Journal of Physics D: Applied Physics PAPER The assessment of cold atmospheric plasma treatment of DNA in synthetic models of tissue fluid, tissue and cells To cite this article: Endre J Szili et al 2017 J. Phys. D: Appl. Phys. 50 274001 View the article online for updates and enhancements. Related content Modelling the helium plasma jet delivery of reactive species into a 3D cancer tumour Endre J Szili, Jun-Seok Oh, Hideo Fukuhara et al. - How to assess the plasma delivery of RONS into tissue fluid and tissue Jun-Seok Oh, Endre J Szili, Nishtha Gaur et al. - Studying the cytolytic activity of gas plasma with self-signalling phospholipid vesicles dispersed within a gelatin matrix Serena E Marshall, A Toby A Jenkins, Sameer A Al-Bataineh et al. - Recent citations UV–vis spectroscopy study of plasma- activated water: Dependence of the chemical composition on plasma exposure time and treatment distance Jun-Seok Oh et al - Absolute ozone densities in a radio- frequency driven atmospheric pressure plasma using two-beam UV-LED absorption spectroscopy and numerical simulations A Wijaikhum et al - This content was downloaded from IP address 128.32.198.188 on 22/02/2018 at 22:37
Transcript
Page 1: The assessment of cold atmospheric plasma treatment of DNA ...

Journal of Physics D: Applied Physics

PAPER

The assessment of cold atmospheric plasmatreatment of DNA in synthetic models of tissuefluid, tissue and cellsTo cite this article: Endre J Szili et al 2017 J. Phys. D: Appl. Phys. 50 274001

 

View the article online for updates and enhancements.

Related contentModelling the helium plasma jet delivery ofreactive species into a 3D cancer tumourEndre J Szili, Jun-Seok Oh, HideoFukuhara et al.

-

How to assess the plasma delivery ofRONS into tissue fluid and tissueJun-Seok Oh, Endre J Szili, Nishtha Gauret al.

-

Studying the cytolytic activity of gasplasma with self-signalling phospholipidvesicles dispersed within a gelatin matrixSerena E Marshall, A Toby A Jenkins,Sameer A Al-Bataineh et al.

-

Recent citationsUV–vis spectroscopy study of plasma-activated water: Dependence of thechemical composition on plasma exposuretime and treatment distanceJun-Seok Oh et al

-

Absolute ozone densities in a radio-frequency driven atmospheric pressureplasma using two-beam UV-LEDabsorption spectroscopy and numericalsimulationsA Wijaikhum et al

-

This content was downloaded from IP address 128.32.198.188 on 22/02/2018 at 22:37

Page 2: The assessment of cold atmospheric plasma treatment of DNA ...

1 © 2017 IOP Publishing Ltd Printed in the UK

Journal of Physics D: Applied Physics

The assessment of cold atmospheric plasma treatment of DNA in synthetic models of tissue fluid, tissue and cells

Endre J Szili1,9, Nishtha Gaur1,2,9, Sung-Ha Hong1, Hirofumi Kurita3, Jun-Seok Oh4, Masafumi Ito4, Akira Mizuno3, Akimitsu Hatta5,6, Allison J Cowin1, David B Graves7, and Robert D Short1,8

1 Future Industries Institute, University of South Australia, Adelaide, SA 5095, Australia2 Wound Management Innovation Cooperative Research Centre, Australia3 Department of Environmental and Life Sciences, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan4 Department of Electrical and Electronic Engineering, Meijo University, Nagoya 468-8502, Japan5 Department of Electronic and Photonic Systems Engineering, Kochi University of Technology, Kami, Kochi 782-8502, Japan6 Center for Nanotechnology, Research Institute of Kochi University of Technology, Kami, Kochi 782-8502, Japan7 Department of Chemical and Biomolecular Engineering, University of California, Berkeley, CA 94720, United States of America8 Materials Science Institute and Department of Chemistry, The University of Lancaster, City of Lancaster LA1 4YW, United Kingdom

E-mail: [email protected]

Received 20 March 2017, revised 5 May 2017Accepted for publication 25 May 2017Published 15 June 2017

AbstractThere is a growing literature database that demonstrates the therapeutic potential of cold atmospheric plasma (herein referred to as plasma). Given the breadth of proposed applications (e.g. from teeth whitening to cancer therapy) and vast gamut of plasma devices being researched, it is timely to consider plasma interactions with specific components of the cell in more detail. Plasma can produce highly reactive oxygen and nitrogen species (RONS) such as the hydroxyl radical (OH•), peroxynitrite (ONOO−) and superoxide ( −O2 ) that would readily modify essential biomolecules such as DNA. These modifications could in principle drive a wide range of biological processes. Against this possibility, the reported therapeutic action of plasmas are not underpinned by a particularly deep knowledge of the potential plasma-tissue, -cell or -biomolecule interactions.

In this study, we aim to partly address this issue by developing simple models to study plasma interactions with DNA, in the form of DNA-strand breaks. This is carried out using synthetic models of tissue fluid, tissue and cells. We argue that this approach makes experimentation simpler, more cost-effective and faster than compared to working with real biological materials and cells. Herein, a helium plasma jet source was utilised for these experiments. We show that the plasma jet readily induced DNA-strand breaks in the tissue fluid model and in the cell model, surprisingly without any significant poration or rupture of the phospholipid membrane. In the plasma jet treatment of the tissue model, DNA-strand breaks were detected in the tissue mass after pro-longed treatment (on the time-scale of minutes) with no DNA-strand breaks being detected in the tissue fluid model underneath the tissue model. These data are discussed in the context of the therapeutic potential of plasma.

E J Szili et al

Printed in the UK

274001

JPAPBE

© 2017 IOP Publishing Ltd

50

J. Phys. D: Appl. Phys.

JPD

10.1088/1361-6463/aa7501

Paper

27

Journal of Physics D: Applied Physics

IOP

9 Szili and Gaur are equal co-first authors.

2017

1361-6463

1361-6463/17/274001+15$33.00

https://doi.org/10.1088/1361-6463/aa7501J. Phys. D: Appl. Phys. 50 (2017) 274001 (15pp)

Page 3: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

2

Keywords: plasma jet, DNA, molecular beacon, tissue model, synthetic cell model, phospholipid vesicles, plasma medicine

S Supplementary material for this article is available online

(Some figures may appear in colour only in the online journal)

1. Introduction

There is a high degree of optimism that cold atmospheric plasma technologies will develop to significantly aid in the treatment of diseases, e.g. chronic wounds and cancers. It has been shown through in vitro cell studies and in vivo animal experiments that cold atmospheric plasma, herein referred to as plasma, might accelerate wound healing by stimulation of cell growth and migration [1–11], and also decontaminate infected wounds through targeted destruction of bacterial cells [12–22]. Similar results have been obtained in clinical studies where the efficacy of plasma in wound decontami-nation and healing has been demonstrated [23–26]. Apart from wounds, there is a rapidly growing interest in the use of plasma in cancer therapy. It has been demonstrated through in vitro cell studies that plasma can destroy cancer cells through various molecular pathways [27–32]; and it has been shown in vivo that plasma can be used to shrink tumours in rodents [33–35]. A clinical study has shown that plasma treatment may benefit cancer patients through pain relief, reduction in microbial load, partial tumour remission and improved wound healing [36]. To date there have been no reports of signifi-cant adverse effects from the clinical use of plasma; although plasma treatment has been reported to induce mild skin irrita-tion, swelling, inflammation and superficial burns [23, 33, 36, 37]. And no significant adverse effects from plasma have been seen in patients following longer term clinical observations 12 months post plasma treatment [38].

The mechanism of plasma intervention in biology and medicine is thought to be mainly governed by reactive oxygen species (ROS) and reactive nitrogen species (RNS), or col-lectively RONS [39–41]. Experimentally, using models of tissue fluid, tissue and cells, it has been shown that plasma- generated RONS are not only delivered into tissue fluid but can also potentially be delivered deep within a tissue mass and across a phospholipid membrane into cells [7, 42–53]; comp-uter simulations corroborate these experimental observations [54–61]. In the physiological environment, RONS regulate key biochemical pathways, inducing chemical and physical changes in cells [39, 62]. Where plasma-derived RONS intervene in bio-logical processes is now a topic of great interest [39].

In cancer therapy, it has been argued that plasma-generated RONS detrimentally affect cancer cells whilst not damaging healthy cells due to differences in membrane composition and the molecular machinery between cancer and healthy cells. Arguments have been advanced that include: (1) the reduced cholesterol content in cancer cell membranes make these membrane more susceptible to pore formation, which ena-bles a higher ingress of RONS that increases oxidative stress

[55]; (2) the elevated intrinsic oxidative stress in cancer cells increases their vulnerability to oxidative damage [29]; and (3) the higher proliferation rates in cancer cells makes new DNA formed during the S-phase of the cell cycle more sus-ceptible to oxidative damage [35]. In wound decontamination, the greater susceptibility of bacterial cells to plasma induced oxidative damage could arise from the increased surface area-to-volume ratio of these prokaryotic cells when compared to eukaryotic cells [46]; an increase in surface area:volume would lead to higher concentrations of RONS delivered into prokaryotes with a concomitant increase in oxidative stress.

The cell stimulatory effect of plasma has also been explained by the plasma delivery of RONS to tissue fluid, tissue and cells [6, 7]. Generally, if the dose or rate of delivery (flux) of RONS is kept low enough it is argued that RONS enhance cell proliferation. But, if the dose/flux of RONS con-tinues to increase, it will almost certainly cause significant cell damage, eventually leading to cell death. In skin cells it has been shown that plasma can have beneficial or deleterious effects depending on the dose and flux of RONS [6, 7]. The stimulatory effect of plasma at low RONS doses and detri-mental effect at high RONS doses have been described in terms of the principle of ‘hormesis’ [7, 63, 64]; a term com-monly used for medical drugs where low doses are beneficial but high doses are not [65].

In the clinical use of plasma, the safety level (dose) for each different component of plasma such as RONS, neutral atoms and molecules, electrons and UV radiation, needs consideration in order to prevent potential (longer term) damaging effects. The safety requirements for plasma devices intended for clin-ical use have been discussed in a review by Heinlin et al [66]. Consideration has included electrical, UV, and reactive spe-cies components of plasma and the transmission of electrical current through skin. Plasma devices for medical use, such as the MicroPlaSter, have been reported to meet these require-ments [66]. In addition, the inherent electric fields of plasma devices are expected to be relatively high and in the order of kV cm−1 for some plasma devices [67]. Electric fields may play an important role in the plasma delivery of RONS through tissue [50, 51] and cell membrane [54] barriers. Consequently, electric field also requires careful consideration in the clinical application of plasma because of its potential to disrupt the integrity of tissue and cell membrane barriers.

However, the therapeutic action of plasma still relies on poorly understood cellular and tissue modifications, although some insights have emerged in recent years [41, 68, 69]. The central role for RONS now appears well established, but the mechanisms by which plasma-generated RONS affect cellular processes is still a topic of intense study and uncertainty. For

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 4: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

3

example, in many cases, the biological effects of plasma-gen-erated RONS are likely to act through intermediate chemical species. This conclusion is drawn from an elementary consid-eration of the short lifetimes and diffusion distances of highly-reactive RONS when compared to the likely time and distance required for these RONS to reach cells in situ within tissue fluid and tissue, or even in in vitro cell culture media.

Although the safety requirements for the clinical use of plasma are being addressed in detail, a more holistic under-standing of the nature of the possible damaging effects of plasma exposure is arguably still required in order to progress ‘plasma medicine’ laboratory research into the clinic. There is no question that the biological effects of plasma exposure are related to the intensity (power level) of the plasma and time of plasma exposure. The precise nature of the ‘biological plasma dose’ is not well understood. But if the plasma treatment is too intense or too long, cells and tissue will be damaged or killed. For this reason, plasma devices approved for clinical use are operated within well-defined and carefully tested operational protocols. For example, the kINPen MED argon plasma jet source has been shown to be non-mutagenic when tested using in vitro ISO protocols [70] and in vivo tests with chicken embryos [71]. Bekeschus et al concluded that use of the kINPen MED for wound healing ‘does not pose any health risks in humans with regard to UV exposure, thermal damage, tissue toxicity, or mutagenicity’ [72].

Nevertheless, confidence in knowing the parameters of safe operation does not provide any insight into the possible mechanisms by which plasma exposure could cause signifi-cant cellular damage, including DNA damage. And, whilst no significant short or longer term adverse side-effects from plasma have been reported to date, it is important to continu-ally review the safety of plasma. In the 2012 international ‘Plasma Roadmap’, Kroesen used an analogy with plasma etching to explain the importance of addressing the safety issues of plasma in medicine [73]:

‘The semiconductor industry was using plasma etch-ing on very large scales well before a much better un-derstanding was established. All that could go wrong is a less favourable process performance. The case of plasma medicine is totally different: human beings are at stake’.

Since the breadth of applications promoted for plasma ranges from the benign, e.g. in cosmetics such as teeth whit-ening and wrinkle treatment to the destruction of tumours in cancer therapy, it is reasonable to assume that there must be a graduated scale of risk:benefit that warrants consideration. As a simple analogy (that should not be pushed too far), a small exposure to x-rays is acceptable for imaging teeth and should do no harm if performed correctly, whereas higher doses that cause significant cell damage are utilised (specifically for this reason) in targeted cancer therapy10.

Amongst the RONS that may be generated by plasmas in tissue fluid and tissue are the hydroxyl radical (OH•) and superoxide ( −O2 ) [74] and peroxynitrite (ONOO−) [75]. These RONS readily induce DNA-strand breaks [76, 77], and could explain plasma induced single- and double-strand DNA breaks in vitro [78–82]. In this study, we establish a methodology to assess plasma induced DNA-strand breaks in tissue fluid, tissue, and in cells. Rather than using real biological mat erials and cells, that would be expensive and time-consuming to work with routinely, and would significantly complicate the interpretation of any data, DNA-strand breaks are assessed in simple models of tissue fluid, tissue and cells. The main pur-pose of the tissue model we employ is to provide a barrier, similar to that encountered when plasma contacts any human tissue. The models utilised in these experiments are:

• DNA: Plasma induced DNA-strand breaks in the tissue fluid, tissue or cell models are assessed with a molecular beacon (MB) as previously described [80]. The MB is an oligonucleotide comprising a single-strand loop and double-strand stem structure. At the end of the stem is a 5′-fluorescent moiety and a 3′-quenching moiety. Single- or double-strand DNA breaks in the MB can result in separation of the quencher and fluorophore leading to switch-on of fluorescence. See figures 1(a)–(d).

• Tissue fluid: A 4-(2-hydroxyethyl)-1-piperazineethane-sulfonic acid buffer (herein referred to as HEPES), which mainly comprises water, is used as a substitute for tissue fluid. HEPES is commonly used in cell cultures because of its excellent buffering capacity. See figure 1(a).

• Tissue: Gelatin is used as a substitute for the tissue barrier. Gelatin consists of collagen, one of the most abundant extracellular proteins, and provides a barrier to topically administered hydrogen peroxide (H2O2) solution (and by inference other RONS) [50]. See figures 1(b) and (c).

• Cells: Phospholipid vesicles are used to mimic the bar-rier of the phospholipid membrane of real cells. Reporter molecules can be packaged into the vesicles to analyse different processes such as RONS ingress and membrane permeability [46, 48, 49]. See figure 1(d).

The data are discussed in the context of obtaining a better understanding of plasma interactions with biological systems and the potential safety risks that could arise in the context of DNA-strand breaks. In addition, a simple method is devel-oped to limit DNA-strand breaks whilst enabling the plasma delivery of longer-lived RONS. Specifically, we consider the delivery H2O2. This method involves placing a hydrogel dressing in-between the plasma jet and the target liquid: the hydrogel acts as a ‘RONS filter’ enabling the rapid delivery of H2O2 (and other longer-lived RONS) whilst preventing the delivery of shorter-lived RONS to the target.

2. Experimental

2.1. Plasma jet

The plasma source utilised was a ‘plasma jet’ configuration. The plasma jet comprised a 150 mm long glass tube, tapered from an

10 We note that the application of x-rays cannot exert a beneficial biological response because x-rays ionise cells. However, treatment with plasmas can be used to stimulate cells (e.g. proliferation or migration) because plasmas do not ionise cells.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 5: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

4

inner diameter of 4 mm to 650 µm at the nozzle. A 15 mm long external ring copper electrode, wound onto the glass tube at a dis-tance of 40 mm from the end of capillary, served as the powered electrode. The plasma jet was used in a single electrode configura-tion with no designated grounded (second) electrode. The helium (He) gas (BOC, high purity grade) flow through the glass tube was controlled at 0.05 and 0.5 standard litres per minute (slpm) with a digital mass flow controller (Apex, 0–2 slpm flow range). A sinusoidal voltage of 10 kVp–p (peak-to-peak) at 30 kHz was applied to the external electrode with a PVM500 power supply (Information Unlimited). A 10 mm thick polytetrafluoroethylene (PTFE) housing was used to shield the high voltage electrode for safety. The treatment distance was 1 mm between the nozzle of the plasma jet assembly and the top of 96-well plate, or tissue model or hydrogel dressing. A photograph of the plasma jet device is shown in figure 2(a) and a diagrammatical representation of the plasma jet device with the experimental parameters in figure 2(b).

2.2. Reagents

The details of the reagents used in this study are shown in table 1. All reagents were used without further purification.

2.3. HEPES tissue fluid model

The following reagents were dissolved in 100 ml of water:

• HEPES—238.3 mg • NaCl—624 mg

• NaOH—22.4 mg • EDTA—29.22 mg

The solution was adjusted to pH 7.4 with drop-wise addi-tion of 10 mM NaOH. The solution was filtered through a 0.2 µm syringe filter.

2.4. Tris-base buffer

Concentrated 1 M Tris-base buffer was prepared by dissolving 12.11 g Tris-base in 80 ml water. The pH was adjusted to 7.6 with concentrated HCl (6.2 M). The final volume was adjusted to 100 ml with water. The concentrated Tris-base buffer was diluted to 10 mM in water for preparation of the MB stock solution.

2.5. Assessment of DNA-strand breaks with the MB

The MB was supplied at a concentration of 37 nmole in each bottle. The MB was dissolved in 372 µl of 10 mM Tris-base buffer (pH 7.6) to obtain an end concentration of 100 µM (ini-tial stock concentration). Two (working) concentrations were utilised for the experiments: 0.5 µM for treatment of the tissue fluid and tissue models, and 50 µM diluted in HEPES for vesicle encapsulation. The MB, at the different working con-centrations, was prepared for the experiments by denaturing the MB at 95 °C for 3 min, and allowing the MB structure to reform slowly at ambient temperature (~25 °C) for 3 h in the dark. This procedure was carried out to ensure the correct configuration of the MB.

Figure 1. An overview of the methodology to assess DNA-strand breaks in synthetic models of tissue fluid, tissue and cells. A MB was used to assess DNA-strand breaks. A simplified structure (loop, stem and quencher (black-filled circle), fluorophore (open circle)) of the MB is shown in (a)–(d). Breakage of the MB stem from single- or double-strand DNA breaks results in separation of the quencher/fluorophore leading to a switch-on of fluorescence of the fluorophore (green-filled circle). The MB was dispersed in HEPES to assess DNA-strand breaks in the tissue fluid model (a) directly treated with a plasma jet or (b) indirectly treated through a gelatin tissue model. (c) The MB dispersed within gelatin to assess DNA-strand breaks within the tissue model itself. (d) The MB encapsulated within phospholipid vesicles to assess DNA-strand breaks within the cell models.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 6: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

5

2.6. CF vesicle poration/rupture indicator

A 50 mM concentration of the CF encapsulation buffer was prepared by adding the following to 13 ml water:

• CF—244 mg • NaCl—7.6 mg • NaOH—70.2 mg • HEPES—31 mg • EDTA—333.7 mg

2.7. Measurement of H2O2 concentration

A mixture of 2 mg ml−1 OPD powder and 4 µg ml−1 HRP was dissolved in HEPES. A volume of 200 µl of the OPD-HRP solution (herein referred to as the H2O2 indicator) was used for the direct treatment of the tissue fluid model and 400 µl for through-tissue model or through-hydrogel dressing treat-ment to ensure contact between the solution and tissue model or hydrogel dressing. Treatment with the neutral He gas jet (i.e. with no applied voltage) did not activate the H2O2 indi-cator (supporting information, figure  S1 (stacks.iop.org/JPhysD/50/274001/mmedia)); therefore, all data were nor-malised to the untreated H2O2 indicator. The H2O2 concen-tration was determined from a calibration curve constructed

from known concentrations of H2O2 solutions prepared in HEPES (supporting information, figure S2).

2.8. Phospholipid vesicle synthetic cell models

Vesicles were composed of 80% DOPC and 20% choles-terol. Although the composition of membranes for human cells is much more complex and variable between cell types and between healthy and diseased cells, phosphatidylcholines

Figure 2. The plasma jet used in this study. (a) A photograph of the plasma jet device. (b) A diagrammatical representation of the plasma jet device including a cross-section of the plasma jet assembly showing the single electrode surrounding the glass tube and the experimental treatment parameters.

Table 1. Summary of reagents used in this study.

Reagent (alphabetical order) Abbreviation Supplier Catalogue #

Ethanol Not applicable

Chem-Supply

UN1170

(Ethylenedinitrilo) tetraacetic acid disodium salt

EDTA Optigen Scientific

OS-53170

5,6-carboxyfluorescein CF Sigma-Aldrich

21877

Chloroform Not applicable

Sigma-Aldrich

288306

Cholesterol Not applicable

Sigma-Aldrich

C8667

1,2-dioleoyl-sn- glycero-3- phosphocholine

DOPC Avanti po-lar lipids

850375P

Gelatin Not applicable

Sigma-Aldrich

G1890

Horseradish peroxidase

HRP Sigma-Aldrich

P6782

Hydrochloric acid HCl RCI Labscan

RP1106

Hydrogen peroxide (30%)

H2O2 Chem-Supply

HA154

4-(2-hydroxyethyl)-1- piperazineethanesul-fonic acid

HEPES Sigma-Aldrich

H-3375

Molecular beacon MB Sigma-Aldrich

3017672631a

o-Phenylenediamine OPD Sigma-Aldrich

P9029

Sodium chloride NaCl Optigen Scientific

OS-22760

Sodium hydroxide NaOH Sigma-Aldrich

OS-367176

Tris(hydroxymethyl) aminomethane

Tris-base Sigma-Aldrich

154563

Triton X-100 Triton Sigma-Aldrich

T8797

Waterb Not applicable

Sigma-Aldrich

95283

a The MB was a custom order. The sequence is: FAM-5′-GCACTGAAGCGCCGCACGCCATGTCGACGCGCTTCAGTGC–3′-BHQ-1 (FAM is a fluorescent dye; BHQ-1 is a quencher).b High quality water was used for all experiments and for the preparation of all materials in this study. The quality of the water was important because contaminants such as traces of metals can influence the plasma generation of RONS in solution.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 7: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

6

(such as DOPC) are a major lipid found in these cell mem-branes [83], and cholesterol accounts for approximately 20% of the lipid mass in the cell membrane. A 100 µl stock solu-tion of DOPC/cholesterol was mixed with 200 µl of chloro-form, followed by drying with nitrogen gas. Then 2.5 ml of 50 µM of MB or 50 mM CF was added and the mixture was heated to 75 °C for 1 min and allowed to cool to approximately ambient temperature (~25 °C) before being extruded through two 100 nm polycarbonate membranes in a hand-held syringe extruder (Avanti Polar Lipids, model # 610000). Extrusion was repeated 7 times. The extruded solution was transferred through a Sephadex G25 column to remove non-encapsulated dye. Because the column was supplied with a reservoir of anti-bacterial solution, the first step was to flush out the anti- bacterial solution with 5 ml HEPES. This step was repeated twice and the eluate discarded. Then 2 ml of extruded vesicles and 1 ml HEPES was added. This eluate was also discarded. A further 2 ml HEPES was added and the eluate was collected. The eluate was diluted to 25% for vesicles encapsulating the MB and 50% for vesicles encapsulating CF; these concentrations were determined to be optimal from preliminary experiments.

2.9. Gelatin tissue model

A 10% (w/v) gelatin film was prepared by dissolving the gelatin powder in water at 45 °C for 60 min. A volume of 20 ml gelatin solution was poured into an 85 mm diameter (polystyrene) petri dish. The gelatin was allowed to set at 4 °C for at least 12 h before use. The gelatin was cut into approximately 20 × 20 mm2 sections and the thickness of the gelatin was 2 mm.

2.10. Hydrogel dressing

‘IntraSite Conformable’ (Smith & Nephew, catalogue # 66000324) hydrogel dressing was utilised for the experi-ments. ‘IntraSite Conformable’ comprises a hydrogel coating on a non-woven dressing. The hydrogel dressing is supplied folded in half in the packaging. To prepare the dressing, it was unfolded and the half smeared with most of the hydrogel was cut into approximately 20 × 20 mm2 sections; the other half was discarded. The dressing was pressed down onto the 96-well plate filled with 400 µl of MB solution or with the H2O2 indicator. The side of the dressing coated with most of the hydrogel contacted the solution.

2.11. Microplate reader measurements

A 100 µl volume of the test solutions was transferred to a sepa-rate 96-well plate for absorbance or fluorescence measurements. For the H2O2 indicator, the absorbance was recorded at 450 nm. Fluorescence of the MB or CF were recorded at an excitation wavelength of 485 nm and emission wavelength of 520 nm.

2.12. Data processing

Preliminary experiments revealed that the neutral He gas jet (i.e. with no applied voltage) alone does not induce DNA-strand breaks in HEPES (supporting information, figure S3).

Therefore, the raw fluorescence data were normalised to untreated MB in HEPES according to the following equation:

= −

Normalised fluorescence instensity

Fluorescence intensity of test MB suspension

Untreated MB suspension1.

(1)The same equation  was also used to normalise the fluores-cence data for the CF vesicles to measure membrane poration/rupture:

= −

Normalised fluorescence intensity

Fluorescence intensity of test CF vesicles

Untreated CF vesicles1.

(2)

All data presented in the column charts represent the mean value from triplicate samples (n = 3) and ±standard error of the mean (SEM).

2.13. Phase-contrast and fluorescence microscopy

Phase-contrast and fluorescence microscopy were performed using an inverted microscope (Nikon, TE-2000) through a 4 × objective. Fluorescence images were captured through a Nikon filter with 455–485 nm excitation and 500–545 nm emission. The same exposure time was used for all samples to enable direct comparison between images. Images were recorded with a Nikon DXM1200C digital camera and pro-cessed using NIS-Elements Basic Research v2.2 software.

3. Results

The plasma jet in operation with 0.05 or 0.5 slpm of He is shown in figure  3. With the experimental parameters employed in this study, as seen with the unaided eye, the vis-ible part of the plasma jet was confined within the tube when operated at 0.05 slpm (figure 3(a)), but extended out from the nozzle to a length of 8 mm at 0.5 slpm (figure 3(b)). At 0.05 slpm, the plasma jet did not visibly contact the HEPES target in direct treatment (figure 3(c)) but did contact at 0.5 slpm (figure 3(d)). Using optical emission spectroscopy, we con-firmed that the 0.05 slpm plasma jet did not contact HEPES but the 0.5 slpm jet did (data not shown). But in treatments through gelatin, at both flow rates the plasma jets contacted the surface of the gelatin (figures 3(d) and (e)); however, the 0.5 slpm plasma jet exhibited a greater emission intensity and formed a larger contact area with the gelatin target. We take this observation to indicate that the delivery rate of RONS will be higher with the higher flow rate plasma jet than with the lower flow rate plasma jet. In addition, we appreciate that dif-ferences in the conductivity of the target might influence the physicochemical properties of the plasma jet upon plasma jet-target interactions [84].

DNA-strand breaks were first assessed for the MB sus-pended in HEPES using the experimental set-up shown in figure 1(a). The results are shown in figure 4(a). All plasma jet treatments resulted in DNA-strand breaks. We measured H2O2 as a surrogate for the total RONS because H2O2 is the

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 8: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

7

major longer-lived RONS generated in aqueous solution for this plasma jet and the experimental configuration utilised in this study [42–44]. Longer treatment times were used with the 0.05 slpm plasma jet in an attempt to obtain similar H2O2 concentrations to those obtained with higher flow rate plasma jet treatments at shorter treatment times.

Figure 4(a) shows that the frequency of DNA-strand breaks increased with plasma jet treatment time. The shortest treat-ment times of 15 and 30 s with the higher (0.5 slpm) flow rate plasma jet resulted in the lowest frequency of DNA-strand breaks. The longest treatment time of 20 min with the lower (0.05 slpm) flow rate plasma jet resulted in most DNA-strand breaks. The concentration of H2O2 in HEPES after the plasma jet treatments is shown in figure 4(b). The concentration of H2O2 generated with the 0.05 slpm plasma jet was in the range of ~200 µM to 250 µM. Despite much shorter treatment times, the H2O2 concentration range in HEPES after 0.5 slpm plasma jet treatments was higher at >300 µM to ~1 mM. These data show a clear discrepancy in the extent of DNA-strand breaks and the total delivered concentration of RONS. The ability of H2O2 to produce DNA-strand breaks (alone) was tested over the concentration range relevant to these plasma jets; intrigu-ingly, H2O2 (added as a solution to the MB suspension) did not produce any measureable level of DNA-strand breaks (figure 4(c)). This result is mirrored in a previous simulation study by Verlackt et al who showed that the OH• directly dam-ages DNA but H2O2 does not [85]. For the plasma treatment parameters investigated in this study, we did not observe a change in the pH or temperature of HEPES directly treated with the plasma jet.

In the next experiments, DNA-strand breaks were assessed in HEPES below a gelatin target. In the employed exper-imental set-up, the plasma jet treats the surface of gelatin situ-ated on top of the 96-well, which is filled with a suspension

of MB in HEPES (figure 1(b)). Whilst it has been shown in previous studies that plasma jets readily deliver RONS to mil-limetre depths into tissue models, these targets significantly attenuate RONS delivery, particularly at the onset of plasma treatment [42–45, 47]. Therefore, in this experiment the 0.5 slpm plasma jet was employed for the much longer treat-ment time of 10 min to increase the H2O2 concentration in the HEPES below the gelatin. As shown in figure 5, no measure-able level of DNA-strands breaks was observed in HEPES. This is in contrast to the direct treatment of HEPES, where DNA-strand breaks were readily detected (figure 4(a)) and on a much shorter time-scale. However, it should be noted that the H2O2 concentration delivered by the plasma jet through the gelatin into HEPES was much lower at ~50 µM, when

Figure 3. Photograph of the He plasma jet in operation under different experimental parameters. The plasma jet is shown operated at (a), (c) and (e) 0.05 slpm or (b), (d) and (f) 0.5 slpm into the ambient air (a) and (b), or during treatment of the HEPES tissue fluid model (c) and (d), or during treatment of the gelatin tissue model (e) and (f).

Figure 4. Assessment of DNA-strand breaks in the tissue fluid model. (a) Comparative level of DNA-strand breaks after plasma jet treatments at different He flow rates and treatment times. (b) H2O2 concentrations generated in the tissue fluid model corresponding to the same plasma jet treatments in (a). (c) Effect of H2O2 on DNA-strand breaks over the concentration range relevant to the plasma jets (raw fluorescence data are shown to show comparison to 0 µM H2O2).

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 9: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

8

compared to the direct treatment of HEPES (see figures 4(b) and 5).

The above data implicate other ‘agents’ in the DNA-strand breaks beyond H2O2. And moreover, point to the requirement of direct exposure to the plasma jet for DNA-strand breaks to occur. Therefore to investigate this further, DNA-strand breaks were investigated with the MB dispersed directly and uniformly within the gelatin tissue target. The plasma jet was directly applied to the gelatin target surface as shown in figure 1(c). DNA-strand breaks were assessed by fluores-cence microscopy of the gelatin. An overlay of one typical phase-contrast and one fluorescence image of the same area are shown in figure  6 to illustrate the correlation between the treatment area on the gelatin surface and fluorescence as a result of DNA-strand breaks in the MB. DNA-strand breaks were not detected in gelatin after 60 s of treatment with the 0.5 slpm plasma jet (data not shown). But, when the treatment was increased to 10 min, DNA-strand breaks were observed at the point of impact of the plasma jet (figure 6(a)). In contrast, no DNA-strand breaks were observed after 10 min treatment with the neutral He gas jet; although the He gas jet did partially dehydrate the gelatin surface (figure 6(b)). Overall, these data show that the plasma jet can also induce DNA-strand breaks in the gelatin tissue model, but this required a treatment time-scale of minutes. Possibly longer treatment times are required to observe DNA-strand breaks in the gelatin tissue model because the shorter-lived and highly-reactive RONS (that are likely to induce sig-nificant DNA damage) are extinguished very rapidly in the gelatin matrix (compared to in HEPES). With electron spin resonance spectr oscopy, we readily observed the produc-tion of the OH• in HEPES, when directly treated with the plasma jet, but not when treated through the gelatin target (supporting information, figure  S4). Also, we do not see a further increase in the frequency of DNA-strand breaks after 1 h following plasma jet treatment (data not shown). These data indicate that there is not an appreciable amount of H2O2 converted to the OH• over the timescales investigated in this study, and that the DNA-strand breaks observed in this study are likely to be from the OH•.

In the treatment of biological cells it is important to con-sider the phospholipid cell membrane, which is a barrier that exogenous RONS must traverse in order to reach the DNA in the cell interior. Therefore, DNA-strand breaks were next examined with the MB encapsulated within phospholipid ves-icles. We appreciate that in real eukaryotic cells, RONS would also need to traverse the nuclear or mitochondrial membrane in order to reach most of the genetic material within the cell. However, for this initial study the MB was packaged into a single vesicle to assess if the RONS that pass through a single phospholipid membrane barrier can react with the DNA within the vesicle interior. The experimental set-up is shown in (figure 1(d)) and the results shown in figure 7(a). The 0.5 slpm plasma jet at the shorter treatment times induced more DNA-strand breaks within the vesicles than longer treatments with the 0.05 slpm plasma jet. (The normalised fluorescence values presented in figures 4(a) and 7(a) cannot be directly compared between the MB experiments, i.e. between the encapsulated MB and free MB (in suspension). This is because (i) different concentrations of MB were used for both experiments and (ii) it was not possible to measure the final concentration of MB encapsulated within the vesicles.)

Figure 5. Assessment of DNA-strand breaks in the tissue fluid model after plasma jet treatment through the gelatin tissue model and the corresponding H2O2 concentration generated in the tissue fluid model underneath the gelatin tissue model. The plasma jet was operated at 0.5 slpm He and the treatment time was 10 min.

Figure 6. Assessment of DNA-strand breaks within the gelatin tissue model after treatment with (a) the plasma jet or (b) with the neutral He gas jet. The figures are an overlay of the phase-contrast and fluorescence images to show the correlation between the distribution of DNA-strand breaks and the microscopic changes on the gelatin surface. The plasma or neutral gas jet was operated at 0.5 slpm He and the treatment time was 10 min. Scale bar = 250 µm.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 10: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

9

The integrity of the phospholipid membrane during plasma jet treatment was assessed employing vesicles encapsulating a self-quenched dye (CF). Packed within the vesicles there is no fluorescence and the dye only fluoresces when it is released by membrane poration or vesicle rupture—providing a clear fluorescent switch-on (figure 7(b)) [48, 49, 86]. The results are shown in figure 7(c). The measured level of CF fluores-cence was similar for all plasma jet treatments. However, the intensity of CF fluorescence following plasma jet treatments was low at only ~10% of the level obtained with a surfactant (Triton) known to induce complete vesicle lysis. Further, this 10% value is not significant (p > 0.05 from a student’s t-test), being only marginally above the level obtained with the neu-tral He gas jet treatments (also shown in figure 7(c)).

For certain medical applications, maximising plasma induced DNA-strand breaks in the target could be advanta-geous, e.g. in focused cancer therapy. However, in other applications such as the treatment of an open wound, the imperative should be to limit DNA damage. Our data show that it is difficult to inhibit DNA-strand breaks without com-promising the RONS concentration delivered by a plasma jet (see figure 4(a)). We venture that the challenge is to reduce or prevent the plasma jet from delivering highly-reactive RONS such as OH•, −O2 , and ONOO− that readily break DNA. Therefore, in the direct treatment of tissue fluid, one approach to inhibit DNA breaks would be to ‘filter’ the highly- reactive RONS from the plasma jet during treatment. This could potentially be accomplished with the use of a material

placed in-between the plasma jet and tissue that enables the (rapid) transport of gases or dissolved RONS from the plasma jet to the tissue. In this scenario, it is anticipated that highly reactive RONS (i.e. those that are more likely to induce DNA-strand breaks) would be extinguished in this material owing to their shorter lifetime and limited diffusion distances. This was tested in the final experiment where a commercial hydrogel dressing (Intrasite Conformable) was placed in-between the plasma jet and HEPES. A photograph during treatment and a diagrammatical representation of the experimental set-up are shown in figures  8(a) and (b) for HEPES treated indirectly with the plasma jet through a hydrogel dressing. Treatment was carried out with the 0.5 slpm plasma jet for 10 min. As shown in figure  8(c), the hydrogel dressing significantly attenuated the level of DNA-strand breaks in HEPES but still enabled the delivery of H2O2 at a relatively high concentra-tion of ~200 µM; a concentration comparable to HEPES directly treated with the plasma jets (compare figure 8(c) to figure  4(b)). This result adds to the evidence that the more stable, longer-lived RONS from plasma are not responsible for DNA-strand breaks.

4. Discussion

The purpose of this study was to establish a simple method-ology to assess DNA damage induced by plasma jets in the context of the use of plasma jets in biology and medicine. Key features of any such methodology are that it should be

Figure 7. Assessment of DNA-strand breaks in the phospholipid vesicle cell model. (a) Comparative level of DNA-strand breaks after plasma jet treatments at different He flow rates and treatment times. (b) Schematic representation of CF encapsulated in the phospholipid vesicles to assess membrane poration or rupture. (c) Comparative level of membrane poration or rupture of the phospholipid vesicle cell model after same plasma jet treatments as in (a); or treatment with the neutral He gas jet alone at 0.05 slpm for 20 min or 0.5 slpm for 60 s; or treatment with Triton to measure ~100% membrane rupture.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 11: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

10

reproducible, cost and time effective, not require highly-specific expertise or analytical equipment, and that the data yielded should be straightforward to interpret. As seen in the graphs, the SEM of the replicate data is relatively small indi-cating good experiment reproducibly. We attribute the good level of reproducibility to little batch-to-batch variation in the synthetic models because the fabrication processes are straightforward, and because experimentation with synthetic tissue models avoids biological variability. Generally, the costs of the reagents are low: the reagents to make the tissue fluid (HEPES), tissue model (gelatin) and cell models (phos-pholipid vesicles) are not expensive; the major cost is the MB, but the MB is used at a low concentration in 96-well formats to reduce volume requirements. The cost of the equipment is also relatively low and most of the equipment is standard to chemical and biology laboratories; such as the small hand-held extruder used for making vesicles, and the microplate reader and fluorescence microscope for measuring DNA-strand breaks. In addition, the experiments can be performed quickly, especially since DNA-strand breaks in the MB give rise to an immediate and easily interpretable switch-on of fluorescence.

The next issue is the versatility of the methodology. The results presented in this paper show that this methodology can be utilised to assess DNA-strand breaks from plasma jets in the tissue fluid model, within the tissue model, and within the cell models. The experiments can also be interfaced with micro-plates for higher through-put screening with microplate readers.

It is important to also critically asses the value of the meth-odology: can useful data be derived and is it relevant to real biological in vitro and in vivo experiments? Therefore, the remaining discussion will focus on the significance of the ini-tial results with respect to the research field of ‘plasma medi-cine’, as well as limitations of the methodology and scope for further improvements.

The major result was that plasma jets have the potential to damage DNA in tissue fluid, tissue and cell models. This is not surprising because as discussed earlier, plasma jets generate highly-reactive RONS that have previously been shown to break DNA-strands [78–82]. In the treatment of life-threatening indications such as cancers and chronic wounds, it would be advantageous to target the destruction of cancerous cells within tumours or bacterial cells within biofilms using plasma jets to damage DNA in these cell types. For life-threatening indications, any risk associated with respect to inadvertent DNA damage in healthy cells (in the surrounding tissue) is perhaps reasonably low considering that not all DNA aberrations cause disease and the cellular machinery of healthy cells is well equipped to repair most damaged DNA [87, 88]. On the other hand, the data in this study suggest that given there are always DNA-strand breaks (in direct applica-tion of plasma to the tissue fluid model) there remains some level of potential risk, and in such a case the risk ought to be factored in when considering non-critical clinical applications of plasma jets such as for cosmetics (e.g. wrinkle treatments and teeth whitening).

Targeted DNA damage with plasma jets could be the objec-tive in the treatment of cancer. Often elevated levels of DNA damage are linked to an increase in frequency of cancer cell death induced by plasma jets in vitro [35, 89]. This is a similar approach to that adopted with ionising radiation therapy in that damaged DNA in the cell blocks further cell prolifera-tion; and the key is to target the radiation to the diseased tissue only [90]. However, despite ongoing advances in techniques utilised for ionising radiation therapy, 95% of patients who receive ionising radiation therapy consequently suffer from skin damage [91]. In this respect plasma has an advantage over ionising radiation in that it generally does not damage skin. Another potential advantage is that plasma jets can be highly targeted to treat cancer cells [92] with the miniaturisation of the plasma jet nozzle down to nanometre dimensions [93]. In addition to the plasma jet induced breakage of DNA-strands in HEPES (tissue fluid model), the plasma jet also induced DNA-strand breaks in gelatin (tissue model). This demonstrates that it might be possible to use plasma jets to damage DNA in a solid tissue mass such as a tumour. Importantly, the plasma jet is unlikely to cause DNA damage far underneath a tumour because no DNA damage was observed in HEPES underneath the gelatin target. Overall, these data show that plasma jets could potentially be utilised in the future to damage DNA at specific sites within tissue for targeted cancer therapy.

Another potentially interesting observation is that the lower flow rate (0.05 slpm) plasma jet induced more DNA-strand breaks compared to the higher flow rate (0.5 slpm) plasma jet when the MB was suspended in HEPES; whereas the opposite trend was observed when the MB was encapsulated within

Figure 8. Assessment of DNA-strand breaks in the tissue fluid model after plasma jet treatment through a hydrogel dressing (IntraSite Conformable) and the corresponding H2O2 concentration generated in the tissue fluid model underneath the hydrogel dressing. (a) Photograph during plasma jet treatment through the hydrogel dressing and (b) schematic representation of the experimental set-up. (c) Result of DNA-strand breaks and corresponding H2O2 concentration for the same plasma jet treatment. The plasma jet was operated at 0.5 slpm He and the treatment time was 10 min.

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 12: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

11

vesicles. We propose three not mutually exclusive explana-tions for the opposing trends. We start from the premise that H2O2 does not induce DNA-strand breaks. Therefore, we suspect that it is short-lived, highly-reactive RONS that are responsible for the observed DNA-strand breaks. Treatment of MBs in HEPES with the lower flow rate, but substantially longer treatment times, results in greater damage of the MB than at the higher flow rates (at much reduced treatment times) because the total number of interactions between the short-lived, highly-reactive RONS and MBs is greater in the former case. But when the MB is encapsulated, these highly-reactive RONS most probably react almost entirely with the vesicle’s phospholipid membrane before reaching the DNA within. Therefore, we propose the reversed result arises because:

(1) The higher H2O2 concentration generated by the higher flow rate plasma jet becomes important as it facilitates the oxidation [94, 95] and permeabilisation of the phos-pholipid membrane, which enhanced the ingress of any remaining highly-reactive RONS [55];

(2) The higher flow rate plasma jet extends the plasma jet to contact the liquid, which should increase the electric field around the vesicles. The maximum electric field generated by the plasma jet in this study is 2.5 kV cm−1. Although not investigated in this study, we know similar plasma jets generate small packets of charge (usually referred to as ‘plasma bullets’) that carry a net charge in the order of 10–9 C with estimated particle densities between 1010–1011 cm−3 that can propagate to distances of several tens of millimetres from the plasma jet nozzle [96]. This phenomenon is usually described as an ‘ionisation front’ and has been termed a ‘guided streamer’ because its propagation is confined to within the He gas flow exiting the plasma jet nozzle [97, 98]. The magnitude of the peak streamer head electric field has been reported to be up to ~5–7 kV cm−1 [97]. A further increase in electric field from the ‘plasma bullets’ contacting the HEPES might have transiently increased the permeability of the phos-pholipid membrane during plasma jet treatment. This would enhance the ingress of the highly-reactive RONS. Previously, in a computational simulation study, Yusupov et al has shown that the synergistic action of electric field with H2O2 potentially increases phospholipid membrane permeability that increases the ingress of RONS into cells [54]. This perhaps occurs on a very fast time-scale with only small nanometre diameter pore openings in the phospholipid membrane [99]. This would explain only minimal leakage of the encapsulated CF from the vesicles with plasma jet treatment.

(3) The gas flow itself imparts greater mechanical forces onto the phospholipid membrane of the vesicles [100]. Consequently, greater mechanical forces exerted onto the phospholipid membrane by the higher flow rate plasma jet, enhanced the ingress of RONS.

We should note that it is necessary to also assess how the plasma jet treatment might affect the DNA and phospholipid membrane in the longer term. This will require more detailed experimentation that is outside the scope of this present study.

But we can reasonably speculate based on the present data and results from our previous studies. With respect to DNA damage, any direct DNA-strand breaks induced by the plasma jet would be permanent, but further DNA strand breaks would not be expected to occur in the longer term as the highly-reactive RONS would be extinguished rapidly after comple-tion of the plasma jet treatment. In a ‘real’ cell, the cellular machinery can repair damaged DNA [87, 88]. However, fur-ther DNA aberrations could result in the longer term if cell function such as the cell cycle is altered by the plasma jet treatment. With respect to modifications of the phospholipid membrane, our data to date indicate that the increased per-meability of the phospholipid membrane vesicles to RONS after plasma jet treatment is permanent. This enables the ingress of longer-lived RONS many hours after completion of the plasma jet treatment [48, 49]. However, it is difficult to ascertain if the longer term increased permeability of the phospholipid membrane to RONS is attributed to the initial plasma jet treatment or the fact that longer-lived RONS (e.g. H2O2) remain in the solution for many hours after the plasma jet treatment. Once again, in a ‘real’ cell the effects are likely to be different. Through evolution cells have developed mech-anisms for repairing membranes [101].

In certain circumstances, such as stimulation of wound healing or tissue regeneration, it could be advantageous to only deliver RONS that stimulate cell activity (e.g. prolifera-tion and migration). In this study, we have seen that a hydrogel dressing placed in-between the plasma jet and HEPES or gelatin targets can significantly attenuate DNA-strand breaks but still enable the transport of H2O2 (and by inference other longer-lived RONS) to the targets. Delivery of controlled doses of H2O2 was previously shown to have beneficial effects on wound healing in vivo [102]. Plasma jet treatment through a hydrogel dressing is a simple method to potentially stimu-late wound healing with the added advantage of not needing to remove the dressing for treatment.

Having considered the advantages, it is worth considering the limitations of the methodology we report, which we dis-cuss with a view to future improvements. The major limita-tions are that the tissue fluid, tissue and cell models are without real biological material, antioxidants and living cells, and the system is static with no physiological fluid flow. Therefore, the level of DNA-strand breaks observed in this study could be considered as a worst case scenario. The physicochemical properties and inherent antioxidant defences of real biolog-ical tissue fluid and tissue would to some extent mitigate the transport of the RONS likely to induce DNA-strand breaks. Additional features that could be in-built to models include the incorporation of proteins, enzymes and antioxidants and cross-linking agents. These could be incorporated into either the tissue fluid or tissue models to mimic different physio-logical environments. In addition, it is possible to incorporate living cells into, for example, a mimic of a 3D tumour [103, 104]. This would enable us to study cellular signalling events within a solid tumour; intercellular signalling might also facil-itate the plasma-generated signal to reach cells deeper within the tumour, which could potentially amplify DNA damage. It should also be possible to incorporate fluidic systems with

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 13: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

12

small pumping systems to mimic physiological flow. These features could be incorporated into the future design of the synthetic models to help improve our understanding of plasma interactions with biological systems.

5. Conclusions and future directions

A methodology is established to assess DNA-strand breaks induced by a He plasma jet in synthetic models of tissue fluid, tissue and cells. The plasma jet induced DNA-strand breaks in the tissue fluid and tissue models. DNA-strand breaks were also detected in the cell model without significant pora-tion or rupture of the phospholipid membrane. DNA-strand breaks were significantly reduced in the tissue fluid when a hydrogel dressing was situated in-between the plasma jet and tissue fluid during treatment, but H2O2 (and potentially other RONS not measured) could still be transported through the dressing. The synthetic models could be improved in the future to mimic more realistic biological systems. But major advantages of the methodology are its cost effectiveness and it affords rapid analysis of DNA-strand breaks in different pseudo biological environments. Developing a more detailed understanding of plasma-DNA interactions in different bio-logical environments should help the future development of plasma medical therapies.

Acknowledgments

EJS, S-HH, NG, AJC and RDS would like to acknowledge the support of the Australian Government’s Cooperative Research Centres Program and the Wound Management Innovation CRC for partially supporting this research through project SP09-02, and the Australian Research Council through the Discovery Project DP16010498. HK thanks JSPS KAKENHI 26390096 and the Smoking Research Foundation. JSO and AH thank for the Priority Research Grant of Kochi Univer-sity of Technology. JSO and MI thank JSPS KAKENHI Grant No. 26286072 and the Promoting Research Center in Meijo University. AM thanks KAKENHI 24108005 from MEXT. DBG acknowledges partial support from the US DoE Office of Fusion Energy Sciences under Grant DE-SC0001939. The authors would like to thank Ki-Jong Kang for the illustrations and Dr Suet Low for the photographs.

References

[1] Mohd Nasir N, Lee B K, Yap S S, Thong K L and Yap S L 2016 Cold plasma inactivation of chronic wound bacteria Arch. Biochem. Biophys. 605 76–85

[2] Kalghatgi S, Friedman G, Fridman A and Clyne A 2010 Endothelial cell proliferation is enhanced by low dose non-thermal plasma through fibroblast growth factor-2 release Ann. Biomed. Eng. 38 748–57

[3] Miller V, Lin A, Fridman G, Dobrynin D and Fridman A 2014 Plasma stimulation of migration of Macrophages Plasma Process. Polym. 11 1193–7

[4] Arjunan K P, Friedman G, Fridman A and Clyne A M 2012 Non-thermal dielectric barrier discharge plasma induces

angiogenesis through reactive oxygen species J. R. Soc. Interface 9 147–57

[5] Arjunan K P and Clyne A M 2011 A nitric oxide producing pin-to-hole spark discharge plasma enhances endothelial cell proliferation and migration Plasma Med. 1 279–93

[6] Oh J-S et al 2016 How plasma induced oxidation, oxygenation, and de-oxygenation influences viability of skin cells Appl. Phys. Lett. 109 203701

[7] Szili E J, Harding F J, Hong S-H, Herrmann F, Voelcker N H and Short R D 2015 The hormesis effect of plasma-elevated intracellular ROS on HaCaT cells J. Phys. D: Appl. Phys. 48 495401

[8] Nasruddin, Nakajima Y, Mukai K, Rahayu H S E, Nur M, Ishijima T, Enomoto H, Uesugi Y, Sugama J and Nakatani T 2014 Cold plasma on full-thickness cutaneous wound accelerates healing through promoting inflammation, re-epithelialization and wound contraction Clin. Plasma Med. 2 28–35

[9] Kalghatgi S, Kelly C M, Cerchar E, Torabi B, Alekseev O, Fridman A, Friedman G and Azizkhan-Clifford J 2011 Effects of non-thermal plasma on mammalian cells PLoS One 6 e16270

[10] Park C H et al 2014 Wound healing with nonthermal microplasma jets generated in arrays of hourglass microcavity devices J. Phys. D: Appl. Phys. 47 435402

[11] Nastuta A V, Topala I, Grigoras C, Pohoata V and Popa G 2011 Stimulation of wound healing by helium atmospheric pressure plasma treatment J. Phys. D: Appl. Phys. 44 105204

[12] Ermolaeva S A et al 2011 Bactericidal effects of non-thermal argon plasma in vitro, in biofilms and in the animal model of infected wounds J. Med. Microbiol. 60 75–83

[13] Hammann A et al 2010 Antiseptic efficacy and tolerance of tissue-tolerable plasma compared with two wound antiseptics on artificially bacterially contaminated eyes from commercially slaughtered pigs Skin Pharmacol. Physiol. 23 328–32

[14] Joshi S G, Cooper M, Yost A, Paff M, Ercan U K, Fridman G, Friedman G, Fridman A and Brooks A D 2011 Nonthermal dielectric-barrier discharge plasma-induced inactivation involves oxidative DNA damage and membrane lipid peroxidation in Escherichia coli Antimicrob. Agents Chemother. 55 1053–62

[15] Nosenko T, Shimizu T and Morfill G E 2009 Designing plasmas for chronic wound disinfection New J. Phys. 11 115013

[16] Laroussi M and Leipold F 2004 Evaluation of the roles of reactive species, heat, and UV radiation in the inactivation of bacterial cells by air plasmas at atmospheric pressure Int. J. Mass Spectrom. 233 81–6

[17] Kim S J, Chung T H, Bae S H and Leem S H 2009 Characterization of atmospheric pressure microplasma jet source and its application to bacterial inactivation Plasma Process. Polym. 6 676–85

[18] Laroussi M, Tendero C, Lu X, Alla S and Hynes W L 2006 Inactivation of bacteria by the plasma pencil Plasma Process. Polym. 3 470–3

[19] Laroussi M, Richardson J P and Dobbs F C 2002 Effects of nonequilibrium atmospheric pressure plasmas on the heterotrophic pathways of bacteria and on their cell morphology Appl. Phys. Lett. 81 772

[20] Kim P Y, Kim Y-S, Koo I G, Jung J C, Kim G J, Choi M Y, Yu Z and Collins G J 2011 Bacterial inactivation of wound infection in a human skin model by liquid-phase discharge plasma PLoS One 6 e24104

[21] Alkawareek M Y, Algwari Q T, Laverty G, Gorman S P, Graham W G, O’Connell D and Gilmore B F 2012 Eradication of Pseudomonas aeruginosa biofilms by atmospheric pressure non-thermal plasma PLoS One 7 e44289

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 14: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

13

[22] Xu G-M, Shi X-M, Cai J-F, Chen S-L, Li P, Yao C-W, Chang Z-S and Zhang G-J 2015 Dual effects of atmospheric pressure plasma jet on skin wound healing of mice Wound Repair Regen. 23 878–84

[23] Heinlin J et al 2013 Randomized placebo-controlled human pilot study of cold atmospheric argon plasma on skin graft donor sites Wound Repair Regen. 21 800–7

[24] Isbary G et al 2013 Cold atmospheric argon plasma treatment may accelerate wound healing in chronic wounds: results of an open retrospective randomized controlled study in vivo Clin. Plasma Med. 1 25–30

[25] Isbary G et al 2012 Successful and safe use of 2 min cold atmospheric argon plasma in chronic wounds: results of a randomized controlled trial Br. J. Dermatol. 167 404–10

[26] Isbary G et al 2010 A first prospective randomized controlled trial to decrease bacterial load using cold atmospheric argon plasma on chronic wounds in patients Br. J. Dermatol. 163 78–82

[27] Laroussi M, Mohades S and Barekzi N 2015 Killing adherent and nonadherent cancer cells with the plasma pencil Biointerphases 10 029401

[28] Ishaq M, Evans M and Ostrikov K 2014 Effect of atmospheric gas plasmas on cancer cell signaling Int. J. Cancer 134 1517–28

[29] Ma Y, Ha C S, Hwang S W, Lee H J, Kim G C, Lee K-W and Song K 2014 Non-thermal atmospheric pressure plasma preferentially induces apoptosis in p53-mutated cancer cells by activating ROS stress-response pathways PLoS One 9 e91947

[30] Barekzi N and Laroussi M 2013 Effects of low temperature plasmas on cancer cells Plasma Process. Polym. 10 1039–50

[31] Kumar N, Park J H, Jeon S N, Park B S, Choi E H and Attri P 2016 The action of microsecond-pulsed plasma-activated media on the inactivation of human lung cancer cells J. Phys. D: Appl. Phys. 49 115401

[32] Gibson A R, McCarthy H O, Ali A A, O’Connell D and Graham W G 2014 Interactions of a non-thermal atmospheric pressure plasma effluent with PC-3 prostate cancer cells Plasma Process. Polym. 11 1142–9

[33] Vandamme M, Robert E, Pesnel S, Barbosa E, Dozias S, Sobilo J, Lerondel S, Le Pape A and Pouvesle J-M 2010 Antitumor effect of plasma treatment on U87 glioma xenografts: preliminary results Plasma Process. Polym. 7 264–73

[34] Keidar M, Walk R, Shashurin A, Srinivasan P, Sandler A, Dasgupta S, Ravi R, Guerrero-Preston R and Trink B 2011 Cold plasma selectivity and the possibility of a paradigm shift in cancer therapy Br. J. Cancer 105 1295–301

[35] Keidar M, Shashurin A, Volotskova O, Stepp M A, Srinivasan P, Sandler A and Trink B 2013 Cold atmospheric plasma in cancer therapy Phys. Plasmas 20 057101–8

[36] Metelmann H-R et al 2015 Head and neck cancer treatment and physical plasma Clin. Plasma Med. 3 17–23

[37] Fluhr J W, Sassning S, Lademann O, Darvin M E, Schanzer S, Kramer A, Richter H, Sterry W and Lademann J 2012 In vivo skin treatment with tissue-tolerable plasma influences skin physiology and antioxidant profile in human stratum corneum Exp. Dermatol. 21 130–4

[38] Metelmann H-R et al 2013 Scar formation of laser skin lesions after cold atmospheric pressure plasma (CAP) treatment: a clinical long term observation Clin. Plasma Med. 1 30–5

[39] Graves D B 2012 The emerging role of reactive oxygen and nitrogen species in redox biology and some implications for plasma applications to medicine and biology J. Phys. D: Appl. Phys. 45 263001

[40] Stoffels E, Sakiyama Y and Graves D B 2008 Cold atmospheric plasma: charged species and their interactions with cells and tissues IEEE Trans. Plasma Sci. 36 1441–57

[41] Dobrynin D, Fridman G, Friedman G and Fridman A 2009 Physical and biological mechanisms of direct plasma interaction with living tissue New J. Phys. 11 115020

[42] Oh J-S, Szili E J, Gaur N, Hong S-H, Furuta H, Kurita H, Mizuno A, Hatta A and Short R D 2016 How to assess the plasma delivery of RONS into tissue fluid and tissue J. Phys. D: Appl. Phys. 49 304005

[43] Oh J-S, Szili E J, Ito S, Hong S-H, Gaur N, Furuta H, Short R D and Hatta A 2015 Slow molecular transport of plasma-generated reactive oxygen and nitrogen species and O2 through agarose as a surrogate for tissue Plasma Med. 5 125–43

[44] Oh J-S, Szili E J, Gaur N, Hong S-H, Furuta H, Short R D and Hatta A 2015 In situ UV absorption spectroscopy for monitoring transport of plasma reactive species through agarose as surrogate for tissue J. Photopolym. Sci. Technol. 28 439–44

[45] Gaur N, Szili E J, Oh J-S, Hong S-H, Michelmore A, Graves D B, Hatta A and Short R D 2015 Combined effect of protein and oxygen on reactive oxygen and nitrogen species in the plasma treatment of tissue Appl. Phys. Lett. 107 103703

[46] Szili E J, Hong S-H and Short R D 2015 On the effect of serum on the transport of reactive oxygen species across phospholipid membranes Biointerphases 10 029511

[47] Szili E J, Oh J-S, Hong S-H, Hatta A and Short R D 2015 Probing the transport of plasma-generated RONS in an agarose target as surrogate for real tissue: dependency on time, distance and material composition J. Phys. D: Appl. Phys. 48 202001

[48] Hong S-H, Szili E J, Jenkins A T A and Short R D 2015 Corrigendum: Ionized gas (plasma) delivery of reactive oxygen species (ROS) into artificial cells (2014 J. Phys. D. Appl. Phys. 47 362001) J. Phys. D: Appl. Phys. 48 029501

[49] Hong S-H, Szili E J, Jenkins A T A and Short R D 2014 Ionized gas (plasma) delivery of reactive oxygen species (ROS) into artificial cells J. Phys. D: Appl. Phys. 47 362001

[50] Szili E J, Bradley J W and Short R D 2014 A ‘tissue model’ to study the plasma delivery of reactive oxygen species J. Phys. D: Appl. Phys. 47 152002

[51] He T, Liu D, Xu H, Liu Z, Xu D, Li D, Li Q, Rong M and Kong M G 2016 A ‘tissue model’ to study the barrier effects of living tissues on the reactive species generated by surface air discharge J. Phys. D: Appl. Phys. 49 205204

[52] Kawasaki T, Sato A, Kusumegi S, Kudo A, Sakanoshita T, Tsurumaru T, Uchida G, Koga K and Shiratani M 2016 Two-dimensional concentration distribution of reactive oxygen species transported through a tissue phantom by atmospheric-pressure plasma-jet irradiation Appl. Phys. Express 9 076202

[53] Ki S H, Park J K, Sung C, Lee C B, Uhm H, Choi E H and Baik K Y 2016 Artificial vesicles as an animal cell model for the study of biological application of non-thermal plasma J. Phys. D: Appl. Phys. 49 085401

[54] Yusupov M, Van der Paal J, Neyts E C and Bogaerts A 2017 Synergistic effect of electric field and lipid oxidation on the permeability of cell membranes Biochim. Biophys. Acta—Gen. Subjects 1861 839–47

[55] Van der Paal J, Neyts E C, Verlackt C C W and Bogaerts A 2016 Effect of lipid peroxidation on membrane permeability of cancer and normal cells subjected to oxidative stress Chem. Sci. 7 489–98

[56] Bogaerts A, Khosravian N, Van der Paal J, Verlackt C C W, Yusupov M, Kamaraj B and Neyts E C 2016 Multi-level molecular modelling for plasma medicine J. Phys. D: Appl. Phys. 49 054002

[57] Bogaerts A, Yusupov M, Van der Paal J, Verlackt C C W and Neyts E C 2014 Reactive molecular dynamics simulations

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 15: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

14

for a better insight in plasma medicine Plasma Process. Polym. 11 1156–68

[58] Neyts E C, Yusupov M, Verlackt C C and Bogaerts A 2014 Computer simulations of plasma–biomolecule and plasma–tissue interactions for a better insight in plasma medicine J. Phys. D: Appl. Phys. 47 293001

[59] van der Paal J V, Aernouts S, van Duin A C T, Neyts E C and Bogaerts A 2013 Interaction of O and OH radicals with a simple model system for lipids in the skin barrier: a reactive molecular dynamics investigation for plasma medicine J. Phys. D: Appl. Phys. 46 395201

[60] Tian W and Kushner M J 2014 Atmospheric pressure dielectric barrier discharges interacting with liquid covered tissue J. Phys. D: Appl. Phys. 47 165201

[61] Chen C, Liu D X, Liu Z C, Yang A J, Chen H L, Shama G and Kong M G 2014 A model of plasma-biofilm and plasma-tissue interactions at ambient pressure Plasma Chem. Plasma Process. 34 403–41

[62] Halliwell B and Gutteridge J M C 2007 Free Radicals in Biology and Medicine 4th edn (Oxford: Oxford Univeristy Press)

[63]Brun P et al 2012 Disinfection of ocular cells and tissues by atmospheric-pressure cold plasma PLoS One 7 e33245

[64] Graves D B 2014 Oxy-nitroso shielding burst model of cold atmospheric plasma therapeutics Clin. Plasma Med. 2 38–49

[65] Viebahn-Hänsler R, León Fernández O S and Fahmy Z 2012 Ozone in medicine: the low-dose ozone concept—guidelines and treatment strategies Ozone: Sci. Eng. 34 408–24

[66] Heinlin J, Isbary G, Stolz W, Morfill G, Landthaler M, Shimizu T, Steffes B, Nosenko T, Zimmermann J L and Karrer S 2011 Plasma applications in medicine with a special focus on dermatology J. Eur. Acad. Dermatol. Venereol. 25 1–11

[67] Robert E, Darny T, Dozias S, Iseni S and Pouvesle J M 2015 New insights on the propagation of pulsed atmospheric plasma streams: from single jet to multi jet arrays Phys. Plasmas 22 122007

[68] von Woedtke T, Reuter S, Masur K and Weltmann K D 2013 Plasmas for medicine Phys. Rep. 530 291–320

[69] Lu X, Naidis G V, Laroussi M, Reuter S, Graves D B and Ostrikov K 2016 Reactive species in non-equilibrium atmospheric-pressure plasmas: generation, transport, and biological effects Phys. Rep. 630 1–84

[70] Wende K, Bekeschus S, Schmidt A, Jatsch L, Hasse S, Weltmann K D, Masur K and von Woedtke T 2016 Risk assessment of a cold argon plasma jet in respect to its mutagenicity Mutat. Res. 798–9 48–54

[71] Kluge S, Bekeschus S, Bender C, Benkhai H, Sckell A, Below H, Stope M B and Kramer A 2016 Investigating the mutagenicity of a cold argon-plasma jet in an HET-MN model PLoS One 11 e0160667

[72] Bekeschus S, Schmidt A, Weltmann K-D and von Woedtke T 2016 The plasma jet kINPen—A powerful tool for wound healing Clin. Plasma Med. 4 19–28

[73] Samukawa S et al 2012 The 2012 plasma roadmap J. Phys. D: Appl. Phys. 45 253001

[74] Tresp H, Hammer M U, Winter J, Weltmann K-D and Reuter S 2013 Quantitative detection of plasma-generated radicals in liquids by electron paramagnetic resonance spectroscopy J. Phys. D: Appl. Phys. 46 435401

[75] Oehmigen K, Winter J, Hähnel M, Wilke C, Brandenburg R, Weltmann K-D and von Woedtke T 2011 Estimation of possible mechanisms of Escherichia coli inactivation by plasma treated sodium chloride solution Plasma Process. Polym. 8 904–13

[76] Ames B N, Shigenaga M K and Hagen T M 1993 Oxidants, antioxidants, and the degenerative diseases of aging Proc. Natl Acad. Sci. USA 90 7915–22

[77] Szabó C and Ohshima H 1997 DNA damage induced by peroxynitrite: subsequent biological effects Nitric Oxide 1 373–85

[78] Kurita H, Shimizu M, Sano K, Nakajima T, Yasuda H, Takashima K and Mizuno A 2014 Radical reaction in aqueous media injected by atmospheric pressure plasma jet and protective effect of antioxidant reagents evaluated by single-molecule DNA measurement Japan. J. Appl. Phys. 53 05FR01

[79] Kurita H, Nakajima T, Yasuda H, Takashima K, Mizuno A, Wilson J I B and Cunningham S 2011 Single-molecule measurement of strand breaks on large DNA induced by atmospheric pressure plasma jet Appl. Phys. Lett. 99 191504

[80] Kurita H, Miyachika S, Yasuda H, Takashima K and Mizuno A 2015 Use of molecular beacons for the rapid analysis of DNA damage induced by exposure to an atmospheric pressure plasma jet Appl. Phys. Lett. 107 263702

[81] Yasuda H, Hashimoto M, Rahman M M, Takashima K and Mizuno A 2008 States of biological components in bacteria and bacteriophages during inactivation by atmospheric dielectric barrier discharges Plasma Process. Polym. 5 615–21

[82] Yasuda H, Miura T, Kurita H, Takashima K and Mizuno A 2010 Biological evaluation of DNA damage in bacteriophages inactivated by atmospheric pressure cold plasma Plasma Process. Polym. 7 301–8

[83] van Meer G, Voelker D R and Feigenson G W 2008 Membrane lipids: where they are and how they behave Nat. Rev. Mol. Cell. Biol. 9 112–24

[84] Darny T, Pouvesle J M, Puech V, Douat C, Dozias S and Eric R 2017 Analysis of conductive target influence in plasma jet experiments through helium metastable and electric field measurements Plasma Sources Sci. Technol. 26 045008

[85] Verlackt C C W, Neyts E C, Jacob T, Fantauzzi D, Golkaram M, Shin Y K, van Duin A C T and Bogaerts A 2015 Atomic-scale insight into the interactions between hydroxyl radicals and DNA in solution using the ReaxFF reactive force field New J. Phys. 17 103005

[86] Marshall S E, Jenkins A T A, Al-Bataineh S A, Short R D, Hong S-H, Thet N T, Oh J-S, Bradley J W and Szili E J 2013 Studying the cytolytic activity of gas plasma with self-signalling phospholipid vesicles dispersed within a gelatin matrix J. Phys. D: Appl. Phys. 46 185401

[87] Taylor E M, Cecillon S M, Bonis A, Chapman J R, Povirk L F and Lindsay H D 2010 The Mre11/Rad50/Nbs1 complex functions in resection-based DNA end joining in Xenopus laevis Nucleic Acids Res. 38 441–54

[88] Taylor E M and Lindsay H D 2015 DNA replication stress and cancer: cause or cure? Future Oncol. 12 221–37

[89] Kaushik N K, Uhm H and Choi E H 2012 Micronucleus formation induced by dielectric barrier discharge plasma exposure in brain cancer cells Appl. Phys. Lett. 100 084102

[90] Baskar R, Lee K A, Yeo R and Yeoh K-W 2012 Cancer and radiation therapy: current advances and future directions Int. J. Med. Sci. 9 193–9

[91] Ryan J L 2012 Ionizing radiation: the good, the bad, and the ugly J. Invest. Dermatol. 132 985–93

[92] Kim J Y, Wei Y, Li J, Foy P, Hawkins T, Ballato J and Kim S-O 2011 Single-cell-level microplasma cancer therapy Small 7 2291–5

[93] Kakei R, Ogino A, Iwata F and Nagatsu M 2010 Production of ultrafine atmospheric pressure plasma jet with nano-capillary Thin Solid Films 518 3457–60

J. Phys. D: Appl. Phys. 50 (2017) 274001

Page 16: The assessment of cold atmospheric plasma treatment of DNA ...

E J Szili et al

15

[94] Siddique Y H, Ara G and Afzal M 2012 Estimation of lipid peroxidation induced by hydrogen peroxide in cultured human lymphocytes Dose–Response 10 1–10

[95] Sakharov D V, Elstak E D R, Chernyak B and Wirtz K W 2005 A Prolonged lipid oxidation after photodynamic treatment. Study with oxidation-sensitive probe C11-BODIPY581/591 FEBS Lett. 579 1255–60

[96] Oh J-S, Walsh J L and Bradley J W 2012 Plasma bullet current measurements in a free-stream helium capillary jet Plasma Sources Sci. Technol. 21 034020

[97] Olszewski P, Wagenaars E, McKay K, Bradley J W and Walsh J L 2014 Measurement and control of the streamer head electric field in an atmospheric-pressure dielectric barrier plasma jet Plasma Sources Sci. Technol. 23 015010

[98] Boeuf J P, Yang L L and Pitchford L C 2013 Dynamics of a guided streamer (‘plasma bullet’) in a helium jet in air at atmospheric pressure J. Phys. D: Appl. Phys. 46 015201

[99] Tero R, Yamashita R, Hashizume H, Suda Y, Takikawa H, Hori M and Ito M 2016 Nanopore formation process in

artificial cell membrane induced by plasma-generated reactive oxygen species Arch. Biochem. Biophys. 605 26–33

[100] Cooper S, Jonak P, Chouinard-Pelletier G, Coulombe S, Jones E and Leask R L 2013 Permeabilization of adhered cells using an inert gas jet J. Vis. Exp. 79 e50612

[101] Davies K J A 2000 Oxidative stress, antioxidant defenses, and damage removal, repair, and replacement systems IUBMB Life 50 279–89

[102] Loo A E K, Wong Y T, Ho R, Wasser M, Du T, Ng W T and Halliwell B 2012 Effects of hydrogen peroxide on wound healing in mice in relation to oxidative damage PLoS One 7 e49215

[103] Shin C S, Kwak B, Han B and Park K 2013 Development of an in vitro 3D tumor model to study therapeutic efficiency of an anticancer drug Mol. Pharm. 10 2167–75

[104] Fang J Y, Tan S-J, Yang Z, Tayag C and Han B 2014 Tumor bioengineering using a transglutaminase crosslinked hydrogel PLoS One 9 e105616