+ All Categories
Home > Documents > Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new...

Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new...

Date post: 05-Aug-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
20
Tracers for remaining oil saturation determination Reservoir Surveillance and Monitoring FORCE seminar 13.09.2017 Sissel Opsahl Viig, Christian Dye, Alexander Krivocapic, IFE
Transcript
Page 1: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

Tracers for

remaining oil

saturation

determination

Reservoir Surveillance and MonitoringFORCE seminar 13.09.2017

Sissel Opsahl Viig, Christian Dye, Alexander Krivocapic, IFE

Page 2: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Who are we?

• Different tracer types

• How can tracers be used to gain information about the reservoir

• New possibilities

19.09.2017 2

Outline

Page 3: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

3

HSE

Helena BrobergADM

Jørgen Lundberg

President

Nils Morten Huseby

Dep. President

Atle Valseth

THE BOARD

Olav Fjell (Chairman)

Petroleum TechnologyMartin Foss

Safety Man-Technology-

OrganisationJon Kvalem

Isotope LaboratoriesBente Tange Harbø

Nuclear Technology, Physics

and SafetyAtle Valseth

Energy and Environmental

TechnologyArve Holt

Nuclear Waste ManagementHenning Refshauge Vahr

Communications and

Strategy

Silje Aspholm Hole

Page 4: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

vTracer timeline at IFE

• 1950ies Ground water, process equipment and different assignments for

local authorities

• 1983 Tracers for oil field applications

• 1986 First interwell tracer study at Ekofisk

• 1991 Development of chemical tracers for reservoir studies (Tracer

Club)

• 2001 Tracer studies of offshore process equipment

• 2005 Resman was established, partly based on IFE technology

• 2009 SPE award: For distinguished contribution to petroleum

engineering in the area of reservoir description and

dynamics

• 2012 Qualified tracers for Partitioning Interwell Tracer Test (PITT)

• 2013 Restrack was established, based on IFE technology

• 2016 Qualified tracers for Single Well Chemical Tracer Test (SWCTT)

4

Page 5: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• A tracer is injected into a system and can be followed through this

system and give information about it.

Different tracer categories:

• Passive tracers

• Partitioning tracers

• Reactive tracers

19.09.2017 5

A tracer gives information about a system

Page 6: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

Produced tracer

19.09.2017

Passive tracers in inter-well tracer tests map fluid

flow

6

Page 7: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Interwell tracer studies provides information about dynamic

properties of the reservoir:

• Preferential flow directions

• Horizontal and vertical communication between wells

• Permeability

• Sweep volumes

• Large-scale heterogeneities

Inter-well tracer tests (IWTT)

19.09.2017 7

Page 8: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

19.09.2017 8

Partitioning tracers are used in two different field

operations

PITT

Producer

Injector

SWCTT

5 - 10 m

Single Well Chemical Tracer Test – SWCTT

Partitioning Interwell Tracer Test - PITT

Page 9: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

Produced tracer

19.09.2017

Partitioning inter-well tracer tests (PITT) measure

SOR between wells

9

Page 10: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Identification of IOR/EOR targets

• Evaluation IOR/EOR operations/performance.

PITT tracers

19.09.2017 10

Page 11: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• 2013: Qualification of new group of PITT tracers

Viig et al, 2013; «Application of a New Class of Chemical Tracers to Measure Oil

Saturation in Partitioning Interwell Tracer Tests”, SPE 164059.

19.09.2017 11

PITT tracer development at IFE

PITT results:

₋ LAV-1: So = 24%

₋ LAV-2: So = 22%

₋ LAV-6: So = 11%

Core measurements LAV-1

₋ Zone A: 25%

₋ Zone B top: 28%

₋ Zone B base: 23%

Page 12: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Work continues:

19.09.2017 12

PITT tracer development at IFE

Temperature

Oil composition

Water salinity

K=CO/CW

Page 13: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

Produced tracer

19.09.2017

Single-well chemical tracer tests (SWCTT) measure

SOR in the near well zone

13

Page 14: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Identification of IOR/EOR targets

• Evaluation IOR/EOR operations/performance.

Single-well chemical tracer tests (SWCTT)

19.09.2017 14

Page 15: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• 2016: Qualification of new group of SWCTT tracers

Al-Abbad M., Sanni, M., Kokal, S., Krivokapic, A., Dye, C., Dugstad, Ø., Hartvig, S.,

Huseby, O., (2016) A Step-Change for Single Well Chemical Tracer Tests (SWCTT): Field

Pilot Testing of New Sets of Novel TracersField Pilot Testing of New Sets of Novel

Tracers, SPE-181408-MS.

What is new??

19.09.2017 15

SWCTT tracer development at IFE

Page 16: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

19.09.2017 16

SWCTT tracer development at IFE

Original method:

• 100-500 kg EtAc injected

• 100- 500 kg of IPA and NPA injected

• Injection time 1 day

• HSE

Page 17: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

19.09.2017 17

SWCTT tracer development at IFE

New method:

Status 2016:

• Four new tracer families (12 tracers)

• Injection amount 80g

• Pulse injection possible

Page 18: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

19.09.2017 18

New SWCTT tracers give new possibilities

Small K-value

Large K-value

Intermediate K-value

• Investigation depth depend on K-value. This gives

saturation estimate specific for each zone.

Cost-efficient data access

1. SoR

2. Fractional flow

3. Relative permeability

If «yes»

Page 19: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

• Studies have proved that tracers are a reliable tool to measure

remaining oil saturation.

• New tracers give new possibilities!

19.09.2017 19

Summing up

Page 20: Tracers for remaining oil saturation determination · 2019. 7. 3. · •2013: Qualification of new group of PITT tracers Viig et al, 2013; «Application of a New Class of Chemical

v

v

19.09.2017 20

Thank you!


Recommended