49
Report No085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name Industrial GSM/GPRS Modem Model No. OnCell G2110, OnCell G2110-T Applicant Moxa Inc. Address Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, Taiwan, R.O.C. Date of Receipt 2008/05/21 Issued Date 2008/06/16 Report No. 085319R-HPCEP01V01 Version V2.0 The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Quie Tek Corporation.
Transcript
Page 1: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 1 of 49

Test Report

Product Name : Industrial GSM/GPRS Modem

Model No. : OnCell G2110, OnCell G2110-T

Applicant : Moxa Inc.

Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien

City, Taipei, Taiwan, R.O.C.

Date of Receipt : 2008/05/21

Issued Date : 2008/06/16

Report No. : 085319R-HPCEP01V01

Version : V2.0

The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Quie Tek Corporation.

Page 2: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 2 of 49

Test Report Cert i f icat ion Issued Date: 2008/06/16

Report No: 085319R-HPCEP01V01

Product Name : Industrial GSM/GPRS Modem

Applicant : Moxa Inc.

Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,

Taipei, Taiwan, R.O.C.

Manufacturer : Moxa Inc.

Model No. : OnCell G2110, OnCell G2110-T

Rated Voltage : AC 230 V / 50 Hz

EUT Voltage : DC 12V-48V

Trade Name : Moxa

Measurement

Standard

: EN 301489-1: V1.6.1 (2005-09)

EN 301489-7: V1.3.1 (2005-11)

Measurement

Procedure

: EN 55022:2006+A1: 2000+A2: 2003

EN 61000-3-2: 2000+ A2: 2005

EN 61000-3-3: 1995+A1: 2001

EN 61000-4-2:1995+A1: 1998+ A2: 2001

EN 61000-4-3:2002+A1: 2002

EN 61000-4-4:2004

EN 61000-4-5:1995+A1: 2001

EN 61000-4-6:1996+A1: 2001

EN 61000-4-11:1994+A1: 2001

Test Result : Complied The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Quie Tek Corporation.

Documented By :

( E n g i n e e r i n g A d m . A s s i s t a n t/ N i c o l e H u a n g )

Tested By :

( E n g i n e e r / N o N o C h a n g ) Approved By :

( D e p u t y M a n a g e r / V i n c e n t L i n )

Page 3: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 3 of 49

TABLE OF CONTENTS

Description Page 1. General Information .................................................................................................................5

1.1. EUT Description ............................................................................................................. 5

1.2. Test Mode....................................................................................................................... 6

1.3. Tested System Details .................................................................................................... 7

1.4. Configuration of tested System ...................................................................................... 7

1.5. EUT Exercise Software .................................................................................................. 8

1.6. Test Facility..................................................................................................................... 9 2. Radiated Emission .................................................................................................................10

2.1. Test Equipment List ...................................................................................................... 10

2.2. Test Setup .................................................................................................................... 10

2.3. Limits ............................................................................................................................ 11

2.4. Test Procedure ............................................................................................................. 11

2.5. Test Specification.......................................................................................................... 11

2.6. Uncertainty ................................................................................................................... 11

2.7. Test Result....................................................................................................................12

2.8. Test Photo .................................................................................................................... 14 3. Electrostatic Discharge (ESD).............................................................................................15

3.1. Test Equipment List ...................................................................................................... 15

3.2. Test Setup .................................................................................................................... 15

3.3. Limits ............................................................................................................................ 16

3.4. Test Procedure ............................................................................................................. 16

3.5. Test Specification.......................................................................................................... 16

3.6. Uncertainty ................................................................................................................... 16

3.7. Test Result....................................................................................................................17

3.8. Test Photo .................................................................................................................... 18 4. Radiated Susceptibility (RS)................................................................................................19

4.1. Test Equipment List ...................................................................................................... 19

4.2. Test Setup .................................................................................................................... 20

4.3. Limits ............................................................................................................................ 20

4.4. Test Procedure ............................................................................................................. 21

4.5. Test Specification.......................................................................................................... 21

4.6. Uncertainty ................................................................................................................... 21

Page 4: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 4 of 49

4.7. Test Result....................................................................................................................22

4.8. Test Photo .................................................................................................................... 26 5. Electrical Fast Transient/Burst (EFT/B) ............................................................................27

5.1. Test Equipment List ...................................................................................................... 27

5.2. Test Setup .................................................................................................................... 27

5.3. Limits ............................................................................................................................ 28

5.4. Test Procedure ............................................................................................................. 28

5.5. Test Specification.......................................................................................................... 28

5.6. Uncertainty ................................................................................................................... 28

5.7. Test Result....................................................................................................................29

5.8. Test Photo .................................................................................................................... 30 6. Surge..........................................................................................................................................31

6.1. Test Equipment List ...................................................................................................... 31

6.2. Test Setup .................................................................................................................... 31

6.3. Limits ............................................................................................................................ 32

6.4. Test Procedure ............................................................................................................. 32

6.5. Test Specification.......................................................................................................... 32

6.6. Uncertainty ................................................................................................................... 32

6.7. Test Result....................................................................................................................33

6.8. Test Photo .................................................................................................................... 34 7. Conducted Susceptibility (CS)............................................................................................35

7.1. Test Equipment List ...................................................................................................... 35

7.2. Test Setup .................................................................................................................... 35

7.3. Limits ............................................................................................................................ 36

7.4. Test Procedure ............................................................................................................. 36

7.5. Test Specification.......................................................................................................... 37

7.6. Uncertainty ................................................................................................................... 37

7.7. Test Result....................................................................................................................38

7.8. Test Photo .................................................................................................................... 40

Attachement ................................................................................................................. 41

  EUT Photograph........................................................................................................... 41 Reference: Laboratory of License

Page 5: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 5 of 49

1. General Information

1.1. EUT Description

Product Name Industrial GSM/GPRS Modem

Trade Name Moxa

Model No. OnCell G2110, OnCell G2110-T

Antenna Type Fixed

TX Frequency GSM:890 ~ 915 MHz , DCS:1710 ~ 1785 MHz

Rx Frequency GSM:935 ~ 960 MHz , DCS:1805 ~1880 MHz

Note: The different of each model is shown as below:

OnCell G2110: Have no function of wide temperate range.

OnCell G2110-T: Have function of wide temperate range.

The model of OnCell G2110-T was tested.

Component

Antenna Cable Non-Shielded, 4.5m

RS-232 Cable Non-Shielded, 1.85m

DC Power Cord Non-Shielded, 2.5m

Page 6: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 6 of 49

1.2. Test Mode

Quie Tek has verified the construction and function in typical operation. All the test modes were

carried out with the EUT in normal operation, which was shown in this test report and defined as:

Pre-Test Mode Limit Results EMI Mode 1: GSM 900 GPRS Link

Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Class B Pass

Final Test Mode Limit Results RE Mode 1: GSM 900 GPRS Link

Mode 3: DCS 1800 GPRS Link Class B Pass

Final Test Mode Performance Criteria

Performance Criteria

Results

ESD Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

TT, TR B Pass

RS Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link

CT, CR A Pass

CS Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link

CT, CR A Pass

EFT/ Surge Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

TT, TR B Pass

Note: Performance criteria

The performance criteria are used to take a decision on whether a radio equipment passes or fails

immunity tests.

Four categories of performance criteria apply:

Performance criteria for Continuous phenomena applied to Transmitters (CT):

Performance criteria for Continuous phenomena applied to Receiver (CR):

Performance criteria for Transient phenomena applied to Transmitters (TT):

Performance criteria for Transient phenomena applied to Receiver (TR):

Additionally, three performance criteria apply:

Criteria A : Operate as intended during and after the test.

Criteria B : Operate as intended after the test.

Criteria C : Loss/Error of function.

Page 7: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 7 of 49

1.3. Tested System Details

The types for all equipments, plus descriptions of all cables used in the tested system

(including inserted cards) are:

Product Manufacturer Model No. Serial No. Power Cord

1 Notebook DELL PP18L 42649348672 N/A

2 DPS GW GPC-6030D D921006 N/A

1.4. Configuration of tested System

Test Mode Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Connection Diagram

Signal Cable Type Signal cable Description

A RS-232 Cable Non-Shielded, 1.85m

B DC Power Cord Non-Shielded, 2.5m

Page 8: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 8 of 49

1.5. EUT Exercise Software

(1) Setup the EUT and simulators as shown on 1.4.

(2) Turn on the power of all equipments.

(3) The EUT was set to communicate with CMU200.

(4) Repeat the above procedure (3).

Page 9: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 9 of 49

1.6. Test Facility

Ambient conditions in the laboratory:

Items Test Item Required (IEC 68-1) Actual

Temperature (C) IEC 61000-4-2 15-35 20-35

Humidity (%RH) 30-60 50-55

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) IEC 61000-4-3 15-35 20-35

Humidity (%RH) 10-75 50-65

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) IEC 61000-4-4 15-35 20-35

Humidity (%RH) 30-60 50-55

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) IEC 61000-4-5 15-35 20-35

Humidity (%RH) 10-75 50-65

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) IEC 61000-4-6 15-35 20-35

Humidity (%RH) 30-60 50-55

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) IEC 61000-4-11 15-35 20-35

Humidity (%RH) 25-75 50-65

Barometric pressure (mbar) 860-1060 950-1000

Site Description: Accredited by NVLAP NVLAP Lab Code: 200533-0 Accredited by DNV Statement No. : 413-99-LAB11 Accredited by TUV Rheinland Certificate No.: 10011438-1-2004

Accredited by Nemko Certificate No.: ELA 165

Accredited by TAF Accredited Number: 0914 Site Name: Quietek Corporation Site Address: No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]

Page 10: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 10 of 49

2. Radiated Emission

2.1. Test Equipment List

The following test equipments are used during the radiated emission test:

Test Site Equipment Manufacturer Model No./ Serial No. Last Cal.

Bilog Antenna Schaffner Chase CBL6112B/ 2918 Sep., 2007

Broadband Horn

Antenna

Schwarzbeck BBHA9170/ 208 Jul., 2007

EMI Test Receiver R&S ESCS 30/ 100122 Feb., 2008

Horn Antenna Schwarzbeck BBHA9120D/ 305 Oct., 2007

Pre-Amplifier QTK N/A Jan., 2008

OATS 1

Spectrum

Analyzer

Advantest R3162/ 100803470 Nov., 2007

Note: 1. All equipments that need to be calibrated are with calibration period of 1 year. 2. Mark “X” test instruments are used to measure the final test results.

2.2. Test Setup

Page 11: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 11 of 49

2.3. Limits

EN 55022 Limits (dBuV/m)

Class A Class B Frequency

MHz Distance (m) dBuV/m

Distance (m) dBuV/m

30 – 230 10 40 10 30

230 – 1000 10 47 10 37

Remarks: In the above table, the tighter limit applies at the band edges.

2.4. Test Procedure

The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.

The turn table can rotate 360 degrees to determine the position of the maximum emission

level. The EUT was positioned such that the distance from antenna to the EUT was 10

meters.

The antenna can move up and down between 1 meter and 4 meters to find out the

maximum emission level.

Both horizontal and vertical polarization of the antenna are set on measurement. In order

to find the maximum emission, all of the interface cables must be manipulated according

to EN 55022: 1998+ A1: 2000+ A2: 2003 on radiated measurement.

Radiated emissions were investigated over the frequency range from 30MHz to1GHz

using a receiver bandwidth of 120kHz. Radiated measurement was performed at an

antenna to EUT distance of 10 meters.

2.5. Test Specification

According to EN 55022: 1998+ A1: 2000+ A2: 2003

2.6. Uncertainty

The measurement uncertainty is defined as ± 3.8 dB

Page 12: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 12 of 49

2.7. Test Result

Product Industrial GSM/GPRS Modem

Test Mode Mode 1: GSM 900 GPRS Link

Date of Test 2008/05/27 Test Range 0.15-30MHz

Test Condition Radiated Emission Environment 25C, 50%RH

Frequency Correct Reading Measurement Margin Limit

Factor Level Level

MHz dB dBuV dBuV/m dB dBuV/m

Horizontal

34.850 16.431 17.079 33.510 -6.490 40.000

78.500 8.234 10.436 18.670 -21.330 40.000

175.500 11.313 7.377 18.690 -21.310 40.000

214.300 11.324 8.736 20.060 -19.940 40.000

369.500 19.010 4.400 23.410 -23.590 47.000

517.420 22.768 2.912 25.680 -21.320 47.000

Frequency Correct Reading Measurement Margin Limit

Factor Level Level

MHz dB dBuV dBuV/m dB dBuV/m

Vertical

34.850 16.431 15.609 32.040 -7.960 40.000

78.500 8.234 10.386 18.620 -21.380 40.000

180.360 11.014 9.406 20.420 -19.580 40.000

214.300 11.324 6.616 17.940 -22.060 40.000

257.900 15.979 6.401 22.380 -24.620 47.000

517.420 22.768 3.402 26.170 -20.830 47.000

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. “ ”, means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 13: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 13 of 49

Product Industrial GSM/GPRS Modem

Test Mode Mode 3: DCS 1800 GPRS Link

Date of Test 2008/05/27 Test Range 0.15-30MHz

Test Condition Radiated Emission Environment 25C, 50%RH

Frequency Correct Reading Measurement Margin Limit

Factor Level Level

MHz dB dBuV dBuV/m dB dBuV/m

Horizontal

37.200 15.164 15.856 31.020 -8.980 40.000

80.920 8.692 9.628 18.320 -21.680 40.000

177.920 11.141 8.429 19.570 -20.430 40.000

207.020 11.644 7.017 18.660 -21.340 40.000

451.950 21.148 3.472 24.620 -22.380 47.000

612.000 24.443 2.397 26.840 -20.160 47.000

Frequency Correct Reading Measurement Margin Limit

Factor Level Level

MHz dB dBuV dBuV/m dB dBuV/m

Vertical

34.850 16.431 13.649 30.080 -9.920 40.000

180.350 11.014 6.966 17.980 -22.020 40.000

204.600 11.676 7.944 19.620 -20.380 40.000

260.370 16.158 5.482 21.640 -25.360 47.000

379.200 19.313 4.697 24.010 -22.990 47.000

544.100 23.888 1.982 25.870 -21.130 47.000

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. “ ”, means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 14: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 14 of 49

2.8. Test Photo

Test Mode: Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link

Description: Front View of Radiated Test

Description: Back View of Radiated Test

Page 15: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 15 of 49

3. Electrostatic Discharge (ESD)

3.1. Test Equipment List

Item Instrument Manufacturer Type No/Serial No. Last

Calibration

1 ESD Simulator System EM TEST

dito

S/N: V0635101749

Sep., 2007

2 Horizontal Coupling Plane(HCP) QuieTek HCP AL50 N/A

3 Vertical Coupling Plane(VCP) QuieTek VCP AL50 N/A

4 No.3 Shielded Room N/A

Note: All equipments upon which need to be calibrated are with calibration period of 1 year.

3.2. Test Setup

Page 16: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 16 of 49

3.3. Limits

Item Environmental Phenomena

Units Test Specification Performance Criteria

Performance Criteria

Enclosure Port

Electrostatic Discharge KV (Charge Voltage) ±8 Air Discharge

±4 Contact Discharge

TT,TR B

Remark:

The Contact discharges were applied – at least total 200 discharges at a minimum of four test

points.

3.4. Test Procedure

Direct application of discharges to the EUT:

Contact discharge was applied only to conductive surfaces of the EUT.

Air discharges were applied only to non-conductive surfaces of the EUT.

During the test, it was performed with single discharges. For the single discharge

time between successive single discharges will be keep longer 1 second. It was at

least ten single discharges with positive and negative at the same selected point.

The selected point, which was performed with electrostatic discharge, was marked

on the red label of the EUT.

Indirect application of discharges to the EUT:

Vertical Coupling Plane (VCP):

The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned

at a distance 0.1m from, the EUT, with the Discharge Electrode touching the

coupling plane.

The four faces of the EUT will be performed with electrostatic discharge. It was at

least ten single discharges with positive and negative at the same selected point.

Horizontal Coupling Plane (HCP):

The coupling plane is placed under to the EUT. The generator shall be positioned

vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching

the coupling plane.

The four faces of the EUT will be performed with electrostatic discharge. It was at

least ten single discharges with positive and negative at the same selected point.

3.5. Test Specification

According to EN 61000-4-2: 1995+ A1: 1998+ A2: 2001

3.6. Uncertainty

The measurement uncertainty is defined as ± 6.003 %

Page 17: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 17 of 49

3.7. Test Result

Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link

Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Date of Test 2008/06/02 Environment 23C, 52%RH, 987mbar

Test Condition ESD Test Range

Item Amount of

Discharge Voltage Complied To

Criteria Results

Air Discharge

10

10

10

±2kV

±4kV

±8kV

A

A

A

Pass

Pass

Pass

Contact Discharge 25

25

±2kV

±4kV

A

A

Pass

Pass

Indirect Discharge

(HCP)

50

50

±2kV

±4kV

A

A

Pass

Pass

Indirect Discharge

(VCP Front)

50

50

±2kV

±4kV

A

A

Pass

Pass

Indirect Discharge

(VCP Left)

50

50

±2kV

±4kV

A

A

Pass

Pass

Indirect Discharge

(VCP Back)

50

50

±2kV

±4kV

A

A

Pass

Pass

Indirect Discharge

(VCP Right)

50

50

±2kV

±4kV

A

A

Pass

Pass

Remark:

The Contact discharges were applied-at least total 200 discharges at a minimum of

four test points.

Additional Information

EUT stopped operation and could / could not be reset by operator at

kV of Line .

No false alarms or other malfunctions were observed during or after the test.

Page 18: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 18 of 49

3.8. Test Photo

Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Description: ESD Test Setup

Page 19: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 19 of 49

4. Radiated Susceptibility (RS)

4.1. Test Equipment List

Item Equipment Manufacturer Model No./ Serial No. Last Cal.

1 Signal Generator R & S SML03/ 1033301 Aug., 2007

2 Universal Radio

Communication Tester R & S CMU200/ 104846 Apr., 2008

3 Audio Analyzer R & S UPL / 100137 Apr., 2008

4 Mouth Simulator B & K Type 4227/ 2439692 Aug., 2007

5 Dual Microphone

Supply B & K Type 5935/ 2426784 Aug., 2007

6 Probe Microphone B & K Type 4182/ 2278070 Aug., 2007

7 1/2 Microphone

Preamplifier B & K Type 2669/ 2426609 Aug., 2007

8 Power Amplifier A & R 100W10000M7/ A285000010

N/A

9 Power Amplifier A & R 25S1G4A / 308598 N/A

10 Biconilog Antenna EMCO 3149/ 00071675 May., 2008

11 Power Meter R & S NRVD/ 100219 Apr., 2008

12 Directional Coupler A & R DC6180/ 22735 N/A

13 No.5 EMC Fully Chamber N/A

Note: All equipments upon which need to be calibrated are with calibration period of 1 year.

Page 20: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 20 of 49

4.2. Test Setup

4.3. Limits

Item Environmental Phenomena

Units Test Specification

Enclosure Port

Radio-Frequency Electromagnetic Field Amplitude Modulated

MHz V/m(Un-modulated, rms) % AM (1kHz)

80-1000 1400-2000 3 80

Limits Performance Criteria

Uplink speech level<reference level-35dB Downlink speech level<reference level-35dBRXQUAL≦3

CT,CR

Page 21: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 21 of 49

4.4. Test Procedure

The EUT and load, which are placed on a table that is 0.8 meter above ground, are

placed with one coincident with the calibration plane such that the distance from antenna

to the EUT was 3 meters.

Both horizontal and vertical polarization of the antenna and six sides of the EUT are set

on measurement.

All the scanning conditions are as follows:

Condition of Test Remarks

EN 61000-4-3

1. Field Strength 3 V/m Level 2

2. Radiated Signal AM 80% Modulated with 1kHz

3. Scanning Frequency 80MHz - 1000MHz

1400MHz - 2000MHz

4. Dwell Time 3 Seconds

5. Frequency step size f : 1%

6. The rate of Swept of Frequency 1.5 x 10-3 decades/s

4.5. Test Specification

According to EN301489-7 & EN 61000-4-3:1995+ A1: 1998+ A2: 2001

4.6. Uncertainty

The measurement uncertainty is defined as ± 6.17 %

Page 22: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 22 of 49

4.7. Test Result

Product Industrial GSM/GPRS Modem

Test Mode Mode 1: GSM 900 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition Horizontal Test Range 80-1000MHz & 1400-2000MHz

Page 23: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 23 of 49

Product Industrial GSM/GPRS Modem

Test Mode Mode 1: GSM 900 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition Vertical Test Range 80-1000MHz & 1400-2000MHz

Page 24: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 24 of 49

Product Industrial GSM/GPRS Modem

Test Mode Mode 3: DCS 1800 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition Horizontal Test Range 80-1000MHz & 1400-2000MHz

Page 25: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 25 of 49

Product Industrial GSM/GPRS Modem

Test Mode Mode 3: DCS 1800 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition Vertical Test Range 80-1000MHz & 1400-2000MHz

Page 26: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 26 of 49

4.8. Test Photo

Test Mode : Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link

Description: Radiated Susceptibility Test Setup

Page 27: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 27 of 49

5. Electrical Fast Transient/Burst (EFT/B)

5.1. Test Equipment List

Instrument Manufacturer Type No. Serial No Cal. Date

Schaffner NSG 2050

System Mainframe

N/A N/A N/A Dec., 2007

EMC immunity system Thermo N/A 411225 Dec., 2007

Note: All equipments upon which need to be calibrated are with calibration period of 1 year.

5.2. Test Setup

Page 28: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 28 of 49

5.3. Limits

Item Environmental Phenomena

Units Test Specification Performance Criteria

Performance Criteria

Signal Ports and Telecommunication Ports

Fast Transients Common Mode

KV (Peak) Tr/Ts ns Rep. Frequency kHz

±0.5 5/50 5

TT,TR B

Input DC Power Ports

Fast Transients Common Mode

KV (Peak) Tr/Ts ns Rep. Frequency kHz

±0.5 5/50 5

TT,TR B

Input AC Power Ports

Fast Transients Common Mode

KV (Peak) Tr/Ts ns Rep. Frequency kHz

±1 5/50 5

TT,TR B

5.4. Test Procedure

The EUT and load are placed on a table that is 0.8 meter above a metal ground plane

measured 1m*1m min. and 0.65mm thick min. and projected beyond the EUT by at least

0.1m on all sides.

For Signal Ports and Telecommunication Ports:

The EFT interference signal through a coupling clamp device couples to the signal

and control lines of the EUT with burst noise for 1min.

For Input DC and AC Power Ports:

The EUT is connected to the power mains through a coupling device that directly

couples the EFT interference signal.

Each of the Line and Neutral conductors is impressed with burst noise for 1 min.

The length of power cord between the coupling device and the EUT shall be 1m.

5.5. Test Specification

According to EN 61000-4-4:1995+ A1: 2001

5.6. Uncertainty

The measurement uncertainty is defined as ± 8.80 %

Page 29: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 29 of 49

5.7. Test Result

Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link

Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Date of Test 2008/04/03 Environment 23C, 52%RH

Test Condition EFT/B

Inject

Line Polarity

Voltage

kV

Inject

Time

(Second)

Inject

Method

Complied

to

Criteria Result

L-N ± 1kV 60 Direct A PASS

Additional Information

EUT stopped operation and could / could not be reset by operator at

kV of Line .

No false alarms or other malfunctions were observed during or after the test.

Page 30: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 30 of 49

5.8. Test Photo

Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Description: EFT/B Test Setup

Page 31: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 31 of 49

6. Surge

6.1. Test Equipment List

Instrument Manufacturer Type No. Serial No Cal. Date

Schaffner NSG 2050

System Mainframe Schaffner N/A N/A Dec., 2007

Surge test Noiseken LSS-15AX N/A Nov., 2007

Note: All equipments upon which need to be calibrated are with calibration period of 1 year.

6.2. Test Setup

Page 32: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 32 of 49

6.3. Limits

Item Environmental Phenomena

Units Test Specification Performance Criteria

Performance Criteria

Signal Ports and Telecommunication Ports (See 1) and 2))

Surges Line to Ground

Tr/Ts uS KV

1.2/50 (8/20) 1 TT,TR B

Input DC Power Ports

Surges Line to Ground

Tr/Ts uS KV

1.2/50 (8/20) 0.5 TT,TR B

AC Input and AC Output Power Ports

Surges Line to Line Line to Ground

Tr/Ts uS KV KV

1.2/50 (8/20) 1 2

TT,TR B

Notes:

1) Applicable only to ports which according to the manufacturer’s may directly to outdoor

cables.

2) Where normal functioning cannot be achieved because of the impact of the CDN on the

EUT, no test shall be required.

6.4. Test Procedure

The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane

measured 1m*1m min. and 0.65mm thick min. and projected beyond the EUT by at least 0.1m

on all sides. The length of power cord between the coupling device and the EUT shall be 2m

or less.

For Input and Output AC Power or DC Input and DC Output Power Ports:

The EUT is connected to the power mains through a coupling device that directly couples

the surge interference signal.

The surge noise shall be applied synchronized to the voltage phase at 00, 900, 1800, 2700

and the peak value of the ac. voltage wave. (Positive and negative)

Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with

interval of 1 min.

6.5. Test Specification

According to EN 61000-4-5:1995+ A1: 2001

6.6. Uncertainty

The measurement uncertainty is defined as ± 7.93 %

Page 33: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 33 of 49

6.7. Test Result

Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link

Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition Surge

Inject

Line Polarity Angle

Voltage

kV

Time

Interval

(Second)

Inject

Method

Complied

to

Criteria Result

L-N ± 0 1kV 60 Direct A PASS

L-N ± 90 1kV 60 Direct A PASS

L-N ± 180 1kV 60 Direct A PASS

L-N ± 270 1kV 60 Direct A PASS

Additional Information

EUT stopped operation and could / could not be reset by operator at kV of

Line .

No false alarms or other malfunctions were observed during or after the test.

Page 34: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 34 of 49

6.8. Test Photo

Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle

Description: SURGE Test Setup

Page 35: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 35 of 49

7. Conducted Susceptibility (CS)

7.1. Test Equipment List

Item Equipment Manufacturer Model No./ Serial No. Last Cal. 1 Signal Generator R & S SYM02/ 825454/ 029 Sep., 2007

2 Universal Radio Communication Tester

R & S CMU200/ 104846 Apr., 2008

3 Audio Analyzer R & S UPL / 100137 Apr., 2008 4 Mouth Simulator B & K Type 4227/ 2439692 Aug., 2007

5 Dual Microphone Supply

B & K Type 5935/ 2426784 Aug., 2007

6

Probe Microphone B & K Type 4182/ 2278070 Aug., 2007

7 1/2 Microphone Preamplifier

B & K Type 2669/ 2426609 Aug., 2007

8 Power Amplifier A & R 100W10000M7/ A285000010

N/A

9 Power Amplifier A & R 150A220/ 23067 N/A 10 Power Meter R & S NRVD/ 100219 Apr., 2008 11 Directional Coupler A & R DC2600/ 1007850-501 N/A 12 CDN Lüthi CDN L-801 M2/M3 / 2043 Jun., 2008 13 No.5 EMC Fully Chamber N/A

Note: All equipments upon which need to be calibrated are with calibration period of 1 year.

7.2. Test Setup

Page 36: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 36 of 49

7.3. Limits

Item Environmental

Phenomena Units Test

Specification

Enclosure Port

Radio-Frequency Electromagnetic Field Amplitude Modulated

MHz V (rms, Un-modulated) % AM (1kHz)

0.15-80 3 80

Limits Performance Criteria

Uplink speech level<reference level-35dB Downlink speech level<reference level-35dBRXQUAL≦3

CT,CR

7.4. Test Procedure

The EUT is placed on a table that is 0.8 meter height, and a ground reference plane is

placed on table and use a 10cm insulation between the EUT and ground reference plane.

For Signal Ports and Telecommunication Ports

The disturbance signal through a coupling and decoupling networks (CDN) or EM-clamp

device couples the signal to the telecommunication lines of the EUT.

For Input DC and AC Power Ports

The EUT is connected to the power mains through a coupling and decoupling networks for

power supply lines. And CDN-M2 for two wires or CDN-M3 for three wires was used directly

to couple the disturbances signal into EUT.

All the scanning conditions are as follows:

Condition of Test Remarks

1. Field Strength 130dBuV(3V) Level 2

2. Radiated Signal AM 80% Modulated with 1kHz

3. Scanning Frequency 0.15MHz – 80MHz

4. Dwell Time 3 Seconds

5. Frequency step size f : 1%

6. The rate of Swept of Frequency 1.5 x 10-3 decades/s

.

Page 37: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 37 of 49

7.5. Test Specification

According to EN 61000-4-6: 1996+ A1: 2001

7.6. Uncertainty

The measurement uncertainty is defined as ± 6.17 %

Page 38: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 38 of 49

7.7. Test Result

Product Industrial GSM/GPRS Modem

Test Mode Mode 1: GSM 900 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition CS Test Range 0.15-80MHz

Page 39: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 39 of 49

Product Industrial GSM/GPRS Modem

Test Mode Mode 3: DCS 1800 GPRS Link

Date of Test 2008/05/27 Environment 23C, 52%RH

Test Condition CS Test Range 0.15-80MHz

Page 40: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 40 of 49

7.8. Test Photo

Test Mode : Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link

Description: Conducted Susceptibility Test Setup

Page 41: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 41 of 49

Attachement

EUT Photograph

(1) EUT Photo

(2) EUT Photo

Page 42: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 42 of 49

(3) EUT Photo

(4) EUT Photo

Page 43: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 43 of 49

(5) EUT Photo

(6) EUT Photo

Page 44: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 44 of 49

(7) EUT Photo

(8) EUT Photo

Page 45: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 45 of 49

(9) EUT Photo

(10) EUT Photo

Page 46: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 46 of 49

(11) EUT Photo

(12) EUT Photo

Page 47: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 47 of 49

(13) EUT Photo

(14) EUT Photo

Page 48: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 48 of 49

(15) EUT Photo

(16) EUT Photo

Page 49: Test Report - Elmarksupport.elmark.com.pl/moxa/products/Modemy_GSM/OnCell...Report No:085319R-HPCEP01V01 Page: 1 of 49 Test Report Product Name : Industrial GSM/GPRS Modem Model

Report No:085319R-HPCEP01V01

Page: 49 of 49

Reference: Laboratory of License


Recommended