+ All Categories
Home > Documents > Top View Front Panel showing Programming Options drawings/P… · Analog Interface Connector Ground...

Top View Front Panel showing Programming Options drawings/P… · Analog Interface Connector Ground...

Date post: 02-Oct-2018
Category:
Upload: dinhhuong
View: 218 times
Download: 0 times
Share this document with a friend
3
Analog Interface Connector Ground Stud (M5) HV Output Positive Polarity 0V CONNECT WITHOUT VOLTAGE HighVoltage Warning Label PHV Series Half Rack Model Typical Front and Rear Panel Layouts Front Panel showing Programming Options Rear Panel Top View Negative Polarity Reversible Polarity LINE/FUSE ANALOG PROGRAMMING ! ! ! WARNUNG Hochspannung! Berührung kann tödlichen Stromschlag verursachen! Nur spannungslos stecken! Anleitung beachten! ! WARNING High voltage. Contact may cause death. Connect only Refer to operating manual. when output is not live. ! i Standard Front Panel Positive Polarity Negative Polarity Reversible With Analog Programming With Digital Programming Analog & Digital Programming DC POWER SUPPLY TEMP POWER OUTPUT POLARITY POS OFF ON VOLTAGE SET VALUES V-LIMIT CURRENT 0...3.5kV 0...40mA PHV3.5P40 CV CC kV mA ! POWER OUTPUT POLARITY NEG OFF ON ! POWER OUTPUT POLARITY NEG POS OFF ON ! LOCAL REMOTE ANALOG PROGRAMMING LOCAL BUSY DIGITAL REMOTE PROGRAMMING LOCAL BUSY DIGITAL REMOTE PROGRAMMING ANALOG
Transcript

Analog InterfaceConnector

GroundStud (M5)

HV Output

Positive Polarity

0V

CONNECT WITHOUTVOLTAGE

HighVoltage Warning Label

PHV Series Half Rack ModelTypical Front and Rear Panel Layouts

Front Panel showing Programming Options

Rear Panel

Top View

Negative Polarity

Reversible Polarity

LINE/FUSE

ANALOGPROGRAMMING

! !

!

WARNUNG

Hochspannung!Berührung kanntödlichenStromschlagverursachen!Nur spannungslosstecken!Anleitung beachten!

!WARNING

High voltage.

Contact maycause death.

Connect only

Refer to operating manual.

when outputis not live.

!

i

Standard Front Panel

Positive Polarity

Negative Polarity

Reversible

With Analog Programming

With Digital Programming

Analog & Digital Programming

DC POWER SUPPLY

TEMP

POWER OUTPUT POLARITY

POS

OFF

ON

VOLTAGESET VALUES

V-LIMIT

CURRENT

0...3.5kV 0...40mAPHV3.5P40

CV CC

kV mA

!

POWER OUTPUT POLARITY

NEGOFF

ON!

POWER OUTPUT POLARITY

NEG

POS

OFF

ON!

LOCAL

REMOTE ANALOG

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

ANALOG

4,5 SKA-Bolzen M3x35 II KU

Befestigung aufErd-Seite = ST-SchraubenHV-Seite = KU-Schrauben

L2BV1080PM50/39

M1BV10982U100

CONNECT WITHOUTVOLTAGE! !

0V

Positive Polarity

Negative Polarity

Reversible Polarity

!ANALOG

PROGRAMMING

LINE/FUSE

PHV Series Full Rack ModelTypical Front and Rear Panel Layouts

Front Panel showing Programming Options

Rear Panel

Top View

DC POWER SUPPLY

TEMP

POWER OUTPUT POLARITY

POS

OFF

ON

VOLTAGESET VALUES

V-LIMIT

CURRENT

0...6.5kV 0...100mAPHV6.5P100

CV CC

kV mA

!

!

!

Positive Polarity

Negative Polarity

Reversible

With Analog Programming

With Digital Programming

Analog & Digital Programming

POWER OUTPUT POLARITY

NEGOFF

ON

POWER OUTPUT POLARITY

NEG

POS

OFF

ON

LOCAL

REMOTE ANALOG

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

ANALOG

Analog InterfaceConnector

HV Output

HV

0V

WARNUNG

Hochspannung!Berührung kanntödlichenStromschlagverursachen!Nur spannungslosstecken!Anleitung beachten!

!WARNING

High voltage.

Contact maycause death.

Connect only

Refer to operating manual.

when outputis not live.

!

i

CONNECT WITHOUT VOLTAGE

ANALOGPROGRAMMING

T2AH

AC INPUT

!

!

!

PHV Series Full Rack 6U HighTypical Front and Rear Panel Layouts

DC POWER SUPPLY

TEMP

POWER OUTPUT POLARITY

POS

OFF

ON

VOLTAGESET VALUES

V-LIMIT

CURRENT

0...12.5kV 0...400mAPHV12.5P400

CV CC

kV mA

!

!

!

Positive Polarity

Negative Polarity

Reversible

With Analog Programming

With Digital Programming

Analog & Digital Programming

POWER OUTPUT POLARITY

NEGOFF

ON

POWER OUTPUT POLARITY

NEG

POS

OFF

ON

LOCAL

REMOTE ANALOG

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

LOCAL

BUSY

DIGITAL

REMOTE

PROGRAMMING

ANALOG

WARNUNG

HoherAbleitstrom!Kann zu tödlichemStromschlag führen!Nicht ohne festangeschlossenenSchulzleiterbetreiben!Anleitung beachten!

!WARNING

HIGH LEAKAGECURRENTMay cause lethalelectric shock.

Earth connection

Refer to operating manual.

essential beforeconnecting supply.

!

i


Recommended