+ All Categories
Home > Documents > Tonality Ceramic Facade Brochure

Tonality Ceramic Facade Brochure

Date post: 24-Jul-2016
Category:
Upload: engineered-assemblies
View: 228 times
Download: 1 times
Share this document with a friend
Description:
Tonality Ceramic façade is a unique product with an unprecedented range of colours. The dye-penetrated fired-clay tiles offer user-friendly installation. This installation enables extremely variable designs of joints and maximizes design freedom. CSC # 07 44 23. The Tonality Ceramic Facade Brochure features all colours and finishes available in the Tonality line. For thermally broken facade design using Tonality Ceramic Facade refer to the Engineered Assemblies TcLip & RVRS Design Guide.
42
1 cladding clay tiles Tonality ® The Wave, Denmark, Henning Larsen Architects
Transcript
Page 1: Tonality Ceramic Facade Brochure

1

claddingclay tilesTonality®

The Wave, D

enmark, H

enning Larsen Architects

Page 2: Tonality Ceramic Facade Brochure

2

Natural clay sets the toneTonality tilesNatural fired clay tiles, made from the finest Westerwald clay will give your commercial, public and even residential building a natural terracotta cladding look!With an easy and user friendly installation, different joint options and a wide variety of surfaces and colours, Tonality clay tiles will be an inspiration for everybody!

Easy installation, lift and lock solutionWe offer a comprehensive terracotta rainscreen system featuring lift and lock technology with aluminum vertical profiles, horizontal sub-grits, wall brackets and trim pieces.It is a genius single-skin cladding solution, proven to be stronger than the most traditional systems.

Maggie’s Cancer Caring Centers, United Kingdom – Architect Piers Gough Barham Park, United Kingdom – PRP Architects

Page 3: Tonality Ceramic Facade Brochure

3

Fine surface

Solid

Longlasting

Page 4: Tonality Ceramic Facade Brochure

4

ContentsProduct Overview Preface 5 Ventilated Façade 6 Advantages 10 Colour Chart 12 TONALITY® Adaptive Fixing System 15 Sun Protection 17 Product Overview 19 TONLAITY® Classic 21 TONALITY® Baguettes, Lamelle Tiles & Square-shaped Quadrats 23

System Construction TONALITY® System Sub-Construction Adaptive & Standard Details System on Metal Sub-Construction 25 TONALITY® System Sub-Construction Adaptive System on Wooden Sub-Construction 31 TONALITY® Adaptive System T-Line® 32 TONALITY® Adaptive System Siding® 34

Planning Basics General & Technical Information on & Installation TONALITY® Cladding Tiles 36 Round Walls with Standard Cladding Tiles 41 Special Designs 42

References Engineered Assemblies brilliant buildings 43

Technical status 02/2014All notes, technical and graphic information correspond to the current state of the art and to our experience based on this. The installers described are examples and do not take into consideration the conditions specific to individual cases. The information given and the suitability of the materials for their proposed use must be checked by the purchaser in all cases. We (companies of Etex group) accept no liability. This also applies in respect to misprints and subsequent change of a technical nature.

Page 5: Tonality Ceramic Facade Brochure

5

PrefaceCLAY TILE FAçADE TONALITY®

The clay tile façade TONALITY® extends the product range for suspended back vented facades with an appealing natural material. TONALITY® cladding tiles have represented highest quality, frost resistance and durability for decades now. The range comprises through colored burnt-clay tiles with natural surface texture, cladding tiles with matt and glossy surface finish and durable graffiti protection, as well as color-glazed tiles in a large variety of colors. The sun and privacy protection elements “Lamelle” and “Baguette” are completed by the new square-shaped tile “Quadrat”. Components of the Classic range are also available with smooth, pilaster strip and grooved surfaces. The compatibility of the system consisting of the TONALITY® cladding tile and of the system sub construction allows for fast, time-saving installation.

All cladding tiles of the TONALITY® range are non-combustible (Fire resistance acc. to Building Material Class A1). With formats from 150 x 300 mm up to 400 x 1,600 mm, the range opens up broad possibilities of design and material combinations with fiber cement panels of large format.

The following pages are intended to evoke design ideas, and as a practical guide to construction and realization. Whether it is an office complex, a commercial building or school – the illustrated buildings will convince you with regard to their aesthetic appeal and their economic efficiency. And even in building renovations, the suspended back-vented façade of TONALITY® cladding tiles proves to be a reliable system with favorable building characteristics.

Our qualified façade experts stand ready to give you custom and project-related advice either by phone or on location. We are pleased to assure you of our strong support during the course of all building stages, particularly pertaining to detail planning, invitations of tenders or economical optimization. Take advantage of our knowledge and expertise of future-oriented façade systems. We are open to your ideas.

Page 6: Tonality Ceramic Facade Brochure

6

Ventilated facadeOriginated in Scandinavia centuries ago, the ventilated facade (rainscreen) technique is now very prominent in areas with demanding climatic conditions.In the terracotta rainscreen system, the outer tile deflects rain and sun heat away from the building. The ventilation space allows air to freely circulate behind the tile, creating a well ventilated and comfortable inner building.

VersatilityThe ventilated facade construction principle combines the scalability of curtain wallconstruction with the creative versatility and adaptability offered by traditional buildingtechniques.

Less is moreA ventilated facade system has minimal thickness and weight, yet it offers maximum performance.

HealthyThe ventilated facade construction principle avoids cold bridges, eliminating condensation and mould growth.

Page 7: Tonality Ceramic Facade Brochure

7

Terracotta rainscreen

Ventilation spaceOuter layer

Fixing system

Page 8: Tonality Ceramic Facade Brochure

8

Tonality®

Page 9: Tonality Ceramic Facade Brochure

9

Page 10: Tonality Ceramic Facade Brochure

10

AdvantagesCreativeAvailable in an endless range of colours and sizesPossibility to play with tile formats from 150x300mm up to 600x2000mmProduced in different surfaces: smooth, grooved, pilaster strip & waved version

EconomicalOne layer means less weight & less use of substructureHigh wind pressure resistance due to rear strengthening hanging systemThe time saving “lift & lock” system ensures a fast and precise installation

Maintenance freeFine & smooth surface which ensures no contaminationPermanent “Graffiti Protection” is included in all finishes except for natural Brick Red finish

EcologicalEnvironmental Product DeclarationEnvironmental Managing System DIN EN ISO 14000

Fortinos, Stoney Creek ON – Turner Fleischer Architects

Page 11: Tonality Ceramic Facade Brochure

11

St. George Island, United Kingdom

Design possibilities

Kinderhaus Pertinsel, Austria – Architect Lothar Huber

Page 12: Tonality Ceramic Facade Brochure

12

Colour Chart Tonality®

Available surface options | smooth

Tonality® Siena

70100 Anthracite 70102 Red 70103 Beige 70101 White

Tonality® Travertin

69900 Yellow 69901 Red 69902 Beige 69903 Grey

Available surface options | smooth

grooved one pilaster stripe

Tonality® Natur

70017 Toscana 70002 Beige 70024 Cream light 70015 Pearl grey

70010 Flint grey 70021 Umbra grey *70019 Brick red (natural)

Tonality® Nuance

70020 Brick red (finished surface) 70006 Dark red 70011 Copper red 70009 Bright red

70016 Sand 70004 Cream 70018 White matt 70022 White glossy

70007 Eggshell 70013 Light grey 70008 Bright grey 70014 Middle grey

70005 Dark grey 70001 Anthracite 70025 Black matt 70023 Black glossy

Please note that actual colours may slightly vary in appearance from those shown on the colour chart.*Graffiti Protection is offered on all colours except Tonality Brick Red (Natural)

GRAFFITIPROTECTION

Page 13: Tonality Ceramic Facade Brochure

13

Colour Chart Tonality®

Available surface options | smooth

grooved one pilaster stripe

Tonality® Noblesse Color

70355 – BL1 70356 – BL2 70357 – BL3 70358 – BL4

70380 – GR1 70381 – GR2 70382 – GR3 70383 – GR4

70370 – TU1 70371 – TU2 70372 – TU3

70390 – VI1 70391 – VI2 70392 – VI3

70365 – GE1 70366 – GE2

70375 – OK1 70376 – OK2

70350 – CR1 70351 – CR2 70352 – CR3

70360 – OR1 70361 – OR2

70385 – RO1 70386 – RO2

70340 – BR1 70341 – BR2

Please note that actual colours may slightly vary in appearance from those shown on the colour chart.* Graffiti Protection is offered on all colours.

GRAFFITIPROTECTION

Page 14: Tonality Ceramic Facade Brochure

14

Cladding tile tonality®

TONALITY® cladding tiles have

represented highest quality, frost

resistance and durability for decades

now.

The unique variety of colors with select

surfaces, the outstandingly attractive

joint design, and the consumer

oriented installation constitute the

distinguishing features of the high

quality cladding tiles TONALITY®.

The suspended back vented

façade of TONALITY® cladding tiles

proved to be a reliable system with

desirable building characteristics for

new building projects as well as for

renovations of existing buildings.

TONALITY® Classic Natural

TONALITY® Classic Finished Surface

TONALITY® Classic Special Series

TONALITY® Color

TONALITY® Color Natural Red FR3

TONALITY® Sun Protection

All notes and information, technical and graphic instructions, correspond to the current codes and standards of technology, as well as to our experiences based on this technology. The described applications represent examples and do not take into consideration custom designs and circumstances of individual cases. The information and the suitability of the material for the intended purposes must be examined with regard to the respective building project at any rate. Liability is excluded. This shall also apply to misprints and later changes of technical data.

Page 15: Tonality Ceramic Facade Brochure

15

Tonality® ADS Fixing SystemApplicationsThe Tonality Adaptive System (ADS) can be fastened on a horizontal or vertical primary substructure. This system is the preferred option for large surfaces and complex facades.

The primary substructure is subject to structural analysis suited to the respective building project and does not constitute a component of the Tonality® system range.

1 Tonality® Cladding tile

2 Tonality® Adaptive vertical profile aluminium

3 Tonality® Adaptive joint profile aluminium

4 Tonality® Protection against dismantling

5 Primary substructure aluminium L -profile

6 Primary substructure aluminium wall fastening

Open

joint profile

Closed

joint profile

Page 16: Tonality Ceramic Facade Brochure

16

Page 17: Tonality Ceramic Facade Brochure

17

Tonality® Sun ProtectionTonality sun protection systems are an enchanting accent to any building facade.Essentially, the addition of long linear elements to the building surface is a clever way to achieve artistic shading and to create depth.

More importantly, they also provide an effective means of protection from the intense ultraviolet rays of the sun. In summer months, heat gain through an unprotected glass can drive energy costs.Sunscreens can not only combat this phenomenon but, enhance the aesthetic appeal of the exterior elevation.

The Tonality sun protections are offered in three distinct shapes: lamella, baguette and squares.Each design creates a unique look and is offered in a variety of natural colours.

Lamella Tile

Tile height : 260 mm / 150 mm Tile

Baguette Tile

Tile height : 150 mm

Square-shaped Quadrat

Tile height : 40 mm / 50 mm / 70 mm

Page 18: Tonality Ceramic Facade Brochure

18

PRODUCT OVERVIEW

MaRS, Toronto ON – B+H Architects

Page 19: Tonality Ceramic Facade Brochure

19

ECONOMICAL ADVANTAGES • Shortconstructionperiodsasaresultofahighdegreeofprefabrication• Installationcarriedoutirrespectiveofweatherconditions• Scaffoldingrequiredtobeinplaceonlyforshortperiods• Simplecompensationofthebuildingtolerancespossible• Time-savinginstallationresultingfromstandardizedfasteningsystems• Simpleexchangeofindividualtiles• Durablematerial

POSSIBILITIES OF DESIGN• Individualplanningasaresultoftileformatsfrom150x300mmupto400x1,600mm• Individualplanningasaresultofcolorvarietyandwideproductrange• Colorandmaterialcombinationsarepossible• Coloredaccentuationofthejointispossible• Surfaces:smooth,grooved,pilasterstrip• Customtilesareavailable

ECOLOGICAL ADVANTAGES• High-qualityreuse• EnvironmentalManagingSystemDINENISO14000• Dismantlingwithsortedseparationofmaterialspossible• Materialrecyclinginthecourseoftheproductionprocess

ADAPTIVE SYSTEM (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum T-profile6 Primary sub-construction aluminum wall fastening

The primary sub-construction is subject tostructural analysis suited to the respectivebuilding project and does not constitute a componentof the TONALITY® system range.Details: page 25

Product Overview

Closed joint profile,

joint 8 mm

Open joint profile,

joint 8 mm

End profile for border,

no dismantling

protection

Closed, “not visible”

joint profile joint 2 mm

Page 20: Tonality Ceramic Facade Brochure

20

TONALITY® CLASSIC SERIES

The Data Centre, Toronto ON – WZMH & Urbacon

Page 21: Tonality Ceramic Facade Brochure

21

TONALITY® CLASSIC NATURAL AND CLASSIC FINISHED SURFACE WITH GRAFFITI PROTECTION*

Material: high-quality kinds of clay, burnt at over 1,200°C, Keralis procedure*Graffiti protection not available on all coloursColors: page 10 & 11Classification of fire resistance: A1 (DIN EN 13501-1)Application: Suspended back-vented façade for all kinds of buildings and building heights, as well as for interior design.Fastening: system-specific for the Adaptive System (ADS)

The TONALITY® Classic Finished Surface range includes a lasting graffiti protection. The protection is effective as of the

first day, i.e. already in the building phase. The freshening up or renewal of the protection required for conventional systems is not necessary here.

DELIVERY RANGETONALITY®

Max. module size (mm)

Module height(mm)

Tile height(mm)

Tolerance(mm)

Module width(mm)

Tile width(mm)

Tolerance(mm)

150 x 900 150 158 ± 2.0 900

Module width– joint width

± 1.0

175 x 900 175 183 ± 2.0 900 ± 1.0

200 x 1,600 200 208 ± 2.0 1,600 ± 1.0

225 x 1,600 225 233 ± 2.0 1,600 ± 1.0

250 x 1,600 250 258 ± 2.0 1,600 ± 1.0

300 x 1,600 300 308 ± 2.0 1,600 ± 1.0

400 x 1,600 400 408 ± 2.0 1,600 ± 1.0

SURFACEExecution smooth Execution grooved Execution pilaster strip

Product Overview

Page 22: Tonality Ceramic Facade Brochure

22

TONALITY® LAMELLE TILES

Kreiskrankenhaus in Buchen, Germany (foto Dietmar Strau SS, Besigheim )

Page 23: Tonality Ceramic Facade Brochure

23

TONALITY® BAGUETTE AND LAMELLE TILES, SQUARE-SHAPED QUADRAT

Material: high-quality kinds of clay, burnt at 1,200°C, Keralis procedureSurface: natural, without coatingColors: brick red (natural)Application: Privacy and sun protectionFastening: Due to the extremely different requirements, the fastening must be designed specifically

DELIVERY RANGE LAMELLELamelle

Trimmed size (mm) d x b Tile height (mm)

Lamelle 1: 60 x 450 260

Lamelle 2: 50 x 450 150

DELIVERY RANGE BAGUETTEBaguette

Trimmed size (mm) d x b Tile height (mm)

Baguette 65 x 450 150

DELIVERY RANGE SQUARE-SHAPED QUADRATQuadrat

Trimmed size (mm) d x b Tile height (mm)

Quadrat 1: 40 x 450 40

Quadrat 2: 50 x 450 50

Quadrat 3: 70 x 450 70

Product Overview

Lamelle 1 Lamelle 2 2 (special color)

Page 24: Tonality Ceramic Facade Brochure

24

TONALITY® CLASSIC SERIES

Fortinos, Stoney Creek ON – Turner Fleischer Architects

Page 25: Tonality Ceramic Facade Brochure

25

TONALITY® SYSTEM SUB-CONSTRUCTION ADAPTIVE SYSTEM ON METAL SUB-CONSTRUCTION

The TONALITY® Adaptive System (ADS) can be fastened on a horizontal or vertical pri-mary sub-construction. The vertical profiles of the TONALITY® Adaptive System can take joint profiles with closed, fine or open end profiles without joint. Miter cut corners require the use of the external corner profiles available for the left and right side, in the 3 system depths of 46, 56 and 66 mm. In the event of open corners with profiles and a system depth of 56 and 66 mm, the installation requires the use of the TONALITY® external corner profile of 30 x 30 mm. The TONALITY® supporting profile prevents the generation of noise in the agraffe retainers. Reveal/lintel profiles are available for the fastening in the area of windows and doors. Bias-cut tiles are fixed using TONALITY® gable clamps with special glue.

Choice of profile Tile height (mm) Profile length (mm)

The agraffe retainers producedifferent profiles and profilelengths of the sub-constructionas a result of the respectivetile height

150 2,694

175 2,794

200 2,794

225 2,694

250 2,744

300 2,694

400 2,794

DELIVERY RANGEIllustration Description Color / Material

TONALITY® Adaptive Vertical Profile 4635 x 60 x 35 mm forsystem depth 46 mm

SemimachinedAluminum

TONALITY® Adaptive Vertical Profile 5645 x 60 x 45 mm forsystem depth 56 mm

SemimachinedAluminum

TONALITY® Adaptive Vertical Profile 6655 x 60 x 55 mm forsystem depth 66 mm

SemimachinedAluminium

TONALITY® Joint profile closed(8 mm) 56 x 23 mmfor all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Joint profile closed(8 mm) 56 x 30 mm, flush

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Joint profile open56 x 31mm

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Joint profile “Fine Joint”(2 mm) 56 x 23 mmfor all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Joint profile “Fine Joint”(2 mm) 56 x 30 mm, flush

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Reveal/lintel profilenarrow, profile width 40 mm

for all system depths

SemimachinedAluminium

TONALITY® Reveal/lintel profilewide, profile width 100 mm

for all system depths

SemimachinedAluminium

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Illustration Description Color / Material

TONALITY® Vertical profile external corner46, 74 / 35 mm, usable on both sides

for system depth 46 mm

SemimachinedAluminum

TONALITY® Vertical profile external corner56, 74 / 35 mm, usable on both sides

for system depth 56 mm

SemimachinedAluminum

TONALITY® Vertical profile external corner66, 74 / 45 mm, usable on both sides

for system depth 66 mm

SemimachinedAluminium

TONALITY® End profile for border56 x 5 mm

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Supporting profile 60 mmFor all system depths and modules

RAL 7021(blackgray)Aluminium

TONALITY® External corner profile 30 x 30mm, For all modules with system depth

56 / 66 mm

RAL 7021(blackgray)Aluminium

TONALITY® Gable clampsFor all system depths and modules

RAL 7021(blackgray)Aluminium

Glue for gable clampsConsumption:

1 cartridge for 30 clamps

RAL 7021(blackgray)Aluminium

Sealing gasket profilefor wind barrier 27 x 64 mm

SemimachinedAluminium

Joint profile (wind barrier)8 / 17 mm

SemimachinedAluminium

Aluminium quality EN AW 5754 according to DIN EN 755-2

Page 26: Tonality Ceramic Facade Brochure

26

ADAPTIVE SYSTEM ON HORIZONTAL SUB-CONSTRUCTION

ADAPTIVE SYSTEM ON VERTICAL SUB-CONSTRUCTION

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Adaptive system (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile

aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum L-profile6 Primary sub-construction aluminum wall

fastening

The primary sub-construction is subject to structural analysis suited to the respective building project and does not constitute a component of the TONALITY® system range.

Adaptive system (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile

aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum T-profile6 Primary sub-construction aluminum wall

fastening

The primary sub-construction is subject to structural analysis suited to the respective building project and does not constitute a component of the TONALITY® system range.

Primary sub-constructionDistances, kinds of brackets and plugs, as well as rivets resp. drilling screws are subject to structural calculation for the respective building project!

TONALITY® Adaptive System

Page 27: Tonality Ceramic Facade Brochure

27

CALCULATION VALUES

Profile depth/system depth

17 mm / 46 mm 27 mm / 56 mm 37 mm / 66 mm

Cross-sectional area

1.72 cm2 2.12 cm2 2.52 cm2

Moment of inertia ly = 0.28 cm4lz = 7.97 cm4

ly = 1.22 cm4lz = 11.34 cm4

ly = 3.13 cm4lz = 14.71 cm4

Moment of resistance

Wyo = 0.24 cm3Wyu = 0.86 cm3Wyz = 2.66 cm3

Wyo = 0.66 cm3Wyu = 1.90 cm3Wyz = 3.78 cm3

Wyo = 1.26 cm3Wyu = 3.08 cm3Wyz = 4.90 cm3

DETAIL ROOF PARAPET EDGE, DETAIL BASE JOINT - ADAPTIVE SYSTEM

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations

The external vertical side of coverings or edge profiles should overlap the upper edge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm

The height of roof edge borders should be approx. 100 mm with roof pitches of up to 5° approx. 50 mm with roof pitches > 5° above the covering surface resp. gravel layer.Roof edge borders must have an inclination towards the roof side.

The projection of coverings or edge profiles must maintain a drip edge of at least 20 mm distance from the building components to be protected.

18 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations

The external vertical side of coverings oredge profiles should overlap the upperedge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm

The height of roof edge borders should beapprox. 100 mm with roof pitches of up to 5°approx. 50 mm with roof pitches > 5°above the covering surface resp. gravellayer.Roof edge borders must have an inclina-tion towards the roof side. The projection of coverings or edge pro-files must maintain a drip edge of at least20 mm distance from the building compo-nents to be protected.

Detail Roof Parapet Edge, Detail Base Joint - Adaptive System

SYSTEM CONSTRUCTION AND STANDARD DETAILS

H 1

H 1

H 2

H 2

T

T

Maßstab ca. 1:10

Calculation valuesProfile depth/system depth

Cross-sectional area

Moment of inertia

Moment of resistance

17 mm / 46 mm

1.72 cm2

ly = 0.28 cm4

lz = 7.97 cm4

Wyo = 0.24 cm3

Wyu = 0.86 cm3

Wyz = 2.66 cm3

27 mm / 56 mm

2.12 cm2

ly = 1.22 cm4

lz = 11.34 cm4

Wyo = 0.66 cm3

Wyu = 1.90 cm3

Wyz = 3.78 cm3

37 mm / 66 mm

2.52 cm2

ly = 3.13 cm4

lz = 14.71 cm4

Wyo = 1.26 cm3

Wyu = 3.08 cm3

Wyz = 4.90 cm3

E-module = 70,000 N/mm2, acc. to DIN 4113-1

Profile depth System depth

18Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 18

SYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

H1

H2

T

E-module = 70,000 N/mm2, acc. to DIN 4113-1

18 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations

The external vertical side of coverings oredge profiles should overlap the upperedge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm

The height of roof edge borders should beapprox. 100 mm with roof pitches of up to 5°approx. 50 mm with roof pitches > 5°above the covering surface resp. gravellayer.Roof edge borders must have an inclina-tion towards the roof side. The projection of coverings or edge pro-files must maintain a drip edge of at least20 mm distance from the building compo-nents to be protected.

Detail Roof Parapet Edge, Detail Base Joint - Adaptive System

SYSTEM CONSTRUCTION AND STANDARD DETAILS

H 1

H 1

H 2

H 2

T

T

Maßstab ca. 1:10

Calculation valuesProfile depth/system depth

Cross-sectional area

Moment of inertia

Moment of resistance

17 mm / 46 mm

1.72 cm2

ly = 0.28 cm4

lz = 7.97 cm4

Wyo = 0.24 cm3

Wyu = 0.86 cm3

Wyz = 2.66 cm3

27 mm / 56 mm

2.12 cm2

ly = 1.22 cm4

lz = 11.34 cm4

Wyo = 0.66 cm3

Wyu = 1.90 cm3

Wyz = 3.78 cm3

37 mm / 66 mm

2.52 cm2

ly = 3.13 cm4

lz = 14.71 cm4

Wyo = 1.26 cm3

Wyu = 3.08 cm3

Wyz = 4.90 cm3

E-module = 70,000 N/mm2, acc. to DIN 4113-1

Profile depth System depth

18Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 18

SYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

Page 28: Tonality Ceramic Facade Brochure

28

DETAIL ExTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM ON VERTICAL SUBCONSTRUCTION

Cladding tile tonality® 19

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

DETAIL ExTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM ON HORIZONTAL SUBCONSTRUCTION

Cladding tile tonality® 19

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

Cladding tile tonality® 19

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

Cladding tile tonality® 19

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

DETAIL INTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM

Cladding tile tonality® 19

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-

file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile

The fixation of the vertical profile is effected onan aluminum bracket.

Detail External Corner of Building – Adaptive System on Vertical Sub-Construction

Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction

A B

C D E

Detail Internal Corner of Building – Adaptive System

Internal corner 90° with adaptive system end profile

External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut

– Vertical profile external corner 45 x 74– Supporting profile

In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile

– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized

E6EV1 / semimachined)

E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03

19Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19

SYSTEM CONSTRUCTION AND STANDARD DETAILS

External corner 90° - TONALITY® on vertical primary sub-construction.A) External corner: TONALITY® with miter cut – Vertical profile external corner 45 x 74 – Supporting profileIn case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical profileis effected on an aluminum bracket.B) External corner: TONALITY® with corner profile – Vertical profile external corner 45 x 74 – Supporting profile – Visible external corner profileThe fixation of the vertical profile is effected onan aluminum bracket.

External corner 90° - TONALITY® on horizontal primary sub-construction.C) External corner: TONALITY® with miter

cut – Vertical profile external corner

45 x 74 – Supporting profile

In case of miter cut, the edges must have a bevel of 4 mm.D) External corner: TONALITY® with

corner profile – Vertical profile external corner

45 x 74 – Supporting profile – Visible external corner profile

(anodized E6EV1 / semimachined)

Internal corner 90° with adaptivesystem end profile

E) External corner: TONALITY® with vertical wind barrier for reduced wind pressure according to DIN 1055-4:2005-03

Page 29: Tonality Ceramic Facade Brochure

29

DETAIL WINDOW – ADAPTIVE SYSTEM

20 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Detail Window – Adaptive System

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Vertical sectionWindow, lintel and parapet

A) without sun protection

B) with integrated sun protection

C) parapet of cladding tiles

Maßstab ca. 1:5

Horizontal sectionWindow reveal with vertical primary sub-con-struction.

Horizontal sectionWindow reveal with horizontal primary sub-con-struction.

Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.

Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.

A

B C

20Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Vertical sectionWindow, lintel and parapet

A) without sun protection

B) with integrated sun protection

C) parapet of cladding tiles

Horizontal sectionWindow reveal with vertical primary sub-construction.

Horizontal sectionWindow reveal with horizontal primary sub-construction.

Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.

Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construction

Page 30: Tonality Ceramic Facade Brochure

30

ADAPTIVE PIECE ADDITIONAL SUPPORT

Cladding tile tonality® 21

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Detail Window – Adaptive System

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Vertical sectionWindow, lintel and parapet

A) without sun protection

B) with integrated sun protection

C) parapet of cladding tiles

Maßstab ca. 1:5

Horizontal sectionWindow reveal with vertical primary sub-con-struction.

Horizontal sectionWindow reveal with horizontal primary sub-con-struction.

Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.

Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.

A

B C

20Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20

Detail – Window Fitting Tile with Adapter Piece or Gable Clamp for Adaptive System

Adaptive Piece Additional Support

SYSTEM CONSTRUCTION AND STANDARD DETAILS

A B

C D

A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptivesystem. Fastening pinned from the back onto the profile of the adaptive system.

21Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 21

The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptive system. Fastening pinned from the back onto the profile of the adaptive system.

DETAIL – WINDOW FITTING TILE WITH ADAPTER PIECE OR GABLE CLAMP FOR ADAPTIVE SYSTEM

Cladding tile tonality® 21

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Detail Window – Adaptive System

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Vertical sectionWindow, lintel and parapet

A) without sun protection

B) with integrated sun protection

C) parapet of cladding tiles

Maßstab ca. 1:5

Horizontal sectionWindow reveal with vertical primary sub-con-struction.

Horizontal sectionWindow reveal with horizontal primary sub-con-struction.

Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.

Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.

A

B C

20Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20

Detail – Window Fitting Tile with Adapter Piece or Gable Clamp for Adaptive System

Adaptive Piece Additional Support

SYSTEM CONSTRUCTION AND STANDARD DETAILS

A B

C D

A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptivesystem. Fastening pinned from the back onto the profile of the adaptive system.

21Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 21SYSTEM CONSTRUCTION AND STANDARD DETAILS

A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes

D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes

Page 31: Tonality Ceramic Facade Brochure

31

TONALITY SYSTEM SUB-CONSTRUCTION OF ADAPTIVE SYSTEM ON WOODEN SUB-CONSTRUCTION

32 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

SYSTEM CONSTRUCTION AND STANDARD DETAILS

TONALITY® System Sub-Construction of Adaptive, Base Clinch Rail and Classic Profile Systemson Wooden Primary Sub-Construction

1

2

3

4

5

System structure of the Adaptive System

Adaptive System on horizontal wooden sub-construction

Base Clinch Rail Profile on vertical wooden sub-construction

1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive

System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile

1

2

3

4

1

2

3

5

4

System structure of the Base Clinch Rail System

System structure of the Classic Profile System

1 Wooden sub-construction2 Profile of the TONALITY® Base Clinch Rail

System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile

1 Wooden sub-construction2 Profile of the TONALITY® Classic Profile

System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile5 Joint profile of the Classic Profile System

32Planning & Application 2009 Cladding tiles TONALITY®

The installation of the Classic Profile System on a wooden sub-construction is possible as well.

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 32

32 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

SYSTEM CONSTRUCTION AND STANDARD DETAILS

TONALITY® System Sub-Construction of Adaptive, Base Clinch Rail and Classic Profile Systemson Wooden Primary Sub-Construction

1

2

3

4

5

System structure of the Adaptive System

Adaptive System on horizontal wooden sub-construction

Base Clinch Rail Profile on vertical wooden sub-construction

1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive

System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile

1

2

3

4

1

2

3

5

4

System structure of the Base Clinch Rail System

System structure of the Classic Profile System

1 Wooden sub-construction2 Profile of the TONALITY® Base Clinch Rail

System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile

1 Wooden sub-construction2 Profile of the TONALITY® Classic Profile

System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile5 Joint profile of the Classic Profile System

32Planning & Application 2009 Cladding tiles TONALITY®

The installation of the Classic Profile System on a wooden sub-construction is possible as well.

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 32

Adaptive System on horizontal wooden sub-construction

Detail Internal Corner of Building – Wooden Primary Sub-Construction

Cladding tile tonality® 33

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

Detail External Corner of Building – Wooden Primary Sub-Construction

Horizontal sectionExternal corner with external corner profile

Horizontal sectionExternal corner with miter cut

Detail Internal Corner of Building – Wooden Primary Sub-Construction

Horizontal sectionInternal corner

Detail Window – Wooden Primary Sub-Construction

Horizontal sectionWindow reveal with metal frame on wooden sub-construction

Vertical sectionWindow sill connection onwooden sub-construction

30

33Planning & Application 2009 Cladding tiles TONALITY®

wooden substructure 80x60insolation 60 mm

wooden substructure 80x60

TONALITY cladding element

vertical profil for external corner

done byinstaller

not restriced ventilation

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 33

Detail Window – Wooden Primary Sub-Construction

Cladding tile tonality® 33

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

Detail External Corner of Building – Wooden Primary Sub-Construction

Horizontal sectionExternal corner with external corner profile

Horizontal sectionExternal corner with miter cut

Detail Internal Corner of Building – Wooden Primary Sub-Construction

Horizontal sectionInternal corner

Detail Window – Wooden Primary Sub-Construction

Horizontal sectionWindow reveal with metal frame on wooden sub-construction

Vertical sectionWindow sill connection onwooden sub-construction

30

33Planning & Application 2009 Cladding tiles TONALITY®

wooden substructure 80x60insolation 60 mm

wooden substructure 80x60

TONALITY cladding element

vertical profil for external corner

done byinstaller

not restriced ventilation

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 33

SYSTEM CONSTRUCTION AND STANDARD DETAILS

System structure of the Adaptive System1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile

Horizontal sectionInternal corner

Horizontal sectionWindow reveal with metal frame onwooden sub-construction

Vertical sectionWindow sill connection onwooden sub-construction

Page 32: Tonality Ceramic Facade Brochure

32

TONALITY® ADAPTIVE SYSTEM T-LINE®

SYSTEM CONSTRUCTION AND STANDARD DETAILS

The TONALITY® System sub-construction T-Lineallows to create the classic appearance ofbrickwork. It is suitable for all kinds of tiles andtile sizes. As an adaptive system, T-Line can berealized on vertical as well as on horizontalsub-constructions.

The TONALITY® Adaptive System T-Line consistsof type A and type B profiles that are fastenedalternately on the primary sub-construction.Type A and type B joint profiles are available asjoint profile with a closed joint of 8 mm.

34 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

TONALITY® Adaptive System T-Line®

The TONALITY® System sub-construction T-Lineallows to create the classic appearance ofbrickwork. It is suitable for all kinds of tiles andtile sizes. As an adaptive system, T-Line can berealized on vertical as well as on horizontalsub-constructions.

The TONALITY® Adaptive System T-Line consistsof type A and type B profiles that are fastenedalternately on the primary sub-construction.Type A and type B joint profiles are available asjoint profile with a closed joint of 8 mm.

34Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 34

Page 33: Tonality Ceramic Facade Brochure

33

TONALITY® ADAPTIVE SYSTEM T-LINE®

Cladding tile tonality® 35

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

TONALITY® Adaptive System T-Line

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Delivery range: Illustration Description

TONALITY® T-Line vertical profile type A35 x 60 x 35 mm

system depth 46 mm

TONALITY® T-Line vertical profile type A45 x 60 x 45 mm

system depth 56 mm

TONALITY® T-Line vertical profile type A55 x 60 x 55 mm

system depth 66 mm

TONALITY® T-Line joint profile type Aclosed 8 mm56 x 23 mm

Color / Material

SemimachinedAluminium

SemimachinedAluminium

SemimachinedAluminium

RAL 7021(blackgray)Aluminium

Illustration Description

TONALITY® T-Line vertical profile type B35 x 60 x 35 mm

system depth 46 mm

TONALITY® T-Line vertical profile type B45 x 60 x 45 mm

system depth 56 mm

TONALITY® T-Line vertical profile type B55 x 60 x 55 mm

system depth 66 mm

TONALITY® T-Line joint profile type Bclosed 8 mm56 x 23 mm

Color / Material

SemimachinedAluminium

SemimachinedAluminium

SemimachinedAluminium

RAL 7021(blackgray)Aluminium

Aluminium quality = EN AW 5754 according to DIN EN 755-2

35Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 35

DELIVERY RANGE:

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Illustration Description Color / Material

TONALITY® T-Line vertical profile type A35 x 60 x 35 mm

system depth 46 mm

SemimachinedAluminum

TONALITY® T-Line vertical profile type A45 x 60 x 45 mm

system depth 56 mm

SemimachinedAluminum

TONALITY® T-Line vertical profile type A55 x 60 x 55 mm

system depth 66 mm

SemimachinedAluminium

TONALITY® T-Line joint profile type Aclosed 8 mm56 x 23 mm

RAL 7021(blackgray)Aluminium

Illustration Description Color / Material

TONALITY® T-Line vertical profile type B35 x 60 x 35 mm

system depth 46 mm

SemimachinedAluminum

TONALITY® T-Line vertical profile type B45 x 60 x 45 mm

system depth 56 mm

SemimachinedAluminum

TONALITY® T-Line vertical profile type B55 x 60 x 55 mm

system depth 66 mm

SemimachinedAluminium

TONALITY® T-Line joint profile type Bclosed 8 mm56 x 23 mm

RAL 7021(blackgray)Aluminium

Page 34: Tonality Ceramic Facade Brochure

34

TONALITY® ADAPTIVE SYSTEM SIDING®

SYSTEM CONSTRUCTION AND STANDARD DETAILS

The TONALITY® Siding sub-construction is perfectly suitable for the design of a TONALITY® cladding tile façade with the appearance of weatherboarding.

The realization of this TONALITY® system subconstruction allows for the use of all kinds of tiles and tile sizes.

The inclined position and the overlapping of the TONALITY® tiles result from the shape of the profiles of the TONALITY® system sub-construction. The continuous vertical joints can be designed as a closed joint of 8 mm or as a fine joint of 2 mm, as well as flush or set back with regard to the front edge of the tile.

36 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

Adaptive System TONALITY® SIDING®

The TONALITY® Siding sub-construction is per-fectly suitable for the design of a TONALITY®

cladding tile façade with the appearance ofweatherboarding.The realization of this TONALITY® system sub-construction allows for the use of all kinds oftiles and tile sizes.The inclined position and the overlapping of theTONALITY® tiles result from the shape of theprofiles of the TONALITY® system sub-construc-tion.The continuous vertical joints can be designedas a closed joint of 8 mm or as a fine joint of 2mm, as well as flush or set back with regard tothe front edge of the tile.

36Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 36

36 Cladding tile tonality®

SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS

Adaptive System TONALITY® SIDING®

The TONALITY® Siding sub-construction is per-fectly suitable for the design of a TONALITY®

cladding tile façade with the appearance ofweatherboarding.The realization of this TONALITY® system sub-construction allows for the use of all kinds oftiles and tile sizes.The inclined position and the overlapping of theTONALITY® tiles result from the shape of theprofiles of the TONALITY® system sub-construc-tion.The continuous vertical joints can be designedas a closed joint of 8 mm or as a fine joint of 2mm, as well as flush or set back with regard tothe front edge of the tile.

36Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 36

Page 35: Tonality Ceramic Facade Brochure

35

TONALITY® ADAPTIVE SYSTEM SIDING®

DELIVERY RANGE:

Aluminium quality = EN AW 5754 according to DIN EN 755-2

Cladding tile tonality® 37

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Adaptive System TONALITY® SIDING®

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Horizontal section external corner of building - Siding

tile length

axis

"TONALITY® "-adaptive end lug 56x5

"TONALITY® "-SIDING vertical profile

8

vertical supportalu metal sheet,by contractor

4 4

"TONALITY® "cladding tile

219

60

"TON

ALITY®

"cl

addi

ng ti

le

2 19

unre

stric

ted

vent

ilatio

n

varia

bel

syst

em d

epth

66

44intermediate inset

fitting piecefor tile sections

with at least tworestoring pins

see ANo. dwg 746

19 46

e.g. system depth 66

unre

strict

edve

ntila

tion

12

12

journal as partof the standardcarrier systemSID

lower hookmay beturned aroundor cut off forconvencience

36

Horizontal section internal corner of building - Siding Vertical section window, lintel and parapet - Siding

fitted tile

journal as partof the standardcarrier systemSID

intermediate insetfitting piece

for tile sectionswith at least two

restoring pinssee ANo. dwg 746

lower hookmay beturned aroundor cut off forconvencience

Delivery range: Illustration Description

TONALITY® Siding vertical profile50 x 60 x 50 mm

for system depth 66 mm

TONALITY® Siding vertical profile60 x 60 x 60 mm

for system depth 76 mm

TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm

for all system depths

TONALITY® Siding joint profileClosed, flush, 8 mm

56 x 48 mm, for all system depths

Color / Material

MachinedAluminium

MachinedAluminium

RAL 7021(blackgray)Aluminium

RAL 7021(blackgray)Aluminium

Illustration Description

TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm

for all system depths

TONALITY® Siding joint profile“Fine joint”, 2 mm, flush

56 x 48 mm for all profile depths

TONALITY® Siding external corner profile57 x 57 mm for system depths

66 mm and 76 mm

TONALITY® Siding adapter piece50 x 45 mm

for all system depths

Color / Material

RAL 7021(blackgray)Aluminium

RAL 7021(blackgray)Aluminium

Aluminium

SemimachinedAluminium

Aluminium quality = EN AW 5754 according to DIN EN 755-2

37Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 37

Horizontal section external corner of building - Siding

Cladding tile tonality® 37

SYSTEMCONSTRUCTIONANDSTANDARDDETAILS

Adaptive System TONALITY® SIDING®

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Horizontal section external corner of building - Siding

tile length

axis

"TONALITY® "-adaptive end lug 56x5

"TONALITY® "-SIDING vertical profile

8

vertical supportalu metal sheet,by contractor

4 4

"TONALITY® "cladding tile

219

60

"TON

ALITY®

"cl

addi

ng ti

le

2 19

unre

stric

ted

vent

ilatio

n

varia

bel

syst

em d

epth

66

44

intermediate insetfitting piece

for tile sectionswith at least two

restoring pinssee ANo. dwg 746

19 46

e.g. system depth 66

unre

strict

edve

ntila

tion

12

12

journal as partof the standardcarrier systemSID

lower hookmay beturned aroundor cut off forconvencience

36

Horizontal section internal corner of building - Siding Vertical section window, lintel and parapet - Siding

fitted tile

journal as partof the standardcarrier systemSID

intermediate insetfitting piece

for tile sectionswith at least two

restoring pinssee ANo. dwg 746

lower hookmay beturned aroundor cut off forconvencience

Delivery range: Illustration Description

TONALITY® Siding vertical profile50 x 60 x 50 mm

for system depth 66 mm

TONALITY® Siding vertical profile60 x 60 x 60 mm

for system depth 76 mm

TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm

for all system depths

TONALITY® Siding joint profileClosed, flush, 8 mm

56 x 48 mm, for all system depths

Color / Material

MachinedAluminium

MachinedAluminium

RAL 7021(blackgray)Aluminium

RAL 7021(blackgray)Aluminium

Illustration Description

TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm

for all system depths

TONALITY® Siding joint profile“Fine joint”, 2 mm, flush

56 x 48 mm for all profile depths

TONALITY® Siding external corner profile57 x 57 mm for system depths

66 mm and 76 mm

TONALITY® Siding adapter piece50 x 45 mm

for all system depths

Color / Material

RAL 7021(blackgray)Aluminium

RAL 7021(blackgray)Aluminium

Aluminium

SemimachinedAluminium

Aluminium quality = EN AW 5754 according to DIN EN 755-2

37Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 37

Horizontal section external corner of building - Siding Vertical section window, lintel and parapet - Siding

SYSTEM CONSTRUCTION AND STANDARD DETAILS

Illustration Description Color / Material

TONALITY® Siding vertical profile50 x 60 x 50 mm

for system depth 66 mm

MachinedAluminum

TONALITY® Siding vertical profile60 x 60 x 60 mm

for system depth 76 mm

MachinedAluminum

TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Siding joint profileClosed, flush, 8 mm

56 x 48 mm, for all system depths

RAL 7021(blackgray)Aluminium

Illustration Description Color / Material

TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm

for all system depths

RAL 7021(blackgray)Aluminium

TONALITY® Siding joint profile“Fine joint”, 2 mm, flush

56 x 48 mm for all profile depths

RAL 7021(blackgray)Aluminium

TONALITY® Siding external corner profile57 x 57 mm for system depths

66 mm and 76 mmAluminium

TONALITY® Siding adapter piece50 x 45 mm

for all system depths

SemimachinedAluminium

Page 36: Tonality Ceramic Facade Brochure

36

CLAY AS A RAW MATERIALAs a raw material, clay has been well known since Antiquity. And ever since the discovery of clay ceramics about 10,000 - 8,000 BC, the popularity of clay is based on the exceptional plasticity of wet clays. Thus, clay represents one of the oldest natural raw materials of our days. Clays are weathering and erosion products of the Earth’s crust. They occur

in the continental and maritime area. Their variety depends on the physical and chemical conditions prevailing at the time of their formation. These conditions allow for a broad spectrum of characteristics and thus for the broad possibilities of application of clays. The quality clays used to manufacture the TONALITY® productsquarried in the Westerwald area of

Germany. These clays are considered to be among the best kinds of clay worldwide and are known for their particular purity.TONALITY® cladding tiles show a profile on the reverse and are attached onto vertical support frames made of aluminum by means of positive locking.

MANUFACTURING PROCEDURETONALITY® cladding tiles are manufactured in ultra-modern production plants using a vacuum extrusion method, dried and burnt. In the course of the patented Keralis procedure, the raw material clay is dried, processed into finest powdered clay and completely dyed in finely graduated ratios of color mixtures.

The products are subsequently burnt at temperatures of approx. 1,200°C.A sintering process will take place in the course of the baking as a result of the processing of highquality raw materials and the high baking temperature. This sintering allows for the impermeabilityand the smooth surface. The production

of the TONALITY® cladding tiles is taking place in the production plants of the manufacturer CREATON in accordance with DIN EN ISO 9001 Quality Management System and DIN EN ISO 14000 Environmental Management System.

CHARACTERISTICS Non-combustible

(Building Material Class A1) Weather and frost-resistant Waterproof Rot-resistant

Resistant to UV-light Shockproof Classic Finished Surface and optionally Color with permanent graffiti protection

Low weight of the system of less than 35 kg/m2

Tight-fitting installation between tile andsystem sub-construction

Installation can be carried out irrespective of weather conditions

AREAS OF APPLICATIONSuspended back-vented cladding. Applicable for external as well as internal walls of any kind of building or building height. A National Technical Approval recorded under No. Z-32.1-

567 in accordance with DIN 18516 of the Deutsches Institut für Bautechnik, a German institute of the Federal and Laender Govern-ments for a uniform fulfillment of technical tasks in the field

of public law, can be presented for the TONALITY® cladding system. In addition, TONALITY® products allow for the design of sun and privacy protections.

SYSTEM ADVANTAGES OF THE SUSPENDED, BACKVENTED FAçADE

38 Cladding tile tonality®

PLANNINGBASESANDPROCESSING

Clay as a raw material

Manufacturing procedure

PLANNING BASES AND PROCESSING

As a raw material, clay has been well knownsince Antiquity. And ever since the discovery ofclay ceramics about 10,000 - 8,000 BC, the popu-larity of clay is based on the exceptional plasticityof wet clays. Thus, clay represents one of the old-est natural raw materials of our days. Clays areweathering and erosion products of the Earth’s

crust. They occur in the continental and maritimearea. Their variety depends on the physical andchemical conditions prevailing at the time of theirformation. These conditions allow for a broadspectrum of characteristics and thus for the broadpossibilities of application of clays. The qualityclays used to manufacture the TONALITY® products

quarried in the Westerwald area of Germany. Theseclays are considered to be among the best kinds ofclay worldwide and are known for their particularpurity.TONALITY® cladding tiles show a profile on thereverse and are attached onto vertical support framesmade of aluminum by means of positive locking.

TONALITY® cladding tiles are manufactured inultra-modern production plants using a vacuumextrusion method, dried and burnt. In the course ofthe patented Keralis procedure, the raw materialclay is dried, processed into finest powdered clayand completely dyed in finely graduated ratios of

color mixtures. The products are subsequentlyburnt at temperatures of approx. 1,200°C.A sintering process will take place in the course ofthe baking as a result of the processing of high-quality raw materials and the high baking temper-ature. This sintering allows for the impermeability

and the smooth surface. The production of theTONALITY® cladding tiles is taking place in the pro-duction plants of the manufacturer CREATON inaccordance with DIN EN ISO 9001 QualityManagement System and DIN EN ISO 14000Environmental Management System.

Characteristics■ Non-combustible

(Building Material Class A1)■ Weather and frost-resistant■ Waterproof■ Rot-resistant

■ Resistant to UV-light■ Shockproof■ Classic Finished Surface and optionally Color

with permanent graffiti protection

■ Low weight of the system of less than 35 kg/m2

■ Tight-fitting installation between tile andsystem sub-construction

■ Installation can be carried out irrespective ofweather conditions

Areas of applicationSuspended back-vented cladding. Applicablefor external as well as internal walls of any kindof building or building height. A National TechnicalApproval recorded under No. Z-32.1-567 in

accordance with DIN 18516 of the DeutschesInstitut für Bautechnik, a German institute ofthe Federal and Laender Govern-ments for auniform fulfillment of technical tasks in the field

of public law, can be presented for the TONALITY®

cladding system. In addition, TONALITY® prod-ucts allow for the design of sun and privacyprotections.

System advantages of the suspended, back-vented façade1 Insulating material2 Ventilation3 Adjustable wall

fastening withthermal separator

4 Supporting profile5 System-specific

sub-construction6 Cladding tile

Diffusion-open construc-tion, prevented moisturepenetration to the wallsand insulation

Each insulation thicknesscan be realized

Protection of buildingcomponents againstweather effects

Building periods can beestimate as installationis carried out irrespec-tive of weather

DisposalCladding tiles can be disposed of as construc-tion and demolition waste under the waste keynumber 17.01.03 (tiles, bricks and ceramicsaccording to the European Waste Catalogue).

The separation of materials allows for theirsupply for high-quality recycling. The aluminumprofiles can be disposed of as reusable materi-al or as construction and demolition waste

under the waste key number 17.04.02(Aluminum according to the European WasteCatalogue).

Storage and transportCladding tiles and sub-construction arepacked on pallets and wrapped with edge pro-

tection in shrink foil in order to prevent dam-age and soiling.

Wall structure with TONALITY® cladding tiles Cladding system with the lowest susceptibility to damage (Rainer Oswald among others: Third Report on Damages to Buildings, Bonn 1998)

38Planning & Application 2009 Cladding tiles TONALITY®

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 38

STORAGE AND TRANSPORTCladding tiles and sub-construction are packed on pallets and wrapped with edge protection in shrink foil in order to prevent damageand soiling.

PLANNING BASICS & INSTALLATION

Page 37: Tonality Ceramic Facade Brochure

37

DIN 18516DIN EN 1304

DIN EN 539-2

Action on structuresDIN 1055, Part 1, 4 and 5

Metal worksDIN 18800

DIN 4113, Part 1

Timber structuresDIN 1052, Part 1 to 4

MasonryDIN 1053, Part1

DIN 1045

Thermal insulationDIN 4108, Part 1 to 4

Moisture protection subject to climateconditions DIN EN 13162

Fire protectionDIN EN 13501

Sound insulationDIN 4109

DIN 18005

TolerancesDIN 18202DIN 1960DIN 1961

DIN 4420, Part 1, 2 und 4DIN 18335DIN 18360DIN 18339DIN 18338DIN 18364DIN 18384DIN 18451DIN 18800DIN 18200DIN 52253

Special Regulations of the Roofing TradeCladding for external walls, back-ventedRoofing tiles and fittings, product definitions and specificationsBurnt-clay roofing tiles

Self-weight, wind loads, design loads

Steel structures, design and constructionAluminum construction under predominantly static loading

Timber structures

MasonryConcrete and reinforced and prestressed concrete structures

Thermal insulation in buildings, thermal protection energy economy

Thermal insulation products for buildings

Fire classification of building materials and building components, Fire protection Regulations (BTR)

Sound insulation in buildingNoise abatement in town planning

Dimensional tolerances in building constructionContract procedures for building works, Part AContract procedures for building works, Part BService and working scaffoldsContract procedures for building works, steel construction worksContract procedures for building works, metal construction worksContract procedures for building works, sheet metal worksContract procedures for building works, roof covering and roof sealing worksContract procedures for building works, works for protection of steel structuresLightning protection systemsScaffolding worksSteel structuresAssessment of conformity, building materials, building components, designFrost resistance, Part 1

Fire classification:Bulk density:

Water absorption capacity:Frost resistance:

combustible, A1 (DIN EN 13501-1)2.25 g/cm3< 6%given according to DIN EN 539-2 DIN

STANDARDS, REGULATIONS, APPROVALS

The above listing shows only an excerpt of the regulations and standards to be observed. It does not claim completeness.

TECHNICAL DATA TONALITY®

PLANNING BASICS & INSTALLATION

Page 38: Tonality Ceramic Facade Brochure

38

ADAPTIVE SYSTEM (ADS)

Installation of vertical profiles:

The TONALITY® vertical profiles must be screwed resp. riveted to the height and the façade grid of the

already installed sub- construction. The distance between brackets and the kind of fastening must be

effected according to the static requirements of the building. Fixing material admitted for use by the

construction supervising authority must be used at any rate. As already described for the primary sub-

construction, gaps for the linear expansion of profiles must be allowed for at the joints in the course of the

profile installation. It must be paid attention to the fact that the required gap at the joint is executed observing

the same height grid of the primary sub-construction (Tprofile) and of the agraffe profile. In case of formation

of several bearing profiles one above the other, the lengths of the bearing profiles as well as the distance

between the fixed points of two bearing profiles following each other must not exceed 2.80 m. The gap at

the joint of the cladding tiles and bearing profiles must be at least 6 mm. Corresponding gaps at the joints

must be allowed for in the event of site trimming. Joints of the bearing profiles may not be overlapped by

cladding tiles.

Installation of joint profile:

In order to fasten the joint profile, it is clamped into the vertical profile. At the same time, it rests on the

beads executed in the webs of the joint profile on the reverse side. As a rule, it is secured against falling off

through insertion of the tiles. At the same time, the tiles are pushed to the vertical profile by the joint profile

in order to avoid the generation of noise of the tiles in case of load from wind pressure. Attention must be

paid to the height locks of the system profiles when inserting the joint profile and to the fact that the joint

profile is inserted in such way that the required clamping effect of the tiles is achieved. In case of soffits,

we recommend to screw the joint profile onto the vertical profile in order to completely rule out a possible

horizontal shifting of the joint profile and of the inserted tiles.

PLANNING BASICS & INSTALLATION

Page 39: Tonality Ceramic Facade Brochure

39

EFFECTIVE SPANSMaximum effective spans of the TONALITY® cladding tiles as single-span girders under positive wind load for

the ADS System

Positive wind load [kN/m2] +0.50 +0.80 +1.00 +1.50 +2.00 +2.50 +3.00

Maximum effective span [m]

Tile 150* 1.20 1.20 1.20 1.20 1.10 0.98 0.89

Tile 175 1.17 0.96 0.83 0.68 0.59 0.52 0.48

Tile 200 1.20 1.15 1.00 0.82 0.71 0.63 0.58

Tile 225 1.20 1.02 0.88 0.72 0.63 0.56 0.51

Tile 250* 1.20 1.20 1.20 1.04 0.90 0.81 0.74

Tile 300* 1.20 1.20 1.20 0.99 0.88 0.77 0.70

* The tiles 150, 250 and 300 may only be used with the systems ADS and BAS

Maximum effective spans of the TONALITY® cladding tiles as single-span girders under negative wind load

(wind suction) for the ADS System

Negative wind load [kN/m2] –0.50 -0.80 -1.00 -1.50 -2.00 -2.50 -3.00

Maximum effective span [m]

Tile 150* 1.20 1.20 1.20 1.20 1.20 1.20 1.07

Tile 175 1.20 1.20 0.97 0.65 0.49 0.39 0.32

Tile 200 1.20 1.13 0.85 0.57 0.43 0.34 0.28

Tile 225 1.20 1.20 0.98 0.65 0.49 0.39 0.33

Tile 250* 1.20 1.20 1.20 1.20 1.20 0.96 0.80

Tile 300* 1.20 1.20 1.20 1.11 0.83 0.67 0.56

* The tiles 150, 250 and 300 may only be used with the system ADS

PLANNING BASICS & INSTALLATION

Ordering and planning instructions Determine the distance of the façade to the carcass of the building taking into account the thickness of the insulation and the unrestricted ventilation (see DIN 18516). The established distance is important for your order of the primary sub-construction.

Plan the module sectioning (tile lengths) in agreement with the architect/building owner methodically. In this context, it will be necessary to verify details, connections, etc., by presentation of drawings.

Perform the site measuring and determine the quantities of tiles, profiles, wall brackets, joining plates, etc.

Determine the profiles, wall brackets, connection components and the plugs admitted for this use by the construction supervising authority. Perform static calculations for loadbearing profiles and anchorings and if necessary, have these calculations reviewed.

Perform the sectioning of profiles according to length

Profile Tile height with max.length tile length of2.694 mm = 18 x 150 mm x 900 mm2.794 mm = 16 x 175 mm x 900 mm2.794 mm = 14 x 200 mm x 1.600 mm2.694 mm = 12 x 225 mm x 1.600 mm2.744 mm = 11 x 250 mm x 1.600 mm2.894 mm = 9 x 300 mm x 1.600 mm2.794 mm = 7 x 400 mm x 1.600 mm■

As a rule, the length of the T-profile must correspond to the length of the „TONALITY“- vertical profile in case of vertical sub-construction. The façade must be installed free of constraint forces through fixed and floating point connections.

Order the tiles indicating their dimensions for trimming to size. In case of special lengths of the profiles (only after consultation), the installer must draw up production plans.

In order to avoid interruptions of the installation due to breakage or clippings, it is recommended to add on approx. 5 % to the required amount (depending on the building project 5 –15%).

The clear and biding order is placed electronically using the respective order form, which will be submitted by our Sales Service.

Page 40: Tonality Ceramic Facade Brochure

40

ADAPTIVE SYSTEM (ADS)

Cladding tile tonality® 45

PLANNINGBASESANDPROCESSING

Adaptive System (ADS) Base Clinch Rail System (BAS)

PLANNING BASES AND PROCESSING

Base Clinch Rail System (BAS)

Zu

Zo

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

*

joint profile

L

6.

E

Baseclinch rail

profile

grid

hei

ght

grid

hei

ght

dim

ensi

on L

A

4

6.*

* Thermal linear expansion requir 6 mm between both 2 adjacent (see NTA National Technical Ap

26

Zu

Zo

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

Zo

Zu

* Thermal linear expansion least 6 mm between both (see NTA National Technic

L

Prgr

ZoZu

grid h

eig

ht

Classicverticalprofile

*

joint profile

grid h

eig

ht

dim

en

sion

L

A

6.

E

Zo

Zu

M

26

42

,5

Neoprene

Module

150

175

200

225

250

300

400

No. ofmodules

18

16

14

12

11

9

7

Size L

2694

2794

2794

2694

2744

2694

2794

Size A

45

45

52

45

52

102

102

Size B

75

100

100

150

150

150

200

Size C

75

75

100

75

100

150

200

Size E

24

24

42

24

42

42

92

Size M

12

12

30

12

30

30

80

Adaptive System (ADS)

Module

150

175

200

225

250

300

400

No. ofmodules

18

16

14

12

11

9

7

Size L

2694

2794

2794

2694

2744

2694

2794

Size A

56.5

56.5

63.5

56.5

63.5

113.5

113.5

Size B

75

100

100

150

150

150

200

Size C

75

75

100

75

100

150

200

Size E

12.5

12.5

30.5

12.5

30.5

30.5

80.5

Size M

12

12

30

12

30

30

80

Classic Profile System (CLS)

Module

150

175

200

225

250

300

400

No. ofmodules

18

16

14

12

11

9

7

Size L

2694

2794

2794

2694

2744

2694

2794

Size A

57

57

64

57

64

114

114

Size B

75

100

100

150

150

150

200

Size C

75

75

100

75

100

150

200

Size E

75

100

100

150

150

150

80

45Planning & Application 2009 Cladding tiles TONALITY®

Zo: Tile fastening at the topZu: Tile fastening at the bottom

Profile length = number of modules less 6 mm * For thermal expansion reasons, the joint dis-tance of the tiles and profiles must be at least 6mm (see Technical Approval).

TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 45

Zo: Tile fastening at the topZu: Tile fastening at the bottom

Profile length = number of modules less 6 mm

ADAPTIVE SYSTEM (ADS)Module +0.50 Size L Size A Size B Size C Size E Size M

150 18 2694 45 75 75 24 12

175 16 2794 45 100 75 24 12

200 14 2794 52 100 100 42 30

225 12 2694 45 150 75 24 12

250 11 2744 52 150 100 42 30

300 9 2694 102 150 150 42 30

400 7 2794 102 200 200 92 80

PLANNING BASICS & INSTALLATION

Page 41: Tonality Ceramic Facade Brochure

43

REFERENCES

The Data Centre, Toronto ON – WZMH & Urbacon

Fortinos, Vaughan ON – Turner Fleischer Architects

MaRS, Toronto ON – B+H Architects

Page 42: Tonality Ceramic Facade Brochure

44

Engineered Assemblies Inc.

1.866.591.7021info@engineeredassemblies.comEngineeredAssemblies.com

brilliant buildings