Report No:085319R-HPCEP01V01
Page: 1 of 49
Test Report
Product Name : Industrial GSM/GPRS Modem
Model No. : OnCell G2110, OnCell G2110-T
Applicant : Moxa Inc.
Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien
City, Taipei, Taiwan, R.O.C.
Date of Receipt : 2008/05/21
Issued Date : 2008/06/16
Report No. : 085319R-HPCEP01V01
Version : V2.0
The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Quie Tek Corporation.
Report No:085319R-HPCEP01V01
Page: 2 of 49
Test Report Cert i f icat ion Issued Date: 2008/06/16
Report No: 085319R-HPCEP01V01
Product Name : Industrial GSM/GPRS Modem
Applicant : Moxa Inc.
Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,
Taipei, Taiwan, R.O.C.
Manufacturer : Moxa Inc.
Model No. : OnCell G2110, OnCell G2110-T
Rated Voltage : AC 230 V / 50 Hz
EUT Voltage : DC 12V-48V
Trade Name : Moxa
Measurement
Standard
: EN 301489-1: V1.6.1 (2005-09)
EN 301489-7: V1.3.1 (2005-11)
Measurement
Procedure
: EN 55022:2006+A1: 2000+A2: 2003
EN 61000-3-2: 2000+ A2: 2005
EN 61000-3-3: 1995+A1: 2001
EN 61000-4-2:1995+A1: 1998+ A2: 2001
EN 61000-4-3:2002+A1: 2002
EN 61000-4-4:2004
EN 61000-4-5:1995+A1: 2001
EN 61000-4-6:1996+A1: 2001
EN 61000-4-11:1994+A1: 2001
Test Result : Complied The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Quie Tek Corporation.
Documented By :
( E n g i n e e r i n g A d m . A s s i s t a n t/ N i c o l e H u a n g )
Tested By :
( E n g i n e e r / N o N o C h a n g ) Approved By :
( D e p u t y M a n a g e r / V i n c e n t L i n )
Report No:085319R-HPCEP01V01
Page: 3 of 49
TABLE OF CONTENTS
Description Page 1. General Information .................................................................................................................5
1.1. EUT Description ............................................................................................................. 5
1.2. Test Mode....................................................................................................................... 6
1.3. Tested System Details .................................................................................................... 7
1.4. Configuration of tested System ...................................................................................... 7
1.5. EUT Exercise Software .................................................................................................. 8
1.6. Test Facility..................................................................................................................... 9 2. Radiated Emission .................................................................................................................10
2.1. Test Equipment List ...................................................................................................... 10
2.2. Test Setup .................................................................................................................... 10
2.3. Limits ............................................................................................................................ 11
2.4. Test Procedure ............................................................................................................. 11
2.5. Test Specification.......................................................................................................... 11
2.6. Uncertainty ................................................................................................................... 11
2.7. Test Result....................................................................................................................12
2.8. Test Photo .................................................................................................................... 14 3. Electrostatic Discharge (ESD).............................................................................................15
3.1. Test Equipment List ...................................................................................................... 15
3.2. Test Setup .................................................................................................................... 15
3.3. Limits ............................................................................................................................ 16
3.4. Test Procedure ............................................................................................................. 16
3.5. Test Specification.......................................................................................................... 16
3.6. Uncertainty ................................................................................................................... 16
3.7. Test Result....................................................................................................................17
3.8. Test Photo .................................................................................................................... 18 4. Radiated Susceptibility (RS)................................................................................................19
4.1. Test Equipment List ...................................................................................................... 19
4.2. Test Setup .................................................................................................................... 20
4.3. Limits ............................................................................................................................ 20
4.4. Test Procedure ............................................................................................................. 21
4.5. Test Specification.......................................................................................................... 21
4.6. Uncertainty ................................................................................................................... 21
Report No:085319R-HPCEP01V01
Page: 4 of 49
4.7. Test Result....................................................................................................................22
4.8. Test Photo .................................................................................................................... 26 5. Electrical Fast Transient/Burst (EFT/B) ............................................................................27
5.1. Test Equipment List ...................................................................................................... 27
5.2. Test Setup .................................................................................................................... 27
5.3. Limits ............................................................................................................................ 28
5.4. Test Procedure ............................................................................................................. 28
5.5. Test Specification.......................................................................................................... 28
5.6. Uncertainty ................................................................................................................... 28
5.7. Test Result....................................................................................................................29
5.8. Test Photo .................................................................................................................... 30 6. Surge..........................................................................................................................................31
6.1. Test Equipment List ...................................................................................................... 31
6.2. Test Setup .................................................................................................................... 31
6.3. Limits ............................................................................................................................ 32
6.4. Test Procedure ............................................................................................................. 32
6.5. Test Specification.......................................................................................................... 32
6.6. Uncertainty ................................................................................................................... 32
6.7. Test Result....................................................................................................................33
6.8. Test Photo .................................................................................................................... 34 7. Conducted Susceptibility (CS)............................................................................................35
7.1. Test Equipment List ...................................................................................................... 35
7.2. Test Setup .................................................................................................................... 35
7.3. Limits ............................................................................................................................ 36
7.4. Test Procedure ............................................................................................................. 36
7.5. Test Specification.......................................................................................................... 37
7.6. Uncertainty ................................................................................................................... 37
7.7. Test Result....................................................................................................................38
7.8. Test Photo .................................................................................................................... 40
Attachement ................................................................................................................. 41
EUT Photograph........................................................................................................... 41 Reference: Laboratory of License
Report No:085319R-HPCEP01V01
Page: 5 of 49
1. General Information
1.1. EUT Description
Product Name Industrial GSM/GPRS Modem
Trade Name Moxa
Model No. OnCell G2110, OnCell G2110-T
Antenna Type Fixed
TX Frequency GSM:890 ~ 915 MHz , DCS:1710 ~ 1785 MHz
Rx Frequency GSM:935 ~ 960 MHz , DCS:1805 ~1880 MHz
Note: The different of each model is shown as below:
OnCell G2110: Have no function of wide temperate range.
OnCell G2110-T: Have function of wide temperate range.
The model of OnCell G2110-T was tested.
Component
Antenna Cable Non-Shielded, 4.5m
RS-232 Cable Non-Shielded, 1.85m
DC Power Cord Non-Shielded, 2.5m
Report No:085319R-HPCEP01V01
Page: 6 of 49
1.2. Test Mode
Quie Tek has verified the construction and function in typical operation. All the test modes were
carried out with the EUT in normal operation, which was shown in this test report and defined as:
Pre-Test Mode Limit Results EMI Mode 1: GSM 900 GPRS Link
Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Class B Pass
Final Test Mode Limit Results RE Mode 1: GSM 900 GPRS Link
Mode 3: DCS 1800 GPRS Link Class B Pass
Final Test Mode Performance Criteria
Performance Criteria
Results
ESD Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
TT, TR B Pass
RS Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link
CT, CR A Pass
CS Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link
CT, CR A Pass
EFT/ Surge Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
TT, TR B Pass
Note: Performance criteria
The performance criteria are used to take a decision on whether a radio equipment passes or fails
immunity tests.
Four categories of performance criteria apply:
Performance criteria for Continuous phenomena applied to Transmitters (CT):
Performance criteria for Continuous phenomena applied to Receiver (CR):
Performance criteria for Transient phenomena applied to Transmitters (TT):
Performance criteria for Transient phenomena applied to Receiver (TR):
Additionally, three performance criteria apply:
Criteria A : Operate as intended during and after the test.
Criteria B : Operate as intended after the test.
Criteria C : Loss/Error of function.
Report No:085319R-HPCEP01V01
Page: 7 of 49
1.3. Tested System Details
The types for all equipments, plus descriptions of all cables used in the tested system
(including inserted cards) are:
Product Manufacturer Model No. Serial No. Power Cord
1 Notebook DELL PP18L 42649348672 N/A
2 DPS GW GPC-6030D D921006 N/A
1.4. Configuration of tested System
Test Mode Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Connection Diagram
Signal Cable Type Signal cable Description
A RS-232 Cable Non-Shielded, 1.85m
B DC Power Cord Non-Shielded, 2.5m
Report No:085319R-HPCEP01V01
Page: 8 of 49
1.5. EUT Exercise Software
(1) Setup the EUT and simulators as shown on 1.4.
(2) Turn on the power of all equipments.
(3) The EUT was set to communicate with CMU200.
(4) Repeat the above procedure (3).
Report No:085319R-HPCEP01V01
Page: 9 of 49
1.6. Test Facility
Ambient conditions in the laboratory:
Items Test Item Required (IEC 68-1) Actual
Temperature (C) IEC 61000-4-2 15-35 20-35
Humidity (%RH) 30-60 50-55
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C) IEC 61000-4-3 15-35 20-35
Humidity (%RH) 10-75 50-65
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C) IEC 61000-4-4 15-35 20-35
Humidity (%RH) 30-60 50-55
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C) IEC 61000-4-5 15-35 20-35
Humidity (%RH) 10-75 50-65
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C) IEC 61000-4-6 15-35 20-35
Humidity (%RH) 30-60 50-55
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C) IEC 61000-4-11 15-35 20-35
Humidity (%RH) 25-75 50-65
Barometric pressure (mbar) 860-1060 950-1000
Site Description: Accredited by NVLAP NVLAP Lab Code: 200533-0 Accredited by DNV Statement No. : 413-99-LAB11 Accredited by TUV Rheinland Certificate No.: 10011438-1-2004
Accredited by Nemko Certificate No.: ELA 165
Accredited by TAF Accredited Number: 0914 Site Name: Quietek Corporation Site Address: No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]
Report No:085319R-HPCEP01V01
Page: 10 of 49
2. Radiated Emission
2.1. Test Equipment List
The following test equipments are used during the radiated emission test:
Test Site Equipment Manufacturer Model No./ Serial No. Last Cal.
Bilog Antenna Schaffner Chase CBL6112B/ 2918 Sep., 2007
Broadband Horn
Antenna
Schwarzbeck BBHA9170/ 208 Jul., 2007
EMI Test Receiver R&S ESCS 30/ 100122 Feb., 2008
Horn Antenna Schwarzbeck BBHA9120D/ 305 Oct., 2007
Pre-Amplifier QTK N/A Jan., 2008
OATS 1
Spectrum
Analyzer
Advantest R3162/ 100803470 Nov., 2007
Note: 1. All equipments that need to be calibrated are with calibration period of 1 year. 2. Mark “X” test instruments are used to measure the final test results.
2.2. Test Setup
Report No:085319R-HPCEP01V01
Page: 11 of 49
2.3. Limits
EN 55022 Limits (dBuV/m)
Class A Class B Frequency
MHz Distance (m) dBuV/m
Distance (m) dBuV/m
30 – 230 10 40 10 30
230 – 1000 10 47 10 37
Remarks: In the above table, the tighter limit applies at the band edges.
2.4. Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.
The turn table can rotate 360 degrees to determine the position of the maximum emission
level. The EUT was positioned such that the distance from antenna to the EUT was 10
meters.
The antenna can move up and down between 1 meter and 4 meters to find out the
maximum emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order
to find the maximum emission, all of the interface cables must be manipulated according
to EN 55022: 1998+ A1: 2000+ A2: 2003 on radiated measurement.
Radiated emissions were investigated over the frequency range from 30MHz to1GHz
using a receiver bandwidth of 120kHz. Radiated measurement was performed at an
antenna to EUT distance of 10 meters.
2.5. Test Specification
According to EN 55022: 1998+ A1: 2000+ A2: 2003
2.6. Uncertainty
The measurement uncertainty is defined as ± 3.8 dB
Report No:085319R-HPCEP01V01
Page: 12 of 49
2.7. Test Result
Product Industrial GSM/GPRS Modem
Test Mode Mode 1: GSM 900 GPRS Link
Date of Test 2008/05/27 Test Range 0.15-30MHz
Test Condition Radiated Emission Environment 25C, 50%RH
Frequency Correct Reading Measurement Margin Limit
Factor Level Level
MHz dB dBuV dBuV/m dB dBuV/m
Horizontal
34.850 16.431 17.079 33.510 -6.490 40.000
78.500 8.234 10.436 18.670 -21.330 40.000
175.500 11.313 7.377 18.690 -21.310 40.000
214.300 11.324 8.736 20.060 -19.940 40.000
369.500 19.010 4.400 23.410 -23.590 47.000
517.420 22.768 2.912 25.680 -21.320 47.000
Frequency Correct Reading Measurement Margin Limit
Factor Level Level
MHz dB dBuV dBuV/m dB dBuV/m
Vertical
34.850 16.431 15.609 32.040 -7.960 40.000
78.500 8.234 10.386 18.620 -21.380 40.000
180.360 11.014 9.406 20.420 -19.580 40.000
214.300 11.324 6.616 17.940 -22.060 40.000
257.900 15.979 6.401 22.380 -24.620 47.000
517.420 22.768 3.402 26.170 -20.830 47.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. “ ”, means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor
Report No:085319R-HPCEP01V01
Page: 13 of 49
Product Industrial GSM/GPRS Modem
Test Mode Mode 3: DCS 1800 GPRS Link
Date of Test 2008/05/27 Test Range 0.15-30MHz
Test Condition Radiated Emission Environment 25C, 50%RH
Frequency Correct Reading Measurement Margin Limit
Factor Level Level
MHz dB dBuV dBuV/m dB dBuV/m
Horizontal
37.200 15.164 15.856 31.020 -8.980 40.000
80.920 8.692 9.628 18.320 -21.680 40.000
177.920 11.141 8.429 19.570 -20.430 40.000
207.020 11.644 7.017 18.660 -21.340 40.000
451.950 21.148 3.472 24.620 -22.380 47.000
612.000 24.443 2.397 26.840 -20.160 47.000
Frequency Correct Reading Measurement Margin Limit
Factor Level Level
MHz dB dBuV dBuV/m dB dBuV/m
Vertical
34.850 16.431 13.649 30.080 -9.920 40.000
180.350 11.014 6.966 17.980 -22.020 40.000
204.600 11.676 7.944 19.620 -20.380 40.000
260.370 16.158 5.482 21.640 -25.360 47.000
379.200 19.313 4.697 24.010 -22.990 47.000
544.100 23.888 1.982 25.870 -21.130 47.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. “ ”, means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor
Report No:085319R-HPCEP01V01
Page: 14 of 49
2.8. Test Photo
Test Mode: Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link
Description: Front View of Radiated Test
Description: Back View of Radiated Test
Report No:085319R-HPCEP01V01
Page: 15 of 49
3. Electrostatic Discharge (ESD)
3.1. Test Equipment List
Item Instrument Manufacturer Type No/Serial No. Last
Calibration
1 ESD Simulator System EM TEST
dito
S/N: V0635101749
Sep., 2007
2 Horizontal Coupling Plane(HCP) QuieTek HCP AL50 N/A
3 Vertical Coupling Plane(VCP) QuieTek VCP AL50 N/A
4 No.3 Shielded Room N/A
Note: All equipments upon which need to be calibrated are with calibration period of 1 year.
3.2. Test Setup
Report No:085319R-HPCEP01V01
Page: 16 of 49
3.3. Limits
Item Environmental Phenomena
Units Test Specification Performance Criteria
Performance Criteria
Enclosure Port
Electrostatic Discharge KV (Charge Voltage) ±8 Air Discharge
±4 Contact Discharge
TT,TR B
Remark:
The Contact discharges were applied – at least total 200 discharges at a minimum of four test
points.
3.4. Test Procedure
Direct application of discharges to the EUT:
Contact discharge was applied only to conductive surfaces of the EUT.
Air discharges were applied only to non-conductive surfaces of the EUT.
During the test, it was performed with single discharges. For the single discharge
time between successive single discharges will be keep longer 1 second. It was at
least ten single discharges with positive and negative at the same selected point.
The selected point, which was performed with electrostatic discharge, was marked
on the red label of the EUT.
Indirect application of discharges to the EUT:
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned
at a distance 0.1m from, the EUT, with the Discharge Electrode touching the
coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at
least ten single discharges with positive and negative at the same selected point.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching
the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at
least ten single discharges with positive and negative at the same selected point.
3.5. Test Specification
According to EN 61000-4-2: 1995+ A1: 1998+ A2: 2001
3.6. Uncertainty
The measurement uncertainty is defined as ± 6.003 %
Report No:085319R-HPCEP01V01
Page: 17 of 49
3.7. Test Result
Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link
Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Date of Test 2008/06/02 Environment 23C, 52%RH, 987mbar
Test Condition ESD Test Range
Item Amount of
Discharge Voltage Complied To
Criteria Results
Air Discharge
10
10
10
±2kV
±4kV
±8kV
A
A
A
Pass
Pass
Pass
Contact Discharge 25
25
±2kV
±4kV
A
A
Pass
Pass
Indirect Discharge
(HCP)
50
50
±2kV
±4kV
A
A
Pass
Pass
Indirect Discharge
(VCP Front)
50
50
±2kV
±4kV
A
A
Pass
Pass
Indirect Discharge
(VCP Left)
50
50
±2kV
±4kV
A
A
Pass
Pass
Indirect Discharge
(VCP Back)
50
50
±2kV
±4kV
A
A
Pass
Pass
Indirect Discharge
(VCP Right)
50
50
±2kV
±4kV
A
A
Pass
Pass
Remark:
The Contact discharges were applied-at least total 200 discharges at a minimum of
four test points.
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV of Line .
No false alarms or other malfunctions were observed during or after the test.
Report No:085319R-HPCEP01V01
Page: 18 of 49
3.8. Test Photo
Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Description: ESD Test Setup
Report No:085319R-HPCEP01V01
Page: 19 of 49
4. Radiated Susceptibility (RS)
4.1. Test Equipment List
Item Equipment Manufacturer Model No./ Serial No. Last Cal.
1 Signal Generator R & S SML03/ 1033301 Aug., 2007
2 Universal Radio
Communication Tester R & S CMU200/ 104846 Apr., 2008
3 Audio Analyzer R & S UPL / 100137 Apr., 2008
4 Mouth Simulator B & K Type 4227/ 2439692 Aug., 2007
5 Dual Microphone
Supply B & K Type 5935/ 2426784 Aug., 2007
6 Probe Microphone B & K Type 4182/ 2278070 Aug., 2007
7 1/2 Microphone
Preamplifier B & K Type 2669/ 2426609 Aug., 2007
8 Power Amplifier A & R 100W10000M7/ A285000010
N/A
9 Power Amplifier A & R 25S1G4A / 308598 N/A
10 Biconilog Antenna EMCO 3149/ 00071675 May., 2008
11 Power Meter R & S NRVD/ 100219 Apr., 2008
12 Directional Coupler A & R DC6180/ 22735 N/A
13 No.5 EMC Fully Chamber N/A
Note: All equipments upon which need to be calibrated are with calibration period of 1 year.
Report No:085319R-HPCEP01V01
Page: 20 of 49
4.2. Test Setup
4.3. Limits
Item Environmental Phenomena
Units Test Specification
Enclosure Port
Radio-Frequency Electromagnetic Field Amplitude Modulated
MHz V/m(Un-modulated, rms) % AM (1kHz)
80-1000 1400-2000 3 80
Limits Performance Criteria
Uplink speech level<reference level-35dB Downlink speech level<reference level-35dBRXQUAL≦3
CT,CR
Report No:085319R-HPCEP01V01
Page: 21 of 49
4.4. Test Procedure
The EUT and load, which are placed on a table that is 0.8 meter above ground, are
placed with one coincident with the calibration plane such that the distance from antenna
to the EUT was 3 meters.
Both horizontal and vertical polarization of the antenna and six sides of the EUT are set
on measurement.
All the scanning conditions are as follows:
Condition of Test Remarks
EN 61000-4-3
1. Field Strength 3 V/m Level 2
2. Radiated Signal AM 80% Modulated with 1kHz
3. Scanning Frequency 80MHz - 1000MHz
1400MHz - 2000MHz
4. Dwell Time 3 Seconds
5. Frequency step size f : 1%
6. The rate of Swept of Frequency 1.5 x 10-3 decades/s
4.5. Test Specification
According to EN301489-7 & EN 61000-4-3:1995+ A1: 1998+ A2: 2001
4.6. Uncertainty
The measurement uncertainty is defined as ± 6.17 %
Report No:085319R-HPCEP01V01
Page: 22 of 49
4.7. Test Result
Product Industrial GSM/GPRS Modem
Test Mode Mode 1: GSM 900 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition Horizontal Test Range 80-1000MHz & 1400-2000MHz
Report No:085319R-HPCEP01V01
Page: 23 of 49
Product Industrial GSM/GPRS Modem
Test Mode Mode 1: GSM 900 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition Vertical Test Range 80-1000MHz & 1400-2000MHz
Report No:085319R-HPCEP01V01
Page: 24 of 49
Product Industrial GSM/GPRS Modem
Test Mode Mode 3: DCS 1800 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition Horizontal Test Range 80-1000MHz & 1400-2000MHz
Report No:085319R-HPCEP01V01
Page: 25 of 49
Product Industrial GSM/GPRS Modem
Test Mode Mode 3: DCS 1800 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition Vertical Test Range 80-1000MHz & 1400-2000MHz
Report No:085319R-HPCEP01V01
Page: 26 of 49
4.8. Test Photo
Test Mode : Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link
Description: Radiated Susceptibility Test Setup
Report No:085319R-HPCEP01V01
Page: 27 of 49
5. Electrical Fast Transient/Burst (EFT/B)
5.1. Test Equipment List
Instrument Manufacturer Type No. Serial No Cal. Date
Schaffner NSG 2050
System Mainframe
N/A N/A N/A Dec., 2007
EMC immunity system Thermo N/A 411225 Dec., 2007
Note: All equipments upon which need to be calibrated are with calibration period of 1 year.
5.2. Test Setup
Report No:085319R-HPCEP01V01
Page: 28 of 49
5.3. Limits
Item Environmental Phenomena
Units Test Specification Performance Criteria
Performance Criteria
Signal Ports and Telecommunication Ports
Fast Transients Common Mode
KV (Peak) Tr/Ts ns Rep. Frequency kHz
±0.5 5/50 5
TT,TR B
Input DC Power Ports
Fast Transients Common Mode
KV (Peak) Tr/Ts ns Rep. Frequency kHz
±0.5 5/50 5
TT,TR B
Input AC Power Ports
Fast Transients Common Mode
KV (Peak) Tr/Ts ns Rep. Frequency kHz
±1 5/50 5
TT,TR B
5.4. Test Procedure
The EUT and load are placed on a table that is 0.8 meter above a metal ground plane
measured 1m*1m min. and 0.65mm thick min. and projected beyond the EUT by at least
0.1m on all sides.
For Signal Ports and Telecommunication Ports:
The EFT interference signal through a coupling clamp device couples to the signal
and control lines of the EUT with burst noise for 1min.
For Input DC and AC Power Ports:
The EUT is connected to the power mains through a coupling device that directly
couples the EFT interference signal.
Each of the Line and Neutral conductors is impressed with burst noise for 1 min.
The length of power cord between the coupling device and the EUT shall be 1m.
5.5. Test Specification
According to EN 61000-4-4:1995+ A1: 2001
5.6. Uncertainty
The measurement uncertainty is defined as ± 8.80 %
Report No:085319R-HPCEP01V01
Page: 29 of 49
5.7. Test Result
Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link
Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Date of Test 2008/04/03 Environment 23C, 52%RH
Test Condition EFT/B
Inject
Line Polarity
Voltage
kV
Inject
Time
(Second)
Inject
Method
Complied
to
Criteria Result
L-N ± 1kV 60 Direct A PASS
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV of Line .
No false alarms or other malfunctions were observed during or after the test.
Report No:085319R-HPCEP01V01
Page: 30 of 49
5.8. Test Photo
Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Description: EFT/B Test Setup
Report No:085319R-HPCEP01V01
Page: 31 of 49
6. Surge
6.1. Test Equipment List
Instrument Manufacturer Type No. Serial No Cal. Date
Schaffner NSG 2050
System Mainframe Schaffner N/A N/A Dec., 2007
Surge test Noiseken LSS-15AX N/A Nov., 2007
Note: All equipments upon which need to be calibrated are with calibration period of 1 year.
6.2. Test Setup
Report No:085319R-HPCEP01V01
Page: 32 of 49
6.3. Limits
Item Environmental Phenomena
Units Test Specification Performance Criteria
Performance Criteria
Signal Ports and Telecommunication Ports (See 1) and 2))
Surges Line to Ground
Tr/Ts uS KV
1.2/50 (8/20) 1 TT,TR B
Input DC Power Ports
Surges Line to Ground
Tr/Ts uS KV
1.2/50 (8/20) 0.5 TT,TR B
AC Input and AC Output Power Ports
Surges Line to Line Line to Ground
Tr/Ts uS KV KV
1.2/50 (8/20) 1 2
TT,TR B
Notes:
1) Applicable only to ports which according to the manufacturer’s may directly to outdoor
cables.
2) Where normal functioning cannot be achieved because of the impact of the CDN on the
EUT, no test shall be required.
6.4. Test Procedure
The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane
measured 1m*1m min. and 0.65mm thick min. and projected beyond the EUT by at least 0.1m
on all sides. The length of power cord between the coupling device and the EUT shall be 2m
or less.
For Input and Output AC Power or DC Input and DC Output Power Ports:
The EUT is connected to the power mains through a coupling device that directly couples
the surge interference signal.
The surge noise shall be applied synchronized to the voltage phase at 00, 900, 1800, 2700
and the peak value of the ac. voltage wave. (Positive and negative)
Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with
interval of 1 min.
6.5. Test Specification
According to EN 61000-4-5:1995+ A1: 2001
6.6. Uncertainty
The measurement uncertainty is defined as ± 7.93 %
Report No:085319R-HPCEP01V01
Page: 33 of 49
6.7. Test Result
Product Industrial GSM/GPRS Modem Test Mode Mode 1: GSM 900 GPRS Link
Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition Surge
Inject
Line Polarity Angle
Voltage
kV
Time
Interval
(Second)
Inject
Method
Complied
to
Criteria Result
L-N ± 0 1kV 60 Direct A PASS
L-N ± 90 1kV 60 Direct A PASS
L-N ± 180 1kV 60 Direct A PASS
L-N ± 270 1kV 60 Direct A PASS
Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line .
No false alarms or other malfunctions were observed during or after the test.
Report No:085319R-HPCEP01V01
Page: 34 of 49
6.8. Test Photo
Test Mode : Mode 1: GSM 900 GPRS Link Mode 2: GSM 900 GPRS Idle Mode 3: DCS 1800 GPRS Link Mode 4: DCS 1800 GPRS Idle
Description: SURGE Test Setup
Report No:085319R-HPCEP01V01
Page: 35 of 49
7. Conducted Susceptibility (CS)
7.1. Test Equipment List
Item Equipment Manufacturer Model No./ Serial No. Last Cal. 1 Signal Generator R & S SYM02/ 825454/ 029 Sep., 2007
2 Universal Radio Communication Tester
R & S CMU200/ 104846 Apr., 2008
3 Audio Analyzer R & S UPL / 100137 Apr., 2008 4 Mouth Simulator B & K Type 4227/ 2439692 Aug., 2007
5 Dual Microphone Supply
B & K Type 5935/ 2426784 Aug., 2007
6
Probe Microphone B & K Type 4182/ 2278070 Aug., 2007
7 1/2 Microphone Preamplifier
B & K Type 2669/ 2426609 Aug., 2007
8 Power Amplifier A & R 100W10000M7/ A285000010
N/A
9 Power Amplifier A & R 150A220/ 23067 N/A 10 Power Meter R & S NRVD/ 100219 Apr., 2008 11 Directional Coupler A & R DC2600/ 1007850-501 N/A 12 CDN Lüthi CDN L-801 M2/M3 / 2043 Jun., 2008 13 No.5 EMC Fully Chamber N/A
Note: All equipments upon which need to be calibrated are with calibration period of 1 year.
7.2. Test Setup
Report No:085319R-HPCEP01V01
Page: 36 of 49
7.3. Limits
Item Environmental
Phenomena Units Test
Specification
Enclosure Port
Radio-Frequency Electromagnetic Field Amplitude Modulated
MHz V (rms, Un-modulated) % AM (1kHz)
0.15-80 3 80
Limits Performance Criteria
Uplink speech level<reference level-35dB Downlink speech level<reference level-35dBRXQUAL≦3
CT,CR
7.4. Test Procedure
The EUT is placed on a table that is 0.8 meter height, and a ground reference plane is
placed on table and use a 10cm insulation between the EUT and ground reference plane.
For Signal Ports and Telecommunication Ports
The disturbance signal through a coupling and decoupling networks (CDN) or EM-clamp
device couples the signal to the telecommunication lines of the EUT.
For Input DC and AC Power Ports
The EUT is connected to the power mains through a coupling and decoupling networks for
power supply lines. And CDN-M2 for two wires or CDN-M3 for three wires was used directly
to couple the disturbances signal into EUT.
All the scanning conditions are as follows:
Condition of Test Remarks
1. Field Strength 130dBuV(3V) Level 2
2. Radiated Signal AM 80% Modulated with 1kHz
3. Scanning Frequency 0.15MHz – 80MHz
4. Dwell Time 3 Seconds
5. Frequency step size f : 1%
6. The rate of Swept of Frequency 1.5 x 10-3 decades/s
.
Report No:085319R-HPCEP01V01
Page: 37 of 49
7.5. Test Specification
According to EN 61000-4-6: 1996+ A1: 2001
7.6. Uncertainty
The measurement uncertainty is defined as ± 6.17 %
Report No:085319R-HPCEP01V01
Page: 38 of 49
7.7. Test Result
Product Industrial GSM/GPRS Modem
Test Mode Mode 1: GSM 900 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition CS Test Range 0.15-80MHz
Report No:085319R-HPCEP01V01
Page: 39 of 49
Product Industrial GSM/GPRS Modem
Test Mode Mode 3: DCS 1800 GPRS Link
Date of Test 2008/05/27 Environment 23C, 52%RH
Test Condition CS Test Range 0.15-80MHz
Report No:085319R-HPCEP01V01
Page: 40 of 49
7.8. Test Photo
Test Mode : Mode 1: GSM 900 GPRS Link Mode 3: DCS 1800 GPRS Link
Description: Conducted Susceptibility Test Setup
Report No:085319R-HPCEP01V01
Page: 41 of 49
Attachement
EUT Photograph
(1) EUT Photo
(2) EUT Photo
Report No:085319R-HPCEP01V01
Page: 42 of 49
(3) EUT Photo
(4) EUT Photo
Report No:085319R-HPCEP01V01
Page: 43 of 49
(5) EUT Photo
(6) EUT Photo
Report No:085319R-HPCEP01V01
Page: 44 of 49
(7) EUT Photo
(8) EUT Photo
Report No:085319R-HPCEP01V01
Page: 45 of 49
(9) EUT Photo
(10) EUT Photo
Report No:085319R-HPCEP01V01
Page: 46 of 49
(11) EUT Photo
(12) EUT Photo
Report No:085319R-HPCEP01V01
Page: 47 of 49
(13) EUT Photo
(14) EUT Photo
Report No:085319R-HPCEP01V01
Page: 48 of 49
(15) EUT Photo
(16) EUT Photo
Report No:085319R-HPCEP01V01
Page: 49 of 49
Reference: Laboratory of License