CR 10
83
FORK PANTHER CREEK
BRANCH OF SOUTHSTA. 2+24.56
END PROJECT
STA. 0+56.75
BEGIN PROJECT
@ 0° SKEW
COMPOSITE DECK BRIDGE
1-SPAN CB 12X48 PPC
STA. 1+62.28 CONST.
CONCRETE COATING
69 EMBANKMENT AT BRIDGE END BENT STRUCTURES
SEPIA 027
SEPIA 028 STEEL GUARDRAIL POSTS
STEEL BEAM GUARDRAIL ("W" BEAM)
SEPIA 032
SEPIA 034
SEPIA 035
DELINEATORS FOR GUARDRAIL
GUARDRAIL END TREATMENT TYPE 7
RAILING SYSTEM TYPE II GUARDRAIL TREATMENT
RBI-002-07 TYPICAL GUARDRAIL INSTALLATIONS
GUARDRAIL COMPONENTS
RBR-016-05 TIMBER GUARDRAIL POSTS
BGX-006-10 STENCILS FOR STRUCTURES
BDP-001-05
BDP-002-03
BDP-003-03
BDP-004-03
BDP-005-05
BJE-001-13
BOX BEAM BEARING DETAILS
BOX BEAM GENERAL NOTES & REFERENCES
BOX BEAM MISCELLANEOUS DETAILS
BOX BEAM TENSION ROD DETAILS
RAILING SYSTEM TYPE II
NEOPRENE EXPANSION DAM AND ARMORED EDGES
RDI-040-01 EROSION CONTROL BLANKET SLOPE INSTALLATION
RDX-210-03 TEMPORARY SILT FENCE
RDX-220-05
RDX-225-01
SILT TRAP A
SILT TRAP B
RGX-001-06 MISCELLANEOUS STANDARDS
RETAINING WALL GRAVITY TYPE NON-REINFORCED
RGX-200-01 ONE POINT PROCTOR FAMILY OF CURVES
RGX-002-09
BDP-006-04 BOX BEAM B12 & CB12 DETAILS
SEPIA 009
SEPIA 010
TREATMENT OF EMBANKMENT AT END BENTS
TREATMENT OF EMBANKMENT AT END BENTS-DETAILS
ROLLING
STANDARD DRAWINGSE-S
HE
ET
NA
ME:
R0010
0LS
Micro
Statio
n v8.11.7.443
DESIGN CRITERIA
DESIGNED
CLASS OF HIGHWAY
TYPE OF TERRAIN
DESIGN SPEED
REQUIRED NPSD
REQUIRED PSD
LEVEL OF SERVICE
DHV
D %
T %
% RESTRICTED SD
LEVEL OF SERVICE
MAX. DISTANCE W/O PASSING
LATITUDE DEGREES
LONGITUDE SECONDS WEST
SECONDS NORTH
DEGREES
ADT PRESENT ( )
ADT FUTURE ( )
GEOGRAPHIC COORDINATES
RURAL LOCAL
2006105
MINUTES
MINUTES
36
49
38
4086
37
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME: ...\d014
7571\
Lay
out
Sheet.dgn
12:18:38
AM
agille
y
1/4/2019
ACTIVE SEPIAS
PREPARED BY
OHIO
2-10015
Construction.2012 Standard Specifications for Road and Bridge
NUMBER:
LETTING DATE:
PROJECT
COUNTY OF
Commonwealth of KentuckyDEPARTMENT OF HIGHWAYS
FEBRUARY 22, 2019
ITEM NO.
DRAWING NO.27867
Current Interims.2017 AASHTO LRFD Bridge Design Specifications with
STATE HIGHWAY ENGINEER
PROJECT MANAGER
RECOMMENDED BY:
DATE:
DATE:
PLAN APPROVED BY:
LOCATION MAP
INDEX OF SHEETSSheet No. Description
PLAN SHEET
PROFILE SHEET
GENERAL NOTES
LAYOUT SHEET
TYPICAL SECTION
PILE RECORD
PILE END BENTS 1&2
MAINTENANCE OF TRAFFIC
R3
R4
S1
S2
S3
S4
S5
S6
TYPICAL SECTION SHEET
TITLE SHEET
COUNTY OF ITEM NO. SHEET NO.
OHIO 2-10015 R1
CONTRACT COMPLETION DATE AND LIQUIDATED DAMAGES
TRAFFIC CONTROL
PLACING BRIDGE OVERLAY APPROACH PAVEMENT
PORTABLE CHANGEABLE MESSAGE SIGNS
EROSION PREVENTION AND SEDIMENT CONTROL
SPECIAL NOTES
SPECIAL PROVISIONS
SPECIFICATIONS
TRANSPORTATION CABINETDEPARTMENT OF HIGHWAYS
STA. 1+62.28BRANCH OF SOUTH FORK PANTHER CREEK
ROCKY CREEK LANE (CR 1083) OVEROHIO COUNTY
SEPIA 031ANCHOR
GUARDRAIL END TREATMENT TYPE 7 ALTERNATE
BPS-003-09 HP12X53 STEEL PILE
EXISTING BRIDGE ID: 092C00097N
BRIDGE DEMOLITION
RBR-005-11
RBM-115-10 CONCRETE BARRIER WALL TYPE 9T (TEMPORARY)
SEPIA 024 TYPICAL GUARDRAIL INSTALLATIONS
SEPIA 021 CRASH CUSHION TYPE VI-BT
R1
R2
R5 TRAFFIC CONTROL PLAN
TREE CLEARING RESTRICTION
TA C
K
S Y
F
TEO NKE
TU
N
E
O
R
S
EF
O
ISCI
L
P
LA
RE
E
D
ESN
ENI
GN
24751
WILLIAM
GILLEY
ANDREW
TA C
K
N
E
O
R
S
EF
O
ISCI
L
S
P
LA
RE
E
D
ESN
ENI
GN
Y
F
TEO NKE
TU
28391
MICHAEL J.
VICKERS
CONVENTIONAL SIGNS
SURVEY LINE
GRADE LINE
GROUND LINE
COUNTY LINE
CORPORATE LIMITS
PROPOSED RIGHT OF WAY
BENCH MARK
RAILROAD
FENCE (CONTROLLED ACCESS)
FENCE (EXCEPT STONE AND HEDGE)
TREES
PIPE CULVERT
CULVERT
BRIDGE
BUILDINGS
LIGHTING POLE
POWER POLE
JOINT POWER & TELEPHONE POLE
TELEPHONE & TELEGRAPH POLE
ANCHOR, POWER OR TELEPHONE
STUB POWER
STUB TELEPHONE
WATER MAIN
GAS MAIN
TELEPHONE DUCT
ELECTRIC DUCT
DIRECT BURIAL ELECTRIC CABLE
DIRECT BURIAL TELEPHONE CABLE
STONE FENCE
HEDGE FENCE
SWAMP OR MARSH
SPRINGS
QUARRY SITE
LAKES OR PONDS
NORTH POINT
GUARDRAIL
SINKHOLE
400’ V.C.
B.M. NO.4
1-S
FRAME
1-S
BRICK SHED
2-S
BRICK
TERMINALSECTION
GUARDRAILEND TREATMENT
EXISTING PROPOSED
E E
T T
EXISTING ROAD
TRAFFIC LIGHTS
T
E
SAN
STORM
DIRECT BURIAL TV CABLE TV
E
T
SANITARY SEWER (WITH MANHOLE)
STORM SEWER (WITH MANHOLE)
GM
WM
T
E
TV
SAN
STORM
EXIST. RIGHT OF WAY & PROPERTY LINE
RIGHT OF WAY MONUMENT
RIGHT OF WAY MONUMENT
WM6"
GM6"
UTILITY TEST HOLE
EXIST. PROPERTY LINE PL
OVERHEAD WIRE
ELECTRIC MANHOLE EMH EMH
BLUE LINE STREAM
OR DITCH
INTERMITTENT STREAM
REGULATED FLOODWAY
EXISTING R/W MARKER
TELEPHONE MANHOLE TMH TMH
TREE LINE
THEXISTING/ PROPOSED
UTILITIES
(502) 867-8240 (office)
Contact Person: Frank Ambrose
Georgetown, KY 40324
894 East Main Street Ext
AT&T
TELEPHONE:
ROCKY CREEK LANE PAVEMENT
1
2
NOTES:
Special Note for Bridge Overlay Approach Pavement
GRANULAR EMBANKMENT in accordance with the
paved area will be measured and paid as
DGA Base needed for shoulders outside of
by the field engineer
Width varies and the location to be determined
4.00" CL2 Asph Base 1.00D PG64-22
4.00" CL2 Asph Base 1.00D PG64-22
8.00" DGA Base
1.25" CL2 Asph Surf 0.38D PG64-22
16.00" Base
1.25" Surface
Detail "A"
!
Varies
NORMAL SECTION
VARIES
Varies Varies
VARIES
Varies
Shld
Grade point
2’-0"2’-0"
Shld
8.0%8.0%
2 2
1 1
8.00" DGA Base
4.00" CL2 Asph Base 1.00D PG64-22
4.00" CL2 Asph Base 1.00D PG64-22
1.25" CL2 Asph Surf 0.38D PG64-22
Detail "A"
1
BEFORE YOU DIG
utility companies have facilities in the area. may be necessary for the contractor to contact the County Court Clerk to determine what excavation with the utility owners, including those whom do not subscribe to KY 811. It members of the KY 811 one-call Before-U-Dig (BUD) service. The contractor must coordinate contractor should be aware that owners of underground facilities are not required to be a minimum of two (2) and no more than ten (10) business days prior to excavation. The for information on the location of existing underground utilities. The call is to be placed The contractor is instructed to call 1-800-752-6007 to reach KY 811, the one-call system
8’-0" to 15’-3" 7’-6" to 15’-3"
EX. R/
W
2:1
5’
Detail "B"
Detail "B"
Non-ReinforcedGravity TypeRetaining Wall
3
3
excavation is incidental to concrete class B
Location to be determined by the field engineer and
BRIDGE TYPICAL SECTION
15’-3’’ 15’-3’’
30’-6’’9’’
32’-0’’
9’’
P/G
CL Bridge
2%2%
2’-0’’
8~CB12 Box Beams @ 4’-0" = 28’-0’’
2’-0’’
Co
nc. Sla
b5’’ Cla
ss "A
A"
and Sepia 035.Std. Dwg. BDP-005-05Railing System Type II. See5’
TYPICAL SECTIONS AND LEGEND
E-S
HE
ET
NA
ME:
R00200
TS
Micro
Statio
n v8.11.7.443
COUNTY OF ITEM NO. SHEET NO.
OHIO 2-10015 R2
ROCKY CREEK LANE (CR 1083) OVER
BRANCH OF SOUTH FORK PANTHER CREEKNTS
PREPARED BY
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME: ...\d014
7571\
Ty
pic
al.
dgn
12:09:56
AM
agille
y
1/4/2019
0’ 40’ 80’20’
elevation of CP #1 (437.26’)utilizing the KYCORS RTN Network and were adjusted by a closed differential level loop based on the Elevations were established by redundant GPS observations NAVD88 vertical datum, Geoid 12B BASIS OF ELEVATIONS
Coordinates, US Survey Feet. No project datum factor was calculated or used for this project.Feet utilizing the KYCORS RTN GPS Network on October 31, 2018. Coordinates shown are State PlaneGNSS receivers. On the NAD83 Kentucky State Plane Coordinate System, KY Single Zone, US Survey Coordinates for horizontal control were obtained by redundant GPS observations using Trimble R10 PROJECT COORDINATES
MAGAN ROAD
Ditch
Existing R
/W
Existing R/W
Existing R/W
Existin
g
R/
W
Existing R/W
Existin
g R/
W
Panther
Creek
Branch of South Fork
Panther
Creek
Branch of South Fork
Asphalt
CP #3
CP #1
CP #2
E 4608979.33
N 3747689.98
STA. 0+56.75
BEGIN PROJECT
E 4609083.94
N 3747795.30
STA. 2+24.56
END PROJECT
EAST (X)NORTH (Y)
COORDINATE CONTROL POINTS
POINT
ELEV. (Z)
DESCRIPTION
State Plane Coordinates
STATION OFFSET
0+54.67 165.46’ LT.
1+85.21 150.72’ RT.
5/8" REBAR & CAP
1
2
3
3747855.393 4608981.725 437.261
437.539
436.6554609087.055
4609212.0583747696.167
3747713.093 1+52.24 29.09’ RT.
BEGIN APPROACH PAVEMENT
STA. 0+92.00
END APPROACH PAVEMENT
STA. 2+02.73
17"
CM
P
I.E.=434.66
O.E.=433.42
(CR 1083)
ROCKY CREEK LANE
RUSSELL
RALPH & RUBY
CONNECT TO BRIDGE RAIL SYSTEM TYPE II
WITH 1-GUARDRAIL END TREATMENT TYPE 7
25 L.F. GUARDRAIL-STEEL W BEAM-S FACE A
LT. STA. 0+56.75 TO STA. 1+45.53 CONST.
CONNECT TO BRIDGE RAIL SYSTEM TYPE II
WITH 1-GUARDRAIL END TREATMENT TYPE 7
25 L.F. GUARDRAIL-STEEL W BEAM-S FACE A
RT. STA. 1+79.03 TO STA. 1+84.54 CONST.
C
C
0+00
2+33
2+33
4608922.60
3747691.
47
0+00.00
PO
B
4609007.83
3747689.24
0+85.26
PC
4609
087.
37
3747
803.
34
2+33.3
0
POE
PI
1+15.86
MONUMENT W/ALUM. CAP
MONUMENT W/ALUM. CAP
30’ R
50’ R
DIT
CH
e= NC
E= 9.42’
R= 45.00’
L= 53.74’
T= 30.60’
E= 4609038.42
N= 3747688.44
P.I. Sta= 1+15.86
DNDTEL JB
TEL JB
WM
WM
WM WM
4609
050.
41
3747
716.5
9
1+39.0
1
PT
WM8’-0"
7’-6"
EXISTING BRIDGE ID: 092C00097N
BRIDGE
EXISTING
REMOVE
BY OTHERS
TO BE RELOCATED
S 88°29’56" E
N 23°04’2
2"
E
CONNECT TO BRIDGE RAIL SYSTEM TYPE II
WITH 1-GUARDRAIL END TREATMENT TYPE 7
25 L.F. GUARDRAIL-STEEL W BEAM-S FACE A
RT. STA. 0+86.03 TO STA. 1+45.53 CONST.
CATHERINE AND MICHAEL E. RALPH
PLAN
E-S
HE
ET
NA
ME:
R00300
PL
Micro
Statio
n v8.11.7.443
COUNTY OF ITEM NO. SHEET NO.
OHIO 2-10015 R3
ROCKY CREEK LANE (CR 1083) OVER
BRANCH OF SOUTH FORK PANTHER CREEK
PREPARED BY
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME: c:\p
w_
workin
g\d014
7571\
Pla
n.dgn
11:15:16
AM
agille
y
1/4/2019
CONNECT TO BRIDGE RAIL SYSTEM TYPE II
WITH 1-GUARDRAIL END TREATMENT TYPE 7
25 L.F. GUARDRAIL-STEEL W BEAM-S FACE A
LT. STA. 1+79.03 TO STA. 2+24.56 CONST.
30.6 L.F. - 5’ FLAT BOTTOM DITCH
LT. STA. 1+15.84 TO STA. 1+61.36 CONST.
EXCAVATION IS INCIDENTAL
NON-REINFORCED ~ 7.0 CUYD CONCRETE CLASS B
RETAINING WALL GRAVITY TYPE
LT. STA. 1+14.53 TO STA. 1+51.72 CONST.
IP
410
412
414
416
418
420
422
424
426
428
430
432
434
436
438
440
442
444
446
448448
412
414
416
418
420
422
424
426
428
430
432
434
436
438
440
442
444
446
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40
410
412
414
416
418
420
422
424
426
428
430
432
434
436
438
440
442
444
446
448448
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40
436.8
436.8
436.7
436.8
436.8
436.8
437.1
437.0
431.
0
437.2
436.4
436.0
436.83
437.05
437.27
437.44
437.52
436.33
DATUM
COUNTY OF ITEM NO. SHEET NO.
OHIO 2-10015 R4
DATUM
ROCKY CREEK ROAD (CR 1083) OVER
BRANCH OF SOUTH FORK PANTHER CREEK
PROFILEPREPARED BY
E-S
HE
ET
NA
ME:
R00400
PF
Micro
Statio
n v8.11.7.443
C:\
PW
_W
OR
KIN
G\
D014
7571\
PR
OFIL
E.
DG
NFIL
E
NA
ME:
January
4, 2019
DA
TE P
LO
TT
ED:
agille
yU
SE
R:
0’ 40’ 80’20’
2’
4’
8’
0’
Road
Magan
ELEV 435.51
LOW BEAM
PROPOSED
(CR 1083)
ROCKY CREEK LANE
ELEV 435.19
LOW BEAM
EXISTING
STA. 0+56.75
BEGIN PROJECT
END APPROACH PAVEMENT
STA. 2+02.73
STA. 2+24.56
END PROJECT
BEGIN APPROACH PAVEMENT
STA. 0+92.00
PVI 0
+92.00
Ele
v 436.71
PVI 1+
45.53
Ele
v 437.33
PVI 1+
79.03
Ele
v 437.57
PVI 2
+02.73
Ele
v 436.16
1.16% -5.94%
0.72%
@ 0° S
KE
W
CO
MP
OSIT
E
DE
CK
BRID
GE
1-S
PA
N
CB 12
X48 P
PC
ST
A 1+
62.28
CO
NS
T.
and all appurtenances. Contractor shall final dress all slopes to maximum of 2:1.
structureexisting of removal complete the include shall full in payment sum Lump
abutments.timber (2) two and bridge pipe steel half connected mechanically 23’ (1) one of
consists structure existing The specifications. current the with accordance in of
disposed be shall and contractor the of property the remain shall
bridgeexisting the in material All specifications. the with accordance in
The existing 23’x32’ - one (1) span mechanically connected half steel pipe bridge shall be removed
BRIDGE REMOVAL NOTE
0’ 40’ 80’20’
MAGAN ROAD
Ditch
Existing R
/W
Existing R/W
Existing R/W
Existin
g
R/
W
Existing R/W
Existin
g R/
W
Panther
Creek
Branch of South Fork
Asphalt
CP #3
CP #1
E 4608979.33
N 3747689.98
STA. 0+56.75
BEGIN PROJECT
E 4609083.94
N 3747795.30
STA. 2+24.56
END PROJECT
17"
CM
P
(CR 1083)
ROCKY CREEK LANE
RUSSELL
RALPH & RUBY
0+00
2+33
2+33
TEL JB
TEL JB
WM
WM
WM WMWM
CATHERINE AND MICHAEL E. RALPH
TEMPORARY TRAFFIC BARRIER
LEGEND
TRAFFIC ONLY
FOR MAINTENANCE OF
LA
NE
SIN
GL
E
6’
10’-6"
BRIDGE CONSTRUCTION
MAGAN ROAD
Ditch
Existing R
/W
Existing R/W
Existing R/W
Existin
g
R/
WExisting R/W
Existin
g R/
W
Panther
Creek
Branch of South Fork
Asphalt
CP #3
CP #1
E 4608979.33
N 3747689.98
STA. 0+56.75
BEGIN PROJECT
E 4609083.94
N 3747795.30
STA. 2+24.56
END PROJECT
17"
CM
P
(CR 1083)
ROCKY CREEK LANE
RUSSELL
RALPH & RUBY
0+00
2+33
2+33
TEL JB
TEL JB
WM
WM
WM WMWM
CATHERINE AND MICHAEL E. RALPH
LA
NE
SIN
GL
E
IP
Asphalt
DIT
CH
CHANNELIZING DEVICES
12’-3"
PHASE 1 & 2 PHASE 3 & 4
CRASH CUSHION
SH
OU
LD
ER
TRAFFIC CONTROL PLAN
E-S
HE
ET
NA
ME:
R00300
PL
Micro
Statio
n v8.11.7.443
COUNTY OF ITEM NO. SHEET NO.
OHIO 2-10015 R5
ROCKY CREEK LANE (CR 1083) OVER
BRANCH OF SOUTH FORK PANTHER CREEK
PREPARED BY
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME: c:\p
w_
workin
g\d014
7571\
MO
T.dgn
11:29:35
AM
agille
y
1/4/2019
PHASE NOTES, DETAILS, AND TYPICAL SECTIONS.
SEE SHEET S6 FOR BRIDGE PARTIAL WIDTH CONSTRUCTION
NOTE:
IP
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.9.459
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S. Weber M. Vickers
C. Quinn M. Vickers
OHIO
CR1083 BRANCH OF S. FORK PANTHER CREEK
GENERAL NOTES
S1
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
3:10:31
PM
...\d014
7588\
Ge
neral
Notes.dgn
agille
y
1/4/2019
8th edition with interims.
the AASHTO specifications are to the AASHTO LRFD Bridge Design Specifications,
Construction including any current supplemental specifications. All references to
Kentucky Department of Highways Standard Specifications for Road and Bridge
Specifications: References to the specifications are to the current edition of the
This bridge is designed for a future wearing surface of 15 psf.
Design Load: This bridge is designed for KYHL-93 live load, (i.e. 1.25xAASHTO HL93 live load).
Specifications.
than the load and resistance factor design method as specified in the current AASHTO
Design Method: All reinforced concrete members are designed to be equivalent or greater
fy = 60000 psiFor Steel Reinforcement
f’c = 4000 psiFor Class "AA" Reinforced Concrete
f’c = 3500 psiFor Class "A" Reinforced Concrete
Materials Design Specifications:
Grade 60
Deformed and Plain Billet-Steel for Concrete Reinforcement,AASHTO M-31
Premolded Cork Filler, Type IIAASHTO M153
below shall govern the materials furnished.
Material Specifications: AASHTO Specifications or ASTM, current edition, as designated
Specifications.
conform to subsection 807.04.02 (Type II) of the Kentucky Department of Highways Standard
Preformed Cork Expansion Joint Material: Preformed Cork Expansion Joint Material shall
the plans and specifications.
the substructure below the caps. Prestressed beam concrete shall be in accordance with
portions of the substructure above the tops of caps. Class "A" concrete is to be used in
Concrete: Class "AA" Concrete is to be used throughout the superstructure and in the
Bill of Reinforcement shall be considered a stirrup for purposes of bend diameters.
811.10 of the Standard Specifications. Any reinforcing bars designated by suffix "s" in a
bars designated by suffix "e" in the plans shall be epoxy coated in accordance with section
unless otherwise shown. Spacing of bars is from center to center of bars. Any reinforcing
Reinforcement: Dimensions shown from the face of concrete to bars are to center of bars
the work for which no direct payment will be made.
engineer. The contractor shall furnish all plans, equipment and labor necessary to do
shall be imprinted in the concrete with 1 inch letters at a location designated by the
Construction Identification: The names of the Prime Contractor and the Sub-Contractor
specifications.
Beams shall be at the contract unit price per linear foot of beam, in accordance with the
Payment for Precast Concrete Beams: The basis of payment for the Prestressed Concrete
incidental to the unit price bid for Dry Cyclopean Stone Riprap.
Specifications 214 and 843. Payment for Geotextile Fabric, Type I, shall be considered
between the embankment and the slope protection in accordance with Standard
accordance with the plans and specifications. Geotextile Fabric, Type I shall be placed
Slope Protection: Slope Protection at abutments shall be dry cyclopean stone riprap in
labor, or anything else required to complete the structure.
removal of all or parts of existing structures, phase construction, incidental materials,
the work involved. This may include cofferdams, shoring, excavations, backfilling,
operations not otherwise specified, are to be included in the bid item most appropriate to
accordance with the plans and specifications. Material, labor, or construction
Completion of the Structure: The contractor is required to complete the structure in
contractor.
drawings reflecting these changes shall be submitted to the consultant through the
When any changes in the design plans are proposed by the fabricator or supplier, the shop
case by case basis.
paper copies, Construction Management Team reserves the right to require such copies on a
Team" are to be used for fabrication. While this process does not require the submission of
distributed, and only plans electronically stamped "Distributed by Construction Management
for distribution. Only plans submitted directly to the Construction Management Team will be
stamped by the designer and plans will be forwarded to the Construction Management Team
designer’s comments, files shall be returned to the designer. Each sheet will be electronically
submissions as needed and return them to the fabricator. Upon reconciliation of the
either 11" x 17" or 22" x 36" sheets. Designers will make review comments on these electronic
consultant for review. These submissions shall depict the shop plans, in .pdf format, as
Shop Drawings: Fabricators shall submit all required shop plans, by e-mail, to the design
activities that may involve utilities (overhead or underground).
prior to excavation of material or installation of guardrail or other construction
Utilities: The contractor shall be responsible for locating any and all existing utilities
shall be replaced at the contractor’s expense.
material. New material that is unsuitable because of variations in the existing structure
Verifying Field Conditions: The contractor shall field verify all dimensions before ordering
dimensions are horizontal dimensions.
Dimensions: Dimensions are for a normal temperature of 60 degrees fahrenheit. Layout
end of slab before the concrete is allowed to set.
Superstructure Slab: The superstructure slab shall be poured continuously from end to
measurement of payment shall be made.
shall be considered incidental to the unit price bid for concrete class ’AA’ and no separate
The cost of labor, materials, and incidental items for furnishing and installing Mastic Tape
manufacturer’s recommendations with the overlap running downhill.
Mastic Tape shall be spliced by taping a minimum of 6" and in accordance with the
Mastic Tape shall cover the joint continuously unless otherwise shown in the plans.
or approved equal.
Cadilloc by The UP Rubber Co. Inc.
Seal Wrap by Mar Mac Manufacturing Co. Inc.,
EZ-Wrap Rubber by Press-seal Casket Corporation,
Mastic Tape shall be either:
of the joint.
required by the tape manufacturer, shall be applied for a minimum width of 9" on each side
the joint surface shall be clean and free of dirt, debris, or deleterious material. Primer, if
Type I, II, or III. The joint is to be covered with 12" wide mastic tape. Prior to application,
Mastic Tape: Mastic Tape used to seal joints is to meet the requirements of ASTM C-877
when pouring the concrete deck slab or when taking "top of beam" elevations.
Temporary Supports: Temporary Supports or shoring will not be permitted under the beams
end of bridge.
Armored Edge: Fabricate armored edge to match cross slope and parabolic crown at each
of the Specifications.
Foundation Preparation: Foundation Preparation shall be in accordance with Section 603
but shall be included in the Lump Sum Bid for Foundation Preparation.
Contrary to the Specifications, Structural Granular Backfill will not be measured for payment
with Section 805 of the Specifications.
Structural Granular Backfill: Materials for Structural Granular Backfill shall be in accordance
of the specifications and of the type shown on the pile record sheet.
Pile Points: Provide pile points for all piles. Pile points shall be in accordance with Section 604
General Notes
notarized.
Contrary to the standard drawings for steel piling, mill test reports are not required to be
structure.
All test piles shall be accurately located so that they may be used in the finished
required.
Test piles shall be driven where designated on the plans to determine the length of pile
Piling: Piling shall be driven to practical refusal as defined on the pile record sheet.
width end bent construction.
temporary shoring, sheeting, steel traffic plates as needed to maintain traffic and allow partial
information provided within the plans and specifications. The contractor shall provide
use the minimum lap splice lengths or KYTC approved mechanical couplers in accordance with
a minimum of 2" cover to the nearest stirrup reinforcing bar. The contractor has the option to
joints on the endbents shall be located to provide minimum of 1’-0" cover from pile edges, and
extent of partial demolition of the existing bridge structure. The location of the construction
plans for phasing scheme. Endbents and deck exact partial widths shall be dependant on the
Partial Width Construction: Project requires phased partial width construction. Refer to MOT
if the actual quantity is different than this estimate.
contractor to verify this estimate and bid appropriately. No payment adjustments will be made
Concrete Coating: Concrete Coating is estimated at 1215 S.F. It is the responsibility of the
Beveled Edges: All exposed edges shall be beveled �", unless otherwise shown.
(CR 10
83)
RO
CK
Y
CR
EE
K
LA
NE
MA
GA
N
RD.
2:1 N
ormal
Detail
Toe of Slope
Line
Ground
2’-0"
2’-
0"
2’-
0"
0.72%
Ele
v 437.33
Ditch4
35
435
435
435
435
435
TE
L J
B
Datum Line424
426
428
430
432
434
436
438
440
442
2+00
1+00
WM
BRANCH OF SOUTH FORK PANTHER CREEK
1.16%
PVI 2
+02.73
Ele
v 436.16
PVI 1+
45.53
PVI 1+
79.03
-5.94%
4609
007.
8337
4768
9.24
0+85.
26PC
e= NC
E= 9.42’
R= 45.00’
L= 53.74’
T= 30.60’
E= 4609038.42
N= 3747688.44
P.I. Sta= 1+15.86
1+15.86
PC
4609050.41
3747716.59
1+39.01
PT
4609087.37
3747803.34
2+33.30
PO
E
Existing R/W
DITCH
Ele
v 437.57
PA
NT
HE
R
CR
EE
K
BR
AN
CH
OF S
OU
TH F
OR
K
DEAD END (Residents Only)
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.9.459
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S. Weber M. Vickers
C. Quinn M. Vickers
OHIO
CR1083
LAYOUT
S2
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
3:13:31
PM
...\p
w_
workin
g\d014
7588\
Lay
out.dgn
agille
y
1/4/2019
ELEVATION
PLAN
! Magan Rd.
Sta. 1+79.03
End Bridge
30’-6" Bridge Roadway Width - 0° Skew
Live Load 1.25 x HL-93 (KY HL-93)
32’-0" Single Span CB12 PPC Box Beam
! Bridge
33’-6" Out to Out
32’-0" ! Brg. to ! Brg.
(Superstructure Not Shown)
Type 1
Geotextile Fabric
Stone Rip-Rap over
2’-0" Thick Cyclopean
(Remove)
Abutment
Existing
Elev. 435.70
Low Bridge Seat
Elev. 434.70
Pile Cutoff
2
11
2Elev. 435.47
Low Bridge Seat
Elev. 434.47
Pile Cutoff
Stone Rip-Rap (Typ.)
Limits of Cyclopean
Sta. 1+45.53
Begin Bridge
Local Tangent
Relocate
433.97
Elev.
Berm
434.20
Elev.
Berm
E=4609053.26
N=3747723.28
Sta. 1+46.28
! Brg. E.B.#1
E=4609065.80
N=3747752.72
Sta. 1+78.28
! Brg. E.B.#2
Wall
Gravity
Ex. Ground Line
End Bent #1 End Bent #2
3’-0" Berm (Typ.)
Width (Typ.)3’-0" Berm
(Fix)(Fix)
2%2%
1’-0" 1’-0" 1’-0" 1’-0" 1’-0" 1’-0"
�"
.0
033’
�"
.0
133’
�"
.0
133’
�"
.0
30
0’
�"
.0
033’
-2.0% -2.0%}{
Concrete Surface Profile Grade
6’-0" Vertical Curve
PARABOLIC CROWN
! Bridge
BRANCH OF SOUTH FORK PANTHER CREEK
TYPICAL SECTION
of bridge to prevent damage to tape.
shall be looped as shown at expansion ends
between beam ends and abutment. Tape
mastic tape to water-proof the joint
Note: Contractor shall provide 12" wide
END OF BEAM DETAIL
To Beam
Measured Parallel
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.7.443
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S. Weber M. Vickers
C. Quinn M. Vickers
OHIO
CR1083
TYPICAL SECTION
S3
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
2:23:51
AM
...\d014
7588\
Ty
pic
al
Sectio
n.dgn
agille
y
1/4/2019
#5 Bars @ 12" Max. Spacing
6’-0" Parabolic Crown
32’-0"
30’-6"9" 9"
15’-3"15’-3"
P/G
! Bridge
"AA" Conc.5" Slab Class
Clr.2�"
Max. Spacing#5 Bar @ 12"
Note: All Slab Reinf. to be Epoxy Coated
Rustication Groove
8~CB12 Box Beams @ 4’-0" = 32’-0"
End of Bridge
Mastic Tape
of Abut.
Back Face
! Bearing
Armored Edge
9" 9"
1�" +/-
Loop
and Sepia 035Std. Dwg. BDP-005-05Railing System Type II. See
Longitudinal Deck Bar.a Minimum of 3" Clear Cover to the NearestLongitudinal Construction Joint Shall ProvideLap Splice Length for #5 Deck Bars is 2’-5". (or Mechanically Coupled). Mininum Required#5 Transverse Deck Bars to be Lap SplicedPhased Partial Width Construction Requires
No.
Pile
Elevation
Cut-off
Pile
In Place
Length
Pile
As Driven
Elevation
Point of Pile
Load
Axial
Design
PILE RECORD FOR POINT BEARING PILES
FEET FEET FEET TONS
1
2
3
4
5
6
7
8
9
10
Definitions of Terms
Field Data
calculations for Factored LRFD Loadings.
practical refusal.
CALCULATED FIELD BEARING: Contrary to Section 604.03.07 of the Standard Specifications,
in place bearing values are not required for piles bearing on rock when driven to
DESIGN AXIAL LOAD: Load carried by each pile as estimated from structural design
structure.
POINT OF PILE ELEVATION AS DRIVEN: Actual point of pile elevation in the finished
structure.
PILE LENGTH IN PLACE: Actual pile length below the Pile Cut-Off Elevation in the finished
PILE CUT-OFF ELEVATION: Elevation of the top of pile in the finished structure.
Length in Place and Point of Pile Elevation as Driven.
For each pile, the Project Engineer shall record the following on this sheet: Pile
required to keep and submit.
This pile record does not replace other pile records the Project Engineer is
Submit this record to:
DRIVING CRITERIA: Drive point bearing piles to practical refusal.
Frankfort, KY 40622
200 Mero Street
3rd Floor East
Director, Division of Structural Design
Kentucky Transportation Cabinet
3’ -6�
" 4 Spa.
@ 8’-
0"
= 32’ -0"
3’ -6�
"
3’ -6�
" 4 Spa.
@ 8’-
0"
= 32’ -0"
3’ -6�
"
90°0’0"
PILE LAYOUT
103
103
103
103
103
103
103
103
103
103
434.47
434.70
39’ -1"
! Brg. E.B.#1
! Brg. E.B.#2
Ahead
! Bridge
Local Tangent
434.47
434.47
434.47
434.47
434.70
434.70
434.70
434.70
Use HP 12x53 in accordance with BPS-003, c.e.
Pile #1
Pile #2
Pile #3
Pile #4 Pile #9
Pile #10
Pile #8
Pile #6
Pile #7
pile driving procedures.by the Engineer will be subject to satisfactory field performance of the prior to the installation of the first pile. Approval of the pile driving systemContractor shall submit the proposed pile driving system to the Engineerwithout encountering excessive blow counts or damage to the piles. The 27 foot-kips will be required to drive 12x53 steel H-piles to practical refusalA diesel pile driving hammer with a rated energy between 15 foot-kips and
groundwater will be encountered at foundation locations within the floodplain.required to facilitate foundation construction. it should be anticipated that Temporary shoring, sheeting, cofferdams and/or a dewatering method may be
performed in accordance with applicable federal, state, and local guidelines.safety to people working in or around the excavations. Bracing should be Foundation excavations should be properly braced/shored to provide adequate
Pile #5 (Test Pile)
Driving Criteria and Pile Notes
Drive additional production and test piles if directed by the Engineer.specified for practical refusal is required to further advance the pile. Engineer will determine if more blows than the average driving resistance boulder before the pile is advanced to the depth anticipated, the encountered because of dense strata or an obstruction, such as a visibly yields or becomes damaged during driving. If hard driving is subsurface data sheet(s). Immediately cease driving operations if the pile resistances specifed above and to depths determined by test pile(s) and penetration of �" or less. Advance the production piling to the driving is obtained after the pile is struck an additional 10 blows with total penetration becomes �" or less for 10 consecutive blows, practical refusal For this project minimum blow requirements are reached after total
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.9.459
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S. Weber M. Vickers
C. Quinn M. Vickers
OHIO
CR1083 BRANCH OF S. FORK PANTHER CREEK
PILE RECORD
S4
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
10:24:03 P
M...\d014
7588\
Pile
Record.dgn
agille
y
1/7/2019
and Bridge Construction, current edition.accordance with Section 604 of the Kentucky Standard Specifications for Roadmay be encountered is recommended. Installation of pile points should be in of reinforced pile points capable of penetrating boulders and hard layers which used on end bearing piles to allow for embedment into the top of bedrock. UseThe Kentucky Transportation Cabinet recommends that protective pile points be
Construction.Kentucky Department of Highway Standard Specifications for Road and BridgeBridge Design Specifications, and Section 604 of the current edition of the The installation of the pile foundations should conform to current AASHTO LRFD
"A" 2’-0"
"B"~A1 @ "C" = "D"
A2 A3
6"
1’-6"
3’-
0"
"WV"
"WX"
A5
A6
about this !
reinforcement symetrical
All dimension and
! Bridge
A5 or A6
Trim A4-A6 bars as necessary.
NOTE:
3’-
0"
! Brg. & ! Cap
="F" (Typ.)
"E"~A1 @ 12"
PLAN
ELEVATION
5~A2 as shown
1’-6"
3’-0"
1"
4~A2 Eq. Spa.
B
A
A
B
3’-
0"
5~A2 as shown
3’-
0"
1’-6"
3’-0"
1"
4~A2 Eq. Spa.
Em
b.
Min.
1’-6"
9"
SECTION B-B
SECTION A-A
! Brg. & ! Cap
! Brg. & ! Cap
3" cl.
A6
= "H"
"G"~A4 @ 12"
3" cl.
3" cl.
90°
Varie
s
A4
A4
6"
+
SD
H
6"
+
SD
H(If necessary)
Field Bend
"PE" "PE"
*WL
*16’-0�" (32’ bridge width)
*12’-0�" (24’ bridge width)
*8’-0�" (16’ bridge width)
rolled beam superstructure
*Adjust 9" as necessary for
"L"
joint material (Typ.)
�" expansion
(Ty
p.)
2’-
0"
*"WL"
*"WU"
16
A B C D E F G
3�" 4 2’-3" 7 6’-0" 3
H
2’-0"
WL
3’-6"
WU WV WXL
23’-1"
J
MARK TYPE NO. SIZE LENGTH
A1e 22 5 11- 0
A2e Str. 9 8 22- 9
14s
A3e Str. 4 5 22- 9
A1e 24 5 11- 0
A2e Str. 9 8 25- 5
14s
A3e Str. 4 5 25- 5
A1e 29 5 11- 0
A2e Str. 9 8 30- 5
14s
A3e Str. 4 5 30- 5
WIDTH
BRIDGE
0
24
32
2�" 3 1’-2" 6 5’-0" 5 4’-0"
4�" 4 2’-0" 7 6’-0" 7 6’-0"
7"
8"
4’-10"
7’-4" 3’-3" 4’-1" 2’-1"
25’-9"
30’-9"
0
H1 92
H2
H3 107
87
SIZE TONS
97
122
99
133
PILE LOAD
9" 0
0
3�" 4 2’-3" 7 6’-0" 3 2’-0" 3’-6"31’-1"2 09" 0
4’-10"
7’-4"
3’-6"
4’-10"
7’-4"
3’-3" 4’-1" 2’-1"
00
3’-3" 4’-1" 2’-1"
00
00
33’-9"
38’-9"
39’-1"
41’-9"
46’-9"
2
3
4
3
4
2
3
4
5 4’-0"
7 6’-0"
5 4’-0"
7 6’-0"
3 2’-0"
6 5’-0"
7 6’-0"
7 6’-0"
6 5’-0"
7 6’-0"
3 1’-8"2�" 10"
4�" 4 2’-0"8"
3�" 4 2’-3"9"
4�" 4 2’-0"8"
4�" 4 2’-0"8"
16’-0" BRIDGE WIDTH
MARK TYPE NO. SIZE LENGTH
A1e 29 5 11- 0
A2e Str. 9 8 30- 9
14s
A3e Str. 4 5 30- 9
A1e 30 5 11- 0
A2e Str. 9 8 33- 5
14s
A3e Str. 4 5 33- 5
A1e 36 5 11- 0
A2e Str. 9 8 38- 5
14s
A3e Str. 4 5 38- 5
24’-0" BRIDGE WIDTH
MARK TYPE NO. SIZE LENGTH
A1e 36 5 11- 0
A2e* Str. 9* 8*
14s
Str.
A1e 38 5 11- 0
A2e Str. 9 8 41- 5
14s
A3e Str. 4 5 41- 5
A1e 43 5 11- 0
A2e Str. 9 8 46- 5
14s
A3e Str. 4 5 46- 5
32’-0" BRIDGE WIDTH
DIMENSIONS
A4e Str. 28 5
A5e Str. 16 5 7- 0
A6e Str. 4 6 7- 5
5-11
A4e Str. 20 5
A5e Str. 12 5 4- 6
A6e Str. 4 6 4- 6
4- 8
A4e Str. 12 5
A5e Str. 8 5 3- 2
A6e Str. 4 6 3- 2
4- 0
MARK TYPE NO. SIZE LENGTH
CAP BILL OF REINFORCEMENT
REINFORCEMENT
WING BILL OF
QUANTITIES
CONCRETE (C.Y.) STEEL (LBS.)
H1
H2
H3
H1
H2
H3
H1
H2
H3
2~A3 e.f. @ eq. spa.
2~A3 e.f. @ eq. spa.
(e.f.)
@ e
q. spa.
"J"~
A5
3’-6"
4’-10"
3’-6"
4’-10"
3’-6"
4’-10"
A1
A1
+(haunch+slab) [if applicable]
SDH = Beam+Pad Height
SUPERSTRUCTURE HEIGHT
12" SDH 27"
27" SDH 35"
35" SDH 50"
No. of Piles @ "PS" = "PL"
"L/2"
103
109
End Bent
Back Face of
9.8
12.2
16.8
12.4
14.8
19.4
15.1
17.5
22.1
1175
1527
1297
1469
1833
1787
2139
CAP BILL OF REINFORCEMENT
3
4
4
PS PL
8’-0"
PE
3’-6�" 16’-0"
2’-4�" 7’-0" 21’-0"
3’-4�" 8’-0" 24’-0"
5
5
4
6
6
5
3’-6�" 8’-0" 24’-0"
28’-0"7’-0"2’-10�"
3’-4�" 8’-0" 32’-0"
3’-6�" 8’-0" 32’-0"
3’-4�" 7’-0" 35’-0"
40’-0"8’-0"3’-4�"
PILES
NO.
(typ. each wing).are set and tensioning rods are tightenedbox beams. Wings shall be poured after beamsMandatory Construction joint for side by side
lap
6"
2’-
7"
2’-8"
A1 Bar
~Size #5~
seats with rolled steel beams to maintain proper roadway slope.
Slope cap as necessary with side by side box beams and step cap
NOTE:
(Berm)
2:1
SECTION THRU END BENT
3’-0"
(Showing berm and fill slope)
Min.
1’-0"
before driving piles.
of cap elevation
Fill to bottom
Geotextile Fabric Type I
Cyclopean Stone Rip Rap with
(Typ.)
2’-
0"
A3e** 4** 5**
38- 9*
38- 9**
991
1604***
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.9.459
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S. Weber M. Vickers
C. Quinn M. Vickers
OHIO
CR1083 BRANCH OF S. FORK PANTHER CREEK
PILE END BENTS 1 & 2
S5
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
2:20:13
AM
c:\p
w_
workin
g\d014
7588\.dgn.dgn
agille
y
1/4/2019
use of KYTC approved mechanical couplers.
cover splice lengths required for partial width construction in lieu of the optional
quantities for project have an additional quantity of steel reinforcment included to
***Steel quantity shown here is for single end bent full width constuction. Bid tab
in the contractor’s bid.
for A3e bars shall be 2’-5", accounted for on shop drawings, and included
use of KYTC approved mechanical couplers). The minimum lap splice length
lengths adjusted accordingly to account for lap splices (or the optional
width construction is required for project. Bar counts shall be doubled and
**A3e bar counts and length shown here assume full width construction. Partial
in the contractor’s bid.
for A2e bars shall be 4’-9", accounted for on shop drawings, and included
use of KYTC approved mechanical couplers). The minimum lap splice length
lengths adjusted accordingly to account for lap splices (or the optional
width construction is required for project. Bar counts shall be doubled and
*A2e bar counts and length shown here assume full width construction. Partial
PARTIAL WIDTH CONSTRUCTION STEEL REINFORCEMENT NOTES:
damaged piling.
encountering excessive blow counts or damaging the pile. Contractor shall be responsible for all
10) Contractor shall provide a hammer capable of driving the piling to refusal or capacity without
is required in all circumstances.
must be driven to 10’ below stream bed or to refusal on bedrock. A minimum pile length of 10’
9) Piles must be driven 10’ into existing ground or to refusal on bedrock. Piles at wet crossings
8) Pile load given is Factored Strength Load.
(Pile Load/0.4) using the Gates Method.
7) Piles driven to rock must be driven to Refusal. Friction Piles must be driven to
6) Piles may be HP12x53 or 16" Steel Pipes with �" wall thickness.
H3 - CB33, B42, CB42 or rolled steel beams up to 36" nominal depth.
H2 - CB21, B27, CB27, B33 or rolled steel beams up to 24" nominal depth.
H1 - B12, CB12, B17, CB17, B21 or rolled steel beams up to 16" nominal depth.
steel and concrete beams as shown in the current standards:
5) End Bents are designed for the maximum span of the following
4) Maintain 2" clear cover to reinforcement unless otherwise noted.
3) Rebar to be epoxy coated A615, Grade 60.
2) Concrete to be Class "A", 3500 psi.
1) Conform to KYTC, Standard Specifications, Current Edition.
NOTES:
31’-2�"
2%
P/G
CL Bridge
2%2%
32’-0"
30’-6"9"
15’-3" 15’-3"
9"
2’-0"8~CB12 Box Beams @ 4’-0" = 28’-0"
2’-0"
12’-3"
2’-3"
9"
31’-2�"
1’-7�"3’-8�"18’-5�"7’-5"
1’-7�"
12’-3"2’-3"
9"
16’-0"
1’-7�"3’-8�"18’-5�"7’-5"
1’-7�"
2%
12’-3"2’-3"
9"
16’-0"
C
BridgeL Existing
C
BridgeL Existing
C
BridgeL Existing
C
BridgeL Existing
C
BridgeL Existing
and Sepia 035See Std. Dwg. BDP-005-05 Railing System Type II.
E-S
HE
ET
NA
ME:
Micro
Statio
n v8.11.7.443
DRAWING NO.
SHEET NO.
Commonwealth of Kentucky
DEPARTMENT OF HIGHWAYSCOUNTY
ROUTE CROSSING
PREPARED BY
DETAILED BY:
DESIGNED BY:
DATE: CHECKED BY
REVISION DATE
2-10015
S.Weber M. Vickers
S.Weber M. Vickers
OHIO
CR 1083 BRANCH OF S. FORK PANTHER CR.
M.O.T
S6
27867
1/19
ITEM NUMBER
DA
TE P
LO
TT
ED:
US
ER:
FIL
E
NA
ME:
2:25:23
AM
...\092
C00097
N_
Ty
pic
al
MO
T.dgn
agille
y
1/4/2019
EXISTING TYPICAL SECTION
NOTE: FIELD VERIFY EXISTING DIMENSION
PHASE 1
PHASE 2
PHASE 3
(SINGLE LANE)
TRAFFIC FLOW
2. DEMOLISH REMAINING EXISTING BRIDGE
1. SHIFT TRAFFIC TO PROPOSED BRIDGE. (ONE LANE)
PHASE 4
(SINGLE LANE)
TRAFFIC FLOW
2. REMOVE TEMP BARRIER AND OPEN BRIDGE TO TRAFFIC
1. CONSTRUCT REMAINING PORTION OF BRIDGE.
37’-7�"
(SINGLE LANE)
TRAFFIC FLOW
19’-6" MIN.
6’-0"
(SHOULDER)
10’-6" MIN.2’-3"
9"
(SINGLE LANE)
TRAFFIC FLOW
19’-6" MIN.
6’-0"
(SHOULDER)
10’-6" MIN.2’-3"
9"
INITIATE AT THE JUNCTURE OF TWO EXISTING PIPE BEAMS.
4. REMOVE HATCHED AREA. CARE SHALL BE TAKEN AND REMOVAL SHALL
6’ SHOULDER ACROSS.
3. ADD DGA TO RIGHT SIDE AS NEEDED TO MAINTAIN 10’-6" MIN ROADWAY AND
2. INSTALL WALL TYPE 9T BARRIER.
INCIDENTAL TO MAINTENANCE OF TRAFFIC
1. BRACE EXISTING STRUCTURE THAT IS NOT BEING REMOVED. BRACING TO BE
AND CAP STEEL) OR UTILIZE KYTC APPROVED MECHANICAL COUPLERS.
5. CONTRACTOR HAS THE OPTION TO USE THE MINIMUM LAP SPLICE LENGTHS (BEND
TRAFFIC).
PLATES AS NEEDED TO MAINTAIN TRAFFIC (INCIDENTAL TO MAINTENANCE OF
4. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING/SHEETING/STEEL TRAFFIC
AND A MINIMUM OF 2" COVER TO THE NEAREST STIRRUP REINFORCING BAR.
LOCATED TO PROVIDE MINIMUM OF 1’-0" COVER FROM THE NEAREST PILE EDGE,
3. CONSTRUCTION JOINTS FOR PARTIAL WIDTHS OF END BENTS 1 & 2 SHALL BE
EXISTING ALIGNMENT PER PLANS.)
2. CONSTRUCT 16’ (4 BOX BEAM WIDTHS) OF PROPOSED BRIDGE. (SHIFTED FROM
1. SHIFT TRAFFIC TO EXISTING ROADWAY. (ONE LANE)