+ All Categories
Home > Documents > Transmission Electron Microscopy Visualization Techniques

Transmission Electron Microscopy Visualization Techniques

Date post: 23-Feb-2016
Category:
Upload: cachez
View: 43 times
Download: 2 times
Share this document with a friend
Description:
Transmission Electron Microscopy Visualization Techniques. Bob Ashley AAS SMFW 7-13-2013. Reading List. Reading List Negative Staining 1990 Hayat and Miller - PowerPoint PPT Presentation
Popular Tags:
35
Transmission Electron Microscopy Visualization Techniques Bob Ashley AAS SMFW 7-13-2013
Transcript
Page 1: Transmission Electron Microscopy Visualization Techniques

Transmission Electron Microscopy

Visualization Techniques

Bob Ashley AAS SMFW

7-13-2013

Page 2: Transmission Electron Microscopy Visualization Techniques

Reading List

• Reading List • Negative Staining 1990 Hayat and Miller• Baker, T. S., and R. Henderson (2006). Electron

cryomicroscopy. In "International Tables for Crystallography", Vol. F, ch. 19, pp. 451-463. Baker, T. S., and R. Henderson (2006).

• Baker, T. S., N. H. Olson, and S. D. Fuller (2000) Erratum: Adding the third dimension to virus life cycles: Three-Dimensional reconstruction of icosahedral viruses from cryo-electron micrographs. Microbiol. Molec. Biol. Reviews 64:237.

Page 3: Transmission Electron Microscopy Visualization Techniques

Overview

• Free will vs. Determinism in electron microscopy

• Two methods of viewing in TEM• Cryo and Negative Stain

Page 4: Transmission Electron Microscopy Visualization Techniques

Grids and Support Film

• Usually Copper• How does it react with the specimen?

• Mesh indicates amount of open area• Higher number less open 50-1000• We use 400 mesh square• Very thin films and specimens

• Hexagonal shape openings

• Very delicate• Even mild bend or buckle can cause distortion of specimen or focus aberration

Page 5: Transmission Electron Microscopy Visualization Techniques

Grid Types• Supports used must be strong yet electron transparent

• Plastic (formvar)• Carbon• Holey carbon• Quantifoil• C-flat

Page 6: Transmission Electron Microscopy Visualization Techniques

Support Film Concerns

• Mass thickness influences contrast while mechanical stability increases image clarity• Films in general must have• High transparency• Adequate strength to withstand

E- beam and support specimen

• Carbon coated only (6-10 nm)• Uniformly amorphous• More elastic scattering events

with e- beam• Can be stable very thin 1-2nm • More stable than plastic alone• Hydrophobic, fragile, time

consuming to make

• Plastic only 10-20nm (10-20 nm)• Formvar• More clarity with less

background than Carbon alone

• Not as thermally stable and can cause charging and drift

• Carbon Coated with Plastic• Stability of carbon but will

have a thickness that may impede resolution

Page 7: Transmission Electron Microscopy Visualization Techniques

All Sides Being Equal?• Dull Side (coppery)

• More area for film to adhere

• Shiny side (polished)• Not as much surface

area for films to adhere• Can cause movement

under e- beam exposure

Page 8: Transmission Electron Microscopy Visualization Techniques

To Glow or NotGlow Discharge renders continuous carbon coated grids hydrophilic by applying a negative charge.

• Aids stain spread more uniformly (increases wettability)• Helps particles in specimen to adhere to the substrate• Decreases likelihood of the virus particles being held in

aggregates as a result of the interaction between the virus particles and the surface charge of film

Page 9: Transmission Electron Microscopy Visualization Techniques

Contrast• Two types in electron microscopy• Amplitude contrast (scattering contrast)• Subtractive effect where various shades are evident by

loss of electrons • Main source of most electron microscope contrast (except

cryo)

• Phase Contrast (interference contrast)• Interference of diffracted waves cause intensity

differences due to loss of energy and the corresponding shorter focal points• Appear as bright ring or halo around the edge of an object• Fresnel ‘freh-nell’ fringe

Page 10: Transmission Electron Microscopy Visualization Techniques

The Concept of Negative Stain• Heavy metal atoms act as barrier to the e- beam• Allows passage through specimen

• Stain penetration into hydrophilic specimen• Dries faster than specimen• Mostly hydrated regions replacing water• Lipoproteins and proteins

• Stains form around hydrophobic regions including lipid• Contrast dependent on stain thickness • Resolution range 20-40 Å

Page 11: Transmission Electron Microscopy Visualization Techniques

Negative Contrast• Dense areas are bright also exclude stain

• Amplitude contrast• Areas with no stain appear light because there is nothing for the electron beam to hit and the transmitted electrons shine through

Page 12: Transmission Electron Microscopy Visualization Techniques

Simple Microscopy

• Lighter areas have more protein and exclude stain• Darker areas are where the stain pools

• Indent in support mechanism

Page 13: Transmission Electron Microscopy Visualization Techniques

Stain Film and Particle Interactions

A. Hydrophilic specimen hydrophilic film

B. Hydrophilic specimen on hydrophobic film

C. Hydrophobic specimen on hydrophilic film

D. Hydrophobic specimen on hydrophobic film

Page 14: Transmission Electron Microscopy Visualization Techniques

Negative and Positive Staining

A. 4% PTA Negative Stained B. 4% UA Positive StainedC. 4% UA Negative Stained

• Three types of staining visible• Negative staining appearing

white• Negative staining appearing

grey• Positive staining appearing

black• Severe structural

distortion

Page 15: Transmission Electron Microscopy Visualization Techniques

Staining Methods

Page 16: Transmission Electron Microscopy Visualization Techniques

Factors Controlling Appearance

• Specimen• pH• Isoelectric Point• Fixation• Concentration

• Stain • pH• Charge• Buffer and specimen

interaction• Osmolarity• Can influence structure

and volume of particle

• Interaction with the support mechanism• Grid film• Thickness of stain on film• Charge and beam

interactions

Page 17: Transmission Electron Microscopy Visualization Techniques

The Effect of the Isoelectric Point of Protein and Stain

• Isoelectric point (pI) or (IEP)

• The pH at which a particular molecule or surface carries no net electrical charge

• Can be time dependent and is not absolute

• Fixation with glutaraldehyde increases net negative charge

• The presence of a fixed negative or positive charge influences the deposition of any given stain• In general proteins• Combine (positive stain) with cations (UA+) on the alkaline side of the

pI• Combine with anions (PTA-) on the acidic side of the pI

• Protein pI• Stain pH greater than pI applies negative charge• Stain pH lower than pI applies positive charge• Ex. Protein with a pI of 5.0 is negatively charged at pH 7.0 with PTA-

which is higher than the pI of the protein therefore the stain repels and is excluded by the protein

Page 18: Transmission Electron Microscopy Visualization Techniques

Other Effects of pH• Optimal pH for stains is not known but each has a

satisfactory range• At high pH the stain penetration is usually enhanced

with long stain time• At low pH the surface detail is usually highlighted due to

acidic environment

• May change with stain storage and with stain drying• Use fresh stain preferable and check before staining

specimen Ex. stained with PTA at 5.0 pH, influenza virus surface spikes well preserved same sample stained with 7.5 pH PTA stain penetrates virus envelopeEx. PTA with pH of 4.5 recommended for resolving antibody particles bound to rotavirus

Page 19: Transmission Electron Microscopy Visualization Techniques

Negative Stains

• Negative stain should:• Have minimal interaction with specimen (pos. stain)• High solubility in solution (precipitates and crystalizes in

e- beam)• High density (must be at least twice the density of the

specimen to be visualized)• High melting point to avoid beam damage• Small grain size• Chemical pH stability

Page 20: Transmission Electron Microscopy Visualization Techniques

Types of Stains• Uranyl Acetate+ (cation)

• Most widely used• Density of 2.87 g/cm^3• Ion diameter .4-.8 nm• pH of 4.0-5.5 (usually used at

4.5 unstable at 6.0)• Concentrations .5-5% ideal as

1%• Can act as fixative• Higher contrast than PTA• Stabilizes lipids therefore may

minimize drying effect of virus particles

• Uranyl Oxalate+(cation)• Can be used in pH from 5.0-7.0

(ideal at 6.5-6.8)• Desirable for pH sensitive

specimens• Provides the contrast and

penetration of UA without the acidity

• Desirable for virus proteins below the pI or low molecular weight

• Uranyl Formate+(cation)• Smallest grain size for better

penetration of interstices of sample• Useful for high-res• pH of 4.0-5.5 (usually used around

4.5)• Density of 3.68 g/cm^3• Ideal as .75%

Page 21: Transmission Electron Microscopy Visualization Techniques

Types of Stains Continued• PTA-(anion)

• Along with UA most widely used• Density 4 g/cm^3• Grain size of 1.2 nm (not useful for high res work)• At neutral pH very little interaction with the specimen (avoids most positive

staining)• Very stable in e- beam• Will not fix a specimen• Not stable over time with storage <1 month• May dissociate quaternary proteins into small units

• Ammonium Molybdate• Used for osmotically sensitive specimens• pH from 5.0-8.0 useful at 7.0-7.4• Higher contrast than PTA

• Methylamine Tungstate (NanoW)• pH 6.4-7.0• Tolerates concentrated buffers

Page 22: Transmission Electron Microscopy Visualization Techniques

Drawbacks of Negative Stain• Fixation

• Tends to concentrate sample

• Cellular debris and other junk

• Positive staining

• Beam irradiation• Lower kV=more damage potential

• Drying• Leads to distortion of particle

• Flattening• Will usually happen perpendicular to support mechanism• Makes sample typically larger in diameter to known size

Page 23: Transmission Electron Microscopy Visualization Techniques

Cryo EM• Negative Stain • Cryo

Contrast reversal of negative stain, dark areas indicate density- Phase Contrast

Light areas indicate density

• Cryo Fixation Advantages• Keeps sample in near native state

Higher resolution – 8-15 Å• No artifacts from stain

Page 24: Transmission Electron Microscopy Visualization Techniques

Types of Ice

• Amorphous or glassy ice • Target state of cryoEM samples• Liquid nitrogen -195° C• Heat capacity too low- Liedenfrost Effect• Liquid ethane • Liquid propane

• Cubic ice• Water in crystalline lattice obscures beam• Usually around -140° C

• Vanilla Ice• Too hot to handle yet too cold to hold

Page 25: Transmission Electron Microscopy Visualization Techniques

The Grid in Cryo

Page 26: Transmission Electron Microscopy Visualization Techniques

The Mechanism• Plunge Freezing • Manual Blotting

Page 27: Transmission Electron Microscopy Visualization Techniques

Advanced Grid Freezing- Gatan CP3

Page 28: Transmission Electron Microscopy Visualization Techniques

Visualizing Ice on the Grid

Search for suitable area on grid

Page 29: Transmission Electron Microscopy Visualization Techniques

Low Dose

• Ice is beam sensitive• E- cause irradiated sample• High res data can be lost in a matter of seconds

• Focus on area that is not photographed and correct for astigmatism

• Keep levels to around 5-20 E/A^2• Can be a software automated process

Page 30: Transmission Electron Microscopy Visualization Techniques

Visibility of Particles

Page 31: Transmission Electron Microscopy Visualization Techniques

Irradiation Damage

Page 32: Transmission Electron Microscopy Visualization Techniques

Defocus Tradeoff• Focus adjacent region of interest to true focus• No inherent contrast from sample in ice• No tone ring visible in FFT• Reset to range desirable -2 to -5 ųm

Page 33: Transmission Electron Microscopy Visualization Techniques

Drawbacks of Cryo EM

• Low contrast

• Expensive

• Time intensive

• Labor intensive

• Beam irradiation• Lower kV=more

damage potential

• Low signal to noise ratio

• Size limitation• Must be > 400kD for proper

resolution• Smallest published to date is 260kD• Cryo negative stain as possible

solution• Phase plates

Page 34: Transmission Electron Microscopy Visualization Techniques

The End Result

Page 35: Transmission Electron Microscopy Visualization Techniques

Thank You

Try the best you can to achieve your EM dreams!


Recommended