+ All Categories
Home > Documents > THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays,...

THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays,...

Date post: 30-Aug-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
4
biogas (anaerobic digestion) plants cogeneration heat and power engines (CHP) municipal or industrial waste water treatment sites coal seam gas sites (coal bed methane) food and animal waste processing plants biomethan (gas to grid) plants landfill sites The complete, ready to use biogas analyzer is the industrial solution to be used with: SWG100 VERSATILE for Biogas, Biomethane, Landfill Gas, Coalbed Methane THE ANALYZER
Transcript
Page 1: THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays, potential free contacts 24 Vdc/5 A RS485 digital interface (Modbus RTU) DIN-rail RS485

biogas (anaerobic digestion) plants

cogeneration heat and power engines (CHP)

municipal or industrial waste water treatment sites

coal seam gas sites (coal bed methane)

food and animal waste processing plants

biomethan (gas to grid) plants

landfill sites

The complete, ready to use

biogas analyzer is the

industrial solution to be used

with:

SWG100

VERSATILE

for Biogas, Biomethane, Landfill Gas, Coalbed Methane

THE

ANALYZER

Page 2: THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays, potential free contacts 24 Vdc/5 A RS485 digital interface (Modbus RTU) DIN-rail RS485

Instrument main features are:

industry compatible rugged design for harsh industrial environment

standard system safety included with continuously monitored fan ventilation

of cabinet, gas flow restrictor orifice at gas inlet

efficient sample gas preparation for fast and reliable measurements

sampling from low suction up to high pressure gas

no dilution of the sample gas, neither use of compressed air is required

direct and continuous/discontinuous measurement, with pressure and

temperature compensation and event data logging

up to 10 sites monitoring (time sharing technique) with only one analyzer

ready to run delivery, minimum installation work

Basic analyzer for wall (rack) mounting, IP54 aluminum cabinet with

anti-corrosive red structural lacquer

Monitored ambient air ventilation with display and system alarm,

including flow restrictor orifice and cutoff gas supply solenoid valve

Combustible gas detector (%LEL) mounted inside analyzer cabinet

Sample gas pump and internal sample flow monitoring with display

and system alarm

Solenoid valve for auto-zero with ambient air and calibration

1/8” threads for all sample gas, zero gas and calibration gas inlets,

fittings for DN6/4 mm tube

3,5” TFT color, backlit display and keyboard, password protected operation

RS485 digital data transfer (Modbus RTU)

115 or 230 Vac / 47 - 63 Hz / 90 W power supply

CH4 and CO2 NDIR measurement

O2 measurement with long-life EC cell

H2Slow measurement with EC cell protection (cut-off and purge)

H2Shigh measurement with EC cell

H2 or CO measurement with EC cell

Electric gas cooler (Peltier) with automatic condensate draining pump

Auto-calibration using span gas mixture cylinder

Multiple sampling point switchover from 2 x up to maximum 10 x sites

Module with 4 channel analog outputs/inputs 4 - 20 mA and 2 x alarm relays

Analyzer remote control using 4x external relay contacts

Converter module of RS485 into Profibus

Cabinet heater for freeze protection

SWG100 biogas standard option

SWG100

Page 3: THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays, potential free contacts 24 Vdc/5 A RS485 digital interface (Modbus RTU) DIN-rail RS485

MRU biogas analyzer of series SWG100, are designed for use in the harsh industrial environment of different

sites where biogas is produced.

The analyzer can be installed in outdoor or indoor location, can sample dry or wet biogas, pressurized or

low pressure gas and can be used from single point sampling up to max 10 sampling points.

Outdoor instalation requires sun and rain shade (user scope).

VERSATILE

for Biogas, Biomethane, Landfill Gas, Coalbed Methane

THE

ANALYZER

Up to 10x switching biogas inlets

Combustible gas detector (%LEL)

(time sharing technique)

with fail-safe shut-off solenoid

valves and flow restrictor orifice

NDIR bench for

CH4 / CO2

measurement

EC cells for

O2 / H2Slow /H2Shigh

with cut-off and purge

for H2Slow

Universal power115 or 230 Vac

47 - 63 Hz / 90 W

Continuous monitored ventilation fan with alarm

Cabinet heater 200 W

Internal sample

Automatic span

gas calibration

flow monitoring

Gas sampling pump

Up to 10x modules with analog outputs

4 x 4 - 20 mA , RS485 and

2 x alarm relays

Auto-Zero and

Auto-Cal

solenoid valves

Gas Cooler

Peltier type

Condensate

draining pump

Page 4: THE VERSATILE ANALYZER · 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays, potential free contacts 24 Vdc/5 A RS485 digital interface (Modbus RTU) DIN-rail RS485

Measured components

Measuring ranges

Measuring method

Calculated component

HMI human machine interface

System safety components

Sample preparation

Cabinet dimensions

Weight / Protection

Ambient temperature

Installation site

Cabinet conditioning

Power supply

CH4: 0 – 100 % (NDIR)

CO2: 0 – 100 % (NDIR)

O2: 0 – 25 % (electrochemical, continuous)

H2S low: 0 – 1000 ppm (electrochemical, discontinuous)

H2S high: 0 – 10.000 ppm (electrochemical, continuous)

H2: 0 – 1.000 ppm (electrochemical, discontinuous)

3Calorific value: 0 – 50 MJ/m ; MJ/kg

3,5” TFT color display

Backlit keyboard, password protected operation

4x analog output 4-20 mA, floating, max. load 500R

2 alarm relays, potential free contacts 24 Vdc/5 A

RS485 digital interface (Modbus RTU)

DIN-rail RS485 / ProfiBus converter

Monitored cabinet ventilation fan

Stainless steel flow restrictor orifice

Sample gas shut-down solenoid valve

LEL (CH4) monitoring inside cabinet

Stainless steel gas fittings with 1/8” ID threads

Electric gas cooler

Teflon particulate filter

Monitored and regulated sample flow 40…60 l/h

Sample inlet pressure: -100 mbar to + 300 mbar

Sample venting: atmosphere pressure

700 x 600 x 210 mm (H x W x D) for wall or rack mounting

25 kg / IP54

+5°C…+45°C or -20°C…+45°C with cabinet heater

Indoor or outdoor (rain and sun shade is mandatory user scope of supply)

Continuous, monitored fan ventilation

Cabinet heater 200 W (option)

115 or 230 Vac / 47 - 63 Hz / 90 W (300 W with cabinet heater)

TECHNICAL SPECIFICATIONS

MRU portable biogas and flue gas analyzers for CHP engine:

Simultaneous analysis of O2, CO2, CH4, H2S, NOx,

gas pressure and temperature,

with Li-Ion battery, SD card for data storage,

see more details and features on our website

DATA SUBJECT TO CHANGE WITHOUT NOTICE

MRU Measuring instruments for flue gases and environmental protection GmbH

Fuchshalde 8 + 12 • 74172 Neckarsulm - Obereisesheim

Phone +49 7132-99620 • [email protected] • www.mru.eu

W-6

53

33

GB

-K4

-XX

-05

6

VERSATILE

for Biogas, Biomethane, Landfill Gas, Coalbed Methane

THE

ANALYZER


Recommended