+ All Categories
Home > Documents > TR19120435-E-000 USB C HUB FCC SDOC Report

TR19120435-E-000 USB C HUB FCC SDOC Report

Date post: 11-Jan-2022
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
17
Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 1 of 17 Prepared for : Aukey Technology Co.,Ltd Address : Room 102, Building P09, South China City Electronic trading center, Longgang District,Shenzhen Prepared by : Guangdong KeywayTesting Technology Co., Ltd. Address : No.7 of Zhangmutou District, Guanzhang Road, Zhangmutou town, Dongguan Guangdong China. Tel: 86-769-87182258 Fax: 86-769-87181058 Report No. : TR19100442-E-000 Date of Test : Dec. 27, 2019~ Jan. 07, 2020 Date of Report : Jan. 08, 2020 FCC TEST REPORT for Aukey Technology Co.,Ltd USB C HUB Model Number:CB-C72, CB-C81, CB-C82, CB-C83, CB-C84, CB-C85, CB-C86, CB-C87, CB-C88, CB-C89, CB-C90, CB-C91, CB-C92, CB-C93, CB-C94, CB-C95
Transcript
Page 1: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 1 of 17

Prepared for : Aukey Technology Co.,LtdAddress : Room 102, Building P09, South China City Electronic

trading center, Longgang District,Shenzhen

Prepared by : Guangdong KeywayTesting Technology Co., Ltd.Address : No.7 of Zhangmutou District, Guanzhang Road, Zhangmutou

town, Dongguan Guangdong China.

Tel: 86-769-87182258Fax: 86-769-87181058

Report No. : TR19100442-E-000Date of Test : Dec. 27, 2019~ Jan. 07, 2020Date of Report : Jan. 08, 2020

FCC TEST REPORT

for

Aukey Technology Co.,Ltd

USB C HUB

Model Number:CB-C72, CB-C81, CB-C82, CB-C83, CB-C84,CB-C85, CB-C86, CB-C87, CB-C88, CB-C89, CB-C90, CB-C91,

CB-C92, CB-C93, CB-C94, CB-C95

Page 2: TR19120435-E-000 USB C HUB FCC SDOC Report
Page 3: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 3 of 17

TABLE OF CONTENTS

Test Report Declaration Page1. GENERAL PRODUCT INFORMATION..........................................................................................4

1.1. Product Function......................................................................................................................... 41.2. Description of Device (EUT)...................................................................................................... 41.3. Difference between Model Numbers........................................................................................41.4. Independent Operation Modes..................................................................................................41.5. Test Supporting System.............................................................................................................4

2. TEST SITES.........................................................................................................................................52.1. Test Facilities............................................................................................................................... 52.2. Test Summary..............................................................................................................................62.3. List of Test and Measurement Instruments.............................................................................7

3. TEST SET-UP AND OPERATION MODES................................................................................... 83.1. Principle of Configuration Selection......................................................................................... 83.2. Block Diagram of Test Set-up................................................................................................... 83.3. Test Operation Mode and Test Software................................................................................ 83.4. Special Accessories and Auxiliary Equipment........................................................................83.5. Countermeasures to Achieve EMC Compliance....................................................................8

4. TEST RESULTS..................................................................................................................................94.1. Conducted Emission at the Mains Terminals Test................................................................ 94.2. Radiated Emission Test (below 1 GHz).................................................................................104.3. Radiated Emission Test (above 1 GHz)................................................................................ 13

5. PHOTOGRAPHS OF TEST SET-UP.............................................................................................146. PHOTOGRAPHS OF THE EUT..................................................................................................... 15

Page 4: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 4 of 17

1. GENERAL PRODUCT INFORMATION

1.1.Product Function

Refer to Technical Construction Form and User Manual.

1.2.Description of Device (EUT)

Description : USB C HUB

M/N :CB-C72, CB-C81, CB-C82, CB-C83, CB-C84, CB-C85, CB-C86,CB-C87, CB-C88, CB-C89, CB-C90, CB-C91, CB-C92, CB-C93,CB-C94, CB-C95

Power Input : DC 5V fromPC

Output : DC 5VOperationfrequency

: <108MHz

Remark: CB-C72 was selected as the test model and its data have been recorded inthis report.

1.3.Difference between Model Numbers

Note:All models are the same except the product name

1.4.Independent Operation Modes

The basic operation mode is:

Mode Description

Mode 1 Data transmission

1.5.Test Supporting System

1.5.1 PCManufacturer : DELLModel Number : DCNE1FPower Cord : Unshielded, Detachable, 1.5mS/N : 13XHTD2Y

1.5.2 TVTVManufacturer : SONYModel Number : KDL-26X550Equip No. : 1020345

Page 5: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 5 of 17

2. TEST SITES

2.1.Test Facilities

Lab Qualifications : 944 Shielded Room built by ETS-Lindgren, USADate of completion: March 28, 2011

966 Chamber built by ETS-Lindgren, USADate of completion: March 28, 2011

Certificated by TUV Rheinland, Germany.Registration No.: UA 50207153Date of registration: July 13, 2011

Certificated by UL, USARegistration No.: 100567237Date of registration: September 5, 2012

Certificated by IntertekRegistration No.: 2016-RTL-L2-199Date of registration: May 10, 2016

Certificated by VCCIMember No.3498Facility:966 Chamber: Registration No.: R-4045Facility:944 Shielded Room :Registration No.:C-4522Date of registration: September 10, 2016

Certificated by PHOENIX TESTLAB GmbHRegistration No.: 702860cDate of registration: May 11, 2016

Certificated by CNAS ChinaRegistration No.: CNAS L5783Date of registration: August 8, 2012

Name of Firm : Guangdong Keyway Testing Technology Co., Ltd.

Site Location : No.7 of Zhangmutou District, Guanzhang Road,Zhangmutou town, Dongguan Guangdong China.

Page 6: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 6 of 17

2.2.Test Summary

Test Item Condition Standard Result

Conducted disturbanceat mains terminals

150kHz to 30MHzFCC Part 15, Subpart BANSI C63.4:2014

N/A

Radiated Emission(below 1 GHz)

30MHz to 1GHzFCC Part 15, Subpart BANSI C63.4:2014

Pass

Radiated Emission(above 1 GHz)

Above 1GHzFCC Part 15, Subpart BANSI C63.4:2014

N/A

Remark: 1. The symbol “N/A” in above table means Not Applicable.2. Because the EUT employ battery power for operation and which do not operate from the ACpower lines or contain provisions for operation while connected to the AC power lines, so the testitem of Conducted disturbance at mains terminals is not applicable.3.When determining the test results, measurement uncertainty of tests has been considered.

System Measurement Uncertainty

Test Items Extended Uncertainty

Uncertainty for Radiated Emission in 3m chamber 3.60dB

Uncertainty for Conducted Emission. 2.60dB

Page 7: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 7 of 17

2.3.List of Test and Measurement Instruments

Equipment Manufacturer Model No. Serial No. Last Cal. Next Cal.For conducted emission at the mains terminals and load port testEMI Test Receiver Rohde&Schwarz ESCI 101156 Apr 12,19 Apr 11,20Artificial Mains Network Rohde&Schwarz ENV216 101315 Apr 12,19 Apr 11,20Artificial Mains Network(AUX)

Rohde&Schwarz ENV216 101314 Apr 12,19 Apr 11,20

RF Cable FUJIKURA 3D-2W 944 Cable Apr 12,19 Apr 11,20Voltage Probe CHWARZBECK A130302 KWE-053 Apr 12,19 Apr 11,20For radiated emission test (Below 1GHz)EMI Test Receiver Rohde&Schwarz ESCI 101156 Apr 12,19 Apr 11,20TRILOG BroadbandAntenna

SCHWARZBECK VULB 9168 00829 Apr 12,19 Apr 11,20

Spectrum Analyzer Agilent 8593E 3911A04271 Apr 12,19 Apr 11,203m Semi-anechoicChamber

ETS-LINDGREN 966 170326 Apr 12,19 Apr 11,20

Signal Amplifier SONOMA 310 186956 Apr 12,19 Apr 11,20RF Cable IMRO IMRO-400 966 Cable 1# Apr 12,19 Apr 11,20MULTI-DEVICEController

ETS-LINDGREN 2090 126913 N/A N/A

Antenna Holder ETS-LINDGREN 2070B 00109601 N/A N/AFor radiated emission test (Above 1GHz)EMI Test Receiver Rohde&Schwarz ESCI 101156 Apr 12,19 Apr 11,20Horn Antenna DAZE ZN30701 11003 Apr 12,19 Apr 11,20MXG Signal Analyzer Keysight N9020A MY56070279 Apr 12,19 Apr 11,203m Semi-anechoicChamber

ETS-LINDGREN 966 170326 Apr 12,19 Apr 11,20

Signal Amplifier ZHINAN ZN3380C 11001 Apr 12,19 Apr 11,20RF Cable IMRO IMRO-400 966 Cable 1# Apr 12,19 Apr 11,20MULTI-DEVICEController

ETS-LINDGREN 2090 126913 N/A N/A

Antenna Holder ETS-LINDGREN 2070B 00109601 N/A N/A

Note: Used Not Used

Page 8: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 8 of 17

3. TEST SET-UP AND OPERATION MODES

3.1.Principle of Configuration Selection

Emission: The equipment under test (EUT) was configured to measure its highestpossible radiation level. The test modes were adapted accordingly inreference to the Operating Instructions.

3.2.Block Diagram of Test Set-up

System Diagram of Connections between EUT and Simulators

(EUT: USB C HUB)

3.3.Test Operation Mode and Test Software

Refer to Test Setup in clause 4 & 5.

3.4.Special Accessories and Auxiliary Equipment

None.

3.5.Countermeasures to Achieve EMC Compliance

None.

TVPC EUT AC Mains

Page 9: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 9 of 17

4. TEST RESULTS

4.1.Conducted Emission at the Mains Terminals Test

Result : N/A

Test Site : 944 Shielded Room

Limits : FCC Part 15B

Frequency rangeMHz

Limits dB(μV)

Quasi-peak Average

0,15 to 0,50 66 to 56 56 to 46

0,50 to 5 56 46

5 to 30 60 50

NOTE: 1.The lower limit shall apply at the transition frequencies.2.The limit decreases linearly with the logarithm of the frequency in the range 0,15MHz to 0,50 MHz.

Test Specification

1.The EUT was put on a wooden table which was 0.8 m high above the ground andconnected to the AC mains through the Artificial Mains Network (AMN). Where themains cable supplied by the manufacture was longer than 1 m, the excess wasfolded back and forth parallel to the cable at the centre so as to form a bundle nolonger than 0.4 m.2.The EUT was kept 0.4 m from any other earthed conducting surface. Both sides ofAC line were checked to find out the maximum conducted emission levels accordingto the test procedure during the conducted emission test.3.The bandwidth of the test receiver was set at 9 kHz.

Test Set-up

Page 10: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 10 of 17

4.2.Radiated Emission Test (below 1 GHz)

Result : PASS

Test Site : 966 Chamber

Limits : FCC Part 15B

Frequency rangeMHz

Quasi-peak limits 3mdB(μV/m)

30-88 40

88-216 43.5

216-960 46

960-1000 54

Note: 1.The lower limit shall apply at the transition frequency.2.Additional provisions may be required for cases where interference occurs.

Conditional testing procedure

1.The EUT was placed on a turn table which was 0.8 m above the ground. The turntable can rotate 360 degrees to determine the position of the maximum emissionlevel. The EUT was set 3 m away from the receiving antenna which was mountedon an antenna tower. The measuring antenna moved up and down to find out themaximum emission level. It moved from 1 m to 4 m for both horizontal and verticalpolarizations.2.The highest frequency of the internal sources of the EUT is less than 108 MHz,the measurement shall only be made up to 1 GHz.3.The EUT was tested in the Chamber Site. It was pre-scanned with a Peakdetector from the spectrum, and all the final readings from the test receiver weremeasured with the Quasi-Peak detector.4.The bandwidth setting on the test receiver was 120 kHz.5.The worst test data were reported on the following pages.6.Emission Level = Antenna Factor + Cable Loss + Meter Reading - PreampFactor.

Test Set-up

Page 11: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 11 of 17

M/N : CB-C72Operation Mode : Mode 1Test Voltage : DC 5V From PCTest Specification : Vertical

Temperature (°C) : 24.9 Relative Humidity (%) : 56 Atmospheric Pressure(mbar) : 1015

Page 12: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 12 of 17

M/N : CB-C72Operation Mode : Mode 1Test Voltage : DC 5V From PCTest Specification : Horizontal

Temperature (°C) : 24.9 Relative Humidity (%) : 56 Atmospheric Pressure(mbar) : 1015

Page 13: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 13 of 17

4.3.Radiated Emission Test (above 1 GHz)

Result : N/A

Test Site : 966 Chamber

Limits : FCC Part 15B

Frequency rangeGHz

Average limitdB(µV/m)

Peak limitdB(µV/m)

1-3 50 70

3-6 54 74

Note: The lower limit applies at the transition frequency

Conditional testing procedure1.The EUT was placed on a turn table which was 0.8 m above the ground. The turn table canrotate 360 degrees to determine the position of the maximum emission level. The EUT was set3 m away from the receiving antenna which was mounted on an antenna tower. Themeasuring antenna moved up and down to find out the maximum emission level. It moved from1 m to 4 m for both horizontal and vertical polarizations.2.The EUT was tested in the 3m Chamber Site. It was pre-scanned with a Peak detector fromthe spectrum.3.The bandwidth setting on the test receiver was 1 MHz.4. Emission Level = Antenna Factor + Cable Loss + Meter Reading - Preamp Factor.

the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz,the measurement shall only be made up to 2 GHz.

the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz,the measurement shall only be made up to 5 GHz.

the highest frequency of the internal sources of the EUT is above 1 GHz, the measurementshall be made up to 5 times the highest frequency or 40 GHz, whichever is lower.

Test Set-up

Page 14: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 14 of 17

5. PHOTOGRAPHS OF TEST SET-UP

Radiated Emission Test (Below 1GHz)

Page 15: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 15 of 17

6. PHOTOGRAPHS OF THE EUT

Page 16: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 16 of 17

Page 17: TR19120435-E-000 USB C HUB FCC SDOC Report

Guangdong KeywayTesting Technology Co., Ltd. Report No. TR19120435-E-000 Page 17 of 17

***the end of the report***