2
There is more to Ducted Reverse Cycle Air Conditioning than just the unit itself! A basic ducted unit is installed with duct and outlets to all spaces requiring heating or cooling. The temperature will be regulated by the single temperature gauge in one spot in the building, usually the Kitchen or Hall. This doesn’t take into account variables like: (1) Rooms with a lot of glass may be hotter than rooms with small windows (2) Rooms getting afternoon sun will be hotter than rooms on the shady side of the house. However, any house, office or other space consisting of various rooms can, for the sake of Air Conditioning Efficiency, be divided into sections or zones each controlled by a damper(s) to regulate air flow to better manage the temperature level. These could be: 1. Day & Night Zones 2. Separate Usage Zones (Kitchen & Lounge/ Kitchen & Bedrooms/ Kitchen & Dining/Games) 3. Specific Work Usage (Offices/Boardroom) The air conditioned space can then be selectively regulated via the dampers so that only the spaces in use have airflow. For example: 1. When there is little need to heat or cool bedrooms that are not in use during the day 2. An office boardroom doesn’t need continuous airflow when it may only be used once a week. By confining air flow to the spaces being occupied the A/C unit is allowed to work more efficiently and, because the whole volume of air is going into a smaller area, desired temperatures are reached quicker and maintained more easily. The use of this principle can result in real savings. For Example: If a large house is calculated to need a 20 Kilowatt Unit to effectively heat & cool the entire structure but further examination shows that, at any given time, only two thirds of the rooms/space are in use. With well designed zoning it is possible for the house to be satisfactorily serviced by a much smaller unit, providing a major up-front cost saving and ongoing power saving through the life of the unit. How well each zone can be regulated depends on the sophistication of the Damper control system being used. It could be: 1. A simple manual open/close system 2. A timer controlled open/close system 3. A more intuitive temperature sensitive variable flow system that reacts to the actual temperature in each room and/or timer controls. Air Conditioning Zone Management Systems The Principles of Zone Management for Efficient Ducted Air Conditioning Use Distributed by: ©2004 Polyaire™ Pty Ltd. The manufacturer reserves the right to alter product specifications without notice. E. & O.E. Conditions Apply. PBN_ZONE_01 The Zonemaster range is manufactured under licence from Polyaire, one of Australia’s largest and most established air conditioning fittings and components manufacturers, with over 30 years experience in the business. Polyaire’s head office is based in Adelaide, South Australia (Along with it’s major manufacturing plant) so you can specify Zonemaster or any other Polyaire brand with the confidence that you are dealing with an Australian based company that will work hard to ensure your satisfaction with our products. For our customer’s convenience Polyaire has 14 branches located across Australia. ACT Unit 21/1 Pirie St FYSHWICK ACT Ph: (02) 6126 3600 Fax: (02) 6228 1338 Victoria Unit 2/4 Monterey Rd DANDENONG VIC Ph: (03) 8710 7000 Fax: (03) 9769 2799 108-110 Northgate Drv THOMASTOWN VIC Ph: (03) 9465 8022 Fax: (03) 9465 5484 Western Australia 1 Booth Place BALCATTA WA Ph: (08) 6241 0555 Fax: (08) 9240 1484 United Kingdom Unit 17 Enterprise Court Park Farm Industrial Estate Wellingborough Northants ENGLAND NN8 6UW Ph: (44) 1933 402 666 Fax: (44) 1933 402 777 Asia 102, Jalan Dua, Kawasan Perindustrian Olak Lempit 42700 Banting, Selangor WEST MALAYSIA Ph: +603 3149 4100 Fax: +603 3149 4101 Internet www.polyaire.com.au HEAD OFFICE 11-13 White Rd GEPPS CROSS SA Ph: (08) 8349 8466 Fax: (08) 8349 8446 SALES OFFICES New South Wales Unit 1/167 Prospect Hwy SEVEN HILLS NSW Ph: (02) 8811 1333 Fax: (02) 9620 8088 Unit 2/6 Church Rd MOOREBANK NSW Ph: (02) 9600 8799 Fax: (02) 9600 8115 Unit 10/33 Maddox St ALEXANDRIA NSW Ph: (02) 9557 6948 Fax: (02) 9557 6954 70 Mitchell Rd CARDIFF NSW Ph: (02) 4954 6677 Fax: (02) 4954 6033 299 Copland St WAGGA WAGGA NSW Ph: (02) 6921 7606 Fax: (02) 6921 1987 4 Young St DUBBO NSW Ph: (02) 6884 4328 Fax: (02) 6884 4362 Queensland 81-89 Northlink Place VIRGINIA QLD Ph: (07) 3256 8958 Fax: (07) 3256 8718 14 Leda Drv ANDREWS QLD Ph: (07) 5576 8955 Fax: (07) 5576 8975 South Australia 5 O’Connor Crt GEPPS CROSS SA Ph: (08) 8349 5959 Fax: (08) 8349 6659 The Zonemaster range caters for basic needs, through to sophisticated temperature sensitive models with programming ability. Improving the efficiency of your Ducted Air Conditioning System
Transcript
Page 1: The Principles of Zone Management for Efficient …ascentair.com.au/pdf/polyaireVAVtempcontrolzoning.pdf · Polyaire’s head office is based in Adelaide, South Australia (Along with

There is more to Ducted Reverse Cycle Air Conditioning than just the unit itself!

A basic ducted unit is installed with duct and outlets to all spaces requiring heating or cooling. The temperature will be regulated by the single temperature gauge in one spot in the building, usually the Kitchen or Hall. This doesn’t take into account variables like:

(1) Rooms with a lot of glass may be hotter than rooms with small windows

(2) Rooms getting afternoon sun will be hotter than rooms on the shady side of the house.

However, any house, office or other space consisting of various rooms can, for the sake of Air Conditioning Efficiency, be divided into sections or zones each controlled by a damper(s) to regulate air flow to better manage the temperature level. These could be:

1. Day & Night Zones

2. Separate Usage Zones (Kitchen & Lounge/ Kitchen & Bedrooms/ Kitchen & Dining/Games)

3. Specific Work Usage (Offices/Boardroom)

The air conditioned space can then be selectively regulated via the dampers so that only the spaces in use have airflow.For example:

1. When there is little need to heat or cool bedrooms that are not in use during the day

2. An office boardroom doesn’t need continuous airflow when it may only be used once a week.

By confining air flow to the spaces being occupied the A/C unit is allowed to work more efficiently and, because the whole volume of air is going into a smaller area, desired temperatures are reached quicker and maintained more easily.

The use of this principle can result in real savings.

For Example: If a large house is calculated to need a 20 Kilowatt Unit to effectively heat & cool the entire structure but further examination shows that, at any given time, only two thirds of the rooms/space are in use. With well designed zoning it is possible for the house to be satisfactorily serviced by a much smaller unit, providing a major up-front cost saving and ongoing power saving through the life of the unit.

How well each zone can be regulated depends on the sophistication of the Damper control system being used.It could be:

1. A simple manual open/close system

2. A timer controlled open/close system

3. A more intuitive temperature sensitive variable flow system that reacts to the actual temperature in each room and/or timer controls.

Air Conditioning Zone Management Systems

The Principles of Zone Management for Efficient Ducted Air Conditioning Use

Distributed by:

©2004 Polyaire™ Pty Ltd. The manufacturer reserves the right to alter product specifications without notice. E. & O.E. Conditions Apply. PBN_ZONE_01

The Zonemaster range is manufactured under licence from Polyaire, one of Australia’s largest and most

established air conditioning fittings and components manufacturers, with over 30 years experience in the

business. Polyaire’s head office is based in Adelaide, South Australia (Along with it’s major manufacturing

plant) so you can specify Zonemaster or any other Polyaire brand with the confidence that you are dealing

with an Australian based company that will work hard to ensure your satisfaction with our products.

For our customer’s convenience Polyaire has 14 branches located across Australia.

ACT Unit 21/1 Pirie StFYSHWICK ACT

Ph: (02) 6126 3600Fax: (02) 6228 1338

Victoria Unit 2/4 Monterey RdDANDENONG VIC

Ph: (03) 8710 7000Fax: (03) 9769 2799

108-110 Northgate DrvTHOMASTOWN VIC

Ph: (03) 9465 8022Fax: (03) 9465 5484

Western Australia 1 Booth PlaceBALCATTA WA

Ph: (08) 6241 0555Fax: (08) 9240 1484

United Kingdom Unit 17 Enterprise Court Park Farm Industrial EstateWellingborough NorthantsENGLAND NN8 6UW

Ph: (44) 1933 402 666Fax: (44) 1933 402 777

Asia 102, Jalan Dua, Kawasan Perindustrian Olak Lempit42700 Banting, SelangorWEST MALAYSIA

Ph: +603 3149 4100Fax: +603 3149 4101

Internet www.polyaire.com.au

HEAD OFFICE 11-13 White Rd GEPPS CROSS SA

Ph: (08) 8349 8466Fax: (08) 8349 8446

SALES OFFICES

New South Wales Unit 1/167 Prospect HwySEVEN HILLS NSW

Ph: (02) 8811 1333Fax: (02) 9620 8088

Unit 2/6 Church RdMOOREBANK NSW

Ph: (02) 9600 8799Fax: (02) 9600 8115

Unit 10/33 Maddox StALEXANDRIA NSW

Ph: (02) 9557 6948Fax: (02) 9557 6954

70 Mitchell RdCARDIFF NSW

Ph: (02) 4954 6677Fax: (02) 4954 6033

299 Copland StWAGGA WAGGA NSW

Ph: (02) 6921 7606Fax: (02) 6921 1987

4 Young StDUBBO NSW

Ph: (02) 6884 4328Fax: (02) 6884 4362

Queensland 81-89 Northlink PlaceVIRGINIA QLD

Ph: (07) 3256 8958Fax: (07) 3256 8718

14 Leda Drv ANDREWS QLD

Ph: (07) 5576 8955Fax: (07) 5576 8975

South Australia 5 O’Connor CrtGEPPS CROSS SA

Ph: (08) 8349 5959Fax: (08) 8349 6659

The Zonemaster range caters for basic needs, through to sophisticated temperature sensitive models with programming ability.

Improving the efficiency of your Ducted Air Conditioning System

Page 2: The Principles of Zone Management for Efficient …ascentair.com.au/pdf/polyaireVAVtempcontrolzoning.pdf · Polyaire’s head office is based in Adelaide, South Australia (Along with

FEATUREWhat it is

ADVANTAGEWhat it does

BENEFITWhat it does for the user

Opens and closes up to 8 zones Available air flow is directed to required zones

Greater Efficiency

Energy Cost Saving

Greater Comfort

Radio Controlled Operation No long and expensive wiring or wall penetration to wire in

control module

Convenience: Can be operated from anywhere in the house

Remote Control Small, compact and can be used anywhere in premises

Easy and convenient to use, and the option of more than one

controller

Multi-Zone Variable Air Volume (VAV) Always be in your comfort zone

UniPoint SystemWhy waste energy by heating or cooling areas you are not using?

Radio Frequency System Directs air to areas in use - Increasing air conditioning efficiency

The Zonemaster Radio Frequency (RF) damper control system is similar to the UniPoint in that the RF system makes any ducted system more efficient by allowing air flow to rooms being used and stopping wasteful flow to unused spaces. This is a significant cost saving and a great benefit to the user in their ability to control the entire system from anywhere in the house. One hand-held controller is all that is needed. Extra controllers can be utilized, allowing you to keep one in the Lounge Room and one in the Master Bedroom. (Ideal for older or heritage houses with solid plaster wall and low roof applications where access to interior walls is difficult from above)

The system is 240volt and we suggest getting it installed at the same time as the ducted unit for greatest convenience.

The hidden advantage in using selective zoning is that, IF it is used properly and the zones are well planned, you could effectively only ever be heating or cooling half of the house! This means you can use a smaller unit than would be otherwise be possible without a zone control system. Considerable savings can be made.

NOTE: OPERATION PARAMETERSThe system is designed for the majority of Australian houses that are one storey with plasterboard or gyprock interior. The system’s range may be restricted in two storey or large house applications where the Radio Signal has to penetrate concrete slabs, double brick walls or steel barriers and where the distances are reaching the maximum range. In these instances a test unit should be used to ascertain acceptable operation (Available from your installer)

Receiver on Damper Motor

The Zonemaster VAV is a sophisticated Air Conditioner Management System that regulates temperature in each zone (both heating & cooling) by varying the volume of airflow from the Air Conditioning Unit.

It uses advanced electronics to continually sense the temperature in each zone and regulate the amount of cool or warm air so that the preset temperature is maintained. You may have a room in full sun and a study on the shady side of the house yet you want a similar temperature in both rooms. You program the VAV to the desired temperatures for each zone and the system will do the rest, varying the airflow to maintain the temperature you want in each room throughout the day. The VAV system is directing the available airflow where it is most needed, creating greater levels of comfort and efficiency.

An investment in a Zonemaster VAV can mean considerable savings in the size of the air conditioning unit needed and further savings through efficiency of flow management.

The Single Zone VAV system works on the same principal as the more sophisticated Multi Zone model explained above. It is designed to regulate one room or space that might be used infrequently but needs to be able to react to greatly increased heat loads in a short space of time. Some typical examples are:

• The Boardroom • The Dining Room

• The Lunchroom • The Home Theatre or Games Room

Each will instantly get an influx of people and require extra airflow to keep the temperature constant.

The Thermostat in the room controller senses the increased heat load and signals the Damper to open to maximum, to try and return the room to its set temperature. The only alternative to this is to keep the room air conditioned to the required level all the time which can be very wasteful in energy terms. It is programmable in similar fashion to the Multi Zone VAV above.

FEATURES:

• Senses changes in heat loads and automatically adjusts airflow accordingly

• Controls up to 16 zones

• Can be operated from all zones plus a central location

• Simple, one touch keypad operation

• Electronic zone labelling

• Supply air temperature safety function

• Activates powerful Variable Air Volume (VAV) dampers

• 5 year warranty

• All zones programmable for time and temperature

• Easy Installation 24 Volt Plug In

Single Zone VAV System

Remember that the VAV is managing air volume and not air temperature, which is set by the A/C unit. The VAV system will rarely achieve a temperature lower (cooling mode), or higher (heating mode) than that set by the A/C units temperature control.

All Zonemaster models are compatible with most Ducted Reverse Cycle Air Conditioners available in Australia.Please consult your installer.

The UniPoint system makes any ducted system more efficient by allowing air flow to rooms being used and stopping wasteful flow to unused spaces. One wall mounted controller is used to turn selected dampers on and off so that the available air flow is confined only to the rooms where it is needed.

Imagine you are sitting in the lounge after dinner and the kids have gone to bed. It’s been a hot day and everyone will need maximum cooling to get a good night’s rest. You use your Zonemaster UniPoint control to shut off all zones except the bedrooms. Restricting the airflow to the areas you need increases the available cool air and doesn’t waste power on cooling unoccupied rooms.

Maximum cooling for a comfortable night.

The UniPoint system is an on/off controller for up to 8 zones with the following features;

• Manual and programmable on/off time control

• LCD indicator for zone status and parameter display

• Real time clock with battery backup

• Room temp display using on board sensor

• 5-1-1 zone on/off program (5 Weekdays + Sat/Sun)

• Personalised zone labelling

• Easy Installation (24 volt plug in)

• Safety Protection

o Auto spill/ bypass – the designated spill zone is forced open if all zones switched off (to prevent Duct splitting)

o Temperature override – opens all dampers if air supply temperature is lower than low limit or exceeds high limit.

o After power loss all zones automatically return to previous on or off state when power restored

BENEFITS:

• Managing airflow so that the (cool or warm) air is only directed where you need it creates energy savings and greater comfort

• The programmable timer means that the zones can be set to open and shut at specific times for maximum efficiency

The MaxiPoint System

An upgrade of the UniPoint with up to 4 controllers (placed in different rooms) for greater convenience of use. Each controller interfaces with the others through a main control board (in the roof) so that the whole system can be accessed from any controller.

This means that the operator doesn’t have to walk from the bedroom to the kitchen to turn off the bedroom , they can use the extra control fitted in the bedroom. This is especially useful in large or two storey homes.

Controller 1

Controller 2

Controller 3

Controller 4

IT IS IDEAL FOR HOMES WHERE:

• Occupants have different temperature needs

• Different rooms have changing air conditioning needs at different times of the day

Time: 7.30pm, Dinner Area 24°C Time: 7.30pm, Bedroom 26°C Time: 7.30pm, Lounge Room 25°C

Multiple rooms - Different temperatures with the Zonemaster VAV

All Zonemaster systems are fully compatible with the extensive range of Polyaire Duct and fittings. Specify Polyaire air conditioning fittings to compliment your choice from the Zonemaster range.


Recommended