This presentation describes the working functionality of HCTE (C&C08).
It fully details the process of call establishment and signaling paths through HCTE.
BOARD
RACK
MODULE
FRAME
RACKSMODULES
FRAMES
ASLCARD
1
2
32
DRV BNETOPT
NODDT
DT
DT
MPU SIG
ANALOG SUBSCRIBERS “BORSCHT” FUNCTION
INTEROFFICE DIGITAL TRUNKINTERFACE, 16 DTF = 960 CHANNELSAND 1 DTF = 2 PCM
PERFORMS COMMUNICATION
b/w MPU AND BOARDS IN USER
AND TRUNK FRAMES.
PERFORMS EQUIPMENT CONTROL, RECIEVES ASL AND TRUNK STATE THROUGH NOD BOARD AND SEND CORRESPONDING COMMANDS TO THEM. CONTROLS THE SIGNALS OF SIG BOARD (DIAL TONE, VOICE SIGNALS). ANALYZE THE CALLED AND CALLING PARTIES TO HELP OUT SWITCHING FOR THE NOS OF SAME SM.
RECEIVES DTMF SIGNALS,DRIVES HW SIGNALS ANDSENDS PORT SIGNALS
INTRA-MODULE SWITCHINGNETWORK BOARD, 4K X 4KSWITCHING NETWORK
40.96 Mbps OPTICAL INTERFACE TO OBC BOARD OF AM/CM OF HCTE.IT’S A PHYSICAL TERMINATION CARD.
Signaling path
Speech path
BAM
BCP
QSI FSN BAC
SPD
SRC
CID DISPLAY
SPCCPC
BCC
AMP
CDP
ALARM
SNU CNU
BDR
NCC
OBC
ET-16
STU
CKD CKS
EXCHANGEAM/CM
HDLCH
DLC
HDLC
HDLC2Mbps
8Mbps
393M O
ptical Interface
10 Mbps TCP/IP
10Mbps
2.048Mbps2.048KHz8KHz
2.048Mbps8KHz
SERIAL LINKRS-232
SERIAL LINK
RS-232 TCP/IP
WORK STATION
CNET
CCM
LIM
SRM SPM
CPM
CKM
SM
16 E1s
63 STM-1
Communication control module that
interlinks CPM, LIM,SPM and CNET
through HDLCAdmin and
maintenance processing and
online data setting.
Alarm board for all system alarm processing.
BUS control process board.Used for BUS
communication b/w AMP and
CDP.
Central database processing and management of common
resources.Deals location selection of PBX,
trunk line etc.
Provides communication bridge b/w OAM and WS.It consists of KVMS, LAN switches, Server and storage media.All the database and programs required by the system are stored here.
Centralized clock synchronization to
the whole exchange.
High Speed interface board that interconnects LIM,CNET and CCM.Provides Speech and Signaling path.
Line Interface Module provides linkage of
incoming and outgoing traffic to the AM/CM..It contains optical and
electrical interfaces at different data rates defined along with a specified capacity.
This unit performs routing and switching. It can understand the
prefixes. SNU is skirt N/W unit and CNU is the main central N/W unit.
NCC performs N/W communication control and BDR is the BUS driver for
the interface of this module.
Central Processing Module performs various important
tasks related to call processing. It performs alarm monitoring and processing, ticket
generation for the calls, duration calculation,
billing and routing etc.Service processing module provides a
variety of interfaces like R2
No.5 and implements SS7 system, provides signaling path.
MHI
Multi highway interface is a part
of LIM and provides 2M & 8M
HW
Shared resource module provides DTMF, MFC, Conference Telephone and FSK display device services.SPD is signal tone while SRC is shared resource card.
Des
tinat
ion
Work Station contains a software program that is used to configure boards, monitor
alarms, analyze traffic statistics, access the data at
BAM storage media and perform several other useful
tasks.
FOR DETAILS AND QUERIES PLEASE CONTACT.