Turbine Flow Sensors Simultaneously Measure Flow Rate, Pressure and Temperature. Offered with US (SAE) or Metric (BSPP) Ports. 1-800-433-5263 Flo-tech by ®
Transcript
Page 1: Turbine Flow Sensors

Turbine Flow SensorsSimultaneously Measure Flow Rate, Pressure and Temperature.

Offered with US (SAE) or Metric (BSPP) Ports.

1-800-433-5263

Flo-tech

by ®

Page 2: Turbine Flow Sensors

Table of ContentsDescription Page

General Design Features

Activa Sensor Array

Ultima Sensor Array

Turbine FLow Sensors

XLI Digital Displays

XLF Digital Displays

Portable Hydraulic Testers

Sensor Array with Load Valve

SIM-Check®

F6301 Pressure Sensor

F5130, SWI-5, Square Wave Interface

F6310, Temperature Sensor with 4-20 mA outputs

Connecting Cable Chart

Common Conversion

Notes

1 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA

2

28

29

27

26

25

23-24

19-22

13-14

15-16

17-18

11-12

7-10

5-6

3-4

Mail to: Flo-tech by HedlandDivision of Racine Federated Inc.PO Box 044780Racine, WI 53404-7017

Ship to: Flo-tech by HedlandDivision of Racine Federated, Inc.2200 South StreetRacine, WI 53404

E-mail: [email protected]@[email protected]

Web-site: http://www.flo-tech.com

Customers within the United States, Canadaand U.S. possessions:Call Toll-Free: 1-800-HEDLAND

(800-433-5263)Fax Toll-Free: 1-800-CHK-FLOW

(800-245-3569)

International Customers:Phone: 262-639-6770Fax: 262-639-2267

Monday - Friday from 8 a.m. to 5 p.m. CST

Page 3: Turbine Flow Sensors

2 FAX: 1- 800- 245-3569

General Design Features

➁➂

➀➆

➁➈ ➂

LEARN ABOUT OTHER D IV IS IONS‘ PRODUCTS

1 – Housing2 – Turbine rotor3 – Rotor Supports4 – Lock Nut5 – Magnetic Pickup (frequency output)

6 – Signal Converter (4-20mA output)7 – Pressure Port Adapter8 – Temperature Port Adapter9 – Retainer Rings

OPERATING PRINCIPLETurbine flow sensors measure the flow rate of hydraulic fluid andcompatible liquids. As fluid flows through the sensor it turns the turbine rotor, and as each turbine blade passes the magnetic pickupan electrical signal is generated. This frequency signal is proportionalto the flow rate and can be transmitted to Flo-tech’s digital displays or converted to a 4-20mA output. Optional sensors allow measurement of pressure, temperature, and speed.

Rugged construction: Flow sensors are constructed in anodizedaluminum* with SAE, BSPP, Code 61 and Code 62, 4-bolt flangedports. The sensor arrays have a forward flow accuracy of +/-1% fullscale, fluid temperature range of -4 to 300°F, and are available inpressure ratings up to 6000 psi.

Accuracy: The sensor arrays have a forward flow accuracy of +/-1%full scale while monitoring hydraulic liquids with viscosity and specificgravity similar to factory calibrated fluids.

Linearization: Flo-tech flow sensors are linear which provides a significant increase in accuracy. The output of the flow sensor variesby the same percentage as the flow through the meter.

Bi-directional flow capability: Turbine flow sensors are inherentlybi-directional, as the turbine will function normally in reverse condition.Flo-tech does not guarantee accuracy in reverse flow, however, it isgenerally in the range of +/-1.5% to +/-2% of full scale. If required, a reverse flow calibration is optional.

Flow straighteners: While flow straighteners are manufactured intoeach sensor, it is recommended that at least 10 port diameters ofupstream pipe with no obstructions to the flow sensor and at least 5 port diameters downstream pipe be provided to obtain laminar flow.

Filtration: All applications should be filtered to at least 40 micron.Placing the flow sensor at a higher elevation in the system will avoidcollection of debris, sediment, and dirt in the sensor.

Viscosity: As long as the fluid viscosity remains within a range of 50-500 SUS or 10 cST to 100 cST, the flow sensors will stay withinthe +/-1% of full flow specifications.

Calibration: Flow meters are calibrated with 0.876 specific gravity,140 SUS (32 cST) hydraulic oil, irrespective of final fluid use. Standardcalibration is done using 3-points however, 5- and 10-point calibrationcertification is also available. If accuracy greater than 1% is required,please consult factory. This can be accomplished through additionalcalibration measures.

Repeatability: Flow meter repeatability is within +/- 0.2%. This is particularly important in cylical applications which require consistentreadings.

* Portable testers constructed in cold-rolled steel. 6013-T651/FSD series in zinc-plated,stress-proof steel.

Page 4: Turbine Flow Sensors

3 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S

Activa Sensor ArraySeries F6200A / F6220ASimultaneously Measures Flow, Pressure and Temperature

• Four flow ranges• Turbine Flow Measurement • Pressures up to 5800 psi• Temperatures up to 300° F• Three sensors - one line break• 4-20 mA sensor outputs

The Activa Sensor Array provides flow, temperature and pressure signals in a compactunit that requires only one hydraulic line break.Each sensor transmits a 4-20 mA output signalthat is easily integrated with PCs, PLCs,recorders or panel displays. Signals can also be transmitted to Flo-tech XLI displays or theSIM-Check hydraulic system analyzer.

Typical applications include fluid characteristicmeasurement on test stands, stationaryhydraulic system monitoring, feedback forhydraulic system control, advance warning ofimpending component failure and mobilehydraulic system diagnosis.

SPECIFICATIONS:MATERIAL:Housing: 6013-T651 Anodized aluminumAdapters: 6061-T6 Anodized aluminumTurbine Rotor: T416 Stainless steelRotor Supports: 6061-T6 Aluminum;

C360 Brass for models F6202-A and F6222-A

Rotor Shaft: T303 Stainless steelPORTS: SAE J1926/1, BSPP ISO1179MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish

Lock Nut – 12L14 steel, zinc plate, dichromate finishSIGNAL CONVERTER: Body – Nickel-plated 6061-T6 aluminum

Connectors – Nickel-plated brassElectrical:Excitation Range: 6 – 28 VDCOutput Current Range: 4 – 20 mAMinimum Load Resistance: 10 ohmsMaximum Load Resistance:

Excitation Voltage –1V.02

PERFORMANCE:Forward flow accuracy: ±1% of full scale

± 0.5% of rate when used with XLI display.Repeatability: ± 0.2%Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for

models F6208-A and F6228-APressure drop: See ∆ P charts.Turbine response: < 200 msFluid temperature range: -4° to 300° F (-20° to 150° C)Ambient temperature range: -4° to 131° F (-20° to 55° C)BI-DIRECTIONAL FLOW: Optional calibration available

B

A

D

C

SignalConverter

Pressure PortAdapter Temperature

Port AdapterHousing

MagneticPickup

Ball Bearings: 440 C Stainless steelHub Cones: 6061-T6 Aluminum alloy Retainer Rings: 6061-T6 Aluminum alloySeals: Buna N standard; Viton and

EPR optional

Circuit Power Requirement: Load + 7.0 mAAccuracy: ±0.5% of full scale span, plusaccuracy of input sourceThermal Drift: ≤ 0.05% F.S. /° F

Bulletin #512

DIMENSIONS:

1.23 (31.2) 4.72 (120.0) 1.47 (37.3) 5.74 (145.6)

1.48 (37.6) 5.08 (129.0) 1.80 (45.7) 6.04 (153.0)

1.98 (50.3) 5.87 (149.0) 2.20 ( 56.0) 6.50 (164.0)

2.46 (62.5) 6.81 (173.0) 2.48 (63.0) 6.74 (171.0)

F6202-AF6222-A

F6204-AF6224-A

F6206-AF6226-A

F6208-AF6228-A

SERIES WIDTHin (mm)

LENGTHin (mm)

HEIGHTin (mm)

W/MAGin (mm)

A B C D

1.60

1.90

2.80

4.20

WEIGHT(lbs)

32

1

1 – Common2 – 4-20 mA output3 – +VDC

Page 5: Turbine Flow Sensors

4 FAX: 1- 800- 245-3569 CALL TO DISCUSS YOUR SPECIFIC APPLICATION

Activa Sensor ArraySeries F6200A / F6220A

Simultaneously Measures Flow, Pressure and Temperature

THE ACTIVA SENSOR ARRAY PRESSURE DROP CHART

ORDERING INFORMATION:

PRESSURESENSOR PORTS

TEMPERATURE SEALSMODEL

SealsB Buna NV VitonE EPR

( Example ) F6204 – A B - T 6

TemperatureT with SensorN 1/4 NPTF (F) PluggedS SAE #2 (J514) PluggedG G 1/4 (F) PluggedD SAE #4

Pressure1 1000 psi (69 bar) Sensor3 3000 psi (207 bar) Sensor5 5000 psi (345 bar) Sensor6 6000 psi (414 bar) SensorN 1/4 NPTF (F) PluggedS SAE #2 (J514) PluggedF G 1/4 (F) Plugged

Ordering Example:F6204 - A B-T6, SAE 16, 2-40 gpm with Buna N seals, temperature sensor and 6000 psi pressure sensor.

FLOW RATENOMINAL PORT SIZE

F6202 – AF6204 – AF6206 – AF6208 – AF6222 – AF6224 – AF6226 – AF6228 – A

0.4 - 7 GPM2 - 40 GPM4 - 80 GPM

8 - 160 GPM1.5 - 26 LPM

7.5 - 151 LPM15 - 302 LPM30 - 605 LPM

10.0 (0.69) 26.0 (1.79)9.0 (0.62) 25.0 (1.72)9.0 (0.62) 30.0 (2.07)8.0 (0.55) 30.0 (2.07)10.0 (0.69) 26.0 (1.79)9.0 (0.62) 25.0 (1.72)9.0 (0.62) 30.0 (2.07)8.0 (0.55) 30.0 (2.07)

SAE 8SAE 12SAE 16SAE 20G 1/4G 3/4G 1G 1-1/4

B* S* N*

PRESSURE DROP PSI (BAR) 50% MAX FLOW 100% MAX FLOW

1

.1.1

10

100

1 10 100 300

FLOW GPM

PR

ES

SU

RE

DR

OP

PS

I

F6208F6206F6204F6202

.01

.006

.1

1.0

6

.3 10 100 1000

FLOW LPM

PR

ES

SU

RE

DR

OP

BA

R

F6222 F6224F6226 F6228

*Basic ModelThe 4-20mA electronics can be set to either “sink or source.” If the “load sink” is specified, the load sensing resistor is connected to the positive side of the excitation voltage. If “load source” is specified, the load sensing resistor is connected to the negative side of the excitation voltage. If ordered as part of a sensor array, the above specification is sufficient. If not specified, the 4-20mA signal will be “current sourcing”, using 600 ohms at 24 VDC.

When using Activa Sensor Array with Flo-tech’s XLI Digital Displays, use F6234-6, 6-ft. or F6234-15, 15-ft. connecting Cables on page 27.

Five or Ten Point Calibration Certificates are available. Flo-tech P.N. Description F001109 Five Point Calibration Certificate F001110 Ten Point Calibration Certificate These certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A

*Basic Model

Page 6: Turbine Flow Sensors

5 TEL.1-800-433-5263 V I S I T O U R W E B S I T E – F L O - T E C H . C O M

Ultima Sensor ArraySeries F6200F / F6220FSimultaneously Measures Flow, Pressure and Temperature

• Four flow ranges• Turbine Flow Measurement • Pressures up to 5800 psi• Temperatures up to 300° F• Three sensors - one line break

The Ultima Sensor Array provides flow, temperature and pressure signals in a compactunit that requires only one hydraulic line break.The magnetic pickup generates a frequencyoutput and the pressure and temperature sensors transmit a 4-20 mA output signal that is easily integrated with PC’s, PLC’s,recorders or panel displays. The signals can be transmitted to Flo-tech’s XLF & XLI digitaldisplays or any other instruments that accept a frequency or 4-20 mA signal.

Typical applications include fluid characteristicmeasurement on test stands, stationaryhydraulic system monitoring, feedback forhydraulic system control, advance warning ofimpending component failure and mobilehydraulic system diagnosis.

SPECIFICATIONS:MATERIAL:Housing: 6013-T651 Anodized aluminumAdapters: 6061-T6 Anodized aluminumTurbine Rotor: T416 Stainless steelRotor Supports: 6061-T6 Aluminum; C360 Brass for models F6202-A and F6222-ARotor Shaft: T303 Stainless steelBall Bearings: 440 C Stainless steelHub Cones: 6061-T6 Aluminum alloyRetainer Rings: 6061-T6 Aluminum alloySeals: Buna N standard; Viton and EPR optionalPORTS: SAE J1926/1, BSPP ISO1179MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish

Nut – 12L14 steel, zinc plate, dichromate finishPERFORMANCE: Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.

The F6202 / F6222 models have a 10 mV RMS (200 Hz) min.Forward flow accuracy: ±1% of full scale

± 0.5% of rate when used with XLF display.Repeatability: ± 0.2%Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for

models F6208-F and F6228-FPressure drop: See ∆ P charts.Turbine response: < 200 msFluid temperature range: -4° to 300° F (-20° to 150° C)Ambient temperature range: -4° to 131° F (-20° to 55° C)BI-DIRECTIONAL FLOW: Optional calibration available

DIMENSIONS:

1.23 (31.2) 4.72 (120.0) 1.47 (37.3) 3.72 (94.5)

1.48 (37.6) 5.08 (129.0) 1.80 (45.7) 4.05 (102.9)

1.98 (50.3) 5.87 (149.0) 2.20 ( 56.0) 4.46 (113.3)

2.46 (62.5) 6.81 (173.0) 2.48 (63.0) 4.75 (120.7)

F6202-FF6222-F

F6204-FF6224-F

F6206-FF6226-F

F6208-FF6228-F

SERIES WIDTHin (mm)

LENGTHin (mm)

HEIGHTin (mm)

W/MAGin (mm)

1.55

1.75

2.75

4.10

WEIGHT(lbs)

A B C D

Bulletin #513

B A

D

C

Pressure PortAdapter

Temperature Port AdapterHousing

Magnetic Pickup

Page 7: Turbine Flow Sensors

6 FAX: 1- 800- 245-3569 F IVE OR TEN PO INT CAL IBRAT ION AVA ILABLE

Ultima Sensor ArraySeries F6200F / F6220F

Simultaneously Measures Flow, Pressure and Temperature

CABLES

PAGE XLF DIGITAL DISPLAYS

PAGE 13TEMPERATURE SENSORS PRESSURE SENSORS

PAGE PAGE23 26 27

THE ULTIMA SENSOR ARRAY PRESSURE DROP CHART

ORDERING INFORMATION:

PRESSURESENSOR PORTS

TEMPERATURE SEALSMODEL

SealsB Buna NV VitonE EPR

( Example ) F6204 – F B - T 6

TemperatureT with SensorN 1/4 NPTF (F) PluggedS SAE #2 (J514) PluggedG G 1/4 (F) PluggedD SAE #4

Pressure1 1000 psi (69 bar) Sensor3 3000 psi (207 bar) Sensor5 5000 psi (345 bar) Sensor6 6000 psi (414 bar) SensorN 1/4 NPTF (F) PluggedS SAE #2 (J514) PluggedF G 1/4 (F) Plugged

Ordering Example:F6204 - F B-T6, SAE 16, 2-40 gpm with Buna N seals,temperature sensor and 6000 psi pressure sensor

*Basic Model**Requires SWI-5, Square Wave Interface (F5130, page 25) to amplify signal to be compatible with XLF digital display. Connecting cable part numbers are F2836-6, 6-ft. or F2836-15, 15-ft. on page 27.

When using Ultima Sensor Array with Flo-tech’s XLF Digital Displays use F6234-6, 6-ft. or F6234-15, 15-ft. connecting cables on page 27.Five or Ten Point Calibration Certificates are available. Flo-tech P.N. Description F001109 Five Point Calibration Certificate F001110 Ten Point Calibration Certificate These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A

FLOW RATENOMINAL PORT SIZE

F6202 – FF6204 – FF6206 – FF6208 – FF6222 – FF6224 – FF6226 – FF6228 – F

0.4 - 7 GPM2 - 40 GPM4 - 80 GPM

8 - 160 GPM1.5 - 26 LPM

7.5 - 151 LPM15 - 302 LPM30 - 605 LPM

10.0 (0.69) 26.0 (1.79)9.0 (0.62) 25.0 (1.72)9.0 (0.62) 30.0 (2.07)8.0 (0.55) 30.0 (2.07)10.0 (0.69) 26.0 (1.79)9.0 (0.62) 25.0 (1.72)9.0 (0.62) 30.0 (2.07)8.0 (0.55) 30.0 (2.07)

SAE 8 **SAE 12SAE 16SAE 20G 1/4 **G 3/4G 1G 1-1/4

B* S* N*

PRESSURE DROP PSI (BAR) 50% MAX FLOW 100% MAX FLOW

1

.1.1

10

100

1 10 100 300

FLOW GPM

PR

ES

SU

RE

DR

OP

PS

I

F6208F6206F6204F6202

.01

.006

.1

1.0

6

.3 10 100 1000

FLOW LPM

PR

ES

SU

RE

DR

OP

BA

R

F6222 F6224F6226 F6228

*Basic Model

Page 8: Turbine Flow Sensors

7 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA

Turbine Flow SensorsSeries FSC / FSB / FSD• Variety of Body Materials &

Fluid Connections• Turbine Flow Measurement• Flow Ranges from 0.4 to 350 GPM• Pressures up to 6000 PSI• Temperatures up to 300° F• Petroleum-based fluids

Classic Turbine Flow Sensors measure the flowrate of hydraulic fluids and other compatible liquids. As fluid flows through the sensor it turnsthe turbine rotor and as each turbine bladepasses the magnetic pickup an electrical signal is generated. This frequency signal is proportional to flow rate and can be transmittedto Flo-tech’s XLF digital displays to show gpm,lpm, rpm and other common units of measure.

SPECIFICATIONS:MATERIAL:Housing: FSC, FSB – 6013-T651 Anodized aluminum; FSD – Stressproof® steel,

zinc platedTurbine Rotor: T416 Stainless SteelRotor Supports: FSC-375, 500, 750 – Brass C360; FSC-1000, 1005; FSB – 6061-T6,

Aluminum alloy; FSD, T303 Stainless steelRotor Shaft: FSC, FSB – T303 Stainless steel; FSD, Tungsten carbideBall Bearings: FSC, FSB – 440 C Stainless steel: FSD, Tungsten carbideHub Cones: FSC, FSB – 6061-T6 Aluminum alloyRetainer Rings: FSC-375 – T303 Stainless steel: FSC-500, 750, 1000, 1005;

FSB, FSD – zinc plated steelSeals: Buna-N, standard; Viton and EPR, optionalPORTS: SAE J1926/1, Code 61 and Code 62: SAE J518MAGNETIC PICKUP:

For the FSC, FSB, FSD: Body – 12L14 steel, black oxide finishNut – 12L14 steel, zinc plate, dichromate finish

SERIES MODEL DIMENSIONS (mm) WEIGHTNUMBER A (WIDTH) B (LENGTH) C (HEIGHT) D (W/MAG) (LB)

FSC-375* F2945-ASCM 1.25 (32) 5.00 (127) 1.50 (38) 3.91 (99) 1.25FSC-500 F2082-ASCM 2.00 (51) 6.50 (165) 2.00 (51) 4.16 (106) 2.75FSC-750 F2083-ASCM 2.00 (51) 6.50 (165) 2.00 (51) 4.25 (108) 2.87FSC-1000 F2084-ASCM 2.50 (64) 6.50 (165) 2.00 (51) 4.34 (110) 3.25FSC-1005 F2084-ASCM8 2.50 (64) 6.50 (165) 2.00 (51) 4.34 (110) 3.25FSB-1250 F2085-ASBM 4.00 (102) 7.00 (178) 3.00 (76) 4.94 (126) 7.75FSB-1500 F2086-ASBM 4.00 (102) 7.00 (178) 3.00 (76) 5.10 (130) 7.40FSD-1250 F2085-SCDM 2.12 (54) 7.50 (190) 4.50 (114) 6.12FSD-1500 F2086-SCDM 2.50 (64) 7.50 (190) 4.85 (123) 6.75FSD-2000 F2998-SCDM 3.12 (79) 8.25 (209) 5.39 (137) 8.55

Bulletin #200

FSC

D

A

B

C

Magnetic Pickup

Housing

D

A

B

C

Magnetic Pickup

Housing

FSB

D

A

B

C

Magnetic Pickup

Housing

FSD

Page 9: Turbine Flow Sensors

XLF DIGITAL DISPLAYS

PAGE 13CABLES

PAGESWI-5 AMPLIFIER

PAGE ACTIVA FLOW SENSORS

PAGE25 273

8 FAX: 1- 800- 245-3569 LEARN ABOUT OTHER D IV IS IONS ’ PRODUCTS

Turbine Flow SensorsSeries FSC / FSB / FSD

SPECIFICATIONS (cont.):PERFORMANCE:Electrical Output Signal: Self-generating alternating pulse. The

FSC-500, 750, 1000, 1005; FSB; FSD, generate a 100 mV RMS (100 Hz) minimum. The FSC-375, generate a 10 mVRMS (200 Hz) minimum.

Forward Flow Accuracy: +/- 1% of full flow rate

Repeatability: +/- 0.2%Pressure Rating: FSC, FSB – 5000 PSI (345 Bar) maximum;

FSD – 6000 PSI (414 Bar) maximumPressure Drop: See ∆ P chartTurbine Response: < 200 MSFluid Temperature Range: -4° to 300° F (-20° to 150° C)

BI-DIRECTIONAL FLOW: Optional calibration available

SERIES MODEL NOMINAL FLOW (LPM) PRESSURE DROP PSI (BAR)NUMBER PORT SIZE RATE 50% 100%

MAX FLOW MAX FLOWFSC-375* F2945-ASCM SAE 8, 1/2" O-Ring Boss 0.4 - 7 (1.5-26) 9.0 (.62) 27 (1.86)FSC-500 F2082-ASCM SAE 12, 3/4" O-Ring Boss 1-15 (4-56) 7.0 (.48) 20 (1.38)FSC-750 F2083-ASCM SAE 12, 3/4" O-Ring Boss 2-25 (7.5-94) 2.4 (.17) 8 (.55)

FSC-1000 F2084-ASCM SAE 16, 1" O-Ring Boss 3-60 (11.5-227) 5.6 (.38) 21 (1.45)FSC-1005 F2084-ASCM8 SAE 16, 1" O-Ring Boss 4-85 (15-321) 11.0 (.76) 38 (2.62)FSB-1250 F2085-ASBM SAE 20, 1-1/4" Code 61, 4-Bolt Face 5-100 (20-378) 1.6 (.11) 15 (1.03)FSB-1500 F2086-ASBM SAE 24, 1-1/2" Code 61, 4-Bolt Face 7-200 (27-757) 5.5 (.38) 25 (1.72)FSD-1250 F2085-SCDM SAE 20, 1-1/4" Code 62, Flange Head 5-100 (20-378) 1.6 (.11) 15 (1.03)FSD-1500 F2086-SCDM SAE 24, 1-1/2" Code 62, Flange Head 7-200 (27-757) 5.5 (.38) 25 (1.72)FSD-2000 F2998-SCDM SAE 32, 2" Code 62, Flange Head 10-350 (37-1324) 4.5 (.31) 20 (1.38)

*Requires SWI-5, square wave interface (F5130, page 25) to amplify signal to be compatible with Flo-tech’s XLF Digital Display.

When using Classic Turbine Flow Sensors with Flo-tech’s XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.

Five or Ten Point Calibration Certificates are available.Flo-tech P.N. DescriptionF001109 Five Point Calibration CertificateF001110 Ten Point Calibration CertificateThese Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A

ORDERING INFORMATION

1

0.1

0.07

4

10 100 1000 2000

FSC-500

PR

ES

SU

RE

DR

OP

BA

R

FLOW LPM

FSC-750

FSC-1000FSC-1005

FSB-1250FSD-1250

FSB-1500FSD-1500

FSD-2000FSC-375

1

10

50

1 10 100 500

FLOW GPM

PR

ES

SU

RE

DR

OP

PS

I

FSC-500

FSC-375

FSC-750

FSC-1000FSC-1005

FSB-1250FSD-1250

FSB-1500FSD-1500

FSD-2000

Page 10: Turbine Flow Sensors

9 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S

Turbine Flow SensorsQuad Series• Turbine Flow Measurement• Flow Ranges from 1 to 85 GPM• Pressures up to 5000 PSI• Temperatures up to 300° F• Petroleum-based fluids

Derived from the FSC Series, the F2000 Quadseries of flow meters utilizes two flow transducers which are 90-degrees electrically outof phase from each other. As fluid flows throughthe sensors it turns the turbine rotor and as eachblade passes the magnetic pickup an electricalsignal is generated.

With the addition of a second flow sensor, it ispossible to monitor flow in both directions. TheF2000 Quad is suitable for up-down countersthat can discern the leading and trailing edges ofthe two 90-degree signals. Current applicationsinclude using the F2000 as a speed-sensingdevice on mobile equipmeent. This bi-directionalflow meter can be used as a governor, sendingfrequency signals back to a PLC which enable it to make the necessary adjustments. Otherfunctions of this flow meter are in linear applications where accurate positioning is required.

Linearization, where the output of the flow sensor varies by the same percentage as theflow through the meter, assists the F2000 Quadseries in achieving its +/-1% of full scale accuracy in both directions. Flow straightenersare manufactured into each meter to obtain alaminar flow, also increasing accuracy. Standardcalibration is done using 5-points.

SPECIFICATIONS:MATERIAL:Housing: FSC, 2024-T351 Anodized aluminumTurbine Rotor: T416 Stainless SteelRotor Supports: FSC – Brass C360Rotor Shaft: FSC – T303 Stainless steelBall Bearings: FSC – 440 C Stainless steelHub Cones: FSC – 6061-T6 Aluminum alloyRetainer Rings: FSC – zinc plated steelSeals: Buna-N, standard; Viton and EPR, optionalPORTS: SAE J1926/1, Code 61 and Code 62: SAE J518MAGNETIC PICKUP:

Body – 12L14 steel, black oxide finishNut – 12L14 steel, zinc plate, dichromate finish

SERIES MODEL DIMENSIONS (mm)NUMBER A (WIDTH) B (LENGTH) C (HEIGHT) D (W/MAG) E

FSC-2005 F2082-ASCQ4 2.00 (51) 6.50 (165) 2.00 (51) 4.16 (106) 4.05 (102)FSC-2075 F2083-ASCQ4 2.00 (51) 6.50 (165) 2.00 (51) 4.25 (108) 4.05 (102)FSC-2100 F2084-ASCQ4 2.50 (64) 6.50 (165) 2.00 (51) 4.34 (110) 4.59 (117)FSC-2150 F2085-ASCQ4 2.50 (64) 6.50 (165) 2.00 (51) 4.34 (110) 4.59 (117)

Bulletin #200

QUAD

D

AE

Magnetic Pickup (2)

Housing

C

B

Page 11: Turbine Flow Sensors

XLF DIGITAL DISPLAYS

PAGE 13CABLES

PAGESWI-5 AMPLIFIER

PAGE ACTIVA FLOW SENSORS

PAGE25 273

FAX: 1- 800- 245-3569 10CALL TO DISCUSS YOUR SPECIFIC APPLICATION

Turbine Flow SensorsQuad Series

SPECIFICATIONS (cont.):PERFORMANCE:Electrical Output Signal: Self-generating alternating pulse. The

FSC-2005, 2075, 2100, 2150, generate a 100 mV RMS (100 Hz) minimum.

Forward Flow Accuracy: +/- 1% of full flow rateReverse Flow Accuracy: +/- 1% of full flow rate

Repeatability: +/- 0.2%Pressure Rating: 5000 PSI (345 Bar) maximum;Pressure Drop: See ∆ P chartTurbine Response: < 200 MSFluid Temperature Range: -4° to 300° F (-20° to 150° C)

SERIES MODEL NOMINAL FLOW (LPM) PRESSURE DROP PSI (BAR)NUMBER PORT SIZE RATE 50% 100%

MAX FLOW MAX FLOWFSC-500 F2082-ASCM SAE 12, 3/4" O-Ring Boss 1-15 (4-60) 7.0 (.48) 20 (1.38)FSC-750 F2083-ASCM SAE 12, 3/4" O-Ring Boss 2-25 (7.5-94) 2.4 (.17) 8 (.55)

FSC-1000 F2084-ASCM SAE 16, 1" O-Ring Boss 3-60 (11.5-227) 5.6 (.38) 21 (1.45)FSC-1005 F2084-ASCM8 SAE 16, 1" O-Ring Boss 4-85 (15-321) 11.0 (.76) 38 (2.62)

When using Quad Turbine Flow Sensors with Flo-tech’s XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.

Five or Ten Point Calibration Certificates are available.Flo-tech P.N. DescriptionF001109 Five Point Calibration CertificateF001110 Ten Point Calibration CertificateThese Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A

ORDERING INFORMATION

1

0.1

0.07

4

10 100 1000 2000

FSC-2005

FSC-2075

FSC-2100FSC-2150

PR

ES

SU

RE

DR

OP

BA

R

FLOW LPM

1

10

50

1 10 100 500

FLOW GPM

PR

ES

SU

RE

DR

OP

PS

I

FSC-2005

FSC-2075

FSC-2100FSC-2150

Page 12: Turbine Flow Sensors

TEL. 1-800-433-5263 FAX 1-800-245-3569

Digital DisplayFor Flo-tech Activa Sensor Arrays

Digital DisplayFor Flo-tech Ultima and Classic Turbine Flow Sensors

Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal

www.flo-tech.com www.flo-tech.comby Hedland by Hedland

SPECIFICATIONS:

Display: 5-digit, 0.56" sunlight-readable red LEDPower:AC 85 to 250 VAC, 50/60 Hz, 15 VADC 11 to 36 VDC, 11 WA/D Converter: 16-bit resolutionA/D Conversion Rate: 20 readings/secDisplay Update Rate: 1 to 20 updates/secSensor Inputs: 4 to 20 mA or 0 to 10 VDCTransmitter Power: 24 VDC, ±5%, regulated 50 mA max Totalizer Time Base: Second, minute, hour or dayTotal: 9 digits, display alternates between high order and low order readoutsLinearization DataPoint Pairs: Selectable from 2 to 16Operating Temperature: 32 °F to 122 °F (0 °C to 50 °C) ( 32 °F to 113 °F with all three plug-in cards installed)

SPECIFICATIONS:

Display: 6-digit, 0.56" sunlight-readable red LEDRate 5-digit max, ±0.01% accuracyCounter 8-digit max, >6 digits alternates between high order and low orderPower:AC 85 to 250 VAC, 50/60 Hz, 18 VADC 11 to 36 VDC, 14 WSensor Power: 12 VDC, ±10%, 100 mA max, short circuit protectedInputs: Magnetic pickupFrequency Range 0.01 to 34 K HzTrigger Sensitivity 80 mV p-pOver Voltage Protected ±40 V peakOperating Temperature: 32 °F to 122 °F (0 °C to 50 °C) ( 32 °F to 113 °F with all three plug-in cards installed)

Applications• Remote flow meter monitoring• Rate comparisons• Alarm processing• Process control

Features• 5-digit rate display• 5-digit totalizer with 4-digit overcarry• Dual inputs, 4-20 mA or 0-10 VDC• Built-in transmitter power supply• Three plug-in card slots• Optional setpoint alarm cards• AC and DC powered versions• NEMA 4X / IP65 rated• CE compliant

Applications• Remote flow meter monitoring• Totalizing• Alarm processing• Process control

4.1(104.1)

0.10(2.5)

1.75(44.5)

MAXMINTOT

SP1 SP2 SP3 SP4

DSP PAR F1 F2 RST

3.80( 96.5 )

1.95(49.5)

4.1(104.1)

0.10(2.5)

1.75(44.5)

ABC

SP1 SP2 SP3 SP4

DSP PAR F1 F2 RST

3.80( 96.5 )

1.95(49.5)

The F6700/F6750 series digital display with integrated signal processor accepts a 4-20 mA signal from Flo-tech’s Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC source. These 5-digit displays can be scaled to most engineering units and are easily programmed using the front panel buttons or available programming software. To meet your specific requirements, each display accepts up to three optional plug-in cards. One card for each of the following function types can be installed in each display:Analog Outputs – A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20 mA or 0-10 VDC signal and can be scaled independent of the input range.Communications – Optional plug-in cards to facilitate digital communications include: RS232, RS485, Modbus, Profibus and DeviceNet.Setpoint Alarms – Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or either sinking or sourcing quad open collector logic outputs.The analog output and communication cards will be installed by the factory at time of order, or they may be installed by the customer at a later date. The setpoint alarm cards are available for customer installation and setup only.

Form C Relay Plug-in Option Card - Part Number F6542This optional plug-in card requires customer installation and setup. To facilitate setup, it is recommended that this feature be utilized with a display that includes a serial communication card (RS232 or RS485) and programming software.

Note: For additional setpoint alarm options, consult factory for information.

Features• 6-digit display• Count, rate and slave display• Built-in sensor power supply• Three plug-in card slots• Optional setpoint alarm cards• AC and DC powered versions• NEMA 4X / IP65 rated• CE compliant

The F6600/F6650 series rate/counter digital display with integrated signal processor accepts the frequency signal from Flo-tech’s Ultima and Classic Turbine Flow Sensors as well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL circuits and magnetic pickups. These meters provide six different display indications, including: Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.Annunciators indicate which display is being shown.

Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons through the addition of three types of optional plug-in cards: analog outputs, communications and setpoint alarms. The analog output and communication cards can be installed by the factory at the time of order, or they may be installed by the customer at a later date. The setpoint alarm cards are available for customer installation and setup only.

A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375, F6202-F, F6222-F and the F6600/F6650 series displays.

Form C Relay Plug-in Option Card - Part Number F6542This optional plug-in card requires customer installation and setup. To facilitate setup, it is recommended that this feature be utilized with a display that includes a serial communication card (RS232 or RS485) and programming software.

Note: For additional setpoint alarm options, consult factory for information.

Inches(mm)

Inches(mm)

Power

Display Analog Output Communications Display Units

AC F6700 4-20 mA – A RS232 – A GPM – G DC F6750 0-20 mA – B RS485 – B LPM – L

0-10 VDC – C Modbus – C RPM – R

None – X Profibus – D psi – P

DeviceNet – E bars – B

None – X kg/cm2 – K

MPa – M

°F – F

°C – CNote: Select one option from each category

Ordering Information:

Power

Display Analog Output Communications Display Units

AC F6600 4-20 mA – A RS232 – A GPM – G DC F6650 0-20 mA – B RS485 – B LPM – L

0-10 VDC – C Modbus – C RPM – R

None – X Profibus – D

DeviceNet – E

None – X Note: Select one option from each category

Ordering Information:

2 3

Ordering Examples:

F6600-X-X-G = AC powered, displays GPM

F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM

F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM

Ordering Examples:

F6700-X-X-G = AC powered, displays GPM

F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM

F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars

Page 13: Turbine Flow Sensors

TEL. 1-800-433-5263 FAX 1-800-245-3569

Digital DisplayFor Flo-tech Activa Sensor Arrays

Digital DisplayFor Flo-tech Ultima and Classic Turbine Flow Sensors

Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal

www.flo-tech.com www.flo-tech.comby Hedland by Hedland

SPECIFICATIONS:

Display: 5-digit, 0.56" sunlight-readable red LEDPower:AC 85 to 250 VAC, 50/60 Hz, 15 VADC 11 to 36 VDC, 11 WA/D Converter: 16-bit resolutionA/D Conversion Rate: 20 readings/secDisplay Update Rate: 1 to 20 updates/secSensor Inputs: 4 to 20 mA or 0 to 10 VDCTransmitter Power: 24 VDC, ±5%, regulated 50 mA max Totalizer Time Base: Second, minute, hour or dayTotal: 9 digits, display alternates between high order and low order readoutsLinearization DataPoint Pairs: Selectable from 2 to 16Operating Temperature: 32 °F to 122 °F (0 °C to 50 °C) ( 32 °F to 113 °F with all three plug-in cards installed)

SPECIFICATIONS:

Display: 6-digit, 0.56" sunlight-readable red LEDRate 5-digit max, ±0.01% accuracyCounter 8-digit max, >6 digits alternates between high order and low orderPower:AC 85 to 250 VAC, 50/60 Hz, 18 VADC 11 to 36 VDC, 14 WSensor Power: 12 VDC, ±10%, 100 mA max, short circuit protectedInputs: Magnetic pickupFrequency Range 0.01 to 34 K HzTrigger Sensitivity 80 mV p-pOver Voltage Protected ±40 V peakOperating Temperature: 32 °F to 122 °F (0 °C to 50 °C) ( 32 °F to 113 °F with all three plug-in cards installed)

Applications• Remote flow meter monitoring• Rate comparisons• Alarm processing• Process control

Features• 5-digit rate display• 5-digit totalizer with 4-digit overcarry• Dual inputs, 4-20 mA or 0-10 VDC• Built-in transmitter power supply• Three plug-in card slots• Optional setpoint alarm cards• AC and DC powered versions• NEMA 4X / IP65 rated• CE compliant

Applications• Remote flow meter monitoring• Totalizing• Alarm processing• Process control

4.1(104.1)

0.10(2.5)

1.75(44.5)

MAXMINTOT

SP1 SP2 SP3 SP4

DSP PAR F1 F2 RST

3.80( 96.5 )

1.95(49.5)

4.1(104.1)

0.10(2.5)

1.75(44.5)

ABC

SP1 SP2 SP3 SP4

DSP PAR F1 F2 RST

3.80( 96.5 )

1.95(49.5)

The F6700/F6750 series digital display with integrated signal processor accepts a 4-20 mA signal from Flo-tech’s Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC source. These 5-digit displays can be scaled to most engineering units and are easily programmed using the front panel buttons or available programming software. To meet your specific requirements, each display accepts up to three optional plug-in cards. One card for each of the following function types can be installed in each display:Analog Outputs – A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20 mA or 0-10 VDC signal and can be scaled independent of the input range.Communications – Optional plug-in cards to facilitate digital communications include: RS232, RS485, Modbus, Profibus and DeviceNet.Setpoint Alarms – Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or either sinking or sourcing quad open collector logic outputs.The analog output and communication cards will be installed by the factory at time of order, or they may be installed by the customer at a later date. The setpoint alarm cards are available for customer installation and setup only.

Form C Relay Plug-in Option Card - Part Number F6542This optional plug-in card requires customer installation and setup. To facilitate setup, it is recommended that this feature be utilized with a display that includes a serial communication card (RS232 or RS485) and programming software.

Note: For additional setpoint alarm options, consult factory for information.

Features• 6-digit display• Count, rate and slave display• Built-in sensor power supply• Three plug-in card slots• Optional setpoint alarm cards• AC and DC powered versions• NEMA 4X / IP65 rated• CE compliant

The F6600/F6650 series rate/counter digital display with integrated signal processor accepts the frequency signal from Flo-tech’s Ultima and Classic Turbine Flow Sensors as well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL circuits and magnetic pickups. These meters provide six different display indications, including: Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.Annunciators indicate which display is being shown.

Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons through the addition of three types of optional plug-in cards: analog outputs, communications and setpoint alarms. The analog output and communication cards can be installed by the factory at the time of order, or they may be installed by the customer at a later date. The setpoint alarm cards are available for customer installation and setup only.

A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375, F6202-F, F6222-F and the F6600/F6650 series displays.

Form C Relay Plug-in Option Card - Part Number F6542This optional plug-in card requires customer installation and setup. To facilitate setup, it is recommended that this feature be utilized with a display that includes a serial communication card (RS232 or RS485) and programming software.

Note: For additional setpoint alarm options, consult factory for information.

Inches(mm)

Inches(mm)

Power

Display Analog Output Communications Display Units

AC F6700 4-20 mA – A RS232 – A GPM – G DC F6750 0-20 mA – B RS485 – B LPM – L

0-10 VDC – C Modbus – C RPM – R

None – X Profibus – D psi – P

DeviceNet – E bars – B

None – X kg/cm2 – K

MPa – M

°F – F

°C – CNote: Select one option from each category

Ordering Information:

Power

Display Analog Output Communications Display Units

AC F6600 4-20 mA – A RS232 – A GPM – G DC F6650 0-20 mA – B RS485 – B LPM – L

0-10 VDC – C Modbus – C RPM – R

None – X Profibus – D

DeviceNet – E

None – X Note: Select one option from each category

Ordering Information:

2 3

Ordering Examples:

F6600-X-X-G = AC powered, displays GPM

F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM

F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM

Ordering Examples:

F6700-X-X-G = AC powered, displays GPM

F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM

F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars

Page 14: Turbine Flow Sensors

TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA15

Portable Hydraulic Testers

PFM6Flo-check® DigitalHydraulic Test Unit• Accuracy of ±1%, full range• Turbine flow sensor gives fast

response • Large 3-1/2 digit LCD for both

flow and temperature• Simple operation: one toggle

switch controls power, flowand temperature; load valveoffers fingertip control of pressure to 6000 PSI(41.4 MPa)

• Platinum resistance thermometer, swept wet well;fast and accurate

Compact, lightweight, self-contained portabletester with laboratory accuracy. Designed forfast diagnostic troubleshooting of all types ofmobile or stationary hydraulic systems andcomponents. Makes all flow, pressure and temperature measurements simultaneouslyfrom one point.

Helical type pressure gauge providespulsation dampening and high over-pressurecapacity. Pressure relief disc protection. Low battery/over-range indicators. Metricunits available.

PFM6BDFlo-check®

Bi-DirectionalHydraulic Test Unit• Provides in-line testing of

bi-directional motors, servo systems and valves

• Has the lowest pressure drop of any bi-directional tester

• Same basic features and easeof operation as PFM6 model

Compact, lightweight, self-contained portabletester with laboratory accuracy in either direction. Designed for fast bi-directional diagnostic troubleshooting of all types of mobile or stationary hydraulic systems andcomponents. Makes all flow, pressure and temperature measurements simultaneouslyfrom one point. Helical type pressure gaugeprovides pulsation dampening and high over-pressure capacity. Pressure relief disc protection. Low battery/over-range indicators.Metric units available.

PFM8Flo-check® DigitalHydraulic Test Unit& Dynamometer• Front panel selectable U.S.

or metric readings• Digital pressure to 6000 PSI

(41.4 MPa) • Portable dynamometer reads

power (HP & kW) directly• Large easy-to-use

membrane switch selectsflow, temperature, pressureor power

• Low noise input circuitry provides steadier readingswhen flow is pulsating orcavitating

• Auto/OFF automaticallyturns power off after 5 minutes with no flow signal

All-digital, compact, lightweight, self-contained portable hydraulic tester anddynamometer. Designed for fast diagnostictroubleshooting of all types of hydraulicsystems and components, includingengine-pump combinations. Makes all flow, pressure, temperature and power measurements simultaneously from one point, in either U.S. or metric units (switchable). Silicon strain gauge pressuresensor. Offers other standard features ofPFM6 model.

Page 15: Turbine Flow Sensors

FAX: 1- 800- 245-3569 LEARN ABOUT OTHER D IV IS IONS ’ PRODUCTS 16

Portable Hydraulic Testers

SERIES DIMENSIONS (L x D x H) WEIGHTINCHES LBS (KG) LBS (KG)

PFM6-15 11.3 X 11.0 X 3.5 287 X 279 X 89 13.85 (6.3)PFM6-30 11.3 X 11.0 X 3.5 287 X 279 X 89 13.85 (6.3)PFM6-60 11.5 X 11.0 X 3.5 292 X 279 X 89 16.50 (7.5)PFM6-85 11.5 X 11.0 X 3.5 292 X 279 X 89 16.50 (7.5)PFM6-200 12.3 X 11.8 X 4.0 311 X 298 X 101 20.00 (9.1)PFM6BD-60 11.3 X 11.0 X 4.0 287 X 279 X 101 16.50 (7.5)PFM6BD-85 11.3 X 11.0 X 4.0 287 X 279 X 101 16.50 (7.5)PFM6BD-200 11.8 X 11.5 X 4.5 300 X 292 X 114 19.50 (9.0)PFM8-15 11.3 X 11.0 X 3.5 287 X 279 X 89 13.85 (6.3)PFM8-30 11.3 X 11.0 X 3.5 287 X 279 X 89 13.85 (6.3)PFM8-60 11.5 X 11.0 X 3.5 292 X 279 X 89 16.50 (7.5)PFM8-85 11.5 X 11.0 X 3.5 292 X 279 X 89 16.50 (7.5)PFM8-200 12.3 X 11.8 X 4.0 311 X 298 X 101 20.00 (9.1)

DIMENSIONS

SERIES MODEL NOMINAL FLOW POWERNUMBER PORT SIZE RATE HP (kW)

PFM6-15 F5080 (CE)-XXX SAE 12 1-15 GPMPFM6-30 F5079 (CE)-XXX SAE 12 2-30 GPMPFM6-60 F5078 (CE)-XXX SAE 16 3-60 GPMPFM6-85 F5077 (CE)-XXX SAE 16 4-85 GPMPFM6-200 F5076 (CE)-XXX SAE 24 7-199.9 GPMPFM6-15 F5110 (CE)-XXX G 3/4 4-56 LPMPFM6-30 F5111 (CE)-XXX G 3/4 7.5-113.6 LPMPFM6-60 F5112 (CE)-XXX G 1 12-227 LPMPFM6-85 F5113 (CE)-XXX G 1 15-321 LPMPFM6-200 F5114 (CE)-XXX G 1-1/2 26-757 LPMPFM6BD-60 F5082 (CE)-XXX SAE 16 3-60 GPM / 12-227 LPMPFM6BD-85 F5083 (CE)-XXX SAE 16 4-85 GPM / 15-321 LPMPFM6BD-200 F5084 (CE)-XXX SAE 24 7-199.9 GPM / 26-757 LPMPFM8-15 F5061 SAE 12 1-15 GPM / 4-56 LPM 52.5 (39)PFM8-30 F5058 SAE 12 2-30 GPM / 7.5-113.6 LPM 105 (78)PFM8-60 F5052 SAE 16 3-60 GPM / 12-227 LPM 210 (157)PFM8-85 F5053 SAE 16 4-85 GPM / 15-321 LPM 298 (222)PFM8-200 F5054 SAE 24 7-199.9 GPM / 26-757 LPM 700 (522)

ORDERING INFORMATION

MODEL NOMINAL FLOWNUMBER PORT SIZE RATEF4934-1530 Carrying 15 & 30 GPM / 60 & 113.6 LPMF4934-6085 Cases 60 & 85 GPM / 200 & 321 LPMF4934-200 200 GPM / 757 LPMF1614-6000 Safety Disc 0-6000 PSIF1614-7500 0-7500 PSIF001109 Calibration Five PointF001110 Certificates Ten Point

ACCESSORIES

SPECIFICATIONS:MATERIAL:Housing: 2024-T351 Anodized aluminumTurbine Rotor: T416 Stainless steelRotor Supports: 6061-T6 Aluminum;Rotor Shaft: T303 Stainless steelSeals: Buna N standard; Viton and EPR optionalBall Bearings: 440 C Stainless steelHub Cones: 6061-T6 Aluminum alloyTemperature Probe: 12L14 Steel (Zinc plate, dichromate finish)PFM6/8 SERIES TESTERSValve Body for 15/30’s: cold rolled steel; 60/85/200 Body:12L14Steel Stem – 303 Stainless steelPoppet: 12L14 Steel, HardenedStraightening section: for 15/30 is CA360 Brass; for 60/85/200 is 6061-T6 AluminumCones: 2024-T4 Aluminum200 GPM: Sleeve – D.O.M. steel tubePFM6BD SERIES TESTERSValve: Body - 12L14 SteelSpool/Sleeve: 4340 Alloy Steel, HardenedBy-Pass Plate: 2024-T351 AluminumStraightening section: 6061-T6 AluminumCones: 2024-T4 AluminumPORTS: SAE Straight Thread O-Ring Boss, Female, J1926/1; BSPP ISO1179MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish;

Nut – 12L14 steel, zinc plate, dichromate finishPERFORMANCE:Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.Flow accuracy: ±1% of full scaleRepeatability: ± 0.2%Pressure rating: 6000 psi (414 bar) maximumTurbine response: ≤ 200 msFluid temperature range: -4° to 300° F (-20° to 150° C)Ambient temperature range: -4° to 131° F (-20° to 55° C)Flow readout: linearity and zero shift = +/- 1 digitOperating pressure: to 6000 PSI (414 Bar, 41.4 MPa, 420 kg/cm2)Fluid temperature: to 300 F (150 C)Readout accuracy: +/- 1 digitBattery type: AA size alkaline; Life 50 hours-CE Certified models are available in PFM6 & PFM6BD series units.-XXX-when ordering, please specify P-PSI, B-Bar, M-MPa, K-kg/cm2.Ordering example: FPFM6-200-B-C ordering PFM6-200 w/SAE24 ports, pressure scaled in bar, and CE certified unitFive or Ten Point Calibration Certificates are available and traceable to NIST, ISO 9001 / ANSI Z540-1 & MIL-STD 45662A

For pressure drop information, refer to page 22.

Page 16: Turbine Flow Sensors

TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S17

Sensor Array with Load ValveSeries F6100Simultaneously Measures Flow, Pressure and Temperature

• Four flow ranges• Turbine Flow Measurement • Pressures up to 6000 psi

(414 bar)• Temperatures up to 300° F

(150° C)• Includes Loading Valve

The Sensor Array is used for diagnostic evaluation of hydraulic motors, pumps, valves,hydrostatic drives and cylinders. When performed as part of a routine preventativemaintenance program, catastrophic or untimely repairs are minimized. All that isrequired is to make quick and easy fluid line connections between the sensing arrayand appropriate locations in the hydraulic circuit. The load valve is used to create a restriction so that a relief valve setting or internal leakage of a valve or hydraulic cylinder can be determined. The efficiency of a hydraulic pump or motor can be similarly established and compared to factory specifications.

F6100 series sensor arrays are turbine flow meters equipped with auxiliary pressureand temperature sensors and an internal loading valve. The sensor arrays measureflow, pressure, and temperature simultaneously. Each sensor has a self-contained conditioning circuit that converts raw sensor input to a 4-20 mA output signal suitablefor use with Flo-tech’s SIM-Check system analyzers and XLI and XLF readouts. Theyare also suitable for use with data loggers, strip chart recorders, and control/monitoringdevices such as PCs and PLCs. An optional pulse output for flow measurement is also available.

SPECIFICATIONS:MATERIAL:Housing: 2024-T351 Anodized aluminumTurbine Rotor: T416 Stainless steelRotor Supports: 6061-T6 AluminumRotor Shaft: T303 Stainless steelSeals: Buna N standard; Viton and EPR optionalBall Bearings: 440 C Stainless steelHub Cones: 6061-T6 Aluminum alloyTemperature Probe: 12L14 SteelF6100 SERIES SENSORSValve Body for 15/30’s: cold rolled steel; 60/85/200 Body:12L14 Steel Stem – 303 Stainless steelPoppet: 12L14 Steel, HardenedStraightening section: for 15/30 (60/113.5 GPM) is CA360 Brass; for 60/85/200 (199.9/350/750 LPM) is 6061-T6 AluminumCones: 2024-T4 Aluminum200 GPM: Sleeve – D.O.M. steel tubePORTS: SAE Straight Thread O-RingBoss, Female, J1926/1; BSPP ISO1179MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish;

Nut – 12L14 steel, zinc plate, dichromate finishPERFORMANCE:Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.Flow accuracy: ±1% of full scaleRepeatability: ±0.2%Pressure rating: 6000 psi (414 bar) maximumTurbine response: ≤ 200 MSFluid temperature range: -4° to 300° F (-20° to 150° C)Ambient temperature range: -4° to 131° F (-20° to 55° C)

For pressure drop information, refer to page 22.

Page 17: Turbine Flow Sensors

FAX: 1- 800- 245-3569 CALL TO DISCUSS YOUR SPECIFIC APPLICATION 18

Sensor Array with Load ValveSeries F6100

Simultaneously Measures Flow, Pressure and Temperature

ORDERING INFORMATION:

PRESSURESENSOR PORTS

TEMPERATURE SEALSFLOWTRANSDUCER

MODELNUMBER

SealsB Buna NV VitonE EPR

( Example ) F6154 – A B - T 6

Temperature Transducer Output: 4-20 mAT with SensorG G 1/4 (F) PluggedO SAE #2 (J514) Plugged

Pressure Transducer Output: 4-20 mA1 1000 psi (69 bar) Sensor3 3000 psi (207 bar) Sensor6 6000 psi (414 bar) SensorG G 1/4 (F) PluggedO 1/4 NPTF (J514) Plugged

FLOW RATENOMINALPORT SIZE

F6150F6153F6156F6159F6161F6163F6165F6167

1 - 15 GPM2 - 30 GPM4 - 85 GPM

7 - 199.9 GPM4 - 56 LPM

7.5 - 113.6 LPM15 - 321 LPM26 - 757 LPM

SAE 12SAE 12SAE 16SAE 24G 3/4G 3/4G 1G 1-1/2

BA T 6

Flow TransducerA 4-20 mA OutputF Frequency Output

Ordering Example:F6154-AB-T6, SAE #16, 3-60 GPM with 4-20 mA flow transducer, 4-20 mA temperature transducer & 6000 psi pressure sensor with 4-20 mA electrical output.

Five or Ten Point Calibration Certificates are available. Flo-tech P.N. Description F001109 Five Point Calibration Certificate F001110 Ten Point Calibration Certificate

SIM™ SENSOR ARRAY WITH LOAD VALVE

F6150-AB-T1F6150-AB-T3F6150-AB-T6F6153-AB-T1F6153-AB-T3F6153-AB-T6F6156-AB-T1F6156-AB-T3F6156-AB-T6F6159-AB-T1F6159-AB-T3F6159-AB-T6F6161-AB-T1F6161-AB-T3F6161-AB-T3F6163-AB-T1F6163-AB-T3F6163-AB-T6F6165-AB-T1F6165-AB-T3F6165-AB-T6F6167-AB-T1F6167-AB-T3F6167-AB-T6F6162F6233F1614-6000F1614-7500

Turbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorTurbine-type Flow Block with Active Magnetic (Flow)Transducer, Active Pressure Transducer andActive Temperature SensorCable, Sensor Array (with 3 Female Connectors) 30 ft.Cable Auxiliary (with single Female Connector) 30 ft.Safety Disc, 6000 PSISafety Disc, 7500 PSI

0-1K PSI0-3K PSI0-6K PSI0-1K PSI0-3K PSI0-6K PSI0-1K PSI0-3K PSI0-6K PSI0-1K PSI0-3K PSI0-6K PSI0-69 BAR0-207 BAR0-414 BAR0-69 BAR0-207 BAR0-414 BAR0-69 BAR0-207 BAR0-414 BAR0-69 BAR0-207 BAR0-414 BAR

SAE 12SAE 12SAE 12SAE 12SAE 12SAE 12SAE 16SAE 16SAE 16SAE 24SAE 24SAE 24G 3/4G 3/4G 3/4G 3/4G 3/4G 3/4G 1G 1G 1G 1-1/2G 1-1/2G 1-1/2

1-15 GPM1-15 GPM1-15 GPM2-30 GPM2-30 GPM2-30 GPM4-85 GPM4-85 GPM4-85 GPM7-199.9 GPM7-199.9 GPM7-199.9 GPM4-56 LPM4-56 LPM4-56 LPM7.5-113.6 LPM7.5-113.6 LPM7.5-113.6 LPM15-321 LPM15-321 LPM15-321 LPM26-757 LPM26-757 LPM26-757 LPM

PARTNUMBER

ITEMDESCRIPTION PORTS FLOW PRESSURE

ACTIVA™ AUXILIARYPRESSURE SENSORS WITH 4-20mA

F6301-15F6301-30F6301-60F6301-100F6301-150F6301-200F6301-300F6301-500

0-15 0-1.0350-30 0-2.070-60 0-4.140-100 0-6.90-150 0-10.350-199 0-13.800-300 0-20.700-500 0-34.5

PARTNUMBER

PRESSUREPSI BAR PORTS

1/4NPTMale

F6301-750F6301-1KF6301-2KF6301-3KF6301-5KF6301-7.5KF6301-10KF6301-15K

0-750 0-51.750-1000 0-690-2000 0-1380-3000 0-2070-5000 0-3450-7500 0-517.50-10,000 0-6900-15,000 0-1035

PARTNUMBER

PRESSUREPSI BAR PORTS

1/4NPTMale

ACTIVA™ AUXILIARY RTD TEMPERATURE SENSORS WITH 4-20mA

F6310

F6233

Temperature Sensor, -40° to 350° F, Thread-5/16-24 UNF-2B, suitable forSAE J1926-2 O-Ring Boss (SAE #2)Cable, Auxiliary (with Female Connector) 30 ft.

PARTNUMBER ITEM DESCRIPTION

Page 18: Turbine Flow Sensors

FAX: 1- 800- 245-3569 LEARN ABOUT OTHER D IV IS IONS ’ PRODUCTS 22

F6100 & PFM SeriesPressure Drop Information

PFM6BD-85 FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 10 20 30 40 50 60 70 80 90 100GPM

PS

I

FORWARD

REVERSE

PFM6BD-200 FLOW VS PRESSURE DROP

0

15

30

45

60

75

90

105

120

135

150

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220GPM

PS

I

FORWARD

REVERSE

FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 5 10 15 20GPM

PS

I

PFM6-15F6150F6161

FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 10 20 30 40GPM

PS

I

PFM6-30F6153F6163

FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 10GPM

PS

I

PFM6-60

20 30 40 50 60 70

FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 10 20 30 40 50 60 70 80 90 100GPM

PS

I

PFM6-85F6156F6165

FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

0 20 40 60 80 100 120 140 160 180 200 220GPM

PS

I

PFM6-200F6159F6167

PFM6BD-60 FLOW VS PRESSURE DROP

0

20

40

60

80

100

120

140

160

180

200

220

0 10 20 30 40 50 60 70GPM

PS

I

FORWARD

REVERSE

Page 19: Turbine Flow Sensors

TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S23

F6301 Pressure SensorWith 4-20 mA Output

• 4-20 mA electrical output• Long-term stability & repeatability• Wide range of pressures available• Stainless steel NEMA 4X

enclosure

The F6301 Pressure Sensors utilize polysiliconestrain resistors to create very low noise levelswith very high signal output. The metaldiaphragm and polysilicone bridge are unaffected by shock, vibration or mounting position.

These sensors are ideal for any applicationwhere measuring pressures are required.

SPECIFICATIONS:OVERPRESSURE: Full scale in PSI

0-15 to 0-3000 to 0-7500 to0-2000 0-5000 0-15,000

Proof 200% 150% 120%Burst 800% 300% 150%ACCURACY: ± 1% of full scaleNon-Linearity: ±0.7%Hysteresis: ±0.2%Non-repeatability: ±0.07%DURABILITY: 108 cycles 20/80% full scale with negligible performance changeRESPONSE TIME: < 5msENVIRONMENTAL EFFECTS:Humidity: No performance effect at 95% relative humidity-noncondensingPosition Effect: < 0.01% full scale TEMPERATURE:Storage: -65° to +250° F (-54° to 121° C)Operating: -20° to +180° F (-29° to 82° C)Compensating: -20° to +160° F (-29° to 71° C)

Bulletin #514

PRESSURE RANGES

Part No. PSI BAR kg/cm2 PortsF6301-15 0 - 15.00 0 - 1.034 0 - 1.055F6301-30 0 - 30.0 0 - 1.999 0 - 1.999F6301-60 0 - 60.0 0 - 4.13 0 - 4.22F6301-100 0 - 100.0 0 - 6.89 0 - 7.03F6301-150 0 - 150.0 0 - 10.34 0 - 10.55F6301-200 0 - 200 0 - 13.78 0 - 14.06F6301-300 0 - 300 0 - 19.99 0 - 19.99 1/4F6301-500 0 - 500 0 - 34.5 0 - 35.1 NPTF6301-750 0 - 750 0 - 51.7 0 - 52.7 MaleF6301-1K 0 - 1000 0 - 68.9 0 - 70.3F6301-2K 0 - 2000 0 - 137.8 0 - 140.6F6301-3K 0 - 3000 0 - 199.9 0 - 199.9F6301-5K 0 - 5000 0 - 345 0 - 351F6301-6K 0 - 6000 0 - 414 0 - 422F6301-7.5K 0 - 7500 0 - 517 0 - 527F6301-10K 0 - 10,000 0 - 689 0 - 703F6301-15K 0 - 15,000 0 - 1034 0 - 1055

Page 20: Turbine Flow Sensors

FAX: 1- 800- 245-3569 CALL TO DISCUSS YOUR SPECIFIC APPLICATION 24

F6301 Pressure SensorWith 4-20 mA Output

SPECIFICATIONS (cont.):THERMAL COEFFICIENTS (68° F ref.) % full scale / ° FStandard:Zero: ±0.04%Span: ±0.04%VIBRATION SWEEP: < ±0.1% full-scale effect for 0-2000 Hz at

20 g’s in any axisSHOCK: < ±0.5% full-scale effect for 100 g’s, 20 ms shock in any axisELECTRICAL:Output Signal: 4-20 mA (2 wire)

POWER REQUIREMENTS: 10-36 V DC unregulated 4-20 mA,reverse polarity protected.CIRCUIT TO CASE INSULATION RESISTANCE:100 M ohms @ 50 VdcPHYSICAL:Enclosure: NEMA 4XWeight: 2 oz. (approximate without cable)MATERIALS:Case: 300 series stainless steelCable: No. 24 AWG, 36" PVC, shielded, vented, UL approved.Diaphragm: 17-4 PH stainless steelConnections: 1/4 NPT maleThese pressure sensors are compatible with Flo-tech’s XLI Digitaldisplays (page 11) and F6234-6, 6-ft. or F6234-15, 15-ft. connecting cables. (page 27).

3234CABLES

PAGE21ACTIVA FLOW SENSORS

PAGETEMPERATURE SENSORS

PAGEXLI DIGITAL DISPLAYS

PAGE 11 3 26 27

Load Limitations 4-20mA Output Only

LOOP SUPPLY VOLTAGE (VDC)

V min = 10V = (.022A x RL)RL = RS = RW

RL = LOOP RESISTANCE (ohms)RS = SENSE RESISTANCE (ohms)RW = WIRE RESISTANCE (ohmns)

1182

1000

750

500

250

0

(R LOOP)

0 10 20 30 36

4.00"(102mm)

CABLE 3 ft. (.91m)

2.70"(69mm)

.85"(22mm)

5/8" Hex

1 - N/C2 - SIGNAL OUTPUT3 - +VDC3

21

Page 21: Turbine Flow Sensors

25

SPECIFICATIONSExternal Power:Input Voltage 8.5 to 30 VDC, diode protectedMaximumCurrent Draw 18 mA, using internal resistor @ 30 VDC input

Inputs: Magnetic pick-upFrequency Range 0-4000 HzTrigger Sensitivity 30 mV p-p to 30 V p-p

Output Signal: 30 VDC max voltage (open collector transistor) 0.25 W max power Pulse type, using internal pull-up resistor; V

H = power input voltage - 0.7 VDC

VL = less than 0.4 V @ max input power

Pulse type, using external pull-up resistor; V

H = input voltage to external pull-up resistor

VL = [V

H /(selected resistor value + 47Ω)] × 47Ω

Pulse length; 150μs, 1ms, 25ms, 100ms, 500ms, 1s or auto mode selectable

Internal Pull-upResistor: Jumper disable option 3.6K Ohm

OperatingTemperature: -22 to +158 °F (-30 to +70 °C)

Enclosure: UL 94-5VA fl ame retardant ABS with mounting fl anges

Pre-amplifi er for low level turbine meter• Interface for pulse output devices to PLC, RTU, PC • data acquisition card or similar devicesScale turbine meter output to desired engineering units• On board microcontroller• Internal or external pull-up resistor • Compact ABS enclosure with mounting fl anges• Field adjustable (with optional software)• K-factor range 1- 999,999,999•

The K-Factor Scaler is a fi eld adjustable frequency divider that converts the low level frequency output from a turbine meter into a scaled square wave output signal. This amplifi ed, square wave output signal will interface with any frequency or counter input data collection device.

Due to the low level frequency signal of the FSC-375 and the Ultima F6202-F and F6222-F series turbine meters, the K-Factor Scaler is required to amplify the signal of these turbine meters for transmission to the Flo-tech F6600 and F6650 Series digital displays.

The K-Factor Scaler is also capable of converting the frequency output of a turbine meter into a different frequency, representing another unit of measure, such as liters, barrels, cubic feet, etc. This requires the optional programming software kit and the K-factor information unique to the turbine meter.

K-Factor ScalerFrequency Divider

ORDERING INFORMATION

DIMENSIONS - Inches (mm)

MODEL PART NUMBERK-Factor Scaler F5140

Programming Software Kit F5141

Fax 800-245-3569DEPENDABLE CUSTOMER SERVICE

Page 22: Turbine Flow Sensors

FAX: 1- 800- 245-3569 26F IVE OR TEN PO INT CAL IBRAT ION AVA ILABLE

2.81"(72mm)

3.41"(87mm)

.85"(22mm)

3 12

0.25" (6.4mm)

CABLES

PAGE ACTIVA FLOW SENSORS

PAGE 3PRESSURE SENSORS

PAGE 23 27 XLI DIGITAL DISPLAYS

PAGE 11

F6310Temperature Sensors

With 4-20 mA Output

• RTD Temperature element• 4-20 mA electrical output• Temperatures up to 350° F• Withstand pressures up to

6000 PSI

These two-wire platinum RTD (resistance temperature dector) sensors with 4-20 mA output are designed for direct insertion into highpressure fluid systems without need for specialpressure fittings. They are ideal for indicating system operating conditions, temperature testingand process measurements and control.

SPECIFICATIONS:TEMPERATURE RANGE:Ambient: -40° to +350° F (-40° to +177° C)Fluid: -4° to +350° F (-20° to +177° C)Dedicated Input and Span Range: -40° to +350° F (-40° to +177° C)ACCURACY: Chart ACURRENT SPAN RANGE: 4-20 mARESPONSE TIME: 3 secondsMAXIMUM PRESSURE: 6000 PSI (414 Bar, 422 kg/cm2)OPERATING LOOP VOLTAGE:Minimum: 9V + Voltage of load resistor at 20 mAMaximum: 28VMinimum Load Resistance: 10 ohmsMaximum Load Resistance: Loop Voltage – 9V

(including wiring losses) 20 mAOhms

Compatible with Flo-tech XLI Digital display (page 11) and connecting cable, F6234-15, 15-ft. cable (page 27)

Combined Celsius FahrenheitCelsius/Fahrenheit Only Only

Temperature Accuracy Temp. Accuracy Temp. Accuracy-40° C -40° F ±0.8° C -40° C ±0.8° C -40° F ±1.4° F

0° C +32° F ±0.6° C 0° C ±0.6° C 0° F ±1.2° F+100° C +212° F ±1.2° C +50° C ±0.9° C +50° F ±1.2° F+176° C +350° F ±1.7° C +100° C ±1.2° C +100° F ±1.5° F

– – – +150° C ±1.5° C +200° F ±2.1° F– – – +176° C ±1.7° C +300° F ±2.7° F– – – – – +350° F ±3.0° F

CHART A

5/16-24 UNF-2BSuitable for

SAE J1926-2O-Ring Boss

(SAE #2)Pin Configuration1 Case Ground2 Signal3 + Voltage

Bulletin #515

Page 23: Turbine Flow Sensors

28

Flo-tech offers a complete selection of mating cables to complete your hydraulic measurement system.

To select the appropriate cable for your application, refer to the Connecting Cable Charts shown below and on the next page.

Cables

Sensor Model Connecting Cable Connecting EndsSignal

Amplifi erDigital Display

FR

EQ

UE

NC

Y

FSC-375F2832-6, 6 ft orF2832-15, 15 ft

MS female to tinned leads

F5140K-Factor Scaler

F6600 / F6650 Series

FSC-500

F2832-6, 6 ft orF2832-15, 15 ft

2-Pin (MS) female totinned leads

—F6600 / F6650 Series

or HB2800 Series

FSC-750

FSC-1000

FSC-1005

FSB-1250

FSB-1500

FSD-1250

FSD-1500

FSD-2000

F6202-F / F6222-FF6234-6, 6 ft orF6234-15, 15 ft

3-Pin female totinned leads

F5140K-Factor Scaler

F6600 / F6650 Series or HB2800 Series

F6204-F / F6224-FF6234-6, 6 ft orF6234-15, 15 ft

3-Pin female totinned leads

— F6600 / F6650 SeriesF6206-F / F6226-F

F6208-F / F6228-F

AN

AL

OG

FSC-375 with IFC

F6557-6, 6 ft orF6557-15, 15 ft

5-Pin female to tinned leads

— F6700 / F6750 Series

FSC-500 with IFC

FSC-750 with IFC

FSC-1000 with IFC

FSC-1005 with IFC

FSB-1250 with IFC

FSB-1500 with IFC

FSD-1250 with IFC

FSD-1500 with IFC

FSD-2000 with IFC

F6202-AI / F6222-AIF6202-AV / F6222-AV

F6557-6, 6 ft orF6557-15, 15 ft

5-Pin female to tinned leads

— F6700 / F6750 Series

F6204-AI / F6224-AIF6204-AV / F6224-AV

F6206-AI / F6226-AIF6206-AV / F6226-AV

F6208-AI / F6228-AIF6208-AV / F6228-AV

F6301-X(Pressure Sensors)

F6234-6, 6 ft orF6234-15, 15 ft

3-Pin female totinned leads

— F6700 / F6750 Series

F6310(Temperature Sensor)

F6234-6, 6 ft orF6234-15, 15 ft

3-Pin female totinned leads

— F6700 / F6750 Series

Tel 800-433-5263 MEASURE SYSTEM PERFORMANCE

Page 24: Turbine Flow Sensors

28 FAX: 1- 800- 245-3569

* Centipoise are given for oil of 0.876 specific gravity. Relationship: centistokes X specific gravity = centipoise

To Convert Into… Multiply by…Barrel (U.S. liquid) Gallons 31.5Bars Kgs/sq meter 10,200Bars Pounds/sq in 14.50Centigrade Fahrenheit (C° x 9.5) +32Cubic centimeters Cu feet .00003521Cubic centimeters Cu inches 0.06102Cubic centimeters Cu meters .000001Cubic centimeters Gallons (U.S. liquid) .0002642Cubic centimeters Liters 0.001Cubic feet Cu cms 28,320Cubic feet Cu inches 1,728Cubic feet Cu meters 0.02832Cubic feet Gallons (U.S. liquid) 7.48052Cubic feet Imperial gallons 6.23210Cubic feet Liters 28.317Cubic feet/min Cu cms/min 28,317Cubic feet/min Gallons/min 7.481Cubic feet/min Liters/min 28.32Cubic feet/sec Gallons/min 448.83Cubic inches Cu cms 16.39Cubic inches Cu feet .0005787Cubic inches Cu meters .00001639Cubic inches Gallons (U.S. liquid) .004329Cubic inches Imperial gallons .0036065Cubic inches Liters 0.01639Cubic meters Cu cms 1,000,000Cubic meters Cu feet 35.31Cubic meters Cu inches 61,023Cubic meters Gallons (U.S. liquid) 264.2Cubic meters Liters 1,000Degree Fahrenheit Degree Celsius t° C = (t° F – 32)/1.8Feet/min Cms/sec 0.5080

To Convert Into… Multiply by…Feet/min Meters/min 0.3048Gallons/min Cu cms/min 3,785.412Gallons/min Cu feet/min .1337Gallons/min Liters/min 3.785Imperial gallons Cu feet .160459Imperial gallons Cu inches 277.274Imperial gallons Liters 4.54374Imperial gallons U.S. gallons 1.20032Kilograms/sq cm Pounds/sq ft 2,048Kilograms/sq cm Pounds/sq in 14.22Kilograms/sq meter Bars .00009807Kilograms/sq meter Pounds/sq in .001422Liters Cu cm 1,000Liters Cu feet 0.0353145Liters Cu inches 61.0234Liters Cu meters 0.001Liters Gallons (U.S. liquid) 0.264170Liters Imperial gallons .220083Liters/min Cu cms/min 1000Liters/min Cu feet/min .035Liters/min Gallons/min .264Pascal (Pa) Bar .00001Pascal (Pa) Pounds/sq in .000145Pounds/sq inch Kgs/sq meter 703.1Pounds/sq inch Pascal (Pa) 6,895Pounds/sq inch Bar .069U.S. gallons Imperial gallons .83267U.S. gallons Cu cms 3785U.S. gallons Cu feet .133681U.S. gallons Cu inches 231U.S. gallons Cu meters .3785U.S. gallons Liters 3.785

Viscosity Conversion TableSaybolt Universal

Seconds (SSU) ISO-VG CentiStoke CentiPoise* Typical Brands/Liquids at 100° F31 2 1.0 0.876 Water35 3 2.5 2.19 –40 5 4.2 3.68 –45 5/7 5.9 5.17 –50 7 7.5 6.57 Kerosene55 7/10 8.8 7.71 Atlantic Richfield/Duro 55 Hyd. Oil60 10 10.5 9.20 Monsanto/Skydrol - 500 A70 10/15 13.2 11.56 Mobil/Aero HFA Hydraulic Oil80 15 15.7 13.75 No 4 Fuel Oil90 22 18.2 15.94 Stauffer Chemical/Fyrquel 90100 22 20.6 18.05 Conoco/Syncon Synthetic AW Hyd. Oil150 32 32.0 28.03 Mobile/DTE 24 Hydraulic Oil200 46 43.2 37.84 Citco/Glycol FR-40XD (Oil in Water)300 68 65.0 56.94 SAE 20 Crankcase Oil400 68/100 86.0 75.34 Sunoco/Sunvis 41 Hydraulic Oil500 100 108 94.61 SAE 30 Crankcase Oil750 150 162 141.91 SAE 40 Crankcase Oil1000 220 216 189.22 Mobil/Paper Machine Oil - Type K1500 320 323 282.95 SAE 50 Crankcase Oil2000 460 431 377.56 Amoco/American Industrial Oil - No. 4603000 680 648 567.65 SAE 140 Gear Oil4000 1000 862 755.11 SAE 250 Gear Oil

Common Conversions

Page 25: Turbine Flow Sensors

TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA29

Notes

Page 26: Turbine Flow Sensors

30

DIVISION OF RACINE FEDERATED, INC. 2200 SOUTH STREET – RACINE, WI 53404 – TEL. (262) 639-6770

Flo-techby

®

Page 27: Turbine Flow Sensors

Hedland® Flow MetersHedland offers over 7000 in-line, direct reading flowmeters with an accuracy of ±2% of full scale. Thisunique spring loaded variable-area design allows for installation in any position without affecting theaccuracy. The meters can be installed quickly withoutcostly flow straighteners or other special plumbing requirements. Available in Aluminum, Brass andStainless from 1/4" to 3" NPTF, SAE and BSP portsizes. These meters are ideal to monitor a wide rangeof liquids and gases including aggressive chemicals,under a wide range of pressures, temperatures and rigorous conditions encountered in industrial applications. For more information, refer to theHedland Flow Meter catalog, form #140-2G

EZ-View® Flow MetersFeaturing Hedland‘s unique spring loaded variable-areadesign. EZ-View meters can be installed in any positionwithout affecting accuracy. They can be installed quicklywithout costly flow straighteners or other special plumbing requirements. These meters operate within±7% accuracy and are constructed of Polysulfone plastic. Available in 1/2, 3/4 & 1" NPTF or 3/4" & 1"brass and PVC sweat fittings. An optional AC or DCFlow-Alert flow-switch automatically signals alarms ifflow is too high or too low. For more information, refer to the EZ-View Flow Meter catalog, form #239.

Flo-tech Hydraulic Diagnostic ProductsFlo-tech offers a line of hydraulic diagnostic products to assist in troubleshooting all types of hydraulic systems. Portable Hydraulic Testers are designed to monitor flows to 200 GPM (750 LPM), pressures to 6,000 psi (413 bar) and temperatures to 300°F (149°C). These portable battery-operated testers are available in a variety of flow ranges and port sizes. For more information, refer to the Flo-tech New Generation Portable Hydraulic Tester catalog, form #208 and the SIM Check Portable Hydraulic System Analyzer catalog, form #507.

If you have any questions or would like to receive literature on any of the above product lines, please feel free to contact one of our Customer ServiceRepresentatives by telephone at (262) 639-6770/(800) 433-5263 or by telefax at (262) 639-2267/ (800) 245-3569 or visit our Web site: www.hedland.com

Flo-tech

by ®

Form No. 300 8/01

MAILING ADDRESS SHIPPING ADDRESSP.O. BOX 1405 2200 SOUTH STREETRACINE, WI 53401 RACINE, WI 53404

TELEPHONE: FAX:(262) 639-6770 (262) 639-2267

DISTRIBUTED BY:


Recommended