+ All Categories
Home > Documents > Thermostatic Shower Restriction Valve –Measure Screening Results

Thermostatic Shower Restriction Valve –Measure Screening Results

Date post: 23-Feb-2016
Category:
Upload: hisa
View: 91 times
Download: 0 times
Share this document with a friend
Description:
Thermostatic Shower Restriction Valve –Measure Screening Results. New Measure Proposal February 19th , 2014. Measure background. Measure Name: Thermostatic Shower Restriction Valve Likely Measure Type:UES Likely Measure Category: Provisional - PowerPoint PPT Presentation
Popular Tags:
15
Thermostatic Shower Restriction Valve –Measure Screening Results New Measure Proposal February 19th, 2014
Transcript

Thermostatic Shower Restriction Valve –Measure

Screening ResultsNew Measure Proposal

February 19th, 2014

Measure background• Measure Name: Thermostatic Shower

Restriction Valve• Likely Measure Type: UES• Likely Measure Category: Provisional• Measure Sector: Residential• End-Use: Hot Water• Proposing Party: ShowerStart, LLC• Interested Party: Southern California Gas,

Ucons

Measure Definition and Specifications• Device works by slowing the water down to a

trickle once the hot water reaches the valve, thus saving the hot water that would be wasted down the drain when the shower is not being attended.

• In CA this measure is bundled with low flow showerheads.

Behavioral Waste Reduced by Thermostatic Restriction Valves• Original LBNL research (Lutz, 2011) investigated 36

shower events in 3 households.oOnly 5 events provided usable data.

• Recent study by the same author collected usable data from 60 shower events (8 homes, 13 bathrooms)o Study yet to be published by LBNLoBehavioral hot water waste occurs for approximately 45

seconds.

Measure Screening Assumptions• Water temperature and shower use assumptions taken from

(UES) Low Flow Showerheads measure workbook.o Inlet mains temperature is assumed to be 55 degrees F.o Mixed water temperature is calculated to be 108 – 111 degrees F,

depending on showerhead flow rate.o 370 showers per year, per showerhead

• Savings for four distinct showerheads with flowrate - 2.5, 2, 1.75, and 1.5 GPM.

• Electric water heater tank efficiency is assumed to be 100 %.

• Heat Pump COP assumed to be 2.5.

Measure Screening Assumptions• No NEBs were taken into account.

• Accounting for NEBs would increase the cost effectiveness of the measure.

• Measure cost assumed to be $16. Cost estimate provided by ShowerStart, LLC.

• Measure life assumed to be 10 years.o Measure life provided by ShowerStart (10,000 cycles) exceeded 10

years which is RTF approved EUL for showerheads.o ShowerStart EUL estimate verified by IAPMO (International

Association of Plumbing and Mechanical Officials – ANSI certified)

Measure Savings Estimate

0

20

40

60

80

100

120

140

2.5 GPM 2 GPM 1.75 GPM 1.5 GPM 2.5 GPM 2 GPM 1.75 GPM 1.5 GPM

Electric Water Heat Heat Pump

Annual Savings (kWh)

Measure Cost Effectiveness Estimate

0

1

2

3

4

5

6

7

8

9

2.5 GPM 2 GPM 1.75 GPM 1.5 GPM 2.5 GPM 2 GPM 1.75 GPM 1.5 GPM

Electric Water Heat Heat Pump

TRC

Staff Assessment• Staff believes that this measure could be developed

as a Provisional UES MeasureoMeasure is cost effective based on initial screening tests.o Staff to conduct a detailed review of the experimental

data provided by LBNL.o Staff to draft a Provisional UES Measure workbook and

research plan.oResearch plan will detail additional data required to

develop this measure into a UES measure.

RTF Proposed Motion:

“I _________ move that the RTF:

(Pick one)

1. allocate staff resources towards developing a Thermostatic Shower Restriction Valve Provisional UES measure, or

2. not allocate staff resources to developing a Thermostatic Shower Restriction Valve Provisional UES measure.”

Refrigeration Cycle Optimization –Staff Technology Review

New Measure Proposal February 19th, 2014

Technology Definition and Specifications• Instruments make it possible to attain system

performance data to optimize refrigeration and cooling system operation

• ClimaCheck manufactures two types of equipment that meet this specification:oPortable Installation: Portable ClimaCheck can be

connected to a desired system; it will provide equipment performance documentation within 30 minutes of connection.

o Fixed Installation: Fixed ClimaCheck equipment will provide continuous monitoring of equipment performance and energy consumption. Immediate feedback provided if maintenance required.

Sample Equipment

Actions Taken Since Last Meeting• RTF asked staff to further investigate the use of this

technology as a tool to estimate savings, or as a Standard Protocol.

• RTF Staff further reviewed the Refrigeration Cycle Optimization technology and found technology to be sound.o RTF Staff review was aided by Bob Davis (Ecotope).

• Staff spoke with James Anthony (BPA Contractor) and ClimaCheck to understand the energy efficiency measures this technology could best serve.

Staff Assessment• Staff recommends that Refrigeration Cycle Optimization technology is a

good tool to understand potential savings and system performance. • This technology is not a measure in itself.

• BPA contractor (James Anthony) thinks this technology could help better understand EER of grocery store refrigeration systems.o A large number of grocery measures would benefit from a better

understanding of EER.o He will investigate the usefulness of this technology and keep RTF staff up to

date of his findings and any data that is collected through this effort.

• Staff will keep this technology in mind while drafting Standard Protocols for refrigeration and HVAC measures in the future.o No further staff action required.


Recommended