+ All Categories
Home > Documents > Turnkey Solutions for Radiation I Protection in PET Laboratories T … · 2015. 3. 19. ·...

Turnkey Solutions for Radiation I Protection in PET Laboratories T … · 2015. 3. 19. ·...

Date post: 26-Jan-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
9
RADIATION PROTECTION Turnkey Solutions for Radiation Protection in PET Laboratories
Transcript
  • RA

    DI

    AT

    IO

    NP

    RO

    TE

    CT

    IO

    N

    Turnkey Solutions for Radiation

    Protection in PET Laboratories

  • Berthold Technologies has more than 60 years experience in manufacturing radiation protection measuring systems. We

    provide a comprehensive range of monitoring and control systems for radiation protection in PET facilities including

    survey monitors, neutron monitors, installed and portable gamma dose rate, activity in room air and stack emission

    systems.

    Continuous measurement of gamma dose rate in each room together with unique gamma insensitive positron detectors

    for localisation of room air activity ensures personnel are always informed of the levels of each type of radiation. Alarm

    levels can be defined for each room based on gamma dose rate or activity in air levels, the acoustic and visual alarms

    being located local to the detector or relayed to a central area.

    Our unique large area positron detectors are typically built into the ventilation ducts eliminating the requirement for

    offline sampling pumps ensuring maintenance free operation.

    Stack emission of radioactivity is also possible using high efficiency positron sensitive detectors with a typical installation

    having a minimum detectable limit of 80 to 100 Bq/m3.

    A number of data acquisition systems are available depending on the requirements of the facility. Berthold brings

    experience from more than 100 reference PET facility monitoring projects around the world.

    Berthold engineer installing a stack

    monitor at a PET facility

    Gamma Dose Rate Monitoring

    Installed Gamma dose rate room monitoring

    Hot Cell interlocking

    Cyclotron Vault interlocking

    Activity in Air Monitoring for Rooms and Stack Emission

    Room air monitors optimised for positron emission detection for

    localisation of activity in air releases

    Monitors for stack release with highest sensitivity

    Data Acquisition, Visualisation, Archiving & Reporting

    Centralised data station, PC or SCADA options

    Local and distributed alarm beacons

    Remote display of key data on touch screens

    Installation, Calibration and service

    Full service support from factory trained engineers

    QC Equipment

    Radio-HPLC detectors for QC

    NaI Gamma Spectroscopy system for QC

    Contamination, Exit and Portable Dose Rate Monitors

    Portable Contamination Monitors

    Portable Gamma dose rate monitors

    Portable Neutron dose rate monitors

    Hand and Foot Monitors

    Exit Monitors

    Berthold has installed radiation monitoring

    systems for more than 100 PET facilities

    Worldwide

  • Gamma Dose Rate Monitoring

    for room monitoring, hot cell interlocking and vault door interlock

    Berthold offers a full range of compensated Gamma dose rate probes to provide monitoring from 50nSv/h up to 103 Sv/

    h.

    Wall or ceiling mounted GM probes are typically used for room area monitoring. For hot cells we offer both ion chambers

    for high dose rate applications and GM detectors as required. Special miniaturised versions of the GM detectors are

    available with separate electronics positioned outside the hot cells to prevent radiation damage and allow installation

    into confined spaces such as transfer cells.

    Suitable electronics are provided to display the live dose rate values, and switch relays for alarms and interlock signals.

    A full cyclotron vault door interlock system can be integrated with the radiation monitoring system to include

    measurement from the Gamma dose rate probe, round clearance system, Castell key system, beam interlock, Rf and

    magnet on and beam on with graphic status display on the PC. The system is fail safe providing interlocking in the

    event of power failure, high dose rate, probe failure or other system malfunction.

    LB6500-4-H10 GM detector

    100nSv/h to 10mSv/h, 65keV to 1.3MeV

    LB6500-3-H10 GM detector

    1uSv/h to 1Sv/h, 65keV to 1.3MeV

    LB6701-H10 ion chamber

    1mSv/h to 1000Sv/h, 45keV to 1.3MeV

    PTB Type Tested

    Hot cell & vault door interlocks, including fail safe

    interlock with automatic detection of probe failure.

    LB6500-4

    LB6500-3

    Local display of dose

    rate values for each

    probe.

  • Activity in Air Monitoring for Rooms and Stack Emission

    Berthold provides unique large area positron sensitive detectors with low sensitivity to ambient gamma radiation. The

    low gamma sensitivity and high positron efficiency allows any release of gaseous radioactivity to be instantly detected

    and localised within the facility.

    In areas of very high ambient gamma backgrounds (for example in production areas handling several GBq of activity)

    detectors can be configured in anti-coincidence to eliminate the response to the 511keV emission resulting in a

    measurement of only the localised positrons in air.

    The detectors are typically mounted within the ventilation ducts whose dimensions define the effective volume of the

    detector. The effective detector volume is therefore very large leading to extremely low detectable limits. A particular

    advantage of this arrangement is the elimination of sampling pumps which are required for off-line measurements.

    Sampling pumps require high maintenance and very secure sampling lines since any activity escaping from these lines

    may not be detected as the activity released will not reach the detectors.

    For room monitoring large area rod detectors are flange mounted inside the ventilation ducts providing immediate

    alarms for localised activity in air releases.

    1000cm2 flat detector versions are used for the stack emission monitor to obtain minimum detection limits in the order

    of 80 to 100Bq/m3 which is unmatched by alternative detector technologies.

    If the design of the ventilation system of the facility makes installation of in-line detectors impossible Berthold can

    provide off-line versions of these detectors but the recommended option is always in-line detectors.

    LB6365 duct detector configuration for

    room air monitoring.

    Detector volume example

    These detectors are typically used to detect

    immediate accidental release of activity into

    a room (for example from a broken vial,

    target breakdown in the cyclotron vault or

    leak from hot cell)

    High sensitive positron detector

    Large detector volume by using existing ventilation

    duct as integral part of the detector.

    No sampling pumps required, detector uses facilities

    normal ventilation system air flow

    Low maintenance as no sampling pump

    Teflon coated detector to eliminate plate out of FDG

    Low gamma sensitivity allowing localisation of air

    release in high ambient gamma areas

    Gamma compensation arrangements for

    exceptionally high ambient gamma areas (eg

    unshielded QC samples)Typical mounting arrangement of the LB6365 in a

    300mm diameter ventilation duct.

  • Activity Stack Emission

    The Euratom recommendations 96/29 and 97/43 and ICRP60 have been adopted into local laws and regulations in each

    country. The requirement to monitor the total emission of radioactivity from a PET facility is dictated by the requirement

    to ensure the effective dose burden to the General Public remains below the specified level. For the UK IRR99 specified

    1mSv/yr level whereas the German regulations specify 0.3mSv/yr (less than medium fluctuation due to natural Radon

    exposure of 2,4 mSv/Yr and below the EU basic standard of 1 mSv/Yr ).

    This translates into maximum release rates for different isotopes. Short lived isotopes have the highest permissible

    levels however the elimination rate from the lungs is also considered. For example in Germany the release of a F-18

    compound with fast lung elimination would have a maximum limit of 4.5 10³ Bq/m³ (F) compared to 2.1 10³ Bq/m³ (S)

    when elimination is slow.

    This consideration results in the Environmental Agency requiring facilities to monitor and record the amount of

    radioactive emissions from a facility and will indeed require the operator to obtain a licence for a specified release having

    a defined limit per day.

    In order to comply with the regulations a stack emission detector is required with high sensitivity to enable accurate

    quantification of the activity released. An accurate measurement of the air flow in the stack is also required and is

    supplied as part of our system.

    LB6377 Stack emission detector

    Large area (1000cm2) positron sensitive

    detectors, gamma insensitive.

    Detector response is independent of temperature

    between –15oC and +45oC.

    MDA typical

  • Data Acquisition, Visualisation, Archiving and Reporting

    A number of data acquisition, alarm and control systems are available depending on the requirements of each facility.

    The LB112 can provide individual measuring stations for a pair of detectors with display of instantaneous radiation

    levels together with multiple local and/or alarm outputs. The alarm relays can also be used for hot cell interlock

    purposes.

    A multichannel data logger, LB9000 provides a central station connected to multiple probes within the facility. The

    multichannel system provides trend graphics for all of the connected probes together with daily release values from a

    stack detector. For smaller installations the 6 radiometric channel LB5340 can be used.

    For long term data archiving the above systems can be linked to the Windows based MEVIS PC software. MEVIS provides

    a full database of all the radiological measurements, historical and active alarms together with flexible reporting which is

    especially important for stack release data. Multiple systems can be linked via RS232/485 or Ethernet.

    For an even greater degree of facility monitoring we offer a full System Control and Data Acquisition (SCADA) system.

    This system provides full data collection from all the measurement detectors and integrates other building signals such

    as cyclotron status, vault door interlocking, hot cell interlocks, ventilation status of each room/hot cell. Each room of the

    facility is graphically shown, together with the detector values and alarm status. A number of remote touch screen

    displays located throughout the building allows personnel to view activity levels and various building status signals from

    remote locations.

    The LB112 allows connection of two probes (for example LB6500

    Dose rate probe and LB6535 Activity in Air probe) and provides a

    visual display of the live measurement.

    The alarm beacon can be mounted on the enclosure, as shown, or

    remote as required.

    A number of LB112s can be networked with a central archiving

    software (MEVIS or SCADA).

    Multiple alarm relays are provided for each measuring channel

    allowing the unit to directly activate interlock signals.

    The LB9000 allows multiple detectors to be connected directly

    to a central location.

    The system is modular allowing configuration for the required

    number of probes and alarm/interlock relays as the facility

    requires.

    The built-in display allows graphic representation of the

    radiometric data.

    Reports can be generated automatically such as daily stack

    release data.

    For data archiving the system can be interfaced directly with

    MEVIS.

    The LB9000 offers an intermediate solution to a full SCADA

    system.

  • Data Acquisition, Visualisation, Archiving and Reporting

    MEVIS provides a Windows PC based software for visualisation of the radiological data in real time and from a historical

    database. Alarm status is also archived allowing a full history of the facility’ status to be recalled.

    A single page graphic of the building is provided with a summary overview of the dose rates and activity in air status

    for the facility. Individual detector time trend graphics are provided together with accumulated release values and air

    flow rates from the stack release monitor.

    Alarms can be defined within MEVIS to alert the user of an accidental release of activity or if they are approaching the

    daily authorisation activity limit. Full reporting of the released activity is provided.

    Berthold also offers a full System Control and Data Acquisition (SCADA) for PET facilities. By using a SCADA system

    Berthold can provide a fully integrated solution for radiation monitoring application.

    The SCADA system allows multiple input and output signals to be combined with the radiological measurement data. All

    probes are directly connected to either one or multiple “Nodes” located in the building, the Nodes are then connected

    via Ethernet to a central SCADA PC running industry standard application software specifically configured for the

    application. Additional signals can be integrated with the measurement, such as the status of ventilation systems,

    cyclotron (Rf, beam on, magnet on), hot cell door interlock , vault door interlock. Having all this information correlated

    in a single database provides greater insight into the facility’s operation.

    MEVIS Central station screen display of radiometric

    data from four probes within a PET facility.

    Displays include building graphic summary, trend

    displays, alarm status (both live and historical),

    accumulated stack release activity as an amount and

    as a percentage of daily authorisation.

    Alarms can be provided locally or at the central MEVIS

    station.

    MEVIS Central Station

    MEVIS can connect to multiple

    data loggers such as the LB112

    and LB9000 and provides full

    archiving of the radiological

    measurements.

  • QC Equipment

    Berthold offers two radio-HPLC detector models which can be used in the PET QC laboratory. Additionally a NaI

    Gamma Spectrometer is available to check for isotope purity.

    The radio-HPLC detectors can be supplied with the Berthold RadioStar PC software or can be linked directly to the

    customers HPLC data station. The LB2045 Gamma Spectroscopy system can be linked directly to a printer for

    hardcopy spectra and reports or connected to a PC spectroscopy software including data storage.

    LB513 High sensitivity Radio-HPLC detector with coincidence

    counting and luminescence subtraction.

    Touch screen display for ease of operation

    Automatic cell identification

    Built in leak detection

    Integrated multi channel analyser

    Built in QC performance tests

    Available with Berthold RadioStar software or with external output to

    other HPLC software (eg Chromeleon)

    Unique flow cells optimised for PET isotopes with high positron

    efficiency and virtually no background from 511keV gamma

    LB500 Radio-HPLC detector

    NaI detector version with lead shielding for all Gamma

    isotopes.

    Special PET version with unique positron sensitive flow cell/

    detector configuration which virtually eliminates

    background influence from 511keV gamma emission even

    without lead shielding.

    LB2045 Gamma Spectrometer

    NaI detector options include well

    crystal with lead shielding

    1024 channel spectrum

    Touch screen display

    Printer option

    PC software option

    Peak integration and ROI reports

    Half-Life correction

    On board storage of spectra

  • Contamination, Exit and Portable Dose Rate Monitors

    Berthold provides a full range of contamination and dose rate monitors ideally suited for the PET laboratory.

    Contamination monitors can be mounted on wall brackets to provide a solution for exit monitoring or a dedicated Hand

    and Foot Monitor with personnel ID card reader option can be provided. Portable Gamma and Neutron dose rate monitors

    are available with the LB123 electronics shared between the different probes.

    LB147 Hand and Foot Monitor

    Optional card reader for user ID with PC database software logging

    Card type matched to users existing door access card

    ZnS detector with high efficiency for PET isotopes

    Touch screen display for ease of operation

    Dynamic background subtraction for operation in fluctuating backgrounds

    Detachable frisker probe

    User defined thresholds in cps or Bq/cm2

    User can economically replace damaged detector foils

    LB124SCINT Contamination Monitor

    Large area ZnS detector with high sensitivity

    Lightweight and easy to handle

    Reading in cps or Bq/cm2

    Calibration factors for all PET isotopes

    User can economically replace damaged detector foils

    Exit monitor option with wall bracket

    Larger probe (LB124Scint-300) option available, especially suited

    as an exit monitor

    LB123 Universal Monitor

    Single electronic unit which can connect to multiple

    probe types

    200cm2 contamination probe as exit monitor

    Neutron probe

    Gamma Dose rate and Integrated Dose probe

    Berthold Technologies UK Ltd, 6 Allied Business Centre, Coldharbour Lane, Harpenden, Hertfordshire

    AL5 4UT, Tel: 01582 761477, e.mail: [email protected], Web: www.Berthold.com


Recommended