31 23 24 23 12.29 12.19 13.27 15.24 409 543 512 550 0.98 0.98 1.06 1.22
T5550
30.5/67.2 25/55.1 550 913 24/32 112700(33) 36
TumbledryerT5550
Certified in accordance with ISO 9001 and ISO 14001 and approved IP X4.
* Atratedcapacity100%cottonloadat50%initialmoisturedryedto0%.
24kW 32kW Gas Steam
MainspecificationsRatedcapacity, fillingfactor1:18 kg/lb fillingfactor1:22 kg/lbDrumvolume litreDrumdiameter mmHeatingalternatives electric kW gas BTU/h(kW) steamat600-700kPa kW
Consumptiondata*
Totaltimeat25kg minEnergyconsumptionat25kg kWhEvaporation g/minEnergykWh/litrewaterevaporated kWh/l
Images shown are a representation of the product only and variations may occur.
Featuresandbenefits• Axialairflowandtightconstructiongiveslowenergyconsumption• Highproductivity-2fullloadsperhour• Largedooropeningforeasyloadingandunloading• Easyandergonomicaccesstothelintscreen• ExcellentwaterevaporationefficiencyperkWh• ThecoinversionwithEcopowertoavoidoverdryingofthegarmentsand
getalowerenergyconsumption• WithCompassProprogramcontrol
- Largeandcleardisplaywithcontrolknobforeasyprogramselection- Easyaccesswithuser-friendlyinterface- Languageselection- DryingprogrampackagesoptimizedforEconomy,CareandTime- Serviceprogramforadjustmentofparameters- USBconnection
Mainoptions• Stainlesssteelfront• Stainlesssteeldrum• ResidualMoistureControl-RMC• Connectiontobooking-/payment-systemorcoinmeter• Reversingdrum• Emergencystopbutton• Supplydisconnector• Frequencycontrolledmotor
Accessories• Freshairintake• Exhaustontop• Insertfordryingspecialequipment
T5550
1”100-1000
651”
1/2”200020
2800-370028-37200
940/940940/940
1080/1080
480/950420/900
1300/1550
<70
15
2802.80
9611365144518696607201701490200180156050480580805
Share more of our thinking at www.electrolux.com
A
B(a)
E
C
B(b)
D
G
H
J
IF
K
M
N
L
1
2
7
6
5
6
37
3 4
5
8
220–240V1~ 50/60 24.0 26.2 125220–240V3~ 50/60 24.0/32.0 26.3/34.3 80/100380–415V3~ 50/60 24.0/32.0 26.7/34.7 50/50
220–240V1~ 50/60 - 1.9 10 220–240V3~ 50/60 - 2.4 10
380–415V3~ 50/60 - 2.6 10
Steam,gasandairconnections
Steam ISO7/1-RSteampressure kPaSteamconsumption kg/hCondensate ISO7/1-RGas NG/PG ISO7/1-RGaspressure Naturalgas Pa
mbarPropane Pa
mbarAiroutlet ømmMaximumairflow:
Electric50Hz/60Hz m3/hGas50Hz/60Hz m3/hSteam50Hz/60Hz m3/h
Maximumstaticbackpressure:Electric50Hz/60Hz PaGas50Hz/60Hz PaSteam50Hz/60Hz Pa
Soundlevels
AirbornesoundleveldB(A)
Heatemission
%ofinstalledpower,max
Shippingdata**
net,kgShippingvolume crated,m3
Dimensionsinmm
A WidthB(a) DepthB(b) DepthC HeightDEFGHIJKLMN
1 Controlpanel2 Dooropeningø810mm3 Electricalconnection4 Gasconnection5 Exhaustconnection6 Condensateconnection7 Steamconnection8 Lintscreen
Art
.No.
438
9137
81/2
012.
09.1
3
We
rese
rve
the
right
to
alte
r sp
ecifi
catio
ns w
ithou
t no
tice.
Front
Leftside
Rearside
El,gas Steam
www.electrolux.com/laundrysystems
* Othervoltagesavailable,seeinstallationmanual.
** Averagedata.Cratedweight/shippingvolumedependsonconfiguration.Pleasecontactlogisticsforexactmeasures.
Electricalconnections*Heating Mainvoltage Heating Total Recommendedalternative power power fuse
Hz kW kW A
Electricheated
Gasheated/Steamheated
* Customer supplied services must be located within 1 metre of each service connection point on machine for standard fittings to reach. See machine drawing for locations.
PRODUCT INSTALLATION SPECIFICATIONS MODEL T5550 CAPACITY – kgs filling factor 1:18 30.5 HEIGHT – mms 1869 WIDTH – mms 961 DEPTH – mms 1445 SPACE REQUIRED AROUND MACHINE – mms 150 Above
10 Sides 500 Behind
APPROX.WEIGHT – kgs 280 LEGS FREE STAND HEIGHT UNDER DOOR OPENING – mms 720 GAS CONNECTION – inches (dryer fitting is male) Regulated gas supply with isolation valve required. 1/2 GAS RATING – megajoules 119 MJ
NATURAL GAS PRESSURE REQUIRED. 1.13 kPa
LPG GAS PRESSURE REQUIRED. 2.75 kPa
DUCT SIZE – inches (single skin round galv. outlet). The dryer is pre-set for optimal air flow with up to 15 m equivalent pipe length. For longer pipes it is necessary to adjust the dryer according to the Manufacturers instructions within allowable limits.
200 mm
MAKE UP AIR OPENING REQUIRED (to outside). Recommended area of fresh air intake For maximum efficiency and the shortest possible drying time, it is important to ensure that fresh air is able to enter the room from the outside in the same volume as that blown out of the room. To avoid draught in the room it is important to place the air inlet behind the machine. The area of the air inlet opening is recommended to be five times the size of the exhaust pipe area. Note! Gratings/slatted covers often block half of the total fresh air vent area. Remember to take this into account. The area of the inlet opening is the area through which the air can flow without resistance from the grating/slatted cover.
0.16 m2
MAXIMUM AIR FLOW: Electric - m3/h Gas - m3/h
Steam - m3/h MAXIMUM STATIC BACK PRESSURE: Electric - - Pa Measured 1mt from exhaust outlet. Gas Pa
Steam- Pa
940 940 1080 480 420 1300
POWER CONNECTION – GAS/STEAM HEATED 3-pin GPO required. 1 phase, 240v, 10amp GPO
CIRCUIT PROTECTION AMPS – GAS/STEAM HEATED 16 STEAM HEAT Regulated steam supply with isolation valve required. - Connection – inches (1 x steam input & 1 x condensate outlet)- Required pressure – kPa- Steam Consumption Kg/Hr
2 x 1inch 100-1000
65POWER CONNECTION - WITH ELEC.HEAT 3-phase hard wire isolator required. 3 phase, 415v,
hard wired CIRCUIT PROTECTION AMPS - WITH ELEC. HEATING 50 NOISE LEVEL – Maximum dba 70
Reproduction in whole or in part is expressly forbidden except with the prior written permission of the copyright owner © Richard Jay Pty Ltd.