+ All Categories
Home > Documents > THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid...

THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid...

Date post: 18-Apr-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
5
THE ZERO ENERGY POOL SOLAR ELECTRICITY + POOL HEATING NATIONAL
Transcript
Page 1: THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid solar PV thermal technology is based on two principles: 1. Standard PV panels generate

THE ZERO ENERGY POOL

SOLAR ELECTRICITY + POOL HEATING

NAT I O NA L

Page 2: THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid solar PV thermal technology is based on two principles: 1. Standard PV panels generate

ONE FOOTPRINT, TWO SOLUTIONSA HYBRID PANEL THAT SIMULTANEOUSLY PRODUCES ELECTRICITY AND HEATING FOR YOUR SWIMMING POOL

The electricity generated by the high efficiency photovoltaic (PV) cells can cover all the electricity needs of your swimming pool (in particular, the pool equipment and in some cases, the heat pump). Any surplus electricity can be self-consumed in your home, or returned into the grid for a feed-in tariff or a net-metering program.

The internal heat exchanger allows direct connection to your pools water circuit. As the pool water flows through the heat exchanger, the water is heated whilst simultaneously cooling the panel, increasing the efficiency of the PV electrical generation.

THE BEST THINGS IN LIFE ARE FREEREDUCE YOUR ONGOING POOL HEATING COSTS TO ZERO

HOW DOES DUALSUN WORK?A TWO-IN-ONE SOLAR SOLUTION

ENHANCED PERFORMANCEDualSun’s unique design increases electrical output

100% RENEWABLE ENERGY

Self-sustaining energy and heating

production

PERFORMANCE OPTIMISATION

A range of solutions to maximise the use

of your system

EUROPEAN ENGINEERINGQuality French

design and manufacturing

RETURN ON INVESTMENTA responsible

investment that pays for itself

ELECTRICITYThe conversion of light into electricity is called the

photovoltaic effect. Solar panels convert energy from sunlight into direct current (DC) electrical energy, which is

then changed into alternating current (AC) for your home’s electrical consumption. Excess energy can be fed into a

battery storage system for later use, or returned to the grid for a feed-in tariff or a net-metering program.

WATERAs pool water is circulated through the heat exchanger

integrated into the underside of the photovoltaic surface, it absorbs the surplus energy created by the sunlight and photovoltaic effect. As a result, the water is heated and

returned to the pool whilst simultaneously cooling the panel and allowing the PV electrical generation to be maintained

at peak performance.

Page 3: THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid solar PV thermal technology is based on two principles: 1. Standard PV panels generate

100% RENEWABLE ENERGY

THE ZERO ENERGY POOL

There’s no doubt that your pool contributes a significant amount towards your electricity bill during swimming season. Whilst this may pose economic challenges to the average pool owner, the increasing impact on the environment’s natural resources has long lasting and far reaching effects.

Heatseeker DualSun provides a powerful solution for the swimming pool and spa industry, and more importantly for pool owners. The simultaneous generation of electricity and heated water allows the ongoing energy consumption of a pool to be neutralised, and avoid any government legislation that could negatively impact the industry.

Convert your investment into the zero energy pool, freeing yourself from the electricity companies by creating your own clean, reliable and 100% renewable energy.

STC SOLAR REBATE

The Australian Government Small-scale Renewable Energy Scheme creates a financial incentive for individuals and small businesses to install renewable energy systems such as DualSun. It does this through the creation of small-scale technology certificates (STCs).

STCs are provided ‘up front’ for the systems’ expected power generation over a 15 year period or, from 2017, from the installation year until 2030 when the scheme ends.

Generally, homeowners who purchase a DualSun system assign the right to create their certificates to a supplier/installer in return for a lower purchase price.

The number of STCs that can be created per system is based on its geographical location, installation date, and the amount of electricity that is generated or displaced by the system.

As a guide, one STC is equal to one megawatt hour of eligible renewable electricity.

* Commercial installations may be entitled to Large-scale generation certificates based on the amount of eligible renewable electricity they produce. For further information, please speak to your Supreme Heating representative.

A SOLAR PANEL SPECIFICALLY DESIGNED FOR

POOLS

INNOVATIVE HEAT EXCHANGER

Completely integrated into the panel, allowing for excellent heat transfer between the

photovoltaic surface and the water flow.

ULTRA THIN DESIGN Standard dimensions of a

photovoltaic panel (156mm cell, 60 cells).

HIGH PERFORMANCE PHOTOVOLTAICS

High efficiency monocrystalline cells cooled

by water circulation.

ENHANCED PERFORMANCE

THE EVOLUTION OF SOLAR POWER

DualSun’s hybrid solar PV thermal technology is based on two principles:

1. Standard PV panels generate much more heat (82.8%) than electricity (17.2%) when exposed to the sun.

2. The efficiency of PV panels decreases as the surface temperature increases.

The innovative DualSun hybrid solar panel utilises the excess heat from the PV cells, transferring it to the heat exchanger to produce heated water. In the process, the water circulation cools the PV cells, increasing efficiency by up to 20%. Therefore, a DualSun installation can utilise up to 4 times more energy than a standard photovoltaic installation.

Standard photovoltaic production

DualSun photovoltaic gain

DualSun thermal production

Page 4: THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid solar PV thermal technology is based on two principles: 1. Standard PV panels generate

Heatseeker DualSunTotal Savings = $66,560

Standard PV with the use of an inverter heat pumpTotal Savings = $33,495

Compared to a standard PV installation with the use of an inverter heat pump, Heatseeker DualSun will save youan additional $33,065 over the course of 20 years

YOUR SAVINGS OVER 20 YEARSEnergy expense savings over 20 years

Balance of Electrical Production$33,495

Electrical Production$46,515

Pool heating equivalent to use of inverter heat pump $13,020

Electrical consumption of inverter heat pump $13,020

DualSun Photovoltaic Gain $7,025

RETURN ON INVESTMENTDualSun VS Standard PV with use of a heat pump

Initial InvestmentAnnual Savings

Your investment pays for itself in 5.5 years

Heatseeker DualSun= $18,500= $3,328

Initial InvestmentAnnual Savings

Your investment pays for itself in 9.5 years

Standard PV with heat pump= $16,000= $1,675

DUALSUN ENERGY PRODUCTIONEnergy production over 20 years

Total: 335.6 MWh over 20 years

Electricity - 151.1 MWh

Heated Pool Water - 184.5 MWh

The equivalent of driving 13,555km/year in car.

The equivalent of 30.13 tons CO2 over 20 years.

The equivalent of planting 271 trees over 20 years.

Turn your investment into the zero energy pool with

Heatseeker DualSun

DualSun average daily production 20.7kWh/day

Average swimming pool requirements (pumps, lighting, sanitation) approx 10kWh/day

An investment in DualSun is an investment in quality. With over 700 successful installs since the company’s inception, DualSun has experienced a growth of 573% between 2013 and 2016 with

over 10,000m2 worth of panels being sold.

Created in 2010 by two engineers from one of France’s top engineering schools, Ecole Centrale Paris, the DualSun team is now based in Marseille where the sun reigns supreme.

Composed of young and dynamic engineers and designers with a passion for solar energy and a devotion to deliver the best hybrid solar solution for a transitioning

energy world, the DualSun team is supported by national and regional governments as well as numerous prestigious institutions.

With a no-compromise approach to quality, all manufacturing is performed exclusively in France by trusted suppliers.

With offices Australia-wide, Supreme Heating is DualSun’s exclusive distributor in the Australasian region.

RETURN ON INVESTMENTPERFORMANCE OPTIMISATION

QUALITY EUROPEAN ENGINEERING

The Heatseeker DualSun system not only allows you to sleep easy at night knowing you’re making the responsible choice when it comes to powering your pool, it also provides an excellent return on your investment through tremendous savings in energy costs of up to $66,560 over the course of 20 years.

Once your Heatseeker DualSun panels have collected energy from the sun, that energy needs to be converted from DC electricity to AC electricity for daily use in your home. DualSun is compatible with a range of options to help you achieve this. The correct option for you will depend on your individual needs, and will be discussed with you at time of consultation.

STRING INVERTERSString inverters work by collecting

the energy generated by your solar panels and converting the DC electricity to AC electricity through

a central location. Whilst string inverters are the most inexpensive option, they only perform as well as

the lowest-performing panel.

POWER OPTIMISERSPower optimisers are attached to

each panel where the electrical production is maximised and then

sent onto a centralised string inverter. Power optimisers ensure that the energy output of each individual

panel is utilised.

MONITOR YOUR PERFORMANCE

With DualSun, you can monitor your energy production levels as well as the performance and health of your system from an easy to access online interface.

Generate reports, share your data and track the performance of your investment over time.

MICRO INVERTERSMicro inverters are attached to each individual solar panel and convert the DC electricity

to AC electricity at the source of electrical generation, allowing

each panel to perform to maximum capacity.

Data based on 5kW system on an average size (32m2) swimming pool heated to 28°C for 6 months in Melbourne, Australia with the use of a pool cover 12hrs/day and an electrical cost of 35.4c/kWh as per Origin Energy January 2018. Pool heating expense is based on the alternative use of an inverter heat pump with a COP of 10. Data assumes all generated electricity is used in the home.

Page 5: THE ZERO ENERGY POOL - Australia Wide Solar · THE EVOLUTION OF SOLAR POWER DualSun’s hybrid solar PV thermal technology is based on two principles: 1. Standard PV panels generate

CLEAN ENERGY COUNCIL (CEC) APPROVED PV MODULE PV60129019 CERTIFIED IEC 61215 & 61730 AND SOLAR KEYMARK

DualSun panels are AS/NZS 5033-compliant for use in the design and installation of solar photovoltaic (PV) systems, as per CEC requirements, and are eligible for small-scale technology certificates (STCs). Heatseeker DualSun panels must be installed by CEC-accredited installers.

The panel underwent rigorous testing at the TÜV Rheinland laboratory in Germany proving its resistance to extreme temperatures, accelerated aging cycles, and violent projections.

The DualSun panel passed IEC and Solar Keymark certifications and is the first panel in the world to obtain the new PV/T Solar Certification.

GENERAL DATALength 1677 mm

Width 990 mm

Frame width 45 mm

Weight empty / filled 25 kg / 30 kg

Frame colour / backsheet Black / Black

Hail rating Rated to AS 2712-2007

ELECTRICAL DATANumber of cells per module 60

Cell type (dimensions) Monocrystalline (156mm x 156mm)

Nominal power (Pmpp) 280 Wp

Module efficiency 17.2 %

Power tolerance 0 / +3 %

Rated voltage (Vmpp) 31.95 V

Rated current (Impp) 8.77 A

Open circuit voltage (Voc) 38.88 V

Short circuit current (Isc) 9.30 A

Maximum system voltage 1000 V DC

Reverse current load 15 A

NOCT 49 °C

Connectors Genuine MC4

Application class Class A

Voltage (µVoc) -0.345 %/°C

Current (µlsc) -0.047 %/°C

Efficiency loss -0.467 %/°C

THERMAL DATAGross area 1.654 m2

Volume of heat transfer liquid 5 L

Maximum temperature 80 °C

Maximum operating pressure 1.2 bar

Pressure loss per panel 4000 Pa at 200 litres / hour

Hydraulic input / output 15 mm fitting

Optical efficiency a0 55.9 %*

Heat loss coefficient a1 15.8 W / K / m2*

Heat loss coefficient a2 0W / (m2.K2)*

*The a0 a1 and a2 coefficients are the measured values from testing during EN 12945 certification at the TÜV Rheinland for unglazed collectors : n0 = 0.570 ; c1 = 11.02; c2 = 0; c3 = 4.802; c4 = 0.62; c6 = 0.011; Kd = 1 with a wind speed of 1m/s.

Head Office 2/19 Enterprise Drive Bundoora VIC 3083 P: (03) 9460 [email protected] supremeheating.com.au

NSW Office 19/24 Anzac Avenue Smeaton Grange NSW 2567 P: (02) 4648 [email protected] [email protected]

QLD Office Unit 13, 53-57 Link Drive Yatala QLD 4207 P: (07) 3807 [email protected]

SA Office Unit 4, 7-9 Streiff Road Wingfield, SA 5013 M: 0437 947 [email protected]

WA Office South Fremantle WA 6162 P: (08) 9433 [email protected] supremeheatingwa.com.au

PV P

ERFORMANCE

WARRAN T Y

PRODUCT

WARRAN T Y


Recommended