Products Solutions Services Application / Function Overview Technical data Dimensions Electrical connection Price table Contact Go to shop Technical Datasheet TD 00053E/24/EN/01.13 Hygienic process connections, surface finishing R a ≤ 0.8 µm PC programmable transmitter with 4 to 20 mA output or Pt100 sensor Fast response times without reduced tip M12×1 plug-in connector with IP 66 Compact thermometer from stainless steel Complete product information: www.e-direct.us/tmr35 Specs at a glance: Temperature range: -50 to +200 °C (-58 to 392 °F) Accuracy: < 0.08 %, Pt100 class A Immersion length (diameter): 40 to 600 mm (Ø 6 mm) (1.6 to 23.6” (Ø 0.24)) Sensor response time: < 1.0 s (T 50 ), < 2.0 s (T 90 ) Hygienic compact thermometer with M12 connector, Pt100 or 4 to 20 mA Easytemp TMR35 $ 130.00
Transcript
Page 1: TMR35

Products Solutions Services

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Technical DatasheetTD 00053E/24/EN/01.13

•Hygienic process connections, surface finishing Ra ≤ 0.8 µm

• PC programmable transmitter with 4 to 20 mA output or Pt100 sensor

• Fast response times without reduced tip

•M12×1 plug-in connector with IP 66• Compact thermometer from

stainless steel

Complete product information:www.e-direct.us/tmr35

Specs at a glance:

•Temperature range: -50 to +200 °C (-58 to 392 °F)

•Accuracy: < 0.08 %, Pt100 class A

•Immersion length (diameter): 40 to 600 mm (Ø 6 mm) (1.6 to 23.6” (Ø 0.24))

•Sensor response time: < 1.0 s (T50), < 2.0 s (T90)

Hygienic compact thermometer with M12 connector, Pt100 or 4 to 20 mA

EasytempTMR35

$ 130.00

Page 2: TMR35

EasytempTMR35 2

Overview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Application / Function

Application Characterised by simplicity and compact construction, the Easytemp TMR35 is available with a range of hygienic process connections. It offers good accuracy and response times and has been specifically designed for hygienic applications with 3-A certification.

Function The compact thermometer consists of a Pt100 class A sensor, (optional) transducer and housing with hygienic process connection. The built-in electronics can be programmed using a PC and TXU10-BA configuration kit to convert the Pt100 input signal into a temperature linear 4 to 20 mA signal.

Installationinstructions

Pipe installation a) At angle sections, against the

direction of flowb) In smaller pipes, turned

against the direction of flowc) Perpendicular to the direction

of flow

L = Insertion length

b)a)

c)

L

Page 3: TMR35

EasytempTMR35 3

Application / FunctionOverview

Electrical connection Price table ContactGo to shop

DimensionsTechnical data

Technicaldata Dimensions(ininches)

SensorSensing element 1×Pt100Tolerance Class A according to IEC 751Process temperature -50 to +200 °CMaterial 316LSurface finishing Ra ≤ 0.8 µmSensor diameter 6 mm (0.24")Sensor length 40 to 600 mm selectable (please specify)Response time T50 = ≤ 1.0 s; T90 = ≤ 2.0 sMax. pressure 100 bar / 1500 psi (at 100 mm / 3.94" and

20 °C / 68 °F, depending on process connection)

Process connectionVersion Conical metal-to-metal connection, with G

½"; TRI-CLAMP® flange 1" 1-½", ISO 2852 DN 25/38; Dairy connection DIN 11851 DN 25; Varivent® Ø 68 mm for DN 32/125

Transmitter housingDegree of protection IP 66Electrical connection M12×1-plug-in connectorMaterial 304

Output characteristicsOutput signal 4 to 20 mA, 20 to 4 mA / Pt100Signal on alarm Sensor break; Sensor short-circuit: ≤ 3.6 mA

or ≥ 21.0 mALoad Max. (Upower supply -10 V)/0.023 AInd. current requirem. ≤ 3.5 mACurrent limitation ≤ 23 mASwitch-on delay 2 s

Power supplySupply voltage Ub = 10 to 35 V DCResidual ripple Permitted residual ripple Uss ≤ 3 V at Ub ≥ 13

V, fmax = 1 kHz

AccuracyTransmitter response time

1 s

Reference operating conditions

0 °C (32 °F) (ice bath)

Measuring error 0.1 K (0.18 °F) or 0.08 %Influence of supply voltage

≤ ±0.01 %/V deviation from 24 V

Influence of ambient temperature (temperature drift)

Td = ±(15 ppm / K × (full scale value of measuring range + 200) + 50 ppm/K × set measuring range) × ΔθΔθ = deviation of ambient temperature from the reference operating condition

Long-term stability ≤ 0.1 K/year or 0.05 %/yearInfluence of load ≤ ±0.02 %/100 Ω

Operating conditionsAmbient temperature -40 to +85 °C (-40 to 185 °F)Storage temperature -40 to +85 °C (-40 to 185 °F)Climate class As per EN 60 654-1, Class CShock resistance 4 g/2 to 150 Hz as per IEC 60068-2-6EMC According to IEC 61326 Series and NAMUR

NE21

Approvals3A

M12×1

Ø 1.71

DB (CLAMP 1“)

Installation according to operation instructions.

DL (CLAMP 2“)

1.71

0.39

Ø 0.71

Ø 0.24

Ø 1.99Ø 2.22Ø 2.52

Page 4: TMR35

EasytempTMR35 4

Application / FunctionOverview Technical data Dimensions

ContactGo to shopPrice tableElectrical connection

Pricetable

Easytemp TMR35 Order no. Price/pcs. in USDOutput Process Connection Length 1 to 5 6 to 10 11 to 35Pt100, DIN class A, 4-wire

Clamp ISO2852 DN25-38, 1-1½", 316L,3A DIN32676 DN25-40

38 mm (1.57"); 3mm (0,12"); w/o TMR35-A11ADBBA1AAA 148.00 138.00 130.0083 mm (3.27"); 3mm (0,12"); w/o TMR35-A11ADBBB1AAA 148.00 138.00 130.0068 mm (2.68"); 3mm (0,12"); w/o TMR35-A11ADBBC1AAA 148.00 138.00 130.0098 mm (3.86"); 3mm (0,12"); w/o TMR35-A11ADBBD1AAA 148.00 138.00 130.00

CIamp ISO2852 DN40-51, 2", 316L, 3A, DIN32676 DN50

38 mm (1.57"); 3mm (0,12"); w/o TMR35-A11ADLBA1AAA 148.00 138.00 130.0083 mm (3.27"); 3mm (0,12"); w/o TMR35-A11ADLBB1AAA 148.00 138.00 130.0068 mm (2.68"); 3mm (0,12"); w/o TMR35-A11ADLBC1AAA 148.00 138.00 130.0098 mm (3.86"); 3mm (0,12"); w/o TMR35-A11ADLBD1AAA 148.00 138.00 130.00

Accessories Order no. Price/pcs. in USDG1/2 metal to metal weld in adapter 60021387 49.00Configuration kit TXU10 – set-up programme+interface cable for PC with USB-Port. 4 pin plug+ReadWin2000+adapter M12

TXU10-BA 238.00

Cable M12x1 l=5m 51005148 20.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.

Complete product information:www.e-direct.us/tmr35

Moreproductstocompleteyourmeasuringpoint…

Electricalconnection

red

1×Pt100

1×Pt100

white

4

4

3

30 V(4 to 20 mA)

1

110 to 35 V DC(4 to 20 mA)

4 to 20 mA

2

2

red

white

PressuretransmitterCerabar T PMP135

PointlevelswitchLiquiphant T FTL20H

FlowmeasuringsystemProline Promag 10D

Page 5: TMR35

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Contact

E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143

Direct order

Internet www.e-direct.usby phone 888- EH-DIRECT

(343-4732)per Fax 317-535-8498E-Mail [email protected]