Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4018D1000AA
TAG: _________________________________
1.5 Ton Split SystemAir Conditioner - 1 Phase M4AC4018D1000AA
SUBMITTAL
M4AC4018D1000AA208/230/1/60
10.415
SCROLL1 - 1
208/230/1/607.7 - 48.0
NOPROPELLER
17-3/4 - 1
16001 - 1/81075
208/230/1/600.70
PLATE FIN2 - 21 8.93/16
ORIFICE
5 LBS. - 2 OZ.YES3/43/8
8º FW X H X D
22-9/10x26-1/4x22-9/10
128121
NONO
M4AC4018D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 554 (21-7/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
554 (21-7/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
DIRECT-1
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4024D1000AA
TAG: _________________________________
2.0 Ton Split SystemAir Conditioner - 1 Phase M4AC4024D1000AA
SUBMITTAL
M4AC4024D1000AA208/230/1/60
13.420
SCROLL1 - 1
208/230/1/6010.1 - 52
NOPROPELLER
18-7/8 - 1
18001 - 1/8 1075
208/230/1/600.7
PLATE FIN2 - 21103/16
ORIFICE
5 LBS. - 5 OZ.YES3/43/8
8º FW X H X D
24-7/10x26-1/4x24-7/10
139132
NONO
M4AC4024D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 600 (23-5/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
600 (23-5/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
DIRECT-1
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4030D1000AA
TAG: _________________________________
2.5 Ton Split SystemAir Conditioner - 1 Phase M4AC4030D1000AA
SUBMITTAL
M4AC4030D1000AA208/230/1/60
14.725
SCROLL1 - 1
208/230/1/6010.9 - 63
NOPROPELLER
23 - 1DIRECT-1
26501 - 1/6 825
208/230/1/601.0
PLATE FIN2 - 21133/16
ORIFICE
5 LBS. - 12OZ.YES3/43/8
8º FW X H X D29x26-1/4x29
157148
NONO
M4AC4030D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 710 (28) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4036D1000AA
TAG: _________________________________
3.0 Ton Split SystemAir Conditioner - 1 Phase M4AC4036D1000AA
SUBMITTAL
M4AC4036D1000AA208/230/1/60
19.430
SCROLL1 - 1
208/230/1/6014.7 - 75
NOPROPELLER
23-5/8 - 1DIRECT-1 2700
1 - 1/6 825
208/230/1/601.0
PLATE FIN1 - 21
143/16
ORIFICE
5 LBS. - 14OZ.YES3/43/8
8º FW X H X D
30-1/5x26-1/4x30-1/5
163154
NONO
M4AC4036D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 740 (29-1/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
740 (29-1/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4042D1000AA
TAG: _________________________________
3.5 Ton Split SystemAir Conditioner - 1 Phase M4AC4042D1000AA
SUBMITTAL
M4AC4042D1000AA208/230/1/60
21.635
SCROLL1 - 1
208/230/1/6015.9 - 112.3
NOPROPELLER
23 - 1DIRECT-1
37001 - 1/31075
208/230/1/601.70
PLATE FIN2 - 21
173/16
ORIFICE
7 LBS. - 16OZ.YES3/43/8
8º FW X H X D29x34-1/2x29
201190
NONO
M4AC4042D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4AC4048D1000AA
TAG: _________________________________
4.0 Ton Split SystemAir Conditioner - 1 Phase M4AC4048D1000AA
SUBMITTAL
M4AC4048D1000AA208/230/1/60
24.640
SCROLL1 - 1
208/230/1/6018.3 - 108
NOPROPELLER
23 - 1DIRECT-1
37001 - 1/31075
208/230/1/601.70
PLATE FIN2 - 21173/16
ORIFICE
7 LBS. - 16OZ.YES7/83/8
8º FW X H X D29x34-1/2x29
201190
NONO
M4AC4048D1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 7/8
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Literature Order Numbe r SS-PRC007-EN
File Numbe r —
Supersede s SS-PRC007-EN 2/0 2
Stocking Locatio n PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Revised 09/24/17
P ro d u c t S p e c i f i c a t i o n s O U T D O O R U N I T P O W E R C O N N S . — V / P H / H Z M I N . B R C H . C I R . A M P A C I T Y B R . C I R . P R O T . R T G . - M A X . ( A M P S ) C O M P R E S S O R N O . U S E D - N O . S P E E D S V O L T S / P H / H Z R . L . A M P S - L . R . A M P S F A C T O R Y I N S T A L L E D S T A R T C O M P O N E N T S I N S U L A T I O N / S O U N D B L A N K E T C O M P R E S S O R H E A T O U T D O O R F A N D I A . ( I N . ) - N O . U S E D TY P E D R I V E - N O. S P E E D S C F M @ 0 . 0 I N . W . G . N O . M O T O R S - H P M O T O R S P E E D R . P . M . V O L T S / P H / H Z F . L . A M P S O U T D O O R C O I L — T Y P E R O W S - F . P . I . F A C E A R E A ( S Q . F T . ) T U B E S I Z E ( I N . ) R E F R I G E R A N T C O N T R O L R E F R I G E R A N T L B S . — R - 4 1 0 ( O . D . U N I T ) F A C T O R Y S U P P L I E D L I N E S I Z E - I N . O . D . G A S L I N E S I Z E - I N . O . D . L I Q . C H A R G I N G S P E C I F I C A T I O N S U B C O O L I N G D I M E N S I O N S C R A T E D ( I N . ) W E I G H T S H I P P I N G ( L B S . ) N E T ( L B S . )
M4AC4060C1000AA
TAG: ____________________________ _ _ _ _ _
5.0 T o n S p l i t S y s te m A i r Conditioner - 1 Phase M4AC4060C1000AA
S U B M I T T A L
M4AC4060C1000AA2 0 8 / 2 3 0 / 1 / 6 0
29.650
S C R O L L 1 - 1
2 0 8 / 2 3 0 / 1 / 6 0 22.3 - 127.9
N O PROPELLER 23-5 / 8 - 1D I R E C T - 1
1 - 1 / 3 107 5
2 0 8 / 2 3 0 / 1 / 6 0 1.70
PLATE FIN 3 - 2118.4 3/16
O R I F I C E
7 L B S . - 12O Z . Y E S 7 / 8 3 / 8
8 º F W X H X D
30-1 / 5 x 34-1 / 2x30-1 / 5
214203
N O N O
M4AC4060C1000AA
M o d e l H W L L I Q U I D V A L VE S I Z E GAS V A L VE S I Z E
84 3 (33-3/16) 740 (29-1 / 8 ) 3 / 8 7 / 8
A m e r i s t a r
NOTE: All dimensions are in mm/inches.
740 (29-1 / 8 )
SUCTION LINE CONNECTION
CONTRO L WIRING 7/8” (22.2mm)
KNOCKOU T 1- 1 1/32” (34.5mm)
LIQUID LINE CONNECTION
SE R VICE FITTING
SE R VICE FITTING
POWER WIRING SEE DE T AI L A
DE T AI L A
HOLE 1-3/32” (27.8mm)
NOTE: GRIL L APPEARANCE M A Y V A R Y .
SE R VICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED P ANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS V A L VLE FOR LOW PRESSURE NOTE: ON L Y ADOPTED B Y HE A T PUM P , CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER V A L VE-SUCTION T O COMPRESSOR OR REFRIGERAN T CHARGE.
3800
Literature Order N um be r SS-PRC007-EN
File Num be r —
Supersede s SS-PRC007- EN 2/0 2
Stocking Locatio n PI Louisville & W ebb/M ason H ouston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesLiquid line drier —
Ameristar
The M4AC40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.