2
ARCTIC CHILLER GROUP Arctic Boost Option Manufacturer of Premium Efficiency Cooling Solutions The Arctic Chiller Group PRODUCT RELEASE • Available for both air-cooled and water-cooled units • Previously unseen compressor efficiencies • Allows compressor to run down to a 1.1 pressure ratio • Suitable for higher leaving chilled water temperatures as in data center or chilled beam applications • Refrigerant pump ensures proper compressor motor cooling during low lift operation • Eliminates the need for a water-side economizer and all of the associated space, control points, and unstable loop temperatures associated with one • No switchover procedure is required • Zero maintenance required on the system • Can replace the integral free-cooling coil optional on air-cooled chillers Allows wider range of application including higher chilled water temps, lower condensing temps, and better continuous unloading. 120 100 80 60 40 SDT ˚F SST ˚F 30 35 40 45 50 55 60 65 70 Low Lift comp Map Low Lift zone Standard map 1.1 Pr 1.5 Pr Water-cooled unit Air-cooled unit with high leaving water temperature Low lift option extends the compressor operating envelope 2019 FINALIST
Transcript

A R C T I C C H I L L E R G R O U P

Arctic Boost Option

Manufacturer of Premium Efficiency Cooling SolutionsThe Arctic Chiller Group

PRODUCT RELEASE

• Available for both air-cooled and water-cooled units

• Previouslyunseencompressorefficiencies

• Allows compressor to run down to a 1.1 pressure ratio

• Suitable for higher leaving chilled water temperatures as in data center or chilled beam applications

• Refrigerant pump ensures proper compressor motor cooling during low lift operation

• Eliminates the need for a water-side economizer and all of the associated space, control points, and unstable loop temperatures associated with one

• No switchover procedure is required

• Zero maintenance required on the system

• Can replace the integral free-cooling coil optional on air-cooled chillers

Allows wider range of application including higher chilled water temps, lower condensing temps, and better continuous unloading.

120

100

80

60

40

SDT ˚F

SST ˚F 30 35 40 45 50 55 60 65 70

Low Lift comp Map

Low Lift zone

Standard map

1.1 Pr

1.5 Pr

Water-cooled unit Air-cooled unit with high leaving water temperature

Low lift option extends the compressor operating envelope

2019

F INAL IST

United States Canada71 Industrial Park Road 2100 Steeles Avenue EastNewberry, SC 29108 Brampton, ON L6T 1A7(803) 321-1891 (905) 789-9988Toll Free: (800) 849-7778 Toll Free: (800) 339-8982Fax: (803) 321-1898 Fax: (905) 789-9989

Visit our website at www.arcticchillergroup.com

PR-100-1905

The Arctic Chiller Group

NowPossible:Improvedultra-highefficienciesshownatlowloadpointsandvariousfallingcondensingtemperatures

Refrigerant pump on the motor-cooling line ensures the proper operation of the compressor as it runs in the low lift area of the operating envelope.

Typical water side economizerArctic Boost liquid pump

versus


Recommended