: (A)

Input Power: (W)

Power Factor:

Photometric measurements:

Absolute Luminous Flux: (lumens)

Luminous Efficacy: (lumens/W)

Intensity Summary:

INTENSITY (CANDLEPOWER) SUMMARY

ANGLE ALONG

ZONAL LUMEN AND PERCENTAGES

230

0.848

192.0

0.986

147.8

28379

105

115

125

135

145

155

165

0

5

15

25

35

45

55

65

75

175

180

10734

10709

10757

11421

11576

8857

4511

724

120

38

0

0

0

0

0

0

0

0

0

0

85

95

23

10734

10709

10757

11421

11576

8857

4511

724

120

38

0

0

0

0

0

0

0

0

0

0

45

10734

10709

10757

11421

11576

8857

4511

724

120

38

0

0

0

0

0

0

0

0

0

0

67.5

10734

10709

10757

11421

11576

8857

4511

724

0

0

0

120

38

0

0

0

0

0

0

0

0

0

0

0

0

0

ACROSS

10734

10709

10757

11421

11576

8857

4511

724

120

38

0

0

0

0

0

0

0

259

68

7

0

0

0

0

0

0

OUTPUT LUMENS

400

2289

4426

6642

7244

5292

1752

% LUMINAIRE

36.0%

61.6%

97.1%

4.7%

100.0%

0.0%

100.0%

ZONE

0-30

0-40

0-60

60-90

0-90

90-180

0-180

LUMENS

10202.88

17479.84

27559.36

1327.84

28379.2

0

28379.2

Dialight Optics Laboratory

Report Number: L19021 Page 5 of 9

Page 6: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: GoniometerResults continued from previous page.

Polar Plot:

Dialight Optics Laboratory

Report Number: L19021 Page 6 of 9

Page 7: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: GoniometerResults continued from previous page.

Illuminance Plot:

Illuminance-Cone of Light:

Dialight Optics Laboratory

Report Number: L19021 Page 7 of 9

Page 8: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Test Results: In Situ Temperature Measurement TestResults include maximum LED chip temperature for sample number L19021.

Dialight unit model number RRE-4MC2-Gxxx-xxN

LED identified as Seoul Semiconductor part number SAW8C22B.

LED drive current (as indicated by customer): (mA)

LED Specifications:

LED specifications are taken from LED manufacturer datasheet:

Maximum Forward Current (If): (mA)

Maximum Rated Power Dissipation: (W)

Maximum Junction Temp. (Tj): (°C)

Thermal Resistance (Rth): (°C/W)

Derived Specifications:

Maximum Power at Indicated Current: (W)

Maximum Source Temperature: (°C)

Test Conditions:

Temperature Measurement Location: See Photographs Below

Ambient Temperature: (°C)

Ambient temperature at time of measurement: (°C)

Relative humidity at time of measurement:

Results:

Measured LED source temperature: (°C)

29

1.5

125

17

250

0.174

31%

55.7

24

25° ± 5°

122

Dialight Optics Laboratory

Report Number: L19021 Page 8 of 9

Page 9: Test Report - Dialight · 10757 11421 11576 8857 4511 724 120 38 0 0 0 0 0 0 0 0 0 0 67.5 10734 10709 10757 11421 11576 8857 4511 724 0 0 0 120 38 0 0 0 0 0 0 0 0 0 0 0 0 0 across

Equipment Used:

Equipment Name Model Number

Additional Notes:

Samples are received and tested in new and undamaged condition, unless otherwise noted.

Test Report Issued By: Test Report Reviewed and Approved By:

Volttech Power Analyzer

Volttech Universal Breakout Box

1715A

PM1000+

PM1000+

971

068158

Xitron Power Analyzer XT2640

Osram Sylvania Calibration Lamp for Sphere STD-20WF-3

GwINSTEK DC Power Supply GEP172679

This report shall not be reproduced, except in full, without the express written permission of

Dialight Optics Laboratory.

ITL Osram Calibraton lamps for Goniometer

ITL Osram Calibraton lamps for Goniometer

Adaptive Power Systems AC Power Supply

U1273A

J9a8

J9a8

J9a8

FC-210

Dpi8-C24

Agilent True RMS OLED Multimeter

The results shown in this report are representative only of the test samples submitted. This data

has been issued to the assignee for further evaluation.

ITL Osram Calibraton lamps for Goniometer

This report shall not be used by the client to claim product certification, approval, or endorsement

by NVLAP, NIST, or any agency of the Federal Government.

Instrument System 1.5 Meter Sphere

Delta Elektronika DC Power Supply

Instek AC Power Supply

Sorensen DC Power Supply

TPI Digital Thermometer

Fluke 52II Thermometer

Fluke 971 Humidity Meter

Dpi8

TPI 343

XHR150-7

APS-9501

SM.300-5

ISP1500

CAS140B-151

6240T

11/26/3981

LSI High Speed Mirror Goniometer

Instrument System Spectrometer

Omega TC

Fluke 8808A Digit Multimeter

YOKOGAWA Digital Power Meter

8808A

BK Precison

Step-Up Transformer

Omega TC

Richard Huegi

Dialight Optics Laboratory

Senior Optical Engineering Technician

Lighting Division

Vishnu Shastry

Dialight Optics Laboratory

Optical Engineer

Approved Signatory

Dialight Optics Laboratory

Report Number: L19021 Page 9 of 9