+ All Categories
Home > Documents > Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This...

Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This...

Date post: 29-Jul-2021
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
147
Königswinkel 10 32825 Blomberg Phone +49 5235 / 9500-0 Fax +49 5235 / 9500-10 Test Report No: U144305E1, 2 nd Version Designation of equipment under test: KVM Matrix switch system - DVICenter DP32 - U2-R-CPU - U2-R-CON - DVI-U-CPU-MC2-UC - DVI-U-CON-MC4 - MultiPower 12 - MultiPower 6 - PowerSet12 Typ 3 SinPro SPU25A-105 - PowerSet12 Typ 2 SinPro SPU25A-105 Test Laboratory for "Safety of Electrical Equipment and Industrial Low-Voltage Devices as well as Environmental Tests" accredited by DAkkS Deutsche Akkreditierungsstelle GmbH in compliance with DIN EN ISO/IEC 17025 under Reg. No. D-PL-17186-01-03
Transcript
Page 1: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Königswinkel 1032825 BlombergPhone +49 5235 / 9500-0Fax +49 5235 / 9500-10

Test ReportNo: U144305E1, 2nd Version

Designation of equipment under test: KVM Matrix switch system

- DVICenter DP32- U2-R-CPU- U2-R-CON- DVI-U-CPU-MC2-UC- DVI-U-CON-MC4

- MultiPower 12 - MultiPower 6 - PowerSet12 Typ 3 SinPro SPU25A-105

- PowerSet12 Typ 2 SinPro SPU25A-105

Test Laboratory

for"Safety of Electrical Equipment and

Industrial Low-Voltage Devicesas well as Environmental Tests"

accredited byDAkkS Deutsche Akkreditierungsstelle GmbH

in compliance with DIN EN ISO/IEC 17025under

Reg. No. D-PL-17186-01-03

Page 2: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 2 of 147

The copying of excerpts from this report is not permitted without written the consent of the testing body.The test results indicated in this report refer exclusively to the equipment under test specified below. It isnot permitted to transfer the results to other systems or configurations.

Testing body: PHOENIX TESTLAB GmbHKönigswinkel 10

D-32825 Blomberg

Applicant: Guntermann & Drunck GmbHDortmunder Str. 4a

D-57234 Wilnsdorf

Order number: 14-114305

Type of test: Environmental test:

- Vibration, sinusoidal- Dry heat, storage- Dry heat, functional test- Cold, functional test- Damp heat, functional test- Exceptional power supply

Test base: EN 60068-2-1 : 2008EN 60068-2-2 : 2008EN 60068-2-6 : 2008EN 60068-2-30 : 2005IEC 60945 : 2002

Page 3: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 3 of 147

Equipmentunder test: KVM Matrix switch system

EUT Type S.N. Art. Nr.

144305 – A DVICenter DP32 GD03097064 A2300035

144305 – B U2-R-CPU GD03097062 A2320063144305 – C U2-R-CON GD03097063 A1120151

144305 – D DVI-U-CPU-MC2-UC GD03097061 A2320111

144305 – E DVI-U-CON-MC4 GD03097060 A1120178144305 – F MultiPower 12 GD08001985 A4110036144305 – G MultiPower 6 GD08001984 A4110035

144305 - H PowerSet12 Typ 3SinPro SPU25A-105 C36769651344 A4110013

144305 - W PowerSet12 Typ 2SinPro SPU63-105 C33088081246 A4110008

Manufacturer: See applicant

Date equipmentwas received: 20 August 2014

Test specifications: EN 60068-2-1 : 2008EN 60068-2-2 : 2008EN 60068-2-6 : 2008EN 60068-2-30 : 2005IEC 60945 : 2002

Customer representedduring the test by thefollowing person(s): ---

Place of testing: PHOENIX TESTLAB GmbH, Blomberg

Date of testing: 21 August 2014 to 17 September 2014

Page 4: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 4 of 147

Test result: Test requirements and conditions are present in the followingchapters.

The requirements made in the test documents were fulfilled bythe equipment under test.

Blomberg, 03 November 2014

Testengineer: Frank Nothnagel Authorized reviewer: Michael Jonca

Page 5: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 5 of 147

Contents Page

1 Test specifications and test conditions ......................................................................... 6

1.1 Dry heat, storage ................................................................................................... 6

1.2 Dry heat, functional test ......................................................................................... 7

1.3 Cold, low temperature functional test..................................................................... 8

1.4 Damp heat, functional test ..................................................................................... 9

1.5 Vibration ............................................................................................................... 10

1.6 Excessive power supply ....................................................................................... 12

1.7 Operating states and test set-up .......................................................................... 13

1.8 Monitoring of the EUT during the Test ................................................................. 21

2 Test performance and test results .............................................................................. 27

2.1 Test performance ................................................................................................. 27

2.2 Test results .......................................................................................................... 28

2.2.1 Resonance search ......................................................................................... 28

2.2.2 Vibration, sinusoidal ....................................................................................... 34

2.2.3 Dry heat, storage test ..................................................................................... 37

2.2.4 Dry heat, Functional test ................................................................................ 37

2.2.5 Cold, Low temperature Functional test .......................................................... 38

2.2.6 Damp heat, Functional test ............................................................................ 38

2.2.7 Excessive power supply ................................................................................. 39

3 List of measurement equipment ................................................................................. 40

4 Pictures ...................................................................................................................... 41

5 List of pictures .......................................................................................................... 143

6 List of Diagrams........................................................................................................ 145

Page 6: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 6 of 147

1 Test specifications and test conditions

1.1 Dry heat, storage

Test B: Dry heat / EN 60068-2-2; chapter 8.2.1, IEC 60945

To simulate the effects of temperature stress on equipment in the non-operating

(un-powered) mode. A temperature of +70 °C is the maximum likely to be

encountered in enclosed spaces on ships and in equipment exposed to the full

effects of solar radiation in ports.

The EUT shall be placed in a chamber at normal room temperature and relative

humidity. The temperature shall then be raised to and maintained at 70 °C ± 3 °C,

for a period of 10 h to 16 h.

At the end of the test, the EUT shall be returned to normal environmental condi-

tions and then subjected to a performance check as specified in the relevant

equipment standard (see 7.1; IEC 60945).

Test Severity

Temperature +70 °C ± 3 °C

Duration 16 hours

Voltage during performance check

U = 90 V / 264 V ; f = 47.5 Hz / 63 Hz(Extreme power supply variation)Nominal voltage range 100 V … 240 VVoltage variation ± 10 %Frequency variation ± 5 %

Page 7: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 7 of 147

1.2 Dry heat, functional test

Test B: Dry heat / EN 60068-2-2; chapter 8.2.2, IEC 60945

This test determines the ability of equipment to be operated at high ambient tem-

peratures and operate through temperature changes. The reasonable maximum

air temperature likely to be encountered over the sea is +32 °C and the maximum

solar gain at sea is +23 °C giving +55 °C as the maximum temperature likely to be

encountered by ships at sea.

The EUT shall be placed in a test chamber at room temperature. The EUT and, if

appropriate, any climatic control devices with which it is provided shall then be

switched on. The temperature shall then be raised to and maintained at +55 °C ±

3 °C.

At the end of a soak period of 10 to 16 hours at +55 °C ± 3 °C, the EUT shall be

subjected to a performance test and check as specified in the relevant equipment

standard (see 7.1).

The temperature of the chamber shall be maintained at +55 °C ± 3 °C during the

whole performance test period.

At the end of the test, the EUT shall be returned to normal environmental condi-

tions.

Test Severity

Temperature + 55 °C ± 3 °C

Duration 16 hours

Voltage during performance test U = 100 V / 240 V; f = 50 Hz / 60 Hz(Normal power supply)

Voltage during performance check

U = 90 V / 264 V ; f = 47.5 Hz / 63 Hz(Extreme power supply variation)Nominal voltage range 100 V … 240 VVoltage variation ± 10 %Frequency variation ± 5 %

Page 8: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 8 of 147

1.3 Cold, low temperature functional test

Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945

This test determines the ability of equipment to be operated at low temperatures

and also to demonstrate the ability of equipment to start up a low ambient temper-

ature.

The EUT shall be placed in a test chamber at room temperature. The temperature

shall then be reduced to, and maintained at -15 °C ± 3 °C, for a period of 10 h to

16 h. Any climatic control devices provided in the EUT may be switched on at the

conclusion of this period.

The EUT shall be switched on 30 minutes later, or after such a period as agreed

by the manufacturer, and shall be kept operational for at least 2 h during which

period the EUT shall be subjected to a performance test and check as specified in

the relative equipment standard (see 7.1).

The temperature of the chamber shall be maintained at - 15 °C ± 3 °C during the

whole test period.

At the end of the test the EUT shall be returned to normal environmental condi-

tions.

Test Severity

Temperature -15 °C ± 3 °C

Duration 16 hours

Voltage during performance test U = 100 V / 240 V; f = 50 Hz / 60 Hz(Normal power supply)

Voltage during performance check

U = 90 V / 264 V ; f = 47.5 Hz / 63 Hz(Extreme power supply variation)Nominal voltage range 100 V … 240 VVoltage variation ± 10 %Frequency variation ± 5 %

Page 9: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 9 of 147

1.4 Damp heat, functional test

Test Db: Damp heat / EN 60068-2-30; chapter 8.3, IEC 60945

This test determines the ability of equipment to be operated under conditions of

high humidity.

The EUT shall be placed in a test chamber at room temperature. The temperature

shall then be raised to + 40 °C ± 2 °C, and the relative humidity raised to 93 % ±

3 % over a period of 3 h ± 0.5 h. These conditions shall

be maintained for a period of 10 h to 16 h. Any climatic control devices provided in

the EUT may be switched on at the conclusion of this period.

The EUT shall be switched on 30 minutes later, or after such a period as agreed

by the manufacturer, and shall be kept operational for at least 2 h during which

period the EUT shall be subjected to a performance check as specified in the rel-

evant equipment standards.

The temperature and relative humidity of the chamber shall be maintained as

specified during the whole test period.

At the end of the test period and with the EUT still in the chamber, the chamber

shall be brought to room temperature in not less than 1 h.

At the end of the test the EUT shall be returned to normal environmental condi-

tions.

Test Severity

Temperature + 40 °C ± 2 °C

Relative humidity 93 % ± 3 %

Duration 16 hours (1 cycle)

Voltage during performance check U = 100 V / 240 V; f = 50 Hz / 60 Hz(Normal power supply)

Page 10: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 10 of 147

1.5 Vibration

Test Fc: Vibration, sinusoidal / EN 60068-2-6

This test determines the ability of equipment to withstand vibration without re-

sulting in mechanical weakness or degradation in performance.

The test simulates the effect of vibration induced in a ship's hull by its propeller

and machinery. This is generally at frequencies of up to 13 Hz and predominant-

ly vertical.

The tests at higher frequencies simulate the effect of slamming which occurs in

irregular stormy seas, and is predominantly horizontal. The test does not simu-

late the effect of regular seas giving the translational components of surging,

swaying and heaving, and the corresponding rotational components of rolling,

pitching and yawing which generally produce accelerations too small to be of

consequence to electronic equipment.

A resonance search shall be carried out throughout the test.

During the resonance search the EUT shall be externally observed, by unaided

visual and aural means, for obvious signs of any resonances of components or

sub-assemblies, which may affect the integrity of the EUT. Such observations

shall be recorded in the test report.

If any resonance, as measured by a sensor fixed to the outside of the EUT at the

location where obvious signs of resonance have been observed, has a magni-

tude ratio 5 measured relative to the surface where the EUT is fastened, the

EUT shall be subjected to a vibration endurance test at each resonant frequency

at the vibration level specified in the test with a duration of 2 h.

Page 11: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 11 of 147

When resonant frequencies with magnitude ratios 5 are harmonically related,

only the fundamental shall be tested. If no resonance with a magnitude ratio 5

occurs, the endurance test shall be carried out at one single observed frequen-

cy. If no resonance occurred, the endurance test shall be carried out at a fre-

quency of 30 Hz.

Performance check(s) shall be carried out at least once during each endurance

test period, and once before the end of each endurance test period.

The procedure shall be repeated with vibration in each of two mutually perpen-

dicular directions in the horizontal plane.

Test Severity

Frequency range 5 Hz to 100 Hz

Cross-over frequency 13.2 Hz

Displacement amplitude below the cross-over frequency 1 mm

Acceleration amplitude above the cross-overfrequency 7 m/s²

Sweep rate 0.5 octaves/min

Axis X, Y, Z

Voltage during Performance checks U = 100 V / 240 V; f = 50 Hz / 60 Hz(Normal power supply)

Page 12: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 12 of 147

1.6 Excessive power supply

These conditions exceed the extreme test conditions in which the EUT is re-

quired to operate, with or without performance degradation, as indicated in the

equipment standard. Excessive current is defined as greater than normal work-

ing current.

Excessive voltage is greater than specified in 5.2.2. Protection shall be provided

against such excesses at an appropriate level chosen by the manufacturer and,

when activated, may require the EUT to be reset, for example by fuse replace-

ment. The power supply shall be adjusted to cause activation of the protection

and after EUT reset, a performance check under normal test conditions shall be

carried out.

Power supply misconnections are also regarded as excessive conditions. Where

appropriate, the EUT shall be subjected to an input from a power supply of re-

versed polarity or improper phase sequence for a period of 5 min. After comple-

tion of the test, and reset of the protection of the EUT, if required, the power

supply shall be connected normally and a performance check shall be carried

out.

Test Severity

Temperature 20 °C

Duration 5 minutes

Voltage during Excessive power supply U=288V f= 50 Hz / 60 Hz

Voltage during performance check U = 100 V / 240 V; f = 50 Hz / 60 Hz(Normal power supply)

Page 13: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 13 of 147

1.7 Operating states and test set-up

Provided for testing is a complex assembly of devices in a KVM matrix switch sys-

tem. For these purposes, a digital KVM matrix switch (DVICenter DP32) with PC

connecting devices (targets: DVI-U-CPU-MC2-UC, U2-R-CPU) and console

devices ( DVI-U-CON-MC4, U2-R-CON) with related power supplies (Multipower-

12, MultiPower-6, SinPro SPU25A-105 and SinPro SPU63-105) was built.

As test equipment a PC (signal source), monitors (display video signal), key-

boards and mouse were used to control the complete system.

The logging function of A (DVICenter DP32) allows the observation of the KVM

system for malfunctions. The monitoring function allows also the logging of events

without functional effects like:

- Voltage drop at power supply of A - H and W (A - E directly and F, G, H, W

indirectly)

- Malfunctions and transmission errors at the CAT.x ethernet cables

- Data connection errors to the devices B, C, D and E

The logging is done by the PC. The Monitoring and the description is provided by

the applicant.

Page 14: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 14 of 147

Picture 1: Schematic test setup

F

B

D

C

E

JA

G

W

N

O

P

R

K

L

M

S

T

U

Q 230VAC

230VAC

230VAC

CAT

.x5m

CAT

.x5m

CAT

.x5m

CAT

.x5m

CAT

.x5m

CAT

.x5m

CAT

.x5m

CAT

.x5m

Power-Loop 1m

Power-Loop 1m

USB 5m

RS232 5m

DVI-D 5mDVI-D 5m

USB 5mLine In Audio 5m

VUSB1,8m

Twin-PS/25m

H

Ethernet 5m

Z AA

X YSubD9 5m

ACAB10 4 Power-

Cord 5mPower-

Cord 5m

AD

USB-Service an J

DVI-D 5m DVI-D 1,8m

AE

AF

Line Out Audio 5m

AG

A: DVICenter DP32

B: U2-R-CPU

C: U2-R-CON

D: DVI-U-CPU-MC2-UC

E: DVI-U-CON-MC4

F: MultiPower-12

G: MultiPower-6

H: PowerSet12 Typ3

SinPro SPU25A-105

J: Test-PC (Dell Optiplex 740)

K: USB2.0- Flashdrive

(Intenso, yellow)

L: USB2.0- Flashdrive

(PNY, black)

M: RS-232 Loopback-Dongle

N: Monitor 1 (Dell 2408WFPb)

O: Monitor 2

(Eizo Flexscan S2410W)

P: Speaker (Logitech LS11)

Q: Power supply for speaker

(Logitech G100050A31)

Page 15: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 15 of 147

R: Keyboard USB (ateg InduKey)

S: Mouse USB (ateg InduMouse)

T: Keyboard PS/2 (ateg InduKey)

U: Mouse PS/2 (ateg InduMouse)

V: USB-PS2 converter

(G&D USB-CPU)

W: PowerSet12 Typ2

SinPro SPU63-105

X: Power-Status-Box

Y: Power-Status-Box

Z: PowerSet12 Typ3

SinPro SPU25A-105

AA: PowerSet12 Typ3

SinPro SPU25A-105

AB: Load (resistor) ~ 600 mA

AC: Load (resistor) ~1.2 A

AD: Video analysis by

DL-Vision (M)-MC2-CPU

AE: Audio splitter

AF: Audio bridge (cable, 2 m)

AG: TS-LED-2

Note: EUTs were highlighted bold.

Page 16: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 16 of 147

DVICenter DP32

The MatrixSwitch (A) establishes the connections between the devices B, C, D

and E.

Criteria for correct function:

- uninterrupted operation of the devices B, C, D and E

- State LED "Main Power" and "Red. Power" glows green

- Log shows no error

U2-R-CPU

The USB- target serves in combination with C (U2-R-CON) over A (DVICenter

DP32) the signal transmission of USB and RS232.

Criteria for correct function:

- Uninterrupted data transmission of the test program on J over the RS232-

"Loopback"

- Uninterrupted video playback from the USB- flash drive at C (U2-R-CON)

U2-R-CON

The console unit serves in combination with C (U2-R-CON) over A (DVICenter

DP32) the signal transmission of USB and RS232.

Criteria for correct function:

- Uninterrupted data transmission of the test program on J over the RS232-

"loopback"

- Uninterrupted video playback from the USB- flash drive at C (U2-R-CON)

Page 17: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 17 of 147

DVI-U-CPU-MC2-UC

The DVI-KVM-target serves in combination with E (DVI-U-CON-MC4) over A

(DVICenter DP32) the signal transmission of DVI, keyboard, mouse, USB and

audio. Optionally the system provides an alternative signal path over an addi-

tional DVICenter.

Criteria for correct function:

- Uninterrupted DVI-signal transmission to the monitors at E

(DVI-U-CON-MC4)

- The power- LED glows green

- Keyboard and mouse at E (DVI-U-CON-MC4) usable

- No critical status notifications of D in the log of DVICenter DP32.

- Uninterrupted function of the USB- flashdrive L at E.

- Uninterrupted transmission of the audio signal at E (line- In and line- out

bridged)

Page 18: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 18 of 147

DVI-U-CON-MC4The DVI-KVM-target serves in combination with E (DVI-U-CON-MC4) over A

(DVICenter DP32) the signal transmission of DVI, keyboard, mouse, USB and

Audio. Optionally two separate DVI- connectors for up to 4 DVI- signal transmis-

sions are available (in association with several targets). The DVI- port 4 were

chosen because of the fact that DVI- port 4 shows correct function if the internal

connections (1 to 2, 2 to 3, 3 to 4) and the data processing components works

correct. The DVI Channels 2, 3 and 4 are identically constructed.

Criteria for correct function:

- Uninterrupted DVI- signal transmission to the Monitors at DVI- Port 1

and 4

- The LEDs "Main power" and "Red. power" glows green

- Keyboard and mouse are usable

- No critical status notifications of E in the log of DVICenter DP32.

- Uninterrupted function of the USB- flashdrive L.

- Uninterrupted transmission of the audio signal at D (line- in and line- out

bridged)

Page 19: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 19 of 147

MultiPower-12The device is the power supply for B (U2-R-CPU) and other devices.

In the temperature range up to 45 °C 12 nominal loads with up to 600 mA are

acceptable. In the temperature range up to 45 - 55 °C only 11 nominal Loads

with up to 600 mA are acceptable. The output 12 may be deactivated.

Criteria for correct function:

- Uninterrupted power supply of B

- Status LED "Main power" and "Red. power" glows green

- The status LEDs at X glows green

- The LEDs at the power ports glows green (12 up to 45 °C and 11 up to

55°C)

Due to the overload and overtemperature protection mechanism of the device

the upper ports are deactivated first. The device B is connected to port 11.

MultiPower-6The device is the power supply for C (U2-R-CON) and other devices.

In the temperature range up to 45 °C 6 nominal loads with up to 1200 mA are

acceptable. In the temperature range up to 45 - 55 °C only 5 nominal loads with

up to 1200 mA are acceptable. The output 6 may be deactivated.

Criteria for correct function:

- Uninterrupted power supply of C

- Status LED "Main power" and "Red. power" glows green

- The status LEDs at Y glows green

- The LEDs at the power ports glows green (6 up to 45 °C and 5 up to

55°C)

Due to the overload and overtemperature protection mechanism of the device

the upper ports are deactivated at first. The device C is connected to port 5.

Page 20: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 20 of 147

PowerSet 12 Typ3 SinPro SPU25A-105The device is the power supply for D (DVI-U-CPU-MC2-UC).

Criteria for correct function:

- Uninterrupted power supply of D

- State LED “Power” at D glows green

PowerSet 12 Typ2 SinPro SPU63-105The device is the power supply for E (DVI-U-CON-MC4).

Criteria for correct function:

- Uninterrupted power supply of E

- State LED “Red. power” at E glows green

Page 21: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 21 of 147

1.8 Monitoring of the EUT during the Test

The permanent correct function during the tests is monitored by several test pro-

grams. The programs creates log-files which allows the detection of malfunctions

or interruptions of normal operation.

Test programs are:

- Audio SweepGen & external monitoring equipment

- SerialMon

- RS232 (FSer-test)

- Flash Drive / Card Tester

- Windows Media Player

Page 22: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 22 of 147

Audio SweepGen & external Monitoring

The program generates a simple sine signal which is provided by the PC over

the line out. This signal is fed into DVI-U-CPU-MC2-UC and transmitted over

DVICenter DP32 to DVI-U-CON-MC4. At DVI-U-CON-MC4 the audio signal is

provided over a line- out connector. Over an external cable connection the sig-

nal is fed back to the DVI-U-CON-MC4 (over Line-in connector). After that the

signal is send back to the PC over the same path (DVI-U-CON-MC4 >> DVICen-

ter DP32 >> DVI-U-CPU-MC2-UC). At the line out connector of the DVI-U-CPU-

MC2-UC device a PC measures the amplitude of the audio signal.

Page 23: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 23 of 147

SerialMon

The AD DL-Vision(M)-AR-MC2-CPU inspects the parameters of the DVI- Signals

for the State "stable Picture". In case of a change of picture resolution, refresh

rate or signal interruption an appropriate message is generated and saved. Only

one message is allowed after startup. During the test no critical messages

should be recorded.

Critical failures are:

- failures of a power supply device

- transmission errors over the Ethernet cables

- interruptions of the communication between the devices A - E

Allowed messages are:

- Frame repeated, ignore - messages (part of normal communication)

- messages which shows the exceeding of temperature levels (During testswith high temperatures)

The devices F, G, H and W were monitored indirectly because a defect of a

power supply results in a shutdown of the connected device which results in a

failure of one of the key features.

Page 24: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 24 of 147

FSerTestThe PC sends data over U2-R-CPU and DVICenter DP32 to U2-R-CON. By an

external adapter (loopback) the data is sent back to the PC over the same path

(U2-R-CON >> DVICenter DP32 >> U2-R-CPU).

The program on the PC compares the sent and the received data. After the

completion of the test the program creates a statistical analysis. In the statistic

no nonconforming or lost packages should be included.

Page 25: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 25 of 147

Flash Drive / Card TesterThe programm cyclically reads from the USB- Flashdrive at the DVI-U-CON-

MC4. Data connections through DVI-U-CPU-MC2-UC and DVICenter DP32 are

used for this purpose. During the test no interruptions should be identified.

Page 26: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 26 of 147

Windows Media Player

Test for the USB- Flashdrive at U2-R-CON over DVICenter DP32 and U2-R-

CPU. Playback of a Video in a endless-loop. The Video is stored on the Flash-

drive. In case of an Failure the playback is stoped and a error message is

shown.

Page 27: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 27 of 147

2 Test performance and test results

2.1 Test performance

The tests are carried out as follows:

EUT Test Axis Date of test

144305 – Ato

144305 - W

Resonance search5 Hz to 100 Hz

X, Y, Z01.09.2014

-15.09.2014

Vibration Dwell X, Y, Z01.09.2014

-15.09.2014

Dry heat, storage ---17.09.2014

–18.09.2014

Dry heat, functional test ---18.09.2014

–19.09.2014

Cold, functional test ---22.09.2014

–23.09.2014

Damp heat, functional test ---23.09.2014

–24.09.2014

Excessive power supply --- 30.09.2014

Page 28: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 28 of 147

2.2 Test results

2.2.1 Resonance search

EUT Test Axis Comments Requirementsfulfilled

144305 - A

Resonancesearch

5 Hz to 100 HzZ

1)

Diagrams, see paragraph 5

144305 – E&

144305 – W2) 9)

144305 – F 3)

144305 – G 4)

144305 – Bto

144305 – D&

144305 – H

5) 6) 7) 8)

Note: 1) 144305 – A (DVICenter DP32) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 2) Ethernet port: magnitude ratio < 5 @ 100 Hz (see Diagram 3) Mounting plate fan: magnitude ratio < 5 @ 100 Hz (see Diagram 4) PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 5)

2) 144305 – E (DVI-U-CON-MC4) USB port PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 12) PCB center: magnitude ratio < 5 @ 100 Hz (see Diagram 13) AC filter : magnitude ratio < 5 @ 100 Hz (see Diagram 14) Housing center: magnitude ratio < 5 @ 100 Hz (see Diagram 15)

3) 144305 – F (MultiPower 12) Mounting plate fan: magnitude ratio < 5 @ 100 Hz (see Diagram 16) Heat sink power supply: magnitude ratio < 5 @ 100 Hz (see Diagram 17) Housing : magnitude ratio < 5 @ 100 Hz (see Diagram 19) PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 18)

4) 144305 – G (MultiPower 6) Mounting plate fan: magnitude ratio < 5 @ 95.982 Hz (see Diagram 20) PCB: magnitude ratio > 5 @ 95.982 Hz (see Diagram 21) Housing: magnitude ratio < 5 @ 95.982 Hz (see Diagram 22)

5) 144305 – B (U2-R-CPU) PCB: no resonances (see Diagram 6) Housing: no resonances (see Diagram 7)

6) 144305 – D (DVI-U-CPU-MC2-UC) PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 10)

Page 29: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 29 of 147

Housing : magnitude ratio < 5 @ 100 Hz (see Diagram 11)

7) 144305 – C (U2-R-CON) PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 8) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 9)

8) 144305 – W (PowerSet12 Typ 2) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 73)

9) 144305 – H (PowerSet12 Typ 3) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 70)

Page 30: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 30 of 147

EUT Test Axis Comments Requirementsfulfilled

144305 – Bto

144305 – D&

144305 – HResonance

search5 Hz to 100 Hz

Y

5) 6) 7) 9)

Diagrams, see paragraph 5144305 – G 4)

144305 – F 3)

144305 – E&

144305 – W2) 8)

144305 – A 1)

Note: 1) 144305 – A (DVICenter DP32) Capacitor: no resonances (see Diagram 46) Ethernet port: no resonances (see Diagram 48) Mounting plate fan: no resonances (see Diagram 47) Housing: no resonances (see Diagram 49)

2) 144305 – E (DVI-U-CON-MC4) Ethernet port: no resonances (see Diagram 56) Heat sink voltage regulator: no resonances (see Diagram 58) AC filter: no resonances (see Diagram 57) Housing: no resonances (see Diagram 59)

3) 144305 – F (MultiPower 12) Capacitor power module: no resonances (see Diagram 60) Capacitor main PCB: no resonances (see Diagram 62) Housing: no resonances (see Diagram 61)

4) 144305 – G (MultiPower 6) AC filter: magnitude ratio < 5 @ 100 Hz (see Diagram 64) Mounting plate fan: magnitude ratio < 5 @ 100 Hz (see Diagram 65) Power connector PCB: no resonances (see Diagram 63) Housing: no resonances (see Diagram 66) Heat sink: magnitude ratio < 5 @ 69.53 Hz (see Diagram 67)

5) 144305 – B (U2-R-CPU) USB Port / PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 50) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 51)

6) 144305 – D (DVI-U-CPU-MC2-UC) Ethernet Port / PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 54) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 55)

Page 31: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 31 of 147

7) 144305 – C (U2-R-CON) USB Port / PCB: magnitude ratio < 5 @ 74.59 Hz (see Diagram 53) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 52)

8) 144305 – W (PowerSet12 Typ 2) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 72)

9) 144305 – H (PowerSet12 Typ 3) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 69)

Page 32: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 32 of 147

EUT Test Axis Comments Requirementsfulfilled

144305 – Bto

144305 – D&

144305 – HResonance

search5 Hz to 100 Hz

X

5) 6) 7) 9)

Diagrams, see paragraph 5144305 – A 4)

144305 – E&

144305 – W3) 8)

144305 – F 2)

144305 – G 1)

Note: 1) 144305 – A (DVICenter DP32) LED socket rear: no resonances (see Diagram 23) Battery socket: no resonances (see Diagram 24) AC Filter: no resonances (see Diagram 25) Ethernet Port: magnitude ratio < 5 @ 100 Hz (see Diagram 27) Housing: no resonances (see Diagram 26)

2) 144305 – E (DVI-U-CON-MC4) Capacitor power module: magnitude ratio < 5 @ 100 Hz (see Diagram 35) Heat sink voltage regulator: magnitude ratio < 5 @ 100 Hz (see Diagram 37) USB Port main PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 34) Housing: no resonances (see Diagram 36)

3) 144305 – F (MultiPower 12) Coil power module: magnitude ratio < 5 @ 100 Hz (see Diagram 38) Heat sink power supply: magnitude ratio < 5 @ 100 Hz (see Diagram 39) Housing: magnitude ratio < 5 @ 68.32 Hz (see Diagram 40) Capacitor PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 41)

4) 144305 – G (MultiPower 6) Heat sink power module: magnitude ratio < 5 @ 100 Hz (see Diagram 44) Capacitor main PCB: magnitude ratio < 5 @ 91.0488 Hz (see Diagram 45) PCB power connector: magnitude ratio < 5 @ 67.1241 Hz (see Diagram 43) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 42)

5) 144305 – B (U2-R-CPU) USB Port PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 29) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 28)

6) 144305 – D (DVI-U-CPU-MC2-UC) PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 33) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 32)

Page 33: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 33 of 147

7) 144305 – C (U2-R-CON) Ethernet Port PCB: magnitude ratio < 5 @ 100 Hz (see Diagram 31) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 30)

8) 144305 – W (PowerSet12 Typ 2) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 71)

9) 144305 – H (PowerSet12 Typ 3) Housing: magnitude ratio < 5 @ 100 Hz (see Diagram 68)

Page 34: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 34 of 147

2.2.2 Vibration, sinusoidal

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

- Performance check during the durability test

EUT Test Axis Performancecheck

Visualdamages

Requirementsfulfilled

144305 – A

Vibration Dwell30 Hz for 2 h

X OK None YES

Vibration Dwell30 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

144305 – B

Vibration Dwell100 Hz for 2 h

X OK None YES

Vibration Dwell100 Hz for 2 h

Y OK None YES

Vibration Dwell30 Hz for 2 h

Z OK None YES

Note: During the performance check several status messages were reported by the DL- VisionMC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 35: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 35 of 147

EUT Test Axis Performancecheck

Visualdamages

Requirementsfulfilled

144305 – C

Vibration Dwell100 Hz for 2 h

X OK None YES

Vibration Dwell100 Hz for 2 h

YOK None YES

Vibration Dwell74.5947 Hz for 2 h

OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

144305 – D

Vibration Dwell100 Hz for 2 h

X OK None YES

Vibration Dwell100 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

144305 – E

Vibration Dwell100 Hz for 2 h

XOK None YES

Vibration Dwell30 Hz for 2 h

OK None YES

Vibration Dwell30 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

Note: During the performance check several status messages were reported by the DL- VisionMC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 36: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 36 of 147

EUT Test Axis Performancecheck

Visualdamages

Requirementsfulfilled

144305 – F

Vibration Dwell100 Hz for 2 h

XOK None YES

Vibration Dwell68.3151 Hz for 2 h

OK None YES

Vibration Dwell30 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

144305 – G

Vibration Dwell91.0481 Hz for 2 h

XOK None YES

Vibration Dwell67.1241 Hz for 2 h

OK None YES

Vibration Dwell30 Hz for 2 h

Y

OK None YES

Vibration Dwell100 Hz for 2 h

OK None YES

Vibration Dwell69.5273 Hz for 2 h

OK None YES

Vibration Dwell95.9818 Hz for 2 h

Z OK None YES

144305 – H

Vibration Dwell100 Hz for 2 h

X OK None YES

Vibration Dwell100 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

144305 –W

Vibration Dwell100 Hz for 2 h

X OK None YES

Vibration Dwell100 Hz for 2 h

Y OK None YES

Vibration Dwell100 Hz for 2 h

Z OK None YES

Note: During the performance check several status messages were reported by the DL- VisionMC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 37: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 37 of 147

2.2.3 Dry heat, storage test

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

EUT Temp. Testduration

Visualdamages

Performancecheck

Requirementsfulfilled

144305 – Ato

144305 – HAnd

144305 - W

+ 70 °C 16 h None OK YES

Note: During the performance check several status messages were reported by the DL- Vision-MC2-CPU. Malfunctions of the complete system or parts were not detected.

2.2.4 Dry heat, Functional test

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

- Performance test and check during the test

EUT Temp. Testduration

Visualdamages

Performancetest & check

Requirementsfulfilled

144305 – Ato

144305 – HAnd

144305 - W

+ 55 °C 16 h None OK YES

Note: During the performance test and check several status messages were reported by the DL-Vision-MC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 38: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 38 of 147

2.2.5 Cold, Low temperature Functional test

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

- Performance test and check during the test

EUT Temp. Testduration

Visualdamages

Performancetest & check

Requirementsfulfilled

144305 – Ato

144305 – HAnd

144305 - W

- 15 °C 16 h None OK YES

Note: During the performance test and check several status messages were reported by the DL-Vision-MC2-CPU. Malfunctions of the complete system or parts were not detected.

2.2.6 Damp heat, Functional test

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

- Performance check during the test

EUT Temp./Humidity

Testduration

Visualdamages

Performancecheck

Requirementsfulfilled

144305 – Ato

144305 – HAnd

144305 - W

+ 40 °C /

93 %16 h None OK Yes

Note: During the performance check several status messages were reported by the DL- Vision-MC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 39: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 39 of 147

2.2.7 Excessive power supply

Requirements: - Before and after the durability test a performance check will be carried out under normal test conditions

- Optical test for mechanical stability

EUT Temp./Humidity

Testduration

Visualdamages

Performancecheck

Requirementsfulfilled

144305 – Ato

144305 – HAnd

144305 - W

+ 40 °C /

93 %

5

minutesNone OK Yes

Note: During the performance check several status messages were reported by the DL- Vision-MC2-CPU. Malfunctions of the complete system or parts were not detected.

Page 40: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 40 of 147

3 List of measurement equipment

Measurement equipment PM Nr.

Shaker LDS V875-640 LPT 600 490022

Accelerometer 1.0496 mV/(m/s)² 481395

Accelerometer 1.054 mV/(m/s)² 480603

Accelerometer 5.048 mV/(m/s)² 481661

Accelerometer 1.026 mV/(m/s)² 481837

Accelerometer 0.9460 mV/(m/s)² 481833

Accelerometer 0.8658 mV/(m/s)² 481480

Accelerometer 1.1661 mV/(m/s)² 481483

Accelerometer 0.9807 mV/(m/s)² 481506

Temperature Cabinet VCS 7150-5 481264

Monitoring Equipment Customer Equipment

AC Power supply type HP6813B 480788

Monitoring equipment MW 10

Note: The QM-Manual of PHOENIX TESTLAB regulates the calibration of the measuringequipment. All listed measuring equipment is traceable calibrated according to nationalor international standards. Measurement uncertainty is calculated according to GUM.

Page 41: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 41 of 147

4 Pictures

Picture 2: Z- Axis, EUT 144305 – A, Test set-up resonance search

Page 42: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 42 of 147

Picture 3: Z- Axis EUT 144305 – A, position of accelerometers

Accelerometers for reso-nance measurement

- Center PCB- Mounting plate fan- Ethernet Port front

Page 43: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 43 of 147

Picture 4: Z- Axis EUT 144305 – A, position of accelerometer at housing

Page 44: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 44 of 147

Picture 5: Z- Axis, EUT 144305 – B; C & D, Test set-up resonance search

Page 45: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 45 of 147

Picture 6: Z- Axis EUT 144305 – B, position of accelerometers

Accelerometers forResonance Measurement:

- PCB Controller

Page 46: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 46 of 147

Picture 7: Z- Axis EUT 144305 – B, position of accelerometer at housing

Page 47: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 47 of 147

Picture 8: Z- Axis EUT 144305 – C, position of accelerometers

Accelerometers forResonance Measurement:

- PCB Controller

Page 48: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 48 of 147

Picture 9: Z- Axis EUT 144305 – C, position of accelerometer at housing

Page 49: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 49 of 147

Picture 10: Z- Axis EUT 144305 – D, position of accelerometers

Accelerometers forResonance Measurement:

- PCB

Page 50: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 50 of 147

Picture 11: Z- Axis EUT 144305 – D, position of accelerometer at housing

Page 51: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 51 of 147

Picture 12: Z- Axis, EUT 144305 – E, Test set-up resonance search

Page 52: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 52 of 147

Picture 13: Z- Axis EUT 144305 – E, position of accelerometers

Accelerometers forResonance Measurement:

- 2 Port USB on PCB- PCB Center- AC filter

Page 53: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 53 of 147

Picture 14: Z- Axis EUT 144305– E, position of accelerometer at housing

Page 54: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 54 of 147

Picture 15: Z- Axis, EUT 144305 –F, Test set-up resonance search

Page 55: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 55 of 147

Picture 16: Z- Axis EUT 144305 – F, position of accelerometers

Accelerometers forResonance Measurement:

- PCB Center- Mounting plate fan- Heat sink power supply

Page 56: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 56 of 147

Picture 17: Z- Axis EUT 144305 – F, position of accelerometer at housing

Page 57: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 57 of 147

Picture 18: Z- Axis, EUT 144305 – G, Test set-up resonance search

Page 58: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 58 of 147

Picture 19: Z- Axis EUT 144305 – G, position of accelerometers

Accelerometers forResonance Measurement:

- Mounting plate fan- PCB Center- AC filter

Page 59: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 59 of 147

Picture 20: Z- Axis EUT 144305 – G, position of accelerometer at housing

Page 60: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 60 of 147

Picture 21: X- Axis, EUT 144305 – A, Test set-up resonance search

Page 61: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 61 of 147

Picture 22: X- Axis EUT 144305 – A, position of accelerometers

Accelerometers forResonance Measurement:

- AC Filter- Battery holder- LED holder

Page 62: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 62 of 147

Picture 23: X- Axis EUT 144305 – A, position of accelerometer at housing

Page 63: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 63 of 147

Picture 24: X- Axis, EUT 144305 – B; C & D, Test set-up resonance search

Page 64: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 64 of 147

Picture 25: X- Axis EUT 144305 – B, position of accelerometers

Accelerometers forResonance Measurement:

- Ethernet Port

Page 65: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 65 of 147

Picture 26: X- Axis EUT 144305 – C, position of accelerometers, USB- Port

Accelerometers forResonance Measurement:

- USB- Port

Page 66: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 66 of 147

Picture 27: X- Axis EUT 144305 – C, position of accelerometer at housing

Page 67: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 67 of 147

Picture 28: X- Axis EUT 144305 – D, position of accelerometers

Accelerometers forResonance Measurement:

- PCB

Page 68: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 68 of 147

Picture 29: X- Axis, EUT 144305 – E, Test set-up resonance search

Page 69: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 69 of 147

Picture 30: X- Axis EUT 144305 – E, position of accelerometers

Accelerometers forResonance Measurement:

- USB- Port- Capacitor power module- Heat sink voltage regulator

Page 70: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 70 of 147

Picture 31: X- Axis EUT 144305 – E, position of accelerometer at housing

Page 71: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 71 of 147

Picture 32: X- Axis, EUT 144305 – F, Test set-up resonance search

Page 72: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 72 of 147

Picture 33: X- Axis EUT 144305 – F, position of accelerometers

Accelerometers forResonance Measurement:

- Coil power module- Heat sink power module- Capacitor main PCB

Page 73: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 73 of 147

Picture 34: X- Axis EUT 144305 – F, position of accelerometer at housing

Page 74: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 74 of 147

Picture 35: X- Axis, EUT 144305 – G, Test set-up resonance search

Page 75: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 75 of 147

Picture 36: X- Axis EUT 144305 – G, position of accelerometers

Accelerometers forResonance Measurement:

- Heat sink power module- Capacitor main PCB- Connector power module

Page 76: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 76 of 147

Picture 37: X- Axis EUT 144305 – G, position of accelerometer at housing

Page 77: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 77 of 147

Picture 38: Y- Axis, EUT 144305 – A, Test set-up resonance search

Page 78: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 78 of 147

Picture 39: Y- Axis EUT 144305 – A, position of accelerometers

Accelerometers forResonance Measurement:

- USB port- Ethernet Port- Mounting plate fan- Capacitor power module

Page 79: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 79 of 147

Picture 40: Y- Axis EUT 144305 – A, position of accelerometer at housing

Page 80: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 80 of 147

Picture 41: Y- Axis, EUT 144305 – B; C & D, Test set-up resonance search

Page 81: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 81 of 147

Picture 42: Y- Axis EUT 144305 – B, position of accelerometers

Accelerometers forResonance Measurement:

- USB- Port

Page 82: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 82 of 147

Picture 43: Y- Axis EUT 144305 – B, position of accelerometer at housing

Page 83: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 83 of 147

Picture 44: Y- Axis EUT 144305 – C, position of accelerometers

Accelerometers forResonance Measurement:

- USB Port

Page 84: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 84 of 147

Picture 45: Y- Axis EUT 144305 – D, position of accelerometers

Accelerometers forResonance Measurement:

- Ethernet Port

Page 85: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 85 of 147

Picture 46: Y- Axis EUT 144305 – D, position of accelerometer at housing

Page 86: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 86 of 147

Picture 47: Y- Axis, EUT 144305 – E, Test set-up resonance search

Page 87: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 87 of 147

Picture 48: Y- Axis EUT 144305 – E, position of accelerometers

Accelerometers forResonance Measurement:

- AC Filter- Coil power module- Ethernet port main PCB

Page 88: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 88 of 147

Picture 49: Y- Axis EUT 144305 – E, position of accelerometer at housing

Page 89: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 89 of 147

Picture 50: Y- Axis, EUT 144305 – F, Test set-up resonance search

Page 90: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 90 of 147

Picture 51: Y- Axis EUT 144305 – F, position of accelerometers

Accelerometers forResonance Measurement:

- Capacitor power module- Capacitor main PCB

Page 91: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 91 of 147

Picture 52: Y- Axis EUT 144305 – F, position of accelerometer at housing

Page 92: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 92 of 147

Picture 53: Y- Axis, EUT 144305 – G, Test set-up resonance search

Page 93: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 93 of 147

Picture 54: Y- Axis EUT 144305 – G, position of accelerometers

Accelerometers forResonance Measurement:

- AC Filter- Heat sink power module- Connector Power port

Page 94: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 94 of 147

Picture 55: Y- Axis EUT 144305 – G, position of accelerometer at housing

Page 95: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 95 of 147

Picture 56: EUTs in climatic cabinet

Page 96: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 96 of 147

Picture 57: Monitoring during climatic tests

Page 97: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 97 of 147

Picture 57: By the monitoring marked massages

Page 98: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 98 of 147

DiagramsDiagram 1: Vibration, Resonance search profile (exemplary)DUT: 144305 Gunthermann & DrunkSerial Number: Z-Achse Resosuche DVICenter DP32Project File Name: Resosuche.prjProfile Name: Low Level Test Type: Swept Sine Run Folder: .\RunDefault Sep 01, 2014 16-21-17

profile(f)

high-abort(f)

low-abort(f)

high-alarm(f)

low-alarm(f)

control(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Level: 100 % Full Level Time: 00:17:18 Sweep Type: LogarithmicFrequency: 5.001248 Hz Time Remaining: 00:00:00 Sweep Rate: 0.5 Oct/Min

Data saved at 04:49:31 PM, Monday, September 01, 2014 Report created at 04:49:32 PM, Monday, September 1, 2014

Page 99: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 99 of 147

Diagram 2: Resonance search Z- Axis, EUT 144305 – A Housing

profile(f)

RM 4 Housing center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center(f): 100.0026 Hz, 24.0429 m/s²

Diagram 3: Resonance search Z- Axis, EUT 144305 – A Ethernetport

profile(f)

RM 3 Ethernetport(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 Ethernetport(f): 99.8637 Hz, 17.6187 m/s²

Page 100: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 100 of 147

Diagram 4: Resonance search Z- Axis, EUT 144305 – A, Mounting plate fan

profile(f)

RM 2 Fan inside(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Fan inside(f): 100.0026 Hz, 27.6713 m/s²

Diagram 5: Resonance search Z- Axis, EUT 144305 – A, PCB

profile(f)

RM 1 PCB center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB center(f): 100.0026 Hz, 25.8914 m/s²

Page 101: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 101 of 147

Diagram 6: Resonance search Z- Axis, EUT 144305 – B, PCB

profile(f)

RM 1 PCB controler right U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB controler right U2-R-CPU(f): 100.0026 Hz, 6.9077 m/s²

Diagram 7: Resonance search Z- Axis, EUT 144305 – B, Housing

profile(f)

RM 4 Housing center U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center U2-R-CPU(f): 100.0026 Hz, 7.2859 m/s²

Page 102: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 102 of 147

Diagram 8: Resonance search Z- Axis, EUT 144305 – C, PCB

profile(f)

RM 3 PCB controler left U2-R-CON(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 PCB controler left U2-R-CON(f): 100.0026 Hz, 7.9365 m/s²

Diagram 9: Resonance search Z- Axis, EUT 144305 – C, Housing

profile(f)

RM 4 Housing center U2-R-CON(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

profile(f): 100.0026 Hz, 7.0000 m/s²

Page 103: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 103 of 147

Diagram 10: Resonance search Z- Axis, EUT 144305 – D, PCB

profile(f)

RM 2 PCB DVI-U-CPU-MC2-UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 PCB DVI-U-CPU-MC2-UC(f): 100.0026 Hz, 7.4849 m/s²

Diagram 11: Resonance search Z- Axis, EUT 144305 – D, Housing

profile(f)

RM 4 Housing center DVI-U-CPU-MC2-UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center DVI-U-CPU-MC2-UC(f): 100.0026 Hz, 7.6020 m/s²

Page 104: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 104 of 147

Diagram 12: Resonance search Z- Axis, EUT 144305 – E, USB- Port PCB

profile(f)

RM 3 USB PCB rear(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 USB PCB rear(f): 100.0026 Hz, 8.3063 m/s²

Diagram 13: Resonance search Z- Axis, EUT 144305 – E, PCB

profile(f)

RM 1 PCB center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB center(f): 100.0026 Hz, 16.8534 m/s²

Page 105: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 105 of 147

Diagram 14: Resonance search Z- Axis, EUT 144305 – E, AC filter

profile(f)

RM 2 AC Filter(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 AC Filter(f): 100.0026 Hz, 9.6235 m/s²

Diagram 15: Resonance search Z- Axis, EUT 144305 – E, Housing

profile(f)

RM 4 Housing center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center(f): 100.0026 Hz, 16.9415 m/s²

Page 106: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 106 of 147

Diagram 16: Resonance search Z- Axis, EUT 144305 – F, mounting plate fan

profile(f)

RM 2 Fan(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Fan(f): 100.0026 Hz, 14.5738 m/s²

Diagram 17: Resonance search Z- Axis, EUT 144305 – F, heat sink power supply

profile(f)

RM 3 heat sink power supply(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 heat sink power supply(f): 100.0026 Hz, 18.0545 m/s²

Page 107: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 107 of 147

Diagram 18: Resonance search Z- Axis, EUT 144305 – F, PCB center

profile(f)

RM 1 PCB center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB center(f): 100.0026 Hz, 20.1209 m/s²

Diagram 19: Resonance search Z- Axis, EUT 144305 – F, Housing center

profile(f)

RM 4 Housing center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center(f): 100.0026 Hz, 12.8929 m/s²

Page 108: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 108 of 147

Diagram 20: Resonance search Z- Axis, EUT 144305 – G, Mounting plate fan

profile(f)

RM 2 Fan rear side(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Fan rear side(f): 95.9818 Hz, 18.7211 m/s²

Diagram 21: Resonance search Z- Axis, EUT 144305 – G, PCB center

profile(f)

RM 1 PCB center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB center(f): 95.9818 Hz, 36.5325 m/s²

Page 109: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 109 of 147

Diagram 22: Resonance search Z- Axis, EUT 144305 – G, Housing center

profile(f)

RM 4 Housing center(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center(f): 95.9818 Hz, 25.2358 m/s²

Page 110: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 110 of 147

Diagram 23: Resonance search X- Axis, EUT 144305 – A, LED socket

profile(f)

RM 1 LED socket(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 24: Resonance search X- Axis, EUT 144305 – A, Battery socket

profile(f)

RM 3 Batterie(f)

100.005.00 10.00

12.5893

0.7943

1.0000

10.0000

Frequency (Hz)

m/s²

Page 111: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 111 of 147

Diagram 25: Resonance search X- Axis, EUT 144305 – A, AC- Filter

profile(f)

RM 2 Netfilter(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 26: Resonance search X- Axis, EUT 144305 – A, Housing DVI

profile(f)

RM 4 housing DVI Center DP 32(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Page 112: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 112 of 147

Diagram 27: Resonance search X- Axis, EUT 144305 – A, Ethernet port

profile(f)

RM 5 heat sink (black)(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 heat sink (black)(f): 100.0026 Hz, 7.5902 m/s²

Ethernet port

Page 113: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 113 of 147

Diagram 28: Resonance search X- Axis, EUT 144305 – B, Housing center

profile(f)

RM 4 Housing center U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center U2-R-CPU(f): 100.0026 Hz, 7.7353 m/s²

Diagram 29: Resonance search X- Axis, EUT 144305 – B, PCB USB

profile(f)

RM 1 PCB USB U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 PCB USB U2-R-CPU(f): 100.0026 Hz, 7.6189 m/s²

Page 114: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 114 of 147

Diagram 30: Resonance search X- Axis, EUT 144305 – C, Housing center

profile(f)

RM 4 Housing center U2-R-CON(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing center U2-R-CON(f): 100.0026 Hz, 8.5552 m/s²

Diagram 31: Resonance search X- Axis, EUT 144305 – C, PCB Ethernet port

profile(f)

RM 3 PCB Ethernet left U2-R-CON(f)

100.005.00 10.00

12.5893

0.7499

1.0000

10.0000

Frequency (Hz)

m/s²

Page 115: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 115 of 147

Diagram 32: Resonance search X- Axis, EUT 144305 – D, Housing center

profile(f)

RM 5 Housing DVI U CPU MC2 UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 Housing DVI U CPU MC2 UC(f): 100.0026 Hz, 8.1735 m/s²

Diagram 33: Resonance search X- Axis, EUT 144305 – D, PCB

profile(f)

RM 2 PCB DVI-U-CPU-MC2-UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 PCB DVI-U-CPU-MC2-UC(f): 100.0026 Hz, 8.0683 m/s²

Page 116: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 116 of 147

Diagram 34: Resonance search X- Axis, EUT 144305 – E, USB port

profile(f)

RM 1 USB port front(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 USB port front(f): 100.0026 Hz, 7.4228 m/s²

Diagram 35: Resonance search X- Axis, EUT 144305 – E, Capacitor

profile(f)

RM 2 Capacitor(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Capacitor(f): 100.0026 Hz, 7.9799 m/s²

Page 117: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 117 of 147

Diagram 36: Resonance search X- Axis, EUT 144305 – E, Housing center

profile(f)

RM 4 housing DVI-U-CON-MC4(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 37: Resonance search X- Axis, EUT 144305 – E, heat sink

profile(f)

RM 5 heat sink (black)(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 heat sink (black)(f): 100.0026 Hz, 7.5902 m/s²

Page 118: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 118 of 147

Diagram 38: Resonance search X- Axis, EUT 144305 – F, Coil

profile(f)

RM 5 coil(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 coil(f): 100.0026 Hz, 10.5346 m/s²

Diagram 39: Resonance search X- Axis, EUT 144305 – F, heat sink power module

profile(f)

RM 1 heat sink power module(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 heat sink power module(f): 100.0026 Hz, 14.1036 m/s²

Page 119: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 119 of 147

Diagram 40: Resonance search X- Axis, EUT 144305 – F, Housing center

profile(f)

RM 4 housing Multipower 12(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 41: Resonance search X- Axis, EUT 144305 – F, Capacitor main PCB

profile(f)

RM 2 Capacitor main PCB(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Capacitor main PCB(f): 68.3151 Hz, 8.5008 m/s²

Page 120: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 120 of 147

Diagram 42: Resonance search X- Axis, EUT 144305 – G, housing center

profile(f)

RM 4 housing Multipower 6(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 housing Multipower 6(f): 100.0026 Hz, 7.8351 m/s²

Diagram 43: Resonance search X- Axis, EUT 144305 – G, PCB Power connector

profile(f)

RM 5 PCB power connector 4(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 PCB power connector 4(f): 67.1241 Hz, 8.5553 m/s²

Page 121: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 121 of 147

Diagram 44: Resonance search X- Axis, EUT 144305 – G, heat sink power module

profile(f)

RM 1 heat sink power module(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 heat sink power module(f): 100.0026 Hz, 14.1933 m/s²

Diagram 45: Resonance search X- Axis, EUT 144305 – G, Capacitor main PCB

profile(f)

RM 2 Capacitor main PCB(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 Capacitor main PCB(f): 91.0488 Hz, 7.5002 m/s²

Page 122: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 122 of 147

Diagram 46: Resonance search Y- Axis, EUT 144305 – A, Capacitor

profile(f)

RM 1 Capacitor(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 47: Resonance search Y- Axis, EUT 144305 – A, fan

profile(f)

RM 3 fan(f)

100.005.00 10.00

10.0000

0.7943

1.0000

Frequency (Hz)

m/s²

Page 123: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 123 of 147

Diagram 48: Resonance search Y- Axis, EUT 144305 – A, Ethernet port

profile(f)

RM 2 ETH port front(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 49: Resonance search Y- Axis, EUT 144305 – A, Housing center

profile(f)

RM 4 housing DVI Center DP 32(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Page 124: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 124 of 147

Diagram 50: Resonance search Y- Axis, EUT 144305 – B, USB port

profile(f)

RM 1 USB port U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 USB port U2-R-CPU(f): 100.0026 Hz, 7.8761 m/s²

Diagram 51: Resonance search Y- Axis, EUT 144305 – B, housing center

profile(f)

RM 4 Housing U2-R-CPU(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing U2-R-CPU(f): 100.0026 Hz, 8.0860 m/s²

Page 125: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 125 of 147

Diagram 52: Resonance search Y- Axis, EUT 144305 – C, Housing center

profile(f)

RM 4 Housing U2-R-CON(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 Housing U2-R-CON(f): 100.0026 Hz, 7.9998 m/s²

Diagram 53: Resonance search Y- Axis, EUT 144305 – C, USB port

profile(f)

RM 3 USB port U2-R-CON(f)

100.005.00 10.00

12.5893

0.7762

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 USB port U2-R-CON(f): 74.5947 Hz, 7.7910 m/s²

Page 126: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 126 of 147

Diagram 54: Resonance search Y- Axis, EUT 144305 – D, Ethernet port

profile(f)

RM 2 ETH port DVI-U-CPU-MC2-UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 ETH port DVI-U-CPU-MC2-UC(f): 100.0026 Hz, 7.8697 m/s²

Diagram 55: Resonance search Y- Axis, EUT 144305 – D, Housing center

profile(f)

RM 5 Housing DVI U CPU MC2 UC(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 Housing DVI U CPU MC2 UC(f): 100.0026 Hz, 8.0530 m/s²

Page 127: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 127 of 147

Diagram 56: Resonance search Y- Axis, EUT 144305 – E, Ethernet port

profile(f)

RM 1 ETH port(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 57: Resonance search Y- Axis, EUT 144305 – E, AC- filter

profile(f)

RM 3 Netfilter(f)

100.005.00 10.00

10.0000

0.7943

1.0000

Frequency (Hz)

m/s²

Page 128: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 128 of 147

Diagram 58: Resonance search Y- Axis, EUT 144305 – E, heat sink power module

profile(f)

RM 2 heat sink power unit(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 59: Resonance search Y- Axis, EUT 144305 – E, housing center

profile(f)

RM 4 housing DVI - U - CON - MC4(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Page 129: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 129 of 147

Diagram 60: Resonance search Y- Axis, EUT 144305 – F, capacitor main PCB

profile(f)

RM 1 capacitor PCB(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Diagram 61: Resonance search Y- Axis, EUT 144305 – F, Housing center

profile(f)

RM 4 housing(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Page 130: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 130 of 147

Diagram 62: Resonance search Y- Axis, EUT 144305 – F, capacitor power module

profile(f)

RM 2 capacitor power supply(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

Page 131: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 131 of 147

Diagram 63: Resonance search Y- Axis, EUT 144305 – G, Power out

profile(f)

RM 4 power out 5(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 4 power out 5(f): 100.0026 Hz, 7.5654 m/s²

Diagram 64: Resonance search Y- Axis, EUT 144305 – G, AC- filter

profile(f)

RM 3 netfilter(f)

100.005.00 10.00

12.5893

0.7943

1.0000

10.0000

Frequency (Hz)

m/s²

RM 3 netfilter(f): 100.0026 Hz, 7.5431 m/s²

Page 132: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 132 of 147

Diagram 65: Resonance search Y- Axis, EUT 144305 – G, fan

profile(f)

RM 2 fan(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 2 fan(f): 100.0026 Hz, 8.2752 m/s²

Diagram 66: Resonance search Y- Axis, EUT 144305 – G, housing center

profile(f)

RM 5 housing Multipower 6(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 5 housing Multipower 6(f): 100.0026 Hz, 7.4007 m/s²

Page 133: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 133 of 147

Diagram 67: Resonance search Y- Axis, EUT 144305 – G, heat sink

profile(f)

RM 1 heat sink left(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM 1 heat sink left(f): 69.5273 Hz, 7.4874 m/s²

Page 134: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 134 of 147

Diagram 68: Resonance search X- Axis, EUT 144305 – H, Housing

profile(f)

RM1 Housing(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing(f): 99.3809 Hz, 9.6064 m/s²

Diagram 69: Resonance search Y- Axis, EUT 144305 – H, Housing

profile(f)

RM1 Housing(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing(f): 99.2737 Hz, 7.4102 m/s²

Page 135: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 135 of 147

Diagram 70: Resonance search Z- Axis, EUT 144305 – H, Housing

profile(f)

RM1 Housing(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing(f): 99.3809 Hz, 7.5065 m/s²

Note: During the Resonance search and the Dwell Test the power supplies H & W were fastened by cable retainer at the swing table. This was done because the fitting condition during normal use could not be warranted.

The resonances at 45 Hz are a result of the control system of the shaker.

Page 136: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 136 of 147

Diagram 71: Resonance search X- Axis, EUT 144305 – W, Housing

profile(f)

RM1 Housing.(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing.(f): 99.4104 Hz, 9.9760 m/s²

Diagram 72: Resonance search Y- Axis, EUT 144305 – W, Housing

profile(f)

RM1 Housing.(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing.(f): 99.3082 Hz, 8.6237 m/s²

Page 137: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 137 of 147

Diagram 73: Resonance search Z- Axis, EUT 144305 – W, Housing

profile(f)

RM1 Housing(f)

100.005.00 10.00

50.0000

0.5000

1.0000

10.0000

Frequency (Hz)

m/s²

RM1 Housing(f): 99.3809 Hz, 8.0205 m/s²

Note: During the Resonance search and the Dwell Test the power supplies H & W were fastened by cable retainer at the swing table. This was done because the fitting condition during normal use could not be warranted.

The resonances at 45 Hz are a result of the control system of the shaker.

Page 138: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 138 of 147

Diagram 74: Temperature profile, Dry heat storage

Page 139: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 139 of 147

Diagram 75: Temperature profile, Dry heat function

Page 140: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 140 of 147

Diagram 76: Temperature profile, Low temperature function

Page 141: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 141 of 147

Diagram 77: Climatic profile, Humidity, function

Page 142: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 142 of 147

Diagram 78: Monitoring Audio Signal, Humidity, function (exemplary)

Page 143: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 143 of 147

5 List of pictures

Picture 1: Schematic test setup ..................................................................................... 14

Picture 2: Z- Axis, EUT 144305 – A, Test set-up resonance search ............................. 41

Picture 3: Z- Axis EUT 144305 – A, position of accelerometers .................................... 42

Picture 4: Z- Axis EUT 144305 – A, position of accelerometer at housing .................... 43

Picture 5: Z- Axis, EUT 144305 – B; C & D, Test set-up resonance search.................. 44

Picture 6: Z- Axis EUT 144305 – B, position of accelerometers .................................... 45

Picture 7: Z- Axis EUT 144305 – B, position of accelerometer at housing .................... 46

Picture 8: Z- Axis EUT 144305 – C, position of accelerometers ................................... 47

Picture 9: Z- Axis EUT 144305 – C, position of accelerometer at housing.................... 48

Picture 10: Z- Axis EUT 144305 – D, position of accelerometers ................................. 49

Picture 11: Z- Axis EUT 144305 – D, position of accelerometer at housing.................. 50

Picture 12: Z- Axis, EUT 144305 – E, Test set-up resonance search ........................... 51

Picture 13: Z- Axis EUT 144305 – E, position of accelerometers .................................. 52

Picture 14: Z- Axis EUT 144305– E, position of accelerometer at housing ................... 53

Picture 15: Z- Axis, EUT 144305 –F, Test set-up resonance search ............................ 54

Picture 16: Z- Axis EUT 144305 – F, position of accelerometers .................................. 55

Picture 17: Z- Axis EUT 144305 – F, position of accelerometer at housing .................. 56

Picture 18: Z- Axis, EUT 144305 – G, Test set-up resonance search ........................... 57

Picture 19: Z- Axis EUT 144305 – G, position of accelerometers ................................. 58

Picture 20: Z- Axis EUT 144305 – G, position of accelerometer at housing ................. 59

Picture 21: X- Axis, EUT 144305 – A, Test set-up resonance search ........................... 60

Picture 22: X- Axis EUT 144305 – A, position of accelerometers ................................. 61

Picture 23: X- Axis EUT 144305 – A, position of accelerometer at housing .................. 62

Picture 24: X- Axis, EUT 144305 – B; C & D, Test set-up resonance search ............... 63

Picture 25: X- Axis EUT 144305 – B, position of accelerometers ................................. 64

Picture 26: X- Axis EUT 144305 – C, position of accelerometers, USB- Port ............... 65

Picture 27: X- Axis EUT 144305 – C, position of accelerometer at housing ................. 66

Picture 28: X- Axis EUT 144305 – D, position of accelerometers ................................. 67

Picture 29: X- Axis, EUT 144305 – E, Test set-up resonance search ........................... 68

Picture 30: X- Axis EUT 144305 – E, position of accelerometers ................................. 69

Page 144: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 144 of 147

Picture 31: X- Axis EUT 144305 – E, position of accelerometer at housing .................. 70

Picture 32: X- Axis, EUT 144305 – F, Test set-up resonance search ........................... 71

Picture 33: X- Axis EUT 144305 – F, position of accelerometers .................................. 72

Picture 34: X- Axis EUT 144305 – F, position of accelerometer at housing .................. 73

Picture 35: X- Axis, EUT 144305 – G, Test set-up resonance search .......................... 74

Picture 36: X- Axis EUT 144305 – G, position of accelerometers ................................. 75

Picture 37: X- Axis EUT 144305 – G, position of accelerometer at housing ................. 76

Picture 38: Y- Axis, EUT 144305 – A, Test set-up resonance search ........................... 77

Picture 39: Y- Axis EUT 144305 – A, position of accelerometers ................................. 78

Picture 40: Y- Axis EUT 144305 – A, position of accelerometer at housing .................. 79

Picture 41: Y- Axis, EUT 144305 – B; C & D, Test set-up resonance search ............... 80

Picture 42: Y- Axis EUT 144305 – B, position of accelerometers ................................. 81

Picture 43: Y- Axis EUT 144305 – B, position of accelerometer at housing .................. 82

Picture 44: Y- Axis EUT 144305 – C, position of accelerometers ................................. 83

Picture 45: Y- Axis EUT 144305 – D, position of accelerometers ................................. 84

Picture 46: Y- Axis EUT 144305 – D, position of accelerometer at housing ................. 85

Picture 47: Y- Axis, EUT 144305 – E, Test set-up resonance search ........................... 86

Picture 48: Y- Axis EUT 144305 – E, position of accelerometers ................................. 87

Picture 49: Y- Axis EUT 144305 – E, position of accelerometer at housing .................. 88

Picture 50: Y- Axis, EUT 144305 – F, Test set-up resonance search ........................... 89

Picture 51: Y- Axis EUT 144305 – F, position of accelerometers .................................. 90

Picture 52: Y- Axis EUT 144305 – F, position of accelerometer at housing .................. 91

Picture 53: Y- Axis, EUT 144305 – G, Test set-up resonance search .......................... 92

Picture 54: Y- Axis EUT 144305 – G, position of accelerometers ................................. 93

Picture 55: Y- Axis EUT 144305 – G, position of accelerometer at housing ................. 94

Picture 56: EUTs in climatic cabinet .............................................................................. 95

Picture 57: Monitoring during climatic tests ................................................................... 96

Picture 57: By the monitoring marked massages .......................................................... 97

Page 145: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 145 of 147

6 List of Diagrams

Diagram 1: Vibration, Resonance search profile (exemplary) ................................ 98

Diagram 2: Resonance search Z- Axis, EUT 144305 – A Housing ........................ 99

Diagram 3: Resonance search Z- Axis, EUT 144305 – A Ethernetport .................. 99

Diagram 4: Resonance search Z- Axis, EUT 144305 – A, Mounting plate fan ..... 100

Diagram 5: Resonance search Z- Axis, EUT 144305 – A, PCB ........................... 100

Diagram 6: Resonance search Z- Axis, EUT 144305 – B, PCB ........................... 101

Diagram 7: Resonance search Z- Axis, EUT 144305 – B, Housing ..................... 101

Diagram 8: Resonance search Z- Axis, EUT 144305 – C, PCB ........................... 102

Diagram 9: Resonance search Z- Axis, EUT 144305 – C, Housing ..................... 102

Diagram 10: Resonance search Z- Axis, EUT 144305 – D, PCB ........................... 103

Diagram 11: Resonance search Z- Axis, EUT 144305 – D, Housing ..................... 103

Diagram 12: Resonance search Z- Axis, EUT 144305 – E, USB- Port PCB .......... 104

Diagram 13: Resonance search Z- Axis, EUT 144305 – E, PCB ........................... 104

Diagram 14: Resonance search Z- Axis, EUT 144305 – E, AC filter ...................... 105

Diagram 15: Resonance search Z- Axis, EUT 144305 – E, Housing ..................... 105

Diagram 16: Resonance search Z- Axis, EUT 144305 – F, mounting plate fan ..... 106

Diagram 17: Resonance search Z- Axis, EUT 144305 – F, heat sink power supply ........................................................................................................... 106

Diagram 18: Resonance search Z- Axis, EUT 144305 – F, PCB center ................ 107

Diagram 19: Resonance search Z- Axis, EUT 144305 – F, Housing center........... 107

Diagram 20: Resonance search Z- Axis, EUT 144305 – G, Mounting plate fan..... 108

Diagram 21: Resonance search Z- Axis, EUT 144305 – G, PCB center ................ 108

Diagram 22: Resonance search Z- Axis, EUT 144305 – G, Housing center .......... 109

Diagram 23: Resonance search X- Axis, EUT 144305 – A, LED socket ................ 110

Diagram 24: Resonance search X- Axis, EUT 144305 – A, Battery socket ............ 110

Diagram 25: Resonance search X- Axis, EUT 144305 – A, AC- Filter ................... 111

Diagram 26: Resonance search X- Axis, EUT 144305 – A, Housing DVI .............. 111

Diagram 27: Resonance search X- Axis, EUT 144305 – A, Ethernet port .............. 112

Diagram 28: Resonance search X- Axis, EUT 144305 – B, Housing center .......... 113

Diagram 29: Resonance search X- Axis, EUT 144305 – B, PCB USB ................... 113

Page 146: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 146 of 147

Diagram 30: Resonance search X- Axis, EUT 144305 – C, Housing center .......... 114

Diagram 31: Resonance search X- Axis, EUT 144305 – C, PCB Ethernet port ..... 114

Diagram 32: Resonance search X- Axis, EUT 144305 – D, Housing center .......... 115

Diagram 33: Resonance search X- Axis, EUT 144305 – D, PCB ........................... 115

Diagram 34: Resonance search X- Axis, EUT 144305 – E, USB port .................... 116

Diagram 35: Resonance search X- Axis, EUT 144305 – E, Capacitor ................... 116

Diagram 36: Resonance search X- Axis, EUT 144305 – E, Housing center .......... 117

Diagram 37: Resonance search X- Axis, EUT 144305 – E, heat sink .................... 117

Diagram 38: Resonance search X- Axis, EUT 144305 – F, Coil ............................ 118

Diagram 39: Resonance search X- Axis, EUT 144305 – F, heat sink power module ........................................................................................................... 118

Diagram 40: Resonance search X- Axis, EUT 144305 – F, Housing center .......... 119

Diagram 41: Resonance search X- Axis, EUT 144305 – F, Capacitor main PCB .. 119

Diagram 42: Resonance search X- Axis, EUT 144305 – G, housing center .......... 120

Diagram 43: Resonance search X- Axis, EUT 144305 – G, PCB Power connector ........................................................................................................... 120

Diagram 44: Resonance search X- Axis, EUT 144305 – G, heat sink power module ........................................................................................................... 121

Diagram 45: Resonance search X- Axis, EUT 144305 – G, Capacitor main PCB .. 121

Diagram 46: Resonance search Y- Axis, EUT 144305 – A, Capacitor ................... 122

Diagram 47: Resonance search Y- Axis, EUT 144305 – A, fan ............................. 122

Diagram 48: Resonance search Y- Axis, EUT 144305 – A, Ethernet port .............. 123

Diagram 49: Resonance search Y- Axis, EUT 144305 – A, Housing center .......... 123

Diagram 50: Resonance search Y- Axis, EUT 144305 – B, USB port .................... 124

Diagram 51: Resonance search Y- Axis, EUT 144305 – B, housing center ........... 124

Diagram 52: Resonance search Y- Axis, EUT 144305 – C, Housing center .......... 125

Diagram 53: Resonance search Y- Axis, EUT 144305 – C, USB port .................... 125

Diagram 54: Resonance search Y- Axis, EUT 144305 – D, Ethernet port ............. 126

Diagram 55: Resonance search Y- Axis, EUT 144305 – D, Housing center .......... 126

Diagram 56: Resonance search Y- Axis, EUT 144305 – E, Ethernet port .............. 127

Diagram 57: Resonance search Y- Axis, EUT 144305 – E, AC- filter .................... 127

Diagram 58: Resonance search Y- Axis, EUT 144305 – E, heat sink power module ........................................................................................................... 128

Page 147: Test Report - Hatteland Technology...Test A: Cold / EN 60068-2-1; chapter 8.4.2.4, IEC 60945 This test determines the ability of equipment to be operated at low temperatures and also

Examiner: F. Nothnagel Test Report No.: U144305E1, 2nd VersionDate of issue: 16 September 2014 Order No.: 14-114305 Page 147 of 147

Diagram 59: Resonance search Y- Axis, EUT 144305 – E, housing center ........... 128

Diagram 60: Resonance search Y- Axis, EUT 144305 – F, capacitor main PCB ... 129

Diagram 61: Resonance search Y- Axis, EUT 144305 – F, Housing center .......... 129

Diagram 62: Resonance search Y- Axis, EUT 144305 – F, capacitor power module ........................................................................................................... 130

Diagram 63: Resonance search Y- Axis, EUT 144305 – G, Power out .................. 131

Diagram 64: Resonance search Y- Axis, EUT 144305 – G, AC- filter .................... 131

Diagram 65: Resonance search Y- Axis, EUT 144305 – G, fan ............................. 132

Diagram 66: Resonance search Y- Axis, EUT 144305 – G, housing center .......... 132

Diagram 67: Resonance search Y- Axis, EUT 144305 – G, heat sink .................... 133

Diagram 68: Resonance search X- Axis, EUT 144305 – H, Housing ..................... 134

Diagram 69: Resonance search Y- Axis, EUT 144305 – H, Housing ..................... 134

Diagram 70: Resonance search Z- Axis, EUT 144305 – H, Housing ..................... 135

Diagram 71: Resonance search X- Axis, EUT 144305 – W, Housing .................... 136

Diagram 72: Resonance search Y- Axis, EUT 144305 – W, Housing .................... 136

Diagram 73: Resonance search Z- Axis, EUT 144305 – W, Housing .................... 137

Diagram 74: Temperature profile, Dry heat storage ............................................... 138

Diagram 75: Temperature profile, Dry heat function............................................... 139

Diagram 76: Temperature profile, Low temperature function ................................. 140

Diagram 77: Climatic profile, Humidity, function ..................................................... 141

Diagram 78: Monitoring Audio Signal, Humidity, function (exemplary) ................... 142


Recommended