5"
12"
5"
12"5"
12"5"
12"
5"
12"
5"
12"
5"
12"
5"
12"
FINISH FLOORELEV. @ 0"
FINISH FLOORELEV. @ 0"
TOP OF BEAMELEV. @ 9'-4"
TOP OF BEAMELEV. @ 9'-4"
6" RAISED BANDING
LAP SIDING
6" RAISED BANDING
DECO FINISH
16080 OHGD25 SH3080 ENTRY
TILE ROOF
8'-0
"
FREIZE BOARD
1'-4"1'-4"1'-4"
FINISH FLOORELEV. @ 0"
FINISH FLOORELEV. @ 0"
TOP OF BEAMELEV. @ 9'-4"
TOP OF BEAMELEV. @ 9'-4"
8'-0
"
2-25 SH2-4080 SL GL DR
TILE ROOF
DECO FINISH OVER
CONC. BLOCK
1'-4"1'-4"
FINISH FLOORELEV. @ 0"
FINISH FLOORELEV. @ 0"
TOP OF BEAMELEV. @ 9'-4"
TOP OF BEAMELEV. @ 9'-4"
DECO FINISH OVER
CONC. BLOCK
TILE ROOF
2-25 SH
2'-3
"
LAP SIDINGLAP SIDING
8'-0
"
1'-4"1'-4"
1'-4"
FINISH FLOORELEV. @ 0"
FINISH FLOORELEV. @ 0"
TOP OF BEAMELEV. @ 9'-4"
TOP OF BEAMELEV. @ 9'-4"
DECO FINISH OVER
CONC. BLOCK
8'-0
"
TILE ROOF
23 SH 25 SH
1'-4"1'-4"
48" x 12"
DECO FOAM #
BKT 12" x 16"
1'-4
"
11 1/2"
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
1/4" = 1'-0"
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-1 ER
ELEVATION
1543
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
FRONT ELEVATION "ER"
1/4" = 1'-0"
REAR ELEVATION "ER"
1/4" = 1'-0"
LEFT ELEVATION "ER"
1/4" = 1'-0"
RIGHT ELEVATION "ER"
WH
HB
HB
PROVIDE 1/4" WATER
LINE @ REF SPACE
FOR ICE MAKER
STANDARD SGD RECESS 1-1/2".
IMPACT GLASS SGD RECESS 2-1/2".
4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #
10/10 W.W.M. REINFORCING OVER 6
MILL VISQUEEN BARRIER ON
MECHANICALLY COMPACTED FILL @ 95%.
THE FINISH FLOOR SLAB SHALL BE SET
ABOVE BASE FLOOD ELEVATION PER FEMA
FLOOD MAP PLUS 1'-0" FREEBOARD PER
FBCR R322.2.1. SEE SITE PLAN BY OTHERS
ELEV. @ 0'-0"
ELEV. @ -0'-(-4")
ELEV. @ -0'-(-4")
ELEV. @ -0'-(-4")
SLO
PE
4'-6
"1
'-6
"5
'-9
1/2
"
24'-4" 3'-6" 2'-2"
1'-1 1/2" 3'-5" 3 1/2" 17'-6" 2'-8" 5'-0"
AHU
1'-4
"5
'-8
"4
4'-9
"7
'-6
"1
'-4
"1
5'-5
"
76
'-0
"
1'-4" 13'-2" 15'-6"
30'-0"
76
'-0
"
1'-4" 9'-4" 8" 1'-4" 16'-0" 1'-4"
30'-0"
REF.
SPAC
E
WASHER DRYER
DBL. SINK
30'-0"
5'-4" 9'-9" 4'-0" 8'-8 1/2" 2'-2 1/2"
3'-8" 8'-2" 2'-8"
11'-4" 18'-8"
14
'-2
"2
'-6
"4
'-3
1/2
"
LOWEST POINT OF GARAGE SHALL BE SET ABOVE
BASE FLOOD ELEVATION PER FEMA FLOOD MAP
SET A/C PAD ABOVE
FLOOD W/ 1'-0"
FREEBOARD PER
FBCR R322.2.1
6" X 12" RECESS
16'-0" X 8'-0" O.H.G.D.
5'-0" TUB/SHWR
PAVERS BY OTHERS
PAVERS BY OTHERS
20
'-8
"6
'-1
0 1
/2"
1'-3
"7
'-5
"1
8'-7
1/2
"3
'-1
"1
'-0
1/2
"1
7'-0
1/2
"
TILE SHOWER
RECESS 3 1/2"
SET W/H ABOVE FLOOD W/ 1'-0"
FREEBOARD PER FBCR R322.2.1
DW
PROVIDE TERMITE TREATMENT
WITH "BORA CARE"
OR DOORS
21" MIN. TO
FIXTURES, WALLS 1'-9"
8'-0
"36" MAX.
OR DOORS
21" MIN. TO
FIXTURES, WALLS
MIN.
1'-0"
19
" M
IN.
19
" M
IN.
15" MIN.
TO FINISH
FRONT ELEVATION SIDE ELEVATION
WATER CLOSET CLEARANCE DETAIL
8'-0
"
FRONT ELEVATION SIDE ELEVATION
VANITY SINK CLEARANCE DETAIL
4"
2'-5
1/2
"
8'-0
"
VARIES
4"
2'-5
1/2
"VARIE
S
VARIES
8'-0
"
MIRROR
FAUCET
KICK PLATE
FAUCET
MIRROR
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-2 ER
SLAB & PLUMBING PLAN
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
SLAB & PLUMBING PLAN "ER"
WH
HB
HB
14'-6" 15'-6"
7'-0
"4
4'-9
"8
'-1
0"
15
'-5
"
13
'-1
0"
2'-1
0 1
/2"
2'-6
"3
'-2
"4
'-5
1/2
"1
0'-8
"2
'-4
"8
'-8
"6
'-6
"2
1'-0
"
5'-4" 2'-2" 10'-6" 4'-0" 8'-0"
76
'-0
"
11'-4" 18'-8"
15'-1 1/2" 4'-0" 10'-10 1/2"
LANAIBEDROOM #1
KITCHEN
NOOK W.I.C.
BATH #1
BEDROOM #2
GREAT ROOM
STUDY/ DEN
BATH #2
LAUNDRY
GARAGE
FOYER
ENTRY
30'-0"
9'-4" FLAT CEILING
AHU
4'-2
"5
'-4
"6
'-4
"4
'-0
"1
6'-8
"2
'-2
"1
0'-1
"
1'-10" 6'-2"
12" SHELF
12" S
HELF
12'-7 1/2" 2'-4" 15'-0 1/2"
1'-4
"3
'-6
"4
'-0
"
1'-4" 9'-4" 8"
33
'-4
"1
4'-6
"1
3'-5
"1
4'-9
"
1'-4" 13'-2" 4'-8" 10'-10"
1'-4
"5
'-8
"2
5'-3
"1
9'-6
"
1'-4" 3'-0" 6" 2'-3" 4'-3"
1'-4" 16'-0" 1'-4"
12" S
HELF4
2
2
2
2
4
6
12" SHELF
2
2
2
2
8
3
C
BA
C
1
76
'-0
"
30'-0"
MIN. R-13 OR
BETTER INSULATION
22" X36"
ATTIC ACCESS
SEE NOTE 10
SEE NOTE 9
4
6
3'-8" 8'-2" 2'-8"
REF.
SPAC
E
DBL. SINK
RANG
E
DRYERWASHER
6'-1
0"
2'-1
0"
6'-4
"
5'-0" TUB/SHWR
MIR.
MIR
.
6" WALL
6" WALL
SAFETY G
LAZED
6" KNEE WALL
34 1/2" TALL
LINEN
6
12" S
HELF
12" S
HELF
PANTRY
2
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
TIL
E S
HO
WER
RECES
S 3
1/2
"
OVRH
EAD
CABS
SAFETY G
LAZED
D
FULL GLASS
DW
OVRH
EAD C
ABS
3'-4
"
9'-11"
FACE OF OUTSIDE WALL TO FACE OF STUD WALL FACE OF STUD TO FACE OF STUD
1/2"
3 1/2"
1/2"
FACE OF EXTERIOR WALL
1/2"
3 1/2"
1/2"TYPICAL DIMENSION STRING
DOOR HEADERS6'-8" BI-FOLD
6'-8" SWING
8'-0" SWING
HEADER HEIGHT 82" A.F.F.
82 1/2" A.F.F.
98 1/2" A.F.F.
HEADER HEIGHT
HEADER HEIGHT
PLAN NOTES
1) VERIFY ALL ROUGH OPENING DIMENSIONS FOR
ALL WINDOWS AND DOORS
2) PROVIDE SAFETY GLAZING WITHIN 24" FROM EXIT
PER FLORIDA BUILDING CODE R 308.4.2.
3) PROVIDE SAFETY GLAZING AT BATH/ SHOWER
PER FLORIDA BUILDING CODE R 308.4.5.
4) NON BEARING INTERIOR FRAME WALLS SHALL BE
FRAMED W/ WOOD OR METAL STUDS. SPACING SHALL
NOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)
5) PROVIDE DEAD WOOD IN ATTIC FOR OVERHEAD
GARAGE DOOR HARDWARE
6) KITCHEN KNEE WALL TO BE FRAMED W/ TOP @
34 1/2" A.F.F.
7) INSTALL SMOOTH WALLS IN KITCHEN AND ALL
BATHROOM AREAS
8) WHERE DRYWALL CEILING IS APPLIED TO TRUSSES
@ 24" O.C. USE 5/8" DRYWALL OR 1/2" SAG
RESISTANT PER SEC. 702.3.5
9) THE GARAGE SHALL BE SEPARATED FROM THE
RESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUM
BOARD APPLIED TO THE GARAGE SIDE. GARAGES
BENEATH HABITABLE ROOMS SHALL BE SEPARATED
WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD
OR EQUIVALENT. WHERE THE SEPARATIION IS A
FLOOR - CEILING ASSEMBLY, THE STRUCTURE
SUPPORTING THE SEPARTION SHALL ALSO BE
PROTECTED BY NOT LESS THAN 1/2" GYPSOM BOARD
OR EQUIVALENT
10) INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEEN
LIVING AND GARAGE PER FLORIDA BUILDING CODE
R302.1.5.
11) ALL WINDOWS INSTALLED 72" ABOVE GRADE MUST
COMPLY WITH R612.2 MIN 24" SILL HEIGHT OR
PROVIDED WITH AN APPROVED WINDOW FALL
PRVENTION DEVICE
12) ALL CLOSET SHELVES TO BE 12". ALL PANTRY &
LINEN TO BE (4)-16" SHELVES 18" 0.F.F. W/ 15"
INCREMENT.
13) ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BE
INSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.
CABINET BACKINGKITCHEN
MASTER BATH
GUEST BATH
LAUNDRY ROOM
UPPER TOP @ 84" BASE TOP @ 35"
UPPER
UPPER
UPPER TOP @ 84"
BASE TOP @ 35"
BASE TOP @ 31"
BASE
TOILET PAPER ROLL
2'-6"
1'-8"
TOWEL BAR
4'-0"
3'-2"
MIN.
4"
MIN.
4"
BATHROOM NOTES
ALL TUB DECKS @ 21" A.F.F
ALL BLOCKING TO BE PT IN SHOWERS
TOWEL BAR
TP TOILET PAPER
TB
INTERIOR DOOR SCHEDULE
MARK
1
2
3
DOOR WIDTH NOTES
P.K. = POCKET DOOR
B.F. = BI-FOLD DOOR
B.P. = BI-PASS DOOR
L.V. = LOUVERED DOOR
4
5
6
7
8
3'-0"
2'-8"
2'-6"
2'-4"
2'-0"
1'-8"
1'-6"
2'-10"
OPT IMPACT GLASS MAY BE INSTALLED IN
LIEU OF SHUTTERS VERIFY W/ CONTRACT
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-3 ER
FLOOR
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
FLOOR PLAN "ER"
WINDOW SCHEDULE
MARK
DESCRIPTIO
N MANUFACTURER HEIGHT WIDTH COMMENTS QTY
A 25 SH 5'-1" 2'-11" 2
B 23 SH 3'-0" 2'-11" 1
C 2-25 SH 5'-1" 6'-2" 2
D 48" X 12" FIXED GLASS 1'-0" 4'-0" 1
DOOR SCHEDULEMARK DESCRIPTION MANUFACTURER HEIGHT WIDTH COMMENTS QTY
1 16080 OHGD GARAGE DOOR 8'-0" 16'-0" 1
2 3080 ENTRY 8'-0" 3'-0" 1
3 2-4080 SL. GL. DR. 8'-0" 8'-0" 1
SQUARE FOOTAGE
LANAI AREA 102 SF
LIVING AREA 1544 SF
GARAGE AREA 383 SF
ENTRY AREA 74 SF
TOTAL AREA 2102 SF
WH
HB
HB
BATH #1
STUDY/ DEN
GARAGE
HIP
VAL
LEY
HIP
RID
GE
RID
GE
HIP
HIP
LANAI BEDROOM #1
KITCHEN
NOOK W.I.C.
BEDROOM #2
GREAT ROOM
BATH #2
LAUNDRY
GARAGE
FOYER
ENTRY 22" X36"
ATTIC ACCESS
6" WALL
6" WALL
9'-4" FLAT CEILING9'-4" FLAT CEILING
9'-4" FLAT
CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
MODEL 1543 E: ATTIC VENTILATION FBCR R806
SOFFIT ONLY (1/150) WITH ROOF VENTS (1/300)
AREAS (SQ. FT.) ATTIC VENTILATION REQUIRED ATTIC VENTILATION REQUIRED
MARK SOFFIT
2384.4 SQ. FT.
ATTIC AREA/150
5.70% -.-- SQ. FT. -.-%
COORDINATE VENTING REQUIREMENTS WITH ENERGY CALCULATIONS
(R.V.)
ROOF VENTS ARE NOT REQUIRED
32" BASE
22
-3/8
" BASE
LOMANCO 770-D
0.97 SQ. FT. FREE AIR
(NO ROOF VENTS)
15.9 SQ.FT.
"SOFFIT ONLY" QUALIFIES
SOFFIT MODEL
ACM QUAD 4, FULL VENT,
NARROW PATTERN,
8.15% FREE AIR FLOW
ATTIC
279.1 SQ. FT.
MIN AIR FLOW OF SOFFIT
ROOF VENT MODEL
1st STORY
REQ'D AIR FLOW
OF SOFFIT
QUAD 4 SOFFIT
HAS
8.15%
ATTIC AREA/300QUANTITY OF
ROOF VENTS
-
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-4 ER
ROOF
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
ROOF PLAN "ER"
BEARING HEIGHT
=BEARING @ 9'-4"
WH
HB
HB
GFI
GFI
GFIGFI
GFI
GFI
GFI
3
33
3
33
3
GFI
TV
TV
T
WP
GFI
WP
GFI
WP
GFI
T
TV
TV
WP
GFI
3
PP
EXH. FAN
VP
DB
STUB OUT FOR
GARAGE DOOR OPENER
A/C DISCONNECT
A/C DISCONNECT
ELECTRIC METER200 AMP PANEL
EXH. FAN
W/ LIGHT
ATTIC
LIGHTGFI
D
D
PRE-WIRE FOR
FAN (TYP.)
PRE-WIRE FOR
FAN (TYP.)
KEYLESS
DPRE-WIRE FOR
FAN (TYP.)
A
OPT.
A
OPT.
A
OPT.
A
OPT.
H H
AA
A
A
A
SD
SCD
SD
SCD
SD
D
PRE-WIRE FOR
FAN (TYP.)
D
A
PRE-WIRE FOR
FAN (TYP.)
A
A
A
A A
A
OPT.
OPT.
OPT.
OPT.
VP
J
ELECTRICAL NOTES:
ALL OUTLETS IN WET AREAS AND ALL
ALL ELECTRIC, ELECTRICAL EQUIPMENT AND APPLIANCES TO BE SET AT
OR ABOVE BASE FLOOD ELEVATIONS PLUS 1'-0" FREEBOARD.
ARC-FAULT CIRCUIT-INTERRUPTERS AND TAMPER
RESISTANT RECEPTACLES SHALL BE INSTALLED
INSTALL PHONE AND T.V PER CONTRACT.
IN DWELLING UNITS PER N.E.C 210.12 AND 406.11
EXTERIOR OUTLETS TO BE GFI'S.
NOTE: NOT ALL SYMBOLS ARE USED FOR THIS
PROJECT.
SURFACE MOUNTED CEILING LIGHT
TELEVISION RECEPTION OUTLET
AC/DC SMOKE DETECTOR
TO BE INTERCONNECTED
WALL MTD. BRACKET LIGHT
DIMMER SWITCH
3 WAY SWITCH
SINGLE POLE SWITCH
TELEPHONE OUTLET
MOTION SENSOR SWITCH
A/C DISCONNECT
DUPLEX FLOOD LIGHT
TRACK MTD. LIGHTS
EXHAUST FAN
PUSH BUTTON (PB) / DOOR BELL (DB)
FLUSH MOUNTED LIGHT
1/2 SWITCHED DUPLEX OUTLET
DUPLEX RECEPTACLE OUTLET
4-PLEX RECEPTACLE OUTLET
220 V RECEPTACLE OUTLET
SINGLE RECEPTACLE OUTLET
DUPLEX RECEPTACLE AT ELEV. A.F.F.
ELECTRICAL PANEL
ELECTRICAL METER
120 V JUNCTION BOX
DUPLEX RECEPTACLE - ABOVE COUNTER
3
D
SD
TV
ELECTRICAL LEGEND
2' UNDER COUNTER LIGHT
4' FLUORESCENT LIGHT
INTERCOMIC
KP
KEYPAD
ANY RESIDENT HAVING A FOSSIL-BURNING
HEATER OR APPLIANCE, A FIREPLACE, OR
AN ATTACHED GARAGE SHALL HAVE AN
OPERATIONAL CARBON MONOXIDE ALARM
INSTALLED WITHIN 10 FEET OF EACH
ROOM USED FOR SLEEPING PERPOSES.
PER RULE 9B-3.04.72
SD (SMOKE DETECTOR)
SCD (CARBON MONOXIDE/ SMOKE
DETECTOR)
AFF
MS
INSTALL ALL ELECTRICAL PER NEC 2014
SCD
T
200 AMP ELECTRICAL RISER DIAGRAM
200 AMP
PANELM
(2) 4/0 AL & (1) 1/0 AL
OR CU EQUIVALENT
#6 CU MIN. TO (2) GROUND RODS,
AT LEAST 6FT APART.
POWER CO.
ELECTRICAL PLAN 1543
200 AMP SERVICE
TAG
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
QUANTITY PRODUCT
(11)
(1)
(3)
(8)
(2)
(1)
(X)
(2)
(X)
(1)
(1)
(X)
(X)
(X)
(X)
(X)
(X)
(FLUSH MOUNTED LT)
(VAPORS)
(PENDANT LIGHT
(10" MUSHROOMS)
(24" 3 LT)
(36" 4 LT)
(NOT USED)
(COACH LIGHTS)
(COACH LIGHTS)
(J BOX)
(4' FLUORESCENT)
(2' FLUORESCENT)
(5LT CHANDELIER)
(3 LT)
(PENDANT/ NOOK)
(X)
(X)
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-5 ER
ELECTRICAL
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
ELECTRICAL PLAN "ER"
RESIDENTIAL SPECIFICATIONS
1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT
THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL
REPORT ALL DISCREPENCIES BETWEEN THE DRAWINGS AND EXISTING
CONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.
2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK
ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,
HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO
ATTACH AND ACCOMMODATE OTHER WORK.
3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED
TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR
SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT
DETAIL IS SHOWN.
4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE
FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000
PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO
THE DESIGNER PRIOR TO COMMENCING WORK.
5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH JOB
SPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL,
PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR
SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON
STRUCTURAL DRAWINGS.
6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE
ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERS
SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITY
AND EQUIVALENT STRENGTH PRODUCT.
ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING
NAILS, SHALL BE HOT MOPED DIPPED GALVANIZED OR STAINLESS STEEL
CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES,
WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS
AND CONNECTORS AS SPECIFIED HEREIN.
7. TREATED WOOD REQUIREMENTS:-
ALL TREATED WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,
OR NATURALLY RESISTANT TO DECAY.
ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, OR
PRESSURE TREATED.
8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER
THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILTY
TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF
THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE
NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.
9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.
SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5
10. LANAI CEILINGS & COVERED ENTRY CEILINGS
1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"
EXTERIOR GYP. BOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALL
SCREWS @ 6" O.C. EDGE AND FIELD.
GENERAL NOTES
1
ROOF SHEATHING
SHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.
INSTALL PANELS WITH LONG DIMENSION PLACED PERPENDICULAR TO TRUSSES.
A 1/8" SPACE BETWEEN ADJACENT SHEETS SHALL BE MAINTAINED . INSTALL "H"
CLIPS AT UNSUPPORTED PANEL EDGES. THE ROOF SHEATHING SHALL BE NAILED WITH
8d RING SHANK NAILS @ 4" O.C. EDGE AND 6" O.C. FIELD. ENSURE THAT ALL NAILS
PENETRATE THE TOP CHORD OF THE TRUSSES WITHOUT SPLITTING. RING SHANK NAILS
PER R803.2.3.1 - 0.113" NOMINAL SHANK DIAMETER, RING DIAMETER OF 0.012"
OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL
ROUND HEAD, 2" NAIL LENGTH.
FLASHING
FLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL 0.0179" THICK,
26 GAUGE AZ50 ALUM ZINC, OR GALVANIZED STEEL 0.0179" THICK, 26 GAUGE
ZINC COATED G90. FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIP
SYSTEM ROOF SHEATHING MANUFACTURES PUBLISHED REQUIREMENTS. ALL
FLASHING AND INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).
DRIP EDGE
DRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLES ROOFS,
LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A MINIMUM
OF 1/2" BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINMUM
OF 2". DRIP EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE SHALL
BE A MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE.
GENERAL ROOF ASSEMBLY
2
INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE
LAYER APPLICATION UNDER TILE ROOF.
THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLY
WITH THE PROVISIONS OF R905.3 F.B.C.
MARKING: EACH ROOF TILE SHALL HAVE A PERMANENT
MANUFACTURER'S IDENTIFICATION MARK.
APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTEN
APPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALL
INCLUDED BUT NOT BE LIMITED TO THE FOLLLOWING:
1. TILE PLACEMENT AND SPACING,
2. ATTACHMENT SYSTEM NECESSARY TO COMPLY
WITH CURRENT WIND CODE,
A. AMOUNT AND PLACEMENT OF MORTART
B. AMOUNT AND PLACEMENT OF ADHESIVE
C. TYPE, NUMBER, SIZE AND LENGTH OF FASTENERS AND CLIPS.
3. UNDERLAYMENT
4. SLOPE REQUIREMENT.
CLAY AND CONCRETE ROOF TILE SPECS
4
SHINGLES
15# FELT SHALL BE INSTALLED UNDER ASPHALT SHINGLES. ALL
ASPHALT SHINGLES SHALL HAVE SELD-SEALING STRIPS OR BE
INTERLOCKING AND COMPLY WITH ASTM D 225 OR D 3462, AND
SHALL BE SECURED TO THE ROOF WITH NO LESS THAN 6
FASTENERS PER SHINGLE STRIP, OR A MINIMUM OF 2 FASTENERS
PER SHNGLE TAB, AND SHALL IN NO CASSE BE FASTENED WITH
LESS FASTENERS THAN THAT REQUIRED BY THE MANUFACTURE.
INSTALLATION SHALL COMPLY WITH MANUFACTURES REQUIREMENTS
FOR INSTALLATION IN THE GIVEN FLORIDA WIND ZONE, AS
DETERMINED BY ASTM D 3161.
FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL COMPLY WITH ASTM F
1667, AND SHALL BE MADE WITH GALVANIZED STEEL, STAINLESS
STEEL OR ALUMINUM WITH A MINIMUM SHANK SIZE OF 12 GAUGE
(0.105") WITH A MINIMUM 3/8" DIAMETER HEAD SHANK AND SHALL
BE A LENGTH TO PENTRATE THE SHEATHING
THE NAIL COMPONENT OF PLASTIC CAP NAILS SHALL MEET OR EXCEED
THE REQUIREMENTS OF ASTM A 641, CLASS 1, OR EQUAL, AND
SHALL BE CORROSION RESTITANT BY ELECTRO GALVANIZATION,
MECHANICAL GALVANIZATION, HOT DIPPED GALVANIZATION OR
SHALL BE MADE OF STAINLESS STEEL, NON-FERROUS METAL
ASPHALT SHINGLE ROOF SPEC'S
3
A.P.A. RATED STURDI-FLOOR, EXPOSURE 1, TONGUE & GROOVE EDGES
SPAN RATING 48/24 OR BETTER, GLUED AND NAILED
FLOOR SHEATHNG AT 2ND FLOOR
5
R310.2.1 MINMUM OPENING AREA- ALL EMERGENCY ESCAPE AND RESCUE
OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF
5.7 SQUARE FEET (0.530 m2).
EXCEPTION- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET
CLEAR OPENING OF 5 SQUARE FEET (0.465 m2).
R310.2.1 MINMUM OPENING HEIGHT- THE MINIMUM NET CLEAR OPENING
HEIGHT SHALL BE 24 INCHES (610mm).
R310.2.1 MINMUM OPENING WIDTH- THE MINIMUM NET CLEAR OPENING
WIDTH SHALL BE 20 INCHES (508mm).
R310.1.1 OPERATIONAL CONSTRAINTS- EMERGENCY ESCAPE AND RESCUE
OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM
WITHOUT THE USE OF KEYS OR TOOLS.
R310.2.3 WINDOW WELLS- THE MINIMUM HORIZONTAL AREA OF THE WINDOW
WELL SHALL BE 9 SQUARE FEET (0.84 m2), WITH A MINIMUM HORIZONTAL
PROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOW
WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE
FULLY OPENED.
MINIMUM EGRESS WINDOW DETAIL
1'-8" MIN.
2'-0
" M
IN.
3'-8
" M
AX.
FINISH FLOOR
5.7 SQ. FT.
CLEAR OPENING
R703.4 - WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED BY THE WINDOW
OR DOOR MANUFACTURER OR BY THE FLASHING MANUFACTURER, "PAN FLASHING" SHALL BE
INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL
BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE
EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.
OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OF PROTECTION AT THE
HEAD AND SIDES.
"PAN FLASHING" IS A GENERIC TERM THAT USED TO REFER TO "METAL PAN FLASHING".
HOWEVER MANY MODERN MATERIALS HAVE BEEN DEVELOPED FOR THE SAME FUNCTION
SUCH AS:
- FLEXIBLE PEEL AND STICK FLASHING MEMBRANE
-FLUID APPLIED FLASHING
FOR SUCH PRODUCTS FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS
FOR IN-DEPTH FLASHING INSTRUCTIONS, REFER TO THE FOLLOWING PUBLICATIONS:
FMA/AAMA 100
FMA/AAMA 200
FMA/WDMA 250
FMA/AAMA/WDMA 300
INSTALL "PAN" FLASHING AT THE WINDOW SILL
OPENING FOR WINDOW OR DOOR
WHERE "PAN" FLASHING IS
USED AT THE SILL, ALSO
INCORPORATE FLASHING
OR PROTECTION AT THE
HEAD AND SIDES
THE FLASHING INSTRUCTIONS FROM THE WINDOW/ DOOR MFR., OR THE FLASHING MFR.,
SHALL SUPERCEDE THIS DETAIL
PAN FLASHING PER R703.4
SCALE: N.T.S.
WALL SHEATHING
WITH HOUSE WRAP
OR ZIP SYSTEM
WALL SHEATHING
PAPER BACK
METAL LATH
MID WALL
WEEP SCREED
OVER FELT STRIP
MASONRY NAIL
6" WIDE FELT
MASONRY WALL
WOOD FRAMING EITHER
FLOOR TRUSS OR GABLE
END TRUSS
FELT AND
WEEP SCREED
WO
OD F
RAM
EM
ASO
NRY W
ALL
CORNER OF
BUILDING
CORNER BEAD
MITER OUT CORNER
BEAD AT MID WALL
WEEP SCREED
CAULK CENTER JOINT
IN MID WALL WEEP
SCREED 2" IN EA.
DIRECTION AT CORNER
CORNER OF
BUILDING
FULLY EMBED BACK FACE
OF WEEP SCREED IN
CAULK. LET OOZE OUT AT
CORNER AND SCREED 2"
MIN. WIDTH
WIRE LATH
WITH FELT
OVER FRAME
WALL
EXPANSION JOINT
EXPANSION JOINT OVER
WIRE LATH
DECO. TEXTURE FINISH
OVER WIRE LATH
WO
OD F
RAM
EM
ASO
NRY W
ALL
MASONRY WALLMASONRY WALL
DECO. TEXTURE FINISH
OVER WIRE LATH
EXPANSION JOINT
MASONRY WALL
EXPANSION JOINT
AMICO M-TYPE
CONTROL JOINT
AMCJM-780 OR
APPROVED EQUAL
OVER LATH (CUT
LATH BEHIND
CONTROL JOINT 1/4"
MIN. GAP) LOCATE
OVER STUD ONLY
AND PER NOTE 1
*
*NOTE 1:(AT WOOD
FRAME ONLY)
MAX OF 144 SQ. FT.
BETWEEN CONTROL
JOINTS. NOT GREATER
THAN 18'-0" O.C. MAX
AREA RATIO OF
CONTROL JOINTS-2-2/1 TO 1
WIRE THE CONTROL
JOINT TO LATH WITH
18 GA. GALVANIZED
WIRE AT 7' O.C. MAX.
WIRE LATH
OVER FELT
FELT PAPER
FRAME WALL
FELT STRIP
WIRE LATH OVER
MID WALL
WEEP SCREED
OVER FELT STRIPMID WALL
WEEP SCREED
OVER FELT STRIP
MITER OVER SCREED
FELT STRIP
OVER BLOCK WALL
BUILDING
MASONRY WALL
MID WALL WEEP SCREED DETAIL
WEEP SCREED DETAILINSTALL AT ALL EXTERIOR WALL LOCATIONS WHERE
WOOD STUD FRAMING IS ABOVE MASONRY WALLS.
GABLE WALL ROOF
EXTERIOR
ATTICATTICEXTERIOR
HOUSE WRAP
EXTERIOR PLYWOOD W/
RADIANT BARRIER ON
ATTIC SIDE
EXTERIOR STUD
WALL OR TRUSS
RADIANT BARRIER
GLUED TO PLYWOOD
TOP CHORD
RADIANT BARRIER: SCALE: N.T.S.
NOTE: EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVE
RADIANT BARRIER AND HOUSE WRAP.
8"X8"X16" CONC. BLOCK
CONCRETE FOOTING SEE
FOUNDATION PLAN FOR
SIZE AND REINFORCING.
PRECAST CONCRETE SILL 1/2" DRYWALL W/ TEXTURED WALLS
WOOD BASE
1X2 P.T. FURRING STRIPS @ 24" O.C.
W/ INSULATION (MIN. R4.1)
4" CONC. SLAB ON 6 MIL.
VISQUEEN VAPOR BARRIER ON
MECHANICALLY COMPACTED FILL
@ 95%.
DECO. CEMENT FINISH
PER ASTM C-926
SILL SET IN MORTAR
SEE ENERGY CODE FORMS FOR
INSULATION R-VALUES
1X4 P.T. STRIP
VENTED SOFFIT
SHALL MEET R703.1.2.1
SEE TABLE 3 ON S-3
DRYWALL CEILING
PER NOTE 9 IN
TABLE 1 ON A-6
GRADE
PROVIDE TERMITE TREATMENT
WITH "BORA CARE".
SLOPE TO EXTERIOR
ROOF SHEATHING PER SCHEDULE 2/S-3.
AND PER NOTES IN TABLE 2 ON A-6
TILE ROOF PER NOTE 4 ON A-6.
EMBEDDED STRAP AT EACH
TRUSS PER ROOF FRAMING PLAN.
FLASHING AND
DRIP EDGE PER NOTES
IN TABLE 2 ON A-6
WINDOW, SEE SCHEDULE AND PLAN.
PRECAST LINTEL
SEE FRAMING PLAN
WINDOW BUCKS SEE TABLE 2 ON A-6
1X4 P.T. BUCK W. BED OF
CONTINUOUS CAULK UNDER
PROVIDE VENTILATION
PER R806.1
8"X8" CONTINUOUS
BOND BEAM W/
1 #5, GROUT SOLID
WOOD TRUSSES @ 24" O.C. (TYPICAL)
DESIGNED BY DELEGATED TRUSS ENGINEER.
2X6 MIN. SUB FASCIA
4"
MIN
.
12"
MIN
.D
W
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
A-6
SECTIONS
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
WH
HB
HB
PROVIDE 1/4" WATER
LINE @ REF SPACE
FOR ICE MAKER
4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #
10/10 W.W.M. REINFORCING OVER 6
MILL VISQUEEN BARRIER ON
MECHANICALLY COMPACTED FILL @ 95%.
THE FINISH FLOOR SLAB SHALL BE SET
ABOVE BASE FLOOD ELEVATION PER FEMA
FLOOD MAP PLUS 1'-0" FREEBOARD PER
FBCR R322.2.1. SEE SITE PLAN BY OTHERS
ELEV. @ 0'-0"
ELEV. @ -0'-(-4")
ELEV. @ -0'-(-4")
ELEV. @ -0'-(-4")
SLO
PE
14'-11" 4'-2" 10'-11"
4'-3
1/2
"2
'-6
"1
4'-2
"
24'-4" 3'-6" 2'-2"
1'-1 1/2" 3'-5" 3 1/2" 20'-2" 5'-0"
AHU
1'-4
"5
'-8
"
15
'-5
"8
'-1
0"
44
'-9
"7
'-0
"
1'-4" 13'-2" 15'-6"
30'-0"
76
'-0
"
1'-4" 9'-4" 8" 18'-8"
30'-0"
6" X 12" RECESS
F6AF3
F3
F3
F3
P
PAVERS BY OTHERS
P
P
P
F3 W
/ C
URB
F3 W
/ CU
RB
16'-0" X 8'-0" O.H.G.D.
INSTALL 1-3/8" THICK SOLID WOOD
DOOR BETWEEN LIVING AND
GARAGE PER FBC R302.5.1
INDICATES (1) #5 VERTICAL BAR
IN GROUTED CELL. LAP 25" W/ #
5 DOWEL OUT OF SLAB W/ 7"
HOOK INTO TOP OF BOND BEAM
@ 48" O.C. MAX.
8F8-1B SET AT GARAGE DOOR HEAD HEIGHT ADD
COURSING AS REQUIRED TO 8"X8" BOND BEAM W/
(1) #5 BAR. TOP @ 9'-4" ADD #5 VERT @ 48" O.C.
GROUT ALL SOLID.
1'-4" 16'-0" 1'-4"
PAVERS BY OTHERS
F3
F3
SET A/C PAD ABOVE FLOOD
ELEVATION W/ 1'-0" FREEBOARD
PER FBC 322.2.1
REF.
SPAC
E
RANG
E
DBL. SINK
30'-0"
5'-4" 9'-9" 4'-0" 8'-8 1/2" 2'-2 1/2"
4'-0
"3
'-6
"1
'-4
"
76
'-0
"
20
'-8
"6
'-1
0 1
/2"
1'-3
"7
'-5
"3
9'-9
1/2
"
5'-0" TUB/SHWR
13
'-0
"4
'-0
1/2
"1
'-0
1/2
"3
'-1
"
TILE SHOWER
RECESS 3 1/2"
WASHER DRYER
A
A
AA
LOWEST POINT OF GARAGE SHALL BE SET ABOVE
BASE FLOOD ELEVATION PER FEMA FLOOD MAP
16" SQUARE MASONRY COLUMN
W/ 4#5 VERT. & #3 TIES @ 8"
O.C.
16" SQUARE MASONRY COLUMN
W/ 4#5 VERT. & #3 TIES @ 8"
O.C.
PROVIDE SAWCUT
SLAB PER 5/S-4
F3
A
F3
#5 VERTICAL @ DOT LOCATION (48"
O.C. MAX) IN GROUTED CELL W/ 7"
HOOK INTO BOND BEAM
F3
A
SET W/H ABOVE FLOOD W/ 1'-0"
FREEBOARD PER FBCR R322.2.1
4'-6
"1
'-6
"5
'-9
1/2
"
STANDARD SGD RECESS 1-1/2".
IMPACT GLASS SGD RECESS 2-1/2".
PROVIDE TERMITE TREATMENT
WITH "BORA CARE"
DW
1'-8
"
FIN. GRADE
#5 DOWEL WITH
7" HOOK, EMBED
5" MIN.
2 #5 CONT. W/
3" CLEAR COVER.
1'-0"
1'-0"
MIN
.
2'-1
"
1'-8
"
FIN. GRADE
#5 DOWEL WITH
7" HOOK, EMBED
5" MIN. BELOW
GARAGE FLOOR
2 #5 CONT. W/
3" CLEAR COVER.1'-0"
1'-0"
MIN
.
7 5/8"
.
VARIES WITH
SLOPE OF FLOOR
CURB IS OPTIONAL & NOT INCLUDED
IN FOOTING DIMENSIONS
2'-1
"
3" CLEAR COVER2 #5
8"
1'-4"
3" CLEAR COVER(1)- #5
8"
8"
8"X8" CONC. RIBBON
W/ 1 #5 ROD CONT.
1" 3"
8"
8"
PAVERSMORTAR
FOUNDATION PLAN
PLAN NOTES:
1. TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0"
2. "F#" DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET.
3. PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM FOOTING
TO BOND BEAM.
4. ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES MAY
EXTEND BEYOND FACE OF WALL.
5. FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/
DOOR SUPPLIER.
6. PROVIDE PRESSURE TREATED BUCKS AT WINDOWS/ DOORS PER DETAIL 7/S-3.
SCALE: 1/4" = 1'-0"
TYPE LENGTH WIDTH DEPTH
2'-6" 2'-6"
3'-0"3'-0"
3'-6"3'-6"
4'-0"4'-0"
5'-0"5'-0"
A
B
C
D
E
1'-0"
1'-0"
1'-0"
1'-2"
1'-2"
3-#5 3-#5
4-#5 4-#5
4-#5 4-#5
5-#5 5-#5
6-#5 6-#5
-
-
-
-
-
REMARKSLONG WAY SHORT WAY
BOTTOM REINF.
PAD FOOTING SCHEDULE
US
ED
TYPE LENGTH WIDTH DEPTH
CONT. 1'-4"
1'-8"
1'-0"
1'-4"
1'-4"
F1
F2
F3
F4
F5
1'-8"
1'-0"
1'-0"
2-#5
SHAPE
WALL FOOTING SCHEDULE
US
ED
BOTTOM
REINFORCING
F6
F6A
TE
CONT.
CONT.
CONT.
CONT.
CONT.
CONT.
CONT.
1'-4"
0'-8"
0'-8" 0'-8"
0'-8"
1'-8"
0'-10"
0'-8"
2-#5
2-#5
2-#5
2-#5
2-#5
1-#5
1-#5
ADD CURB TO
GARAGE, SEE
DETAIL
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
S-1 ER
FOUNDATION PLAN
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
FOUNDATION PLAN "ER"
1/2" = 1'-0"
"F3" FOOTING
1/2" = 1'-0"
"F3" WITH CURB AT GARAGE
1/2" = 1'-0"
"F6" STEP DOWN
1/2" = 1'-0"
"F6A" STEP DOWN
1/2" = 1'-0"
"P" PAVERS DETAIL ENTRY/ LANAI
WH
HB
HB
V1
V2
V3
A1
J4
J4J4
J6A
J6A
J6A
J2
J2 J2
CJ1
2CJ1
2
J4
J6A
J2
A2
A3
A4
A6
A7
A3
A4
A5
B1
B2
B3
J4
J2
J6
J6
CJ9
J4
J2
EJ8
EJ7
BATH #1
STUDY/ DEN
GARAGE
HIP
VAL
LEY
HIP
RID
GE
RID
GE
HIP
HIP
LANAI
BEDROOM #1
KITCHEN
NOOK W.I.C.
BEDROOM #2
GREAT ROOM
BATH #2
LAUNDRY
GARAGE
FOYER
ENTRY22" X36"
ATTIC ACCESS
SET BOTTOM OF 8F8-1B LINTEL
AT GARAGE DOOR HEAD
HEIGHT,ADD COURSING TO TOP
OF WALL @ 9'-4" W/ 8X8 BOND
BEAM W/ (1) #5 GROUT SOLID.
8F16-1B/1T
8F8-1B
EXTERIOR CEILING PER
SCHEDULE 2/S-3
EXTERIOR CEILING PER
SCHEDULE 2/S-3
8F1
6-1
B/1
T
8F8
-0B
8F8
-0B
8F8-0B
8F8-0B
8F8-0B
8F16-1B/1T
8F1
6-1
B/1
T
8F8-0B
8F8
-0B
8F8
-0B
6" WALL
6" WALL
GARAGE SHALL BE SEPARATED FROM THE
RESIDENCE & ATTIC BY NOT LESS THAN 1/2"
GYPSUM BOARD APPLIED TO THE GARAGE SIDE.
GARAGES BENEATH HABITABLE ROOMS SHALL BE
SEPARATED WITH NOT LESS THAN 5/8" TYPE "X"
GYPSUM BOARD OR EQUIVALENT. WHERE THE
SEPARATION IS A FLOOR-CEILING ASSEMBLY THE
STRUCTURE SUPPORTING THE SEPARATION SHALL
ALSO BE PROTECTED BY NOT LESS THAN 1/2"
GYPSUM BOARD OR EQUIVALENT.
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
9'-4" FLAT CEILING
#5 CORNER BAR IN BOND
BEAM PER 8/S-3
(+33.5 -44.8)
(+29.4 -33.3)
(+3
3.5
-3
6.3
)(+
33.5
-3
6.3
)(+
33.5
-3
6.3
)
(+3
3.5
-3
6.3
)
(+33.5 -36.3)
(+33.5 -36.3)
(+28.2 -31.5)
WHERE ROOF SHEATHING CONTACTS ONLY
THE EDGE OF ROOF TRUSSES, INSTALL
BEVELLED BLOCKING PER DETAIL THIS SHEET
(DR HORTON COMPANY REQUIRMENT)
SEE DETAIL 9/S-3 WHERE
LINTEL AT LANAI/ENTRY
INTERSECTS MAIN, WALL,
TYPICAL
EMBED META16 AT ALL
TRUSSES, EXCEPT AS
NOTED AT GIRDERS
1-META16 ALL
TRUSSES EXCEPT AS
NOTED AT GIRDERS(+33.5, -36.3) WINID PRESSURES PER
ASCE7-10, 160 MPH EXPOSURE C, AND
CONVERTED TO ALLOWABLE STRESS
DESIGN PRESSURES USING 06.W LOAD
FACTOR. (Vasd=124 MPH, RISK CAT II,
ENCLOSED, kd=0.85, H-15'0)
8X8 CONTINUOUS MASONRY
BOND BEAM AT TOP OF WALL
W/ 1 #5 BAR. PROVIDE CORNER
BARS PER 8/S-3
CORNER BARS IN BOND
BEAM PER DETAIL 8/S-3
1-META16
@ A1
1-HETA20
@ A1
1-META16
@ A1
GABLE END BRACING
PER 12/S-3
META16 @ 32" O.C.
@ INSIDE FACE OF
GABLE
#5 VERTICAL @ DOT LOCATION (48"
O.C. MAX) IN GROUTED CELL W/ 7"
HOOK INTO BOND BEAM
12
S-3
WALL ABOVE WITH BOND
BEAM AT TOP
#5 VERTICAL, ABOVE
LINTEL ONLY WHERE
NOTED ON PLAN
'1B' DENOTES 1#5 BOTTOM
WITH 7" HOOK EACH END OR
EXTEND 24" BEYOND OPENING.
'0B' DENOTES "NO REBAR"
8" PRECAST LINTEL
GR
OU
T S
OLID
1'-4"
GR
OU
TE
D
1#5 TOP
1#5 BOTTOM
8F8-1B
8F8-0B
8F16-1B/1T
PRECAST LINTEL SCHEDULE
AT SWING DOORS, USE 2" RECESS STYLE
LINTEL IF NEEDED FOR ROUGH OPENING.
LINTELS BEAR 4" MIN. EACH END
ROOF SHEATHING
8d RING SHANK @
6" O.C.
16d NAILS
@ 8" O.C.
2" X () BLOCKING W/
BEVEL CUT TOP
ROOF TRUSS
BEVELLED BLOCKING DETAIL
PLAN NOTES:
1. ROOF TRUSS BEARING ELEVATION VARIES, SEE
LEGEND.
2. ROOF FRAMING SHALL BE WOOD TRUSSES DESIGNED
BYA DELEGATED TRUSS ENGINEER PER DESIGN
CRITERIA ON SHEET S-3.
3. PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS
SHEET.
4. FOR NAILING OF ROOF DECK, SEE 1 AND 2 ON S-3.
5. 8F8-1B etc., DENOTES PRECAST LINTEL ABOVE
DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET.
6. AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND
BEAM W/ 1 #5 CONTINUOUS, SEE DETAIL 11/S-3.
TRUSS STRAPPING TO MASONRY
MAX TRUSS UPLIFT
@ 24" OC (LBS)CONNECTOR FASTENER
1450
1810
2120
1875 (1 PLY)
1795 (2 PLY)
2365 (2 PLY)
2365 (2 PLY)
3965/SYP 3330/SPF
4235/SYP 3640/SPF
4670/SYP 4015/SPF
5445/SYP 5360/SPF
10690/SYP 10690/SPF
10790/SYP 10790/SPF
(1) META16 TO 40
(1) HETA16 TO 40
(1) HHETA16 TO 40
(2) META16 TO 40
(2) META16 TO 40
(2) HETA16 TO 40
(2) HHETA12 TO 40
MGT (2 PLY)
HTT4
HTT5
HTT5KT
(1)HGT - 2
(1)HGT - 3
(8) 0.148x11/2 ", EMBED 4"
(9) 0.148x11/2", EMBED 4"
(10) 0.148x11/2", EMBED 4"
(10) 0.148x11/2", EMBED 4"
(14) 0.162x31/2", EMBED 4"
(12) 0.162x31/2", EMBED 4"
(12) 0.162x,31/2" EMBED 4"
(22) 0148x3" ATR, EPOXY 12"
(18) 0.162x21/2", 5/8" ATR, EPOXY 12"
(26) 0.148x3", 5/8", ATR, EPOXY 12"
(26) SD#10x21/2, 5/8," ATR, EPOXY
(26) 0.148x3" TO GIRDER
(2) 3/4" Ø ATR, EPOXY 12"
(16) 0.148x3" TO GIRGER,
(2) 3/4" Ø ATR, EPOXY 12"
INSTALL
META16 AT
ALL
TRUSSES
TO 1450 lb
UPLIFT. FOR
HIGHER
UPLIFTS,
SEE NOTES
ON PLAN.
NOTES:
1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED
ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE AND
SUITABLE FOR THE GEOMETRY. EMBED STRAP ON -C OF WALL.
2. CONNECTORS ARE SIMPSON STRUCTURAL CONNECTORS. ALL CONNECTORS SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTUCTIONS.
SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE ENGINEER OF RECORD.
3. WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL RETROFIT STRAP PER
10/S-3.
SIMPSON CATALOG C-C- 2019
TRUSS STRAPPING TO STUDWALL/ WOOD BEAM
MAX TRUSS UPLIFT
@ 24" OC (LBS)CONNECTOR FASTENER
850
1700
2550
1125
2250
3375
4500
(1)MTS16 TO 20
(2) MTS16 TO 20
(3) MTS16 T0 20
(1) HTS20 TO 30
(2) HTS20 TO 30
(3) HTS20 TO 30
(4) HTS20 TO 30
(14) 10dx1-1/2"
(14) 10dx1-1/2"
(14) 10dx1-1/2"
(24) 10dx1-1/2"
(24) 10dx1-1/2"
(24) 10dx1-1/2"
(24) 10dx1-1/2"
INSTALL AT ALL
TRUSSES TO
840 lb UPLIFT.
FOR HIGHER
UPLIFTS, SEE
NOTES ON
PLAN.
NOTES:
1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING
POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED
TRUSS DESIGN PACKAGE.
2. CONNECTORS ARE SIMPSON SRTONG TIE. ALL CONNECTORS SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTUCTIONS.
SIMPSON CATALOG C-C- 2019
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PLAN:
REVISED:
DESIGN IN ACCORDANCE WITH THE RESIDENTIAL
FLORIDA BUILDING CODE 2017 - 6TH EDITION
As indicated
L:\0
-New D
ata
\1-M
ASTER 2
019\2
019-B
UIL
DERS\D
R H
ORTO
N
2019\S
UBD
IVIS
IONS\S
EASO
NS B
ONIT
A 5
0's\1
1775 L
OT 2
24 1
543 E
R\R
EVIT
\11775 1
543
ER.r
vt
S-2 ER
ROOF FRAMING PLAN
15
43
MO
DEL
JWC
JSL
08/03/20
LOT:
22
4
SUBD
IVIS
ION:
SEASO
NS B
ONIT
A 4
0s
AD
DRS:
28
359
CAPTIV
A S
HELL
LO
OP
D.R
.H.
#:
57
92
10
237
GC
D J
OB #
11
775
1/4" = 1'-0"
ROOF FRAMING PLAN "ER"
BEARING HEIGHT
=BEARING @ 9'-4"
TRUSS BEARING CONDITIONS AND STRAPPING
IS BASED ON TRUSS LAYOUT PREPARED BY
SCOSTA JOB# 44118CANT DATED: 09/12/18
REVISED: 02/13/20
” ” ”
” ”
”