Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S 1 1 TEST REPORT UL 1993 Self-Ballasted Lamps and Lamp Adapters UL 8802 Outline of Investigation for Germicidal Systems Report Number.................................. : 20ITC1214308S Tested by:...................................... Amanda Chen Reviewed by:..................................: Apple Huang Approved by:.................................: John Liu Date of issue........................................: Dec. 22, 2020 Total number of pages....................... : 33 Pages Testing Laboratory............................ : Shenzhen iTC Product Testing Co., Ltd. Address........................................... : Room 204 , No.10, Phase 1, Zone 3, Xinxing Industrial Park,Xinhe Community, Fuhai Street, Bao'an District, Shenzhen,Guangdong.China Applicant’s name................................ : Aopu Lighting (Jinyun) Co. Ltd Address................................................ : 1# Daqiaojie Shuhong Town Jinyun County Lishui, Zhejiang Province 321400 Test specification: Standard..............................................: UL 1993:2018Self-Ballasted Lamps and Lamp AdaptersUL 8802:2020 Outline of Investigation for Germicidal Systems Test procedure................................... : UL test report Non-standard test method................: N/A Test Report Form No...................... : UL 1993_1A Master TRF......................................... : Dated 2020-07-23 General disclaimer: The test results presented in this report relate only to the object tested. Test Item description ............................... AC Duct UV Light Trade Mark ............................................... COOSPIDER Manufacturer............................................. Aopu Lighting (Jinyun) Co. Ltd Manufacturer Address............................ 1# Daqiaojie Shuhong Town Jinyun County Lishui, Zhejiang Province 321400 Model/Type reference ............................. CTUV-D9,CTUV-D18, CTUV-D36 Ratings ...................................................... 110-127V~, 50/60Hz,
Transcript
Page 1: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

1

1

TEST REPORTUL 1993

Self-Ballasted Lamps and Lamp AdaptersUL 8802

Outline of Investigation for Germicidal SystemsReport Number..................................: 20ITC1214308S

Tested by:...................................... Amanda Chen

Reviewed by:..................................: Apple Huang

Approved by:.................................: John Liu

Date of issue........................................: Dec. 22, 2020

Total number of pages....................... : 33 Pages

Testing Laboratory............................: Shenzhen iTC Product Testing Co., Ltd.

Address........................................... : Room 204 , No.10, Phase 1, Zone 3, Xinxing Industrial Park,XinheCommunity, Fuhai Street, Bao'an District, Shenzhen,Guangdong.China

Applicant’s name................................ : Aopu Lighting (Jinyun) Co. Ltd

Address................................................ : 1# Daqiaojie Shuhong Town Jinyun County Lishui, Zhejiang Province321400

Test specification:

Standard..............................................: UL 1993:2018(Self-Ballasted Lamps and Lamp Adapters)UL 8802:2020 Outline of Investigation for Germicidal Systems

Test procedure................................... : UL test report

Non-standard test method................: N/A

Test Report Form No......................: UL 1993_1A

Master TRF.........................................: Dated 2020-07-23

General disclaimer:The test results presented in this report relate only to the object tested.

Test Item description ........................................ :AC Duct UV Light

Trade Mark ......................................................... :COOSPIDER

Manufacturer....................................................... :Aopu Lighting (Jinyun) Co. Ltd

Manufacturer Address...................................... :1# Daqiaojie Shuhong Town Jinyun County Lishui, Zhejiang Province321400

Model/Type reference .......................................:CTUV-D9,CTUV-D18, CTUV-D36

Ratings ................................................................ :110-127V~, 50/60Hz,

Page 2: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

2

2

List of Attachments (including a total number of pages in each attachment):-Appendix 1: Photo attachments.

Summary of testing:

Tests performed (name of test and testclause):All clauses.

Testing location:Same as above

Summary of compliance with National Differences:N/A

The product fulfils the requirements of UL 1993:2018 and UL 8802

Remark:All tests are performed on the Germicidal Light

Page 3: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

3

3

5 MECHANICAL CONSTRUCTION P

5.1 Enclosures P

5.1.1 Enclosures shall have the strength and rigidity toresist the abuses to which they are subjected,without increasing the risk of fire, electric shock,or injury to persons due to a reduction of therequired spacing for live parts or the loosening ordisplacement of live parts.

P

5.1.2 An enclosure shall be of metal or of a polymericmaterial

P

5.1.3 A metal enclosure shall comply with theminimum thickness

N/A

5.1.4 An enclosure constructed of iron or steel shall beprotected against corrosion by plating, painting,or the equivalent on both inside and outsidesurfaces.

P

5.2 Openings P

5.2.1 An enclosure shall not have openings wider than2 mm

P

5.2.2 The enclosure openings in a lamp adapter shallbe evaluated with the lamp removed.

N/A

5.2.3 hole in an enclosure through which wiresemerge

N/A

5.3 Polymeric materials P

5.3.1 polymeric material shall comply with therequirements for portable equipment

P

5.3.2 polymeric material used to enclose electricalparts shall have a Relative Thermal Index

P

5.3.3 A polymeric material used as an enclosure shallhave a flammability rating of 5-VA, 5-VB, or V-0in accordance with UL 94

P

5.3.4 A polymeric material used as an enclosure of adevice marked for wet location use shall complywith the ultraviolet light exposure test

P

5.3.5 With respect to UL 746C, the following tests arenot required to be conducted

P

5.3.6 A device shall comply with the mold-stress reliefdistortion test of Clause 8.9

P

5.3.7 A polymeric material used for direct support aselectrical insulation shall be able to withstand thehot wire ignition

P

Page 4: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

4

4

5.4 Weight and moment P

5.4.1 A device shall have weight and momentlimitations as specified in Table 5.3

P

5.4.2 A device that is constructed so that thealignment with the existing incandescentluminaire or portable luminaire requires anadjustment greater than ±20 degrees shall beprovided with adjustment of the device base withrelation to the remainder of the device.

P

5.4.3 A device intended to be used with a shade,glassware, or diffuser shall be provided with thataccessory.

P

5.4.4 A lamp adapter shall be provided with a positivemeans to retain the lamp or lamps in place inany possible mounting orientation, such as byclips, retaining springs, or the equivalent.

P

5.4.5 When the integrity of the lamp securing meansof a lamp adapter cannot be determined, thedevice lampholder shall comply with theminimum retention force values

P

6 ELECTRICAL CONSTRUCTION P

6.1 Lamp bases and lampholders P

6.1.1 A device lampholder and device base shallcomply with the requirements of CSA C22.2 No.43 and UL 496

P

6.1.2 A screwshell metal of a device base intended fordamp or wet locations shall be made from

N/A

6.1..3 a device lampholder of a fluorescent lampadapter shall be tested with the lamp or lampsthat the device is intended to accommodate

N/A

6.1.4 A device which does not comply with Clause6.1.3 shall comply with the lamp starting andoperating measurements of Clause 8.3.

P

6.2 Current-carrying parts P

6.2.1 A wire shall have insulation rated for the voltage,temperature, and conditions of intended use.

P

6.2.2 Where loosening or breaking of electricalconnections involves a risk of fire or electricshock, the connections shall be soldered,welded, or otherwise securely connected

P

6.2.3 A wire is considered to be mechanically securewhen one or more of the following

P

6.2.4 Iron or steel, plain or plated, shall not be used for P

Page 5: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

5

5

current-carrying parts unless it is a wire integralto the lamp light source or parts used for thecontainment of electromagnetic or electrostaticfields

6.2.5 With respect to Clause 6.2.4, stainless-steel isacceptable to be used for current carrying parts

P

6.2.6 An uninsulated live part shall be permanentlymounted and secured in accordance with Clause6.2.3 to reduce the likelihood of turning orshifting position if such motion can result in areduction of spacings below minimumacceptable values

P

6.2.7 An accessible wire between a lamp connectorfor a circular lamp

P

6.3 Printed circuit boards P

6.3.1 printed circuit wiring is considered part of theballast, and shall comply with UL 935

P

6.4 Ballasts and LED drivers P

6.4.1 a ballast for fluorescent lamps shall comply withthe requirements of UL 935 and have Class Pthermal protection

N/A

6.4.2 A ballast not previously investigated asdescribed in Clause 6.4.1 shall be evaluated inthe device.

N/A

6.4.3 A ballast for fluorescent lamps shall be subjectedto the following tests

N/A

6.4.4 Regarding the fault condition testing specified inClause 6.4.3 (b), the following fault conditionsshall be introduced, one at a time – notnecessarily in the order indicated

P

6.4.5 A fusing resistor used for thermal protection shallcomply with UL 1412 or the requirements ofCAN/CSA-C22.2 No. 60065-03 (R2008) or therequirements of NMX-J-578-ANCE

P

6.4.6 A printed wiring board trace intended to open asa result of an abnormal condition is notpermitted.

P

6.4.7 a magnetic coil operating above Class 105temperature limits shall have an insulationsystem complying with UL 1446

P

6.4.8 Drivers for light-emitting diodes (LEDs) vary incomplexity from simple to complex circuits

P

6.5 Power capacitors P

6.5.1 a power capacitor shall comply with the P

Page 6: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

6

6

applicable requirements specified in UL 935.

6.6 Spacing of electrical parts P

6.6.1 For other than on a printed wiring board, thespacing of electrical parts through air (clearance)and over the surface of insulating material(creepage distance) shall be at least asdescribed in Clauses 6.6.2 and 6.6.3

P

6.6.2 Alternate spacing requirements may be appliedas specified in Clauses 6.6.5 to 6.6.7

P

6.6.3 A spacing described in Clause 6.6.1 shall not beless than the values specified in Table 6.1

P

6.6.4 For a printed wiring board, the spacing ofelectrical parts for the ballast shall comply withthe requirements of UL 935 or CSA C22.2 No.74 as applicable

P

6.6.5 as an alternative to the spacing requirementsspecified in Clauses 6.6.2 to 6.6.4, the clearanceand the creepage distance between conductiveparts that are rigidly held in place and reliablyspaced in production may be evaluated forcompliance with UL 840

P

6.6.6 when applying the requirements specified in UL840 to determine clearances, the device may beconsidered as operating on a supply circuithaving an over-voltage of Category II

P

6.6.7 when applying the requirements specified in UL840 to determine environmental pollution, thedevice may be evaluated with differentenvironmental pollution degrees

P

6.7 Accessibility of live parts P

6.7.1 Accessibility of hazardous live parts shall bedetermined when the articulated probe of Clause9.6 is inserted through any opening withoutcontacting any hazardous live parts.

P

6.7.2 The articulated probe of Clause 9.6 shall notcontact any bare live parts of the lampholdercontacts of a fluorescent adapter with the lampremoved.

P

6.7.3 A non-current-carrying metal part, such as thehead of a screw or rivet, is not considered to beexposed to contact if it is recessed to clear thesurface by at least 5 mm (0.197 in) in a hole notmore than 7 mm (0.275 in) in diameter.

P

6.8 Light source – fluorescent lamps N/A

6.8.1 Fluorescent discharge lamps shall be tested to N/A

Page 7: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

7

7

simulate end-of-lamp-life conditions

6.9 Light source – light emitting diodes (LED) P

6.9.1 Light-emitting diodes (LEDs) emitting coherentlight shall not be used

P

6.9.2 LEDs used in the subject screw-base lampsshall not be user replaceable

P

6.9.3 LEDs used in the subject screw-base lampsshall not be provided with shunt devices thatwould handle the current in the event the LEDshad open-circuited

P

6.10 Light source – non-discharge lamps N/A

6.10.1 Adapters with a lamp containment barrier andemploying replaceable tungsten halogen lampsshall be marked with a lamp caution inaccordance with Table 10.1, Items 8 and 17

N/A

6.10.2 Adapters employing replaceable tungstenhalogen lamps where the lamp has an integralcontainment barrier shall be marked with amaximum lamp caution in accordance with Table10.1, Items 8 and 16.

P

6.10.3 Adapters complying with Clause 6.10.1 orClause 6.10.2 may be marked indicating thelamp is suitable for use in an open type luminairein accordance with Table 10.1, Item 18.

P

7 ENVIRONMENTAL LOCATIONS P

7.1 Dry locations P

7.1.1 A device intended for use only in dry locationsshall be marked in accordance with Table 10.1,Item 9.

P

7.1.2 The device or packaging of a device intended foruse in dry locations shall not be marked in anymanner that could imply or depict that it issuitable for a damp or wet use location.

P

7.2 Damp locations N/A

7.2.1 A device intended for use in damp locations andmarked in accordance with Table 10.1

N/A

7.3 Wet locations N/A

7.3.1 A device intended for use in wet locations andmarked in accordance with Table 10.1

N/A

8 TESTS P

8.1 General P

Page 8: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

8

8

8.1.1 Compliance with this standard is checked byconducting the tests specified and appropriatefor the product

P

8.1.2 Tests described in this section useinstrumentation, apparatus, and environmentalconditions that are described in Clause 9.

P

8.1.3 Manufacturing and production tests shall becarried out in accordance with Annex D

P

8.1.4 The tests shall be conducted on samples asspecified in Table 8.1

P

8.1.5 All tests shall be conducted with the deviceconnected to a supply circuit of rated frequency.

P

8.1.6 A device rated 50 – 60 Hz need only be tested at60 Hz unless testing at 50 Hz represents a moresevere condition

N/A

8.1.7 Prior to taking the measurements required byClauses 8.2 to 8.4, it will in some cases benecessary to take preliminary measurementsusing an oscilloscope to determine the nature ofthe available currents. An AC/DC meter shall beused for measuring DC.

P

8.1.8 A device with discharge lamp or lamps shall beaged for 100 hours while connected to a supplyof nominal rated voltage, and then all lamp typesbeing tested shall be connected to a regulatedsource of supply at rated voltage and operatedfor 30 minutes prior to conducting the inputmeasurements test of Clause 8.2.

P

8.1.9 Where more than one fluorescent lamp has acommon base, for example a G-23 base for 5-,7-, and 9-W twin tube lamps, and a G-24q-1base for 10- and 13-W quad lamps, tests onlamp adapters shall be conducted with the lampsthat will result in the most severe condition.

P

8.2 Input measurements P

8.2.1 With the ballast energized at the input voltageand frequency in accordance with Clauses 8.1.5,8.1.6, and 8.1.8, the input current shall not bemore than 110 percent of the marked rating

P

8.2.2 For devices intended for use on a dimmer circuit,the input current measured during the test ofClause 8.12.2.1 shall not be more than 110percent of the marked rating.

P

8.2.3 For a device with a marked power factor rating,the power factor (PF) shall be calculated usingthe following formula

P

Page 9: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

9

9

8.3 Lamp starting and operating measurements P

8.3.1 amp adapters with the lamp adapter energizedat the input voltage and frequency as specified inClauses 8.1.5 and 8.1.6

P

8.4 Leakage-current test P

A device with an exposed non-current-carryingmetal part shall comply with the leakage currentrequirements in UL 935

P

8.5 Temperature test P

8.5.1 A device shall be tested as described in Clauses8.5.2 to 8.5.13.

P

8.5.2 The maximum temperatures shall not exceedthose specified in Table 8.2 when corrected to aroom ambient temperature of 25 ±5 °C

P

8.5.4 The normal temperature test shall be conductedwith the device energized in accordance withClause 8.1.5.

P

8.5.5 A device that is not marked in accordance withTable 10.1, Item 13, shall comply with thedimmer tests of Clause 8.12.

P

8.5.6 A device that is not designed for use in a totallyenclosed luminaire, and that is marked inaccordance with Table 10.1, Item 15, shall besubjected to the normal temperature test with thedevice mounted base-up in the test fixture asshown in Figure 9.1 and with the bottom open.

P

8.5.7 A lamp adapter that can accommodate variouslamp types and wattages shall be tested with thelamp that will result in the most severetemperatures

P

8.5.8 The test shall be continued until constanttemperatures are obtained.

P

8.5.9 Thermocouples shall comply with Clause 9.3. P

8.5.10 A thermocouple junction and the adjacentthermocouple lead wire shall be securely held inthermal contact with the surface of the materialof which the temperature is being measured

P

8.5.11 The temperature of a winding shall be measuredby a thermocouple or by the rise of resistancemethod in accordance with Clause 8.5.12

P

8.5.12 The temperature of a winding shall be calculated P

8.5.13 As it is generally necessary to de-energize thewinding before measuring R, the value of R atthe end of the test may be determined by taking

P

Page 10: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

10

10

several resistance measurements at shortintervals, beginning as quickly as possible afterthe instant of shutdown

8.6 Dielectric voltage-withstand test P

8.6.1 A device with accessible non-current-carryingmetal parts that could be energized from withinshall withstand for 1 minute, without breakdown,the application of a test potential of twice therated voltage + 1000 V between all live parts andall accessible non-current-carrying metal parts.

P

8.6.2 A device with accessible nonmetallic parts andopenings in the enclosure shall withstand for 1minute, without breakdown, the application of atest potential of 2500 V between live parts andmetal foil in contact with accessible nonmetallicparts

P

8.6.3 The dielectric voltage-withstand test shall beconducted using test equipment having a 500VA or larger transformer, the output voltage ofwhich can be varied. The applied potential shallbe increased from zero until the required testvalue is reached, and shall be held at that valuefor 1 minute.

P

8.6.4 The sensitivity of the test equipment shall besuch that when a 120,000 ohms minimumcalibrating resistor is connected across theoutput, the equipment indicates acceptableperformance for any output voltage less than thespecified test voltage, and indicatesunacceptable performance for any outputvoltage equal to or greater than the specified testvoltage.

P

8.7 Harmonic distortion test P

8.7.1 A device rated for a harmonic factor (HF) or totalharmonic distortion (THD) of the supply currentshall be tested as described in Clause 8.7.2 and8.7.3

P

8.7.2 The supply for the test shall be generated by anelectronic power supply having a voltagedistortion of less 0.5 percent

P

8.7.3 The magnitude of the various harmonics of thesupply frequency shall be recorded to the thirty-third (33) harmonic

P

8.8 Drop impact test P

8.8.1 A device with a polymeric enclosure shall besubjected to the tests described in Clauses 8.8.2and 8.8.3.

P

Page 11: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

11

11

8.8.2 A device shall be subjected to the impact test P

8.8.3 A device having accessible non-current-carryingmetal parts that could be energized from withinshall subsequently be subjected to the dielectricvoltage-withstand test of Clause 8.6.

P

8.8.4 Accessibility criteria are not applied to brokendischarge tubes.

N/A

8.9 Mold-stress relief conditioning P

8.9.1 A completely assembled device having apolymeric enclosure shall be placed in acirculating air oven and maintained at atemperature 10 °C higher than maximumtemperature taken during the normaltemperature test of Clause 8.5 when tested in arecessed luminaire, or not less than 70 °C for aperiod of 7 hours.

P

8.9.2 For a family or grouping of enclosures, such asdifferent sizes for a range of lamp wattages,representative samples of the largest and thesmallest enclosures shall be tested

P

8.9.3 After conditioning, there shall be no softening ofthe material as determined by handlingimmediately after the conditioning, nor shallthere be shrinkage, warpage, or other distortionas judged after cooling to room temperature

P

8.10 Deflection test P

8.10.1 The enclosure of a device shall be capable ofwithstanding a force of 89 N (20.0 lbf) appliedusing a 12 mm (0.472 in) diameter rod with ahemispherical end.

P

8.10.2 This test is applicable only for devices havingenclosures consisting of two molded pieces thatsnap together

P

8.10.3 The force shall be gradually increased from zerountil the specified value is reached and thenmaintained for a period of one minute. The force,when applied along a joint of snap-together partsor to any part of the enclosure, shall not result ina shock hazard or damage that can create a firehazard.

P

8.11 Strain relief test for lamp connectors P

8.11.1 The lamp lead wires that exit the enclosure of acircular fluorescent device shall be subjected toa perpendicular force of 22 N (5 lbs) applied toeach lead wire for 1 min

P

8.11.2 The lamp leads exiting from the enclosure shall P

Page 12: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

12

12

have no movement of any lead greater than 1.6mm (1/16 in) after the force of Clause 8.11.1 isapplied.

8.12 Tests of dimmer circuits P

8.12.1 General P

8.12.1.1 A device that is intended to operate on astandard dimmer, shall be subjected to thenormal operation test specified in Clause 8.12.2.

P

8.12.1.2 A device that is not intended to be dimmable,shall be subjected to the abnormal temperaturetest of Clause 8.12.3. These devices shall bemarked in accordance with Table 10.1, item 13.

P

8.12.1.3 A dimmable device that is not intended tooperate on a standard dimmer (e.g.: wirelesscontrol) shall be subjected to the abnormaltemperature test of Clause 8.12.3 with itsintegral dimming control set for full brightness.

P

8.12.2 Normal operation test P

8.12.2.1 Devices described in Clause 8.12.1.1 shallcomply with the temperature test of Clause 8.5when operated with power supply sources ofClauses 8.12.4 and 8.12.5.

P

8.12.3 Abnormal test P

8.12.3.1 Devices described in Clauses 8.12.1.2 or8.12.1.3 shall be energized with the sources ofsupply specified in Clauses 8.12.4 and 8.12.5, ina room ambient of 25 °C in the base downposition.

P

8.12.3.2 When operated as specified in Clause 8.12.3.1for 7½ hours

P

8.12.4 Half-wave rectified supply P

8.12.4.1 A source of supply as specified in Clauses 8.1.5and 8.1.6 shall be operated with a single,appropriately rated semiconductor diode inseries with the ungrounded conductor of thesupply.

P

8.12.5 Adjustable dimmer supply N/A

8.12.5.1 A source of supply as specified in Clause 8.1.5shall be operated with an adjustable dimmerelectrically wired in series

N/A

8.13 Humidity conditioning P

8.13.1 A device intended for use in damp or wetlocations (see Clauses 7.2 and 7.3) shall beexposed for 48 hours to moist air having arelative humidity of 93 ±5 % at a temperature of

P

Page 13: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

13

13

25 ±2 °C

8.14 Water spray test P

8.14.1 A device intended for use in wet locations (seeClause 7.3) shall be subjected to the testdescribed in Clause 8.14.2

P

8.14.2 A device shall be tested by applying a waterspray as described in Clause 9.7 for 1 hour

P

8.15 Cold impact test P

8.15.1 A device with a polymeric enclosure and markedfor use in wet locations shall comply with thecold impact test (-35 °C)

P

8.15.2 Three samples shall be cooled to a temperatureof -35 ±2 °C and maintained at this temperaturefor 3 hours. While the unit is cold, the specimensshall be subject to the drop test described indrop test in Clause 8.8.

P

8.16 Lamp fault conditions test P

8.16.1 A self-ballasted lamp or adapter that employs anelectronic ballast shall accept the following faultconditions specified, introduced one at a time,without increasing the risk of fire or shock:

P

8.16.2 The fault conditions specified in Clause 8.16.1shall be simulated as follows:

P

8.16.3 A self-ballasted lamp or adapter shall be placedon a knot-free pine board covered with a doublelayer of cheesecloth. A double layer ofcheesecloth shall be draped over the unit.

P

8.16.4 The self-ballasted lamp or adapter shall beenergized from a power supply of rated voltageand frequency.

P

8.16.5 The results of the test comply with this standard P

8.17 End-of-lamp-life tests for fluorescent lampadapters

P

8.17.1 General P

8.17.1.1 Any one of the following three tests may be usedto qualify a lamp adapter

P

8.17.1.2 The manufacturer shall declare which one of thethree tests will be used to test a given adapter,based on the design of that particular adaptercircuit.

P

8.17.1.3 Lamps used in the adapter test circuits shall benew lamps seasoned for 100 h

P

8.17.2 Asymmetric pulse test P

Page 14: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

14

14

8.17.2.1 Refer to the schematic diagram in Figure 8.3. P

8.17.2.2 The following values of maximum cathode powerPmax apply

P

8.17.2.3 If only one connection per electrode is availableat the ballast and/or lamp, T1 shall be removed,and then the ballast shall be connected to J2and the lamp to J4

P

8.17.2.4 The following components are used in theasymmetric pulse test circuit

P

8.17.2.5 he specification for the transformer (T1) listed inClause 8.17.2.4

P

8.17.3 Asymmetric power test P

8.17.3.1 Refer to the schematic diagram in Figure 8.4 P

8.17.3.2 The test sequence shall be as follows P

8.17.3.3 The following components are used in theasymmetric power test

P

8.17.4 Open filament test P

8.17.4.1 Test selection P

8.17.4.1.1 The adapter shall have adequate protection toprevent lamp base overheating at the end of thelamp life cycle under open filament conditions.Compliance is checked by either test procedureA or B as determined by the value of Imaxbelow.

P

8.17.4.1.3 If these current values are exceeded, testprocedure B shall be applied; otherwise testprocedure A shall be applied.

P

8.17.4.2 Measurements to be carried out prior to testprocedure A

P

8.17.4.2.1 Connect the circuit according to Figure 8.5. P

8.17.4.2.2 Determine the rms currents ILL(1), ILH(1),ILL(2), and ILH(2) at the adapter outputterminals, by using a current probe, and markthe terminals respectively

P

8.17.4.3 Test procedure A P

8.17.4.3.1 The test sequence shall be as follows a-k P

8.17.4.3.2 The following components are used in the openfilament test circuit for test procedure A,electrode (1)

P

8.17.4.4 Test procedure B N/A

8.17.4.4.1 Connect the lamp as shown in Figures 8.5 and8.6 with the measurement arrangement

N/A

Page 15: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

15

15

according to Figure 8.7

8.17.4.4.2 The test sequence shall be as follows a-h N/A

8.17.4.4.3 The following components are used in the openfilament test circuit for test procedure B, thedetection of lamp current

N/A

8.18 End-of-life test for integral, self-ballastedfluorescent lamps – one filament emission-mix-free test

N/A

8.18.1 A self-ballasted lamp shall be tested asdescribed in Clauses 8.18.2 to 8.18.5.

N/A

8.18.2 Six samples shall be used for the test. Three ofthe samples shall have no emission-mix on onelamp filament and the other three samples shallhave no emission-mix on the other lampfilament.

N/A

8.18.3 During the test, the device shall be energized atthe input voltage and frequency. The deviceshall be oriented base up unless the packagingclearly indicates the bulb is not to be operated inthis orientation. The samples may be operated inan open environment.

N/A

8.18.4 The samples shall be observed during the testfor any evidence of smoke, fire, or cracking ofthe bulb wall.

N/A

8.18.5 The results of the test comply with this standard N/A

8.19 15-VA available power measurement test P

8.19.1 When evaluated per Clauses 8.19.2 – 8.19.7,the power available to a circuit is not consideredto be a risk of fire if the maximum poweravailable to the circuit is less than 15 VA underany loading condition, including short circuit,measured after one minute of operation.

P

8.19.2 The point in the circuit under evaluation shall beconnected to the measurement circuit as shownin Figure 8.8 The external adjustable loadresistor shall be initially set for its maximumresistance

P

8.19.3 If the supply to circuit under evaluation consistsof other than a single resistor, the test describedin Clause 8.19.2 shall be repeated under anysingle component fault conditions within thesupply circuit likely to result in greater outputpower availability. The fault condition shall firstbe applied, and then the variable resistance loadshall be adjusted as needed.

P

8.19.4 With respect to Clause 8.19.3, components for N/A

Page 16: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

16

16

which the reliability against failure has beendeemed acceptable by a separate evaluationshall not be faulted. Examples of suchcomponents include optical isolators evaluatedto CSA Component Acceptance Service No. 5 orUL 1577; and capacitors evaluated to CAN/CSA-E60384-14 or UL 60384-14.

8.19.5 If the test is disrupted by the operation of asuitable protective component

P

8.19.6 If the test is disrupted by the failure of othercircuit components (e.g.: capacitor,semiconductor, coil winding) then that test shallbe repeated two additional times, with newsamples, under the same test condition. Testdisruption by opening of the same, or a different,component during these repeated tests isacceptable.

P

8.19.7 If there is any indication of componentoverheating during any of the tests described inClauses 8.19.2 – 8.19.6 (e.g.: odor, smoke,discoloration, glowing, cracking, melting, orchanges in circuit current through the fault), thetest condition shall be repeated as part of eitherthe Fault-Condition Test

N/A

9 TEST APPARATUS P

9.1 General P

9.1.1 Clause 9.1 summarizes test equipment andenvironmental conditions needed for thelaboratory facility where testing would beconducted.

P

9.1.2 Unless otherwise specified, the tests shall becarried out at an ambient temperature of 20 °Cto 30 °C with a relative humidity between 30 and70%. Atmospheric pressure is not specified.

P

9.1.3 Test equipment shall be in a schedule of initialcalibration and periodic re-calibration

P

9.1.4 Test equipment shall have a method of specificidentification, such as serial number or a uniquelaboratory numbering system, so that theequipment used for the test may be noted in theresults of the test.

P

9.2 Instrumentation P

9.2.1 The voltage in other than the supply circuit shallbe measured using a voltmeter or voltmeter-multiplier combination having a resistance of notless than 10,000 Ω/V.

P

Page 17: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

17

17

9.2.2 For determining values of voltage, a true rmsindicating meter having a frequency response atleast three times the frequency involved andhaving an adequate crest factor (ratio of peak torms) shall be used.

P

9.2.3 If it is necessary to determine peak-voltagevalue, an oscilloscope with a high-impedance(10 MΩ minimum) input probe shall be used.

P

9.2.4 For thermocouple measurements, either athermocouple potentiometer or an electronicinstrument shall be used. An electronicinstrument shall have an accuracy at least asgood as the thermocouples described in Clause9.3.

P

9.3 Thermocouples P

9.3.1 Thermocouples shall consist of wires not largerthan 24 AWG (0.21 mm2) and not smaller than30 AWG (0.05 mm2). It is standard practice toemploy thermocouples consisting of 30 AWGiron-constantan (Type J) wires and apotentiometer-type or electronic instrument; andsuch equipment shall be used whenever refereetemperature measurements by thermocouplesare necessary

P

9.3.2 Thermocouples consisting of chromel-alumel(Type K) or copper-constantan (Type T) wiresmay be used if it is determined that high-frequency ballast operation results in eddycurrent heating of iron-constantanthermocouples.

P

9.4 Plywood test box material P

9.4.1 The plywood used for constructing temperaturetest boxes shall be 12-mm (1/2-in trade size)thick with at least one side that has all voidsfilled and sanded.

P

9.5 Temperature test box P

9.5.1 Test apparatus for a device with an input ratingless than 50 W

P

9.5.2 Test apparatus for a device with an input ratinggreater than 50 W for an enclosed lampcompartment

P

9.5.2.1 The device shall be tested in the enclosed testfixture described below for the normaltemperature test. The sides and top of the testfixture shall be constructed of 12.7 mm (1/2 intrade size) thick minimum grade C-D or betterplywood. The bottom shall be closed off with a

P

Page 18: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

18

18

2.5 mm (0.1 in) thick piece of window glass ofappropriate size.

9.5.2.2 The test fixture shall have a square cross-section. The dimensions of the sides of thesquare shall be specified by the self-ballastedlamp manufacturer and marked on the self-ballasted lamp.

P

9.5.2.3 A lampholder shall be mounted to the inside topof the center of the box and 0.82 mm2 (18 AWG)insulated conductors of suitable temperature andvoltage rating supply power shall be connectedto it

P

9.5.3 Normal temperature test apparatus for a devicewith an input rating greater than 50 W for anopen luminaire

P

9.5.3.1 The temperature test apparatus shown in Figure9.2 shall be constructed as a-g

P

9.6 Articulated probe P

9.6.1 See Figure 9.3 for articulated test probespecifications

P

9.7 Water spray apparatus N/A

9.7.1 The water spray test apparatus shall consist ofthree spray heads constructed in accordancewith the details specified in Figure 9.4 andmounted in a water supply pipe rack asillustrated in Figure 9.5.

N/A

9.8 Cheesecloth P

9.8.1 The cheesecloth shall be bleached cheesecloth,914 mm (36 in) wide, running 26 to 28 m2/kg (14to 15 yd2/lb) and having what is known in tradeas a count 32 by 28.

P

10 DEVICE MARKINGS P

10.1 General P

10.1.1 A device shall be legibly marked using one ormore of the following methods a-k

P

10.1.2 A pictogram in accordance with Annex F may beused as a substitute for the corresponding text ofTable 10.1 and shall be the subject of specialinspection.

P

10.1.3 A marking shall be of the minimum size (S____)and in the location (L____) shown in the“Format” column of Table 10.1 and as defined inTables 10.2 and 10.3.

P

Page 19: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

19

19

10.1.4 “Verbatim” in the “Text” column of Table 10.1indicates that the marking shall consist of onlythe exact words shown or a marking includingthese words and conveying the original intent.Alternative wording for other markings in thetable may be used subject to evaluation.

P

10.1.5 All markings shall have lettering in which P

10.1.6 Pressure-sensitive labels of the permanent type(Type P) that are secured by adhesive shall bein accordance with CSA C22.2 No. 0.15 or UL969. The adhesive of the pressure-sensitivelabels shall be suitable for the applicationsurface, temperature, and environment.

P

10.2 Identifications and ratings P

10.2.1 A device shall be marked with the following a-d P

10.2.2 A device shall be marked with an electrical inputrating in volts, hertz, wattage, and current inaccordance with Table 10.1, Item 5. Hertz canbe omitted if volts is expressed as “VAC” and thedevice has been evaluated for 60 Hertz, or ifvolts is expressed as “VDC.”

P

10.2.3 A lamp adapter shall be marked with a wattagerating as specified in Table 10.1

N/A

10.2.4 A device with a power factor rating greater than0.90 may be marked in accordance with Table10.1,

N/A

10.2.5 Unless the device is tested with the lens asdescribed in Clause 8.5.6, the device shall bemarked in accordance with Table 10.1, Item 15.

P

10.2.6 In the United States, self-ballasted fluorescentlamps shall be marked as described in Table10.1, Item(s) 19, 20 or both. The smallest unitpackaging, point-of-sale package, carton, or“stuffer sheet” packed with a lamp shall containthe marking described in Table 10.1, Item(s) 29,30 or both.

P

10.2.7 When a marking in Table 10.1 has acorresponding symbol in Annex F andinstructions are included on the packagingexplaining the pictogram’s meaning, the symbolmay be used in place of the corresponding textin Table 10.1.

P

10.3 Marking requirements in Mexico N/A

10.4 Instructions P

10.4.1 A device weighing over 200 g (0.44 lbs) shall beprovided with instructions in accordance with

P

Page 20: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 1993

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

20

20

Table 10.1, Items 21 and 22.

10.4.2 device, typically not intended for use in free-standing portable luminaires, such as a PAR- orR-shaped bulb, is not required to comply withClause 10.4.1

P

10.4.3 A device employing a lamp, such as a circularlamp, that extends outside of the harp of aportable luminaire shall be provided with aninstruction in accordance with Table 10.1, Item23, or shall be marked as required by Clause10.4.1.

P

10.4.4 The instructions shall include the statement inTable 10.1, Item 24.

P

10.4.5 The instructions for a device marked inaccordance with Table 10.1, Item 14, shallinclude the following or equivalent statement:″Only use the control provided with or specifiedby these instructions to control this lamp. Thislamp will not operate properly when connectedto a standard (incandescent) dimmer or dimmingcontrol.″

P

Page 21: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

21

21

6 CONSTRUCTIONGeneral

P

6.1 The emitters used as part of a germicidal systemshall comply with all construction and testrequirements in CSA C22.2 No. 250.0 or UL1598 applicable to the installation method andenvironmental location for which it is marked andintended. In addition, emitters that employ LEDUV or light sources shall additionally comply withCSA C22.2 No. 250.13 or UL 8750. Equipmentthat uses low-pressure mercury vapor dischargelamps shall comply with the requirementsapplicable to fluorescent luminaires.

P

6.2 Emitters shall be designed to be permanentlymounted in a fixed location, such that it cannotbe unmounted or relocated without the use oftools.

P

6.3 Emitters not intended to be adjusted by the end-user shall be designed such that it is notpossible to re-orient or refocus the emitterwithout the use of tools.

N/A

6.4 All system components shall either be providedby the system manufacturer, or clearly specifiedin the installation instructions as a componentthat the installer is required to source separately.See 12.3(b).

P

7 Photobiological Assessment P

7.1 Emitters shall be subjected to a photobiologicalassessment across the UV wavelength rangefrom 200 nm through 400 nm in accordance withthe requirements in CAN/CSA-C22.2 No. 62471(in Canada) or IEC 62471 (in the United States).This assessment shall be used to determine therisk group of the equipment.

P

7.2 This assessment shall be conducted using ameasurement distance from the radiation sourceof 200 mm (8 in) in the direction likely to producethe most severe test result.

P

7.3 The equipment shall be adjusted and operatedto produce the most severe test result permittedby its construction and installation instructions.

P

Page 22: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

22

22

7.4 Safeguards and other controls intended to permitintermittent equipment operation (e. g. motionsensors, timers, etc.) shall be bypassed ordisabled so that the equipment will operatecontinuously duringthe assessment.

P

7.5 The results of this assessment shall be used toselect the appropriate product and packagingmarkings in 12.8.

P

8 Ozone Assessment P

8.1 Equipment that emits ultraviolet radiation atwavelengths less than 250 nm shall comply withthe Ozone Test in CSA-C22.2 No. 187 or UL867. The Ozone Test is not required if theeffective irradiance from wavelengths less than250 nm is no more than 1% of that generated inthe 250-400 nm bands.

P

9 Safeguards P

9.1 Germicidal systems shall incorporate at least twoindependent electrical or mechanical safeguards(i.e.: primary and secondary) to reduce theoverexposure risk if the system is inadvertentlyor intentionally operating while the treated spaceis occupied. This may be accomplished with anycombination of site and equipment safeguards.Safeguards shall be installed near or within thetreated space to reduce the likelihood ofoccupancy immediately before or during emitteroperation. Examples of such safeguards include:

P

9.2 Safeguards shall operate independently of oneanother. The failure of any single safeguard shallnot disable or degrade the remainingsafeguards, unless the fault also results in a safeshutdown. Compliance is determined by theSafeguard Assessment, Clause 10.

P

Page 23: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

23

23

9.3 When a safeguard is mounted less than 2.1 m (7ft) above the floor, any adjustments, intentionalor otherwise, that can be accomplished by handor by using ordinary tools (e.g.: blocking orpainting over a sensor, disconnecting a wire orconnector, etc.) shall either:a) Not affect the operation of the remainingsafeguards;b) Prevent system engagement and operationuntil repairs can be made; orc) Result in a safe shutdown.

P

9.4 Safeguards are considered integral componentsof a germicidal system and shall be selected andused in line with their ratings, markings andintended use. Safeguards shall comply withapplicable safety standards as components ofthe system, in accordance with Clause 2.

N/A

9.5 System components that comply with one of thefollowing standards are considered to complywith 9.4 when they are used in line with theirratings, markings and intended use:

P

10 Safeguard Assessment P

10.1 The germicidal system, with all necessaryelectrical and mechanical components in place,shall be evaluated to assess each site orequipment safeguard intended to comply with9.2. This assessment maybe performed as an engineering review (e. g.:fault tree analysis), a series of actual faults on arepresentative system, or any combinationthereof.

P

10.2 The assessment is considered acceptable if anysingle safeguard failure under any scenarioresults in the emitters shutting down before aperson occupying or entering the treated spacecan be exposed to excessive UV or opticalenergy. In addition, no instance of safeguardfailure shall affect the operation of the remainingsafeguards unless the failure: a) Preventssystem engagement and operation until repairscan be made; or b) Results in a safe shutdown.

P

Page 24: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

24

24

10.3 For this assessment the germicidal system shallbe configured in the most disadvantageousconfiguration permitted by the system’sinstallation and operating instructions.Depending on thecomplexity of the system, this may requireselecting and assessing more than oneconfiguration. For eachselected configuration, the following failuremodes shall be considered:a) Electrical faults that simulate the possibleadverse operating states for the safeguard (e. g.:always open, always closed, not responsive tosignals, etc.)

P

10.4 With regard to 10.3(a), internal electrical faultsare not required on controls that comply with oneof the following:a) Type 2 protective controls or Type 2 operatingcontrols that comply with CAN/CSA E60730-1 /UL 60730-1, and the Part 2 applicable to thecomponent;b) Safety controls that comply with CSA-C22.2No. 205 / UL 916; o

P

10.5 Each safeguard failure shall be simulated undereach of the following operating scenarios, inturn:a) Scenario #1 – The instructed operatorengages the germicidal system, a singlesafeguard isfaulted, then someone attempts to access thetreated space.b) Scenario #2 – A single safeguard is faulted,the instructed operator engages the germicidalsystem, then a person attempts to access thetreated space.

P

Page 25: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

25

25

MARKINGSAdvisory Note: In Canada, there are two officiallanguages. Therefore, it is necessary to haveCAUTION, WARNING, and DANGERinstructions and markings in both English andFrench. Annex B lists acceptable Frenchtranslations of the CAUTION, WARNING, andDANGER instructions and markings specified inthis outline of investigation. When a product isnot intended for use in Canada, instructions andmarkings may be provided in English only

P

11 Safety Instructions P

11.1 The safety instructions shall be a permanent partof the manual but separated in format andpreceding all other instructions (such asinstallation, operation, and maintenanceinstructions).

P

11.2 The safety instructions shall include instructionsor illustrations to identify important safetyfeatures, in addition to the important safeguardslisted in 11.5.

P

11.3 The height of lettering in the text and illustrationsof the safety instructions shall be as follows:a) The phrases "IMPORTANT SAFEGUARDS","READ AND FOLLOW ALL SAFETYINSTRUCTIONS", and "SAVE THESEINSTRUCTIONS" shall be in letters not less than4.8 mm (3/16 inch) in height.b) Other upper-case letters shall not be less than2.1 mm (1/12 inch) in height.c) Lower-case letters shall not be less than 1.6mm (1/16 inch) in height.

P

11.4 The items may be numbered. The phrases"READ AND FOLLOW ALL SAFETYINSTRUCTIONS"and "SAVE THESE INSTRUCTIONS" shall befirst and last, respectively, in a list of items.Other important safeguard items consideredappropriate by the manufacturer are to beinserted in between these phrases.

P

Page 26: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

26

26

11.5 For all equipment, the safety instructions shallinclude the following safeguards verbatim or inequally definitive terminology. If a specificsafeguard does not apply to a particular type ofequipment, the safeguard may be modified ordeleted as appropriate. Text in brackets “[ ]” shallbe selected based on theequipment’s light source:

P

12 Additional Markings and Instructions P

12.1 The instruction manual shall include instructionsfor system installation, operation, maintenance,and PPE for qualified service personnel asrecommended by the manufacturer. Theinstructions shall state that installation andservicing should be performed by qualifiedservice personnel.

P

12.2 The instruction manual for equipment withsunlamp products, lasers or high-intensitymercury vapor discharge lamps shall contain themanufacturer’s declaration of conformity to theapplicable provisions of applicable US Federalrequirements, including 21 CFR, Chapter 1,Subchapter J, Radiological Health.

P

12.3 The installation and operating instructions shallinclude at least the following items:a) A complete parts list of all required systemcomponents, which may also includephotographs orline drawings of all system components andcontrols;b) All required components that are not providedby the system manufacturer shall be specified bymanufacturer and catalog number. Alternatively,they can be specified parametrically (e. g.: byelectrical and mechanical parameters) only if theparametric description was taken into accountduring the safeguard assessment of thecomponent;

P

12.4 All emitters shall be marked in accordance withTable 12.1, items 1 – 3.

P

Page 27: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

27

27

12.5 The compartment or area that contains a userreplaceable light source shall be marked inaccordance with Table 12.1, items 4 and 5. Themarking shall be located on the external surfaceof the equipment where readily visible during anyapproach to the compartment or area. This itemmay optionallyinclude item 7.

P

12.6 The instruction manual shall include detailedinformation for properly locating the componentsof a system in a given space. This informationshall include, as applicable, drawings depictingexamples of correct installations, as well asexamples of unacceptable installations that maypose a risk of UV overexposure (e.g. installationat inappropriate heights, locations ororientations, open sightlines between theradiation source and exposed upper floors, stairsor walkways, etc.).

P

12.7 For equipment that use user-replaceableemission sources (e.g. UV generating lamps) thelamp replacement marking in Table 12.1, item 6shall be provided. If there is more than onepermitted lamp, this marking may be provided asa table or list.

N/A

12.8 With regard to 7.5, all emitters shall be providedwith all the applicable markings in 12.9 and12.10 unless their emitters are classified as:a) Risk Group 1 or 0 for both Retinal Blue Lightspectral bands; andb) Risk Group 0 for the remaining spectralbands.

P

12.9 Emitters shall be provided with all risk groupproduct and packaging markings consistent withthe labeling and other information provisions inIEC/TR 62471-2, Tables 1 and 2, as follows:a) Product markings – Format S24L1, layout per12.10, provided on the product;b) Packaging markings – Format S24L4, layoutper 12.10, provided on the product's outerpackaging where visible to the user prior toopening, and on any instruction sheet packedwith the product.

P

Page 28: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

UL 8802

Clause Requirement + Test Result - Remark Verdict

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

28

28

12.10 The product and packaging markings in 12.9shall be presented in bold block print within ablack bordered two-section box on a yellowbackground, as follows:a) The risk group classification in the upper box.For products that exceed Risk Group 0 in morethan one spectral band, the most severe riskgroup classification shall be used; andb) The required labeling, information andguidance text in the lower box. When more thanone hazard is noted, the text shall be printed inorder of descending severity, each separated bya blank line.

P

13 Warning Labels P

13.1 The manufacturer shall provide labels that areintended to be affixed adjacent to points ofaccess to the treated area. They shall be markedwith the word “WARNING”, and the following orequivalent statement, “RISK OF PERSONALINJURY. AN ULTRAVIOLET (UV) GERMICIDALSYSTEM ISINSTALLED IN THIS AREA. TO PREVENT UVOVEREXPOSURE, DO NOT ENTER THISROOM WHEN THE SYSTEM IS INOPERATION.”

P

13.2 The markings described in 13.1 shall be inletters not less than 6.4 mm (1/4 inch) high andprinted on a contrasting background.

P

Page 29: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

29

29

MECHANICAL STRENGTH OF SCREWSHELLAND SCREW BASE (CONT'D):

DIELECTRIC VOLTAGE-WITHSTAND TEST

PWB TestPoints

MeasuredPotential(Vp)

DC TestPotential

(2Vp+1000)PWB TestPoints

MeasuredPotential(Vp)

DC TestPotential

(2Vp+1000)-- 1 400 1800 -- 11 -- ---- 2 400 1800 -- 12 -- ---- 3 400 1800 -- 13 -- --

INPUT MEASUREMENTS

Model NumberElectrical Measurements

(V) (Hz) (A) (W)

CTUV-D9 110 60 0.101 11.2

CTUV-D9 127 60 0.821 10.5

LEAKAGE CURRENT TEST

Model Number(Sample No.)

Test Sequence and Input Polarity (MIU)

Step b(OFF, Cold)

Step c(ON, Cold)

Step d(ON, Warm)

Step e(OFF, Warm)

A B A B A B A B

CTUV-D9 0.02 0.01 0.02 0.02 0.02 0.02 0.02 0.01

Model NumberSampleNumber

Acceptable Results (Y/N)?

Pull Torsion

CTUV-D9 S01 Y Y

Page 30: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

30

30

TEMPERATURE TEST

Thermocouple locationsTEST Voltage

-- Limit(ºC)110V 127V

Ambient 26.5 26.3 -- -- --Diffuser, inside, near UV 48.1 47.1 -- -- 115

Diffuser, inside, on top of UV 64.6 62.6 -- -- 115Plug cord 53.6 54.3 -- -- 85

Input Leads, near L 52.1 54.2 -- -- 125L1 coil 53.6 56.7 -- -- 130L3 coil 58.4 58.9 -- -- 130T1 coil 63.2 64.7 -- -- 120C3 body 66.8 69.6 -- -- 125C4 body 65.2 66.5 -- -- 125

LED LAMP AND DRIVER ABNORMAL CONDITION TESTS(ABNORMAL TESTS)

ModelNumber

DescriptionOf Fault1 Test Observations

CTUV-D9 D1 short Fuse (F1) Opened, No visible defects

on the enclosure.

C2 short Fuse (F1) Opened, No visible defectson the enclosure.

C1 short Unit shut down, Recoverable, Novisible defects on the enclosure.

C5 short Unit shut down, Recoverable, Novisible defects on the enclosure.

D6 short Unit shut down, Recoverable, Novisible defects on the enclosure.

Q1 (D-S) short Fuse (F1) Opened, No visible defectson the enclosure.

T1 Pin(3-1)short

Unit shut down, Recoverable, Novisible defects on the enclosure.

T1 Pin(4-5)short

Recoverable, No visible defects on theenclosure.

Page 31: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

31

31

-Appendix 1: Photo document.

Photo 1

Photo 2

Page 32: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

32

32

Photo 3

Photo 4

Page 33: TESTREPORT UL1993 Self-BallastedLampsandLampAdapters … · 2021. 1. 21. · UL1993 Clause Requirement+Test Result-Remark Verdict Tel:(86)-0755-33138690 Fax:(86)-0755-23071003 ShenzheniTCProductTestingCo.,Ltd.

Tel: (86)-0755-33138690 Fax: (86)-0755-23071003 www.itclab.cn

Shenzhen iTC Product Testing Co., Ltd. Report No.: 20ITC1214308S

33

33

Photo 5

-------------------End of report--------------