+ All Categories
Home > Documents > Tool N Existing - Knysna · All work to comply with National Building Regulations SANS 10400. No...

Tool N Existing - Knysna · All work to comply with National Building Regulations SANS 10400. No...

Date post: 01-Sep-2018
Category:
Upload: lyanh
View: 227 times
Download: 0 times
Share this document with a friend
2
GSPublisherVersion 0.0.100.100 4970 4302 203 195 2077 1740 160 4769 1746 FLAMINGO AVENUE FLAMINGO AVENUE SWAN STREET SWAN STREET SEDGEWARBLER STREET SEDGEWARBLER STREET FLAMINGO STREET FLAMINGO STREET SWAN STREET SWAN STREET μ 0 0,02 0,04 0,01 km Scale: 1:500 Date: 2016/06/02 Time: 15:17 (GMT +2) Coordinate System: GCS WGS 1984 Datum: WGS 1984 Please note that due to the number of layers in the table of content, some items may not appear in the legend This map was created using ArcMap 10.3 1 cm = Approx. 5 meters Previous Erf 195 Sedgefield DISCLAIMER: Knysna Municipality and the author of this map accepts no liability for any action, breach or claim resulting from the use of the GIS information provided by the author of this map or for the consequences of any actions taken on the basis of the information provided on this map. It is thus recorded that it remains the responsibility of the user of this information to ensure that the information is not used contrary to the purpose for which it was intended and to exercise reasonable care when using same. SED195_Holloway_rev2.pln SED195_Holloway_rev2.pln 0 1 2 3 4 5 Floor plan, site, fence details Additions to existing house on Erf 195, Sedgefield, for owner: Mr & Mrs Holloway of 2 1 A1 SCALE REVISION PAPER SIZE DRAWING: PROJECT: 0 Issued for approval REVISION DATE REVISION DETAILS 5cm on original A1 drawing Henry Greyling | Ph 071 382 3566 |[email protected] | www.hgdesign.co.za Architectural Design & DraughƟng | Project Management Registered SACAP D2253 DRAWING TITLE: 17/06/2016 GENERAL NOTES : All work to comply with National Building Regulations SANS 10400. No measurements to be scaled. All dimensions to be verified on site. Read drawings in conjunction with Eng. detail. ALL REINFORCED CONCRETE WORK TO BE ACCORDING TO STRUCTURAL ENGINEER'S DESIGN AND DETAIL. The building owner is responsible for ensuring that their project is SANS compliant and signed off by a qualified Engineer. STAIRS AND RAILING: A NON COMPLIANT BALUSTRADE IS A SAFETY RISK. ENSURE THE BALUSTRADE SYSTEM IS INSTALLED CORRECTLY: SANS 10400 Part B, Part D and Part M, SANS 10160-2:2011. Steps and risers as shown. Risers as indicated on drawing and run as indicated on drawing, minimum balustrade height 1000mm. Opening between rails and / or droppers not to exceed 100mm. Any balustrade or wall provided to protect a change in level shall comply with the requirements of SANS 10400-B. FIRE PROTECTION: SANS 10400 Part T: The requirements of the Act will be deemed to have been satisfied if the design, construction and equipment of buildings complies with SANS 10400 Part T and satisfies the local authority. STORM WATER: SANS 10400 Part R: The owner of any site shall provide suitable means for the control and disposal of accumulated stormwater which may run off from any earthworks, building or paving. CONTRACTOR MUST ENSURE THAT STORM WATER DOES NOT DAMAGE EXISTING BUILDING WORK OR NEIGHBOURING PROPERTIES DURING CONSTRUCTION AND THAT STORMWATER DRAINAGE IS SUFFICIENT. RAINWATER DISPOSAL: Provide 1m paving around building with fall away from structure where practical. GUTTERS & DOWN PIPES TO BE INSTALLED. SEWERAGE: All sanitary appliances to be supplied with antisuction traps and/or ventilated according to nbr requirements. -ie's at all bends, connections and changes of gradient with marked covers on ground level. Sufficient access panels to be installed in all shafts over ie's. -all sanitary pipes to be accessible. All reinforced concrete work to be according to structural engineer's design and detail. SITE PREPARATION: Remove top-soil and organic material within interior footprint of building and paving. Above material not to be used as backfill. Keep site dry. FOUNDATION: SANS 10400 Part H: All foundations concrete strip foundations unless specified. Concrete minimum 15MPa after 28 days. FILLING: SANS 10400 Part J (JJ2.3): Backfill to be compacted in layers not more than 150mm layers to specs. SURFACE BEDS: Minimum 100mm thick 15MPa on DPC. Expansion joints to be provided 20m² max. WATERPROOFING: SANS 10400 Part J(JJ3) and Sec. K(KK15): Provide 250 micron USB DPC underneath all surface beds and 375 micron Black DPC in walls with min. 100mm overlap at joints. Provide "Brickgrip" DPC underneath all window sills. All joints according to specifications. BRICKWORK: SANS 10400 Part K: Brickwork in stretching bond with minimum joint thickness of 10mm. Interior walls minimum 110mm thick. Brick as indicated. Stock bricks to be kept clean of mortar. Provide brickforce in each layer for foundation walls, (5 layers minimum), each layer above windows and doors and at 4 course intervals: use alternate layer of 75mm brickforce and butterfly tie-wires for all other 280mm brickwork. Use 75mm brickforce in each course every 4 layers for 110mm and 220mm brick walls. PLASTER WORK: One layer plaster minimum 12mm thick. ROOF: Construction & Material to comply with SANS 10400 Part L and SANS 1900:2009 GLAZING: SANS 10400 Part N, SABS 0137-200, SABS 1263: Clear Glass unless specified. Mark all sliding doors visible. SAFETY GLASS IN ALL DOORS AND WINDOWS LOWER THAN 300mm FROM GROUND LEVEL AND LARGER THAN 1 m². GEYSERS: SABS 0254 With drip-tray. SPACE HEATING & CHIMNEYS: To comply with SANS 10400: Part V. ALL WORK TO BE PERFORMED TO MUNICIPAL & NATIONAL BUILDING REGULATIONS SANS 10400 COPYRIGHT NOTICE Copyright © 2016 SH Greyling. Copyright subsists in this drawing. The person or entity whose name appears in the title block of this drawing, is hereby granted a non-exclusive license to use, display, print and / or reproduce this drawing to the extent necessary to carry out and complete the project described in the title block of this drawing. This license in respect of the copyright is expressly limited as aforesaid and the person and/or entity referred to above shall not be entitled to grant sub-licenses in respect of the copyright in this drawing to any other entity. This license confers no ownership rights in the copyright vesting in the drawing and this drawing and the copyright subsisting therein will, at all times, remain the property of SH Greyling. Any unauthorized reproduction, publication, transmission, adaptation and/or inclusion of this drawing in a cinematograph film or television broadcast is an act of copyright infringement which will render the doer of the act liable for civil law copyright infringement and may in certain circumstances render the doer liable to criminal prosecution. Requests and enquiries concerning this drawing and the rights subsisting therein should be addressed to the copyright owner. ACTS OF PARLIAMENT All Contractors shall ensure that, before any work is put in hand, they comply with all the necessary Acts of Parliament of the Republic of South Africa. AREAS : Previously approved areas 165.82m² House, garage & wendy (x2) 165.82m² 1.8m vibracrete fence 9m 1.5m picket fence incl gate 57.6m Total Footprint 165.82m² Erf 853.00m² Coverage 19.44% as shown SHEET: DRAWN BY HG 1 Amended rafter specification 12/07/2016 2 Amended fence and carport 04/08/2016 N 5000 6 262 5 577 3 570 3000 4 059 5 000 4 500 7 000 7 491 39.360m 3m building line 3m building line 5m building line 10.500m 11.330m 5m building line 24.600m 8.720m 13.060m Erf 194 Erf 187 Erf 195 8 Flamingo Avenue, Sedgefield Flamingo Avenue Swan Street Sedgewarbler Way 5 m building line Existing 1.8m Vibracrete wall Extend existing 1.2m high Vibracrete wall to 1.8m Extend existing 1.2m high Vibracrete wall to 1.8m 1.5m high timber picket fence 1.5m high timber picket fence 1.5m high timber picket fence 1.5m high sliding gate 76 20 1 500 1500mm AVERAGE ABOVE NATURAL GROUND LEVEL MIN. 75mm DIA CCA SA PINE POST @ 3000mm C/C 22x76x1500mm CCA SA PINE PICKET NATURAL GROUND LEVEL W DR UP 1 2 3 4 5 6 7 8 9 10 11 12 13 3 600 1 180 355 3 690 355 355 132 173 355 2 888 355 2 888 355 5 580 6 840 A A Remove window, fit fire proof door Fire proof wall Amended garage 38.09m² (screed) roof line Existing house Tool storage 400 400 MIN. 75mm DIA CCA SA PINE POST @ 3000mm C/C 38x114mm CCA SA PINE BEAM 38x114mm CCA SA PINE BEAM RC FOOTING 22x76x1500mm CCA SA PINE PICKET site boundary FENCE NOT TO ENCROACH OVER BOUNDARY 5 CSG 1:2000 4 Site plan 1:100 2 Typical fence elevation 1:20 1 Floor Plan 1:50 3 Typical fence section 1:20
Transcript

GSPublisherVersion 0.0.100.100

4970

4302

203

195

2077

1740

160

4769

1746

F L A M I N G O A V E N U E

F L A M I N G O A V E N U E

SWA N S T R E E T

S WA N S T R E E T

S E D G E WA R B L E R S

T R E E T

S E D G E WA R B L E R S

T R E E T

F L A M I N G O S T R E E T

F L A M I N G O S T R E E T

S WA N S

T R E E T

S WA N S

T R E E T

µ0 0,02 0,040,01 km

Scale: 1:500

Date: 2016/06/02Time: 15:17 (GMT +2)

Coordinate System: GCS WGS 1984Datum: WGS 1984

Please note that due to the number of layers in the tableof content, some items may not appear in the legend

This map was created usingArcMap 10.3

1 cm = Approx. 5 meters

Previous Erf 195 Sedgefield

DISCLAIMER:Knysna Municipality and the author of this map accepts no liability for any action,breach or claim resulting from the use of the GIS information provided by the author ofthis map or for the consequences of any actions taken on the basis of the informationprovided on this map.It is thus recorded that it remains the responsibility of the user of this information toensure that the information is not used contrary to the purpose for which it was intendedand to exercise reasonable care when using same.

SED195_Holloway_rev2.pln SED195_Holloway_rev2.pln

0 1 2 3 4 5

Floor plan, site, fence details

Additions to existing house on Erf 195, Sedgefield, for owner: Mr & Mrs Holloway

of 21

A1SCALE REVISIONPAPER SIZEDRAWING:

PROJECT:

0 Issued for approvalREVISION DATE REVISION DETAILS

5cm on original A1 drawing

Henry Greyling | Ph 071 382 3566 |[email protected] | www.hgdesign.co.za

Architectural Design & Draugh ng | Project ManagementRegistered SACAP D2253

DRAWING TITLE:

17/06/2016

GENERAL NOTES:All work to comply with National Building Regulations SANS 10400. No measurements to be scaled. Alldimensions to be verified on site. Read drawings in conjunction with Eng. detail.ALL REINFORCED CONCRETE WORK TO BE ACCORDING TO STRUCTURAL ENGINEER'S DESIGNAND DETAIL. The building owner is responsible for ensuring that their project is SANS compliantand signed off by a qualified Engineer.

STAIRS AND RAILING: A NON COMPLIANT BALUSTRADE IS A SAFETY RISK. ENSURE THEBALUSTRADE SYSTEM IS INSTALLED CORRECTLY: SANS 10400 Part B, Part D and Part M, SANS10160-2:2011. Steps and risers as shown. Risers as indicated on drawing and run as indicated ondrawing, minimum balustrade height 1000mm. Opening between rails and / or droppers not to exceed100mm. Any balustrade or wall provided to protect a change in level shall comply with the requirements ofSANS 10400-B.

FIRE PROTECTION: SANS 10400 Part T:The requirements of the Act will be deemed to have been satisfied if the design, construction andequipment of buildings complies with SANS 10400 Part T and satisfies the local authority.

STORM WATER: SANS 10400 Part R:The owner of any site shall provide suitable means for the control and disposal of accumulated stormwaterwhich may run off from any earthworks, building or paving. CONTRACTOR MUST ENSURE THATSTORM WATER DOES NOT DAMAGE EXISTING BUILDING WORK OR NEIGHBOURINGPROPERTIES DURING CONSTRUCTION AND THAT STORMWATER DRAINAGE IS SUFFICIENT.

RAINWATER DISPOSAL:Provide 1m paving around building with fall away from structure where practical. GUTTERS & DOWNPIPES TO BE INSTALLED.

SEWERAGE: All sanitary appliances to be supplied with antisuction traps and/or ventilated according tonbr requirements. -ie's at all bends, connections and changes of gradient with marked covers on groundlevel. Sufficient access panels to be installed in all shafts over ie's. -all sanitary pipes to be accessible. Allreinforced concrete work to be according to structural engineer's design and detail.

SITE PREPARATION:Remove top-soil and organic material within interior footprint of building and paving. Above material not tobe used as backfill. Keep site dry.

FOUNDATION: SANS 10400 Part H:All foundations concrete strip foundations unless specified. Concrete minimum 15MPa after 28 days.

FILLING: SANS 10400 Part J (JJ2.3):Backfill to be compacted in layers not more than 150mm layers to specs.

SURFACE BEDS:Minimum 100mm thick 15MPa on DPC. Expansion joints to be provided 20m² max.

WATERPROOFING: SANS 10400 Part J(JJ3) and Sec. K(KK15): Provide 250 micron USB DPCunderneath all surface beds and 375 micron Black DPC in walls with min. 100mm overlap at joints.Provide "Brickgrip" DPC underneath all window sills. All joints according to specifications.

BRICKWORK: SANS 10400 Part K: Brickwork in stretching bond with minimum joint thickness of 10mm.Interior walls minimum 110mm thick. Brick as indicated. Stock bricks to be kept clean of mortar. Providebrickforce in each layer for foundation walls, (5 layers minimum), each layer above windows and doors andat 4 course intervals: use alternate layer of 75mm brickforce and butterfly tie-wires for all other 280mmbrickwork. Use 75mm brickforce in each course every 4 layers for 110mm and 220mm brick walls.

PLASTER WORK:One layer plaster minimum 12mm thick.

ROOF:Construction & Material to comply with SANS 10400 Part L and SANS 1900:2009

GLAZING:SANS 10400 Part N, SABS 0137-200, SABS 1263: Clear Glass unless specified. Mark all sliding doorsvisible. SAFETY GLASS IN ALL DOORS AND WINDOWS LOWER THAN 300mm FROM GROUNDLEVEL AND LARGER THAN 1 m².

GEYSERS: SABS 0254With drip-tray.

SPACE HEATING & CHIMNEYS:To comply with SANS 10400: Part V.

ALL WORK TO BE PERFORMED TO MUNICIPAL & NATIONAL BUILDING REGULATIONS SANS 10400

COPYRIGHT NOTICECopyright © 2016 SH Greyling. Copyright subsists in this drawing. The person or entity whose name appears in the title blockof this drawing, is hereby granted a non-exclusive license to use, display, print and / or reproduce this drawing to the extentnecessary to carry out and complete the project described in the title block of this drawing.This license in respect of the copyright is expressly limited as aforesaid and the person and/or entity referred to above shallnot be entitled to grant sub-licenses in respect of the copyright in this drawing to any other entity. This license confers no ownership rights in the copyright vesting in the drawing and this drawing and the copyright subsistingtherein will, at all times, remain the property of SH Greyling.Any unauthorized reproduction, publication, transmission, adaptation and/or inclusion of this drawing in a cinematograph filmor television broadcast is an act of copyright infringement which will render the doer of the act liable for civil law copyrightinfringement and may in certain circumstances render the doer liable to criminal prosecution. Requests and enquiriesconcerning this drawing and the rights subsisting therein should be addressed to the copyright owner.

ACTS OF PARLIAMENTAll Contractors shall ensure that, before any work is put in hand, they comply with all the necessary Acts of Parliament of theRepublic of South Africa.

AREAS:

Previously approved areas 165.82m²House, garage & wendy (x2) 165.82m²

1.8m vibracrete fence 9m1.5m picket fence incl gate 57.6m

Total Footprint 165.82m²Erf 853.00m²

Coverage 19.44%

asshown

SHEET:

DRAWN BY HG

1 Amended rafter specification12/07/20162 Amended fence and carport04/08/2016

N

5000 6

262

5 577

3 57

0 3000

4 059

5 000

4 500

7 00

07

491

39.360m

3m building line

3m b

uild

ing

line

5m building line

10.5

00m

11.330m5m building line

24.600m

8.720

m

13.0

60m

Erf 194

Erf 187

Erf 1958 FlamingoAvenue,Sedgefield

Flamingo Avenue

Swan Street

Sedg

ewar

bler

Way

5m building line

Existing 1.8m Vibracrete wall

Extend existing 1.2m high Vibracrete wall to 1.8m

Extend existing 1.2m highVibracrete wall to 1.8m

1.5m high timberpicket fence

1.5m high timberpicket fence

1.5m high timberpicket fence

1.5m high sliding gate

76 20

1 50

01500mm AVERAGE ABOVENATURAL GROUND LEVELMIN. 75mm DIA CCA

SA PINE POST @3000mm C/C

22x76x1500mmCCA SA PINE

PICKET

NATURAL GROUND LEVEL

WD

R

UP

1234

5

6

7

8

9

10

11

12

13

3 600

1 180 355 3 690 355

355

132

173

355

2 88

835

52

888

355

5 580

6 84

0

A A

Removewindow, fit fireproof door

Fire proof wall

Amendedgarage38.09m²(screed)

roof

line

Existinghouse

Toolstorage

400

400

MIN. 75mm DIA CCASA PINE POST @3000mm C/C

38x114mm CCA SAPINE BEAM

38x114mm CCA SAPINE BEAM

RC FOOTING

22x76x1500mmCCA SA PINE

PICKET

site

bou

ndar

y

FENCE NOT TOENCROACHOVERBOUNDARY

5 CSG 1:2000

4 Site plan 1:100

2 Typical fence elevation 1:20

1 Floor Plan 1:50

3 Typical fence section 1:20

GSPublisherVersion 0.0.100.100

4970

4302

203

195

2077

1740

160

4769

1746

F L A M I N G O A V E N U E

F L A M I N G O A V E N U E

SWA N S T R E E T

S WA N S T R E E T

S E D G E WA R B L E R S

T R E E T

S E D G E WA R B L E R S

T R E E T

F L A M I N G O S T R E E T

F L A M I N G O S T R E E T

S WA N S

T R E E T

S WA N S

T R E E T

µ0 0,02 0,040,01 km

Scale: 1:500

Date: 2016/06/02Time: 15:17 (GMT +2)

Coordinate System: GCS WGS 1984Datum: WGS 1984

Please note that due to the number of layers in the tableof content, some items may not appear in the legend

This map was created usingArcMap 10.3

1 cm = Approx. 5 meters

Previous Erf 195 Sedgefield

DISCLAIMER:Knysna Municipality and the author of this map accepts no liability for any action,breach or claim resulting from the use of the GIS information provided by the author ofthis map or for the consequences of any actions taken on the basis of the informationprovided on this map.It is thus recorded that it remains the responsibility of the user of this information toensure that the information is not used contrary to the purpose for which it was intendedand to exercise reasonable care when using same.

SED195_Holloway_rev2.pln SED195_Holloway_rev2.pln

0 1 2 3 4 5

Elevations & section

Additions to existing house on Erf 195, Sedgefield, for owner: Mr & Mrs Holloway

of 22

A1SCALE REVISIONPAPER SIZEDRAWING:

PROJECT:

0 Issued for approvalREVISION DATE REVISION DETAILS

5cm on original A1 drawing

Henry Greyling | Ph 071 382 3566 |[email protected] | www.hgdesign.co.za

Architectural Design & Draugh ng | Project ManagementRegistered SACAP D2253

DRAWING TITLE:

17/06/2016

GENERAL NOTES:All work to comply with National Building Regulations SANS 10400. No measurements to be scaled. Alldimensions to be verified on site. Read drawings in conjunction with Eng. detail.ALL REINFORCED CONCRETE WORK TO BE ACCORDING TO STRUCTURAL ENGINEER'S DESIGNAND DETAIL. The building owner is responsible for ensuring that their project is SANS compliantand signed off by a qualified Engineer.

STAIRS AND RAILING: A NON COMPLIANT BALUSTRADE IS A SAFETY RISK. ENSURE THEBALUSTRADE SYSTEM IS INSTALLED CORRECTLY: SANS 10400 Part B, Part D and Part M, SANS10160-2:2011. Steps and risers as shown. Risers as indicated on drawing and run as indicated ondrawing, minimum balustrade height 1000mm. Opening between rails and / or droppers not to exceed100mm. Any balustrade or wall provided to protect a change in level shall comply with the requirements ofSANS 10400-B.

FIRE PROTECTION: SANS 10400 Part T:The requirements of the Act will be deemed to have been satisfied if the design, construction andequipment of buildings complies with SANS 10400 Part T and satisfies the local authority.

STORM WATER: SANS 10400 Part R:The owner of any site shall provide suitable means for the control and disposal of accumulated stormwaterwhich may run off from any earthworks, building or paving. CONTRACTOR MUST ENSURE THATSTORM WATER DOES NOT DAMAGE EXISTING BUILDING WORK OR NEIGHBOURINGPROPERTIES DURING CONSTRUCTION AND THAT STORMWATER DRAINAGE IS SUFFICIENT.

RAINWATER DISPOSAL:Provide 1m paving around building with fall away from structure where practical. GUTTERS & DOWNPIPES TO BE INSTALLED.

SEWERAGE: All sanitary appliances to be supplied with antisuction traps and/or ventilated according tonbr requirements. -ie's at all bends, connections and changes of gradient with marked covers on groundlevel. Sufficient access panels to be installed in all shafts over ie's. -all sanitary pipes to be accessible. Allreinforced concrete work to be according to structural engineer's design and detail.

SITE PREPARATION:Remove top-soil and organic material within interior footprint of building and paving. Above material not tobe used as backfill. Keep site dry.

FOUNDATION: SANS 10400 Part H:All foundations concrete strip foundations unless specified. Concrete minimum 15MPa after 28 days.

FILLING: SANS 10400 Part J (JJ2.3):Backfill to be compacted in layers not more than 150mm layers to specs.

SURFACE BEDS:Minimum 100mm thick 15MPa on DPC. Expansion joints to be provided 20m² max.

WATERPROOFING: SANS 10400 Part J(JJ3) and Sec. K(KK15): Provide 250 micron USB DPCunderneath all surface beds and 375 micron Black DPC in walls with min. 100mm overlap at joints.Provide "Brickgrip" DPC underneath all window sills. All joints according to specifications.

BRICKWORK: SANS 10400 Part K: Brickwork in stretching bond with minimum joint thickness of 10mm.Interior walls minimum 110mm thick. Brick as indicated. Stock bricks to be kept clean of mortar. Providebrickforce in each layer for foundation walls, (5 layers minimum), each layer above windows and doors andat 4 course intervals: use alternate layer of 75mm brickforce and butterfly tie-wires for all other 280mmbrickwork. Use 75mm brickforce in each course every 4 layers for 110mm and 220mm brick walls.

PLASTER WORK:One layer plaster minimum 12mm thick.

ROOF:Construction & Material to comply with SANS 10400 Part L and SANS 1900:2009

GLAZING:SANS 10400 Part N, SABS 0137-200, SABS 1263: Clear Glass unless specified. Mark all sliding doorsvisible. SAFETY GLASS IN ALL DOORS AND WINDOWS LOWER THAN 300mm FROM GROUNDLEVEL AND LARGER THAN 1 m².

GEYSERS: SABS 0254With drip-tray.

SPACE HEATING & CHIMNEYS:To comply with SANS 10400: Part V.

ALL WORK TO BE PERFORMED TO MUNICIPAL & NATIONAL BUILDING REGULATIONS SANS 10400

COPYRIGHT NOTICECopyright © 2016 SH Greyling. Copyright subsists in this drawing. The person or entity whose name appears in the title blockof this drawing, is hereby granted a non-exclusive license to use, display, print and / or reproduce this drawing to the extentnecessary to carry out and complete the project described in the title block of this drawing.This license in respect of the copyright is expressly limited as aforesaid and the person and/or entity referred to above shallnot be entitled to grant sub-licenses in respect of the copyright in this drawing to any other entity. This license confers no ownership rights in the copyright vesting in the drawing and this drawing and the copyright subsistingtherein will, at all times, remain the property of SH Greyling.Any unauthorized reproduction, publication, transmission, adaptation and/or inclusion of this drawing in a cinematograph filmor television broadcast is an act of copyright infringement which will render the doer of the act liable for civil law copyrightinfringement and may in certain circumstances render the doer liable to criminal prosecution. Requests and enquiriesconcerning this drawing and the rights subsisting therein should be addressed to the copyright owner.

ACTS OF PARLIAMENTAll Contractors shall ensure that, before any work is put in hand, they comply with all the necessary Acts of Parliament of theRepublic of South Africa.

AREAS:

Previously approved areas 165.82m²House, garage & wendy (x2) 165.82m²

1.8m vibracrete fence 9m1.5m picket fence incl gate 57.6m

Total Footprint 165.82m²Erf 853.00m²

Coverage 19.44%

asshown

SHEET:

DRAWN BY HG

1 Amended rafter specification12/07/20162 Amended fence and carport04/08/2016

corrugated polycarbonate sheets

facebrick

IBR metal sheets

tiles

weatherboard

corrugated metal sheets

Face brick columns

Handiplank

facebrick

IBR metal sheets

tiles

facebrick

facebrick

whb

wc

sh

bwc

whbs

re

ieieieieieExisting septic tank Existing sewer Existing sewer

Face brick columnsHandiplank

facebrick

IBR metal sheets

tiles

weatherboard

tiles

corrugatedpolycarbonate sheets

330

2 74

8

2 29

1

1 357 4 050

4

6

7

5

15

1

2

3

7

13

14 16

17

8

10

10

Existinghouse

Approvedcarport

amended toproposedgarage

NGL

FFL

FFL

5° 9

SECTION LEGEND: FFL - FINAL FLOOR LEVEL, NGL - NATURAL GROUND LEVEL

THE NEW CONSTRUCTION TO MATCH EXISTING HOUSE AS MUCH AS POSSIBLE

1. Existing foundations and brick rising walls.2. Existing concrete slab.3. Existing walls: 230 brick walls, facebrick exterior skin, plaster & paint interior.4. Existing roof as per approved plan:119/1991/1955. New garage doors as chosen by owner.6. New external door as chosen by owner.7. As-built foundations.8. Ensure timber beams are anchored into brickwork as per NBR.9. 50x228mm Grade 6 CCA SA Pine beam.10. 38x114mm CCA SA Pine timber frame wall, studs @ 600mm c/c. Clad with Nutec handiplankon exterior and 9mm Rhinoboard on interior. Paint to owner's specification.13. New RC surfce bed on 250micron DPC on compacted hardcore. Screed finish.14. Extend existing facebrick columns to correct height. Finish to match existing.15: Roof: Pitch 5°. IBR metal sheeting on 50x76mm purlins @ 950 c/c max on 50x152mm Grade 6 CCA SA Pine rafters @ 1050mm c/c max. Designed by specialist.16: Provide lintols above openings: 2 ply 50x152 CCA SA Pine beam.17. PVC gutter and downpipe on white facia and barge boards to match existing house.

North East Elevation 1:50

South West Elevation 1:50

South East Elevation 1:50 A - A Section 1:50


Recommended