Kelt sistemas implantológicos | Catalog
BIONER | Espigolera 9 - 08960 Sant Just Desvern - BarcelonaTel: 93 470 03 60 | Fax: 93 470 35 27 | [email protected] | www.bioner.es
the futureis ourpresent
Contents
Cont
ents
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
€ € Price list
Implant overviewTypes and dimensionsDrill sequenceSurgical protocol
HE HE External hexagon components
CI CI Internal cone components
HI HI Internal hexagon components
Instruments
Introduction
TH
the futureis ourpresent
Introduction
Intr
oduc
tion
1© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
In 2006 Bioner introduced several improvements in its implant design, including a new surface developed un-
Bioner was established in 1992 and, in its early years, dedicated itself exclusively to the manufac-ture and sale of components compatible with all major implant systems. In 1998, already enjoying a strong position in the Spanish market, Bioner started the design, development and marketing of its own implant under the guidance of various uni-versities and renowned research centers.
In 2005, in order to increase the capacity and quality of its production process, Bioner acquired an industrial plant where the headquarters moved later on.
In recent years the company has continued to promote the expansion and improvement of products by incorporating cutting-edge machinery in order to continue to supply the Spanish market and start trading in the foreign market.
Bioner complies the guidelines contained in both ISO 9001 and 13485 and has both
ISO 13485 ISO 9001
Implant overview | Types and dimensions Drilling sequence | Surgical protocol
The chosen method to improve the implants surface is acid etching, discarding other methods that entail a greater contamination risk. Acid etching creates cavities and pores in the implant surface that enables a rapid bone growth through them, a phenomenon known as osteoconduction. Bioner implants enable osteointegration in a short period of time, also in early and immediate loading procedures.
PROFILOMETRY.Ra value of 0,72 µm
FATIGUE TEST. Fatigue limit ( 5x10 6 cycles) of 450N.
CYTOTOXICITY FOLLOWING ISO 10993 Standard. NO contamination found.
Before their commercial release, Bioner implants have un-dergone a series of tests in order to validate their proper performance. Some of the results obtained are:
A more complete dossier detailing the tests performed and the results obtained is available for those customers interested in further information.
Implant characteristics
IMP© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Impl
ant
char
acte
ristic
s
1
Implant types and dimensions
Impl
ant
type
s an
d di
men
sion
s
2IMP
P
2,7
0,7
L
DIKE
LT
P
2,7
0,7
L
D
BIK
ELT
IKELT BIKELT Suited for bone types III and IV
D.5P.5
D.4P.4,1
D.4,1P.4,1
D.3,75P.4,1
D.3,3P.4,1
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
D.5P.4
L. 18 IKELT418IKELT37518
L. 6 BIKELT5/46
L. 7 IKELT57IKELT47IKELT3757 BIKELT5/47
L. 8,5 IKELT585IKELT485 BIKELT485IKELT37585 BIKELT5/485
L. 10 IKELT510IKELT410 BIKELT410IKELT37510IKELT3310 BIKELT5/410
L. 11,5 IKELT5115IKELT4115 BIKELT4115IKELT375115IKELT33115 BIKELT5/4115
L. 13 IKELT513IKELT413 BIKELT413IKELT37513IKELT3313 BIKELT5/413
L. 15 IKELT515IKELT415 BIKELT415IKELT37515IKELT3315
Implant types and dimensions
Impl
ant
type
s an
d di
men
sion
s
3IMP© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
HIKELT
D
3,5
2,4
Dc
L
HIK
ELT
D.3,8Dc.3,95
HIKELT3885
HIKELT3810
HIKELT38115
HIKELT3813
HIKELT3815
D.4,7Dc.4,9
HIKELT4785
HIKELT4710
HIKELT47115
HIKELT4713
HIKELT4715
L. 7
L. 8,5
L. 10
L. 11,5
L. 13
L. 15
L. 18
Drilling sequence/ External hexagon implants
Dril
ling
sequ
ence
/ Ex
tern
al h
exag
on im
plan
ts
4IMP
IKELT BIKELT
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Ø3,3 Implant
Optional
Ø3,75 Implant
Optional Optional
Ø4 Implant
Optional
Ø4.1 ImplantF-LA
F-AV3/4 Ø4 | 500/800 RPM
F-AV5 Ø5 | 500/800 RPM
F-2C
F-2L
F-325C
F-325L
F-285C
F-285L
F-38L
F-3C
F-3L
F-4L
F-315C
F-315L
8.5 01011.5
131518
Ø2 | 800/1000 RPM
Ø2.85 | 800/1000 RPM
Ø3 | 500/800 RPM
Ø3.15 | 500/800 RPM
Ø3.25 | 500/800 RPM
Ø3.8 | 500/800 RPM
Ø4 | 500/800 RPM
Implante Ø5 Ø5 Implant
Optional Optional
Drilling sequence/ Internal hexagon implants
Dril
ling
sequ
ence
/ In
tern
al h
exag
on im
plan
ts
5IMP
HIKELT
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
F-LA
F-AV3/4 Ø4 | 500/800 RPM
F-AV5 Ø5 | 500/800 RPM
F-2C
F-2L
F-325C
F-325L
F-285C
F-285L
F-38L
F-3C
F-3L
F-4L
F-315C
F-315L
8.5 01011.5
131518
Ø2 | 800/1000 RPM
Ø2.85 | 800/1000 RPM
Ø3 | 500/800 RPM
Ø3.15 | 500/800 RPM
Ø3.25 | 500/800 RPM
Ø3.8 | 500/800 RPM
Ø4 | 500/800 RPM
Ø3.8 Implant Ø4.7 Implant
Optional
Optional
Surgical protocol
Surg
ical
pro
toco
l
6IMP© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Package opening
1
Remove the plastic tube from inside the box. The box contains the traceability la-bels as well.
Unscrew the colored cap , breaking the seal, and drop the inner container (which contains the implant) into the sterile
3
Remove the hexed cap from the cylinder. The implant is inside of the tube, pro-tected by a Titanium ring.
4
When needed, unscrew the superior part
Implant insertion
2
1
Remove the implant with the insertion tool.
2
Bring the implant towards the oral cav-ity. It is recommended to do it just as it
inverted.
3
Start the implant insertion in the bone bed with as low revolutions per minute as possible. Do not exceed an insertion Torque of 55 Ncm.
Once the implant is placed remove the insertion tool, shaking it slightly.
1 2
4
Surgical protocol
Surg
ical
pro
toco
l
7IMP© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
WARNING
1
Do not insert the tool into the implant while the handpiece is rotating. The im-plant connection may be damaged.
In case it is necessary to reinitiate the insertion process once it has already started, it is recommended to do it with a ratchet.
Cover screw placement
3
Place the cover screw over the implant.
!
2
HEExternal Hexagon Components
Healing abutments
X=2,3,4,5PC-x/D5
X=2,4PC-xWP
X=2,4PC-xNP
X=2,3,4,5,7PC-x
X=3,4,5PC-xA
Open tray impression copings
I-2NP I-2 I-2R I-2S I-2/D5 I-2WP
ø3,3NP ø3,3/ø3,75/ø4 ø5 ø5WP User guide
I-2B I-2C I-2D I-2B/D5
Closed tray impression copings
Hexed components. Non- hexed components.
Direct-to-implant external hexagonHealing abutments/ Impression copings
Hea
ling a
butm
ents
/ Im
pre
ssio
n c
opin
gs
Dire
ct-t
o-im
plan
t ex
tern
al h
exag
on
1HE© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Direct-to-implant external hexagonAnalogs | Castables
Anal
ogs
| C
asta
ble
s
Dire
ct-t
o-im
plan
t ex
tern
al h
exag
on
2HE
ø3,3NP ø3,3/ø3,75/ø4 ø5 ø5WP User guide
Castables
Analogs
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Metal base
C-2/D5 C-2WPC-2 CR-2
CR-1
C-2NP
C-1NP C-1 C-1/D5 C-1WP
A-2NP A-2 A-2/D5 A-2WP
Hexed components. Non- hexed components.
Direct-to-implant external hexagonTemporary abutments | Final abutments | Ball abutments
Tem
pora
ry a
butm
ents
| F
inal
ab
utm
ents
| B
all ab
utm
ents
Dire
ct-t
o-im
plan
t ex
tern
al h
exag
on
3HE© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø3,3/ø3,75/ø4 User guideø5
Hexed components. Non- hexed components.
Temporary abutments
MP-2 MPT-2MPT-1MP-1
Final abutments
MB-2 MB-1
MRA-2 MRA-1
MB-2/D5
MRA-2/D5
MB-1/D5
MRA-1/D5
MA-30
30º
MA-15
15º
MA-25
25º
Ball abutments
CTR-CCTR-xX=0,1,2,3
Direct-to-implant external hexagonCaps | Cap accessories | Screws
Cap
s | C
ap a
cces
sori
es | S
crew
s
Dire
ct-t
o-im
plan
t ex
tern
al h
exag
on
4HE
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø3,3NP ø3,3 /ø3,75/ø4 / ø5 ø5WP
Screws
T-2ANP T-2AWP
Caps Cap accessories
CiCH CiC
ø3,3/ø3,75/ø4
Hexed components. Non-hexed componets.
CiE C.CiC T-2TL T-2TC
T-2AT-1CT-1A T-2
T-2C T-2U T-2E
T-2A/1.3
User guide
T-2AT
Anti-loosening
External hexagon CTM conical abutmentTapered abutments | Healing cap | Impression copings | Analog | Castable
Tap
ered
abutm
ents
| H
ealing c
ap | I
mpre
ssio
n c
opin
gs
| A
nal
og | C
asta
ble
Exte
rnal
hex
agon
CTM
con
ical
abu
tmen
t
5HE© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø3,3/ø3.75/ø4
Hexed components. Non- hexed components.
Analog
A-5M
Castable
C-5LM
Healing cap
TC-5M
Impression copings
I-5M I-5BM
Tapered abutments
CTM-xx=1,2,3,4,5,6,7,8,9
CTM-x17x=2,3
CTM-x30x=3,4
External hexagon CTM conical abutmentTemporary abutments | Caps | Cap accessories | Screws
Tem
pora
ry a
butm
ents
| C
aps
| Ca
p ac
cess
orie
s |
Scre
ws
Exte
rnal
hex
agon
CTM
con
ical
abu
tmen
t
6HE
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø3,3/ø3.75/ø4
Cap accessories
CCiCM T-2TMC T-2TML
Screws
T-3AM T-3UM T-3M T-4M
Caps
CiCMCiEM
Temporary abutments
MPT-M
+
Hexed components. Non- hexed components.
HIInternal hexagon components
Direct-to-implant internal hexagonHealing abutments | Impression copings | Analogs | Castables
Hea
ling a
butm
ents
| I
mpre
ssio
n c
opin
gs
| A
nal
ogs
| C
asta
ble
s
Dire
ct-t
o-im
plan
t in
tern
al h
exag
on
1HI
Impression copingsCubeta cerrada Cubeta abierta
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.esHexed components. Non- hexed components.
Analogs
A-200 A-200/D45
Healing abutments
PC-21x PC-21x/D45X=2,4X=2,3,4,5
I-205 I-200
ø3,5 ø4,5 User guide ø3,5 ø4,5 User guide
Castables
C-202 C-202/D45
C-201 C-201/D45
Metal base
CR-202
CR-201
Direct-to-implant internal hexagonTemporary abutments | Final abutments | Ball abutments | Caps | Cap accessories | Screws
Tem
pora
ry a
butm
ents
| F
inal
abu
tmen
ts | B
all ab
utm
ents
| C
aps
| C
ap a
cces
sori
es | S
crew
s
Dire
ct-t
o-im
plan
t in
tern
al h
exag
on
2HI
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
User guide
Final abutments
MTC-200
Hexed components.. Non- hexed components
ø3,5 /ø4,5
Angled abutmentsAngled from the vertex
MA-250V
Angled from the side
MA-250C
Caps
CiHC CiHE
Screws
T-201 T-201ET-202 T-100
Anti-loosening
Temporary abutments
MPT-201 MPT-201/D45MPT-202 MPT-202/D45
T-2TL13 T-2TC13
Cap accessories
C.CiC
Ball abutments
CTR-CCTR-x00X=0,1,2,3
Internal hexagon abutmentTapered abutments | conical abutments | Analog/Castable | Impression coping | screw
Tape
red
abut
men
ts |
con
ical
abu
tmen
ts |
Ana
log/
Cast
able
| I
mpr
essi
on c
opin
g |
scre
w
Inte
rnal
hex
agon
abu
tmen
t
3HI
ø3,5 User guide ø3,5 User guide
Tapered abutments Analog
ø4,5
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
CTC-21xX=1,2,3,4,5,6,7
Conical abutments
CTCM-xX=1,2,3
CTCM-x/D45X=1,2,3
Screw
T-204
Impression coping
I-206
A-210
Castable
C-207
Hexed components. Non- hexed components.
Angled conical abutmentsAngled from the side
X=2,3 X=3,4
Angled from the vertex
X=2,3 X=3,4CTCM-x17V CTCM-x30V CTCM-x17C CTCM-x30C
CIInternal cone components
Direct-to-implant internal coneHealing abutments | Analog | Castables | Impression coping | Abutments | Caps | Cap accessories | Screw
Hea
ling a
butm
ents
| A
nal
og | C
asta
ble
s | Im
pre
ssio
n c
opin
g | A
butm
ents
| C
aps
| C
ap a
cces
sori
es | S
crew
Dire
ct-t
o-im
plan
t in
tern
al c
one
1CI© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø4,8
Hexed components. Non- hexed components.
Caps
CI-CiCZR CI-CiCZ
Cap accessories
CI-CCiC
Screw
CI-TxCZ
Healing abutments
CI-PCxX=2,3
Abutments
CI-MPT CI-MPT2CI-MxX=4,5.5,7
Castables
CI-C1 CI-C2
Metal base
CI-CR2CI-A
Analog
CI-I2
Impression coping
Internal cone abutmentAbutments | Castables | Temporary abutments
Abutm
ents
| C
asta
ble
s | T
empora
ry a
butm
ents
Inte
rnal
con
e ab
utm
ent
2CI
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø4,8
Hexed components. Non- hexed components.
Abutments
Temporary abutmentsCastables
CI-C CI-CSyn
CI-CP17
CI-P CI-PSyn CI-PSynC
CI-P17A CI-P17B
CI-MPTO CI-MPTO2
Internal cone abutmentCaps | Cap accesories | screws
Cap
s | C
ap a
cces
ori
es | s
crew
s
Inte
rnal
con
e ab
utm
ent
3© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
ø4,8
Screw
Hexed components. Non- hexed components.
Cap accessories
Caps
CI-CiC CI-CiE
CI-CCiC
CI-Tx
Drivers and insertion tools
Driv
ers
and
inse
rtio
n to
ols
1HER
DCA-13CDCA-13MDCA-13L
*U=7 MM
*U=12 MM
*U=20 MM
DCA-12CDCA-12MDCA-12L
*U=7 MM
*U=12 MM
*U=20 MM
DCA-UCDCA-UMDCA-UL
*U=7 MM
*U=12 MM
*U=20 MM
DCA-RUMDCA-RUL
*U=12 MM
*U=20 MM
Handpiece
PHC-13PHM-13PHL-13
*U=8 MM
*U=14 MM
*U=25 MM
PHC-12PHM-12PHL-12
*U=8 MM
*U=14 MM
*U=25 MM
PUCPUMPUL
*U=8 MM
*U=14 MM
*U=25 MM
PRUMPRUL
*U=14 MM
*U=25 MM
LDR wrench
DCH-13DMH-13DLH-13
*U=8 MM
*U=14 MM
*U=25 MM
DCH-12DMH-12DLH-12
*U=8 MM
*U=14 MM
*U=25 MM
DUCDUMDUL
*U=8 MM
*U=14 MM
*U=25 MM
DRUMDRUL
*U=14 MM
*U=25 MM
Manual
CHC-13CHM-13CHL-13
*U=8 MM
*U=14 MM
*U=25 MM
CHC-12CHM-12CHL-12
*U=8 MM
*U=14 MM
*U=25 MM
CUCCUMCUL
*U=8 MM
*U=14 MM
*U=25 MM
CRUMCRUL
*U=14 MM
*U=25 MM
LCC ratchet
HEX 1.3 HEX 1.2 GRIP GRIP angled
*U= Usable length
*U
DXL-13 *U=25 MM DXL-12 *U=25 MM DXLU *U=25 MM
Extra-large47 mm. shaft
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
DCA-SCDCA-SMDCA-SL
*U=9 MM
*U=13 MM
*U=21 MM
PSMPSL
*U=14 MM
*U=21 MM
DSMDSL
*U=14 MM
*U=21 MM
CSMCSL
*U=14 MM
*U=21 MM
IKELTinsertion tool
DCA-SiC DCA-SiL
*U=8 MM
*U=17 MM
PSiMPSiL
*U=11 MM
*U=18 MM
DSiMDSiL
*U=11 MM
*U=18 MM
CSiMCSiL
*U=14 MM
*U=19 MM
HIKELT insertion tool
Drivers and insertion tools
Driv
ers
and
inse
rtio
n to
ols
2HER
LCCLDR
LDR - LCC Adapter
DCA-PL *U=12 MM DCA-C *U=12 MM DCA-TT *U=11 MM
DCA-TxCDCA-TxMDCA-TxL
*U=7 MM
*U=12 MM
*U=20 MM
Handpiece
PMP *U=14 MM PMC *U=14 MM PCTT *U=14 MM
PTxCPTxMPTxL
*U=8 MM
*U=14 MM
*U=25 MM
LDR wrench
DLP *U=14 MM DLC *U=14 MM DCH-18 *U=9 MM DCTT *U=14 MM
DTxCDTxMDTxL
*U=8 MM
*U=14 MM
*U=25 MM
Manual
CTxCCTxMCTxL
*U=8 MM
*U=14 MM
*U=25 MM
LCC ratchet
Slot Squared HEX 1.8 TUBULARStar
*U= Usable length
*U
DXP *U=25 MM DXC *U=25 MMDXLTx *U=25 MM
Extra-large47 mm. shaft
© BIONER. Espigolera 9 - 08960 Sant Just Desvern - Barcelona | Tel. 93 470 03 60 - Fax. 93 470 35 27 | [email protected] | www.bioner.es
Brochure design: Bernat Sarrias | [email protected] 2012-1-1