N17°51'50"E
45.72
N45
°03'
20"E
46.6
3
R=37.29A=9.46C=9.44N64°50'50"WN72°07'00"W
9.14
TRACINA DRIVE
(BY REGISTERED PLAN 1252)
N72°06'50"W
29.21
N44°54'00"W11.89
CHAIN LINK FENCE
CH
AIN LIN
K FENC
E
CH
AIN LIN
K FENC
E
83.91
83.48
83.53
83.61
83.59
84.4584.43
83.99
83.56
84.48
84.39
83.62
83.31
82.62
1ØD82.81
84.39
84.00EXIST.
WV83.94
83.84
84.32
83.59
83.46
0.2ØD
84.17
84.02
84.03 84.14
84.16
83.8083.78
83.6383.74
83.6583.63
83.49
84.01
0.06ØD
84.6384.69
84.60
84.58
84.68
84.61 84.52
84.48
84.36
83.64
83.37
83.40
83.56
83.44
83.40
84.52
84.58
84.68
84.53
84.53
84.33
83.75
83.73
83.77
84.59
84.64
84.52
84.45
0.1ØD
84.56
84.53
84.31
84.47
84.51
84.3584.42
84.6384.61
84.62
83.24
84.73
83.75
84.19
83.15
83.20
83.16
83.0083.25
83.26
82.80
82.49
82.24
82.12
82.76
82.76
82.22
82.86
82.51
82.44
82.39
82.41
82.98
83.10
83.02
81.99
82.49
82.72
82.21
82.08
82.55
82.61
82.61
82.70
6.0%
SLO
PE
GARAGE
COV'DPORCH
LOWERTERRACE
LOWERTERRACE
COV'DPORCH
1R
12R
PROPOSEDINGROUND
POOL
PAVERSTONEPATIO
HEDGE
PRECAST UNIT
RETA
INING WALL
RECONFIGUREDDRIVEWAY
LOW ADDRESS WALL
1R
1R1R
1R
1R
3R
3R
3R
3R
3R
FF 84.95
BF 81.59**UF 81.31
*TFW 84.59
PROPOSED2 STOREYDWELLING
No. 164
1R
PREC
AST
UN
ITIN
TER
LOC
KIN
GW
IND
OW
WEL
L
BUIL
T IN
PLAN
TER
BUILT INPLANTER
BUILT INPLANTER
LANDSCAPEPLANTER
REMOVE EXIST.1-STOREYDWELLING
HANDRAIL &GUARD AS PEROBC 9.8 & SB7
B/IBBQ
REMOVE EXIST.CONCRETE
POOL, PATIO &SUB BASE.
REINSTATE W/TOPSOIL & SOD.
REMOVE EXIST.ASPHALT DRIVEWAY &SUB BASE. REINSTATE
W/ TOPSOIL & SOD.
MH83.59
MH83.69
250mmØ SAN. SEWER @ 1.10% 250mmØ SAN. SEWER @ 1.10%
450mmØ STORM SEWER @ 1.10%
150mmØ WATERMAIN
300mmØ STORM SEWER @ 1.10%
SUMP PUMP TODISCHARGE TO
EXIST. STM.CONNECTION
REMOVE EXIST.WALKWAY & SUBBASE. REINSTATE
W/ TOPSOIL & SOD.
W
20mmWATERMETER
NEW
11.1-32mm
Ø C
OPPER
"K" WATER
SERVIC
E
EXIST. 25mm
Ø
WATER
SERVIC
E
EXIST. 9.9-125mm
Ø
SANITAR
Y SERVIC
E
NEW
11.7-125mm
Ø
SANITAR
Y SERVIC
E @ 1.0%
PAVERSTONEWALKWAY
PAVERSTONE
WALK
WAY
SUBJECT TO EASEMENT
AS IN 161922
EG 84.11
SOLIDHOARDING
CONSTRUCTION MATERIALSTORAGE AREA
THERE WILL BE NO CHANGE TOTHE EXISTING GAS AND HYDRO
UTILITIES, OR THEIR CONNECTIONTO THE DWELLING AS PART OF
THIS APPLICATION
CO
NST
RU
CTI
ON
ACC
ESS
EXTENT OF2ND FLOOR
EXTENT OF2ND FLOOR
EXIS
T. 1
25m
mØ
STO
RM
SER
VIC
E
SOLI
DH
OAR
DIN
G
EXTE
NT
OF
REV
ERSE
VEN
EER
AC
LOT 44SINGLE FAMILYRESIDENTIAL
LOT 42SINGLE FAMILYRESIDENTIAL
LOT 43REGISTERED PLAN 1252
1 STOREYBRICK DWELLING
No. 158
2 STOREYBRICK DWELLING
No. 168
3R
3R
AC
FRAMEDHOARDING
EXIST. "Y"CONNECTION
LOW ADDRESS WALL DETAIL
STONEVENEER
N.T.S.
164
COPINGCAP
FOUNDATION
1R
12R
1R
1R1R
1R
1R
3R
3R
3R
3R
3R
1R
General Notes:
no. date revision / comment
1 Issued To Owner For Building Permit Applic'nFeb 09/21
SP
Key Plan nts
1. Do Not Scale Drawings
2. These Plans Are To Remain The Property Of The Designer And Must Be Returned UponRequest. These Plans Must Not Be Used In Any Other Location Without The Written Approval OfThe Designer.
3. All Works To Be In Accordance With The Ontario Building Code And All Code References ReferTo O.B.C. 2012 Division 'b'
The Undersigned Has Reviewed And Takes Responsibility For ThisDesign, And Has The Qualifications And Meets The Requirements Set
Out In The Ontario Building Code To Be A Designer.
Name Signature BCIN
Firm Name BCIN
Peter Giordano 25061
DAVID W. SMALL DESIGNS INC. 29999Exempt Under Division C -3.2.4.1. Of the 2012 ONTARIO Building Code.
Qualification Information Required Unless The Design Is
Registration Information Required Unless The Design Is
Exempt Under Division C -3.2.5.1. Of the 2012 ONTARIO Building Code.
Base Information:
Base Information Taken From Plan Of SurveyBY: Traksick McMillan Kubicki Ltd.Dated: November 6, 2020
Location
Lot 43Registered Plan 1252Town Of OakvilleRegional Municipality of Halton
City Benchmark
Elevations Are Refereed To The Town OfOakville No. 36, Having An Elevation of90.284 Meters
*TFW (Top Of Foundation Wall)
Floor Sill Plate On Inside Face Of Foundation.- See Reduced Thickened Foundation Wall Detail& Reverse Veneer Detail For Foundation WallLedge Condition On Outside Face Of FoundationWalls.- Extent Of Each Type To Be Determined ByContractor On Site During Construction
Regional Approval
METAL T-BARSUPPORTS
1x3 TOP RAIL
Tree Protection Barriet Detail nts
PLASTIC SAFETYFENCING
GRADE
6'-7"
4'-0
" 2.0% Minimum 2.0% MinimumSWALE
Minimum Depth = 150mmMaximum Depth = 250mm
3:1Max Max
3:1CL
Typical Swale Detail nts
Prop
erty
Lim
itM
atch
Gra
des
XXXXXXXXXX XXXXXXXXXX
Dep
th
Gr a ss
All Supports And Bracing Should Be Outside The Tree Protection Zone. All Such Supports Should MinimizeDamaging Roots Outside The Tree Protection Barrier.
No Construction Activity, Grade Changes, Surface Treatment Or Excavation Of Any Kind Is Permitted WithinThe Tree Protection Zone.
4
5
Tree Protection Barriers For Trees Situated On The Town Road Allowance Where Visibility Must Be MaintainedCan Be 1.2m (4ft.) High And Consist Of Orange Plastic Web Snow Fencing On A Wood Frame Made Of 2x4's.
Where Some Excavate Or Fill Has To Be Temporarily Located Near A Tree Protection Barrier, Plywood Must BeUsed To Ensure No Material Enters The Tree Protection Zone.
2
3
Tree Protection Barriers
Tree Protection Barriers Must Be 1.2m (4ft.) High, Waferboard Hoarding Or An Equivalent Approved By UrbanForestry Services.
1
Waferboard Or AsApproved By UrbanForestry Services
2
1 21 3
Snow Fencing4
5
Region Design Of Water &/or Wastewater Services Approval Subject To DetailConstruction Conforming To Halton Region Standards & Specifications &Location Approval From Area Municipality.
Signed: _______________________ Dated: ______________________Infrastructure Planning & Policy
The Approval Of The Water System On Private Property Is The Responsibility Of, The LocalMunicipality, Regardless, The Applicant Must Ensure That The Region Of Halton's StandardsAre Met. (The Water And Wastewater Linear Design Manual May Be Obtained On Halton.caOr By Calling 311) All Water Quality Tests Must Be Completed To The Region Of Halton'sSatisfaction Before The Water Supply Can Be Turned On.
Underground Utilities:
The Location Of Underground Services ShownOn This Plan Is Only Approximate And Is ForPlanning And Design Purposes Only. ThisInformation Must Not Be Assumed To BeComplete Or Up-To-Date And An On-Site LocateMust Be Ordered Prior To Any Excavation. DavidW. Small Designs Inc. Accepts No ResponsibilityFor Any Claims Or Losses Due To Improper UseOf This Information.
Notes:
There Are To Be No Grad Changes Within 0.3mOf Common Property Lines
The Existing Sanitary Lateral Must Be Inspectedat The property Line By Regional Inspector, AndTelevised By Regional Forces Prior ToConnection. A Lateral That Does Not MeetCurrent Regional Standards Must BeDissconnected At The Main. A Revision To TheService Permit Drawings And Payment OfApplicable Fees Is Required.
Existing Services Must Be Disconnected At TheMain By The Contractor
All Water And Sanitary Main Taps Are To BePreformed By Region Of Halton Forces Only
Contractor To Determine Existing Inverts AndReport Any Discrepancies To The Engineer
Contractor To Determine San. Inverts On SiteAnd Determine If San. Ejector Pump Is Required
House Footprint
Front Porch
Rear Porch
Total Coverage
282.45 sm
7.12 sm
47.33 sm
336.90 sm24.46%
Lot Coverage
Site Data
Lot Area (0.137 ha)Zoning RL2-0Established Grade 84.11
Floor AreaGround Floor 2297.4 sf(Includes 71.2 sf of Stairs)Second Floor 2181.8 sf(Includes 71.2 sf of Stairs & Excludes 99.2 sf of O.T.B)
213.43 sm
202.69 sm
Total Area 4479.2 sf416.12 sm
Garage 652.0 sf60.57 sm
1377.53 sm
(Measured to Inside Face of Garage Walls)Finished Basement 2255.4 sf209.53 sm(Measured to Inside Face of Finished Basement Walls)
Proposed Footprint 282.45 sm20.50%(Including Garage)Proposed Covered Porches 54.45 sm3.95%
Total Proposed Coverage 336.90 sm24.46%Max Allowed Coverage 344.38 sm25.00%
Lot Coverage
FSI = 0.30
SITE
**U/F (Under Side of Footing)
- U/F Denotes Minimum Depth Of Under Sideof Footing.- Under Side of Footing May DifferDepending On Basement Conditions. SeeFloor Plans And Elevations For SpecificUnder Side Of Footing Conditions .- Footings To Be Min 1.2m Below Grade
THE EXISTING SANITARY SERVICE LATERALMUST BE INSPECTED AT THE PROPERTY LINEBY THE REGIONAL INSPECTOR AND TELEVISEDBY REGIONAL FORCES PRIOR TO CONNECTION
NOTE: CONTRACTOR TO DETERMINEEXISTING INVERTS AND REPORT ANYDISCREPANCIES TO THE ENGINEER
STORM INVERT @ MAIN UNKNOWN. IT IS THEBUILDER'S RESPONSIBILITY TO ENSUREGRAVITY FLOW FROM PROPOSED BASEMENTFLOOR ELEVATION. IF A GRAVITY CONNECTIONCANNOT BE ACHIEVED FROM THE PROPOSEDBASEMENT FLOOR ELEVATION A SUMP PUMP ISTO BE INSTALLED AS PER OBC + MUNICIPALREQUIREMENTS.
Legend
3R
102.05
AC
102.05
Main Level
Property Line
Existing Spot Elevation
Proposed Spot Elevation
Rainwater Downspouts
Air Conditioner
Solid Hoarding
Framed Hoarding
(with trunk diameter)0.30ØC
102.05
0.30ØC
102.05
Denotes Coniferous Tree
To Remain
(with trunk diameter)Denotes Deciduous Tree
To Remain
(with trunk diameter)Denotes Tree
To Be Removed
Native Species Min 60mmDenoted Replacement Tree
Caliper For Deciduous And
0.30ØC
102.05
1.8m Height For Coniferous
SM
(SM) Refers To Sugar Maple(RM) Refers To Red Maple
AD Area Drain
3R Lower Level
Existing To Be Removed
Lot Coverage Diagram 1:300
Site PlanDrawing:
Scale:
Date:
Dwn by:
Proj. no.:
Project:
Feb 2021
HD
20-1855
164 Tracina DriveThe Squire Home
Town of Oakville,Regional Municipality of Halton
Lot 43Registered Plan 1252
1:100
davidsmalldesigns.com
Tracina Dr
Third Line
Lakeshore Rd W
Rebec
ca S
t
Hixon S
t
Average Grade Diagram nts
Average Grade CalculationWall No.
123456
Total
Wall Average Grade Wall Length (m) Product
Average Grade =
84.6084.6584.5483.2682.6182.52
751.58
12.316.72
11.843.963.80
11.89
75.78
1041.43568.85
1000.95329.71313.90981.16
6338.27
Total Product Divided By Total Wall Length =83.64
7 82.66 5.61 463.728 82.77 9.55 790.499 83.97 10.10 848.06
Average Grade 83.64