18
Hamburg University of Technology The Oxyfuel Process with Circulating Fluidised Bed Combustion and Cryogenic Oxygen Supply September 13 th 2013 – 3 rd Oxyfuel Combustion Conference C. Günther M. Weng A. Kather Institute of Energy Systems
Transcript
Page 1: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of Technology

The Oxyfuel Process with Circulating Fluidised Bed Combustion and Cryogenic Oxygen Supply

September 13th 2013 – 3rd Oxyfuel Combustion Conference

C. Günther

M. Weng

A. Kather

Institute of Energy Systems

Page 2: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

• Huge bandwidth of possible fuels

• Emission reduction by primary measures

▸ Low combustor temperatures and air staging reduce significantly the amount of NOx produced during combustion

▸ SO2-emissions can be reduced by in-situ desulphurisation

• Oxyfuel Next to the flue gas the circulated solids can be used as a heat sink for the process (in contrast to pulverised coal firing)

Potential to reduce the amount of flue gas recirculated

Advantages of Circulating Fluidised Bed Boilers

2

Page 3: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Available Heat Sinks for Oxyfuel Processes

PC:

CFBC:

TO2

TFG-Recirculation

Tadiabat

TCoal Q

TO2

TFG-Recirculation

TCC

TCoal CHEQCCQ

EHEQTSolids-

Recirculation

2/3

1/3

?

?

CC – Combustion ChamberEHE – External Heat Exchanger CHE – Convective Heat

Exchanger

3

Page 4: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

• Link of EBSILON and ASPEN via ProgDLL allows the simultaneous execution of both software applications

Input CO2 Processing Unit• Composition

• FlowOverall Process CO2 Processing Unit

Process Evaluation• Transferred heat quantities

• Gas compositions• Efficiencies

• etc.

Input Overall Process• Power requirements

• Cooling demand• Steam demand

• CO2 purity

Software and Simulation

4

Page 5: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Process Scheme

Air

Vent gas

Air Separation Unit (ASU)

N2

O2

FuelInerts

FG-Recirculation

H2O

FG-Drying

CO2-Liquefaction

Nearly pure CO2

Ash

FG-Recirculation

Goal

Identification of main influencing variables on feasibility and efficiency of the process under realistic boundary conditions

5

Page 6: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

• State-of-the-art power plant with EHE (460 MWel,gross – about 1000 MWth)

• South American hard coal (El Cerrejón – Burnout 99 %)

• CC-outlet: 880 °C

• EHE-outlet: 550 °C

• Steam parameters: 275 bar / 54 bar; 560 °C / 580 °C (SH/RH)

• Feed water temperature: 290 °C ; FG outlet temperature (CHE) 340 °C

• Temperature of recirculation (beneficial as hot as possible, limited by available fans)

▸ To CC: about 340 °C; To EHE: about 150 °C (preheated to 290 °C)

• Oxygen ratio 1.15 - Oxygen purity 95 volume-%- 2 % air ingress at the convective heat exchangers- 0.5 % air ingress at the electrostatic precipitator

Basic Assumptions I

6

Page 7: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

CC- Cross Sectional Area

▸ Reduction of the FG-Recirculation leads to a smaller cross sectional area of the CC and the CHE (u0=const.)

▸ Same effect for higher velocities leading to:

▸ Less available space for heat transferring areas walls and additional equipment in the combustor (e.g. wing walls)

▸ Differences to Lagisza depend on simulated coal and u0

30 40 50 60 7050

100

150

200

250

300 4 m/s5 m/s6 m/s

Cros

s Se

ctio

nal A

rea

of th

e CC

in m

²

FG - Recirculation in %

Area of Lagisza (27,6 m x 10,6 m)

7

Page 8: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Air Case

▸ About 32,5 % of the heat are transferred in the CHE

▸ Approximately 28,5 % are transferred in the CC (wing-walls with ribbed tubes and platen superheater)

▸ Remaining heat is transferred in the EHE (39 %)

Oxyfuel Air

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

8

Page 9: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

Oxyfuel – Convective Heat Exchanger (CHE)

▸ Temperatures:TCHE, in = 880 °C, TCHE, out = 340 °C

▸With a decreasingFG-recirculation there is less massflow through the CHE

▸ Leading to less heat transferred in the CHE

Oxyfuel Air

9

Page 10: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Oxyfuel – Combustion Chamber (CC) II

▸ A decrease in the FG-Recirculation leads to a smaller cross-sectional area (u0=const.)

▸ Reduction of heat transferring area (wall and equipment)

▸ Less heat can be withdrawn out of the CC

▸More heat has to be transferred in the EHE

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

Oxyfuel Air

10

Page 11: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Oxyfuel – External Heat Exchanger (EHE) I

▸ The amount of heat transferred in the EHE increases with a reduction of the FG-Recirculation

▸ The theoretical minimum of FG-Recirculation is about 35 %

▸ The whole recycled FG is necessary to fluidise the EHE

▸ CC O2-Conc.in the CC nozzle floor exceeds limits hot-spots in the bed

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

Oxyfuel Air

Min

imum

Flu

idis

atio

nof

EHE

11

Page 12: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Oxyfuel – External Heat Exchanger (EHE) II

▸ The restricting limit for the range of operation of the Oxyfuel-CFB is the state-of-the-art of the EHE

▸Geometrical arrangement around the boiler is limited

▸ Design of Loop-Seal and EHE

▸Minimum for the FG-Recirculation > 60 %

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

Oxyfuel Air

Min

imum

Flu

idis

atio

nof

EHE

Geo

met

rie a

ndD

esig

n

12

Page 13: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

Oxyfuel – External Heat Exchanger (EHE) III

▸Minimum for the FG-Recirculation ≈ 60 %

▸ Changes in the transferred heat due to Oxyfuel conditions:

▸ CHE ≈ 25 % (- 7,5 %-pt.)

▸ CC≈ 22 % (- 6,5 %-pt.)

▸ EHE≈ 53 % (+14 %-pt.) + 1/3

30 40 50 60 700

102030405060708090

100

CHE

CC

Tran

sfer

red

Heat

Qua

ntitie

s in

%

FG - Recirculation in %

EHE

Oxyfuel Air

Min

imum

Flu

idis

atio

nof

EHE

Geo

met

rie a

ndD

esig

n

13

Page 14: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

30 40 50 60 700

102030405060708090

100

Volu

met

ric G

as C

once

ntra

tions

at t

he

Entra

nce

of th

e G

PU in

vol

.-% (d

ry)

FG - Recirculation in %

0102030405060708090100

O2 C

once

ntra

tion

at th

e No

zzle

Flo

or

of th

e CC

in v

ol.-%

(dry

)

Oxyfuel – Selected Flue Gas Concentrations

▸ Due to air ingress there is a maximum for the CO2 concentration of 80 %

▸ For lower recycle rates the CO2 concentration decreases due to an increase in residual oxygen

▸ The O2 concentration in the flue gas increases accordingly

▸ The O2 concentration at the CC nozzle floor in-creases for decreasing FG-Recirculation

CO2

O2

14

Page 15: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

• Assumptions

▸ Live steam parameter: 275 bar, 560 °C

▸ Reheat: 54 bar, 580 °C

▸ Condenser pressure: 45 mbar

▸ ASU: 236 kWh/tO2,pure (adiabatic compression)

• Calculated efficiencies for comparisons

Air Case PC: ηel,net ≈ 44.2 %

Air Case CFBC: ηel,net ≈ 43.3 %

Oxy-PC: ηel,net ≈ 34,1-35,0 %

Oxy-CFBC: ηel,net ≈ 34,1 % - 34,4 %

Oxyfuel – Efficiencies I

Δη = 0,9 %-pts.

Δη = 0 - 0,6 %-pts.

15

Page 16: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

30 40 50 60 7047,5

48,0

48,5

49,0

49,5

50,0

Elec

tric

Gro

ss E

fficie

ncy

in %

FG - Recirculation in %

33,0

33,5

34,0

34,5

35,0

35,5

Elec

tric

Net E

fficie

ncy

in %

Oxyfuel – Efficiencies II

▸ For the chosen design the efficiency is at34,4 % and by this comparable to PC-firing

▸ Slight demand increase for ASU and GPU

▸ The loss for higher recirculation is due to CC-Compressor

▸ The electrical demand for the EHE fan is dominated by the CC-compressor for higher FG-Recirculation

16

Page 17: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

• The efficiencies of the CFBC are comparable to those of pulverised coal combustion, as long as no secondary flue gas treatment is necessary

▸ Efficiency loss in the order of 8 to 10 %-pts

• Primary goal Reduction of FG-Recirculation seems realisable, but is limited by:

▸ The fluidisation of the CC and EHE,

▸ Arrangement of the boiler,

▸ Design of Loop-Seal and EHE,

▸ The solids entrainment

Summary

17

Page 18: The Oxyfuel Process with Circulating Fluidised Bed ...

Hamburg University of TechnologyInstitute of Energy Systems

The Project

COORETEC-Cooperative Project: ADECOS ZWSF„Oxyfuel-Process with Circulating Fluidised Bed Boiler“

Duration: 1st January 2010 - 31st March 2013

Institutes: IET TU Hamburg HarburgIFK Universität StuttgartVWS TU Dresden

Industry Partners: EnBW Kraftwerke AGE.ON Energie AGRWE Power AGVattenfall Europe Generation AG & Co. KGLinde AGDoosan-Lentjes

Thank you for yourattention!!

18


Recommended