1.0 GENERAL 1.1 Purpose of the Installation Guide ...................................................................................................... 2 1.2 Customer’s Responsibility ................................................................................................................ 22.0 SAFE ROOF INSTALLATION 2.1 Erector’s Responsibility .................................................................................................................... 3 2.2 OSHA ................................................................................................................................................ 3 2.3 Walking & Working on Roof Panels .................................................................................................. 3 2.4 Handling Roof Materials in Strong Winds ......................................................................................... 43.0 CHECKING THE STRUCTURE 3.1 Completed and Braced ..................................................................................................................... 5 3.2 Lateral Stability ................................................................................................................................. 5 3.3 Alignment .......................................................................................................................................... 54.0 RECEIVING & HANDLING ROOF MATERIALS 4.1 Material Inventory ............................................................................................................................. 6 4.2 Equipment for Unloading and Lifting ................................................................................................. 6 4.3 Lifting Roof Panel Bundles ............................................................................................................... 6 4.4 Field Storage of Roof Materials ........................................................................................................ 7 4.5 Handling Individual Roof Panels ....................................................................................................... 85.0 ROOF INSTALLATION BASICS 5.1 Proper Tools ..................................................................................................................................... 9 5.2 Equipment List .................................................................................................................................. 9 5.3 Sealants ............................................................................................................................................ 9 5.4 Fasteners .......................................................................................................................................... 10 5.5 Field Cutting Panels and Flashing .................................................................................................... 116.0 ROOF PANEL LAYOUT 6.1 Sheeting Direction and Modularity .................................................................................................... 12 6.2 Layout & Checking for Coverage ...................................................................................................... 12 6.3 Appearance Considerations .............................................................................................................. 127.0 INSPECTION OF ROOF ASSEMBLY DURING INSTALLATION 7.1 Importance of Inspection .................................................................................................................. 13 7.2 Inspection List ................................................................................................................................... 138.0 STANDARD PARTS 8.1 General ............................................................................................................................................. 16 8.2 Standard Parts Details ...................................................................................................................... 179.0 ROOF INSTALLATION DETAILS 9.1 General ............................................................................................................................................. 25 9.2 Preparation for Roof Panel Installation ............................................................................................. 26 9.3 Roof Panel Installation ...................................................................................................................... 32 9.4 End Dam Installation ......................................................................................................................... 55 9.5 Termination Panel Installation ........................................................................................................... 63 9.6 Rake Trim Installation ....................................................................................................................... 73 9.7 Rake Transition Installation ............................................................................................................... 79 9.8 Ridge Cover Installation .................................................................................................................... 83 9.9 High Eave Transition Installation ...................................................................................................... 89 9.10 Eave Gutter Installation .................................................................................................................. 93 9.11 Hip and Valley Installation ............................................................................................................... 97
PageDwg: Date: February 2012
2
ET1-1-R0
1.0 GENERAL
1.1 Purpose of the Installation Guide
This installation guide is provided to Allsouth Pre-Engineered Components (APEC) customers and their erectors as the recommended procedure for the correct assembly of the APEC Standing Seam Roof System.
This guide is intended to be used in conjunction with the project’s erection drawings to help plan and orga-nize the installation of the APEC Standing Seam Roof System. The erection drawings identify the applicable roof conditions and govern specific part arrangements. The instructions will help you identify parts, establish the installation sequence, demonstrate correct assem-bly, and point out any areas or procedures requiring
special emphasis or attention. This installation guide applies to the standard APEC Standing Seam Roof System. Custom roof conditions, including custom details and instructions, will be covered by the erection drawings. In case of conflict between this installation guide and the erection drawings, the erection drawings will have precedence.
1.2 Customer’s ResponsibilityThe customer is responsible for proper installation of the roof in accordance with the erection drawings and this installation guide, and in accordance with good engineering and construction practices.
The customer must take the responsibility for selecting a competent erector, insist that the work be performed by qualified and experienced standing seam metal roof installers, insist that the erector take time to study and understand this guide, then ensure that the erector correctly follows the guide’s instructions.
APEC does not guarantee and is not liable for the quality of erection. APEC is not responsible for building defects that may be attributed to improper erection or the negli-gence of other parties.
Clarification concerning the APEC roof installation should be directed to the APEC Customer Service Manager.
Contact the APEC office:
Allsouth Pre-Engineered Components985 Technology Drive
Dothan, AL 36303Phone 334-699-8394
Fax 334-699-8395
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
3
ET1-1-R0
2.0 SAFE ROOF INSTALLATION
2.1 Erector’s ResponsibilityThe erector of the roof system is responsible for the safe execution of this installation guide. These instruc-tions are intended to describe the sequence and proper placement of parts. They are not intended to prescribe comprehensive safety procedures.
If the erector cannot safely assemble the roof in accor-dance with these instructions, it is the responsibility of the erector to stop the work and contact APEC to determine alternate assembly procedures.
2.2 OSHAThe Occupational Safety and Health Act (OSHA) has promulgated many regulations applicable to the installation of this or any other roof system. These regulations, identified as Part 1926, Safety and Health Regulations for Construction, are available from any government bookstore. The objective of the OSHA standards is to protect the worker from injury or illness. These OSHA regulations should be recognized as job site requirements and be fully complied with.
Failure to do so may result in substantial fines in the event of an OSHA inspection. Safe installation practices may be further defined and made mandatory by state or local ordinances.
Maintaining good housekeeping on the jobsite is recog-nized as being important to both OSHA compliance and to successful job completion.
2.3 Walking & Working on Roof PanelsDo not walk on the last installed panel run, as the un-secured edge could collapse under a person’s weight. When installing clips or making endlap connections, etc., stand where the roof structural will support your weight.
An approved and safe walking platform should be used in high traffic areas to prevent the roof panel from being deformed, scratched, or scuffed.
A. PLACING PANELS ON THE STRUCTUREDo not place bundles of panels on the roof structure without first verifying the structure will safely support the concentrated weight of the panels and the weight of the installation crew. Some roof structures may not be designed to support the weight of a full panel bundle without additional structure support.
B. WALKING ON ROOF PANELSDo not use a roof panel as a working platform. An unsecured panel could collapse under the weight of a person standing between purlins or at the panel end.
Assembled Sidelap (Typ.)
Leading Roof Panel
Leading Edge
CORRECTStep ONLY on secured roof panels.
CAUTIONDO NOT step on leading (unsecured) roof panel.
Leading Roof Panel
Leading EdgeAssembled Sidelap (Typ.)
Assembled Sidelap (Typ.)
Leading Roof Panel
Leading Edge
CORRECTStep ONLY on secured roof panels.
CAUTIONDO NOT step on leading (unsecured) roof panel.
Leading Roof Panel
Leading EdgeAssembled Sidelap (Typ.)
TS-324™ Roof System Installation Guide
F_TS0_000R00BRS
PageDwg: Date: February 2012
4
ET1-1-R0
TS-324™ Roof System Installation Guide2.0 SAFE ROOF INSTALLATION
2.3 Walking & Working on Roof Panels (Continued)C. SAFETY EQUIPMENTThe use of safety equipment for the roof panel installa-tion is recommended at all times during the installation process. However, when using lanyards, ensure that the clasp, belt hooks and wire cables are covered in such a manner that they will not scratch the panel surface if accidentally dragged along the panel.
D. CREW SIZEThe length of the individual roof panels should be considered when determining the crew size. It is rec-ommended that under normal conditions, there be one person for every ten feet of panel length, plus one.
E. PANEL OVERHANGDo not stand on the end of unsupported (cantile-vered) panels at the eave or ridge. Standing on the cantilever portion may result in panel collapse.
F. POINT LOADSWhen properly supported by the structurals, panels are designed to support uniform loads, which are evenly distributed over the panel surfaces. Point loads that occur in small or concentrated areas, such as heavy equipment, ladders or platform feet, may cause panel deformation or even panel collapse.
G. SLICK SURFACESPanel surfaces and structural steel surfaces are hard, smooth, and nonabsorbent, which causes these sur-faces to be very slick when wet or covered with snow or ice. Even blowing sand or heavy dust can make these surfaces difficult to walk on without slipping.Unpainted panel surfaces are often coated with oil to
accommodate the panel-fabrication process. Although designed to wash away or evaporate during normal weather, the oil on new panels can be extremely slick, especially during periods of light rain or dew.
Caution must be exercised to prevent slipping and falling onto the roof surface or even sliding off the roof. Non-slip footwear is a necessity and non-slip working platforms are recommended.
H. ELECTRICAL CONDUCTANCEMetal panels are excellent electrical conductors. A common cause of injury is the contact of metal panels with power lines during handling and installation. The location of all power lines must be noted and, if possible, flagged. The installation process must be routed to avoid accidental contact with all power lines and high voltage services and equipment. All tools and power cords must be properly insulated and grounded; the use of approved ground fault circuit breakers is recommended.
I. FALSE SECURITY OF INSULATIONBlanket and board insulation blocks the installer’s view of the ground below the roof. Serious injury can occur when the installer gets a false sense of security because he cannot see the ground and steps through the insula-tion.
J. SHARP EDGESSome edges of panels and flashing are razor sharp and can cause severe cuts if proper protective hand gear is not worn. Be careful not to injure others while moving panels and flashing.
2.4. Handling Roof Materials in Strong WindsDo not attempt to move panels in strong winds. Wind pressure can easily cause a man to lose balance and fall. Strong wind uplift on a panel can lift the weight of the man carrying the panel.
Loose, wind-borne panels are very dangerous and can cause severe injury and damage.
Secure stacks of panels with banding or tie-downs, so wind will not blow the panels off the roof. Clamp indi-vidual unsecured panels to the roof structurals. Clamp or block panel bundles and accessory crates to prevent them from sliding down the roof slope.
PageDwg: Date: February 2012
5
ET1-1-R0
TS-324™ Roof System Installation Guide3.0 CHECKING THE STRUCTURE
3.1 Completed and BracedBefore placing materials and workers on the roof struc-ture to start roof installation, it must be confirmed that the structure is designed to accommodate the material and erection loads as well as the appropriate live loads and wind uplift loads.
It also must be determined that the structure is complete and structurally sound with all structural connections and bracing in place and secure.
3.2 Lateral StabilityThe sliding clip method of attaching the roof panels to the roof structurals provides only limited lateral stability and diaphragm bracing to the roof structurals.
Before placing materials on the roof and starting the roof installation, confirm that the necessary roof bracing and sag angles, strapping or bridging for purlin stability is in place and secured.
3.3 AlignmentPrior to installation, roof structurals should be checked for overall dimensions and evenness of plane. The roof structurals should also be checked to verify the roof system could be installed without interference. Also, roof structurals nearest the panel endlaps, ridge or high eave should be checked for correct location to properly accommodate the roof components.
A. TOLERANCESTo ensure the roof system’s correct fit-up and designed weather tightness, the structure must be aligned within the following tolerances:
Out of Square — The roof system can only accom-modate 1/4” of sawtooth of the roof panel ends at the eave, ridge and panel splices. This means the allow-able out of square of the rake line relative to the eave line and ridge line is 1/4” for each 40’ of rake run.
Structure Width and Eave Straightness — The roof system is designed to accommodate ±2” of overall structure width error, or ±1” of eave straightness error at each eave.
To ensure that the accumulation of the structure width error and eave straightness error does not exceed the roof system’s tolerance, the structure width should be measured from eave line to eave line at each rake, at the first frame line from each rake and at each point where there is a significant error or change in eave straightness (this usually occurs at a frame line or at a wind column).
Structure Length and Rake Straightness — The roof system is designed to accommodate ±2” of overall structure length error, or ±1” of rake straightness error at each rake.
To ensure that the accumulation of structure length error and rake straightness error does not exceed the roof system’s tolerance, the structure length should be measured from rake line to rake line at each eave, at the ridge and at each point where there is a significant error or change in rake straightness (this usually occurs at an end rafter splice).
B. MEASURINGStructure length and width may be measured with a steel measuring tape from the face of the eave or rake member to the face of the opposite eave or rake member. The measuring tape must be parallel to the relative eave or rake line and must be stretched taut.
Eave and rake straightness may be determined by mea-suring deviations from a string line, which is stretched taut along the eave or rake line.
C. AESTHETIC ACCEPTANCEAlthough these structure alignment tolerances will al-low for reasonable roof component fit-up and ease of installation, the extremes of these tolerances may be aesthetically objectionable and should be confirmed with the customer before starting the roof installation.
D. CORRECTIONSAny structure alignment error, which exceeds the above stated tolerances, must be corrected before roof installa-tion can begin. If it is decided that the structure alignment errors cannot be corrected, alternate roof details may need to be developed. The alternate details may require additional materials, modified parts (with additional cost, fabrication and delivery time) and additional installation time. APEC cannot ensure the performance of such alternate details.
PageDwg: Date: February 2012
6
ET1-1-R0
TS-324™ Roof System Installation Guide
Panel
Spreader
Bundle Fork Lift
Fork Blades
Web Slings
Panel Bundle
5’ Minimum
3 Equal Spaces, Panel length 35' or less
Limited to 25'
4 Equal Spaces, Panel length more than 35'
Panel
Spreader
Bundle Fork Lift
Fork Blades
Web Slings
Panel Bundle
5’ Minimum
3 Equal Spaces, Panel length 35' or less
Limited to 25'
4 Equal Spaces, Panel length more than 35'
4.0 RECEIVING & HANDLING ROOF MATERIALS
Your material is carefully inspected and crated before leaving the plant and accepted by the transportation company as being complete and in satisfactory con-dition. It is the carrier’s responsibility to deliver the shipment intact. It is the consignee’s responsibility to inspect the shipment for damages and shortages when it is delivered.
Conducting a material inventory at the time of delivery is essential. By conducting the materials inventory, the erector is able to identify any material shortage or damage and avoid stopping installation later because of such shortage or damage.
It is imperative that any shortages or damage of the de-livered materials be noted at once and clearly marked on the bill of lading before signature of acceptance. Notify APEC immediately of any conflicts. APEC will not be responsible for shortages or damages unless they are noted on the bill of lading.
In the case of packaged components (such as clips, fasteners and sealants, etc.), the quantities are marked on their container and should be checked against the bill of materials. APEC must be notified of any shortages or concealed damage within 15 days of delivery.
4.2 Equipment For Unloading and LiftingHoisting equipment is necessary to unload and posi-tion the panels and accessory crates for site storage and installation. The equipment must have sufficient capacity and reach to place the material where it is required for efficient installation.
Slings will be required to minimize panel damage. The recommended slings are nylon straps of 6” minimum width and of sufficient length to accommodate the panel bundle girth.
A spreader bar will be required for the longer panel crates to ensure correct sling spacing and uniform lifting. The spreader bar must be large enough to handle the maxi-mum panel bundle weight and length.
A forklift is handy for unloading and placing shorter panel and accessory crates.
4.3 Lifting Roof Panel Bundles
Under normal conditions, panel crates less than 35’ long can be lifted with two slings spaced at third points. Panel crates longer than 35’ can be lifted with three slings located at quarter points using a spreader bar to achieve correct sling spacing for uniform lift.
Slings should be located under the cross boards. Loads should always be checked for secure hook-up,
proper balance, and lift clearance. Tag lines should be used if necessary to control the load during lifting, espe-cially if operating in the wind.
Panel crates less than 25’ long may be lifted with a forklift only if the forks are spread at least 5’ apart and blocking is used to prevent panel damage by the forks.
4.1 Material Inventory
F_TS0_001R00BRS
PageDwg: Date: February 2012
7
ET1-1-R0
TS-324™ Roof System Installation Guide4.0 RECEIVING & HANDLING ROOF MATERIALS
4.4 Field Storage of Roof Materials
Upon acceptance of the shipment, the customer or their representative is responsible for proper handling, storage and security of the roof materials. APEC is not liable for damage or loss of materials at the job site.
The roof panel bundles should be stored on the job site in accordance with the following recommendations:
A. Store panels in a protected area, out of stand-ing water and drifting snow, etc.
B. Elevate panels with blocking to allow air circula-
tion under the bundle.
C. Slope panels for drainage of moisture from the panels.
D. As necessary, cover panels with waterproof tarp, allowing for air circulation (do not wrap tarp under panel crate or restrict air move-ment).
E. Inspect panels daily for moisture accumula-tion.
F. If panel bundles contain moisture, the panels should be dried and re-stacked. Use care in re-stacking to avoid damage to panels.
G. Opened or re-stacked panel bundles should be secured to prevent wind damage.
When moving panel bundles, extreme caution should be taken to prevent damage to the panel edges. Un-crated panels should be supported at each end and at 8’ spaces.
All bundles or loose panels on the roof should be banded to the roof structurals at the end of each workday. On steep roofs, provisions should be taken to prevent panels and panel crates from sliding off the roof. Be sure to set panel bundles on the roof in the proper direction for the installation sequence.
Trim and accessories should be stored in a secure area and protected from damage, weather and theft. Fasten-ers, sealants, closures, etc. should be stored out of the weather and protected from contamination.
Panel Bundle
Blocking
Stack blocking so bundle is sloped for drainage
F_TS0_002R00BRS
PageDwg: Date: February 2012
8
ET1-1-R0
TS-324™ Roof System Installation Guide4.0 RECEIVING & HANDLING ROOF MATERIALS
4.5 Handling Individual Roof Panels
To lift individual panels, lift one side of the panel by the seam, letting it hang naturally to prevent buckling. Pick-up points should not be more than 10’ apart. Do not pick-up panels by the ends only, or in a flat position.
If the individual panels are to be lifted to the roof by hand line, the common method is to use the vice grip “C” clamps. Position the clamps on the flat of the panel,
as close as possible to one edge so the panel is lifted in a vertical position. The jaws of the vice grips must be padded to prevent damage to the panel surface. The clamps should be uniformly spaced, no more than 10’ apart and the hand lines must be pulled in unison so that uneven lifting does not buckle the panel. Be sure the clamps are tight on the panel and the line is secure to prevent dropping the panel, which can result in personal injury and property damage.
Roof Panel
10’ Maximum
10’ Maximum
F_TS0_003R00BRS
PageDwg: Date: February 2012
9
ET1-1-R0
TS-324™ Roof System Installation Guide
5.1 Proper ToolsBefore starting paneling, be sure that the proper equipment and tools are on hand. The tools must be in good operating condition and operators should adhere to safety precautions at all times.
Improperly operating tools, too few tools, inadequate power source, or other equipment deficiencies slow down the installation process. The cost of inefficient working is usually greater than the cost of providing good equipment.
5.0 ROOF INSTALLATION BASICS
5.2 Equipment ListThe following tools and equipment should be consid-ered for efficient installation of the APEC standing seam panel. Actual tools and equipment required may vary due to variations in building type and con-struction.
This list should not be interpreted as a limitation to your inventory of installation equipment.
*TS-324 Rib Clamp — Minimum of (4) required*TS-324 Seam Clamp — Minimum of (2) required*TS-324 Motorized Seaming Machine*ESE #812 Manual Seaming ToolScrew Guns — Designed for use with self-drilling screwsSocket Extensions — 6” extension for screw gunHex Socket Heads — 5/16” and 3/8”, magneticDrill Motor — 1/4” capacityDrill Bits — AssortmentSheet Metal Cutter — or power shears or nibbler“C” Clamps — vise grip type with swivel padsPop Rivet Tool — 1/8” capacitySheet Metal Shears — left and right cut
Hack Saw — with metal cutting bladeSteel Measuring Tape — 12’, 50’, 100’Nylon String LinesChalk Line (NO red chalk)BroomsMarking Pen (NO lead pencils)Caulk Guns — for 1/10 gallon sealant tubesPower Source and Extension Cords — capable of han-
dling the total equipment requirements, including 20-amp seamer machine, without power drop due to extension cord length.
*These tools are specifically designed for the APEC Roof Panel and are available from the APEC.
5.3 SealantsA. TEMPERATURE EFFECTSTemperature extremes must be considered during installation of the roof due to the sensitivity of sealants. The recommended installation temperature range is 20º F to 120º F. At colder temperatures, the sealant stiffens resulting in loss of adhesion and compress-ibility. At hotter temperatures, the sealant becomes too soft for practical handling. On cold but sunny days, the panel’s surface may become warm enough to accept the application of a heated sealant even though the air temperature is below 20º F.
When overnight temperatures fall below freezing, the sealant should be stored in a heated room so it will be warm enough to use the following day. On hot days, the sealant cartons should be stored off the roof in a cool and shaded area. While on the roof, sealant rolls should be kept shaded until actual use.
In very cold weather, it is recommended that the fas-teners be tightened slowly and only tight enough that the sealant is in full contact with the panel or flashing. Then on the next sunny day, complete the tightening process after the sun warms the panel and flashing surfaces.
B. CONTAMINATIONTo ensure proper adhesion and sealing, the sealant must have complete contact with adjoining surfaces and achieve 30% compression. Contaminants such as water, oil, dirt and dust prevent such contact. The panel and flashing surfaces must be dry and thoroughly cleaned of all contaminants. Before applying tape sealant, the seal-ant should be checked for contaminants. If the sealant surfaces are contaminated, it must not be used.
During cool weather, condensation or light mist can ac-cumulate on the panel and flashing surface and not be easily noticed. It is recommended that sealants always be kept under protective cover and that the panel and flashing surfaces be wiped dry immediately before in-stallation.
Tape sealant is provided with a protective paper to reduce contamination. Incomplete removal of the protective paper will prevent the sealant’s adhesion to the panel or flashing surfaces. Always verify that the protective paper is completely removed. Do not remove the protective paper until immediately before the panel or flashing is installed over the sealant.
PageDwg: Date: February 2012
10
ET1-1-R0
5.0 ROOF INSTALLATION BASICS
5.3 Sealants (Continued)
C. COMPRESSIONTo ensure proper adhesion and seal, the tape sealant must be compressed between the panel and flash-ing surfaces with firm and uniform pressure. In most cases, the required pressure is applied by the clamping action of screws pulling the adjoining surfaces together. However, the tape sealant’s resistance to pressure becomes greater in cold weather.
During cold weather, the fasteners must be tightened slowly to allow the sealant time to compress. If the fasteners are tightened too fast, the fastener may strip out before the sealant compresses adequately, or the panel or flash may deform in the immediate area of the fastener, leaving the rest of the sealant insufficiently compressed.
D. INSIDE CORNERSAn inside radius, such as where the panel flat meets a rib, is usually the most critical area to seal. A common mistake for the installer, is to bridge the sealant across the inside radius.
When the lapping panel or flashing is pushed into place, the bridged sealant is stretched and thinned. The seal-ant may then be too thin to adequately seal this critical area. When tape sealant is applied at an inside radius, it is recommended that the sealant be folded back on itself, then push the sealant fold into the radius. Do not tear, but cut the tape sealant to length with a box knife or equal.
5.4 FastenersA. SCREW GUNUse torque control and variable speed screw guns for driving self-drilling screws (2000-2500 RPM screw gun speeds are necessary to attain efficient drilling speeds). High tool amperage (4 to 7 AMP) is required to achieve the proper torque for proper seating, and to secure the fastener.
B. SOCKETSUse good quality magnetic sockets. Good fitting sock-ets reduce wobble and stripping of the screw heads, especially the alloy and capped heads. They also minimize objectionable paint chipping and scuffing on colored screws and minimize damage to the protective coating on unpainted screws.
Magnetic sockets collect drill shavings, which will build up and eventually prevent the socket from seating properly on the screw heads. One method of remov-ing the drill shavings is to roll up a ball of tape sealant and push the socket into the sealant.
When the socket is removed from the sealant, most of the drill shavings will remain embedded in the sealant thereby cleaning the socket. This process should be repeated as often as needed to keep the socket clear of drill shavings.
C. SOCKET EXTENSIONA 4” or 6” socket extension is recommended for installing the panel clip screws. With the extension the screw can be driven straight down without tilting the screw gun to clear the panel or clip. Since socket extensions are slow to wear out, it is usually more cost effective to purchase socket extensions and good quality sockets, rather than to purchase sockets with built-in extensions.
D. INSTALLATIONBefore starting the screw, the materials to be joined must be pressed together with foot or hand pressure. The pressure must be maintained until the screw has drilled through all the materials and the threads have engaged.
INCORRECT CORRECT
Critical:Do not allow thesealant to bridgeacross inside radiicreating voids
Fold the sealantand push the foldinto the radius
Roof PanelRoof Panel
EndlapSealant
EndlapSealant
Void
Void
Void
TS-324™ Roof System Installation Guide
F_TS0_004R00BRS
PageDwg: Date: February 2012
11
ET1-1-R0
5.0 ROOF INSTALLATION BASICS
5.4 Fasteners (Continued)
D. INSTALLATION (continued)Most self-drilling screws require 20 pounds of pressure to maintain the drilling action and to start the thread cutting action. Also, applying such pressure before starting the screw gun will usually prevent tip walking or wandering.
If too little pressure is applied, the drill point may not cut into the metal and the point will heat up and become dull. If the pressure is too heavy, the bottom material may be deflected away, causing a standoff condition, or the drill tip may be broken or split. Screws must be held perpendicular to the panel or flashing surface during starting and driving.
For proper seating of the fastener-sealing washer, the panel or flashing surface must be clean and drill shavings must be removed from under washers before seating. The fastener must be driven perpendicular to the panel surface so that the washer can seat level without warping or cupping.
Do not over drive screws. Over driving can strip the threads and/or damage the sealing washer. Use screw gun with torque control set to function properly for the combination of fastener size, hole size and material thickness.
The fastener should be driven tight enough to uniformly compress the washer but not so tight that the washer splits or rolls out from under it’s metal dome. The rec-ommended procedure is to tighten the fastener until the sealing washer just starts to visually bulge from under the metal dome.
As a good installation practice, all roof installers should carry approved oversized screws. Upon stripping or breaking a screw, the screw must be immediately re-moved and replaced with the appropriate oversized screw. Do not defer the screw replacement to be re-membered and fixed later, or to be found by the clean-up crew. The majority of such screws will be overlooked until the customer complains of leakage.
5.5 Field Cutting Panels and Flashing
A. ABRASIVE SAW PROBLEMSAbrasive saws (circular saws with friction disks) are not recommended for cutting roof panels or flashing. Abrasive saws create high heat that may burn away the protective coating from the panel edge, causing the edge to rust.
Also, abrasive saw dust contains fine, hot steel parti-cles, which accumulate on panel and flashing surfaces where they rust and can cause staining and rusting of those surfaces.
Rust caused by abrasive saw damage or abrasive dust particles can be excluded from warranty claims.
B. SHEARING METHODSIt is recommended that panels and flashing be cut with shears to provide a clean, undamaged cut. On shear cut edges, the protective coating extends to the edge of the cut and is often wiped over the edge to further protect the base metal. Whenever possible, fit the material so that the factory cut edge is exposed and the field cut edge is covered.
When field cutting complex shapes, it is usually easier to cut out a 1” wide strip using both left and right hand shears. The 1” cutout provides clearance to smoothly cut the flats and the clearance to work the shears around tight corners.
When making repetitive cuts (such as cutting panels at a hip condition) it is recommended that a template be made from a piece of drop-off panel or flash to provide fast and accurate marking of the field cut. When using panel material for the template, cut off the top portion of the panel ribs so that the template is easily laid onto the panel being marked.
C. MARKING PANELSAvoid marking the panels for cutting, etc., in a man-ner that will leave visible markings, stains, etc., on the finished roof surface. Use chalk or felt tip ink markers. Do not use graphite (lead) pencils on unpainted panel surfaces, the graphite can cause rusting of the surface.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
12
ET1-1-R0
6.0 ROOF PANEL LAYOUT
6.1 Sheeting Direction and Modularity
Although the APEC roof system is designed so it can be installed in either direction (left to right or right to left), there may be roof conditions which require a specific sheeting direction. Check the erection drawings to determine if a specific sheeting direction is required.
The recommended installation sequence is to complete each panel run from eave to ridge before starting the next panel run. This sequence will help ensure straight runs and allow the insulation to be installed immediately ahead of each panel run.
During installation of the roof, considerations must be made for maintaining panel modularity. By maintain-ing panel modularity, the roof panel sidelap and seam can be properly assembled, the proper roof coverage can be obtained, and the standard perimeter parts will fit properly without necessity of field modifications or reordering of parts, etc.Caution: Failure to maintain panel coverage width
within the specified tolerance can cause faulty roof panel seams which can result in seaming difficulty or in severe cases reduction in roof performance specifications.
The panels must be held to the width dimension of the panel as designated on the erection drawings within a 1/8” width tolerance per panel. The accumulated cover-age (start panel to finish panel) tolerance is determined by the ability to keep the panels parallel and to correctly fit and assemble the finish rake condition.
If the roof has conditions such as fixed location penetra-tions, parapets, fire walls, etc., the accumulated panel coverage may require tighter tolerances for proper fit-up and weather tightness of the roof system.
6.2 Layout & Checking for Coverage
Recommended for all roofs, but a must for large or complex roofs, is to make a layout of the actual struc-ture (field measured as described in section 3.3) so that the roof panel start and stop dimensions can be laid out to accommodate any structural misalignments.
When the optimal start and finish dimensions are de-termined, a string line should be set to precisely locate the leading edge of the start panel. After the start panel is secured and engaged with the next panel, the start panel seam will be the reference line for checking ac-cumulated panel coverage.
Panel coverage is always checked at the eave, ridge, and end splices, so that non-parallel seam (or dogleg) conditions can be detected and corrected before they become objectionable. The coverage check should be done with a measuring tape held taut and measured to the same side of the seam and always parallel to the eave, to prevent any measuring error.
Every four to six panel runs should be checked for panel modularity. This will ensure that the panels are maintaining a straight line and proper coverage is being maintained. If the panels are off module, they should be corrected by equal adjustments of the next four to six panel runs.
6.3 Appearance Considerations
Although the above stated coverage tolerance will provide for reasonable ease of installation and water tightness, such visible conditions as non-parallel panel seams, dogleg of the panel seam at the end splices,
non-parallel finish panel width, and mismatch of panel seams across the ridge, may be objectionable and should be confirmed with the customer before continuing roof installation.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
13
ET1-1-R0
7.0 INSPECTION OF ROOF ASSEMBLY DURING INSTALLATION
7.1 Importance of InspectionDuring the roof installation, all areas of the roof system assembly must be frequently inspected to ensure the correct assembly in accordance with the erection draw-ings and this installation guide.
Failure to assemble the roof system correctly will result in roof performance problems that may require costly corrective work, roof replacement and performance and damage claims, etc. Also, incorrect installation may void the performance and material warranties.
7.2 Inspection List
A. ERECTION DRAWINGSCheck that the erection drawings are available at the job site and have been reviewed for difference with the actual job conditions and differences with this instal-lation guide. Also, confirm that the drawings are the latest issue with the latest revisions and additions.
B. ROOF LAYOUTSCheck that the roof start and finish dimensions have been correctly determined based on the erection draw-ings and the actual structural conditions.
C. BEFORE INSTALLING ROOF PANELSCheck that the structural misalingments were cor-rected in accordance with Section 3.0 of this installa-tion guide.
Check that the correct eave and rake plates and eave trim are in place before installing the roof panels.
Check that the roof panel elevation, provided by the panel clip height and insulation system, matches the eave and rake plate elevation.
D. PANEL LENGTHCheck that the installed roof panels have the correct overhang at the eave and endlaps and have the correct hold back at the ridge or high eave, in accordance with the erection drawing.
E. EAVE SEALCheck that the eave sealant is in the correct position on top of the eave trim, and that the corrugation closure and eave pigtail sealant are correctly placed. Check that the eave fasteners penetrate the center of the eave sealant and into the eave plate. Check that the fasteners are not loose or stripped.
Check that the eave sealant is in complete contact with the roof panel and eave trim without any voids or gaps. Confirm that the roof panel and eave trim are clean and dry during installation and that the sealant is not wet or otherwise contaminated.
F. ENDLAP SEALCheck that the roof panel endlaps are correctly as-sembled and that the lapping panels are tightly nested without visible gaps.
Check that the sealant is in the correct position and is in complete contact with the lapped panels without any voids or gaps, especially at the radius between the panel flat and the vertical legs of the panel. Confirm that the panels are clean and dry during installation and that the sealant is not wet or otherwise contaminated.
Check that the pigtail sealant is in the correct position and seals the endlap seam notches.
Check that the cinch strap fasteners penetrate through the center of the sealant and into the back-up channel. Check that the fasteners are not loose or stripped.
Check that the endlap assembly is not bowed down caus-ing water ponding and debris accumulations.
G. RIDGE SEALCheck that the ridge closure assembly is correctly as-sembled.
Check that the sealant is in the correct position and is in complete contact with the closure and the roof panel without any voids or gaps. Confirm that the closures and roof panels are clean and dry during installation and the sealant is not wet or contaminated.
Check that the closure fasteners penetrate through the center of the sealant and into the back-up channel. Check that the fasteners are not loose or stripped.
Check that the tube sealant is installed along the back of the closure as necessary, to seal any voids around the panel seam area.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
14
ET1-1-R0
7.0 INSPECTION OF ROOF ASSEMBLY DURING INSTALLATION
7.2 Inspection List (Continued)
H. RAKE SEALCheck that the termination zee is correctly assembled with the termination zee splices correctly oriented for downhill watershed.
If there are roof panel endlaps, check that the endlap sealant contacts the termination zee sealant or that a pigtail sealant is applied for that purpose.
Check that the sealant is in the correct position above and below the roof panel.
Check that the termination zee sets fully on the seal-ant and that the sealant is in complete contact with the roof panel and the zee without any voids or gaps. Confirm that the roof panel and zee are clean and dry during installation and that the sealant was not wet or contaminated.
Check that the termination zee fasteners penetrate the center of the sealant and into the rake plate. Check that the fasteners are not loose or stripped.
I. PANEL CLIP ATTACHMENTCheck that the panel clips are correctly fitted to the panel without any distortion or damage of the clip tab. On sliding clips, check that the clip tab is centered on the clip base between the centering tabs.
Check that the clips are located along each panel side-lap at each roof structural or at the locations specified on the erection drawings.
Check that the panel clip fasteners are of the type, size, length, finish and quantity-per-clip as specified on the erection drawings.
Check that the panel clip fasteners are not loose or stripped. In the case of multi-layered construction, verify that the fasteners penetrated and engaged the specified structural member.
J. SIDELAPCheck that the panel sidelaps are on module (held to within the 1/8” panel width tolerance) and are as-sembled so that the male and female panel edges and panel clips are properly nested together prior to seaming.
Check that the full length of each sidelap seam is cor-rectly seamed.
Check that the factory installed sidelap sealant is in the correct position without voids or interruptions and is not damaged, wet or otherwise contaminated.
Check that the panel coverage tolerance does not exceed 1/8” per panel and that the accumulated coverage will allow proper fit and assembly of the end dams and finish rake condition and any other critical fit conditions such as penetrations, parapets, etc.
K. FLASHING AND PENETRATIONSCheck that all flashing (including penetrations) are correctly assembled and tightly fitted. Check that the required sealants are correctly positioned and in com-plete contact with the adjoining surfaces without voids or interruptions. Confirm that the sealants and adjoining surfaces are clean and dry during installation.
Check that the flashing splices are correctly lapped, sealed and fastened.
Check that the flashing is sufficiently pitched to shed water and eliminate ponding areas, especially at the critical splices, endlaps and corners.
Check that the fasteners are of the specified type, size, length, finish and spacing. Check that the fasteners are not loose or stripped. Check that the sealing washers are in full contact with the flashing surface and not distorted, split or otherwise damaged.
Along the rakes, high eave transitions and fixed penetra-tions, check that the flashing is not constrained and will allow for the roof’s expansion/contraction movement.
L. SURFACE CONDITIONSDamaged roof system surfaces are subject to corrosion and performance problems and may void the material and performance warranties.
Check that the panel and flashing surfaces are not be-ing subjected to abusive conditions such as: careless handling of panels and flashing, excessive roof traffic, abrasive or contaminated footwear, rough handling of materials, tools and equipment, or contact with abrasive materials or residue.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
15
ET1-1-R0
7.0 INSPECTION OF ROOF ASSEMBLY DURING INSTALLATION
7.2 Inspection List (Continued)
L. SURFACE CONDITIONS (continued)Check that the panel and flashing surfaces are not being subjected to exposed metal objects and materials left on the roof such as: tools, material drop-off, fasteners, wire, staples, drill and nibbler chips, saws and file particles. In the process of rusting, these materials will absorb the panel’s protective coating, thus leaving the panels exposed to rusting.
Check that the panels and flashing are not being subjected to long term wet conditions such as: standing water, consistent sources of steam, mist, spray, dripping or runoff, wet debris, wet insulation or other moisture holding material.
Check that the panels and flashing are not subjected to direct contact or runoff from corrosive materials such as: copper pipes and flashing, uncured cement, treated lumber anti-icing chemicals, strong solvents or other corrosive materials.
Check that graphite pencils were not used to mark on unpainted surfaces. The graphite marks can cause rusting.
Check that the roof materials are not subjected to damaging heat such as: cutting torches, abrasive saws, etc.
M. UNSPECIFIED MATERIALSUse of the wrong materials may cause installation and performance problems and may void the performance and material warranties.
Check that all installed roof system materials, especially sealants and fasteners, are only those which are provided or specified by APEC for your specific project and are used only as specified on the erection drawings and this installation guide.
APEC cannot be responsible for the performance of roof materials that are not provided, specified or approved by APEC.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
16
ET1-1-R0
8.0 STANDARD PARTS
8.1 General
The following details provide a basic description and graphic illustrations of the standard roof assembly parts. The purpose of these details is to assist the erector in the correct selection and identification of parts.
Because of the many variations in conditions, it is important that you review the job conditions to identify the specific parts required for your job.
Review the erection drawings for any special parts or parts which are different from the standard parts shown in these details. If differences exist, the erection draw-ings will have preference.
For proper fit-up, sealing and fastening, and to help ensure the roof assembly’s weathertightness, structural capability, durability and appearance, the correct parts must be used. Do not use parts other than those speci-fied on the erection drawings.
TS-324™ Roof System Installation Guide
PageDwg: Date: February 2012
17
ET1-1-R0
8.0 STANDARD PARTS
Part No. TS324(Specify gauge, finish & length)
24 or 22 gauge Steel Painted or Galvalume Finish Striated Pan Factory notched for endlap Factory punched holes
(24" wide panel)
24"
3"
ROOF PANELROOF PANEL (24” wide panel)• 24 or 22 guage Steel• Painted or Galvalume Finish• Striated Pan• Factory notched for endlap• Factory punched holes
TS-324™ Roof System Installation Guide
F_TS0_500R00BRS
PageDwg: Date: February 2012
18
ET1-1-R0
8.0 STANDARD PARTSClips with 2 holes are not FM approved.
TS-324™ Roof System Installation Guide
F_TS0_500R00BRS
Part No. CC324 (Specify finish)Weight - 0.24
PURLIN STABILIZING FLOATING CLIP (for 1/2” stand-off)• 20 ga. Galvanized Steel, Tab• 16 ga. Galvanized Steel, Base
FIXED CLIP (for 1/2” stand-off)• 20 ga. Galvanized Steel
Part No. MPS602Weight - 0.40
Part No. MPS602
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
4 5/16"
Base
Tab
3 1/
2"
(for 1/2" stand-off)PURLIN STABILIZING FLOATING CLIP
Part No. MPS603
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
4 5/16"
Base
Tab
4 1/
2"
(for 1 1/2" stand-off)PURLIN STABILIZING FLOATING CLIP
Painted or Galvalume Finish 22 gauge Steel
Factory punched hole
Part No. CC324 (Specify finish)
2"
5 1/16"
CORRUGATION CLOSURE
3 1/4"
3"
3 1/4"
3 3/
8"
3 1/4"
4 3/
8"
FM ApprovedUL listed
FM ApprovedUL listed
FM ApprovedUL listed
FM ApprovedUL listed
FM ApprovedUL listed
CORRUGATION CLOSURE• 22 gauge Steel• Painted or Galvalume Finish• Factory punched hole
FIXED CLIP (for 0” stand-off)• 20 ga. Galvanized Steel
Part No. FC461Weight - 0.18
Part No. FC462Weight - 0.20
PURLIN STABILIZING FLOATING CLIP (for 1-1/2” stand-off)• 20 ga. Galvanized Steel, Tab• 16 ga. Galvanized Steel, Base
FIXED CLIP (for 1-1/2” stand-off)• 20 ga. Galvanized Steel
Part No. MPS603Weight - 0.45
Part No. FC463Weight - 0.25
PageDwg: Date: February 2012
19
ET1-1-R0
8.0 STANDARD PARTSTS-324™ Roof System Installation Guide
F_TS0_500R00BRS
Part No. TZ310 (Specify gauge and finish)
3"
1 1/4"
1 1/4"
ENDLAP BACK-UP PLATE (for 24” panel)• 16 gauge Galvalume Steel• Factory punched holes
Part No. BP324Weight - 2.40
END DAM (for 24” wide panel)• 24 gauge Steel• Painted or Galvalume Finish• Factory punched holes
Part No. ED324 (Specify finish)Weight - 1.09
Part No. SS-Z3 (Specify gauge & length)Weight - 4.54 (24 guage)Weight - 5.68 (22 guage)
TERMINATION ZEE• 24 or 22 guage Steel• Painted or Galvalume finish• 10’-2” length
(for 24" panel)
Part No. BP324
Factory punched holes 16 ga. Galvalume Steel
4 3/4"
18 3/4"
ENDLAP BACK-UP PLATE
Part No. ED324 (Specify finish)
24"
3"
Floating Clip (for 1-1/2” stand-off)• 20 ga. Galvanized Steel, Tab• 16 ga. Galvanized Steel, Base
Part No. MPS603-3Weight - 0.39Part No. MPS602-3
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
4 5/16"
Base
Tab
3 1/
2"
(for 1/2" stand-off)FLOATING CLIP
Floating Clip (for 1/2” stand-off)• 20 ga. Galvanized Steel, Tab• 16 ga. Galvanized Steel, Base
Part No. MPS602-3Weight - 0.35
Do not use onFM RoofsUL LIsted
Do not use onFM RoofsUL LIsted
Part No. MPS603-3
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
4 5/16"
Base
Tab
4 1/
2"
(for 1 1/2" stand-off)FLOATING CLIP
(for 3/8" stand-off)
10'-0" length 16 ga., 50 ksi Galvanized Steel
Part No. PP038
Factory punched slots
1 1/2"
1 1/2"
PERIMETER PLATE
PERIMETER PLATE (for 3/8” stand-off)• 16 gauge, 50 ksi Galvanized Steel• 10’-0” length• Factory punched slots
Part No. RP038Weight - 8.47
PageDwg: Date: February 2012
20
ET1-1-R0
Part No. PP138
1 1/2"
1 1/2"
CLIP FASTENER • Panel Clip to Secondary• Eave Plate to Secondary• Inside Closure• Panel Clip to Metal Decking
SHOULDER FASTENER • Perimeter Plate to Secondary at Rake• Eave Plate to Secondary (Floating Only)
PANEL FASTENER• Panel to Perimeter Plate• Panel Endlaps• Panel To Perimiter Plate (@ Zee)
PANEL FASTENER• Panel to Backup PL @ Ridge & Hi Side
• 1/4"-14" Long Life Driller• 5/16" Hex Washer Head With Sealing Washer
• #17 x 1” Self Tapping Screw (Type AB Point)• 3/8” Hex Washer Head with Sealing Washer
• 1/4"-14 x 1 1/4" Driller• 3/8" Hex Head No Washer
• 1/4"-14 x 1 1/4" Shoulder Tek 2
Part No. RS2
Part No. RS8
PERIMETER PLATE (for 1 3/8” stand-off)• 16 gauge, 50 ksi Galvanized Steel Min.• 10’-0” length• Factory punched slots
Part No. RP138Weight - 8.47
Part No. RS1 Part No. RS4
8.0 STANDARD PARTS
* Screw length may vary based on roof system
TS-324™ Roof System Installation Guide
F_TS0_500R00BRS
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
STITCH FASTENER • Ridge & Other Flashing to Outside Closure• Gutter to Panel• Gutter to Strap• Trim to Trim• Eave Trim to Panel
• 1/4"-14 x 7/8" Long Life Lap Tek Driller• 5/16" Hex Washer Head with Sealing Washer
Part No. RS3
PageDwg: Date: February 2012
21
ET1-1-R0
8.0 STANDARD PARTSTS-324™ Roof System Installation Guide
F_TS0_500R00BRS
* Screw length may vary based on roof system
Part No. RS9
CLIP FASTENER • Panel Clip to Wood Decking
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
• #10 - 12 x 1" Woodmate• 1/4" Hex Head
PART #: MS05
5/32
"
7/8"
Paper Backing
Sealant
1/2"
3/32
"
PART #: MS78
5/32" x 7/8" DOUBLE BEAD TAPE SEALANT
SSR PANEL EAVES
3/32" x 1/2" ROLL TAPE SEALANT
"R" PANEL ENDLAP, SIDELAP"R" PANEL RIDGE, EAVE, RAKE
5/32
"
Paper Backing
Sealant2 1/2"
PART #: MS250
5/32" x 2 1/2" TRIPLE BEAD TAPE SEALANT
ROOF CURBS
5/32
"
Paper Backing
Sealant1 1/4"
PART #: MS125
5/32" x 1 1/4" TRIPLE BEAD TAPE SEALANT
SSR PANEL ENDLAPSVALLEYS
SSR PANEL RIDGEFLASHINGS (SSR ROOFS)FLASHINGS (PBR ROOFS)
PART #: TS3
URETHANE GUN GRADE SEALANTCOLORS: BROWN, WHITE, GRAY
TAPE SEALANT • SSR Panel Endlaps
TAPE SEALANT • Roof Curbs• Valleys
• 5/32" x 1 1/4" Triple Bead Tape Sealant • 5/32" x 2 1/2" Triple Bead Tape Sealant
Part No. MS125 Part No. MS250
CLIP FASTENER • Clip to Joist• Girt Clip to Secondary (5 Screws = (2) 1/2" Ø A 325 Bolts)• Metal Deck to JoistPART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
• 5/16" Hex Head No Washer• 12-24 x 1 1/4" TEK 4.5 Driller
Part No. RS5
PART #: RS5
DRILL POINT
12-24 x 1 1/4" TEK 4.5 DRILLER
CLIP TO JOIST
1 1/4"
GIRT CLIP TO SECONDARY (5 SCREWS = (2) 1/2"Ø A325 BOLTS)
5/16" HEX HEAD NO WASHER
PART #: RS1
1/4"-14 x 1 1/4" DRILLER
DRILL POINT
3/8" HEX HEAD NO WASHER
PANEL CLIP TO SECONDARYEAVE PLATE TO SECONDARYINSIDE CLOSURE
1/4"-14 THREAD
PANEL CLIP TO METAL DECKING
*1 1/4"
PART #: RS2
DRILL POINT
1 1/4"
5/16" HEX WASHER HEAD WITH SEALING WASHER
PANEL TO PERIMETER PLATEPANEL ENDLAPS
1/4"-14x1 1/4" LONG LIFE DRILLER
PANEL TO PERIMETER PLATE (@ ZEE)
PART #: RS3
5/16" HEX WASHER HEAD WITH SEALING WASHER
RIDGE & OTHER FLASHING TOOUTSIDE CLOSURE
7/8"
DRILL POINT
GUTTER TO PANEL
GUTTER TO STRAP
TRIM TO TRIM
EAVE TRIM TO PANEL
1/4"-14 x 7/8" LONG LIFE LAP TEK DRILLER
PART #: RS4
DRILL POINT
1/4"-14 x 1 1/4" SHOULDER TEK 2
PERIMETER PLATE TO SECONDARY
1 1/4"
AT RAKE
EAVE PLATE TO SECONDARY(FLOATING ONLY)
*
*
PART #: RS6
DRILL POINT
1/4"-20 x 1 1/4" SHOULDER TEK 4
PERIMETER PLATE TO JOIST AT
1 1/4"
RAKE
EAVE PLATE TO JOIST(FLOATING ONLY)
5/16" HEX HEAD NO WASHER
12 x 1" PANCAKE HEAD DRILLER#2 PHILLIPS/SQUARE DRIVE
1"
PART #: RS7 RAKE ANGLE (PM1) TO PURLIN
STRAPPING TO SECONDARY MEMBER
1"
PART #: RS8 PANEL TO BACKUP PL @ RIDGE & HI SIDE
3/8" HEX WASHER HEAD WITH SEALING WASHER #17 x 1" SELF TAPPING SCREW (TYPE AB POINT)
TYPE AB POINT
1/4" HEX HEAD#10-12 x 1" WOODMATE
1"
PART #: RS9 PANEL CLIP TO WOOD DECKING
TYPE A POINT
Mandrel
Rivet Body
Head
PART #: BR1 EAVE TRIM TO PERIMETER PLATE
STAINLESS STEEL1/8" DIA. x 3/16" LENGTH
TRIM TO TRIM
METAL DECK TO JOIST
1"DRILL POINT
PART #: RS10 DECK SIDELAPS
5/16" HEX HEAD NO WASHER#10-16 x 1" DP3.
*
POP RIVET • Eave Trim to Perimeter Plate• Trim to Trim
• Stainless Steel• 1/8" Dia. x 3/16" Length
Part No. BR1
PART #: MS05
5/32
"
7/8"
Paper Backing
Sealant
1/2"
3/32
"
PART #: MS78
5/32" x 7/8" DOUBLE BEAD TAPE SEALANT
SSR PANEL EAVES
3/32" x 1/2" ROLL TAPE SEALANT
"R" PANEL ENDLAP, SIDELAP"R" PANEL RIDGE, EAVE, RAKE
5/32
"
Paper Backing
Sealant2 1/2"
PART #: MS250
5/32" x 2 1/2" TRIPLE BEAD TAPE SEALANT
ROOF CURBS
5/32
"
Paper Backing
Sealant1 1/4"
PART #: MS125
5/32" x 1 1/4" TRIPLE BEAD TAPE SEALANT
SSR PANEL ENDLAPSVALLEYS
SSR PANEL RIDGEFLASHINGS (SSR ROOFS)FLASHINGS (PBR ROOFS)
PART #: TS3
URETHANE GUN GRADE SEALANTCOLORS: BROWN, WHITE, GRAY
TAPE SEALANT • SSR Panel Eaves• SSR Panel Ridge• Flashings (SSR Roofs)
• 5/32" x 7/8" Couble Bead Tape Sealant
Part No. MS78
PART #: MS05
5/32
"
7/8"
Paper Backing
Sealant
1/2"
3/32
"
PART #: MS78
5/32" x 7/8" DOUBLE BEAD TAPE SEALANT
SSR PANEL EAVES
3/32" x 1/2" ROLL TAPE SEALANT
"R" PANEL ENDLAP, SIDELAP"R" PANEL RIDGE, EAVE, RAKE
5/32
"
Paper Backing
Sealant2 1/2"
PART #: MS250
5/32" x 2 1/2" TRIPLE BEAD TAPE SEALANT
ROOF CURBS
5/32
"
Paper Backing
Sealant1 1/4"
PART #: MS125
5/32" x 1 1/4" TRIPLE BEAD TAPE SEALANT
SSR PANEL ENDLAPSVALLEYS
SSR PANEL RIDGEFLASHINGS (SSR ROOFS)FLASHINGS (PBR ROOFS)
PART #: TS3
URETHANE GUN GRADE SEALANTCOLORS: BROWN, WHITE, GRAY
PageDwg: Date: February 2012
22
ET1-1-R0
F_TS0_527R01BRS
JULY 07
3.3511
.29
11.97
3.35
SOUTHERN STYLE GUTTER SUPPORT• G-90 galvanized 50 ksi• 0.052 thick 18 ga.
NORTHERN STYLE GUTTER SUPPORT• G-90 galvanized 50 ksi• 0.052 thick 18 ga.
Part No. CC 601Weight - 0.74
Part No. CC 602Weight - 0.71
8.0 STANDARD PARTS
SPACER BLOCK (for 24” wide panel) (Optional)• Extruded Polystyrene Foam• 3/8”, 5/8”, or 1” Thick
Part No. SB324 (Specify thickness)
3"
Part No. SB324 (Specify thickness)
Extruded Polystyrene Foam 3/8", 5/8", or 1" Thick
Thi
ckne
ss
24" (NOMINAL)
(for 24" wide panel)SPACER BLOCK
TS-324™ Roof System Installation Guide
F_TS0_500R00BRS
Part No. MPS 604-3Weight - 0.35
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
SEALANTLESS PURLIN STABILIZING FLOATING CLIP (for 1/2" stand-off)
UL Listed Do NOT use on FM roofs
4 5/16"
3 1/
2"
Tab
Base
Part No. MPS 604Weight - 0.40
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
SEALANTLESS PURLIN STABILIZING FLOATING CLIP (for 1/2" stand-off)
UL Listed Do NOT use on FM roofs
4 5/16"
Base
Tab
3 1/
2"
Part No. RS3 (Specify color)
Urethane Gun Grade Sealant
1/10 Gal. Tubes Color-brown, white, or grey
TUBE SEALANT
Part No. TS3 (Specify color)
TUBE SEALANT• Urethane Gun Grade Sealant• Color - brown, white, or grey• 1/10 Gal. Tubes
PageDwg: Date: February 2012
23
ET1-1-R0
8.0 STANDARD PARTSTS-324™ Roof System Installation Guide
Part No. MPS 605Weight - 0.45
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
SEALANTLESS PURLIN CLIP(for 1/2" stand-off)
UL Listed Do NOT use on FM roofs
4 5/16"
Base
Tab
4 1/
2"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1/2" stand-off)
UL Listed FM Approved Tab
Base
Part No. BA 602-12Weight - 0.80
3 1/
2"
12"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1/2" stand-off)
UL Listed FM Approved
Tab
Base
Part No. BA 602-6Weight - 0.48
3 1/
2"
6"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1/2" stand-off)
UL Listed FM Approved
Tab
Base
Part No. BA 602-8Weight - 0.58
3 1/
2"8"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1/2" stand-off)
UL Listed FM Approved Tab
Base
Part No. BA 602-16Weight - 1.00
3 1/
2"
16"
Part No. MPS 605-3Weight - 0.39
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
SEALANTLESS PURLIN CLIP(for 1 1/2" stand-off)
UL Listed Do NOT use on FM roofs
4 5/16"
4 1/
2"
Tab
Base
F_TS0_500R00BRS
PageDwg: Date: February 2012
24
ET1-1-R0
8.0 STANDARD PARTSTS-324™ Roof System Installation Guide
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1 1/2" stand-off)
UL Listed FM Approved
Tab
Base
Part No. BA 603-16Weight - 1.20
4 1/
2"
16"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1 1/2" stand-off)
UL Listed FM Approved
Tab
Base
Part No. BA 603-12Weight - 0.90
4 1/
2"
12"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1 1/2" stand-off)
UL Listed FM Approved Tab
Base
Part No. BA 603-8Weight - 0.60
4 1/
2"
8"
20 ga. Galvanized Steel, Tab 16 ga. Galvanized Steel, Base
HIGH WIND PURLIN CLIP (for 1 1/2" stand-off)
UL Listed FM Approved
Tab
Base
Part No. BA 603-6Weight - 0.50
4 1/
2"
6"
F_TS0_500R00BRS
PageDwg: Date: February 2012
25
ET1-1-R0
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
The following details provide graphic illustrations of the roof assembly steps. The purpose is to instruct the erector in correct and efficient assembly of the roof system.
Because of the many variations in conditions, it is im-portant that you review the job to identify and isolate the specific installation details required for your job.
Review the erection drawings for differences with these details. If differences exist, the erection drawings have precedence.
These details are arranged in a step-by-step sequence. Following this sequence ensures correct assembly and ensures that the part to be worked on will be readily accessible for the next assembly step.
Do not shortcut these assembly steps without careful consideration of the possibility of incorrect or omitted assembly and the resulting corrective rework.
To minimize confusion, the details are always oriented so that the view is from eave to ridge, with the starting rake at the left and finish rake at the right. Refer to the erection drawings to determine the required sheeting direction and rake conditions.
To help ensure weathertightness, the details emphasize proper fit-up, sealing and fastening. It is most important that only the specified sealants and fasteners be used for each condition and that they be installed correctly as shown on these details and the erection drawings.
Be sure that these critical instructions are reviewed of-ten and the roof assembly is checked at each assembly step.
9.1 GENERAL
PageDwg: Date: February 2012
26
ET1-1-R0
TS-324™ Roof System Installation Guide
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
The details in this section will show the installation of the eave perimeter plate, rake perimeter plate, start clips, eave trim, eave sealant and the first run of insu-lation. These are parts that must be installed before the roof panel installation can begin.
This view shows the roof system oriented for a left-to-right sheeting direction. For right-to-left sheeting, reverse the parts orientation.
On this view, the starting rake is shown with starting clips (for a starting panel) and the finish rake is shown with a rake perimeter plate (for a termination panel). Some buildings may require a rake perimeter plate at the start-ing rake. Refer to the erection drawings for the required rake conditions.
Rake AngleEave Structural
Perimeter Eave Plate
Rake Angle
Eave Trim
Starting Clips (typ.)
Ridge Roof Structural
Roof Structurals (typ.)
SHEETING DIRECTION
Insulation Starting Run
Perimeter Rake Plate
Rake Angle
Preparation For Roof Panel Installation
9.0 ROOF INSTALLATION DETAILS
F_TS0_005R00BRS
PageDwg: Date: February 2012
27
ET1-1-R0
TS-324™ Roof System Installation Guide
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
The eave perimeter plate provides a solid attachment surface for the eave end of the roof panel.
The eave perimeter plate must be installed before the roof insulation is placed over the structurals.
Before installing the eave perimeter plate, check that the eave structural members are in a straight alignment from rake to rake. Shim the eave perimeter plate as necessary, to provide a level roof line.
Install the starting and finish ends of the eave perimeter plates flush with outer face of rake angle.
Install the outer edge of the eave perimeter plate flush with the outside face of the wall panel.
Tightly butt-join the eave perimeter plates and fasten to the eave structural as shown.
Eave Structural
Outer edge
Wall Panel
Butt Joint(typ.)
Start Perimeter Plateflush with face
of wallOuter face
6"
6"6"
Roof Structural(typ.)
Rake Angle
Clip Fastener12" O.C.
of Rake Angle
of Perimeter Plate
Perimeter Plate
9.0 ROOF INSTALLATION DETAILS
F_TS0_006R00BRS
PageDwg: Date: February 2012
28
ET1-1-R0
TS-324™ Roof System Installation Guide
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
The appropriate height clips are used as start clips.
Refer to the erection drawings and the structural layout (as described in Section 6.2) to determine the start dimension.
The position of the start clips establishes the starting roof panel alignment. It is very important that the start clips are installed in a straight line, parallel to the rake line.
If the rake angles have been installed true and square, the edge of the rake angle can be used to align the start clips.
If the rake angle is not true and square, a chalk line should be used to guide the installation of the start clips.
Locate the start clips at the spacing and fasten to the rake angle, as shown.
Eave Structural
12" Clip Fastener
@ each Purlin
(typ.)Roof Structural
Rake Angle
Refer to erection drawingsfor structural fastener
type and quantity
PerimeterPlate
StartClip
NOTE
9.0 ROOF INSTALLATION DETAILS
F_TS0_007R00BRS
PageDwg: Date: February 2012
29
ET1-1-R0
TS-324™ Roof System Installation Guide
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
Place the upper lip of the eave trim over the eave perimeter plate as shown, and align the face of the eave trim with the face of the wall panel.
Install the starting and finish ends of the eave trim flush with the ends of the eave perimeter plate.
The eave trim provides a water seal between the roof panel and the wall panels. All laps of the eave trim must be sealed with tube sealant and rivets as shown to mini-mize water entry.
Fasten each piece of eave trim to the eave plate with three blind rivets. The rivets will hold the trim in position until the roof panels are installed and fastened.
Starting Eave Trim
Eave Trim Splice
Wall Panel
of Rake AngleTrim flush with face
Start & finish Eave
Blind Rivet1/8" dia.
end and atat each
Eave Trimcenter of
Perimeter Plate
Rake Angle
Blind Rivet1/8" dia.
TrimEave
21 "
Tube Sealant3/16" dia. x 1"
Pigtail
Tube Sealant3/16" dia.
Eave Trim
121 "
2" lap
Eave Trim
Eave Trim
9.0 ROOF INSTALLATION DETAILS
F_TS0_008R00BRS
PageDwg: Date: February 2012
30
ET1-1-R0
TS-324™ Roof System Installation Guide
Apply a continuous strip of endlap sealant along the top edge of the eave trim.
Align the outer edge of the sealant flush with the outer edge of the eave trim.
Do not remove the paper backing from the sealant at this time.
Until the roof panels are installed, the eave sealant is vulnerable to damage from foot traffic or dragging mate-rial over the eave. Do not step on or otherwise damage the sealant.
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
Rake Angle
Eave Trim
Endlap Sealant (set flush withouter edge of eave trim)
Extend sealant1/2" beyond endof Eave Trim
Outer edgeof Eave Trim
9.0 ROOF INSTALLATION DETAILS
F_TS0_009R00BRS
PageDwg: Date: February 2012
31
ET1-1-R0
TS-324™ Roof System Installation Guide
9.2 PREPARATION FOR ROOF PANEL INSTALLATION
Refer to the erection drawings to determine the specific insulation required for the project. In all cases, refer to the insulation manufacturer’s instructions for proper insulation installation and vapor seal assembly. This detail shows fiberglass blanket insulation, which is the most commonly used insulation for metal standing seam roofs.
The leading edge of each insulation run should extend approx. 12” beyond the leading edge of the roof panel. This will allow for easy assembly of the vapor barrier seal between insulation runs.
With four foot or six foot wide insulation, the first run should be installed to only cover three feet or five feet
respectively. The extra foot of width can be cut or lapped over the rake.
Use double-faced tape along the backside of the eave strut and along the rake angle to hold the insulation in place until the roof panel is installed.
In high wind areas or when using high stand-off clips, use the metal insulation retainer straps to secure the insulation to the low flange of the eave plate. In all cases, do not extend the end of the insulation onto the high flange of the eave perimeter plate.
Note:
#12 Fastener
InsulationEnd of
Optional Insulation
Edge of Insulation
Eave Structural
Vapor Barrier TabInsulation
Roof Structural
Start Clip (typ.)
Clamping Strap
(typ.)
Step of
(set behind step
Roof Insulation(starting run)
3' or 5'
Insulation clamping strap and fasteners arenot provided with the roof system.
@ 12" O.C.
(set flush with face ofrake angle)
of Perimeter Plate )
Perimeter Plate
Perimeter Plate
9.0 ROOF INSTALLATION DETAILS
F_TS0_010R00BRS
PageDwg: Date: February 2012
32
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
The details in this section show the installation of the starting and intermediate roof panels.
The roof panel endlap details are shown as an intergral part of the roof panel installation. If the project does not require roof panel endlaps, the endlap details are clearly identified and can be disregarded.
The termination roof panels require specific instal-lation and are shown in a later section.
Rake Angle
Starting
Roof Panel Endlap
Eave Strut
Rake Angle
Roof Structurals (typ.)
Ridge RoofStructural
Eave Trim
InsulationRoof
IntermediateRoof Panel
Perimeter Plate
Roof Panel
(Staggered)
Minor Ribs Not Shown
9.0 ROOF INSTALLATION DETAILS
F_TS0_011R00BRS
PageDwg: Date: February 2012
33
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Throughout these instructions the references to the panel will be made using the terms shown on the above illustration.
The APEC Steel roof panel is designed, so it can be sheeted in either direction, (left-to-right) or (right-to-left). Check the erection drawings and job conditions to determine if the roof must be sheeted in a specific direction.
The factory pre-punched holes are NOT to be used at the eave to install gutter or eave trim. Pre-punched holes are to be used for back up plate installation only.
The leading edge of the roof panel is the edge towards the sheeting direction. On the APEC Steel roof panel, the male seam is the always the leading edge.
Before loading the panels onto the roof structurals, orient the panels so that the male seam is the lead-ing edge.
PANEL SECTION
Female Seam Male Seam
Factory Holes
Seam Sealant(factory applied
Factory Holes - see note below
Male RibFemale Rib
in the seam)
Panel Length
Panel Width 24"
2"
Female Seam
Pan
(trailing edgeof panel)
Pan
2"
1"
2"Factory Notch
Factory Notch2"
Factory Notch
Factory Notch
5/8"3/4"
1"
Seam Sealant
3"
2"
24"
18 3/4" 2 5/8"2 5/8"
3 1/
16"
of panel)(leading edgeMale Seam
2"Factory Notch
2"
FactoryNotch
Detail #1
Detail #2
Detail #2Detail #1
9.0 ROOF INSTALLATION DETAILS
F_TS0_012R00BRS
PageDwg: Date: February 2012
34
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
The roof panel’s eave overhang dimension is critical as it establishes the location of endlaps and ridge cover attachment points.
The end of the roof panel extends 2” beyond the face of the eave trim unless another dimension is specified on the erection drawings.
If insulation spacer blocks are required, place the blocks on top of the insulation directly over the roof structurals. Spacer blocks are not required at the eave structural.
Position the female edge of the panel over the start clips and position the end of the panel 2” beyond the face of the eave trim.
Tilt the panel as shown so the female seam can be hooked over the start clips. Check that each clip is hooked inside of the seam.
Do not completely remove the eave sealant’s protec-tive paper at this time.
Female Seam
RoofInsulation
Eave Structural
Roof Structural(typ.)
Male Seam
Downslopeend ofRoof Panel
of Box PanelTrimOuter face
Wall Panel
Downslopeend ofRoof Panel
2"
Eave Structural
Eave Sealant'sProtective Paper(peel back only enough
Roof Panel
Roof Panel
Tilt the Roof Panel to hook the female seam onto the Start Clip
Start Clip(typ.)
to set panel)
@ each purlin, Spacer Block
(if required)
PANEL OVERHANG
9.0 ROOF INSTALLATION DETAILS
F_TS0_013R00BRS
PageDwg: Date: February 2012
35
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Verify that the roof panel’s overhang dimension is cor-rect and verify that the roof panel is aligned parallel to the rake line. Raise the leading corner of the panel and remove the protective paper from the eave sealant.
Rotate the panel down to rest on the insulation.
Using the hand seaming tool, close the panel seam over each start clip. For proper operation of the seam-ing tool, refer to the Seaming Instructions section.
Mark the roof panel’s vertical leg at each clip location. This will guide the later installation of rake trim fasteners to ensure they are not installed through the clip tabs.
Outer faceof Eave Trim
Downslopeend ofRoof Panel
Eave Structural
2"
Roof Structural(typ.)
of each Start ClipMark the location
(typ.)Start Clip
Use hand seamer
Roof Panel
Roof Insulation
to close the seamat each start clip
9.0 ROOF INSTALLATION DETAILS
F_TS0_014R00BRS
PageDwg: Date: February 2012
36
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Prepare the corrugation closures by applying flashing sealant along the top surfaces as shown in the above illustration. Remove the protective paper.
Peel back the protective paper from the eave sealant as shown to clear the corrugation closure.
Pick up the corner of the roof panel and place the closure into the panel corrugation and on top of the eave sealant.
Check that the closure is centered to the roof panel’s edge.
Fasten the closure to the eave perimeter plate with a roof fastener installed through the hole in the base of the closure.
Roof Panel
RoofInsulation
Roof Structural
1/4" beyond edge of
Eave Trim
Corrugation Closure(with tape sealant)
Endlap Sealant
Protective Paper
Corrugation
Extend ends of sealant
Flashing Sealant(across topof closure)
Eave Trim
Inside Closure Roof Fastener
Sealant
Perimeter Plate
closure
(peel back to set closure)
Roof Fastener(thru baseof closure)
Lift edge of roof panel to install closure
(typ.)
ProtectivePaper
Closure
CLOSURE SEALANT
CLOSURE ATTACHMENT
9.0 ROOF INSTALLATION DETAILS
F_TS0_015R00BRS
PageDwg: Date: February 2012
37
ET1-1-R0
TS-324™ Roof System Installation Guide
Roof Panel
Roof Structural
Roof Insulation
(typ.)
(compressed underpanel clip)
Clip Fastener Structural@ each RoofPanel Clip
Refer to erection drawingsfor clip fastener type
and quantity
Roof Fasteners
3"
3"
NOTE
Before fastening the roof panel to the eave plate and fastening the leading edge of the panel with the panel clips, check that the panel coverage is correct and the leading edge of the panel is straight and parallel to the rake line.
Fasten the eave end of the panel with (6) roof fasten-ers spaced as shown.
Position the fasteners to penetrate through the center of the sealant, through the eave trim and into the eave plate.
Install roof panel clips to the leading edge of the roof panel at each roof structural. Panel clips are not re-quired at the eave structural.
To install the clips, tilt the clip so that its tab can be hooked over the edge of the roof panel’s male seam. Position the clip’s base so that the clip fasteners can be installed through the holes in the base and into the roof structural, then rotate the clip down into the vertical position.
When fiberglass roof insulation is used, the panel clips normally set on top of the insulation and the insulation is compressed between the clip’s base and the top of the roof structural. In all cases, refer to the erection drawings to determine the required insulation assembly and the relationship of the panel clips to the insulation.
Specific panel clip details are shown on the following page.
9.3 ROOF PANEL INSTALLATION
9.0 ROOF INSTALLATION DETAILS
F_TS0_016R00BRS
PageDwg: Date: February 2012
38
ET1-1-R0
TS-324™ Roof System Installation Guide
Roof Panel
Male Seam
Clip Tab
Clip Base
Roof
Clip Fastener
Roof Panel
Clip Base
Roof Structural
Clip Fastener
Clip's Tab's Hook
Insulation not shown
Clip Tab(must capturepanel's lip)
(must be flushagainst panel)
Structural
for clarity.
CLIP / PANEL ASSEMBLY
Note:
9.3 ROOF PANEL INSTALLATION
Panel clips are available as floating clips or fixed clips and are available in different stand-off heights. Refer to the erection drawings to determine the type of clip and quantity of fasteners required for each roof condition.
Check that the panel clip’s tab is seated tightly around the roof panel’s seam and that the panel clip’s hook has captured the panel’s lip.
Check that the clip’s base is vertical and that the base is set square and firmly over the roof structural.
Panel clip fastener type and quantity vary according to the roof structural material and roof load requirements. Refer to the erection drawings for the required type and quantity of panel clip fasteners.
Check that the clip fasteners are equally spaced through the clip base holes and are securely engaged into roof structural.
CAUTIONFailure to enclose the male lip
in the clip hook and failure to nestthe clip flush against the panel clip
can cause faulty seaming andobjectionable seam appearance.
9.0 ROOF INSTALLATION DETAILS
F_TS0_017R00BRS
PageDwg: Date: February 2012
39
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
With the eave end of the roof panel attached, measure the panel overhang at the purlin (see illustration).
The panel should extend 7” beyond the up-slope web of purlin or centerline of joist.
If the panel overhang is not within this range, call APEC Steel before proceeding with the installation of roof panels. Also reference the erection drawings for prescribed dimensions.
(@ the endlap)Roof Structural
Panel Clip(typ.)
Downslope RoofPanel
Roof Insulation
End ofPanelof Structural
Centerline/Web
Roof Panel
Roof Structural(@ the endlap)
7"
PANEL OVERHANG
9.0 ROOF INSTALLATION DETAILS
F_TS0_018R00BRS
PageDwg: Date: February 2012
40
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Slide the back-up plate under the roof panel, as shown.
The back-up plate must be set over the top of the roof structural. If insulation spacer blocks are used, the back-up plate must be set over the spacer block.
The back-up plate’s tabs must hook over the end of the roof panel.
Use punches to align the holes in the back-up plate with the factory punched holes in the roof panel.
Panel Clip(typ.)
Punch (to align holes Back-up Plate Tabsin panel with holes inback-up plate)
(@ the endlap)Roof Structural
Downslope RoofPanel
Roof Insulation
(must hook over endof panel)
Back-up Plate(set under panel
and on top of spacer block)
9.0 ROOF INSTALLATION DETAILS
F_TS0_019R00BRS
PageDwg: Date: February 2012
41
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
The proper placing of the endlap sealant is critical to the weathertightness of the roof endlaps.
Before installing the endlap sealant, the roof panel’s surface must be wiped clean and dry.
Position the sealant so that its downslope edge is uniformly 1 5/8” from the end of the panel. The seal-ant must be centered over the roof panel’s factory punched holes.
Install a continuous strip of endlap sealant along the end of the roof panel, as shown.
Check that the sealant fully contacts the roof panel’s surface and that it is completely fitted into the panel corners and around the seams.
The sealant’s protective paper helps to retain the seal-ant’s shape during installation and protects the sealant’s surface from damage and contamination. Do not remove the protective paper until immediately before the instal-lation of the up-slope roof panel.
Specific endlap sealant details are shown on the follow-ing page.
1 5/8"
Panel Clip(typ.)
(@ the endlap)Roof Structural
Downslope RoofPanel
Endlap Sealant
InsulationRoof
(centered overpanel holes)
Top edge of sealantbutts back up plate tabs
9.0 ROOF INSTALLATION DETAILS
F_TS0_020R00BRS
PageDwg: Date: February 2012
42
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Cut the endlap sealant to be fitted around the roof panel’s seams, as shown.
Check that the 1/8” ends of the sealant are correctly folded around the roof panel’s edges. Excess seal-ant in the roof panel seams will cause difficult panel assembly. Remove any excess sealant.
After the sealant is correctly positioned, uniformly press the sealant against the roof panel’s surface to ensure adhesion. Do not use excess pressure which can thin the sealant.
ENDLAP SEALANT @ FEMALE RIB
ENDLAP SEALANT @ MALE RIB
1 5/8"
Endlap Sealant
Endlap Sealant
Roof Panel
Roof Panel
Endlap
FemaleRib
1/8" of sealantfolded overedge of panel
1/8" of sealant folded underedge of panel
Sealant
1 5/8"
Roof PanelHole (typ.)
Male Rib
9.0 ROOF INSTALLATION DETAILS
F_TS0_021R00BRS
PageDwg: Date: February 2012
43
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Wipe dry and clean the underside surface of the up-slope roof panel.
Remove the protective paper from the installed endlap sealant.
Position the end of the up-slope roof panel to make a 2” lap over the down-slope roof panel.
At the seams, the end of the up-slope roof panel should butt against the notch on the down-slope roof panel.
Check that the up-slope roof panel will correctly lap over the endlap sealant.
Panel Clip (typ.)
Upslope Roof Panel
Butt end of Panelagainst end of notch to make2" lap
Endlap
Roof Insulation
Roof Structural(@ the endlap)
Downslope Roof Panel
Sealant
Notched End
Roof Panel
9.0 ROOF INSTALLATION DETAILS
F_TS0_022R00BRS
PageDwg: Date: February 2012
44
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Lower the up-slope roof panel to lap onto the down-slope roof panel.
While lowering the up-slope roof panel, bow the end of the panel by pulling up on its center. This will allow the panel to more easily nest into the down-slope panel.
Use punches to align the factory punched holes of the lapping panels. The punch will have to penetrate through the endlap sealant and into the holes in the
back-up plate. Do not disturb the position of the sealant while inserting and removing the punch.
Do not remove the punches from the roof panel holes until after the seam clamps have been installed.
Roof Structural(typ.)
Roof PanelDownslope
End of notch
InsulationRoof
UpslopeRoof Panel
Pull up centerof panel
SealantEndlap
Punch
Panel Clip
(to alignpanel holes)
9.0 ROOF INSTALLATION DETAILS
F_TS0_023R00BRS
PageDwg: Date: February 2012
45
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Use the seam clamps to draw the lapping panel seams together, as shown.
Check that the clamp jaws are correctly aligned to the seam before closing the clamp. Misaligned clamps can distort and damage the roof panel seams.
Slowly close the clamp to allow the sealant to flow between the lapped seams.
With the seam clamps installed, uniformly press down on the up-slope panel to close the panel lap and to ensure adhesion to the endlap sealant.
Hand seam at lap - refer to seaming guide for specific instructions.
Upslope Roof Panel
Punch (to align panel holes)
Roof Panel
Endlap
Seam clamp (centerover the butt jointof the panel ribs)
Seam Clamp (position overthe lapped panel ribs)
DownslopeRoof Panel
Roof Insulation
Panel Clip (typ.) Roof structural(@ the endlap)
Seaming Tool
Roof Panel
Seaming Tool
3"
Endlap EndlapRoof Panel
CLAMPED SEAM
STEP 1 STEP 2
9.0 ROOF INSTALLATION DETAILS
F_TS0_024R01BRS
PageDwg: Date: February 2012
46
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Fastener spacing is the same as required at the eave.
Use a punch to align the factory punched holes in the roof panels and back-up plate.
Install endlap fasteners in the holes at the outside of the panel. Next, install fasteners in the remaining holes.
Check that the endlap fasteners penetrate thru the center of the endlap sealant and are securely engaged into the back-up plate.
Remove seam clamps to complete installation
Specific endlap details are shown on the following page.
Upslope Roof Panel
Endlap
Seam Clamp (position overthe lapped panel ribs)
DownslopeRoof Panel
Roof Insulation
Panel Clip (typ.) Roof structural(@ the endlap)
Endlap Fastener @ each hole pre-punched hole
Upslope Roof Panel
9.0 ROOF INSTALLATION DETAILS
F_TS0_025R00BRS
PageDwg: Date: February 2012
47
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Check that the endlap is correctly assembled as shown.
A panel rib fastener is to be installed after all fasteners have been installed in the flat of the panel
Check that there are no unsealed voids between the lapped panels, especially at the critical corner areas.
Roof PanelDownslope
(typ.)Roof Fastener
Roof PanelUpslope
Back-upPlate
Endlap
Edge of Roof Panel
Sealant
Panel Rib Fastener
9.0 ROOF INSTALLATION DETAILS
F_TS0_026R00BRS
PageDwg: Date: February 2012
48
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
The pigtail sealants must be correctly installed before the next roof panel run can be installed.
Install the eave, endlap and ridge pigtail sealants on the leading edge of the roof panel, as shown.
The pigtail sealants are pieces of endlap sealant cut to the required length.
Refer to the next pages for specific pigtail sealant de-tails.
Eave PigtailSealant
Endlap PigtailSealant
Ridge PigtailSealant
Panel Clip (typ.)
Roof Insulation
Eave Structural
CorrugationClosure
Endlap
Roof Structural (typ.)
Upslope RoofPanel
Downslope RoofPanel
9.0 ROOF INSTALLATION DETAILS
F_TS0_027R00BRS
PageDwg: Date: February 2012
49
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Cut the pigtail sealants to be fitted around the roof panel’s seam, as shown. Use a box knife or scissors to cut. Do not tear or pull.
At the eave, lap 1/4” of the pigtail sealant onto the cor-rugation closure’s sealant. Cut the other end of the pigtail sealant so 1/8” can be folded under the edge of the roof panel. Strip length = 2 1/2” long.
At the ridge, position the pigtail sealant so its edge is 1 5/8” from the end of the roof panel. The sealant must lap over the edge of the roof panel’s notch.
Fold 1/2” of the ridge pigtail sealant under the edge of the roof panel. Cut the other end of the sealant so it sets flush with the bottom edge of the roof panel’s seam. Strip length = 2 1/2” long.
Excess sealant in the seams will cause difficult roof panel assembly. Remove any excess sealant. Cut, do not tear.
After the pigtail sealant is correctly placed, uniformly press the sealant against the panel’s surface to ensure adhesion.
RIDGE PIGTAIL SEALANT DETAIL
EAVE PIGTAIL SEALANT DETAIL
Pigtail Sealant 1/8" of Sealant
Roof Panel
Corrugation 1/4" of Sealantlapped on toClosure Sealant
Closure
folded underedge of Panel
Corrugation
Closure
Pigtail Sealant
of PanelEave End
1/2" of Sealantfolded under
to bottom edgeSealant extends
Roof Panel
Pigtail Sealant
1 5/8"
Ridge end of Panel
Notch
Pigtail Sealant
Sealant
Sealant
edge of RoofPanel
of panel
Closure
Closure
9.0 ROOF INSTALLATION DETAILS
F_TS0_028R00BRS
PageDwg: Date: February 2012
50
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Cut the pigtail sealant to a 3” length and fit around the roof panel’s seam, as shown.
Position the pigtail sealant to lap 1/8” over the downslope end of the roof panel’s notch.
Center the sealant over the roof panel’s seam. Fold the edges of the sealant down over the sides of the seam.
Excess sealant in the seams will cause difficult roof panel assembly. Remove any excess sealant. Cut, do not tear.
After the pigtail sealant is correctly placed, uniformly press the sealant against the panel’s surface to ensure adhesion.
3"
Roof Panel
Upslope Roof Panel
Pigtail Sealant
1/8"
7/8"
Endlap Sealant
End of notch
1/4" of sealant extended down eachside of panel rib
Pigtail Sealant
End ofnotch
Downslope Roof Panel
ENDLAP PIGTAIL SEALANT DETAIL
9.0 ROOF INSTALLATION DETAILS
F_TS0_029R00BRS
PageDwg: Date: February 2012
51
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Repeat previous steps of first panel run and remove the protective paper from the eave sealant. Remove only enough of the protective paper to allow installation of the next roof panel.
If required, place the insulation spacer blocks on top of the insulation directly over the roof structural.
Position the trailing edge of the roof panel over the leading edge of the previously installed roof panel and position the end of the roof panel 2” beyond the face of the eave trim.
Tilt the panel as shown, so the female seam can be hooked over the male seam of the previous roof panel.
Specific roof panel sidelap assembly details are shown on the following page.
Previously installedroof panel
RoofInsulation
previously
Roof Panelinstalled
seam ofMale
SeamFemale
Roof Structural (typ.)Eave Structural
Roof Panel
Panel Clip(typ.)
9.0 ROOF INSTALLATION DETAILS
F_TS0_030R00BRS
PageDwg: Date: February 2012
52
ET1-1-R0
TS-324™ Roof System Installation Guide
STEP 1 STEP 2
STEP 3
1
2
Male Seam
Lift panel to allow female seam to readily rotate over male seam
Lift panel so female hook catches male lip
Female Seam
Tilt panel 90˚ to vertical position
Push hook of female seam under lip of male seam
Engaged SeamCheck that male lip is fully enclosed by the female hook
Rotate panel downto horizontal position
9.3 ROOF PANEL INSTALLATION
It is easier to hook the roof panel seams together if the roof panel is first tilted up to the vertical position.
With the roof panel in the vertical position, align its female seam to slide under the male seam of the previous roof panel.
With the female seam under the male seam, lift up the roof panel so the female seam’s hook catches the lip of the male seam.
While continuing to lift up on the roof panel, rotate the panel down to rest on the insulation.
Be careful not to scrape off the seam sealant during the sidelap assembly.
IMPORTANT: Check that the male and female are fully nested and the female hook has enclosed the male lip along the entire length of the roof panel. If not, the roof panel sidelap must be correctly reas-sembled before installing the next roof panel.
CAUTIONExcessive panel coverage width
can prevent proper sidelapassembly. Check and correct
panel coverage prior to installationof the next panel.
9.0 ROOF INSTALLATION DETAILS
F_TS0_031R00BRS
PageDwg: Date: February 2012
53
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
The most common coverage error is the spreading of the roof panels, especially at the panel ends. This can cause excess panel coverage along the eave, endlaps and ridge.
To correct excess roof panel coverage, use rib clamps to squeeze together the panel ribs, as shown.
The rib clamps can be adjusted and locked so that they will squeeze the panel ribs to provide a consistent coverage width.
If excessive coverage has accumulated over several panel runs, do not try to correct all of the errors at one time. Corrected roof panel coverage must not be greater than 1/8” per panel. Correct accumulated coverage error by making the correction over several panel runs.
Continue process until opposite ends of the structure are reached.
End dams should be installed at the ridge along with the panel.
Rib Clamp
Eave Structural
Endlap
Roof Structural (typ.)
Rib Clamp
Clamp Jaws
Roof Panel
Seam Hook
Roof Panel
Upslope Roof Panel
Downslope RoofPanel
Roof
Seam
Insulation
Adjustment Screw
Locking Nut
(typ.)
RIB CLAMP DETAIL
9.0 ROOF INSTALLATION DETAILS
F_TS0_032R00BRS
PageDwg: Date: February 2012
54
ET1-1-R0
TS-324™ Roof System Installation Guide
9.3 ROOF PANEL INSTALLATION
Caution: To ensure proper fit-up of the sidelap as-sembly, proper seaming, proper fip-up of closures, flashing, curbs, etc., it is important that each panel be held to within the 1/8” panel coverage tolerance and that overall coverage be checked frequently, and any coverage error be corrected before it ac-cumulates.
Coverage must be checked at the eave and ridge and at every endlap.
To avoid accumulation error, the coverage measurement should always be from the rake line or the starting roof panel’s seam.
To avoid measurement error, the measuring tape must be free and taut and must be parallel to the eave line or ridge line.
Improper coverage will cause difficulty in seaming.
PANEL COVERAGE MEASUREMENT
CHECKING PANEL COVERAGE
Note:
(typ.)Roof Structural
Endlap
at eaveMeasuring Tape
Measuring Tapeat ridgeIntermediate
Starter Panel MeasuringTape
(typ.)Roof Panel
Read measurement atthis edge of panel seam
Hold or clampend of tape tightagainst face of
Hold measurement parallelto eave, endlap or ridge.
Measuring Tapeat endlap
Starting RoofPanel
panel seam
Roof Panels
9.0 ROOF INSTALLATION DETAILS
F_TS0_033R00BRS
PageDwg: Date: February 2012
55
ET1-1-R0
TS-324™ Roof System Installation Guide
9.4 END DAM INSTALLATION
Metal end dams are used to close the ends of the roof panels at the ridge, high eave and high eave transition conditions.
The details in this section will show roof panel preparation requirements and installation of the end dams.
Rake Angle
Starting RoofPanel
Panel (typ.)Intermediate Roof
End Dam(typ.)
Termination
Termination
Roof Panel
End Dam
Termination Zee
9.0 ROOF INSTALLATION DETAILS
F_TS0_034R00BRS
PageDwg: Date: February 2012
56
ET1-1-R0
TS-324™ Roof System Installation Guide
9.4 END DAM INSTALLATION
The end dams should be installed before roof panel runs are completed. Installation of the end dams helps maintain the correct roof panel coverage at the ridge. If the end dams are installed after the roof panels are in place, roof panel coverage error may prevent proper installation of the end dams.
Check the alignment of the roof notches along the ridge. If the notches are staggered more than 1/4”, use a chalk line to establish a straight notch line. Position the chalk line so no notch extends below the line.
Using the end of the factory notch (or chalk marks) as a guide, field cut the additional notching in both male and female portions of the seam as shown.
Hand seam 16” of uphill panel end before installing tape sealant and end dam, to accomodate motor seamer - Refer to seaming guide for specific instructions.
NOTCH FOR RIDGE CLOSURE
MARKING RIDGE CLOSURE LINE
STEP 1
STEP 2
Ridge end ofRoof Panel
Roof Panel
Chalk Mark
Field cut off maleand female panelribs, to the chalk mark
Roof Panels
Ridge end of Roof Panels
2"
Panel Notch(typ.)
Chalk Line
(typ.)Chalk Mark
2"
1/8"
Seaming Tool
Seaming Tool
end of Roof PanelEave or Ridge
Eave or Ridgeend of Roof Panel
6"
9.0 ROOF INSTALLATION DETAILS
F_TS0_035R01BRS
PageDwg: Date: February 2012
57
ET1-1-R0
9.4 END DAM INSTALLATION
Slide the back-up plate under the roof panel, as shown.
The back-up plate must be set over the top of the roof structural. If insulation spacer blocks are used, the back-up plate must be set over the spacer block.
If the ridge purlin is located too far down slope for the back-up plate to rest on the purlin or spacer block, use
a clamp to hold the back-up plate in position until after the fasteners are installed.
The back-up plate’s tabs must hook over the end of the roof panel.
Use punches to align the holes in the back-up plate with the factory punched holes in the roof panel.
Punch (to align holes in panelwith holes in back-up plate)
Ridge end ofRoof Panels
Roof Panel
Back-Up Plate Tabs
Back-Up Plate
RoofInsulation
Ridge RoofStructural
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_036R00BRS
PageDwg: Date: February 2012
58
ET1-1-R0
9.4 END DAM INSTALLATION
Before installing the endlap sealant, the roof panel’s surface must be wiped clean and dry.
Install a continuous strip of endlap sealant along the end of the roof panel, as shown.
Position the sealant so that its downslope edge is uniformly 1 5/8” from the end of the panel. The seal-ant must be centered over the roof panel’s factory punched holes.
Be sure to check that the sealant fully contacts the roof panel’s surface and that it is completely fitted into the panel corners and around the seams
Cut a 2 1/2” strip of endlap sealant and install as the pigtail sealant, as shown.
Specific endlap sealant details are shown on the following page.
Pigtail Sealant
Remove protectivepaper.
Endlap Sealant
Roof Panel Roof Insulation
Ridge RoofStructural
(centered over panel holes)
PigtailSealant
Panel Holes(typ.)
1 5/8"
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_037R00BRS
PageDwg: Date: February 2012
59
ET1-1-R0
9.4 END DAM INSTALLATION
The correct installation of the ridge sealant is critical to the weather resistance of the roof system.
Be sure to verify that the sealant is installed as shown above before installing end dams.
After the sealant is correctly positioned, uniformly press the sealant against the roof panel’s surface to ensure adhesion. Do not use excess pressure, which can thin the sealant.
ENDLAP SEALANT @ RIDGE PIGTAIL SEALANT @ RIDGE
Roof Panel
Roof Panel
2 1/2" Pigtail Sealant
over seamSealant wrapped
End of Notch
Pigtail Sealant
Sealant wrapped
of Roof PanelRidge end
1/8" of Sealantextended down
under seam
Endlap Sealant
1/4" of Sealantfolded over
Endlap Sealantedge of seam
1 5/8"
Panel Hole(typ.)
Make Sure Sealant Makes Contact
1 5/8"
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_038R00BRS
PageDwg: Date: February 2012
60
ET1-1-R0
9.4 END DAM INSTALLATION
Wipe dry and clean the underside surface of the end dam flanges.
Remove the protective paper from the installed ridge sealant.
Position the end dam so its bottom flange is turned up-slope and its top flange is downslope.
Position the end dam’s bottom flange directly over the ridge sealant and use punches to align the holes in the end dam with the factory punched holes in the roof panel and back-up plate.
Be careful not to displace or damage the sealant while installing the end dam and punches.
Roof Panel
Top flange(must be ondownhill side)
End Dam
EndlapSealant
Ridge RoofStructural
End Dam
Punch (to align holes in closure with holes in
Roof Insulation
panel and back-up plate)
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_039R00BRS
PageDwg: Date: February 2012
61
ET1-1-R0
9.4 END DAM INSTALLATION
While the matching holes are aligned by the punches, uniformly press the end dam into the ridge sealant to ensure adhesion. Use a clamp to hold the assembly together while installing the fasteners.
Install endlap fasteners through the holes in the end dam’s bottom flange.
Check that the fasteners penetrate through the center of the ridge sealant and are securely engaged into the back-up plate.
Check that the face of the end dam is perpendicular to
the roof panel and aligned with the previously installed end dams. If not, push the top of the end dam to the correct position.
Install a self-drilling fastener through the hole at the top of the end dam, through the roof panel seam and into the hole in the opposite end dam.
Important: Overtightening this fastener will squeeze the roof panel sidelap assembly together and may affect the roof panel’s coverage width. Carefully tighten the fastener, only as necessary, to maintain the correct panel width.
END DAM ALIGNMENT
END DAM ATTACHMENT
Roof Panel
Back-up PlateRoof Panel
End Dam
Endlap Sealant
Endlap Fastener@ each hole in End Dam
Endlap Sealant
Back-up Plate
Clamp
End Dam
Punch (to align holes in end dam with holes in panel and back-up plate)
RoofFastener
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_040R00BRS
PageDwg: Date: February 2012
62
ET1-1-R0
9.4 END DAM INSTALLATION
Verify that the end dam is correctly assembled, as shown.
Check that there are no un-sealed voids between the roof panel and the end dam, especially in the critical areas around the roof panel ribs and seams.
Back-up Plate
Roof Panel (typ.)
Endlap Sealant
Pigtail Sealant
Face of End Dam
Edge of Endlap Sealant
End Dam
Top flange of End Dam
Endlap Fastener (typ.)
End Dam
Ridge end of Roof Panel
Bottom flangeof End Dam
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_041R01BRS
PageDwg: Date: February 2012
63
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
The details in this section show the installation of the termination roof panel and the termination zee.
The details show the termination roof panel installed at the finish rake. The installation of the termination panel at the starting rake is similar.
Rake Angle
(typ.)Roof Panel
Termination Roof
Perimeter Plate
Termination Zee
Panel
9.0 ROOF INSTALLATION DETAILS
F_TS0_042R00BRS
PageDwg: Date: February 2012
64
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
Refer to the erection drawings to determine which po-sition to place the rake perimeter plate. The position of the rake perimeter plate will depend on the location of the termination roof panel, as shown on the above illustrations.
If the leading edge of the panel extends 4” or more beyond the face of the rake angle, install the rake plate in the standard position.
If the leading edge of the panel extends less than 4” beyond the face of the rake angle, install the rake plate in the alternate position.
If the rake condition requires transition flashing, refer to the following page.
Shoulder Fastener
Shoulder Fastener
STANDARD RAKE PLATE POSITION
ALTERNATE RAKE PLATE POSITION
Perimeter Plate
Roof Panel
Perimeter PlateRoof Panel
Termination
Rake Angle
Field cut excess Roof Panel
4" max.
4" min.
Align edge of Rake Plate flush with face of Rake Angle if straight. Otherwise, use chalk line or straight line
Align step of Rake Plate flush with face of Rake Angle if straight. Otherwise, use chalk line or straight line.
Termination Roof Panel
Rake Angle
Roof Panel
9.0 ROOF INSTALLATION DETAILS
F_TS0_43R00BRS
PageDwg: Date: February 2012
65
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
It is important that the rake perimeter plate is installed in a straight line, square with the eave.
If the rake angles have been installed straight and true, the edge of the rake angle can be used to align the rake perimeter plate.
If the rake angle is not true and square, a chalkline should be used to guide the installation of the rake perimeter plate.
Start the end of the rake perimeter plate flush with the outer edge of the eave perimeter plate. Notch the bottom flange of the rake plate to clear the eave perimeter plate.
Secure the starting end of the rake perimeter plate to the rake angle with a panel clip fastener in the rake perimeter plate’s first slot.
To allow for expansion/contraction movement, secure the rest of the rake perimeter plate run to the rake angle with shoulder fasteners, spaced as shown. Install the shoulder fasteners in the center of the slots.
Perimeter Plate
RakeAngle
Panel Clip Fastener @ first slot from Eave
Notch Perimeter Plate
Shoulder Fasteners@ 24" O.C.
PerimeterPlate
StructuralEave
Roof Structural(typ.)
9.0 ROOF INSTALLATION DETAILS
F_TS0_044R00BRS
PageDwg: Date: February 2012
66
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
Butt join the ends of the rake perimeter plate and angle. Install the shoulder fasteners in the slots on either side of the butt joints.
Field cut the last rake perimeter plate two inches (2”) from the ridge line or high eave line.
Rake Angle
Butt join Perimeter Plates
Perimeter Plate
Ridge3"
Shoulder Fasteners@ 24" O.C.
Field cut end of Perimeter Plate
Roof Structurals(typ.)
(min.)
9.0 ROOF INSTALLATION DETAILS
F_TS0_045R02BRS
PageDwg: Date: February 2012
67
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
Field cut the termination roof panel to the required width. The cut edge of the panel should extend 1” beyond the outer edge of the rake perimeter plate’s top flange.
Along the cut edge of the termination roof panel, wipe the underside clean and dry.
Remove the protective paper from the eave sealant and rake plate sealant.
Install the termination panel into position, as shown.
Install the eave fasteners and temporarily clamp the edge of the panel to the rake perimeter plate.
Clamp
Primeter Plate
Roof Panel
Roof Fastener
Rake Angle
Field cut edge of Finish Panel
Termination RoofPanel
Perimeter Plate
9.0 ROOF INSTALLATION DETAILS
F_TS0_047R00BRS
PageDwg: Date: February 2012
68
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
Along the cut edge of the termination roof panel, wipe the top surface clean and dry.
Install endlap sealant continuous along the edge of the termination roof panel, as shown.
The rake closure sealant must be positioned directly over the rake perimeter plate’s top flange. Layout the sealant location on the panel’s top surface with a chalk line as shown. Align the chalk line with the rake plate’s step. No red chalk.
Position the edge of the sealant on the chalk line. Start and finish the ends of the sealant flush with the ends of the roof panel.
Check the entire length of the sealant to ensure that it is correctly positioned and that there are no voids or thinned areas.
After the sealant has been correctly installed, lightly press the sealant against the roof panel to ensure adhesion. Do not use excess pressure which can thin the sealant.
Perimeter Plate
Step of
Eave Strut
Roof Panel
Finish Roof Panel
Chalk Line-NEVER RED !!
Perimeter Plate
Perimeter Plate
Step of
Endlap Sealant (Set edge of sealant flush with chalk line)
Edge of Roof Panel
Roof Structural (typ.)
Rake AngleEdge of Sealant
9.0 ROOF INSTALLATION DETAILS
F_TS0_048R00BRS
PageDwg: Date: February 2012
69
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
The termination zee must be installed from ridge-to-eave, to provide for watershed at the termination zee splices.
Install the termination zee on top of the sealant, as shown.
Position the zee so its bottom flange is turned outward and its inside edge is flush with the inside edge of the sealant. Position the end of the zee flush with the uphill end of the roof panel.
Uniformly press the zee against the sealant to ensure adhesion.
Attach the termination zee with roof fasteners at 6” spac-ing. Check that the fasteners penetrate the center of the sealant and securely engage the rake plate.
Rake Angle
Roof Panel
Ridge Roof
Ridge end of Roof Panel
Start end of Zee flush with uphill end of roof panel
Termination Zee
Roof Fasteners @ 6" O.C.
Endlap Sealant
Install termination zee from ridge to eave to provide watershed at zee splices
Termination Roof Panel
Structural
Perimeter Plate
IMPORTANT
9.0 ROOF INSTALLATION DETAILS
F_TS0_049R00BRS
PageDwg: Date: February 2012
70
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
Apply two 3/16” beads of tube sealant along the downslope end of the termination zee, as shown.
Position the next downhill zee, overlapping the previ-ously installed zee by 2”.
Clamp the lapped zee while installing the fasteners.
Attach the next zee with roof fasteners. Install the first fastener through the lapped bottom flanges.
Install a 1/8” pop rivet through the lapped upper flang-es.
Position the last zee so its down slope end is flush with the eave end of the roof panel. Then, cut the up-slope end for a 2” lap at the splice.
TERMINATION ZEE AT EAVE
TERMINATION ZEE SPLICE
Eave end ofRoof Panel
Termination
Termination Zee
Termination Zee
2"
Water Flow
Perimeter Plate
Lap Zee 2"
1/2"
1/8" dia.
1/8"
Field cut uphill end of Zee to required length at splice
Finish end of Zee (flush with end of roof panel)
Position Zee so exposed end is factory cut
Perimeter Plate
Termination Roof Panel
(2) 3/16" dia. beads Tube Sealant
Termination Zee
Roof Fastener
Endlap Sealant
Blind Rivet
Roof Panel
Pigtail
9.0 ROOF INSTALLATION DETAILS
F_TS0_050R00BRS
PageDwg: Date: February 2012
71
ET1-1-R0
TS-324™ Roof System Installation Guide
9.5 TERMINATION PANEL INSTALLATION
An end dam must be field modified to fit between the roof panel rib and the termination zee.
Install the ridge sealant to extend up the face of the termination zee, as shown.
Field modify the end dam and install, as shown.
End Dam
2"
Endlap Sealant
Termination Zee
Roof Panel
1/8" dia. Blind RivetRoof Panel
Termination Zee
End Dam
Endlap Fasteners at holes in End Dam
Lap Fastener
Termination
Termination
Field cut and tab end of End Dam to fit Termination Zee
Field notch Termination Zee as shown
Extend endlap sealant up inside face of Termination Zee
Roof Panel
Roof Panel
3/16" dia. bead tube sealant pigtail
9.0 ROOF INSTALLATION DETAILS
F_TS0_051R00BRS
PageDwg: Date: February 2012
72
ET1-1-R0
TS-324™ Roof System Installation Guide
9.6 RAKE TRIM INSTALLATION
The details in this section show the installation of the rake trim, peak box and end caps.
These details show the rake trim at a termination roof panel condition. The details at a starting roof panel condition are similar.
End Dams (typ.)
Roof Panels
Rake Trim
End Cap
Rake Trim
Slide Trim
Peak Box
9.0 ROOF INSTALLATION DETAILS
F_TS0_052R00BRS
PageDwg: Date: February 2012
73
ET1-1-R0
TS-324™ Roof System Installation Guide
9.6 RAKE TRIM INSTALLATION
Install the rake trim from eave to ridge, to provide for watershed at the splices.
Install flashing sealant continuous along the top flange of the termination zee (or roof panel seam).
Start the down-slope end of the rake trim flush with the end of the roof panel.
Check that the rake trim is properly aligned with the face of the wall panel.
Fasten the rake trim to the termination zee with lap fasteners at 12” spacing, as shown. Be sure fasteners do not penetrate the start clip tabs and are 2” from clip ends.
Be sure to check that the fasteners penetrate the center of the sealant and securely engage the termination zee (or roof panel seam).
Eave Trim
Eave Trim
Start or Termination Roof Panel
Termination Zee(or roof panel seam)
Sealant
Lap Fastener@ 12" O.C.
ProtectivePaper
Sealant
Termination ZeeStart or Termination Roof Panel
Rake Trim
12"
Starting End of Rake Trim(flush with end of roof panel and termination zee)
9.0 ROOF INSTALLATION DETAILS
F_TS0_053R00BRS
PageDwg: Date: February 2012
74
ET1-1-R0
TS-324™ Roof System Installation Guide
9.6 RAKE TRIM INSTALLATION
Assemble rake trim splices with tube sealant and rivets, as shown.
Bend or notch the rake trim’s lip to clear the top flange of the end dam.
At the ridge, field cut the uphill end of the rake trim 2” back from the center line of the ridge.
At a high eave transition, field cut the end of the rake trim as required for a weathertight joint with the adjacent construction.
RAKE TRIM @ RIDGE
RAKE TRIM SPLICE
End Dam
Rake Trim
2"
Rake Trim
Finish end ofRake Trim
Upslope
1 1/2"
3/16" Dia.Pigtail
1/2"
Lap Fastener @ Panel Seam or Termination Zee(or roof panel seam)
Downslope Rake Trim
3/16" Dia. Bead Tube Sealant
Roof Panel Rib or Termination Zee(or roof panel seam)
Bend up or notch Rake Trim to clear End Dam
Tape Sealant
Downslope Rake Trim
Secure lap with 1/8"dia. Blind Rivets
so exposed edgePosition Rake Trim
is factory cut
Flashing Sealant
9.0 ROOF INSTALLATION DETAILS
F_TS0_054R00BRS
PageDwg: Date: February 2012
75
ET1-1-R0
TS-324™ Roof System Installation Guide
9.6 RAKE TRIM INSTALLATION
If the rake trim run is 50’ or less, the bottom edge of the rake trim can be attached directly to the wall with wall fasteners, as shown.
If the rake trim run exceeds 50’, the bottom edge of the rake trim must be secured with the slide trim to allow for roof expansion/contraction.
Install the slide trim continuous along the bottom edge of the rake trim, as shown.
In all cases, the bottom edge of the rake trim must be installed straight and parallel to the roof line. Use a chalk line to guide the alignment of the rake trim’s bot-tom edge.
FIXED ATTACHMENT
IMPORTANT
SLIDING ATTACHMENT(50' or less) (exceeds 50')
Rake Trim
Wall Fastener@ 12" o.c. (max.)
Slide Trim
Wall Fastener@ 12" o.c. (max.)
Eave Trim
Wall
Corner Trim Starting end of Slide Trim(flush with face of corner trim)
Slide Trim
Rake Trim
For rake lengths (eave to ridge)exceeding 50', a sliding type attachment of the rake trim
to wall is required.
Rake Trim
9.0 ROOF INSTALLATION DETAILS
F_TS0_055R00BRS
PageDwg: Date: February 2012
76
ET1-1-R0
TS-324™ Roof System Installation Guide
9.6 RAKE TRIM INSTALLATION
If the rake trim does not require the slide trim for expansion/contraction, the peak box can be installed with tube sealant and rivets, in the same manner as a splice.
If the rake trim requires the slide trim for expansion/ contraction, the peak box must be installed as shown in the above details.
Secure the top of the peak box by clinching its top edge around the top edge of the rake trim.
Secure the bottom edge of the peak box with the slide trim.
NOTE
Lap the sealants
End Dam
Rake Trim
Peak Box
Rake Trim
Clinch
Peak Box
Clinch
1/4" dia. Bead Tube Sealant
Starting or TerminationRoof Panel
Starting or Termination Roof Panel
If slide trim is not required, attach Peak Box to Rake Trim with 1/8" dia. blind rivets.
Slide Trim
9.0 ROOF INSTALLATION DETAILS
F_TS0_056R00BRS
PageDwg: Date: February 2012
77
ET1-1-R0
9.6 RAKE TRIM INSTALLATION
The rake trim end cap is only required for roof applica-tions without eave gutter.
The end cap must be field cut and a tab bent, to fit the termination zee or starting roof panel, as shown.
Install the end cap with tube sealant and rivets in the same manner as a splice.
NOTE
END CAP DETAIL
Eave Trim
Rake TrimEnd Cap
Termination
Eave Trim
Starting or
Rake Trim
Rake TrimEnd Cap
RakeTrim
1/2"
Rake Trim End Cap is not required when eave has Eave Gutter
or Eave Box Trim
Notch to clear Roof Panel
Secure with 1/8" dia. Blind Rivets
Set End Cap flush with end of Rake Trim
Roof Panel
Field Cut and bend tab to fit terminationzee or starting roof panel
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_057R00BRS
PageDwg: Date: February 2012
78
ET1-1-R0
9.7 RAKE TRANSITION INSTALLATION
The details in this section show the installation of the rake transition flashing.
Counter flashing details are not shown. Refer to the erection drawings for the required counter flashing.
In all cases, verify that counter flashing will:
1. Allow expansion/contraction of the transition flashing.
2. Restrain the transition flashing during roof live loads and wind loads.
3. Provide a weather resistant seal between the transition flashing and the wall.
Peak Box
Rake Trim
TransitionFlashing
FlashingCounter
End Dam (typ.)
EndCap
End Cap
(typ.)Roof Panel
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_058R00BRS
PageDwg: Date: February 2012
79
ET1-1-R0
9.7 RAKE TRANSITION INSTALLATION
For rake to wall transition conditions, position rake perimeter plate as shown.
Refer to the erection drawings for the required spacing of the rake perimeter plate from the face of the rake angle.
High Wall or Parapet Wall Line
Perimeter PlateRoof Panel
Termination Roof Panel
Rake Angle
Field cut excess Roof Panel
RAKE PERIMETER PLATE AT HIGH WALL
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_059R00BRS
PageDwg: Date: February 2012
80
ET1-1-R0
9.7 RAKE TRANSITION INSTALLATION
Install the transition flashing from eave to ridge to provide for watershed at the splices.
Install flashing sealant continuous along the top and bottom flange of the termination zee. Make sure bottom flange is turned to the inside of the detail.
Start the downslope end of the transition flash flush with the end of the roof panel and position the back leg flush with the rake angle or wall construction.
Be sure to raise the vertical leg of the transition flashing to provide a positive pitch and ensure watershed.
Attach the flashing to the termination zee with lap fasten-ers at 12” spacing as shown.
Check that the fasteners penetrate the center of the seal-ant and securely engage the termination zee.
Eave Trim
WallEave Strut
1"
Transition Flashing
Flashing Sealant
Termination Zee
Pitch
@ 12" o.c.Lap Fastener
Rake Angle
Paper
TerminationPanel
Protective
Starting end of Transition Flashing(flush with end of roof panel and termination zee)
Roof Structural (typ.)
See Erection DrawingsFor Counter Flash Details
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_060R00BRS
PageDwg: Date: February 2012
81
ET1-1-R0
9.7 RAKE TRANSITION INSTALLATION
Assemble transition flashing splices with flashing seal-ant and lap fasteners, as shown. Wipe dry and clean the lapping surfaces of the flashing.
Bend or notch the flashing’s lip to clear the top flange of the end dam.
At the ridge, field cut the end of the flashing 2” away from the center line of the ridge.
At a high eave transition, field cut the end of the flash-ing as required for a weathertight joint with the adjacent construction.
TRANSITION FLASHING SPLICE
TRANSITION FLASH AT RIDGE
TransitionFlashing Pitch
Pitch
RakeAngle
Flashing
FlashingTransition
flashing to clearBend up or notch
End Dam
2"
End Dam
Transition FlashingFinish end of
Flashing Sealant
Protective Paper
Pitch
1/8" dia. rivets@ vertical surface
so exposed edgePosition Flashing
is factory cut
2"
Transition Flashing
1/2"
Sealant
AngleRake
@ horizontalLap Fasteners
surface
FlashingSealant
Pigtail Sealant
Roof S
lope
(cut 2" back from ridge ?)
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_061R00BRS
PageDwg: Date: February 2012
82
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
The details in this section show the installation of the ridge cover.
The ridge cover can start or finish at either a rake trim condition or a rake transition condition.
Counter Flashing
Transition Flashing
Rake Trim
Peak Box
Ridge End Cap
Ridge Flashing
Roof Panel (typ.)
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_062R00BRS
PageDwg: Date: February 2012
83
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
Position the end cap so its face is flush with the face of the rake trim.
Fasten the end cap to the rake trim with (2) rivets, as shown.
Install flashing sealant on top of the end cap, as shown. Align the edge of the sealant flush with face of the end cap and extend the sealant to align with the end dams.Install flashing sealant continuous along the top flange of the end dams. Lap the end of the sealant over the end cap sealant.
END CAP DETAIL
Note: Opposite slope roof panels omitted for clarity.
Roof Panel
Lap the sealants
Flashing Sealant
(@ each sideBlind Rivet1/8" dia.
of End Cap)
Rake Trim
Flashing Sealant
End Cap
End Dam
Remove Paper
Field Flatten AngledLeg of Gable Flash
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_063R00BRS
PageDwg: Date: February 2012
84
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
Install the ridge cover to span across the opposing end dams run, as shown.
Position the end of the ridge cover flush with the face of the end cap.
Align the center of the ridge cover over the ridge centerline. Use a string line to ensure a straight ridge cover installation.
Fasten the ridge cover to the end dams with lap fasten-ers, spaced as shown. Check that the fasteners pen-etrate the center of the sealant and securely engage the termination zee.
Important: To provide watershed, the ridge cover must have a positive pitch, even during roof panel contraction.
To increase the ridge cover’s pitch, first fasten only one edge of the ridge cover, then push on the opposite edge of the ridge cover to deflect its center upward. Hold it in this position with clamps, while fastening the other edge.
Align screws at each panel riband � of pan.
Roof Panel
Rake Trim
End of Ridge Cover(flush with face of
Lap Fasteners(typ.) Position Ridge Cover
so exposed end isfactory cut
Ridge Cover
Lap Fasteners @ 6" o.c.
Protective
1/2"
end cap)
Clamp
Tape Sealant
Note: Opposite slope roof panels omitted for clarity.
End Dam
Paper
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_064R00BRS
PageDwg: Date: February 2012
85
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
Position the ridge endcap on top of the transition flashing so that it is 2” from the 90 degree bend. Flashing sealant is required below the endcap on top of the transition flashing.
Install flashing sealant on top of the endcap as shown. Position the edge of the sealant flush against the face
of the transition flashing and extend the ends of the sealant to align with the end dams.
Install flashing sealant continuous along the top flange of the end dams. Lap the end of the sealant over the endcap.
Roof Panel
Tape Sealant
RakeAngle
End Dam
Note: Opposite slope roof panels omitted for clarity.
Flashing SealantRidge Endcap
Lap transition trimat ridge.
FlashingTransition
Lap the sealants
2"
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_065R00BRS
PageDwg: Date: February 2012
86
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
Install the ridge cover to span across the opposing end dam runs, as shown.
Position the end of the ridge cover flush against the face of the Ridge Endcap.
Align the center of the ridge cover over the ridge centerline. Use a string line to ensure a straight ridge cover installation.
Fasten the ridge cover to the end dams with lap fasten-ers, spaced as shown. Check that the fasteners pen-etrate the center of the sealant and securely engage the termination zee.
Important: To provide watershed, the ridge cover must have a positive pitch, even during roof panel contraction.
To increase the ridge cover’s pitch, first fasten only one edge of the ridge cover, then push on the opposite edge of the ridge cover to deflect its center upward. Hold it in this position with clamps, while fastening the other edge.
Lap Fasteners atEach Panel Rib
Roof Panel
Ridge Cover
ProtectivePaper
End Dam
Clamp
RakeAngle
TransitionFlashing
Note: Opposite slope roofpanels omitted for clarity.
Flashing Sealant
Lap Fasteners(typ.)
Butt end of Ridge flashing flush against ridge endcap below
2"
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_066R00BRS
PageDwg: Date: February 2012
87
ET1-1-R0
9.8 RIDGE COVER INSTALLATION
Assemble the ridge cover splices with flashing sealant and lap fasteners, as shown.
Important: The splice fasteners must be installed carefully to avoid downward deflection and buckling of the ridge cover ends.
Ridge Cover
Flashing Sealant
(2) 1/4" dia. beadsTube Sealant
Flashing Sealant
Lap Fasteners
End Dam
Position lap so exposededge is factory cut
Ridge Cover
End Dam
panels omitted for clarity.Note: Opposite slope roof
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_067R00BRS
PageDwg: Date: February 2012
88
ET1-1-R0
9.9 HIGH EAVE TRANSITION INSTALLATION
The details in this section show the installation of high eave transition flashing.
The transition flashing can start or finish at either a rake trim condition or a rake transition condition.
In all cases, verify that counter flashing will:
1. Restrain the transition flashing during roof live loads and wind loads.
2. Provide a weather resistant seal between the transi-tion flashing and the wall.
Transition Flashing
Counter Flashing
Rake Trim
TransitionFlashing
Roof Panel (typ.)
Counter Flashing
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_068R00BRS
PageDwg: Date: February 2012
89
ET1-1-R0
9.9 HIGH EAVE TRANSITION INSTALLATION
Install end slip cap to wall using gable trim to locate position
Field cut the end cap or end plate to fit, as shown.
Position the transition end plate so its face is flush with the face of the rake trim or transition flashing.
Fasten the end cap or end plate with rivets, as shown.
Install flashing sealant on top of the end cap or end plate, as shown. Align the edge of the sealant flush with face of the end cap or transition flashing and extend the sealant to align with the end dams.
Install flashing sealant continuous along the top flange of the end dams. Lap the end of the sealant over the end cap sealant.
END CAP @ RAKE TRIM
END PLATE @ RAKE TRANSITION
PanelRoof
Rake Trim
Transition End Cap
Wall or
RoofPanel
End Dam
Lap the sealants
Parapet
Flashing Sealant
Transition End Plate
Flashing Sealant
Blind Rivet1/8" dia.
3/16" bead of TubeSealant under edgeof End Plate
Flashing
Flashing Sealant
Sealant
1/8" dia. Blind Rivet
Lap the sealants
End DamFlashingTransition
Field Trim
End Slip Cap
END CAP
END SLIP CAP
Attach toHigh Wall
Field Flatten AngledLeg of Transition Flash
2" Min. Slip Joint
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_069R00BRS
PageDwg: Date: February 2012
90
ET1-1-R0
9.9 HIGH EAVE TRANSITION INSTALLATION
Position the end of the flashing flush with the face of the end cap or rake transition flashing and position the back leg flush with the wall construction.
Check that the flashing is set at a positive pitch to ensure watershed.
Fasten the transition flashing to the end dams with lap fasteners, spaced at 6” on centers. Check that the fasteners penetrate the center of the sealant and securely engage the termination zee.
LapFasteners
TransitionFlashing
Clamp
Rake TrimRoof Panel
Lap Fasteners@ 6" o.c.
Flashing Sealant
Protective Paper
Butt end of Transition
Transition End Plate
TransitionFlashing
Flashing flush against
End of TransitionFlashing (flush withface of end cap)
TransitionEnd Cap
1/4" dia. bead ofTube Sealant
Lap Fasteners
End PlateTransition Flashing
Clamp
End Dam
INSTALLATION @ RAKE TRIM
INSTALLATION @ RAKE TRANSITION
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_070R00BRS
PageDwg: Date: February 2012
91
ET1-1-R0
9.9 HIGH EAVE TRANSITION INSTALLATION
Assemble the transition flashing splices with flashing sealant and lap asteners, as shown.
Important: The splice fasteners must be installed carefully to avoid downward deflection and buckling of the flashing ends.
Roof Panel
Roof Panel
Transition
Lap Fasteners
Flashing
TransitionFlashing
1/8" dia. Blind Rivet
1/2"
Pitch
End Dam
Pigtail Sealant
Flashing Sealant
Flashing Sealant
FlashingTransition
Protective Paper
2"
2" Lap
End Dam
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_071R00BRS
PageDwg: Date: February 2012
92
ET1-1-R0
9.10 EAVE GUTTER INSTALLATION
The details in this section show assembly and instal-lation of eave gutter.
Assembly of the gutter should be accomplished with care given to the final appearance. The appearance of the gutter will have a critical effect on the appear-ance of the project.
Determine which direction the building is most often viewed. Install gutter laps facing away from the most often viewed direction.
Proper downspouts are necessary to prevent gutter over-flow and roof flooding. Refer to the erection drawings to determine the required downspout size and spacing.
Rake Trim
Corner Box
Eave Gutter
Counter Flashing
Transition Flashing
Peak Box
Ridge End Cap
Ridge Flashing
Ridge End Plate
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_072R00BRS
PageDwg: Date: February 2012
93
ET1-1-R0
9.10 EAVE GUTTER INSTALLATION
Layout the gutter assemblies in manageable lengths (30’ to 40’) before raising to the roof.
Start and finish the gutter ends flush with the exterior face of the rake walls.
Assemble the gutter end caps and splices with tube seal-ant and rivets, as shown on the above details.
Erection Tip: Assemble lengths on the ground, then with proper man power, slide the length under the eave and temporary clamp to eave overhang for fastening to panel.
EAVE GUTTER END CAP
EAVE GUTTER SPLICE
End CapGutter
At finish endfield cut Gutterto required length
Tube SealantDia. Beads(2) 3/16"
1/8" dia.Blind Rivets
GutterEnd Cap
Gutter
Secure with
1/2"
Gutter
1/2"
dia. beads(2) 3/16"
Tube Sealant
Gutter
1/2"
Gutter
1/8" dia. Rivets@ front, bottom& back of Gutter
2"
so exposed edgePosition Gutter
is factory cut
2"
notchField cut
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_073R00BRS
PageDwg: Date: February 2012
94
ET1-1-R0
9.10 EAVE GUTTER INSTALLATION
Lift the gutter assembly into position under the edge of the roof panels and temporarily clamp the back flange of the gutter to the roof panel.
Position the back face of the gutter assembly flush against the eave trim and position its ends flush with the exterior face of the rake wall.
Fasten the gutter’s back flange to the underside of the roof panel with lap fasteners.
Check that the lap fasteners are securely engaged into the gutter’s back flange.
Apply strips of flashing sealant to the inside and along the length of the gutter supports. Position the sealant over the factory punched holes in the support.
Install the gutter supports and fasten to the roof panel with lap fasteners. Refer to erection drawings for the required gutter support spacing.
Align the outer edge of the gutter straight and level. Use a string line to ensure that the gutter is straight.
Fasten the gutter’s outer flange to the end of the gutter support with a rivet, as shown.
Rake WallClamp
NOTE
Wall
Gutter Assembly
End of GutterAssembly
Roof Panel (typ.)
Screws @ 12" o.c.Gutter Support
SupportGutter
Lap Fasteners(4) per support
Refer to shop drawings for Gutter Support spacing
1/8" dia. rivet
Apply mastic between paneland gutter supprt clip
Note: Gutter is not to be attached to panel with pre-punched holes.
Plate ScrewsPanel to Perimeter
Masticstrip
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_074R00BRS
PageDwg: Date: February 2012
95
ET1-1-R0
9.10 EAVE GUTTER INSTALLATION
Install the corner boxes as shown.
Install bird stop on top of gutter end stop and align with termination zee or panel hem.
Position the corner box to lap over the face of the gut-ter and inside of the rake trim.
Carefully align the corner box so it is straight and level with the gutter and the rake trim.
Attach the corner box with tube sealant and rivets, as shown.
RakeTrim
inside Rake TrimSlide Corner Box
Rivets (typ.)1/8" dia.Gutter
Box over GutterPosition Corner
PanelRoof
(2) 3/16" dia. beadTube Sealant
1/2"
TrimRake
(2) 3/16" dia. beadTube Sealant
RoofPanel
Gutter
CornerBox
1/2"
Blind Rivet1/8" dia.
Closure / Bird Stop
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_075R00BRS
PageDwg: Date: February 2012
96
ET1-1-R0
9.11 HIP AND VALLEY INSTALLATION
The above details show typical hip and valley details. Refer to the erection drawings for specific hip and valley details.
Hip conditions are similar to ridge conditions, except special end dams and back-up angles are required to accommodate the beveled roof panel ends.
Valley conditions require beveled corrugation closures to accommodate the beveled roof panel ends.
Corrugation
Valley Plate
To form corner, field cut End Dam and
with Tape Sealant and RivetsValley Pan & secure to End DamField cut and bend up end of
Valley Flashing with tabs, secure with tube
Hip Cover
Ridge Cover
Diverter
sealant and rivets
Sealant and Lap
bend end
End Dams(field cut &
tabs to fitRoof Panels)
Valley FlashingPanel bevel
2 1/2" Triple Bead
Closures with TubeSeal ends of Hip
Sealant
Field cut Roof
Hip Cover
Fasteners
2" lap with Flashing
Back-upAngle
Valley Plate
Roof Panel
ValleyFlashing
Closure
6" lap with Endlap Sealant and Roof Fasteners
Lap Fastner@ 6" o.c.
Roof Fasteners@ 6" o.c.
Endlap SealantClosure
Sealant
VALLEY SECTION
TS-324™ Roof System Installation Guide9.0 ROOF INSTALLATION DETAILS
F_TS0_076R00BRS