TIA Portal V14 SP1 Technical slides Unrestricted © Siemens AG 2017
Transcript
  • TIA Portal V14 SP1 Technical slides

    Unrestricted © Siemens AG 2017

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations 5. System functions

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 2

    Details

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    S7-1500 CPU Portfolio has been enlarged by T-CPU

    Page 3

    Compact

    CPU

    Standard

    CPU

    Technology

    CPU

    ODK-

    CPU

    CPU-types 1511C-1

    PN

    1512C-1

    PN

    1511F-1

    PN

    1513F-1

    PN

    1515F-2

    PN

    1516F-3

    PN/DP

    1517F-3

    PN/DP

    1518F-4

    PN/DP

    1511TF-1

    PN

    1515TF-2

    PN

    1517TF-3

    PN

    1518F-4

    PN/DP

    ODK

    Interfaces

    Program/

    Data memory

    175 KB

    1 MB

    250 KB

    1 MB

    150/225 KB

    1 MB

    300/450 KB

    1.5 MB

    500/750 KB

    3 MB

    1/1.5 MB

    5 MB

    2/3 MB 8 MB

    4/6 MB

    20 MB

    225/225 KB

    1 MB

    750/750 KB

    3 MB

    3/3 MB 8 MB

    4/6 MB

    20 MB1)

    Bit-Performance 60 ns 48 ns 60 ns 40 ns 30 ns 10 ns 2 ns 1 ns 60 ns 30 ns 2 ns 1 ns

    Width 85mm 110mm 35mm 35mm 70mm 70mm 175mm 175mm 35mm 70mm 175mm 175mm

    Positioning axis

    typical 2)

    maximum 3)

    5

    10

    5

    10

    5

    10

    5

    10

    7

    30

    7

    30

    70

    128

    128

    128

    5

    10

    7

    30

    70

    128

    128

    128

    Motion Control

    Ressources 4) 800 800 800 800 2400 2400 10240 10240 800 5) 2400 5) 10240 5) 10240

    2) at 4ms Servo/IPO cycle time and 35% CPU load due to Motion Control

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    2 1

    1

    2 1

    1

    2 1

    1

    2

    3

    1

    1

    2

    3

    1

    1

    1

    1

    2 1

    1

    2

    1) 20 MB additional memory for ODK application

    4) Ressources for Motion Control technology objects (examples): Speed setpoint: 40; Positioning: 80; Gearing: 160; Output cam: 20; Output camtrack: 160; Measuring input: 40

    3) no further TO´s applicable

    March 2017

    PROFINET IO with IRT 2 PROFINET IO with RT 3 PROFINET basic services 1 5) Additional Number of Cam´s: 1511T: 20; 1515T: 60; 1517T: 128 PROFIBUS

    New

  • Unrestricted © Siemens AG 2017

    Easy handling of huge data amounts, which has to be kept retentive,

    e.g. in order to save settings or parameterization data during power

    off on the CPU.

    Migration of S7-400 applications in factory automation is possible

    Infeed of 60W into the backplane bus, integrated power balancing in

    the TIA Portal, connection to 24/48/60 V DC

    Energy buffering for data backup (up to 20 MB) in the CPU

    Can be used with standard- and fail-safe CPUs

    105mm width (can be plugged only on the left, next to the CPU)

    I&M 0 … 3 („electronic rating plate“ with article number, version, etc.)

    Highlights with PS 60W 24/48/60V DC HF

    Customer benefits:

    Page 4 March 2017

    Hardware configuration

    Configuration of the System Power Supply PS 60W 24/48/60V DC HF

  • Unrestricted © Siemens AG 2017

    Configuration in STEP 7 V14 SP1

    CPU firmware: V2.1,

    power supply for the CPU is done via the backplane bus

    Can be used with the following S7-1500 CPUs:

    CPU 1511(F/T) up to CPU 1516(F) with

    article number: 6ES751x-xyy01-0AB0 (starting with FS01)

    CPU 1511C and CPU 1512C (starting with FS01)

    CPU 1517(F) and CPU 1518(F) starting with FS03

    FS: Hardware functional state

    March 2017 Page 5

    Precondition for Configuration

    Hardware configuration

    Configuration of the System Power Supply PS 60W 24/48/60V DC HF

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Configuration of the System Power Supply PS 60W 24/48/60V DC HF

    Increased quantity structure for retentive data

    Identical handling of retentive data like before

    March 2017 Page 6

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Configure all IO channels of a module in a grid

    Configure all I/O channels

    of a module in a grid:

    All of the channels of the

    ET200MP DI&DQ HF

    can be configured in one

    grid.

    Improved overview and

    helpful functions like

    auto fill, copy & paste for

    diagnostics & IO

    parameters

    March 2017 Page 7

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Direct renaming of device names in the network and topology view

    Direct renaming of device

    names in the network and

    topology view

    Time savings thanks to

    direct renaming in the

    network and topology

    view without opening the

    device properties

    Renaming via F2

    shortcut, shortcut menu

    or by double-clicking on

    the device label

    March 2017 Page 8

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Optimized (multi-)selection via shift key for network and device editor

    1st click

    Shift key

    + 2nd click

    Optimized selection for

    network and device editor

    Quick (multi-)selection of

    several devices and

    modules with only two

    mouse clicks

    Support of device and

    network editor in all

    views

    March 2017 Page 9

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Overview of IO tags of the complete IO station

    Overview of all IO tags of

    a complete IO station

    Additional display for the

    IO tags of the complete

    IO station that are used

    Display structured

    according to modules for

    easy assignment of the

    IO tags to the hardware

    March 2017 Page 10

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Easy removal of unused GSD files

    1

    2

    3

    Easy removal of unused

    GSD files in the project

    Cleaning up of

    references to unused

    GSD files in the project

    Easy removing of

    unused GSDs from

    project with 3 clicks

    March 2017 Page 11

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Improved zoom and overview navigation for the device and network editor

    Improved zoom and

    overview navigation for

    the device and network

    editor

    The zoom function via

    toolbar controls now

    obtains the selected

    object in the visible area

    The overview navigation

    shows the complete

    configuration and

    automatically optimizes

    the display to the

    available area

    March 2017 Page 12

  • Unrestricted © Siemens AG 2017

    Hardware configuration

    Easy-to-find "PROFINET I/O system" properties

    Easy-to-find "PROFINET

    I/O system" properties

    Properties now also

    become visible by

    selecting the subnetwork

    All of the parameters of

    the subnetwork and

    PROFINET I/O systems

    in the overview

    March 2017 Page 13

  • Unrestricted © Siemens AG 2017

    HWCN editors

    Wizard extension for UDP multicast with Open User Communication (OUC) S7-1500 S7-1200 S7-300/400/WinAC

    Wizard extension for UDP

    multicast with Open User

    Communication (OUC):

    Easy UDP Multicast

    configuration for programmed

    or configured connections with

    S7-1500 incl. CM/CP

    Extension for CPU internal

    interfaces of S7-1500 V2.1 or

    higher

    March 2017 Page 14

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations 5. System functions

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 15

    Details

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

  • Unrestricted © Siemens AG 2017

    UDT and array comments can be changed instance-

    specifically

    Inheritance of defined comments by default

    Multilingual support

    S7-1500 S7-1200 S7-300/400/WinAC

    Customer benefits

    1. Display on the application

    2. Use for message text

    STEP 7 - Language innovations

    Freely editable comments for arrays and UDTs

    Function

    3. Further benefits

    Individual use of the

    same UDTs

    Unambiguous description

    of array elements

    March 2017 Page 16

    New

  • Unrestricted © Siemens AG 2017

    S7-1500 S7-1200 S7-300/400/WinAC

    New

    New

    SCATTER* converts elementary

    data types to a bit array

    GATHER* converts a bit array to

    an elementary data type

    Expanded instructions

    SCATTER_BLK and

    GATHER_BLK for "array of data

    type"

    Converting data for

    further processing

    STEP 7 - Language innovations

    New instructions: Scatter* / Gather*

    Breaking down, processing and

    status words

    Example use case

    March 2017 Page 17

    * from FW V2.1 (S7-1500), V4.2 (S7-1200)

  • Unrestricted © Siemens AG 2017

    New

    0

    1

    2

    3

    4

    5

    6

    7

    0 1 2 3 4 5 6 7

    x 1

    Output=3.5

    Input=5.5

    Characteristic line is defined as

    a polyline

    Up to 50 points

    Linear interpolation between

    points

    Input is mapped to

    output via characteristic line

    Use cases

    Adaption of measured values

    Linearization of actuators

    with nonlinear characteristic

    (e.g. compensation of valve

    characteristics)

    S7-1500 S7-1200 S7-300/400/WinAC

    STEP 7 - Language innovations

    New instructions: Polyline

    March 2017 Page 18

  • Unrestricted © Siemens AG 2017

    S7-1500 S7-1200 S7-300/400/WinAC

    Generation of a diagnostic entry when a user-defined service life

    is exceeded (in a percentage of the guaranteed read/write cycles)

    Visual indicator on the CPU via the maintenance LED

    Information in the user program can be evaluated via the

    "GetSMCinfo" block:

    Card size and memory that is already assigned

    Number of write and delete processes carried out for the

    card

    "Service life" display of the SIMATIC memory card

    RS ER MT

    80%

    FW

    2.0

    When recipes and archives are intensively used, information on

    the "service life" of the card can be evaluated and the SMC card

    can be swapped in advance if need be.

    Field of application New

    STEP 7 - Language innovations

    New instruction: GetSMCinfo

    March 2017 Page 19

    New

  • Unrestricted © Siemens AG 2017

    Easy back-up of various types of

    data

    Type safety because different UDTs

    can be assigned

    Compared to Serialize/Deserialize

    clearly better runtime behavior

    Various types of valves can be stored

    or manipulated in an array

    Customer benefits

    Use case

    STEP 7 - Language innovations

    Symbolic programming UDT1 := UDT2

    The various types of UDT must have the same structure of the

    individual elements.

    The symbolic names may differ.

    Requirements

    March 2017 Page 20

    S7-1500 S7-1200 S7-300/400/WinAC

    New

    Programming example

    :=

  • Unrestricted © Siemens AG 2017

    STEP 7 - Language innovations

    S7-Graph: Extension function block 1/2

    S7-1500 S7-1200 S7-300/400/WinAC

    With introduction of the expansion function

    block for S7-Graph all static variables can be

    accessed generically via the InOut interface.

    The created extension function block can be

    called as multi- or single instance.

    Customer benefits

    Indexed access to the whole sequence

    Access to internal parameters like - number of active steps (SAX)

    - number of disturbed steps (SERRX)

    - number of valid transitions (TVX)

    - and so on….

    Basic principle

    Call „My S7-Graph FB“

    My S7-Graph DB

    OB, FB, FC „My S7-Graph FB“,

    My S7-Graph DB

    New Extension

    function block

    March 2017 Page 21

  • Unrestricted © Siemens AG 2017

    STEP 7 - Language innovations

    S7-Graph: Extension function block 2/2

    S7-1500 S7-1200 S7-300/400/WinAC

    1) Create S7-Graph block (from V4.0)

    2) Create Extension function block*

    a) Define InOut parameters to access S7-

    Graph variables

    b) Sample program for indexed access to

    steps and transitions

    c) Sample program for access of internal

    parameters

    3) Define extension function block as multi

    instanz within the static-section of

    S7-Graph block

    4) Define the extension block name

    within the properties of the

    S7-Graph block.

    Workflow 1

    4

    2

    2a

    2b

    2c

    3

    * SCL only

    March 2017 Page 22

  • Unrestricted © Siemens AG 2017

    STEP 7 - Technology

    SIMATIC Ident: new technology object (TO) S7-1500 S7-1200 S7-300/400/WinAC

    The technology object for SIMATIC

    Ident is the link between the HW

    design and the SW programming

    The user allocates every device with

    a unique name which is also used for

    programming.

    Parametrization of hardware by the

    technology object

    Diagnostic by displaying messages

    that are produced within the

    application software.

    Basic principle

    March 2017 Page 23

  • Unrestricted © Siemens AG 2017

    STEP 7 - Technology

    SIMATIC Ident: Adressing scheme using TO S7-1500 S7-1200 S7-300/400/WinAC

    Easiest configuration

    1. Design hardware and network. Assign

    RFID devices with their own name.

    2. Call the TO window and select a RFID

    device.

    3. Adjust all parameter for the selected

    RFID device/reader.

    4. Select a RFID device in your

    application software. Only configured

    devices are shown in the drop dwon

    menu.

    3. Adjust parameter

    1. Design the hardware 4. Select device in

    function block of the

    application

    2. Call TO

    March 2017 Page 24

  • Unrestricted © Siemens AG 2017

    STEP 7 - Trace

    New options for graphical representation

    4

    3

    1

    Online

    Offline

    2

    5

    1. Preview window for the illustration

    and choice of the current zoom area

    2. Choice of the time format for the x-

    axis

    3. Display format for the number

    representation switch-selectable

    4. Switchover between steps and linear

    interpolated signal (REAL)

    5. Ongoing automatic measuring

    repetition

    Options

    Customer benefit

    Better Usability

    Page 25 March 2017

  • Unrestricted © Siemens AG 2017

    STEP 7 - Language innovations

    Collection of useful function expansions

    SCL: Surrounding a code that is used

    Selected code lines can be encompassed

    with control structures using the "Surround

    with" function.

    SCL: Insert and overwrite modes

    You can switch between

    insert and overwrite mode

    using the Ins key.

    Page 26 March 2017

    Insert mode Overwrite mode

    "Ins key"

    New

    New

  • Unrestricted © Siemens AG 2017

    STEP 7 – Editor innovations

    Collection of useful function expansions

    Page 27 March 2017

    Individual block comparison

    The detailed comparison of individual

    blocks can be started directly from the

    project navigation.

    Offline/offline but also online/offline

    Display of the tag comment

    In LAD/FBD, the tag comment can be

    displayed directly on the application.

    Hierarchical comments can also be

    displayed

    New

    New

  • Unrestricted © Siemens AG 2017

    STEP 7 - Editor innovations

    Collection of useful function expansions

    Tag comment in the watch table

    The defined tag comment can also be

    displayed in the watch table.

    Inserting a comment line in the watch table

    A comment line can be inserted using the

    new icon.

    "Open block/PLC data type..." via F7

    The F7 function can also be started within

    editors using Focus.

    Page 28 March 2017

    New

    New

  • Unrestricted © Siemens AG 2017

    STEP 7 - Editor innovations

    Collection of useful function expansions

    "Deep export" of external sources

    The export of objects as an external source

    takes the UDTs defined in the interface,

    multi-instances and all called blocks into

    consideration.

    Upgrade of the project version to the latest

    version

    In the Instructions task card, the project can

    upgraded to the latest version to be able to

    use all of the new instructions.

    Update of the instructions used in a

    controller

    All of the instructions used for a controller

    can be updated to the latest version in the

    Instructions task card.

    Page 29 March 2017

    New

    New

    New

  • Unrestricted © Siemens AG 2017

    STEP 7 - Editor innovations

    Collection of useful function expansions

    Settings for library types

    Under Settings/General/Library settings, the

    type cancellation of objects can be

    suppressed.

    Protection for unintentional cancellation

    of a typified object.

    Settings for user-defined help

    Under Settings/General, the user can select

    whether the user-defined help is to be

    opened in the selected editing language.

    Page 30 March 2017

    Terminate connection to type

    Corporate

    settings

    New

    New

  • Unrestricted © Siemens AG 2017

    STEP 7 - Editor innovations

    Collection of useful function expansions

    Export of PLC tags used

    The export of tag tables can be limited to

    the tags used in the project.

    Monitoring of blocks

    When monitoring blocks it will be shown

    whether online values are updated.

    Page 31 March 2017

    Ne

    w

    New

    New

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations 5. System functions

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 32

    Details

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

  • Unrestricted © Siemens AG 2017

    WinCC for Basic Panels

    Collection of useful function expansions

    Page 33 March 2017

    Functional improvements for Basic Panel

    Assignment of IP address is not limited to S7-1200 and S7-1500 anymore

    USB Rescue Stick to reset Panel if connection is not possible

    Siemens barcode scanners are now officially released with HMI Panels

    Download Chinese/Japanese/Korean fonts to Basic Panel

    (use of browser in these countries) via ProSave

    Picture and text in parallel on a button

    Unicode csv export of recipes on Basic Panels

    USB Reset to Factory with USB stick

    Creation of the USB stick

    download of software

    Unzip onto USB stick

    Copy of Image from TIA folder into folder of USB stick

    Start Basic Panel with inserted USB stick

    Follow instructions

    Restart the device

    Available via download or from hotline

    Preconditions:

    USB is FAT32 formatted

    Image is TIA V14 or higher

  • Unrestricted © Siemens AG 2017

    WinCC for Comfort / Mobile Panel

    Collection of useful function expansions

    Page 34 March 2017

    Functional improvements for Comfort / Mobile Panel

    Uninstall WinCE applications for Comfort Panels (via ProSave)

    Siemens barcode scanners are now officially released with HMI

    Panels

    Support of new network cameras

    Unlimited usage of scripts (no system limit anymore)

    Additional system functions in zone editor for Mobile

    System function for restart of Comfort Panels

    New supported printers:

    Brother HL-5100DN (black laser)

    Brother HL-L8250CDN (color laser )

    Connectivity – Tested products

    Support of Siemens barcode scanners

    Optical handheld reading devices MV320/MV325/MV340

    Update of tested network cameras

    AXIS M1013, AXIS M1011

    D-Link DCS-942L, D-LINK 4701E

    https://support.industry.siemens.com/cs/ww/en/view/62383298

    https://support.industry.siemens.com/cs/ww/en/view/19188460

    https://support.industry.siemens.com/cs/ww/en/view/62383298https://support.industry.siemens.com/cs/ww/de/view/19188460

  • Unrestricted © Siemens AG 2017

    WinCC for Mobile Panels 2nd Generation and Runtime Advanced

    Collection of useful function expansions

    Page 35 March 2017

    System functions for Mobile Panels 2nd Generation

    Evaluation of the connection point

    ShowPopUpScreen

    ShowSlideInScreen

    ShowLogonDialog

    Log on user, log off user

    VB script

    General enhancements for Runtime Advanced

    Camera view to display live video streams of current

    network cameras over RTP/RTSP streaming protocols

    and MJPEG, H264, MPEG4 codecs tested cameras

    (AXIS M1013, AXIS M1011, D-Link DCS-942L, D-LINK

    4701E, Siemens CCMS2025)

    Extension of PDF view (Find and Copy)

    License-free use of the Sm@rtServer on Runtime

    Advanced (analogous to Comfort Panels)

    ID 9 ID 8 ID 7

  • Unrestricted © Siemens AG 2017

    WinCC Runtime Advanced

    Integration of SINUMERIK Operate in Runtime Advanced

    Access to SINUMERIK Operate user interface via new NC

    Operate view in pictures of RT Advanced (also multitouch

    operation)

    Access to SINUMERIK NCU data by means of separate

    SINUMERIK channel

    Currently support of single-station solutions on SIMATIC IPC as

    well as standard PC with Windows 7 Professional operating

    system

    Requires ES option SINUMERIK Integrate Create MyHMI/WinCC

    as an enhancement for WinCC Advanced/Professional and RT

    option SINUMERIK Integrate Run MyHMI/WinCC for operation

    with WinCC Runtime Advanced

    Requires SINUMERIK Operate/PCU or /PC as of version 4.8

    SP1 or higher (customer-specific start of delivery scheduled for

    May 2017)

    Integration of SINUMERIK Operate (GUI and data)

    in Runtime Advanced

    March 2017 Page 36

  • Unrestricted © Siemens AG 2017

    WinCC Runtime Professional

    OPC UA DA Client

    OPC UA DA Client

    March 2017 Page 37

  • Unrestricted © Siemens AG 2017

    WinCC Runtime Professional

    Option WinCC/WebUX

    Option WinCC/WebUX

    March 2017 Page 38

    Info about used licenses

    Automatic Login ( “ViewOnly” for monitoring)

    Use Case: information display in manufacturing hall

  • Unrestricted © Siemens AG 2017

    WinCC Runtime Professional

    Collection of useful function expansions

    Collection of useful function expansions

    March 2017 Page 39

    Modal Popups with ScreenWindow

    The screens, shown in screen window can be locked (no operation)

    UseCase: InputMask, Messageboxes, ...

    VBS Method: „SetOperationLock()“

    Customizable Recipe Control

    Possibility to configure the following properties:

    Adapt the buttons (size and design)

    Elements of table (individual symbols, also dependent from tags)

    Scollbar (Style)

    https://support.industry.siemens.com/cs/ww/en/view/76327375

    https://support.industry.siemens.com/cs/ww/en/view/76327375https://support.industry.siemens.com/cs/ww/en/view/76327375

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations 5. System functions

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 40

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Details Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

  • Unrestricted © Siemens AG 2017

    SINAMICS Startdrive V14 SP1

    Optimized and extended commissioning wizard

    March 2017 Seite 41

    Integration of the previously two separated wizards

    for standard commissioning and the use with a

    SIMATIC Motion Control axis into one wizard

    Integration of the selection of telegram, brake

    resistance, filter at motor-side, temperature sensor

    as well as Motor selection also by code number

  • Unrestricted © Siemens AG 2017

    SINAMICS Startdrive V14 SP1

    Collection of useful function expansions

    Seite 42 March 2017

    Online/offline comparison of parameter

    values

    Track changes online / offline

    Sensitive support for saving data

    “RAM to ROM”

    Message box displayed when disconnecting

    from the drive (only if parameters have been

    edited)

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

    5. System functions

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 43

    Details

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

  • Unrestricted © Siemens AG 2017

    System functions

    Win10-Support for TIA Portal V14 SP1 incl. V13 SP2

    Supported operating systems

    New

    New

    V13 SP2

    V14 SP1

    01/2020 Windows 7

    10/2025 Windows 10

    End of ext.

    support:

    Use case

    project upgrade

    V13 V14

    Customer benefits

    Long-term Microsoft Windows support with Windows 10

    One shared operating system platform for TIA Portal and

    "Classic products"

    Project upgrade to a single-station computer :

    Vxx V13 SP2 V14 SP1

    March 2017 Page 44

    * planned Q2/2017 * for STEP 7 / WinCC Basic also Windows 10 Home

    *

  • Unrestricted © Siemens AG 2017

    System functions

    Password API

    Protected

    program

    blocks

    TIA Portal / STEP 7

    Password prompt

    via API

    Integrated UI behavior:

    Password prompt via dialog

    KHP-PW

    Central server management

    with user authentication

    User-specific hardware dongle

    ID card with

    Smartcard chip

    Application examples

    New

    Open interface for 3rd party tools to connect to

    the TIA Portal

    Definition or administration of passwords in

    external tools

    Automatic opening of know-how-protected

    blocks without entering a password

    Supported protective mechanisms:

    - Know-how protection for PLC objects

    - Write protection for PLC objects

    - Copy protection for PLC objects

    Increased know-how protection because

    passwords for the users are not visible/known

    More convenient working with protective

    mechanisms

    Function

    Customer benefits

    Passw

    ord

    AP

    I

    March 2017 Page 45

  • Unrestricted © Siemens AG 2017

    System functions

    Filter options for cross-references

    1 New 2

    3

    Example use case

    As a user, I would like to find all variable write

    accesses in a block greater than 1.

    Workflow

    1. Select all of the variables and open the

    cross-references ("F11" or inspector window)

    2. Define filter

    3. The filter results show only multiple

    accesses

    Specific information is quickly found

    Project-independent, can be saved and

    exported

    Customer benefits

    Filter options

    March 2017 Page 46

  • Unrestricted © Siemens AG 2017

    Library

    Export

    System functions

    Translation of libraries

    B1 ENG GER

    B2 ENG GER

    V 1.0.0

    V 0.3.2

    Translation

    ENG CHN

    Text 1 …

    Text 2 …

    … …

    ENG GER

    ENG GER

    V 1.0.0

    V 0.5.9

    ENG GER

    ENG GER

    Library

    B1 ENG GER CHN

    B2 ENG GER ITA

    V 1.0.0

    V 0.3.2

    ENG GER

    ENG GER

    V 1.0.1 ENG GER CHN

    V 1.0.0

    V 0.5.9

    ENG GER

    ENG GER

    V 1.0.1 ENG GER CHN

    Import

    Customer benefit

    Translation of a library

    Translation functions available for

    project and

    global libraries

    The import/export of texts can be

    done for a complete library, for

    several library elements, or an

    individual library element.

    Consistent handling for copy

    templates and types

    March 2017 Page 47

  • Unrestricted © Siemens AG 2017

    System functions

    Library functions – Type upgrade – With TIA Portal V14 SP1

    Function

    Integration of deltaobjects for existing

    types

    System supported integration of

    changed objects into an existing

    library

    Customer benefit Workflow

    1. The filter shows all of the types that can

    be upgraded

    2. The user selects the test environment

    3. The system checks the prerequisites

    4. The system performs the upgrade of the

    selected types

    Blue markings appear if the types in the PLC_1 are instantiated.

    1 2 4

    3

    Page 48 March 2017

  • Unrestricted © Siemens AG 2017

    V13 SP1-Project V14 SP1 Project

    V14 SP1 Engineering Software

    Project Upgrade to V14 SP1

    All project versions can be accessed via side-by-side Installation of V13 SP2 and V14.

    V13 SP1/SP2

    (usage also with V14 license )

    Project Upgrade to V13 SP1

  • Unrestricted © Siemens AG 2017

    V14 Project

    V14

    V14 Engineering Software

    V14 SP1 Project

    V14 SP1

    System functions

    Online-Compatibility

    Page 50 March 2017

    No Online/Offline difference

    No download or STOP necessary for:

    Go Online

    Monitoring blocks

    Control variables

    SW-Download in RUN (HW-Download always in STOP)

    PLC-Upgrade from V14 to V14 SP1

    Online access after upgrade of project

    Customer benefits

    No machine interruption by project upgrade

    Program corrections can be downloaded in RUN

    No lost of actual value

    Upload in ES Download in PLC Online & Diagnosis Monitoring

    Project Upgrade

    Online Upgrade via

    download in RUN

    New

  • Unrestricted © Siemens AG 2017

    System functions

    Basic Integrity Check

    TIA-Portal features a base-protective

    mechanism to detect changes in custom project

    file (e.g. blocks, hardware configuration).

    Causes for changes for example can be

    tampering outside the TIA-Portal or defects in

    the data storage medium.

    The TIA-Portal automatically extends integrity

    information to the project file during save

    operation

    The check can be performed individually when

    opening a project or generally during project

    open (Global Setting)

    Function

    March 2017 Page 51

    Improved detection of modifications on TIA-

    Portal project files.

    Customer benefits TIA-Portal Project

    File

    Ad

    din

    g i

    nte

    gri

    ty

    info

    rma

    tio

    n

    Op

    tio

    na

    l c

    he

    ck

    of

    inte

    gri

    ty i

    nfo

    rma

    tio

    n

    TIA-Portal

    Save project

    Open project

    1

    2

    1

    2

    Note: If basic integrity check is activated operating speed is reduced

    when opening projects and especially in multi-user scenarios

  • Unrestricted © Siemens AG 2017

    March 2017

    System functions

    Collection of useful function expansions

    page 52

    Write protection for program blocks

    Password based write protection –

    code visible but not editable

    Also for failsafe block

    (F signature is not changed)

    Blocks still can be compiled

    New properties and improved

    usability in the alarm display

    Receive alarms can be activated

    within inspector window

    With “freeze alarms” the view of the

    alarm display can be frozen

    New

    New New

  • Unrestricted © Siemens AG 2017

    TIA updater: Fast mass update

    Openness: Ex/Import HW +IO via AutomationML

    ProDiag: Criteria analysis for S7-Graph

    Safety: Consistent Hardware- and Software Upload

    Option handling with S7-1500F

    F-IO-Status function block

    6. TIA Portal options 2. STEP 7 - Innovations

    Freely editable comments for array and UDT

    New instructions

    Single block comparison

    User comments visible directly in the code

    New technology object for SIMATIC Ident

    3. WinCC - Innovations Windows 10 support

    Password API

    User-defined filters for cross-references

    Library handling

    5. System functions

    1. Hardware configuration

    Support for new hardware components

    - CPU1511T(F) / CPU1515T(F)

    - Power Supply 60W 24/48/60V DC HF

    New functions for the operability

    TIA Portal

    Highlights of TIA Portal V14 SP1

    March 2017 Page 53

    Details

    Optimized and extended

    commissioning wizard

    Online/offline comparison of parameter

    values

    4. Startdrive - Innovations

    Integration of SINUMERIK Operate in Runtime Advanced

    OPC UA DA client for WinCC Runtime Professional

    WinCC WebUX- Auto Login for WinCC RT Professional

  • Unrestricted © Siemens AG 2017

    Function

    Multi-selection of support packages

    Automatic download and installation of

    several support packages

    TIA Portal options

    TIA Software Updater

    Quick and easy adding of support

    packages

    Customer benefits

    New New

    TIA Software Updater

    March 2017 Page 54

  • Unrestricted © Siemens AG 2017

    Replacement of hardware configuration and icons via XML files

    Bidirectional workflow CAD systems TIA Portal

    Free tool support thanks to a standardized interface

    Further use case, e.g. TIA Selection Tool connection

    HWCN + IO

    Exp

    ort

    /im

    po

    rt

    PLC_1

    XML file PLC_2

    XML file

    IO-

    Device_1

    AML file

    Exp

    ort

    /im

    po

    rt

    TIA Portal V14 SP1 Electrical CAD tools

    Customer benefits

    TIA Portal options

    Openness: Standardized exchange between Electro-CAD and automation

    Article number

    Article description

    Network connections

    Configured firmware version

    Tag table

    New

    March 2017 Page 55

  • Unrestricted © Siemens AG 2017

    Project for Machine B

    Project for Machine A

    TIA Portal options

    Openness: Automatic generation of projects, software and hardware

    Project generator

    DLL

    TIA openness TIA Portal

    Customer benefits

    Generation of the

    complete automation

    project with TIA Portal

    openness (hardware &

    software)

    Perfect customer workflow

    from ordering to the

    finished automated TIA

    project.

    March 2017 Page 56

  • Unrestricted © Siemens AG 2017

    Why?

    Original

    problem

    Switchover of the view to the original

    state when an error has occurred.

    Function

    TIA Portal options

    ProDiag: Criteria analysis in the HMI PLC Code Viewer

    Customer benefits

    Focusing on the erroneous operands

    March 2017 Page 57

  • Unrestricted © Siemens AG 2017

    TIA Portal Optionen

    STEP7 Safety: Consistent Upload of Safety projects

    K

    R

    E

    I

    S

    CPU 1 ET200SP 1

    CPU 3 ET200SP 3

    CPU 2 ET200SP 2

    Pro

    ject

    1

    Pro

    ject

    2

    Pro

    ject

    3

    Service Techniker

    Upload consistent

    Avoidance of faults and

    reduction of the service effort by

    reduction of complex “offline”

    administration

    Time and cost savings

    For S7-1500F and also

    PLCSim Advanced

    Customer benefits

    Page 58 March 2017

  • Unrestricted © Siemens AG 2017

    TIA Portal Optionen

    STEP7 Safety: Configuration Control for F-I/O

    K

    R

    E

    I

    S

    F-modularization and fast

    customization on customer wishes

    without ES for serial production of

    machines

    Supported for F-Periphery

    dezentralized for F-PLC S7-

    300/400/1200/1500 und centralized

    for F-CPU S7-1500

    Controlling via F-Periphery-DB-

    Variable „DISABLE“

    Analysis of the F-BG-deactivation

    via „DISABLED“ F-DB-Variable

    Customer benefits

    from Safety-System-Version V2.1

    Page 59 March 2017 3/31/2017 Page 59

    CP

    U 1

    Master-Project

    CP

    U 1

    Option 1

    CP

    U 1

    Option 2

  • Unrestricted © Siemens AG 2017

    TIA Portal Optionen

    STEP7 Safety: F-IO-Status function block

    K

    R

    E

    I

    S

    Collective information of channel- or F-I/O

    faults for each failsafe Runtime Group

    „QSTATUS“ Bit (QBAD + Value_Status)

    Separate collection of the RIOforFA-

    Value-Status for all F-IO modules

    Extensions for further F-I/O information

    planned (PASS_OUT, ACK_REQ,

    IPAR_OK, …)

    Customer benefits

    New

    March 2017 Page 60

  • Unrestricted © Siemens AG 2017

    Thank you for your attention.

    Page 61

    Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may

    not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested

    performance features are binding only when they are expressly agreed upon in the concluded contract.

    All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties.

    Their unauthorized use may infringe the rights of the respective owner.

    siemens.com/tia-portal

    March 2017


Recommended