Page 1: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02
Page 2: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

The Northwestern University Atomic and Nanoscale Characterization Experimental Center (NUANCE) was established during 2001-02 to integrate complementary analytical instruments and characterization capabilities at Northwestern University. NUANCE serves NU and the broader scientific and engineering community, and provides invaluable resources to the private sector and public institutions in and around the Midwest. An operationally and fiscally efficient solution to the increasing need for advanced analytical and characterization instrumentation, NUANCE leverages staff technical expertise to assist and collaborate with researchers in the physical sciences, engineering, and interdisciplinary fields. NUANCE integrates three complementary instrumentation facilities: EPIC, Keck-II, and SPID under a unified management umbrella. These three facilities are a unique, centralized and comprehensive resource for the NU community and beyond. NUANCE retains the individual identity of the three facilities, but their integration with unified operations promotes synergy among instruments, staff, training, service, technical expertise and new cross-disciplinary initiatives. Our mission is to provide and continually update state-of-the-art and core analytical characterization instrumentation resources, with 24/7 open access, for the NU community and beyond. The word “resource” includes not only mere “instrumentation and access,” but also hands-on training, education, research collaboration and outreach. NUANCE aspires to be a pro-active and integral part of all scholarly activities related to characterization at and beyond NU.

Page 3: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

NUANCE actively participates in societal and global outreach, innovative course and curricula development, and hands on laboratory access for students, researchers, staff and faculty. NUANCE serves as an anchor for NU global programs and contributes to international collaborations through the exchange of researchers and students. NUANCE is renowned for developing a well-trained and globally informed workforce in interdisciplinary science and technology. Local teachers, museums, and members of the community are encouraged to join NUANCE through open house visits, demonstrations, and online.

EPIC: Electron Probe Instrumentation Center

Keck-II: Keck Interdisciplinary Surface Science Center

SPID: Scanned Probe Imaging and Development Facility

Page 4: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

Formed under the NU Materials Research Center (MRC), the Electron Probe Instrumentation Center (EPIC) houses an array of scanning, transmission and scanning transmission electron microscopes (SEM, TEM and STEM), a comprehensive specimen preparation facility, and a BioCryo Facility for imaging and analysis of biological and soft samples.

High Pressure Freezer HPM100 (Leica)

Hitachi HT-7700 S/TEM

FEI Vitrobot Plunge Freezer

Hitachi HD-2300 Dual EDS Cryo STEM

Leica UC7/FC7 Cryo-Ultramicrotome

Hitachi H-8100 TEM

Leica EM ACE 600

JEOL JEM-2100F FasTEM

EPIC BIOCRYO, TEM & STEM CAPABILITIES • SE-, TE-, and Z-Contrast Imaging • Electron Diffraction • Energy Dispersive X-Ray Spectroscopy (EDS) • Electron Energy Loss Spectroscopy (EELS) • Bright-Field and Dark-Field Imaging • High Resolution Electron Microscopy (HREM) • Scanning Transmission Electron Microscopy

(STEM) with Annular Bright-Field, Dark-Field, and High-Angle Annular Dark-Field Detectors

• Selected Area Electron Diffraction (SAED) • Convergent Beam Electron Diffraction (CBED)

• Simultaneous SEM and STEM Imaging at 200keV

• TEM and STEM Electron Tomography • Cryo (Liquid Nitrogen) S/TEM Imaging • In Situ Heating, Fluid-Flow, and Electric

Biasing TEM/STEM • Gatan Image Filter (GIF) System • Energy Filtered Transmission Electron

Microscopy (EFTEM) • Nano Beam Diffraction and Convergent

Beam Electron Diffraction (CBED) • And More…

Page 5: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

Hitachi S3400N-II SEM Hitachi S4800-II cFEG SEM

Hitachi SU8030 cFEG SEM

LEO Gemini 1525 SEM

FEI Quanta 600F ESEM

FEI Helios Nanolab 600 Dual Beam

EPIC SEM CAPABILITIES EPIC SAMPLE PREPARATION CAPABILITIES • X-Ray Microanalysis (EDS) • Electron Backscatter Diffraction (EBSD) • Cathodoluminescence (CL) • Electron Beam Lithography • Ion Beam Nanofabrication • Environmental SEM (ESEM) • Focused Ion Beam (FIB) Tomography • Ultra-High Resolution Imaging • In Situ Nanomanipulation and Probing • SE and BSE Imaging • STEM Imaging • Cryo SEM Imaging • Site-Specific Sample Preparation • And More…

• Precise Cutting, Grinding and Polishing • Chemical Etching • Ion Beam Thinning • Spin, Sputter, and Os Coating • Metal and Carbon Evaporation • High-Pressure Freezing • Critical Point and Freeze Drying • Cryo Plunging and Transfer System • Plasma and UV Cleaning • Resin Embedding • Cryo Ultramicrotomy • And More…

Page 6: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

Keck-II was established through the support of the W. M. Keck Foundation. It houses state-of-the-art surface analysis and related instrumentation.

High Resolution Stylus Profilometer

3D Optical Microscope

Spectroscopic Ellipsometer

Confocal Raman Spectroscopy

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS)

Fourier Transform Infrared (FT-IR) Spectroscopy

X-ray Photoelectron Spectroscopy (XPS/ESCA)

Zetasizer

KECK-II CAPABILITIES

• High Resolution XPS • XPS Imaging • UPS • Depth Profiling

• ToF-SIMS Spectroscopy, Mapping, Depth Profiling

• FT-IR • ATR • PM-IRRAS • Surface Profiling • Spectroscopic Ellipsometry • Confocal Raman Spectroscopy • Photoluminescence • Zeta Potential and Particle Size • And More…

Page 7: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

The Scanned Probe Imaging and Development (SPID) Facility was established under the leadership of the International Institute for Nanotechnology (IIN), primarily through funding support from the State of Illinois. SPID provides state-of-the-art soft lithographic patterning, atomic and molecular quantitative imaging and analysis capabilities.

HORIBA LabRAM HR Evolution Confocal RAMAN System

Bruker BioScope Catalyst

Hysitron 950 Triboindenter

Bruker Dimension ICON PT System

Bruker Dimension FastScan AFM

SPID CAPABILITIES • Scanning Kelvin Probe Microscopy • Fluorescent and Collection Mode Imaging • Multiplexed Biomaterials Nanopatterining • Low and High Temperature Capabilities • Dynamic Modulus and Quantitative Current

Mapping • Fastscan and Electrochemical AFM • Peak Fore TUNA and Conducting AFM • Nanoman

• Aqueous Ambient, Viscoelastic, Quantitative Nanomechnical, Life Science, Phase Contrast, Piezoresponse, and Brightfield and Darkfield Imaging

• Combined Optical, Fluorescent and AFM Imaging

• Scratch Testing • Nano-Indentation of Soft and Hard Materials • High Speed Imaging • And More…

Page 8: The Northwestern University tomic and · 2019. 8. 22. · The Northwestern University tomic and Aanoscale N Characterization Experimental Center (NUANCE) was established during 2001-02

Technical Inquiries:

Prof. Vinayak P. Dravid Director, NUANCE Center

[email protected] 847.467.1363

Financial Operations: Outreach and Education: Chad Goeser Raymond Bailey Financial Administrator, NUANCE Center Outreach Coordinator, NUANCE Center [email protected] [email protected] 847.467.2318 847.467.3144

www.nuance.northwestern.edu