Test Report No. CANEC0805455703 Date: 15 Oct 2008 Page 1 of 5
SAMSON ENTERPRISES LIMITED
SHUITIAN ROAD, SHUILIUTIAN INDUSTRIAL DISTRIC, TONGLE, LONGGANG, SHENZHEN
CHINA
The following sample(s) was/were submitted and identified on behalf of the clients as :
IRON CORE (IRON POWDER)
SGS Job No. 11331000 - SZ :
SGS Internal Reference No. : 4.3
Date of Sample Received : 08 Oct 2008
Testing Period : 08 Oct 2008 - 14 Oct 2008
Test Requested : Selected test(s) as requested by client.
: Please refer to next page(s).Test Method
Test Results : Please refer to next page(s).
:Conclusion Based on the performed tests on submitted sample(s), the results comply
with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of
SGS-CSTC Ltd.
Sr. EngineerHuang Fang, Sunny
Test Report No. CANEC0805455703 Date: 15 Oct 2008 Page 2 of 5
Test Results:
:ID for specimen 1 CAN08-054557.002
Dk-grey ring :Description for specimen 1
RoHS Directive 2002/95/EC
MDL LimitResultUnit Test Method (Reference)Test Item(s)
100Cadmium (Cd) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Lead (Pb) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Mercury (Hg) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Hexavalent Chromium (CrVI) by
alkaline extraction
N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), UV-Vis
1000Sum of PBBs N.D.mg/kg --
Monobromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Dibromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tribromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tetrabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Pentabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Hexabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Heptabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Octabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Nonabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Decabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
1000Sum of PBDEs N.D.mg/kg --
Monobromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Dibromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tribromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tetrabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Pentabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Hexabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Heptabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Octabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Nonabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Decabromodiphenyl ether ## N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the
European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included in the sum of
PBDE after 01.07.2008
5. "-" = Not regulated
Test Report No. CANEC0805455703 Date: 15 Oct 2008 Page 3 of 5
Test Report No. CANEC0805455703 Date: 15 Oct 2008 Page 4 of 5
Test Report No. CANEC0805455703 Date: 15 Oct 2008 Page 5 of 5
Sample photo:
CANEC0805455703
CAN08-054557.002
SGS authenticate the photo on original report only
*** End of Report ***
Test Report
Report No. : KA/2008/B0466
Sample Description :
Sample Receiving Date :
Testing Period :
Test Result(s) : - Please see the next page(s) -
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
===================================================================================================
2008/11/06
2008/11/06 TO 2008/11/12
Page : 1 of 8Date : 2008/11/12
The following sample(s) was/were submitted and identified by/on behalf of the client as :
*KA-2008-B0466*
GREEN HIGH BUILD EPOXY RESIN PAINT (A+B)
Test Report
Page : 2 of 8
Test Result(s)
PART NAME NO.1 :
ResultNo. 1
Hexavalent Chromium Cr(VI) With reference to US EPA Method 3060A& 7196A for Hexavalent Chromium fornon-metallic samples. Analysis wasperformed by UV/Vis Spectrometry.
2 n.d.
Cadmium (Cd) With reference to US EPA Method 3052for Cadmium Content. Analysis wasperformed by ICP-AES.
2 n.d.
Mercury (Hg) With reference to US EPA Method 3052for Mercury Content. Analysis wasperformed by ICP-AES.
2 n.d.
Lead (Pb) With reference to US EPA Method 3052for Lead Content. Analysis was performedby ICP-AES.
2 n.d.
Phosphorus (P) With reference to US EPA 3052. Analysiswas performed by ICP-AES.
2 57.4
Antimony trioxide (Sb2O3)(CAS No.:1309-64-4)***
With reference to US EPA Method 3052for Antimony Content. Analysis wasperformed by ICP-AES.
2 n.d.
PERFLUOROOCTANOIC ACID(PFOA)
With reference to US EPA 3540C : 1996method for PFOA Content. Analysis wasperformed by LC/MS.
10 n.d.
PERFLUOROOCTANESULFONATES (PFOS)PFOS – AcidPFOS – Metal SaltPFOS – Amide
With reference to US EPA 3540C : 1996method for PFOS Content. Analysis wasperformed by LC/MS.
10 n.d.
GREEN HIGH BUILD EPOXY RESIN PAINT (A+B)
Test Item (s) Unit
Date : 2008/11/12
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
*KA-2008-B0466*
mg/kg
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
mg/kg
Method MDL
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
Page : 3 of 8
*KA-2008-B0466*
ResultNo. 1
Sum of PBBs - n.d.Monobromobiphenyl 5 n.d.Dibromobiphenyl 5 n.d.Tribromobiphenyl 5 n.d.Tetrabromobiphenyl 5 n.d.Pentabromobiphenyl 5 n.d.Hexabromobiphenyl 5 n.d.Heptabromobiphenyl 5 n.d.Octabromobiphenyl 5 n.d.Nonabromobiphenyl 5 n.d.Decabromobiphenyl 5 n.d.Sum of PBDEs - n.d.Monobromodiphenyl ether 5 n.d.Dibromodiphenyl ether 5 n.d.Tribromodiphenyl ether 5 n.d.Tetrabromodiphenyl ether 5 n.d.Pentabromodiphenyl ether 5 n.d.Hexabromodiphenyl ether 5 n.d.Heptabromodiphenyl ether 5 n.d.Octabromodiphenyl ether 5 n.d.Nonabromodiphenyl ether 5 n.d.Decabromodiphenyl ether 5 n.d.
Note: 1. mg/kg = ppm; 0.1wt% = 1000ppm2. n.d. = Not Detected3. MDL = Method Detection Limit4. The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled
in the sum of PBDE after 01.07.2008
by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included
5. " - " = Not Regulated6. ***The substance is calculated by the test results of Tributyl Tin or heavy metal (Ex. Antimony、
Beryllium、Silicon 、 Zinc、Cobalt or Phosphorus respectively). The MDL is evaluated for
Tributyl Tin or heavy metal (Ex. Antimony、Beryllium、Silicon 、 Zinc、Cobalt or Phosphorusrespectively.)
With reference to US EPA 3540C forPBBs/PBDEs Content. Analysis wasperformed by GC/MS.
mg/kg
With reference to US EPA 3540C forPBBs/PBDEs Content. Analysis wasperformed by GC/MS.
mg/kg
Test Item (s) Unit Method MDL
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
Page : 4 of 8
*KA-2008-B0466*
(2) May not be placed on the market in semi-finished products or articles, or parts thereof, if the
Please refer to KA/200X/XXXXX for original information.
15. This report supersedes all pervious documents bearing the test report number KA/200X/XXXXX.
PFOS Reference Information : 2006/122/EC (Directive 2006/122/EC)
16. This is the additional test report of KA/200X/XXXXX which was issued on yyyy/mm/dd.
(1) May not be placed on the market or used as a substance or constituent of preparations in a
concentration equal to or higher than 0,005 % by mass.
coated materials, if the amount of PFOS is equal to or higher than 1µg/m2 of the coated material.
concentration of PFOS is equal to or higher than 0,1 % by mass calculated with reference to the
mass of structurally or microstructurally distinct parts that contain PFOS or, for textiles or other
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
Page : 5 of 8
*KA-2008-B0466*
1) These samples were dissolved totally by pre-conditioning method according to below flow chart.(Cr6+ test
method excluded)
2) Name of the person who made measurement: Hungming Li
3) Name of the person in charge of measurement: Ray Chang
Cr6+
Sample Material Digestion Acid
Steel, copper, aluminum, solder Aqua regia, HNO3, HCl, HF, H2O2
Glass HNO3/HF
Gold, platinum, palladium, ceramic Aqua regia
Silver HNO3
Plastic H2SO4, H2O2, HNO3, HCl
Others Any acid to total digestion
Pb、Cd
Solution
ICP-AES
Acid digestion by suitable acid
depended on different sample
material (as below table)
Filtration
Residue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
Cutting / Preparation
Microwave digestion with
HNO3/HCl/HF
Heat to appropriate
temperature to extract
Cool, filter digestate
through filter
Add diphenyl-carbazide for
color development
measure the absorbance
at 540 nm by UV-VIS
Add appropriate amount of
digestion reagent
Hg
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
Page : 6 of 8
*KA-2008-B0466*
PBB/PBDE analytical FLOW CHART
1) Name of the person who made measurement: Anson Tsao
2) Name of the person in charge of measurement: Ray Chang
First testing process
Optional screen process
Confirmation process
Sample
Screen analysis
Issue Report
Sample pretreatment
Sample extraction/Soxhlet method
Concentrate/DiluteExtracted solution
Analysis by GC/MS
Filter
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0466
Page : 7 of 8
*KA-2008-B0466*
<END>
Analytical flow chart of PFOA/PFOS content
1) Name of the person who made measurement: Anson Tsao
2) Name of the person in charge of measurement: Ray Chang
Sample pretreatment
Sample extraction by Soxhlet extraction
(Reference method US EPA 3540)
Concentrate/Dilute Extracted solution
Analysis was performed by LC/MS
Data
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
** End of Report **
Page : 8 of 8
*KA-2008-B0466*
Report No. : KA/2008/B0466
Test Report
Report No. : KA/2008/B0465
Sample Description :
Sample Receiving Date :
Testing Period :
Test Result(s) : - Please see the next page(s) -
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
===================================================================================================
2008/11/06
2008/11/06 TO 2008/11/12
Page : 1 of 8Date : 2008/11/12
The following sample(s) was/were submitted and identified by/on behalf of the client as :
*KA-2008-B0465*
BLUE HIGH BUILD EPOXY RESIN PAINT (A+B)
Test Report
Page : 2 of 8
Test Result(s)
PART NAME NO.1 :
ResultNo. 1
Hexavalent Chromium Cr(VI) With reference to US EPA Method 3060A& 7196A for Hexavalent Chromium fornon-metallic samples. Analysis wasperformed by UV/Vis Spectrometry.
2 n.d.
Cadmium (Cd) With reference to US EPA Method 3052for Cadmium Content. Analysis wasperformed by ICP-AES.
2 n.d.
Mercury (Hg) With reference to US EPA Method 3052for Mercury Content. Analysis wasperformed by ICP-AES.
2 n.d.
Lead (Pb) With reference to US EPA Method 3052for Lead Content. Analysis was performedby ICP-AES.
2 n.d.
Phosphorus (P) With reference to US EPA 3052. Analysiswas performed by ICP-AES.
2 55.8
Antimony trioxide (Sb2O3)(CAS No.:1309-64-4)***
With reference to US EPA Method 3052for Antimony Content. Analysis wasperformed by ICP-AES.
2 n.d.
PERFLUOROOCTANOIC ACID(PFOA)
With reference to US EPA 3540C : 1996method for PFOA Content. Analysis wasperformed by LC/MS.
10 n.d.
PERFLUOROOCTANESULFONATES (PFOS)PFOS – AcidPFOS – Metal SaltPFOS – Amide
With reference to US EPA 3540C : 1996method for PFOS Content. Analysis wasperformed by LC/MS.
10 n.d.
BLUE HIGH BUILD EPOXY RESIN PAINT (A+B)
Test Item (s) Unit
Date : 2008/11/12
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
*KA-2008-B0465*
mg/kg
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
mg/kg
Method MDL
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
Page : 3 of 8
*KA-2008-B0465*
ResultNo. 1
Sum of PBBs - n.d.Monobromobiphenyl 5 n.d.Dibromobiphenyl 5 n.d.Tribromobiphenyl 5 n.d.Tetrabromobiphenyl 5 n.d.Pentabromobiphenyl 5 n.d.Hexabromobiphenyl 5 n.d.Heptabromobiphenyl 5 n.d.Octabromobiphenyl 5 n.d.Nonabromobiphenyl 5 n.d.Decabromobiphenyl 5 n.d.Sum of PBDEs - n.d.Monobromodiphenyl ether 5 n.d.Dibromodiphenyl ether 5 n.d.Tribromodiphenyl ether 5 n.d.Tetrabromodiphenyl ether 5 n.d.Pentabromodiphenyl ether 5 n.d.Hexabromodiphenyl ether 5 n.d.Heptabromodiphenyl ether 5 n.d.Octabromodiphenyl ether 5 n.d.Nonabromodiphenyl ether 5 n.d.Decabromodiphenyl ether 5 n.d.
Note: 1. mg/kg = ppm; 0.1wt% = 1000ppm2. n.d. = Not Detected3. MDL = Method Detection Limit4. The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled
in the sum of PBDE after 01.07.2008
by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included
5. " - " = Not Regulated6. ***The substance is calculated by the test results of Tributyl Tin or heavy metal (Ex. Antimony、
Beryllium、Silicon 、 Zinc、Cobalt or Phosphorus respectively). The MDL is evaluated for
Tributyl Tin or heavy metal (Ex. Antimony、Beryllium、Silicon 、 Zinc、Cobalt or Phosphorusrespectively.)
With reference to US EPA 3540C forPBBs/PBDEs Content. Analysis wasperformed by GC/MS.
mg/kg
With reference to US EPA 3540C forPBBs/PBDEs Content. Analysis wasperformed by GC/MS.
mg/kg
Test Item (s) Unit Method MDL
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
Page : 4 of 8
*KA-2008-B0465*
(2) May not be placed on the market in semi-finished products or articles, or parts thereof, if the
Please refer to KA/200X/XXXXX for original information.
15. This report supersedes all pervious documents bearing the test report number KA/200X/XXXXX.
PFOS Reference Information : 2006/122/EC (Directive 2006/122/EC)
16. This is the additional test report of KA/200X/XXXXX which was issued on yyyy/mm/dd.
(1) May not be placed on the market or used as a substance or constituent of preparations in a
concentration equal to or higher than 0,005 % by mass.
coated materials, if the amount of PFOS is equal to or higher than 1µg/m2 of the coated material.
concentration of PFOS is equal to or higher than 0,1 % by mass calculated with reference to the
mass of structurally or microstructurally distinct parts that contain PFOS or, for textiles or other
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
Page : 5 of 8
*KA-2008-B0465*
1) These samples were dissolved totally by pre-conditioning method according to below flow chart.(Cr6+ test
method excluded)
2) Name of the person who made measurement: Hungming Li
3) Name of the person in charge of measurement: Ray Chang
Cr6+
Sample Material Digestion Acid
Steel, copper, aluminum, solder Aqua regia, HNO3, HCl, HF, H2O2
Glass HNO3/HF
Gold, platinum, palladium, ceramic Aqua regia
Silver HNO3
Plastic H2SO4, H2O2, HNO3, HCl
Others Any acid to total digestion
Pb、Cd
Solution
ICP-AES
Acid digestion by suitable acid
depended on different sample
material (as below table)
Filtration
Residue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
Cutting / Preparation
Microwave digestion with
HNO3/HCl/HF
Heat to appropriate
temperature to extract
Cool, filter digestate
through filter
Add diphenyl-carbazide for
color development
measure the absorbance
at 540 nm by UV-VIS
Add appropriate amount of
digestion reagent
Hg
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
Page : 6 of 8
*KA-2008-B0465*
PBB/PBDE analytical FLOW CHART
1) Name of the person who made measurement: Anson Tsao
2) Name of the person in charge of measurement: Ray Chang
First testing process
Optional screen process
Confirmation process
Sample
Screen analysis
Issue Report
Sample pretreatment
Sample extraction/Soxhlet method
Concentrate/DiluteExtracted solution
Analysis by GC/MS
Filter
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
Report No. : KA/2008/B0465
Page : 7 of 8
*KA-2008-B0465*
<END>
Analytical flow chart of PFOA/PFOS content
1) Name of the person who made measurement: Anson Tsao
2) Name of the person in charge of measurement: Ray Chang
Sample pretreatment
Sample extraction by Soxhlet extraction
(Reference method US EPA 3540)
Concentrate/Dilute Extracted solution
Analysis was performed by LC/MS
Data
Test Report
Date : 2008/11/12
BERLIN (HUI-ZHOU) SCIENTIFIC CHEMICAL CO., LTD.
YUNG-SHI BLVD, SHI-WAN TOWN, PO-LO COUNTY HUI-ZHOU CITY,GUANGDONG, 516127 CHINA
** End of Report **
Page : 8 of 8
*KA-2008-B0465*
Report No. : KA/2008/B0465
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 1 of 8
CHANGYUAN ELECTRONICS(SHENZHEN)CO.,LTD
BID#30-4,SHENZHEN SCIENCE&TECHNOLOGY INDUSTRY PARK,NANSHAN,SHENZHEN
CHINA
The following sample(s) was/were submitted and identified on behalf of the clients as :
HEAT SHRINKABLE TUBE(BLACK)
SGS Job No. 11051058 - SZ :
SGS Internal Reference No. : 6.3
Model/P.O.No:HFT AND 102 :Client Reference Information
Item/Style/Ref.No.:HFT-080519-01-2
CHANGYUAN ELECTRONICS(SHENZHEN) CO.,LTD :Manufacturer
Date of Sample Received : 26 May 2008
Testing Period : 26 May 2008 - 30 May 2008
Test Requested : Selected test(s) as requested by client.
: Please refer to next page(s).Test Method
Test Results : Please refer to next page(s).
:Conclusion A: Based on the performed tests on submitted sample(s), the results comply
with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of
SGS-CSTC Ltd.
Sr. EngineerHuang Fang, Sunny
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 2 of 8
Test Results:
:ID for specimen 1 CAN08-026291.003
Black tube w/ white printing :Description for specimen 1
A: RoHS Directive 2002/95/EC
MDL LimitResultUnit Test MethodTest Item(s)
100Cadmium (Cd) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Lead (Pb) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Mercury (Hg) N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), ICP-OES
1000Hexavalent Chromium (CrVI) by
alkaline extraction
N.D.mg/kg 2IEC 62321/2nd CDV (111/95/CDV), UV-Vis
1000Sum of PBBs N.D.mg/kg --
Monobromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Dibromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tribromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tetrabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Pentabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Hexabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Heptabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Octabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Nonabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Decabromobiphenyl N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
1000Sum of PBDEs(Mono to Nona)
(Note 4)
N.D.mg/kg --
Monobromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Dibromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tribromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Tetrabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Pentabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Hexabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Heptabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Octabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Nonabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
Decabromodiphenyl ether N.D.mg/kg 5IEC 62321/2nd CDV (111/95/CDV), GC-MS
-Sum of PBDEs(Mono to Deca) N.D.mg/kg --
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. Sum of Mono to NonaBDE & according to 2005/717/EC DecaBDE is exempt.
5. "-" = Not regulated
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 3 of 8
Test Method MDLResultUnitTest Item(s)
B: Halogen
Fluorine (F) mg/kg BS EN 14582:2007, IC 156 50
Chlorine (Cl) mg/kg BS EN 14582:2007, IC N.D. 50
Bromine (Br) mg/kg BS EN 14582:2007, IC N.D. 50
Iodine (l) mg/kg BS EN 14582:2007, IC N.D. 50
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
Test Method MDLResultUnitTest Item(s)
C: PAHs (Polynuclear Aromatic Hydrocarbons)
Naphthalene mg/kg ZEK 01-08, GC-MS 0.5 0.2
Acenaphthylene mg/kg ZEK 01-08, GC-MS 0.3 0.2
Acenaphthene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Fluorene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Phenanthrene mg/kg ZEK 01-08, GC-MS 1.0 0.2
Anthracene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Fluoranthene mg/kg ZEK 01-08, GC-MS 0.9 0.2
Pyrene mg/kg ZEK 01-08, GC-MS 3.0 0.2
Benz(a)anthracene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Chrysene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Benzo(b)fluoranthene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Benzo(k)fluoranthene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Benzo(a)pyrene mg/kg ZEK 01-08, GC-MS 0.3 0.2
Indeno(1,2,3-cd)pyrene mg/kg ZEK 01-08, GC-MS 0.4 0.2
Dibenzo(a,h)anthracene mg/kg ZEK 01-08, GC-MS N.D. 0.2
Benzo(g,h,i)perylene mg/kg ZEK 01-08, GC-MS 1.5 0.2
Sum of 16 PAHs acc. US EPA mg/kg - 7.9 -
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 4 of 8
ZEK 01-08 : Restraining maximum values for products
Parameter
Benzo[a]pyrene
(mg/kg)
Sum 16 PAH (US EPA)
(mg/kg)**
Category 1
Material in contact with
foodstuff or materials which
are meant to put in the mouth
as well as toys for children
<36 months
Category 2
Materials with foreseeable
skin contact >30 s
(prolonged skin contact)
and toys not covered by
category 1
Category 3
Materials with foreseeable
skin contact <30 s (short
time skin contact) or without
skin contact
<MDL (<0.2)***
<MDL (<0.2)***
1 20
10 200
Remark : Only PAH substances >0.2 mg/kg are taken into account while calculating the sum of PAHs
In case that the maximum values exceed the limits of category 1, but are within the limits of
category 2, one may confirm the suitability of the tested material for contact with foodstuff or oral
mucosa by additional specific migration tests of PAH components based on DIN EN 1186ff and
§64 LFGB 80.30-1. The conclusion of the migration test results must be made based on food
law criteria.
** =
*** =
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 5 of 8
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 6 of 8
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 7 of 8
Test Report No. CANEC0802629103 Date: 30 May 2008 Page 8 of 8
Sample photo:
CANEC0802629103
CAN08-026291.003
SGS authenticate the photo on original report only
*** End of Report ***
Test Report No. CANEC0902971902 Date: 11 Jun 2009 Page 1 of 5
SHENZHEN YUANTONG INDUSTRY CO.,LTD.
NO.513 ROOM XILI NANSHAN DIST.SHENZHEN CITY,CHINA
The following sample(s) was/were submitted and identified on behalf of the clients as :
环保助焊剂
SGS Job No. 11863052 - SZ :
主要成份:酒精,异丙醇,稀释剂 :Client Reference Information
2.2 :SGS Internal Reference No.
Date of Sample Received : 08 Jun 2009
Testing Period : 08 Jun 2009 - 11 Jun 2009
Test Requested : Selected test(s) as requested by client.
: Please refer to next page(s).Test Method
Test Results : Please refer to next page(s).
:Conclusion Based on the performed tests on submitted sample(s), the results comply
with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of
SGS-CSTC Ltd.
Sunny HuangLab Sr. Supervisor
Test Report No. CANEC0902971902 Date: 11 Jun 2009 Page 2 of 5
Test Results:
:ID for specimen 1 CAN09-029719.002
Lt-yellow transparent liquid :Description for specimen 1
RoHS Directive 2002/95/EC
MDL LimitResultUnit Test Method (Reference)Test Item(s)
100Cadmium (Cd) N.D.mg/kg 2IEC 62321:2008, ICP-OES
1000Lead (Pb) N.D.mg/kg 2IEC 62321:2008, ICP-OES
1000Mercury (Hg) N.D.mg/kg 2IEC 62321:2008, ICP-OES
1000Hexavalent Chromium (CrVI) by
alkaline extraction
N.D.mg/kg 2IEC 62321:2008, UV-Vis
1000Sum of PBBs N.D.mg/kg --
Monobromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Dibromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Tribromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Tetrabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Pentabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Hexabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Heptabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Octabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Nonabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
Decabromobiphenyl N.D.mg/kg 5IEC 62321:2008, GC-MS
1000Sum of PBDEs N.D.mg/kg --
Monobromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Dibromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Tribromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Tetrabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Pentabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Hexabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Heptabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Octabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Nonabromodiphenyl ether N.D.mg/kg 5IEC 62321:2008, GC-MS
Decabromodiphenyl ether ## N.D.mg/kg 5IEC 62321:2008, GC-MS
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the
European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE is included in the sum of
PBDE after 01.07.2008
5. "-" = Not regulated
6. The result(s) of specimen is/are of the total weight of wet sample.
Test Report No. CANEC0902971902 Date: 11 Jun 2009 Page 3 of 5
Test Report No. CANEC0902971902 Date: 11 Jun 2009 Page 4 of 5
Test Report No. CANEC0902971902 Date: 11 Jun 2009 Page 5 of 5
Sample photo:
CANEC0902971902
CAN09-029719.002
SGS authenticate the photo on original report only
*** End of Report ***
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
:
:
:
:
測試需求(Test Requested) :
測試方法(Test Method)
測試結果(Test Results)
測試期間(Testing Period)
2009/05/27
2009/05/27 TO 2009/06/04
:
===================================================================================================================
參照 RoHS 2002/95/EC 及其修定指令要求. (In accordance with the RoHS
Directive 2002/95/EC, and its amendment directives).
請見下一頁 (Please refer to next pages).
*KA/2009/51643A-01*岱暉電子化學股份有限公司
收件日期(Sample Receiving Date)
DYFENCO ELECTRONIC CHEMICAL CORP.
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
樣品型號(Style/Item No.)
號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 1 of 7
無鉛銲錫 LEAD FREE SOLDER
無鉛銲錫-D9930C/SN100 (LEAD FREE SOLDER D9930C/SN100)
(82446)高雄縣燕巢鄉角宿村四林路136號
測試報告
Test Report
以下測試樣品係由客戶送樣, 且由客戶聲稱並經客戶確認如下 (The following samples was/were submitted and
identified by/on behalf of the client as):
樣品名稱(Sample Description)
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
測試方法(Test Method) :
(1)
(2)
(3)
(4)
(5)
測試結果(Test Results) :
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
用感應藕合電漿原子發射光譜儀(ICP-AES)檢測鉛含量. / Determination of
Lead by ICP-AES.
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
DYFENCO ELECTRONIC CHEMICAL CORP.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
(82446)高雄縣燕巢鄉角宿村四林路136號
以氣相層析/質譜儀(GC/MS)檢測多溴聯苯和多溴聯苯醚含量. /
Determination of PBB and PBDE by GC/MS.
參考IEC 62321:2008方法檢測. (With reference to IEC 62321:2008. Procedures
for the Determination of Levels of Regulated Substances in
Electrotechnical Products).
用感應藕合電漿原子發射光譜儀(ICP-AES)檢測鎘含量. / Determination of
Cadmium by ICP-AES.
請見下一頁 (Please refer to next pages).
用感應藕合電漿原子發射光譜儀(ICP-AES)檢測汞含量. / Determination of
Mercury by ICP-AES.
測試報告
Test Report號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 2 of 7
岱暉電子化學股份有限公司 *KA/2009/51643A-01*
針對金屬材質之樣品, 用Spot test / boiling water extraction方法檢測
六價鉻含量. / Determination of Hexavalent Chromium for metallic
samples by Spot test / boiling water extraction Method.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
結果 (Result)
No.1
(1) n.d. 2
(2) 63.4 2
(3) n.d. 2
(4) Negative See Note 4
n.d. -
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. -
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
n.d. 5
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
岱暉電子化學股份有限公司 *KA/2009/51643A-01*
DYFENCO ELECTRONIC CHEMICAL CORP.
(82446)高雄縣燕巢鄉角宿村四林路136號
測試報告
Test Report
八溴聯苯醚 / Octabromodiphenyl ether
七溴聯苯 / Heptabromobiphenyl
八溴聯苯 / Octabromobiphenyl
九溴聯苯 / Nonabromobiphenyl
十溴聯苯 / Decabromobiphenyl
二溴聯苯醚 / Dibromodiphenyl ether
一溴聯苯醚 / Monobromodiphenyl ether
汞 / Mercury (Hg)
鎘 / Cadmium (Cd)
鉛 / Lead (Pb)
測試項目
(Test Items)
五溴聯苯醚 / Pentabromodiphenyl ether
六溴聯苯醚 / Hexabromodiphenyl ether
九溴聯苯醚 / Nonabromodiphenyl ether
十溴聯苯醚 / Decabromodiphenyl ether
七溴聯苯醚 / Heptabromodiphenyl ether
多溴聯苯總和 / Sum of PBBs
一溴聯苯 / Monobromobiphenyl
號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 3 of 7
六價鉻 / Hexavalent Chromium Cr(VI) by
Spot test / boiling water extraction
測試方法
Method
(Refer to)
測試結果(Test Results) 單位(Unit): mg/kg
方法偵測
極限值
(MDL)
六溴聯苯 / Hexabromobiphenyl
三溴聯苯 / Tribromobiphenyl
四溴聯苯 / Tetrabromobiphenyl
五溴聯苯 / Pentabromobiphenyl
四溴聯苯醚 / Tetrabromodiphenyl ether
(5)
三溴聯苯醚 / Tribromodiphenyl ether
多溴聯苯醚總和 / Sum of PBDEs
二溴聯苯 / Dibromobiphenyl
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
備註(Note):
1. mg/kg = ppm;0.1wt% = 1000ppm
2. n.d. = Not Detected (未檢出)
3. MDL = Method Detection Limit (方法偵測極限值)
4. Spot-test:
Negative = Absence of Cr(VI) coating / surface layer(鍍層中偵測不到六價鉻),
Positive = Presence of Cr(VI) coating / surface layer(鍍層中偵測到六價鉻);
The tested sample should be further verified by boiling-water-extraction method if the
spot test result cannot be confirmed.
(當該測項無法確認時, 測試樣品可藉由boiling-water-extraction測試方法進一步確認)
Boiling-water-extraction:
Negative = Absence of Cr(VI) coating / surface layer(鍍層中偵測不到六價鉻),
Positive = Presence of Cr(VI) coating / surface layer(鍍層中偵測到六價鉻);
the detected concentration in boiling-water-extraction solution is equal or
greater than 0.02 mg/kg with 50 cm2 sample surface area.
該溶液濃度≧0.02 mg/kg with 50 cm2 (sample surface area)
5.歐洲共同體法院2008年4月1日已經駁回2005/717/EC中針對十溴聯苯醚可在塑膠中
使用的排外條款,該項隨後將會自2008年7月1日起列於各項溴聯苯醚分析數值總括計算中
The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled
by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will
be included in the sum of PBDE after 01.07.2008
6. "-" = Not Regulated (無規格值)
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
測試部位描述 (TEST PART DESCRIPTION):
NO.1 : 銀色/SILVER 無鉛銲錫 LEAD FREE SOLDER
岱暉電子化學股份有限公司
(82446)高雄縣燕巢鄉角宿村四林路136號
*KA/2009/51643A-01*
DYFENCO ELECTRONIC CHEMICAL CORP.
測試報告
Test Report號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 4 of 7
7. 此為2009/06/04所發行KA/2009/51643之加發報告,原始資料請參考KA/2009/51643。
This is the additional test report of KA/2009/51643 which was issued on 2009/06/04.
Please refer to KA/2009/51643 for original information.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
測試報告
Test Report號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 5 of 7
岱暉電子化學股份有限公司 *KA/2009/51643A-01*
DYFENCO ELECTRONIC CHEMICAL CORP.
(82446)高雄縣燕巢鄉角宿村四林路136號
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
岱暉電子化學股份有限公司 *KA/2009/51643A-01*
DYFENCO ELECTRONIC CHEMICAL CORP.
(82446)高雄縣燕巢鄉角宿村四林路136號
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
測試報告
Test Report號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 6 of 7
多溴聯苯/多溴聯苯醚分析流程圖 / PBB/PBDE analytical FLOW CHART
1)測試人員:曹嘉琪 / Name of the person who made measurement: Anson Tsao
2)測試負責人:張伯睿 / Name of the person in charge of measurement: Ray Chang
初次測試程序 / First testing process
選擇性篩檢程序 / Optional screen process
確認程序 / Confirmation process
Sample / 樣品
Issue Report 撰打報告
Sample extraction 樣品萃取/
Soxhlet method 索式萃取法
Analysis by GC/MS氣相層析質譜儀分析
Filter 萃取液過濾
Sample pretreatment / 樣品前處理
Screen analysis / 初篩分析
Concentrate/Dilute Extracted solution萃取液濃縮/稀釋
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。 This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd. No. 61, Kai-Fa Road, Nanzih Export Processing Zone, Kaohsiung, Taiwan. / 高雄市楠梓加工出口區開發路 61 號 台灣檢驗科技股份有限公司 t (886-7) 301-2121 f (886-7) 301-0867 www.tw.sgs.com
Member of SGS Group
NO.136, SU LIN ROAD, YENCHAO HSIANG, KAOHSIUNG HSIEN,TAIWAN.
永金金屬材料(東莞)有限公司/蘇州岱暉電子貿易公司
東莞市長安鎮街口村橫崗頭工業區/蘇州市吳中經濟開發區南湖路125號金月工業小區
測試報告
Test Report號碼(No.): KA/2009/51643A-01 日期(Date): 2009/06/10 頁數(Page): 7 of 7
DYFENCO ELECTRONIC CHEMICAL CORP.
(82446)高雄縣燕巢鄉角宿村四林路136號
** 報告結尾(End of Report) **
岱暉電子化學股份有限公司 *KA/2009/51643A-01*