Proposed study in the AtR Line
• Type: Parasitic• Why: To investigate non-linearities in the
AtR combined function magnets.
N. Tsoupas, A. Jain, W. Glenn, W. W. MacKay, W. Meng, others…
2
Schematic arrangement of the U_line and W_line Flags that are used to measure the beam profiles
4.250 bend
uxf1
Uf2 1 mm Al2O3
uxf3
80 bend
200 bend
W foil 0.025 mm
Uf3
Uf4
Uf5
Wf1
Wf2
Wf3
Uf3,Uf4, Uf5 (2 mil Cd2O2S:Tb on 1 mil Al sub tray)
Wf1,Wf2, Wf3 (2 mil Cd2O2S:Tb on 1 mil Al sub tray)
3
Why this Study?
• In an effort to explain the above observations we propose measurements to study the effects of non-linearities in the combined function magnets of AtR
Experimentally calc. Beam Parameters at Start of AtR
Theoretically calc. Beam Parameters at Start of AtR
Not always in agreement
Experimentally calc. Beam Parameters at Start of AtR
Using U_line Flags
Experimentally calc. Beam Parameters at Start of AtR
Using W_line Flags
4
In the rest of the presentation:
a) We show evidence of the allegations madeabove.
b) we provide proof that non-linearities in thecombined function magnets of the AtR canactually cause these effects.
and:c) MOST IMPORTANT:
Non-linearities in the magnets cause a miss-match of the injected beam in RHIC with thecirculating beam
5
How we measure the beam parameters at the Start of the AtR? (next two slides)
6
7
Formalism to calculate the beam emittance and the beam parameters at the beginning of the AtR line
(σ11)out = (R11)2(σ11)in + 2(R11) (R12)(σ12)in + (R12)2(σ22)in+ 2(R11) (R16)(σ16)in + 2(R12) (R16)(σ26)in + (R16)2(σ66)in
(σ33)out = (R33)2(σ33)in + 2(R33) (R34)(σ34)in + (R34)2(σ44)in + 2(R33) (R36)(σ36)in + 2(R34) (R36)(σ46)in + (R36)2(σ66)in
(σ11)out = (R11)2(σ11)in + 2(R11) (R12)(σ12)in + (R12)2(σ22)in(σ33)out = (R33)2(σ33)in + 2(R33) (R34)(σ34)in + (R34)2(σ44)in
If the Location and the strength of the magnets in the AtR Line are known the calculated beam parameters and beam emittance depend on the measured “sigma’s” of the beam at the location of the flags.
εx = [ (σ11)in(σ22)in - (σ12)in2 ]1/2
(βx) in= [(σ11)in] /[ (σ11)in(σ22)in - (σ12)in2 ]1/2=(σ11) in/εx
(αx)in= -[(σ12)in] /[ (σ11)in(σ22)in - (σ12)in2 ]1/2=-(σ12) in/εx
8
More details on What Prompted this Study
• Short term measurements yield same results on the calculated beam parameters from measured beam widths.
• Long term measurements may yield different results.
• The measured beam size depends on the location of the beam image on the flag. This affects the calculated emittance and beam parameters.
9
Short term measurements (~30 minutes time span)
10
What Prompted this Study?
• Long term measurements may yield different results in the measurements of beam emittance and beam parameters.
11
Long term measurements (~Few months time span) pp06
Date εx π[mm.mrad]
βx
[m]αx εx
π[mm.mrad]βx
[m]αx
Feb. 07 06 15.8 24.1 -3.1 26.8 13.3 1.9Mar. 17 06 15.9 42.8 -5.1 26.5 9.9 1.3
12
DHT2[mrad]
εx π[mm.mrad]
βx
[m]αx εx
π[mm.mrad]βx
[m]αx
0.000 7.0 18.4 -2.3 11.0 5.5 1.05
0.025 8.0 16.9 -1.8 13.3 5.5 0.63
0.075 7.7 14.9 -1.85 13.0 6.7 1.26
0.125 6.2 24.8 -3.07 8.7 3.9 0.65
0.175 7.2 15.0 -1.71 12.3 5.7 0.90
The measured beam emittance and beam parameters depend on the location of the beam image on the flags.
W_flags Run-pp06
13
Possible explainations on what may affect the measured beam emittance and beam parameters.
• The beam trajectory in the AtR line, under the assumption that the magnets are not “linear”. Mainly the Combined Function dipole magnets.
• Random errors in the magnetic field settings of the AtR magnets
• Misalignment of the AtR Magnets.
14
Effect of “K2 component” of the 8o bend on the beam parameters at the Start of the AtR
(next six slides)
15
Location of the Combined Function Magnets and of the AtR Flags
16
Bends of the AtR line
Bend Name Angle[o] No of Mag.
Dipole type Type Gap
[mm]K0
[rad]K1
[m-2]K2
[m-3]
Four deg. 4.25o 2 Uniform A 38.5 0.0376 0.0000 0.00
Eight deg. 8o 4 Cf C 39 0.0349 0.01882 ??
Twenty deg. 20o 8 Cf C 39 0.04363 0.02352 ??
Ninety deg. 86.25o
1 Uniform Switch 0.04769 0.0000 0.00
29 Cf C 32 0.04815 0.03809 ??
1 Uniform A 29 0.04280 0.0000 0.00
17
Beta and dispersion functions the AtR Line
18
Assume a value of K2=0.015 [m-3]in the combined function magnets
19
Xdisp with corrector UTH2 = +0.75 mrad
20
βx,y, ηx,y, and σx as function of UTH2 strength
Flag UTH2 βx ηx σx βy ηy σy[mrad] [m] [m] [mm] [m] [m] [mm]
Uf3 -0.75 16.573 0.048 1.314 77.275 0.000 2.837UF3 0.00 13.048 0.000 1.166 56.593 0.000 2.428Uf3 0.75 9.883 -0.040 1.015 41.573 0.000 2.081
Uf4 -0.75 36.418 0.160 1.951 13.445 0.000 1.183Uf4 0.00 50.445 0.000 2.292 12.307 0.000 1.132Uf4 0.75 70.500 -0.211 2.714 13.622 0.000 1.191
Uf5 -0.75 12.024 0.016 1.119 38.408 0.000 2.000Uf5 0.00 12.664 0.000 1.149 51.375 0.000 2.313Uf5 0.75 16.145 -0.045 1.297 70.419 0.000 2.708
21
Calculated beam emitances and beam parameters at AtR_Start for two different beam trajectories
UTH2[mrad]
εx π[mm.mrad] βx [m] αx βy [m] αy Flags
0.00 15.00 31.39 -3.04 7.92 0.99 U_line
0.75 15.01 24.43 -2.57 10.54 1.47 U_line
0.00 15.00 31.55 -3.06 7.96 0.99 W_line
0.75 16.90 29.95 -2.95 11.04 1.52 W_line
22
Effect of non-linearities of the 8o bend on the beam parameters at the Start of the AtR
(next two slides)
23
Model one of the 8o combined function magnet (Whuzeng Meng) opera code.
The R_matrices of the 8o AtR bend are calculated for three possible AtR trajectories.
24
βx, at UF4 location as function of UTH2 strength
Flag UTH2 βx βy Comments[mrad] [m] [m]
Uf4 1.00 55.86 11.1 3DcalcUf4 0.00 50.64 10.7 3DcalcUf4 -100 27.34 10.1 3Dcalc
25
Effects of Random Magnet errors and Magnets misalignments on the measured
beam emittance and beam parameters
26
Εxπ[mm.mrad] βx [m] αx
Εxπ[mm.mrad] βx [m] αx
15.0±0.15 31.4±0.3 -3.04±0.03 15.0±0.2 7.9±0.1 0.99±0.02
Calculated emittances and beam parameters at the beginning of the AtR line with the calculated errors. The errors were caused by assuming a ±0.5% random error in the settings of the AtR magnets.
27
Last but NOT least the effect of the non-ideal beam trajectory at the beam parameters and
dispersion at the RHIC injection point
UTH2[mrad] βx [m] ηx [m] σx βy [m] αy Loc.
-0.75 36.8 -3.5 3.2 21.2 -0.02 XEND
0.00 33.3 1.4 2.1 18.6 0.02 XEND
0.75 28.4 6.1 4.6 15.7 0.06 XEND
28
Conclusions
• There is evidence of non-linearities in the combined function magnets of the AtR line– It affects the measured values of the beam parameters.
• Random magnets errors of ±0.5% in the settings of the AtR magnets does not affect significantly the measured values of the beam emittances and beam parameters.
• Same is true (no big effect) for magnet misalignments: – {Δx, Δy, ΔS} = ±0.75 [mm] – {Δθ, Δφ, Δψ} = ±0.75 [mrad]