17
BEV – Bundesamt für Eich- und Vermessungswesen Dissemination Meeting „Power & Energy“, Noordwijk M.Garcocz, BEV Austria The development and performance of high current shunts (> 20 A....100 A / 100 kHz) for power measurement
Transcript
Page 1: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Dissemination Meeting „Power & Energy“, Noordwijk M.Garcocz, BEV Austria

The development and performance of high current shunts(> 20 A....100 A / 100 kHz)

for power measurement

Page 2: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 2 of 14

Outline

Start April 2008: existing shunts for ac-dcexisting measurement methods

development of new measurement methods

BEV part:development of foil shunts for power measurement

mechanical modificationmeasurements

Page 3: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 3 of 14

April 2008: starting point

SP: Cage Design

ac-dc ~ - 50 µA/A

SP BEV

BEV: Foil Design

ac-dc ~ + 50 µA/A

Page 4: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 4 of 14

measurement capabilities:

existing:

BEV: ac-dcSP: ac-dc, dc, phase up to 1.500 Hz calculated from L and C

new developed measurement methods:

INRIM: phase angle errorCMI: TCR (temperature coefficiant of resistance)

PCR (power coefficient of resistance)

work in progress:SP: expanding L to pH and 100 kHz

PXI phase comparatorCMI: impedance

Page 5: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

ISTITUTONAZIONALEDI RICERCAMETROLOGICA 5

Phase comparator

A phase comparator was built for the measurements of phase differences between two shunts.

Basic circuit of the phase comparator. SH1 and SH2

denote the two shunts being compared. Two active

guarded transformers (AGTs) are employed as wideband

decoupled precision transmitters.

The current generator was assembled by

connecting a calibrator in the ac voltage

function that supplies a transconductace

amplifier.

Page 6: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

6Voltage source

Transconductanceamplifier

Oil bath with reference standard

oil bath temperaturecontrol

Dual channel DMM

Air box Air box temperature controlshunt

DC characterization of the shunts

• Method: measurement of ratio of output voltages of the tested and the reference standard by dual channel multimeter

• PC measured and calculated in current range of 50% - 100% of nominal current

• TC measured in temperature range from 18 °C up to 28(30) °C at 1/10 of nominal current

• Typical values for foil shunts:

PC < ± 4 ppm TC from -2.8 ppm to +8 ppm

Set up for TC measurement

E

E

X

XR

U

UR ⋅=

Page 7: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 7 of 14

motivation for new foil shunts

„Old design“

– very heavy units (28.5 kg for 100 A)

– long warmup time (~ 2 hours)

– dc properties not satisfying

– very time- consuming fabrication

„New design“

– reduced weight (2.9 kg for 100 A)

– warmup time ~ 10 min

– dc property?

Page 8: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 8 of 14

foil shunt - principle

OUTIN

Page 9: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 9 of 14

mechanical modification

currentIN

voltageOUTventilator

Page 10: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 10 of 14

temperature distribution forcerd air cooled foil shunts

54

56

58

60

62

0 1 2 3 4 5 6 7 8

Temperature distribution foil shuntfan position: centered

B50-1; 100 A

Position Pt 100

temp

[°C]

Page 11: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 11 of 14

EMRP Coaxial Foil Shunts

Page 12: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 12 of 14

coaxial foil shunts ac-dc values

-20.0

0.0

20.0

40.0

60.0

80.0

100.0

120.0

140.0

160.0

1 10 100

BZ1 30µ 42.28 mΩΩΩΩ nom. 16 A

BZ2 45µ 24.29 mΩΩΩΩ nom. 20 A

BZ3 30µ 8.64 mΩΩΩΩ nom. 100 A

BZ4 45 µ 5.28 mΩΩΩΩ nom. 100 A

BM1 23µ 15.20 mΩΩΩΩ nom. 50 A

BM2 70µ 5 mΩΩΩΩ nom. 100 A

BM3 70µ 5 mΩΩΩΩ nom. 100 A

EMRP foil shunts BEV

ac-d

c c

urr

en

t tr

an

sfe

r d

iffe

ren

ce

A/A

]

frequency [kHz]

Page 13: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 13 of 14

DC - Power Coefficient

-200

-150

-100

-50

0

50

0 10 20 30 40 50 60 70 80 90

BZ3

BZ4

BM1

BM2

BM3

B20-3

B40-2

B80-2

CMI measurements on BEV shunts

Power [W]

relative change of

dc- resistance

[µΩ/Ω]

all curves referenced to 1% nominal power

Power Coefficient Resistance

ZERANIN 30 µm

ZERANIN 45 µm

MANGANIN 70 µm

MANGANIN 23 µm

old design 23 µm

Page 14: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 14 of 14

DC - Temperature Coefficient 20...30°C

-60

-40

-20

0

20

40

60

80

100

17 20 23 26 29

B80-2

BZ3

BZ2

BZ4

BM1

BM2

BM3

B40-2

B50-1

B20-3

Temperature Coefficient Resistance

temperature [°C]

relative change of

dc- resistance

[µΩ/Ω]

ZERANIN 45 µm

ZERANIN 30 µm

MANGANIN 23 + 70 µm

MANGANIN 23 µm

TC with full power

CMI measurements on BEV shunts

all curves referenced to 18°C

meas. current = 1/10 of nominal

Page 15: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 15 of 14

Temperature Coefficient 20...70°C

-1600

-1400

-1200

-1000

-800

-600

-400

-200

0

200

20 25 30 35 40 45 50 55 60 65 70 75

MANGANIN 23µm

MANGANIN 70µm

ZERANIN 45µm

Temperature [°C]

change of resistance

relative to start

[µΩ/Ω]

startday 1 day 2

day 3

day 4

Page 16: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 16 of 14

thermal treatment

-3500

-3000

-2500

-2000

-1500

-1000

-500

0

500

20 30 40 50 60 70 80 90 100

Temperature [°C]

change of resistance

relative to start

[µΩ/Ω]

180 °C

MANGANIN 23µm

ZERANIN 45µm

MANGANIN 70µm

Page 17: The development and performance of high current shunts ...projects.npl.co.uk/power_energy/docs/1535 The... · BEV – Bundesamt für Eich- und Vermessungswesen Page 12 of 14 coaxial

BEV – Bundesamt für Eich- und Vermessungswesen

Page 17 of 14

cage design versus foil design (>20 A...100 A)

ac-dc dc phase

Cage Design

Foil Design

Measurements performed:BEV: ac-dc; some dc

CMI: dc temperature + power coefficient; impedance measurementsINRIM: phase angle error measurementsSP: ac-dc; inductance; phase