claddingclay tilesTonality®
The Wave, D
enmark, H
enning Larsen Architects
2
Natural clay sets the toneTonality tilesNatural fired clay tiles, made from the finest Westerwald clay will give your commercial, public and even residential building a natural terracotta cladding look!With an easy and user friendly installation, different joint options and a wide variety of surfaces and colours, Tonality clay tiles will be an inspiration for everybody!
Easy installation, lift and lock solutionWe offer a comprehensive terracotta rainscreen system featuring lift and lock technology with aluminum vertical profiles, horizontal sub-grits, wall brackets and trim pieces.It is a genius single-skin cladding solution, proven to be stronger than the most traditional systems.
Maggie’s Cancer Caring Centers, United Kingdom – Architect Piers Gough Barham Park, United Kingdom – PRP Architects
3
Fine surface
Solid
Longlasting
4
ContentsProduct Overview Preface 5 Ventilated Façade 6 Advantages 10 Colour Chart 12 TONALITY® Adaptive Fixing System 15 Sun Protection 17 Product Overview 19 TONLAITY® Classic 21 TONALITY® Baguettes, Lamelle Tiles & Square-shaped Quadrats 23
System Construction TONALITY® System Sub-Construction Adaptive & Standard Details System on Metal Sub-Construction 25 TONALITY® System Sub-Construction Adaptive System on Wooden Sub-Construction 31 TONALITY® Adaptive System T-Line® 32 TONALITY® Adaptive System Siding® 34
Planning Basics General & Technical Information on & Installation TONALITY® Cladding Tiles 36 Round Walls with Standard Cladding Tiles 41 Special Designs 42
References Engineered Assemblies brilliant buildings 43
Technical status 02/2014All notes, technical and graphic information correspond to the current state of the art and to our experience based on this. The installers described are examples and do not take into consideration the conditions specific to individual cases. The information given and the suitability of the materials for their proposed use must be checked by the purchaser in all cases. We (companies of Etex group) accept no liability. This also applies in respect to misprints and subsequent change of a technical nature.
5
PrefaceCLAY TILE FAçADE TONALITY®
The clay tile façade TONALITY® extends the product range for suspended back vented facades with an appealing natural material. TONALITY® cladding tiles have represented highest quality, frost resistance and durability for decades now. The range comprises through colored burnt-clay tiles with natural surface texture, cladding tiles with matt and glossy surface finish and durable graffiti protection, as well as color-glazed tiles in a large variety of colors. The sun and privacy protection elements “Lamelle” and “Baguette” are completed by the new square-shaped tile “Quadrat”. Components of the Classic range are also available with smooth, pilaster strip and grooved surfaces. The compatibility of the system consisting of the TONALITY® cladding tile and of the system sub construction allows for fast, time-saving installation.
All cladding tiles of the TONALITY® range are non-combustible (Fire resistance acc. to Building Material Class A1). With formats from 150 x 300 mm up to 400 x 1,600 mm, the range opens up broad possibilities of design and material combinations with fiber cement panels of large format.
The following pages are intended to evoke design ideas, and as a practical guide to construction and realization. Whether it is an office complex, a commercial building or school – the illustrated buildings will convince you with regard to their aesthetic appeal and their economic efficiency. And even in building renovations, the suspended back-vented façade of TONALITY® cladding tiles proves to be a reliable system with favorable building characteristics.
Our qualified façade experts stand ready to give you custom and project-related advice either by phone or on location. We are pleased to assure you of our strong support during the course of all building stages, particularly pertaining to detail planning, invitations of tenders or economical optimization. Take advantage of our knowledge and expertise of future-oriented façade systems. We are open to your ideas.
6
Ventilated facadeOriginated in Scandinavia centuries ago, the ventilated facade (rainscreen) technique is now very prominent in areas with demanding climatic conditions.In the terracotta rainscreen system, the outer tile deflects rain and sun heat away from the building. The ventilation space allows air to freely circulate behind the tile, creating a well ventilated and comfortable inner building.
VersatilityThe ventilated facade construction principle combines the scalability of curtain wallconstruction with the creative versatility and adaptability offered by traditional buildingtechniques.
Less is moreA ventilated facade system has minimal thickness and weight, yet it offers maximum performance.
HealthyThe ventilated facade construction principle avoids cold bridges, eliminating condensation and mould growth.
7
Terracotta rainscreen
Ventilation spaceOuter layer
Fixing system
8
Tonality®
9
10
AdvantagesCreativeAvailable in an endless range of colours and sizesPossibility to play with tile formats from 150x300mm up to 600x2000mmProduced in different surfaces: smooth, grooved, pilaster strip & waved version
EconomicalOne layer means less weight & less use of substructureHigh wind pressure resistance due to rear strengthening hanging systemThe time saving “lift & lock” system ensures a fast and precise installation
Maintenance freeFine & smooth surface which ensures no contaminationPermanent “Graffiti Protection” is included in all finishes except for natural Brick Red finish
EcologicalEnvironmental Product DeclarationEnvironmental Managing System DIN EN ISO 14000
Fortinos, Stoney Creek ON – Turner Fleischer Architects
11
St. George Island, United Kingdom
Design possibilities
Kinderhaus Pertinsel, Austria – Architect Lothar Huber
12
Colour Chart Tonality®
Available surface options | smooth
Tonality® Siena
70100 Anthracite 70102 Red 70103 Beige 70101 White
Tonality® Travertin
69900 Yellow 69901 Red 69902 Beige 69903 Grey
Available surface options | smooth
grooved one pilaster stripe
Tonality® Natur
70017 Toscana 70002 Beige 70024 Cream light 70015 Pearl grey
70010 Flint grey 70021 Umbra grey *70019 Brick red (natural)
Tonality® Nuance
70020 Brick red (finished surface) 70006 Dark red 70011 Copper red 70009 Bright red
70016 Sand 70004 Cream 70018 White matt 70022 White glossy
70007 Eggshell 70013 Light grey 70008 Bright grey 70014 Middle grey
70005 Dark grey 70001 Anthracite 70025 Black matt 70023 Black glossy
Please note that actual colours may slightly vary in appearance from those shown on the colour chart.*Graffiti Protection is offered on all colours except Tonality Brick Red (Natural)
GRAFFITIPROTECTION
13
Colour Chart Tonality®
Available surface options | smooth
grooved one pilaster stripe
Tonality® Noblesse Color
70355 – BL1 70356 – BL2 70357 – BL3 70358 – BL4
70380 – GR1 70381 – GR2 70382 – GR3 70383 – GR4
70370 – TU1 70371 – TU2 70372 – TU3
70390 – VI1 70391 – VI2 70392 – VI3
70365 – GE1 70366 – GE2
70375 – OK1 70376 – OK2
70350 – CR1 70351 – CR2 70352 – CR3
70360 – OR1 70361 – OR2
70385 – RO1 70386 – RO2
70340 – BR1 70341 – BR2
Please note that actual colours may slightly vary in appearance from those shown on the colour chart.* Graffiti Protection is offered on all colours.
GRAFFITIPROTECTION
14
Cladding tile tonality®
TONALITY® cladding tiles have
represented highest quality, frost
resistance and durability for decades
now.
The unique variety of colors with select
surfaces, the outstandingly attractive
joint design, and the consumer
oriented installation constitute the
distinguishing features of the high
quality cladding tiles TONALITY®.
The suspended back vented
façade of TONALITY® cladding tiles
proved to be a reliable system with
desirable building characteristics for
new building projects as well as for
renovations of existing buildings.
TONALITY® Classic Natural
TONALITY® Classic Finished Surface
TONALITY® Classic Special Series
TONALITY® Color
TONALITY® Color Natural Red FR3
TONALITY® Sun Protection
All notes and information, technical and graphic instructions, correspond to the current codes and standards of technology, as well as to our experiences based on this technology. The described applications represent examples and do not take into consideration custom designs and circumstances of individual cases. The information and the suitability of the material for the intended purposes must be examined with regard to the respective building project at any rate. Liability is excluded. This shall also apply to misprints and later changes of technical data.
15
Tonality® ADS Fixing SystemApplicationsThe Tonality Adaptive System (ADS) can be fastened on a horizontal or vertical primary substructure. This system is the preferred option for large surfaces and complex facades.
The primary substructure is subject to structural analysis suited to the respective building project and does not constitute a component of the Tonality® system range.
1 Tonality® Cladding tile
2 Tonality® Adaptive vertical profile aluminium
3 Tonality® Adaptive joint profile aluminium
4 Tonality® Protection against dismantling
5 Primary substructure aluminium L -profile
6 Primary substructure aluminium wall fastening
Open
joint profile
Closed
joint profile
16
17
Tonality® Sun ProtectionTonality sun protection systems are an enchanting accent to any building facade.Essentially, the addition of long linear elements to the building surface is a clever way to achieve artistic shading and to create depth.
More importantly, they also provide an effective means of protection from the intense ultraviolet rays of the sun. In summer months, heat gain through an unprotected glass can drive energy costs.Sunscreens can not only combat this phenomenon but, enhance the aesthetic appeal of the exterior elevation.
The Tonality sun protections are offered in three distinct shapes: lamella, baguette and squares.Each design creates a unique look and is offered in a variety of natural colours.
Lamella Tile
Tile height : 260 mm / 150 mm Tile
Baguette Tile
Tile height : 150 mm
Square-shaped Quadrat
Tile height : 40 mm / 50 mm / 70 mm
18
PRODUCT OVERVIEW
MaRS, Toronto ON – B+H Architects
19
ECONOMICAL ADVANTAGES • Shortconstructionperiodsasaresultofahighdegreeofprefabrication• Installationcarriedoutirrespectiveofweatherconditions• Scaffoldingrequiredtobeinplaceonlyforshortperiods• Simplecompensationofthebuildingtolerancespossible• Time-savinginstallationresultingfromstandardizedfasteningsystems• Simpleexchangeofindividualtiles• Durablematerial
POSSIBILITIES OF DESIGN• Individualplanningasaresultoftileformatsfrom150x300mmupto400x1,600mm• Individualplanningasaresultofcolorvarietyandwideproductrange• Colorandmaterialcombinationsarepossible• Coloredaccentuationofthejointispossible• Surfaces:smooth,grooved,pilasterstrip• Customtilesareavailable
ECOLOGICAL ADVANTAGES• High-qualityreuse• EnvironmentalManagingSystemDINENISO14000• Dismantlingwithsortedseparationofmaterialspossible• Materialrecyclinginthecourseoftheproductionprocess
ADAPTIVE SYSTEM (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum T-profile6 Primary sub-construction aluminum wall fastening
The primary sub-construction is subject tostructural analysis suited to the respectivebuilding project and does not constitute a componentof the TONALITY® system range.Details: page 25
Product Overview
Closed joint profile,
joint 8 mm
Open joint profile,
joint 8 mm
End profile for border,
no dismantling
protection
Closed, “not visible”
joint profile joint 2 mm
20
TONALITY® CLASSIC SERIES
The Data Centre, Toronto ON – WZMH & Urbacon
21
TONALITY® CLASSIC NATURAL AND CLASSIC FINISHED SURFACE WITH GRAFFITI PROTECTION*
Material: high-quality kinds of clay, burnt at over 1,200°C, Keralis procedure*Graffiti protection not available on all coloursColors: page 10 & 11Classification of fire resistance: A1 (DIN EN 13501-1)Application: Suspended back-vented façade for all kinds of buildings and building heights, as well as for interior design.Fastening: system-specific for the Adaptive System (ADS)
The TONALITY® Classic Finished Surface range includes a lasting graffiti protection. The protection is effective as of the
first day, i.e. already in the building phase. The freshening up or renewal of the protection required for conventional systems is not necessary here.
DELIVERY RANGETONALITY®
Max. module size (mm)
Module height(mm)
Tile height(mm)
Tolerance(mm)
Module width(mm)
Tile width(mm)
Tolerance(mm)
150 x 900 150 158 ± 2.0 900
Module width– joint width
± 1.0
175 x 900 175 183 ± 2.0 900 ± 1.0
200 x 1,600 200 208 ± 2.0 1,600 ± 1.0
225 x 1,600 225 233 ± 2.0 1,600 ± 1.0
250 x 1,600 250 258 ± 2.0 1,600 ± 1.0
300 x 1,600 300 308 ± 2.0 1,600 ± 1.0
400 x 1,600 400 408 ± 2.0 1,600 ± 1.0
SURFACEExecution smooth Execution grooved Execution pilaster strip
Product Overview
22
TONALITY® LAMELLE TILES
Kreiskrankenhaus in Buchen, Germany (foto Dietmar Strau SS, Besigheim )
23
TONALITY® BAGUETTE AND LAMELLE TILES, SQUARE-SHAPED QUADRAT
Material: high-quality kinds of clay, burnt at 1,200°C, Keralis procedureSurface: natural, without coatingColors: brick red (natural)Application: Privacy and sun protectionFastening: Due to the extremely different requirements, the fastening must be designed specifically
DELIVERY RANGE LAMELLELamelle
Trimmed size (mm) d x b Tile height (mm)
Lamelle 1: 60 x 450 260
Lamelle 2: 50 x 450 150
DELIVERY RANGE BAGUETTEBaguette
Trimmed size (mm) d x b Tile height (mm)
Baguette 65 x 450 150
DELIVERY RANGE SQUARE-SHAPED QUADRATQuadrat
Trimmed size (mm) d x b Tile height (mm)
Quadrat 1: 40 x 450 40
Quadrat 2: 50 x 450 50
Quadrat 3: 70 x 450 70
Product Overview
Lamelle 1 Lamelle 2 2 (special color)
24
TONALITY® CLASSIC SERIES
Fortinos, Stoney Creek ON – Turner Fleischer Architects
25
TONALITY® SYSTEM SUB-CONSTRUCTION ADAPTIVE SYSTEM ON METAL SUB-CONSTRUCTION
The TONALITY® Adaptive System (ADS) can be fastened on a horizontal or vertical pri-mary sub-construction. The vertical profiles of the TONALITY® Adaptive System can take joint profiles with closed, fine or open end profiles without joint. Miter cut corners require the use of the external corner profiles available for the left and right side, in the 3 system depths of 46, 56 and 66 mm. In the event of open corners with profiles and a system depth of 56 and 66 mm, the installation requires the use of the TONALITY® external corner profile of 30 x 30 mm. The TONALITY® supporting profile prevents the generation of noise in the agraffe retainers. Reveal/lintel profiles are available for the fastening in the area of windows and doors. Bias-cut tiles are fixed using TONALITY® gable clamps with special glue.
Choice of profile Tile height (mm) Profile length (mm)
The agraffe retainers producedifferent profiles and profilelengths of the sub-constructionas a result of the respectivetile height
150 2,694
175 2,794
200 2,794
225 2,694
250 2,744
300 2,694
400 2,794
DELIVERY RANGEIllustration Description Color / Material
TONALITY® Adaptive Vertical Profile 4635 x 60 x 35 mm forsystem depth 46 mm
SemimachinedAluminum
TONALITY® Adaptive Vertical Profile 5645 x 60 x 45 mm forsystem depth 56 mm
SemimachinedAluminum
TONALITY® Adaptive Vertical Profile 6655 x 60 x 55 mm forsystem depth 66 mm
SemimachinedAluminium
TONALITY® Joint profile closed(8 mm) 56 x 23 mmfor all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Joint profile closed(8 mm) 56 x 30 mm, flush
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Joint profile open56 x 31mm
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Joint profile “Fine Joint”(2 mm) 56 x 23 mmfor all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Joint profile “Fine Joint”(2 mm) 56 x 30 mm, flush
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Reveal/lintel profilenarrow, profile width 40 mm
for all system depths
SemimachinedAluminium
TONALITY® Reveal/lintel profilewide, profile width 100 mm
for all system depths
SemimachinedAluminium
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Illustration Description Color / Material
TONALITY® Vertical profile external corner46, 74 / 35 mm, usable on both sides
for system depth 46 mm
SemimachinedAluminum
TONALITY® Vertical profile external corner56, 74 / 35 mm, usable on both sides
for system depth 56 mm
SemimachinedAluminum
TONALITY® Vertical profile external corner66, 74 / 45 mm, usable on both sides
for system depth 66 mm
SemimachinedAluminium
TONALITY® End profile for border56 x 5 mm
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Supporting profile 60 mmFor all system depths and modules
RAL 7021(blackgray)Aluminium
TONALITY® External corner profile 30 x 30mm, For all modules with system depth
56 / 66 mm
RAL 7021(blackgray)Aluminium
TONALITY® Gable clampsFor all system depths and modules
RAL 7021(blackgray)Aluminium
Glue for gable clampsConsumption:
1 cartridge for 30 clamps
RAL 7021(blackgray)Aluminium
Sealing gasket profilefor wind barrier 27 x 64 mm
SemimachinedAluminium
Joint profile (wind barrier)8 / 17 mm
SemimachinedAluminium
Aluminium quality EN AW 5754 according to DIN EN 755-2
26
ADAPTIVE SYSTEM ON HORIZONTAL SUB-CONSTRUCTION
ADAPTIVE SYSTEM ON VERTICAL SUB-CONSTRUCTION
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Adaptive system (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile
aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum L-profile6 Primary sub-construction aluminum wall
fastening
The primary sub-construction is subject to structural analysis suited to the respective building project and does not constitute a component of the TONALITY® system range.
Adaptive system (ADS)1 TONALITY® Cladding tile2 TONALITY® Adaptive vertical profile
aluminum3 TONALITY® Adaptive joint profile aluminum4 TONALITY® Protection against dismantling5 Primary sub-construction aluminum T-profile6 Primary sub-construction aluminum wall
fastening
The primary sub-construction is subject to structural analysis suited to the respective building project and does not constitute a component of the TONALITY® system range.
Primary sub-constructionDistances, kinds of brackets and plugs, as well as rivets resp. drilling screws are subject to structural calculation for the respective building project!
TONALITY® Adaptive System
27
CALCULATION VALUES
Profile depth/system depth
17 mm / 46 mm 27 mm / 56 mm 37 mm / 66 mm
Cross-sectional area
1.72 cm2 2.12 cm2 2.52 cm2
Moment of inertia ly = 0.28 cm4lz = 7.97 cm4
ly = 1.22 cm4lz = 11.34 cm4
ly = 3.13 cm4lz = 14.71 cm4
Moment of resistance
Wyo = 0.24 cm3Wyu = 0.86 cm3Wyz = 2.66 cm3
Wyo = 0.66 cm3Wyu = 1.90 cm3Wyz = 3.78 cm3
Wyo = 1.26 cm3Wyu = 3.08 cm3Wyz = 4.90 cm3
DETAIL ROOF PARAPET EDGE, DETAIL BASE JOINT - ADAPTIVE SYSTEM
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations
The external vertical side of coverings or edge profiles should overlap the upper edge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm
The height of roof edge borders should be approx. 100 mm with roof pitches of up to 5° approx. 50 mm with roof pitches > 5° above the covering surface resp. gravel layer.Roof edge borders must have an inclination towards the roof side.
The projection of coverings or edge profiles must maintain a drip edge of at least 20 mm distance from the building components to be protected.
18 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations
The external vertical side of coverings oredge profiles should overlap the upperedge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm
The height of roof edge borders should beapprox. 100 mm with roof pitches of up to 5°approx. 50 mm with roof pitches > 5°above the covering surface resp. gravellayer.Roof edge borders must have an inclina-tion towards the roof side. The projection of coverings or edge pro-files must maintain a drip edge of at least20 mm distance from the building compo-nents to be protected.
Detail Roof Parapet Edge, Detail Base Joint - Adaptive System
SYSTEM CONSTRUCTION AND STANDARD DETAILS
H 1
H 1
H 2
H 2
T
T
Maßstab ca. 1:10
Calculation valuesProfile depth/system depth
Cross-sectional area
Moment of inertia
Moment of resistance
17 mm / 46 mm
1.72 cm2
ly = 0.28 cm4
lz = 7.97 cm4
Wyo = 0.24 cm3
Wyu = 0.86 cm3
Wyz = 2.66 cm3
27 mm / 56 mm
2.12 cm2
ly = 1.22 cm4
lz = 11.34 cm4
Wyo = 0.66 cm3
Wyu = 1.90 cm3
Wyz = 3.78 cm3
37 mm / 66 mm
2.52 cm2
ly = 3.13 cm4
lz = 14.71 cm4
Wyo = 1.26 cm3
Wyu = 3.08 cm3
Wyz = 4.90 cm3
E-module = 70,000 N/mm2, acc. to DIN 4113-1
Profile depth System depth
18Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 18
SYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
H1
H2
T
E-module = 70,000 N/mm2, acc. to DIN 4113-1
18 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Adaptive System (ADS)Vertical section roof parapetRequirements acc. to pitched roof regulations
The external vertical side of coverings oredge profiles should overlap the upperedge of the plaster or claddings.Building height:up to 8 m: min. 50 mmover 8 up to 20 m: min. 80 mmover 20 m: min. 100 mm
The height of roof edge borders should beapprox. 100 mm with roof pitches of up to 5°approx. 50 mm with roof pitches > 5°above the covering surface resp. gravellayer.Roof edge borders must have an inclina-tion towards the roof side. The projection of coverings or edge pro-files must maintain a drip edge of at least20 mm distance from the building compo-nents to be protected.
Detail Roof Parapet Edge, Detail Base Joint - Adaptive System
SYSTEM CONSTRUCTION AND STANDARD DETAILS
H 1
H 1
H 2
H 2
T
T
Maßstab ca. 1:10
Calculation valuesProfile depth/system depth
Cross-sectional area
Moment of inertia
Moment of resistance
17 mm / 46 mm
1.72 cm2
ly = 0.28 cm4
lz = 7.97 cm4
Wyo = 0.24 cm3
Wyu = 0.86 cm3
Wyz = 2.66 cm3
27 mm / 56 mm
2.12 cm2
ly = 1.22 cm4
lz = 11.34 cm4
Wyo = 0.66 cm3
Wyu = 1.90 cm3
Wyz = 3.78 cm3
37 mm / 66 mm
2.52 cm2
ly = 3.13 cm4
lz = 14.71 cm4
Wyo = 1.26 cm3
Wyu = 3.08 cm3
Wyz = 4.90 cm3
E-module = 70,000 N/mm2, acc. to DIN 4113-1
Profile depth System depth
18Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 18
SYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
28
DETAIL ExTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM ON VERTICAL SUBCONSTRUCTION
Cladding tile tonality® 19
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
DETAIL ExTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM ON HORIZONTAL SUBCONSTRUCTION
Cladding tile tonality® 19
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
Cladding tile tonality® 19
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
Cladding tile tonality® 19
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
DETAIL INTERNAL CORNER OF BUILDING – ADAPTIVE SYSTEM
Cladding tile tonality® 19
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical pri-mary sub-construction.A) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical pro-file is effected on an aluminum bracket.B) External corner: TONALITY® with corner pro-
file– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile
The fixation of the vertical profile is effected onan aluminum bracket.
Detail External Corner of Building – Adaptive System on Vertical Sub-Construction
Detail External Corner of Building – Adaptive System on Horizontal Sub-Construction
A B
C D E
Detail Internal Corner of Building – Adaptive System
Internal corner 90° with adaptive system end profile
External corner 90° - TONALITY® on horizontalprimary sub-construction.C) External corner: TONALITY® with miter cut
– Vertical profile external corner 45 x 74– Supporting profile
In case of miter cut, the edges must have abevel of 4 mm.D) External corner: TONALITY® with corner profile
– Vertical profile external corner 45 x 74– Supporting profile– Visible external corner profile (anodized
E6EV1 / semimachined)
E) External corner: TONALITY® with verticalwind barrier for reduced wind pressureaccording to DIN 1055-4:2005-03
19Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 19
SYSTEM CONSTRUCTION AND STANDARD DETAILS
External corner 90° - TONALITY® on vertical primary sub-construction.A) External corner: TONALITY® with miter cut – Vertical profile external corner 45 x 74 – Supporting profileIn case of miter cut, the edges must have abevel of 4 mm. The fixation of the vertical profileis effected on an aluminum bracket.B) External corner: TONALITY® with corner profile – Vertical profile external corner 45 x 74 – Supporting profile – Visible external corner profileThe fixation of the vertical profile is effected onan aluminum bracket.
External corner 90° - TONALITY® on horizontal primary sub-construction.C) External corner: TONALITY® with miter
cut – Vertical profile external corner
45 x 74 – Supporting profile
In case of miter cut, the edges must have a bevel of 4 mm.D) External corner: TONALITY® with
corner profile – Vertical profile external corner
45 x 74 – Supporting profile – Visible external corner profile
(anodized E6EV1 / semimachined)
Internal corner 90° with adaptivesystem end profile
E) External corner: TONALITY® with vertical wind barrier for reduced wind pressure according to DIN 1055-4:2005-03
29
DETAIL WINDOW – ADAPTIVE SYSTEM
20 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Detail Window – Adaptive System
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Vertical sectionWindow, lintel and parapet
A) without sun protection
B) with integrated sun protection
C) parapet of cladding tiles
Maßstab ca. 1:5
Horizontal sectionWindow reveal with vertical primary sub-con-struction.
Horizontal sectionWindow reveal with horizontal primary sub-con-struction.
Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.
Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.
A
B C
20Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Vertical sectionWindow, lintel and parapet
A) without sun protection
B) with integrated sun protection
C) parapet of cladding tiles
Horizontal sectionWindow reveal with vertical primary sub-construction.
Horizontal sectionWindow reveal with horizontal primary sub-construction.
Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.
Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construction
30
ADAPTIVE PIECE ADDITIONAL SUPPORT
Cladding tile tonality® 21
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Detail Window – Adaptive System
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Vertical sectionWindow, lintel and parapet
A) without sun protection
B) with integrated sun protection
C) parapet of cladding tiles
Maßstab ca. 1:5
Horizontal sectionWindow reveal with vertical primary sub-con-struction.
Horizontal sectionWindow reveal with horizontal primary sub-con-struction.
Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.
Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.
A
B C
20Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20
Detail – Window Fitting Tile with Adapter Piece or Gable Clamp for Adaptive System
Adaptive Piece Additional Support
SYSTEM CONSTRUCTION AND STANDARD DETAILS
A B
C D
A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptivesystem. Fastening pinned from the back onto the profile of the adaptive system.
21Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 21
The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptive system. Fastening pinned from the back onto the profile of the adaptive system.
DETAIL – WINDOW FITTING TILE WITH ADAPTER PIECE OR GABLE CLAMP FOR ADAPTIVE SYSTEM
Cladding tile tonality® 21
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Detail Window – Adaptive System
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Vertical sectionWindow, lintel and parapet
A) without sun protection
B) with integrated sun protection
C) parapet of cladding tiles
Maßstab ca. 1:5
Horizontal sectionWindow reveal with vertical primary sub-con-struction.
Horizontal sectionWindow reveal with horizontal primary sub-con-struction.
Horizontal sectionWindow reveal of cladding tiles with revealclamp.Tile length up to max. 150 mm.
Horizontal sectionWindow reveal of cladding tiles with reveal /lintel profile on vertical primary sub-construc-tion.
A
B C
20Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 20
Detail – Window Fitting Tile with Adapter Piece or Gable Clamp for Adaptive System
Adaptive Piece Additional Support
SYSTEM CONSTRUCTION AND STANDARD DETAILS
A B
C D
A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
The adaptive piece is used in connection with horizontally slit fitting tile. A second mounting possibility must be given on the profile of the adaptivesystem. Fastening pinned from the back onto the profile of the adaptive system.
21Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:01 Uhr Seite 21SYSTEM CONSTRUCTION AND STANDARD DETAILS
A) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
B) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
C) Vertical sectionAdapter piece for tile segments with at leasttwo mounting agraffes
D) Vertical sectionPediment clamp for tile segments with only onemounting agraffes
31
TONALITY SYSTEM SUB-CONSTRUCTION OF ADAPTIVE SYSTEM ON WOODEN SUB-CONSTRUCTION
32 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
SYSTEM CONSTRUCTION AND STANDARD DETAILS
TONALITY® System Sub-Construction of Adaptive, Base Clinch Rail and Classic Profile Systemson Wooden Primary Sub-Construction
1
2
3
4
5
System structure of the Adaptive System
Adaptive System on horizontal wooden sub-construction
Base Clinch Rail Profile on vertical wooden sub-construction
1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive
System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile
1
2
3
4
1
2
3
5
4
System structure of the Base Clinch Rail System
System structure of the Classic Profile System
1 Wooden sub-construction2 Profile of the TONALITY® Base Clinch Rail
System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile
1 Wooden sub-construction2 Profile of the TONALITY® Classic Profile
System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile5 Joint profile of the Classic Profile System
32Planning & Application 2009 Cladding tiles TONALITY®
The installation of the Classic Profile System on a wooden sub-construction is possible as well.
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 32
32 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
SYSTEM CONSTRUCTION AND STANDARD DETAILS
TONALITY® System Sub-Construction of Adaptive, Base Clinch Rail and Classic Profile Systemson Wooden Primary Sub-Construction
1
2
3
4
5
System structure of the Adaptive System
Adaptive System on horizontal wooden sub-construction
Base Clinch Rail Profile on vertical wooden sub-construction
1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive
System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile
1
2
3
4
1
2
3
5
4
System structure of the Base Clinch Rail System
System structure of the Classic Profile System
1 Wooden sub-construction2 Profile of the TONALITY® Base Clinch Rail
System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile
1 Wooden sub-construction2 Profile of the TONALITY® Classic Profile
System3 Rivet / drilling screw / woodscrew4 TONALITY® Cladding tile5 Joint profile of the Classic Profile System
32Planning & Application 2009 Cladding tiles TONALITY®
The installation of the Classic Profile System on a wooden sub-construction is possible as well.
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 32
Adaptive System on horizontal wooden sub-construction
Detail Internal Corner of Building – Wooden Primary Sub-Construction
Cladding tile tonality® 33
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
Detail External Corner of Building – Wooden Primary Sub-Construction
Horizontal sectionExternal corner with external corner profile
Horizontal sectionExternal corner with miter cut
Detail Internal Corner of Building – Wooden Primary Sub-Construction
Horizontal sectionInternal corner
Detail Window – Wooden Primary Sub-Construction
Horizontal sectionWindow reveal with metal frame on wooden sub-construction
Vertical sectionWindow sill connection onwooden sub-construction
30
33Planning & Application 2009 Cladding tiles TONALITY®
wooden substructure 80x60insolation 60 mm
wooden substructure 80x60
TONALITY cladding element
vertical profil for external corner
done byinstaller
not restriced ventilation
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 33
Detail Window – Wooden Primary Sub-Construction
Cladding tile tonality® 33
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
Detail External Corner of Building – Wooden Primary Sub-Construction
Horizontal sectionExternal corner with external corner profile
Horizontal sectionExternal corner with miter cut
Detail Internal Corner of Building – Wooden Primary Sub-Construction
Horizontal sectionInternal corner
Detail Window – Wooden Primary Sub-Construction
Horizontal sectionWindow reveal with metal frame on wooden sub-construction
Vertical sectionWindow sill connection onwooden sub-construction
30
33Planning & Application 2009 Cladding tiles TONALITY®
wooden substructure 80x60insolation 60 mm
wooden substructure 80x60
TONALITY cladding element
vertical profil for external corner
done byinstaller
not restriced ventilation
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 33
SYSTEM CONSTRUCTION AND STANDARD DETAILS
System structure of the Adaptive System1 Wooden sub-construction2 Vertical profile of the TONALITY® Adaptive System3 Rivet / drilling screw / woodscrew4 Joint profile of TONALITY® Adaptive System5 TONALITY® Cladding tile
Horizontal sectionInternal corner
Horizontal sectionWindow reveal with metal frame onwooden sub-construction
Vertical sectionWindow sill connection onwooden sub-construction
32
TONALITY® ADAPTIVE SYSTEM T-LINE®
SYSTEM CONSTRUCTION AND STANDARD DETAILS
The TONALITY® System sub-construction T-Lineallows to create the classic appearance ofbrickwork. It is suitable for all kinds of tiles andtile sizes. As an adaptive system, T-Line can berealized on vertical as well as on horizontalsub-constructions.
The TONALITY® Adaptive System T-Line consistsof type A and type B profiles that are fastenedalternately on the primary sub-construction.Type A and type B joint profiles are available asjoint profile with a closed joint of 8 mm.
34 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
TONALITY® Adaptive System T-Line®
The TONALITY® System sub-construction T-Lineallows to create the classic appearance ofbrickwork. It is suitable for all kinds of tiles andtile sizes. As an adaptive system, T-Line can berealized on vertical as well as on horizontalsub-constructions.
The TONALITY® Adaptive System T-Line consistsof type A and type B profiles that are fastenedalternately on the primary sub-construction.Type A and type B joint profiles are available asjoint profile with a closed joint of 8 mm.
34Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 34
33
TONALITY® ADAPTIVE SYSTEM T-LINE®
Cladding tile tonality® 35
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
TONALITY® Adaptive System T-Line
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Delivery range: Illustration Description
TONALITY® T-Line vertical profile type A35 x 60 x 35 mm
system depth 46 mm
TONALITY® T-Line vertical profile type A45 x 60 x 45 mm
system depth 56 mm
TONALITY® T-Line vertical profile type A55 x 60 x 55 mm
system depth 66 mm
TONALITY® T-Line joint profile type Aclosed 8 mm56 x 23 mm
Color / Material
SemimachinedAluminium
SemimachinedAluminium
SemimachinedAluminium
RAL 7021(blackgray)Aluminium
Illustration Description
TONALITY® T-Line vertical profile type B35 x 60 x 35 mm
system depth 46 mm
TONALITY® T-Line vertical profile type B45 x 60 x 45 mm
system depth 56 mm
TONALITY® T-Line vertical profile type B55 x 60 x 55 mm
system depth 66 mm
TONALITY® T-Line joint profile type Bclosed 8 mm56 x 23 mm
Color / Material
SemimachinedAluminium
SemimachinedAluminium
SemimachinedAluminium
RAL 7021(blackgray)Aluminium
Aluminium quality = EN AW 5754 according to DIN EN 755-2
35Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 35
DELIVERY RANGE:
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Illustration Description Color / Material
TONALITY® T-Line vertical profile type A35 x 60 x 35 mm
system depth 46 mm
SemimachinedAluminum
TONALITY® T-Line vertical profile type A45 x 60 x 45 mm
system depth 56 mm
SemimachinedAluminum
TONALITY® T-Line vertical profile type A55 x 60 x 55 mm
system depth 66 mm
SemimachinedAluminium
TONALITY® T-Line joint profile type Aclosed 8 mm56 x 23 mm
RAL 7021(blackgray)Aluminium
Illustration Description Color / Material
TONALITY® T-Line vertical profile type B35 x 60 x 35 mm
system depth 46 mm
SemimachinedAluminum
TONALITY® T-Line vertical profile type B45 x 60 x 45 mm
system depth 56 mm
SemimachinedAluminum
TONALITY® T-Line vertical profile type B55 x 60 x 55 mm
system depth 66 mm
SemimachinedAluminium
TONALITY® T-Line joint profile type Bclosed 8 mm56 x 23 mm
RAL 7021(blackgray)Aluminium
34
TONALITY® ADAPTIVE SYSTEM SIDING®
SYSTEM CONSTRUCTION AND STANDARD DETAILS
The TONALITY® Siding sub-construction is perfectly suitable for the design of a TONALITY® cladding tile façade with the appearance of weatherboarding.
The realization of this TONALITY® system subconstruction allows for the use of all kinds of tiles and tile sizes.
The inclined position and the overlapping of the TONALITY® tiles result from the shape of the profiles of the TONALITY® system sub-construction. The continuous vertical joints can be designed as a closed joint of 8 mm or as a fine joint of 2 mm, as well as flush or set back with regard to the front edge of the tile.
36 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
Adaptive System TONALITY® SIDING®
The TONALITY® Siding sub-construction is per-fectly suitable for the design of a TONALITY®
cladding tile façade with the appearance ofweatherboarding.The realization of this TONALITY® system sub-construction allows for the use of all kinds oftiles and tile sizes.The inclined position and the overlapping of theTONALITY® tiles result from the shape of theprofiles of the TONALITY® system sub-construc-tion.The continuous vertical joints can be designedas a closed joint of 8 mm or as a fine joint of 2mm, as well as flush or set back with regard tothe front edge of the tile.
36Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 36
36 Cladding tile tonality®
SYSTEMCONSTRUCTIONANDSTANDARDDETAILSSYSTEM CONSTRUCTION AND STANDARD DETAILS
Adaptive System TONALITY® SIDING®
The TONALITY® Siding sub-construction is per-fectly suitable for the design of a TONALITY®
cladding tile façade with the appearance ofweatherboarding.The realization of this TONALITY® system sub-construction allows for the use of all kinds oftiles and tile sizes.The inclined position and the overlapping of theTONALITY® tiles result from the shape of theprofiles of the TONALITY® system sub-construc-tion.The continuous vertical joints can be designedas a closed joint of 8 mm or as a fine joint of 2mm, as well as flush or set back with regard tothe front edge of the tile.
36Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 36
35
TONALITY® ADAPTIVE SYSTEM SIDING®
DELIVERY RANGE:
Aluminium quality = EN AW 5754 according to DIN EN 755-2
Cladding tile tonality® 37
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Adaptive System TONALITY® SIDING®
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Horizontal section external corner of building - Siding
tile length
axis
"TONALITY® "-adaptive end lug 56x5
"TONALITY® "-SIDING vertical profile
8
vertical supportalu metal sheet,by contractor
4 4
"TONALITY® "cladding tile
219
60
"TON
ALITY®
"cl
addi
ng ti
le
2 19
unre
stric
ted
vent
ilatio
n
varia
bel
syst
em d
epth
66
44intermediate inset
fitting piecefor tile sections
with at least tworestoring pins
see ANo. dwg 746
19 46
e.g. system depth 66
unre
strict
edve
ntila
tion
12
12
journal as partof the standardcarrier systemSID
lower hookmay beturned aroundor cut off forconvencience
36
Horizontal section internal corner of building - Siding Vertical section window, lintel and parapet - Siding
fitted tile
journal as partof the standardcarrier systemSID
intermediate insetfitting piece
for tile sectionswith at least two
restoring pinssee ANo. dwg 746
lower hookmay beturned aroundor cut off forconvencience
Delivery range: Illustration Description
TONALITY® Siding vertical profile50 x 60 x 50 mm
for system depth 66 mm
TONALITY® Siding vertical profile60 x 60 x 60 mm
for system depth 76 mm
TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm
for all system depths
TONALITY® Siding joint profileClosed, flush, 8 mm
56 x 48 mm, for all system depths
Color / Material
MachinedAluminium
MachinedAluminium
RAL 7021(blackgray)Aluminium
RAL 7021(blackgray)Aluminium
Illustration Description
TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm
for all system depths
TONALITY® Siding joint profile“Fine joint”, 2 mm, flush
56 x 48 mm for all profile depths
TONALITY® Siding external corner profile57 x 57 mm for system depths
66 mm and 76 mm
TONALITY® Siding adapter piece50 x 45 mm
for all system depths
Color / Material
RAL 7021(blackgray)Aluminium
RAL 7021(blackgray)Aluminium
Aluminium
SemimachinedAluminium
Aluminium quality = EN AW 5754 according to DIN EN 755-2
37Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 37
Horizontal section external corner of building - Siding
Cladding tile tonality® 37
SYSTEMCONSTRUCTIONANDSTANDARDDETAILS
Adaptive System TONALITY® SIDING®
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Horizontal section external corner of building - Siding
tile length
axis
"TONALITY® "-adaptive end lug 56x5
"TONALITY® "-SIDING vertical profile
8
vertical supportalu metal sheet,by contractor
4 4
"TONALITY® "cladding tile
219
60
"TON
ALITY®
"cl
addi
ng ti
le
2 19
unre
stric
ted
vent
ilatio
n
varia
bel
syst
em d
epth
66
44
intermediate insetfitting piece
for tile sectionswith at least two
restoring pinssee ANo. dwg 746
19 46
e.g. system depth 66
unre
strict
edve
ntila
tion
12
12
journal as partof the standardcarrier systemSID
lower hookmay beturned aroundor cut off forconvencience
36
Horizontal section internal corner of building - Siding Vertical section window, lintel and parapet - Siding
fitted tile
journal as partof the standardcarrier systemSID
intermediate insetfitting piece
for tile sectionswith at least two
restoring pinssee ANo. dwg 746
lower hookmay beturned aroundor cut off forconvencience
Delivery range: Illustration Description
TONALITY® Siding vertical profile50 x 60 x 50 mm
for system depth 66 mm
TONALITY® Siding vertical profile60 x 60 x 60 mm
for system depth 76 mm
TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm
for all system depths
TONALITY® Siding joint profileClosed, flush, 8 mm
56 x 48 mm, for all system depths
Color / Material
MachinedAluminium
MachinedAluminium
RAL 7021(blackgray)Aluminium
RAL 7021(blackgray)Aluminium
Illustration Description
TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm
for all system depths
TONALITY® Siding joint profile“Fine joint”, 2 mm, flush
56 x 48 mm for all profile depths
TONALITY® Siding external corner profile57 x 57 mm for system depths
66 mm and 76 mm
TONALITY® Siding adapter piece50 x 45 mm
for all system depths
Color / Material
RAL 7021(blackgray)Aluminium
RAL 7021(blackgray)Aluminium
Aluminium
SemimachinedAluminium
Aluminium quality = EN AW 5754 according to DIN EN 755-2
37Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 37
Horizontal section external corner of building - Siding Vertical section window, lintel and parapet - Siding
SYSTEM CONSTRUCTION AND STANDARD DETAILS
Illustration Description Color / Material
TONALITY® Siding vertical profile50 x 60 x 50 mm
for system depth 66 mm
MachinedAluminum
TONALITY® Siding vertical profile60 x 60 x 60 mm
for system depth 76 mm
MachinedAluminum
TONALITY® Siding joint profileclosed 8 mm, 56 x 36 mm
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Siding joint profileClosed, flush, 8 mm
56 x 48 mm, for all system depths
RAL 7021(blackgray)Aluminium
Illustration Description Color / Material
TONALITY® Siding joint profile“Fine joint”, 2 mm, 56 x 36 mm
for all system depths
RAL 7021(blackgray)Aluminium
TONALITY® Siding joint profile“Fine joint”, 2 mm, flush
56 x 48 mm for all profile depths
RAL 7021(blackgray)Aluminium
TONALITY® Siding external corner profile57 x 57 mm for system depths
66 mm and 76 mmAluminium
TONALITY® Siding adapter piece50 x 45 mm
for all system depths
SemimachinedAluminium
36
CLAY AS A RAW MATERIALAs a raw material, clay has been well known since Antiquity. And ever since the discovery of clay ceramics about 10,000 - 8,000 BC, the popularity of clay is based on the exceptional plasticity of wet clays. Thus, clay represents one of the oldest natural raw materials of our days. Clays are weathering and erosion products of the Earth’s crust. They occur
in the continental and maritime area. Their variety depends on the physical and chemical conditions prevailing at the time of their formation. These conditions allow for a broad spectrum of characteristics and thus for the broad possibilities of application of clays. The quality clays used to manufacture the TONALITY® productsquarried in the Westerwald area of
Germany. These clays are considered to be among the best kinds of clay worldwide and are known for their particular purity.TONALITY® cladding tiles show a profile on the reverse and are attached onto vertical support frames made of aluminum by means of positive locking.
MANUFACTURING PROCEDURETONALITY® cladding tiles are manufactured in ultra-modern production plants using a vacuum extrusion method, dried and burnt. In the course of the patented Keralis procedure, the raw material clay is dried, processed into finest powdered clay and completely dyed in finely graduated ratios of color mixtures.
The products are subsequently burnt at temperatures of approx. 1,200°C.A sintering process will take place in the course of the baking as a result of the processing of highquality raw materials and the high baking temperature. This sintering allows for the impermeabilityand the smooth surface. The production
of the TONALITY® cladding tiles is taking place in the production plants of the manufacturer CREATON in accordance with DIN EN ISO 9001 Quality Management System and DIN EN ISO 14000 Environmental Management System.
CHARACTERISTICS Non-combustible
(Building Material Class A1) Weather and frost-resistant Waterproof Rot-resistant
Resistant to UV-light Shockproof Classic Finished Surface and optionally Color with permanent graffiti protection
Low weight of the system of less than 35 kg/m2
Tight-fitting installation between tile andsystem sub-construction
Installation can be carried out irrespective of weather conditions
AREAS OF APPLICATIONSuspended back-vented cladding. Applicable for external as well as internal walls of any kind of building or building height. A National Technical Approval recorded under No. Z-32.1-
567 in accordance with DIN 18516 of the Deutsches Institut für Bautechnik, a German institute of the Federal and Laender Govern-ments for a uniform fulfillment of technical tasks in the field
of public law, can be presented for the TONALITY® cladding system. In addition, TONALITY® products allow for the design of sun and privacy protections.
SYSTEM ADVANTAGES OF THE SUSPENDED, BACKVENTED FAçADE
38 Cladding tile tonality®
PLANNINGBASESANDPROCESSING
Clay as a raw material
Manufacturing procedure
PLANNING BASES AND PROCESSING
As a raw material, clay has been well knownsince Antiquity. And ever since the discovery ofclay ceramics about 10,000 - 8,000 BC, the popu-larity of clay is based on the exceptional plasticityof wet clays. Thus, clay represents one of the old-est natural raw materials of our days. Clays areweathering and erosion products of the Earth’s
crust. They occur in the continental and maritimearea. Their variety depends on the physical andchemical conditions prevailing at the time of theirformation. These conditions allow for a broadspectrum of characteristics and thus for the broadpossibilities of application of clays. The qualityclays used to manufacture the TONALITY® products
quarried in the Westerwald area of Germany. Theseclays are considered to be among the best kinds ofclay worldwide and are known for their particularpurity.TONALITY® cladding tiles show a profile on thereverse and are attached onto vertical support framesmade of aluminum by means of positive locking.
TONALITY® cladding tiles are manufactured inultra-modern production plants using a vacuumextrusion method, dried and burnt. In the course ofthe patented Keralis procedure, the raw materialclay is dried, processed into finest powdered clayand completely dyed in finely graduated ratios of
color mixtures. The products are subsequentlyburnt at temperatures of approx. 1,200°C.A sintering process will take place in the course ofthe baking as a result of the processing of high-quality raw materials and the high baking temper-ature. This sintering allows for the impermeability
and the smooth surface. The production of theTONALITY® cladding tiles is taking place in the pro-duction plants of the manufacturer CREATON inaccordance with DIN EN ISO 9001 QualityManagement System and DIN EN ISO 14000Environmental Management System.
Characteristics■ Non-combustible
(Building Material Class A1)■ Weather and frost-resistant■ Waterproof■ Rot-resistant
■ Resistant to UV-light■ Shockproof■ Classic Finished Surface and optionally Color
with permanent graffiti protection
■ Low weight of the system of less than 35 kg/m2
■ Tight-fitting installation between tile andsystem sub-construction
■ Installation can be carried out irrespective ofweather conditions
Areas of applicationSuspended back-vented cladding. Applicablefor external as well as internal walls of any kindof building or building height. A National TechnicalApproval recorded under No. Z-32.1-567 in
accordance with DIN 18516 of the DeutschesInstitut für Bautechnik, a German institute ofthe Federal and Laender Govern-ments for auniform fulfillment of technical tasks in the field
of public law, can be presented for the TONALITY®
cladding system. In addition, TONALITY® prod-ucts allow for the design of sun and privacyprotections.
System advantages of the suspended, back-vented façade1 Insulating material2 Ventilation3 Adjustable wall
fastening withthermal separator
4 Supporting profile5 System-specific
sub-construction6 Cladding tile
Diffusion-open construc-tion, prevented moisturepenetration to the wallsand insulation
Each insulation thicknesscan be realized
Protection of buildingcomponents againstweather effects
Building periods can beestimate as installationis carried out irrespec-tive of weather
DisposalCladding tiles can be disposed of as construc-tion and demolition waste under the waste keynumber 17.01.03 (tiles, bricks and ceramicsaccording to the European Waste Catalogue).
The separation of materials allows for theirsupply for high-quality recycling. The aluminumprofiles can be disposed of as reusable materi-al or as construction and demolition waste
under the waste key number 17.04.02(Aluminum according to the European WasteCatalogue).
Storage and transportCladding tiles and sub-construction arepacked on pallets and wrapped with edge pro-
tection in shrink foil in order to prevent dam-age and soiling.
Wall structure with TONALITY® cladding tiles Cladding system with the lowest susceptibility to damage (Rainer Oswald among others: Third Report on Damages to Buildings, Bonn 1998)
38Planning & Application 2009 Cladding tiles TONALITY®
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 38
STORAGE AND TRANSPORTCladding tiles and sub-construction are packed on pallets and wrapped with edge protection in shrink foil in order to prevent damageand soiling.
PLANNING BASICS & INSTALLATION
37
DIN 18516DIN EN 1304
DIN EN 539-2
Action on structuresDIN 1055, Part 1, 4 and 5
Metal worksDIN 18800
DIN 4113, Part 1
Timber structuresDIN 1052, Part 1 to 4
MasonryDIN 1053, Part1
DIN 1045
Thermal insulationDIN 4108, Part 1 to 4
Moisture protection subject to climateconditions DIN EN 13162
Fire protectionDIN EN 13501
Sound insulationDIN 4109
DIN 18005
TolerancesDIN 18202DIN 1960DIN 1961
DIN 4420, Part 1, 2 und 4DIN 18335DIN 18360DIN 18339DIN 18338DIN 18364DIN 18384DIN 18451DIN 18800DIN 18200DIN 52253
Special Regulations of the Roofing TradeCladding for external walls, back-ventedRoofing tiles and fittings, product definitions and specificationsBurnt-clay roofing tiles
Self-weight, wind loads, design loads
Steel structures, design and constructionAluminum construction under predominantly static loading
Timber structures
MasonryConcrete and reinforced and prestressed concrete structures
Thermal insulation in buildings, thermal protection energy economy
Thermal insulation products for buildings
Fire classification of building materials and building components, Fire protection Regulations (BTR)
Sound insulation in buildingNoise abatement in town planning
Dimensional tolerances in building constructionContract procedures for building works, Part AContract procedures for building works, Part BService and working scaffoldsContract procedures for building works, steel construction worksContract procedures for building works, metal construction worksContract procedures for building works, sheet metal worksContract procedures for building works, roof covering and roof sealing worksContract procedures for building works, works for protection of steel structuresLightning protection systemsScaffolding worksSteel structuresAssessment of conformity, building materials, building components, designFrost resistance, Part 1
Fire classification:Bulk density:
Water absorption capacity:Frost resistance:
combustible, A1 (DIN EN 13501-1)2.25 g/cm3< 6%given according to DIN EN 539-2 DIN
STANDARDS, REGULATIONS, APPROVALS
The above listing shows only an excerpt of the regulations and standards to be observed. It does not claim completeness.
TECHNICAL DATA TONALITY®
PLANNING BASICS & INSTALLATION
38
ADAPTIVE SYSTEM (ADS)
Installation of vertical profiles:
The TONALITY® vertical profiles must be screwed resp. riveted to the height and the façade grid of the
already installed sub- construction. The distance between brackets and the kind of fastening must be
effected according to the static requirements of the building. Fixing material admitted for use by the
construction supervising authority must be used at any rate. As already described for the primary sub-
construction, gaps for the linear expansion of profiles must be allowed for at the joints in the course of the
profile installation. It must be paid attention to the fact that the required gap at the joint is executed observing
the same height grid of the primary sub-construction (Tprofile) and of the agraffe profile. In case of formation
of several bearing profiles one above the other, the lengths of the bearing profiles as well as the distance
between the fixed points of two bearing profiles following each other must not exceed 2.80 m. The gap at
the joint of the cladding tiles and bearing profiles must be at least 6 mm. Corresponding gaps at the joints
must be allowed for in the event of site trimming. Joints of the bearing profiles may not be overlapped by
cladding tiles.
Installation of joint profile:
In order to fasten the joint profile, it is clamped into the vertical profile. At the same time, it rests on the
beads executed in the webs of the joint profile on the reverse side. As a rule, it is secured against falling off
through insertion of the tiles. At the same time, the tiles are pushed to the vertical profile by the joint profile
in order to avoid the generation of noise of the tiles in case of load from wind pressure. Attention must be
paid to the height locks of the system profiles when inserting the joint profile and to the fact that the joint
profile is inserted in such way that the required clamping effect of the tiles is achieved. In case of soffits,
we recommend to screw the joint profile onto the vertical profile in order to completely rule out a possible
horizontal shifting of the joint profile and of the inserted tiles.
PLANNING BASICS & INSTALLATION
39
EFFECTIVE SPANSMaximum effective spans of the TONALITY® cladding tiles as single-span girders under positive wind load for
the ADS System
Positive wind load [kN/m2] +0.50 +0.80 +1.00 +1.50 +2.00 +2.50 +3.00
Maximum effective span [m]
Tile 150* 1.20 1.20 1.20 1.20 1.10 0.98 0.89
Tile 175 1.17 0.96 0.83 0.68 0.59 0.52 0.48
Tile 200 1.20 1.15 1.00 0.82 0.71 0.63 0.58
Tile 225 1.20 1.02 0.88 0.72 0.63 0.56 0.51
Tile 250* 1.20 1.20 1.20 1.04 0.90 0.81 0.74
Tile 300* 1.20 1.20 1.20 0.99 0.88 0.77 0.70
* The tiles 150, 250 and 300 may only be used with the systems ADS and BAS
Maximum effective spans of the TONALITY® cladding tiles as single-span girders under negative wind load
(wind suction) for the ADS System
Negative wind load [kN/m2] –0.50 -0.80 -1.00 -1.50 -2.00 -2.50 -3.00
Maximum effective span [m]
Tile 150* 1.20 1.20 1.20 1.20 1.20 1.20 1.07
Tile 175 1.20 1.20 0.97 0.65 0.49 0.39 0.32
Tile 200 1.20 1.13 0.85 0.57 0.43 0.34 0.28
Tile 225 1.20 1.20 0.98 0.65 0.49 0.39 0.33
Tile 250* 1.20 1.20 1.20 1.20 1.20 0.96 0.80
Tile 300* 1.20 1.20 1.20 1.11 0.83 0.67 0.56
* The tiles 150, 250 and 300 may only be used with the system ADS
PLANNING BASICS & INSTALLATION
Ordering and planning instructions Determine the distance of the façade to the carcass of the building taking into account the thickness of the insulation and the unrestricted ventilation (see DIN 18516). The established distance is important for your order of the primary sub-construction.
Plan the module sectioning (tile lengths) in agreement with the architect/building owner methodically. In this context, it will be necessary to verify details, connections, etc., by presentation of drawings.
Perform the site measuring and determine the quantities of tiles, profiles, wall brackets, joining plates, etc.
Determine the profiles, wall brackets, connection components and the plugs admitted for this use by the construction supervising authority. Perform static calculations for loadbearing profiles and anchorings and if necessary, have these calculations reviewed.
Perform the sectioning of profiles according to length
Profile Tile height with max.length tile length of2.694 mm = 18 x 150 mm x 900 mm2.794 mm = 16 x 175 mm x 900 mm2.794 mm = 14 x 200 mm x 1.600 mm2.694 mm = 12 x 225 mm x 1.600 mm2.744 mm = 11 x 250 mm x 1.600 mm2.894 mm = 9 x 300 mm x 1.600 mm2.794 mm = 7 x 400 mm x 1.600 mm■
As a rule, the length of the T-profile must correspond to the length of the „TONALITY“- vertical profile in case of vertical sub-construction. The façade must be installed free of constraint forces through fixed and floating point connections.
Order the tiles indicating their dimensions for trimming to size. In case of special lengths of the profiles (only after consultation), the installer must draw up production plans.
In order to avoid interruptions of the installation due to breakage or clippings, it is recommended to add on approx. 5 % to the required amount (depending on the building project 5 –15%).
The clear and biding order is placed electronically using the respective order form, which will be submitted by our Sales Service.
40
ADAPTIVE SYSTEM (ADS)
Cladding tile tonality® 45
PLANNINGBASESANDPROCESSING
Adaptive System (ADS) Base Clinch Rail System (BAS)
PLANNING BASES AND PROCESSING
Base Clinch Rail System (BAS)
Zu
Zo
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
*
joint profile
L
6.
E
Baseclinch rail
profile
grid
hei
ght
grid
hei
ght
dim
ensi
on L
A
4
6.*
* Thermal linear expansion requir 6 mm between both 2 adjacent (see NTA National Technical Ap
26
Zu
Zo
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
Zo
Zu
* Thermal linear expansion least 6 mm between both (see NTA National Technic
L
Prgr
ZoZu
grid h
eig
ht
Classicverticalprofile
*
joint profile
grid h
eig
ht
dim
en
sion
L
A
6.
E
Zo
Zu
M
26
42
,5
Neoprene
Module
150
175
200
225
250
300
400
No. ofmodules
18
16
14
12
11
9
7
Size L
2694
2794
2794
2694
2744
2694
2794
Size A
45
45
52
45
52
102
102
Size B
75
100
100
150
150
150
200
Size C
75
75
100
75
100
150
200
Size E
24
24
42
24
42
42
92
Size M
12
12
30
12
30
30
80
Adaptive System (ADS)
Module
150
175
200
225
250
300
400
No. ofmodules
18
16
14
12
11
9
7
Size L
2694
2794
2794
2694
2744
2694
2794
Size A
56.5
56.5
63.5
56.5
63.5
113.5
113.5
Size B
75
100
100
150
150
150
200
Size C
75
75
100
75
100
150
200
Size E
12.5
12.5
30.5
12.5
30.5
30.5
80.5
Size M
12
12
30
12
30
30
80
Classic Profile System (CLS)
Module
150
175
200
225
250
300
400
No. ofmodules
18
16
14
12
11
9
7
Size L
2694
2794
2794
2694
2744
2694
2794
Size A
57
57
64
57
64
114
114
Size B
75
100
100
150
150
150
200
Size C
75
75
100
75
100
150
200
Size E
75
100
100
150
150
150
80
45Planning & Application 2009 Cladding tiles TONALITY®
Zo: Tile fastening at the topZu: Tile fastening at the bottom
Profile length = number of modules less 6 mm * For thermal expansion reasons, the joint dis-tance of the tiles and profiles must be at least 6mm (see Technical Approval).
TonalityWafu_GB_2009-2.qxp:Tonality_2009 04.08.2009 8:02 Uhr Seite 45
Zo: Tile fastening at the topZu: Tile fastening at the bottom
Profile length = number of modules less 6 mm
ADAPTIVE SYSTEM (ADS)Module +0.50 Size L Size A Size B Size C Size E Size M
150 18 2694 45 75 75 24 12
175 16 2794 45 100 75 24 12
200 14 2794 52 100 100 42 30
225 12 2694 45 150 75 24 12
250 11 2744 52 150 100 42 30
300 9 2694 102 150 150 42 30
400 7 2794 102 200 200 92 80
PLANNING BASICS & INSTALLATION
43
REFERENCES
The Data Centre, Toronto ON – WZMH & Urbacon
Fortinos, Vaughan ON – Turner Fleischer Architects
MaRS, Toronto ON – B+H Architects
44
Engineered Assemblies Inc.
1.866.591.7021info@engineeredassemblies.comEngineeredAssemblies.com
brilliant buildings