Tyler Animal Hospital Electrical QTO Bid Date: 0001-01-01T00:00:00 Name Description Sq. Ft. Ft. Cu. Yd. Count Drop Count A Fixture 0.00 0.00 0.00 14 0 A1 Fixture 0.00 0.00 0.00 27 0 AP Fixture 0.00 0.00 0.00 47 0 APS Fixture 0.00 0.00 0.00 30 0 B1 Fixture 0.00 0.00 0.00 77 0 C Fixture 0.00 0.00 0.00 50 0 CS Fixture 0.00 0.00 0.00 4 0 D Fixture 0.00 0.00 0.00 18 0 EXIT Fixture 0.00 0.00 0.00 21 0 P Fixture 0.00 0.00 0.00 15 0 P1 Fixture 0.00 0.00 0.00 4 0 Pole for Fixture 0.00 0.00 0.00 7 0 EM Battery Ballast Field Installed Battery Ballast 0.00 0.00 0.00 88 0 Switch w Branch Wiring 0.00 0.00 0.00 49 0 Panel, Transformer & Feeder 0.00 0.00 0.00 8 0 Branch Light Wiring - 3#12-3/4" 0.00 3,024.14 0.00 190 0 Connection to Motor w Circuit 0.00 0.00 0.00 37 0 Power Branch Circuit 3#12-3/4" 0.00 5,792.72 0.00 212 0 Receptacle 0.00 0.00 0.00 171 0
Transcript
Page 1: Tyler Animal Hospital Electrical QTO Bid Date: 0001-01 ... · PDF fileRECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT ... Information in STACK To-Go Reports is subject to change without

Tyler Animal Hospital Electrical QTO

Bid Date: 0001-01-01T00:00:00

Name DescriptionSq.

Ft.Ft.

Cu.

Yd.Count

Drop

Count

A Fixture 0.00 0.00 0.00 14 0

A1 Fixture 0.00 0.00 0.00 27 0

AP Fixture 0.00 0.00 0.00 47 0

APS Fixture 0.00 0.00 0.00 30 0

B1 Fixture 0.00 0.00 0.00 77 0

C Fixture 0.00 0.00 0.00 50 0

CS Fixture 0.00 0.00 0.00 4 0

D Fixture 0.00 0.00 0.00 18 0

EXIT Fixture 0.00 0.00 0.00 21 0

P Fixture 0.00 0.00 0.00 15 0

P1 Fixture 0.00 0.00 0.00 4 0

Pole for Fixture 0.00 0.00 0.00 7 0

EM Battery BallastField Installed Battery

Ballast0.00 0.00 0.00 88 0

Switch w Branch Wiring 0.00 0.00 0.00 49 0

Panel, Transformer &

Feeder0.00 0.00 0.00 8 0

Branch Light Wiring -

3#12-3/4"0.00 3,024.14 0.00 190 0

Connection to Motor w

Circuit0.00 0.00 0.00 37 0

Power Branch Circuit

3#12-3/4"0.00 5,792.72 0.00 212 0

Receptacle 0.00 0.00 0.00 171 0

All information provided in the STACK To-Go Reports is provided for information purposes only. Information in STA information, To-Scale Software and it’s representatives, agents, contractors or affiliates make no guarantees of any kind.

Page 2: Tyler Animal Hospital Electrical QTO Bid Date: 0001-01 ... · PDF fileRECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT ... Information in STACK To-Go Reports is subject to change without

UP

VET. TECH

PHASE 3

124

PE

T 400

W

D

DN

LOADING

DOCK

VEST.

100H

MD/LG DOGS (18)

122

MD/SM DOGS (14)

121

CLEANING

CLOSET

121A

VEST.

100F

STAFF

RESTROOM

130

JANITOR

147 CAT QUARANTINE

(8)

146

EXIST STAIR

149

DOG HOLDING (3)

140

DOG ISO

138

RISER

133

CAT ISO

137

EUTH HLD

136

EUTH

135

PET 400

134

SURRENDER

141

DOG HOLD (4)

142

CAT HOLD (10)

143

CATS (16)

127

CATS (16)

126

ACO OFFICE

144

EXAM/TREAT/EVAL

131

DOG HLD (2)

132

VEST.

100L

VET

125

STORAGE

145

DOG Q(2)

139

FUTURE VET

PHASE 2

148

LAUNDRY

114

STAFF RR

113

STAFF RR

112

BREAK RM

111

JANITOR

110

PUBLIC RR

109

PHASE 2

108

ADOPT OFF

107

CAT DISPLAY (14)

105

DOG DISPLAY (11)

104

ADOPT LOBBY

100B

GET ACQ

103

GET ACQ

101

GET ACQ

102

VEST.

100A

CAT COLONY

106

OFFICE

119

OFFICE

118

OFFICE

117

FOOD PREP

116

STORAGE

115

VEST.

100D

SALLY PORT

129

BATH /

GROOM

128

CATS (20)

PHASE 2

123F

MED DOGS (11)

PHASE 2

123A

LG/MD DOGS (17)

PHASE 2

123C

CATS (20)

PHASE 2

123D

CATS (20)

PHASE 2

123E

CLEANING

PHASE 2

123

LG DOGS (5)

PHASE 2

123B

DW

D

W

CORR.

100C

CORRIDOR

100E

CORRIDOR

100G

DN

DN

DN

CORR.

100J

CORRIDOR

100K

MD/LG DOGS (18)

120

DN

DN

DN

UP

UP

DN

DN

+48"

D

+48"

D

+48"

D

+48"

D

+48"

GFCI

+18"

GFCI

+6" AC

GFCI

+6" AC

GFCI

+18"

GFCI

+18"

GFCI

+6" AC

GFCI

+6" AC

GFCI

+18"

GFCI

+6" AC

GFCI

+6" AC

GFCI

+6" AC

GFCI

+18"

GFCI

MDP

+48"

D

+48"

D

+48"

D

+18"

D

+18"

D

+18"

D

+18"

D

+18"

D

+18"

D

+18"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+18"

D

+18"

D

+18"

D

+48"

D

+48"

D

+48"

D

+18"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

Q

Q

Q

Q

Q

Q

+18"

GFCI

+48"

GFCI

+48"

D

+48"

D

D

D

Q

+48"

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+48"

D

+18"

GFCI

+48"

GFCI

+48"

GFCI

+48"

+48"

D

GFCI

GFCI

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

+48"

D

+48"

D

+48"

D

+48"

GFCI

Q

Q

+48"

D

+48"

D

+18"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"+48"

+48"

+48"

+6" AC

+18"

+18"

+48"

+48"

+48"

+48"

+48"+48"

+18"

D

+18"

D

J

DF

EP

D

+48"

+18"

D

+48"

D

+48"

D

J

DRY

J

DRY

DW

DW

RF

J

CREM

+48"

D

+48"

D

+18"

D

+18"

D

D

D

+48"

+48"

+48"

J

OH DOOR

+48"

+6" AC

GFCI

WMRWMR

WP

GFCI

+48"

FZR

GFCI

J

WH

SMT

GFCI

SMT

GFCI

PD-1-10

PD-1-31

PD-1-28,30

PD-2-3

PD-2-1

PD-2-2

PD-2-31,33

PD-2-5

PD-2-13

PD-2-9

PD-2-19

PD-2-14,16,18

PD-2-32,34,36

PD-2-29

PD-2-12

PD-1-22

PD-2-25,27

PD-1-17

PD-1-23

PD-1-18

PD-1-27

PD-2-26,28,30

PD-2-17

PD-1-20

PD-2-4

LP-1

PD-1

LP-2PD-2

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

PD-1-21

PD-1-36

PD-1-19

PD-1-25

PD-1-26

PD-2-38

PD-2-11

PD-1-16

Q

UC RF

SCALE

J

GFCI

HVAC-1-2,4,6

3/4"C,3#10,#10G

TWD

GFCI

TWD

GFCI

TWD

GFCI

TWD

GFCI

TWD

GFCI

PD-1-35

PD-1-43

PD-1-45

PD-1-47

PD-2-39

WP

GFCIWP

GFCI

WP

GFCI

WP

GFCI

WP

GFCI

PD-2-35

PD-2-41

+48"

+48"+48"

+48"

+48"

TWD

GFCI

PD-1-48

HOIST

PD-1-50

PD-2-6,8,10

PD-2-20,22,24

TWD

GFCI

PD-2-37

PD-2-7

PD-2-21

PD-2-23

GFCI

1. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL PULL CORDS IN ALL NEW CONDUIT

SUPPORTING THIS INSTALLATION.

2. ELECTRICAL CONTRACTOR SHALL CLEAR ALL WOOD AND DEBRIS FROM ALL DISTRIBUTION PANELS.

3. THE INSTALLATION OF ALL DISTRIBUTION PANELS AND WIRING ARE TO BE GOOD, WORKMANSHIP

QUALITY WITH 90° BENDS, LABELED WIRES, AND TYPED PANEL SCHEDULES.

4. ALL CONDUIT AND WIRE PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE CAULKED AND SEALED

IN ACCORDANCE TO THE N.E.C. AND ALL BUILDING CODE REQUIREMENTS.

5. ALL INTERIOR BRANCH CIRCUIT WIRING SHALL BE IN EMT OR PVC CONDUIT, OR MC CABLE UNLESS

OTHERWISE INDICATED ON THESE DRAWINGS. ALL EXTERIOR WIRING SHALL BE IN RIGID METAL CONDUIT.

6. ALL MECHANICAL HVAC EQUIPMENT SHALL HAVE HACR BREAKERS PROVIDED AND INSTALLED BY THE

ELECTRICAL CONTRACTOR IN THEIR SUPPORTING ELECTRICAL PANELS.

REQUIRED OUTLET HEIGHTS ARE LISTED ON THIS DRAWING.

HEIGHTS LISTED WITH THE SUFFIX 'AC' ARE MEASURED

FROM THE COUNTER (I.E. +6" AC INDICATES AN OUTLET

THAT IS INSTALLED 6" ABOVE THE COUNTER. HEIGHTS

LISTED WITHOUT A SUFFIX ARE MEASURED FROM THE

FINISHED FLOOR.

RECEPTACLE HEIGHT

ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND

CONFIRMING FINAL LOCATIONS OF ALL OUTLETS AND SWITCHES WITH THE

OWNER PRIOR TO COMPLETING INSTALLATION. CONTRACTOR SHALL

RECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT THE LOCATIONS

ARE ACCEPTABLE. ANY REQUIRED REWORK, RESULTING FROM A FAILURE

TO RECEIVE THIS CONFIRMATION, WILL BE PERFORMED AT THE

CONTRACTOR'S OWN EXPENSE.

OUTLET LOCATIONS

ALL CONDUIT SHALL HAVE LONG RADIUS SWEEPS OR SWEPT 45°. ALL CONDUIT TERMINATIONS ARE TO HAVE

BUSHING UNLESS THEY ARE INTO A JUNCTION BOX WITH A SOLID MECHANICAL CONNECTION. MAKE SURE ALL

CONDUITS ARE FREE OF BURRS OR OTHER DEBRIS THAT COULD DAMAGE WIRE. LOCATE ALL BURIED CONDUITS

AT A DEPTH OF 24 INCHES BELOW GRADE.

IF A CONDUIT REQUIRES MORE THAN TWO 90-DEGREE BENDS, PROVIDE A PULL BOX BETWEEN SECTIONS WITH

TWO BENDS OR LESS.

IF A CONDUIT REQUIRES A REVERSE BEND (BETWEEN 100 DEGREES AND 180 DEGREES), INSERT A PULL POINT OR

PULL BOX AT EACH BEND HAVING AN ANGLE FROM 100 DEGREES TO 180 DEGREES.

IF A CONDUIT REQUIRES A THIRD 90 DEGREE BEND BETWEEN PULL POINTS OR PULL BOXES, DO ONE OF THE

FOLLOWING:

- ENSURE THE TOTAL CONDUIT RUN IS NOT LONGER THAN 10M (33 FT.)

OR - INCREASE THE CONDUIT SIZE TO THE NEXT TRADE SIZE (LARGER)

THERE SHOULD BE NO CONTINUOUS CONDUIT RUNS OF GREATER THAN 100 FT (WITHOUT A PULL BOX). METALLIC

CONDUITS SHOULD BE BONDED TO GROUND AT BOTH ENDS.

REGARDING THE ISSUE OF ELECTRICAL AND DATA CABLES CROSSING EACH OTHER IN CONDUITS. FOLLOW THE

RULES LISTED BELOW WHEN CROSSING OR RUNNING ALONGSIDE A CONDUIT. THE CONDUITS SHOULD ALL HAVE

SHIELDING PROPERTIES THAT ARE BEING RUN UNDERGROUND WITHIN PROXIMITY OF EACH OTHER.

MINIMUM SEPARATION DISTANCES:

- UNSHIELDED POWER LINES OR EQUIPMENT IN PROXIMITY TO OPEN OR NON-METALLIC PATHWAYS - 24 IN.

- UNSHIELDED POWER LINES OR EQUIPMENT IN PROXIMITY TO GROUNDED METALLIC PATHWAYS - 12 IN.

- POWER LINES ENCLOSED IN A GROUNDED METALLIC CONDUIT (OR OTHERWISE SHIELDED) - 6 IN.

- ELECTRICAL MOTORS AND TRANSFORMERS - 47 IN.

CONDUIT NOTES

POWER DISTRIBUTION NOTES

NORTH

4055 International P

laza, S

uite 200

Fort W

orth, T

exas 76109-4895

Phone - (817) 735-7300

Fax - (817) 735-7491

SHEET

DA

TE

DE

SIG

NE

D

DR

AW

N

RE

VIS

ED

CH

EC

KE

D

VE

RIF

Y S

CA

LE

01

Bar is one inch on origianl draw

ing. If

not one inch on this sheet, adjust scale.

116 M

ain S

treet

Norw

ich, C

onnecticut 06360

T: 860.889.7078

Co

pyrig

ht 2

01

5 D

esig

n L

ea

rn

ed

ISSUED FOR CONSTRUCTION

04

/3

0/2

01

5

CIT

Y O

F T

YLE

R

TY

LE

R A

NIM

AL C

AR

E F

AC

ILIT

Y

42

18

C

HA

ND

LE

R H

IG

HW

AY

FIR

ST

F

LO

OR

P

OW

ER

A

ND

PA

NE

L L

AY

OU

T

E2.01

AJK

AJK

CS

L

-

EL

EC

TR

IC

AL

TRENCH WASHDOWN RECEPTACLE LOCATIONS SHALL BE COORDINATED

WITH THE TRENCH WASHDOWN RECESSED BOX TO PROVIDE POWER TO

THE TIME RELEASE SOLENOID VALVE LOCATED WITHIN.

TRENCH WASHDOWN RECEPTACLES

THE HOIST SHALL BE A DAYTON 4GU72 ELECTRIC WIRE ROPE HOIST. THE

HOIST SHALL HAVE A MINIMUM OF 10 FEET OF LIFT AND A LOAD

CAPACITY OF 500LB. THE CONTRACTOR SHALL SUPPLY A FESTOON

SYSTEM KIT TO RUN PARALLEL TO MONORAIL SYSTEM. A DAYTON 33N207

SHALL BE USED. THE CONTRACTOR SHALL SUPPLY ENOUGH CORD TO

RUN THE ENTIRE LENGTH OF THE SYSTEM WITHOUT RESTRICTION.

PET400 HOIST

6'

All information provided in the STACK To-Go Reports is provided for information purposes only. Information in STACK To-Go Reports is subject to change without prior notice. Although every reasonable effort is made to present current and accurate information, To-Scale Software and it’s representatives, agents, contractors or affiliates make no guarantees of any kind.

Page 3: Tyler Animal Hospital Electrical QTO Bid Date: 0001-01 ... · PDF fileRECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT ... Information in STACK To-Go Reports is subject to change without

RTU-1

MEZZANINE

UP

EXIST STAIR

149

0' 8' 16' 24'

WE

S

W.H. W.H.

RTU 4

RTU-4

RTU-5

RTU-6

RTU-7

RTU-12

ACC-13

AHU-13

ACC-14

AHU-14

ACC-15

AHU-15

ACC-16

AHU-16

CIRC PUMP

J

WH

J

WH

HVAC-2HVAC-1

T

XFMR-1

HVAC-2-14,16,18

HVAC-2-7,9,11

PD-1-6,8

PD-1-7,9

PD-1-14

PD-1-12

PD-1-24

HVAC-1-1,3,5

1"C,3#10,#10N,#10G

HVAC-1-8,10,12

1-1/4"C,3#8,#8N,#10G

HVAC-1-14,16,18

HVAC-1-19,21,23

HVAC-2-2,4,6

HVAC-2-1,3,5

1-1/4"C,3#8,#8N,#10G

HVAC-2-8,10,12

MAINT

GFCI

MAINT

GFCI

MAINT

GFCI

MAINT

GFCI

MAINT

GFCI

MAINT

GFCI

MAINT

GFCI

D

D

D

D

D

APSAPS EMAPS

APS EMAPS

APS EM APS

PD-1-32

#10

WP

WP

WP

WP

WP

WP

WP

MAINT

WP

GFCI

PD-1-33

#10

PD-1-34

#10

HVAC-1-13,15,17

AHU-2

ERV-1

PD-1-44,46

#10

ERV-2

ERV-4

ERV-5,6,7

ERV-13

ERV-14

ERV-15

ERV-16

HVAC-2-20,22,24

HVAC-2-26,28,30

HVAC-2-32,34,36

HVAC-2-38,40,42

HVAC-2-31,33,35

ACC-2

HVAC-2-19,21,23

PD-1-1,3,5

#10

HVAC-2-25,27,29

PD-1-2,4

#10

HVAC-2-43,45,47

HVAC-2-37,39,41

LP-1-11

#10

EXIT

NORTH

4055 International P

laza, S

uite 200

Fort W

orth, T

exas 76109-4895

Phone - (817) 735-7300

Fax - (817) 735-7491

SHEET

DA

TE

DE

SIG

NE

D

DR

AW

N

RE

VIS

ED

CH

EC

KE

D

VE

RIF

Y S

CA

LE

01

Bar is one inch on origianl draw

ing. If

not one inch on this sheet, adjust scale.

116 M

ain S

treet

Norw

ich, C

onnecticut 06360

T: 860.889.7078

Co

pyrig

ht 2

01

5 D

esig

n L

ea

rn

ed

ISSUED FOR CONSTRUCTION

04

/3

0/2

01

5

CIT

Y O

F T

YLE

R

TY

LE

R A

NIM

AL C

AR

E F

AC

ILIT

Y

42

18

C

HA

ND

LE

R H

IG

HW

AY

RO

OF

A

ND

M

EZ

ZA

NIN

E P

OW

ER

AN

D P

AN

EL

L

AY

OU

T

E2.02

AJK

AJK

CS

L

-

EL

EC

TR

IC

AL

1. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL PULL CORDS IN ALL NEW CONDUIT

SUPPORTING THIS INSTALLATION.

2. ELECTRICAL CONTRACTOR SHALL CLEAR ALL WOOD AND DEBRIS FROM ALL DISTRIBUTION PANELS.

3. THE INSTALLATION OF ALL DISTRIBUTION PANELS AND WIRING ARE TO BE GOOD, WORKMANSHIP

QUALITY WITH 90° BENDS, LABELED WIRES, AND TYPED PANEL SCHEDULES.

4. ALL CONDUIT AND WIRE PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE CAULKED AND SEALED

IN ACCORDANCE TO THE N.E.C. AND ALL BUILDING CODE REQUIREMENTS.

5. ALL INTERIOR BRANCH CIRCUIT WIRING SHALL BE IN EMT OR PVC CONDUIT, OR MC CABLE UNLESS

OTHERWISE INDICATED ON THESE DRAWINGS. ALL EXTERIOR WIRING SHALL BE IN RIGID METAL CONDUIT.

6. ALL MECHANICAL HVAC EQUIPMENT SHALL HAVE HACR BREAKERS PROVIDED AND INSTALLED BY THE

ELECTRICAL CONTRACTOR IN THEIR SUPPORTING ELECTRICAL PANELS.

REQUIRED OUTLET HEIGHTS ARE LISTED ON THIS DRAWING.

HEIGHTS LISTED WITH THE SUFFIX 'AC' ARE MEASURED

FROM THE COUNTER (I.E. +6" AC INDICATES AN OUTLET

THAT IS INSTALLED 6" ABOVE THE COUNTER. HEIGHTS

LISTED WITHOUT A SUFFIX ARE MEASURED FROM THE

FINISHED FLOOR.

RECEPTACLE HEIGHT

ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND

CONFIRMING FINAL LOCATIONS OF ALL OUTLETS AND SWITCHES WITH THE

OWNER PRIOR TO COMPLETING INSTALLATION. CONTRACTOR SHALL

RECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT THE LOCATIONS

ARE ACCEPTABLE. ANY REQUIRED REWORK, RESULTING FROM A FAILURE

TO RECEIVE THIS CONFIRMATION, WILL BE PERFORMED AT THE

CONTRACTOR'S OWN EXPENSE.

OUTLET LOCATIONS

ALL CONDUIT SHALL HAVE LONG RADIUS SWEEPS OR SWEPT 45°. ALL CONDUIT TERMINATIONS ARE TO HAVE

BUSHING UNLESS THEY ARE INTO A JUNCTION BOX WITH A SOLID MECHANICAL CONNECTION. MAKE SURE ALL

CONDUITS ARE FREE OF BURRS OR OTHER DEBRIS THAT COULD DAMAGE WIRE. LOCATE ALL BURIED CONDUITS

AT A DEPTH OF 24 INCHES BELOW GRADE.

IF A CONDUIT REQUIRES MORE THAN TWO 90-DEGREE BENDS, PROVIDE A PULL BOX BETWEEN SECTIONS WITH

TWO BENDS OR LESS.

IF A CONDUIT REQUIRES A REVERSE BEND (BETWEEN 100 DEGREES AND 180 DEGREES), INSERT A PULL POINT OR

PULL BOX AT EACH BEND HAVING AN ANGLE FROM 100 DEGREES TO 180 DEGREES.

IF A CONDUIT REQUIRES A THIRD 90 DEGREE BEND BETWEEN PULL POINTS OR PULL BOXES, DO ONE OF THE

FOLLOWING:

- ENSURE THE TOTAL CONDUIT RUN IS NOT LONGER THAN 10M (33 FT.)

OR - INCREASE THE CONDUIT SIZE TO THE NEXT TRADE SIZE (LARGER)

THERE SHOULD BE NO CONTINUOUS CONDUIT RUNS OF GREATER THAN 100 FT (WITHOUT A PULL BOX). METALLIC

CONDUITS SHOULD BE BONDED TO GROUND AT BOTH ENDS.

REGARDING THE ISSUE OF ELECTRICAL AND DATA CABLES CROSSING EACH OTHER IN CONDUITS. FOLLOW THE

RULES LISTED BELOW WHEN CROSSING OR RUNNING ALONGSIDE A CONDUIT. THE CONDUITS SHOULD ALL HAVE

SHIELDING PROPERTIES THAT ARE BEING RUN UNDERGROUND WITHIN PROXIMITY OF EACH OTHER.

MINIMUM SEPARATION DISTANCES:

- UNSHIELDED POWER LINES OR EQUIPMENT IN PROXIMITY TO OPEN OR NON-METALLIC PATHWAYS - 24 IN.

- UNSHIELDED POWER LINES OR EQUIPMENT IN PROXIMITY TO GROUNDED METALLIC PATHWAYS - 12 IN.

- POWER LINES ENCLOSED IN A GROUNDED METALLIC CONDUIT (OR OTHERWISE SHIELDED) - 6 IN.

- ELECTRICAL MOTORS AND TRANSFORMERS - 47 IN.

CONDUIT NOTES

POWER DISTRIBUTION NOTES

All information provided in the STACK To-Go Reports is provided for information purposes only. Information in STACK To-Go Reports is subject to change without prior notice. Although every reasonable effort is made to present current and accurate information, To-Scale Software and it’s representatives, agents, contractors or affiliates make no guarantees of any kind.

Page 4: Tyler Animal Hospital Electrical QTO Bid Date: 0001-01 ... · PDF fileRECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT ... Information in STACK To-Go Reports is subject to change without

UP

VET. TECH

PHASE 3

124

PE

T 400

W

D

DN

LOADING

DOCK

VEST.

100H

MD/LG DOGS (18)

122

MD/SM DOGS (14)

121

CLEANING

CLOSET

121A

VEST.

100F

STAFF

RESTROOM

130

JANITOR

147 CAT QUARANTINE

(8)

146

EXIST STAIR

149

DOG HOLDING (3)

140

DOG ISO

138

RISER

133

CAT ISO

137

EUTH HLD

136

EUTH

135

PET 400

134

SURRENDER

141

DOG HOLD (4)

142

CAT HOLD (10)

143

CATS (16)

127

CATS (16)

126

ACO OFFICE

144

EXAM/TREAT/EVAL

131

DOG HLD (2)

132

VEST.

100L

VET

125

STORAGE

145

DOG Q(2)

139

FUTURE VET

PHASE 2

148

LAUNDRY

114

STAFF RR

113

STAFF RR

112

BREAK RM

111

JANITOR

110

PUBLIC RR

109

PHASE 2

108

ADOPT OFF

107

CAT DISPLAY (14)

105

DOG DISPLAY (11)

104

ADOPT LOBBY

100B

GET ACQ

103

GET ACQ

101

GET ACQ

102

VEST.

100A

CAT COLONY

106

OFFICE

119

OFFICE

118

OFFICE

117

FOOD PREP

116

STORAGE

115

VEST.

100D

SALLY PORT

129

BATH /

GROOM

128

CATS (20)

PHASE 2

123F

MED DOGS (11)

PHASE 2

123A

LG/MD DOGS (17)

PHASE 2

123C

CATS (20)

PHASE 2

123D

CATS (20)

PHASE 2

123E

CLEANING

PHASE 2

123

LG DOGS (5)

PHASE 2

123B

DW

D

W

CORR.

100C

CORRIDOR

100E

CORRIDOR

100G

DN

DN

DN

CORR.

100J

CORRIDOR

100K

MD/LG DOGS (18)

120

DN

DN

DN

UP

UP

DN

DN

3

3

3

3

3

3

3

3

3

3

AP EMAPAPAPAP EMAP EM

AP

AP

A1 EM A1

AP

AP EMA1 EM A1

A1

A1 EM

A1

A1 EM

AP

AP EMAP EM

AP

AP EMAP

AP

A

A

A EM

A1

A1

A1

A1 EM

A1A1

A1A1 EM

A1 EM

A1A1

A1

A

AP EM AP AP AP AP EM AP AP AP

AP EM

AP

AP

AP EM

AP

APS EM

APS

APS

APS EM

APAPAPAPAPAPAPAP EM

APS EM

APS EM

APS EM

APSAPS EMAPS

APS

AP EM

APS EM

APS

APS EM

APSAPS EM

APS EM APS

AP EM AP

C

B1 B1 B1

B1 EM B1 B1 B1 B1

D D D

B1B1B1

D

D

D

D

D

A A EM

A

A EM A

C

C EMC

C

A1

AP EM AP EM

AP

APC EM

A EM

A

C EM C

C C

C EM

C

C

C

C

CC EMCCCC EMC

C EM

C EM

C EM C

CSCS EM

CS CSA

C

C

B1

B1

DD

B1 B1 EM

C C EM C EM C

C EM

C

C EM

C

A

A1

A1 EM

C EM C C EM C C EM CC

C EM

AP EM

LP-1-1

LP-1-3

LP-1-5

LP-1-9

LP-2-3

LP-2-2

LP-2-1

LP-2-6

LP-2-4

LP-1-7

LP-2-5

3

3

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1 EM

B1

B1 EM

B1

B1

B1 EM

B1

B1 EM

B1

B1

B1 EM

B1 EM

B1

B1 EM

B1

B1 EM

B1

B1

B1

B1 EM

B1 B1 B1

B1 EMB1 EM

OS

B1

B1

B1

B1

B1B1

B1B1

B1

B1

B1 EM

B1

B1

B1

B1

B1

B1

B1

LP-2-8

LP-2-10

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

D EXT

D EXT

D EXT D EXT

D EXT

D EXT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

D EXT D EXT

LP-1-10

ALL INTERIOR LIGHTING IS DESIGNED TO SUIT THE INDIVIDUAL ENVIRONMENTS. IN

AREAS WHERE THE ENVIRONMENT IS WET, DAMP, OR HUMID THE LIGHTING

FIXTURES WILL BE GASKETED AND SEALED IN OTHER AREAS GASKETED LIGHTING

IS USED TO PREVENT HAIR ACCUMULATION OR AVOID BACTERIAL

CONTAMINATION. ALL INTERIOR LIGHT WIRING SHALL BE ROUTED IN EMT OR MC

CABLE. ALL BALLASTS ARE TO BE ENERGY EFFICIENT ELECTRONIC BALLASTS.

EXTERIOR LIGHTING SHALL BE INSTALLED WITH NEMA 4R FITTINGS .

CONTRACTOR TO INCLUDE COST AND INSTALLATION OF NEW HOMERUNS BACK TO

THE NEW PANELBOARD. CONTRACTOR ALSO TO INCLUDE THE COST AND

INSTALLATION OF ASTRONOMICAL TIME CLOCKS TO CONTROL SITE AND FACADE

LIGHTING..

LIGHTING SCOPE OF WORK

1. ELECTRICAL CONTRACTOR SHALL WIRE EXIT LIGHTING TO LOCAL AREA LIGHTING CIRCUITS,

AHEAD OF SWITCHES, PER N.E.C. 700-12(E).

2. ALL WIRING SHALL BE IN EMT CONDUIT OR MC CABLE WITHOUT EXCEPTION.

3. PROVIDE AND INSTALL PULL CORDS IN ALL CONDUIT.

4. ALL SWITCHES AND RECEPTACLES SCHEDULED AND SHOWN IN THE ANIMAL AREAS SHALL BE

IN NEMA 3R ENCLOSURES WITH GASKETED COVERS, AND MOUNTED AT 48 INCHES ABOVE

FLOOR UNLESS OTHERWISE INDICATED.

5. THE CONTRACTOR SHALL PROVIDE EACH INTERIOR AREA REQUIRING A MANUAL CONTROL

SWITCH TO HAVE THE ABILITY TO REDUCE THE LIGHTING BY 50 PERCENT EXCEPT CORRIDORS,

STOREROOMS, REST ROOMS, LOBBIES OR ROOMS WITH ONE LUMINAIRE. AREAS SPECIFIED

WITH OCCUPANCY SENSORS ARE EXEMPT.

6. CONTRACTOR SHALL INCLUDE THE COST OF ALL HOME RUN CIRCUITS TO BREAKERS AS

INDICATED ON PANEL SCHEDULES.

7. THE BUILDING REQUIRES AN AUTOMATIC CONTROL IF NOT IN USE 24/7.

ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND

CONFIRMING FINAL LOCATIONS OF ALL OUTLETS AND SWITCHES WITH THE

OWNER PRIOR TO COMPLETING INSTALLATION. CONTRACTOR SHALL

RECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT THE LOCATIONS

ARE ACCEPTABLE. ANY REQUIRED REWORK, RESULTING FROM A FAILURE

TO RECEIVE THIS CONFIRMATION, WILL BE PERFORMED AT THE

CONTRACTOR'S OWN EXPENSE.

OUTLET AND SWITCH LOCATIONS

LIGHTING NOTES

EXIT LIGHTS

EXIT LIGHTING CIRCUITING NOT SHOWN FOR CLARITY. REFER TO

LIGHTING NOTE #1.

EMERGENCY LIGHTING

FIXTURES WITH A SUFFIX OF 'EM' HAVE BEEN SPECIFIED WITH

BATTERY PACKS TO PROVIDE EMERGENCY LIGHTING IN THE EVENT

OF A POWER FAILURE. AN UNSWITCHED SOURCE OF POWER IS

REQUIRED TO BE RUN TO THE EMERGENCY BALLASTS. THE

EMERGENCY BALLAST MUST BE FED FROM THE SAME BRANCH

CIRCUIT AS THE AC BALLAST. REFER TO TYPICAL WIRING DETAIL ON

THIS SHEET AND MANUFACTURER'S INSTALLATION INSTRUCTIONS

FOR WIRING REQUIREMENTS.

EMERGENCY LIGHTING WIRING DETAIL

WALL

SWITCH

HOT

TEST

SWITCH

EMERGENCY

BALLAST

AC

BALLAST

BLK

RED

BLK

RED

COM

WHT/RED

ORANGE

WHT

WHT/BLK

BLK

WHT

NORTH

4055 International P

laza, S

uite 200

Fort W

orth, T

exas 76109-4895

Phone - (817) 735-7300

Fax - (817) 735-7491

SHEET

DA

TE

DE

SIG

NE

D

DR

AW

N

RE

VIS

ED

CH

EC

KE

D

VE

RIF

Y S

CA

LE

01

Bar is one inch on origianl draw

ing. If

not one inch on this sheet, adjust scale.

116 M

ain S

treet

Norw

ich, C

onnecticut 06360

T: 860.889.7078

Co

pyrig

ht 2

01

5 D

esig

n L

ea

rn

ed

ISSUED FOR CONSTRUCTION

04

/3

0/2

01

5

CIT

Y O

F T

YLE

R

TY

LE

R A

NIM

AL C

AR

E F

AC

ILIT

Y

42

18

C

HA

ND

LE

R H

IG

HW

AY

LIG

HT

IN

G L

AY

OU

T

E3.01

AJK

AJK

CS

L

-

EL

EC

TR

IC

AL

PHASED AREAS

DUE TO SAFETY CONCERNS, LIGHTING IN PHASE 2 AND PHASE 3 SHALL

REMAIN. LIGHTING CIRCUITS SHALL RUN TO LOCAL LIGHTING PANEL.

All information provided in the STACK To-Go Reports is provided for information purposes only. Information in STACK To-Go Reports is subject to change without prior notice. Although every reasonable effort is made to present current and accurate information, To-Scale Software and it’s representatives, agents, contractors or affiliates make no guarantees of any kind.

Page 5: Tyler Animal Hospital Electrical QTO Bid Date: 0001-01 ... · PDF fileRECEIVE WRITTEN NOTIFICATION FROM THE OWNER THAT ... Information in STACK To-Go Reports is subject to change without

POLE

POLE

POLE

POLE

P

P

P

P

P

P

P

P

P

P-L

P-L

P-L

P-L

P-L

P

POLE

LP-1-2

LP-1-2

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-6

LP-1-4

LP-1-4

LP-1-4

J

SIGN

J

GATE

PD-1-49

PD-1-29

EXTERIOR LIGHTING SHALL BE INSTALLED WITH NEMA 4R FITTINGS .

CONTRACTOR TO INCLUDE COST AND INSTALLATION OF NEW HOMERUNS BACK TO

NEW PANELBOARD. CONTRACTOR ALSO TO INCLUDE THE COST AND

INSTALLATION OF AN ASTRONOMICAL TIME CLOCK OR PHOTOSENSORS FOR

EXTERIOR LIGHTING CONTROL.

REFER TO DETAIL SHEET FOR GENERAL UNDERGROUND CONDUIT TRENCHING.

COORDINATE ALL TRENCH WORK WITH OTHER UTILITIES, CIVIL PLANS AND SITE

CONTRACTOR.

SITE LIGHTING SCOPE OF WORK

UTILITY TRANSFORMER

LOCATION OF MAIN TRANSFORMER AND METERING

EQUIPMENT TO BE COORDINATED ON SITE WITH

LOCAL UTILITY REPRESENTATIVE

EXTERIOR LIGHTS WILL BE CONTROLLED BY TWO ASTRONOMICAL TIME CLOCKS

(INTERMATIC MODEL #ET8415CR) LOCATED WITH THE ELECTRICAL/ TELCOM

EQUIPMENT. ONE SWITCH WILL CONTROL ALL FACADE AND SIGN LIGHTING, THE OTHER

SWITCH WILL CONTROL ALL POLE MOUNTED AREA LIGHTING.

TIME CLOCK REQUIREMENTS

1. ALL BURIED WIRING SHALL BE IN SCHEDULE 40 PVC WITHOUT EXCEPTION.

2. PROVIDE AND INSTALL PULL CORDS IN ALL CONDUIT.

3. THE CONTRACTOR SHALL PROVIDE EXTERIOR LIGHTING WITH AUTOMATIC

SWITCHING OR PHOTOCELL CONTROLS FOR ALL EXTERIOR LIGHTING NOT INTENDED

FOR 24-HOUR OPERATION. AUTOMATIC TIME SWITCHES SHALL HAVE A COMBINATION

SEVEN DAY AND SEASONAL DAYLIGHT SCHEDULE ADJUSTMENT AND A MINIMUM FOUR

HOUR POWER BACKUP.

SITE LIGHTING NOTES

NORTH

4055 International P

laza, S

uite 200

Fort W

orth, T

exas 76109-4895

Phone - (817) 735-7300

Fax - (817) 735-7491

SHEET

DA

TE

DE

SIG

NE

D

DR

AW

N

RE

VIS

ED

CH

EC

KE

D

VE

RIF

Y S

CA

LE

01

Bar is one inch on origianl draw

ing. If

not one inch on this sheet, adjust scale.

116 M

ain S

treet

Norw

ich, C

onnecticut 06360

T: 860.889.7078

Co

pyrig

ht 2

01

5 D

esig

n L

ea

rn

ed

ISSUED FOR CONSTRUCTION

04

/3

0/2

01

5

CIT

Y O

F T

YLE

R

TY

LE

R A

NIM

AL C

AR

E F

AC

ILIT

Y

42

18

C

HA

ND

LE

R H

IG

HW

AY

SIT

E L

IG

HT

IN

G

E3.04

AJK

AJK

CS

L

-

EL

EC

TR

IC

AL

All information provided in the STACK To-Go Reports is provided for information purposes only. Information in STACK To-Go Reports is subject to change without prior notice. Although every reasonable effort is made to present current and accurate information, To-Scale Software and it’s representatives, agents, contractors or affiliates make no guarantees of any kind.