Transcript
Page 1: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5
Page 2: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

The shaded areas of the map indicate ESCAP members and associate members

The Centre for Sustainable Agricultural Mechanization (CSAM), is a regional institution of the United Nations Economic and Social Commission for Asia and the Pacific (ESCAP), based in Beijing, China. CSAM started operations in 2004, building on the achievements of the Regional Network for Agricultural Machinery (RNAM) and the United Nations Asian and Pacific Centre for Agricultural Engineering and Machinery (UNAPCAEM). CSAM serves the 62 members and associate members of ESCAP.

The vision of CSAM is to achieve production gains, improved rural livelihood and poverty alleviation through sustainable agricultural mechanization for a more resilient, inclusive and sustainable Asia and the Pacific.

The Secretariat of the Asian and Pacific Network for Testing of Agricultural Machinery (ANTAM) is based at CSAM. CSAM is the executing agency of ANTAM. The ANTAM Secretariat assists and coordinates the operation of the network, and provides necessary logistical and administrative support.

The designations used and the presentation of the material in this publication do not imply the expression of any opinion on the part of the ESCAP Secretariat concerning the delimitation of its frontiers or boundaries. Any mention of firm

names and commercial products do not imply the endorsement of ESCAP/CSAM.

Page 3: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

Approval Number:

Date of Approval:

Report on test in accordance with ANTAM Test Code (Please insert number of the Code)

Make /model of machine

Testing station report number The date reported on completion of the test

PHOTO of the Machine

Testing station -Name -Address -Contact

Page 4: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

Remarks

• This test report provides the results of the tests conducted in accordance with

the ANTAM Test Codes as per version provided in cover page.

• This report is invalid without the official stamp of ANTAM.

• Any amendment to this document is not allowed.

• The data given in this report pertain to the particular machine submitted by the

applicant for test.

Page 5: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

Product: Misters-cum-dusters

Make

Model

Trade Mark

ANTAM Test Code & Version

Authorized test center

Name

Address

Contact Details

Test Location

Manufacturer

Name and Address

Contact Details

Applicant Name and Address

Contact Details

Period of Test

Month/ Year

Number of samples

Date of Manufacturing

Serial numbers of machines

(highlight the serial numbers

of the machine corresponding

to the test results)

1.

2.

3.

Date of Receipt

Submitted by

Name

Contact No.

Received by

Name

Contact No.

Page 6: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

Page 7: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

SELECTED CONVERSIONS

S. No Units Conversion Factor

1 Force

1 kgf 9.80665 N

2.20462 lbf

2 Power

1 hp 1.01387 metric hp (ps)

745.7 W

1 ps 735.5 W

1 kW 1.35962 ps

3 Pressure

1 psi 6.895 kPa

1 kgf/cm2 98.067 kPa = 735.56 mm of

Hg

1 bar 100 kPa = 10 N/cm2

1 mm of Hg 1.3332 m-bar

Page 8: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

TABLE OF CONTENT

S. No. Particulars Page

1. Checking of Spécifications

2. Test Results

2.1 Component Test

2.2 Performance Test

2.3 Safety and Endurance Test

3. Remarks and suggestions

1. CHECKING OF SPECIFICATIONS

S. No.

GENERAL Specifications

1.0

Overall Dimensions (length x width x height) (mm)

1.1

Net Weight (without liquid/dust) (kg)

1.2

ENGINE

Testing center should verify the following engine

parameters, either from manufacturer data or by testing

of the engine in the testing center.

Note: For China, it is mandatory to follow the standards

JB/T 5135.1 -2013.Engine Certification Number:

1.2.1 Make/Type/Model/Country

1.2.2 Serial Number

1.2.3 Engine (manufacturer’s recommended settings)

- Type

- Make/brand

- Model

- Country of Manufacture

- Serial number

- Rated speed (rpm)

- Power at rated speed (kW)

- Specific fuel consumption (g/kWh)

- Maximum torque (Nm)

Page 9: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

1.2.4 Type of fuel used (Octane Number)

1.2.5 Fuel tank Capacity (l)

1.2.6 Presence of strainer at engine tank inlet Y / N

1.2.7 Type of fuel filter

1.2.8 Starting system:

- Type

- Aids for cold starting, if any

- Any other device provided for easy starting

1.3 TYPE OF PUMP

1.4 FRAME

1.4.1 Material of construction

1.4.2 Size (Width x Height x Length) (mm)

1.5 TANK

1.5.1 Shape (Trapezoidal/Cylindrical/Any other)

1.5.2 Size:

(Trapezoidal: Width x Height x Depth) (mm)

(Cylindrical: Diameter x Length) (mm)

1.5.3 Tank capacity (l)

1.5.4 Material of construction

1.5.5 Size of liquid filling hole (mm)

1.5.6 Strainer or filter mesh size (mm)

1.5.7 Tank level demarcation

1.5.8 Extra volume of 7.5% Y / N

1.6 BACK REST

1.6.1 Size (Width x Height x Thickness) (mm)

1.6.2 Material

1.7 STRAP

1.7.1 Material of strap

1.7.2 Material of strap buckle

1.7.3 Quick release mechanism

1.7.4 Width and thickness of strap (mm)

1.7.5 Minimum and maximum strap length can be used (mm)

1.8 MISTING/DUSTING DUCT

1.8.1 Types of misting/dusting duct equipped

1.8.2 Misting/Dusting duct internal diameter and length (mm)

1.8.3 Air hose: length and internal diameter / (mm)

1.8.4 Presence of air flow regulator Y / N

1.9 BLOWER

1.9.1 Impeller type: fully enclosed / partially enclosed

1.9.2 Impeller type: fully enclosed / partially enclosed

- Material

- Diameter / (mm)

1.9.3 Impeller blade type: forward bent / radial / backward

bent

Number of blades

1.10 DETAILS OF AGITATING DEVICE PROVIDED (if

any)

1.11 LIST OF STANDARD ACCESSORIES/PARTS

PROVIDED WITH EQUIPMENT

(provide as annex)

1.12 PUBLICATIONS

- Operator’s manual

- Service manual

- Parts catalogue

- Safety precautions

Comply / Not comply

Comply / Not comply

Comply / Not comply

Comply / Not comply

Page 10: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

2. TEST RESULTS

2.1 COMPONENT TEST

S. No. Particulars Performance Specification Test Result Remarks

2.1.1 Leakage test of

the whole

machine

Every component shall be tightly

sealed without leakage.

2.1.2 Chemical tank

leakage test

Maintained pressure of 10 kPa

during 1 min without leakage

2.1.3 Blower fan over

speed test

Blower fan tested at 1.3 rated

speed. Repeated 3 times each for

5 min. Blower fan blade shall not

damage, loose parts or deform.

2.1.4 Accelerated

aging test

2.1.5 Strap chemical

absorption test

<30%

2.1.6 Strap Drop Test There shall be no damage on load

bearing straps and their fixation

points that reduces their

functionality as a consequence of

the specified strap drop test.

Page 11: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

2.2 PERFORMANCE TEST

S. No. Item Particulars Unit Performance

specification

Test results Remarks

2.2.1

HO

RIZ

ON

TA

L M

IST

ING

Range m (declared by

the

manufacturer)

diagram in

annex

Width m (declared by

the

manufacturer)

Discharge rate

(average)

l/min (declared by

the

manufacturer)

Coefficient of

variation (CV)

% <6%

Residues

l <0.1

Droplet size

(VMD)

µm

Droplet density

droplets/cm2 if available

2.2.2

VE

RT

ICA

L

MIS

TIN

G

Deposition at 3m diagram in

annex

Discharge rate

(average)

l/min (declared by

the

manufacturer)

Coefficient of

variation (CV)

% <6%

2.2.3

HO

RIZ

ON

TA

L D

US

TIN

G

Range m (declared by

the

manufacturer)

diagram in

annex

Width m (declared by

the

manufacturer)

Discharge rate kg/min (declared by

the

manufacturer)

Deviation

% <15%

Idle discharge

g/min <40

2.2.4

VERTICA

L

DUSTING

Discharge rate kg/min (declared by

the

manufacturer)

Deviation % <5%

2.2.5 BLOWER

FAN

Air velocity

profile

diagram in

annex

Air flowrate m3/min

Page 12: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

2.3 SAFETY AND ENDURANCE

S.

No.

Item Particulars Unit Perform-

ance

specification

Test

result

Remarks

2.3.1 NOISE TEST dBA

2.3.2 VIBRATION TEST m/s2 ≤15

2.3.3 MTTFF

2.3.4 SAFETY LABELS

Firmly fitted /

informative

2.3.5 QUALITY OF

ASSEMBLY AND

APPEARANCE

1. All joints must

be firm reliable,

rotational parts

should be

flexible;easily

controlled;

rated power

shall be

obtained for the

maximum

position of the

throttle. At the

lowest position,

the engine shall

stop.

2. All parts shall

not be

deformed,

slanted, the

paint coat

quality should

meet with

quality standard

two and above.

2.3.6 EASE OF

OPERATION

1. Control devices

should be easy

and reliable

2. Easy

conversion

from mister to

duster

3. Easy

maintenance

4. Easy cleaning

Page 13: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

ANTAM TEST REPORT

3. Remarks and Suggestions

Signature of test engineer Signature of Head of Testing Station

Address: Address:

Date:

Official

Page 14: The Centre for Sustainable Agricultural Mechanization ... · S. No Units Conversion Factor 1 Force 1 kgf 9.80665 N 2.20462 lbf 2 Power 1 hp 1.01387 metric hp (ps) 745.7 W 1 ps 735.5

Recommended