3/4"
SUSPENSION (BY
OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIPS
* ACOUSTICAL BACKER RECOMMENDED
T&G GRID CLIP FOR
15
16
" HD T-GRID ONLY
6" = 1'-0"
1
TYPICAL AUDITION PLANK SECTION DETAIL
1' = 1'-0"
2
T&G GRID CLIP
1' = 1'-0"
3
T&G DIRECT ATTACH CLIP
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - SECTION & CLIP OPTIONS
SHEET NUMBER
1
TONGUE SIDE
GROOVE SIDE
PERFORATIONS (DO
NOT GO THROUGH TO
FRONT SIDE OF PANEL)
PLANK FACE
TONGUE SIDE
GROOVE SIDE
PLANK FACE
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G - PLANK OPTIONS AND DETAILS
3" = 1'-0"
1
BACK OF PLANK ISOMETRIC
3" = 1'-0"
2
FRONT OF PLANK ISOMETRIC
16MM SPACING BETWEEN KERFS SHOWN. 8MM, 24MM, AND 32MM OPTIONS AVAILABLE
SHEET NUMBER
2
START PATTERN
FROM ROOM CENTER
15
16
" H.D. T-BAR GRID
MAINS BY OTHER
(2'-0" O.C. TYP)
℄
JOINTS TO LAND
ON T-GRID
JOINTS TO LAND
ON T-GRID
START PATTERN
FROM ROOM CENTER
15
16
" H.D. T-BAR GRID
MAINS BY OTHER
(2'-0" O.C. TYP)
℄
1/2" = 1'-0"
1
TYPICAL PATTERN RCP (OPTION 1 - CENTERED ON PLANK)
1/2" = 1'-0"
2
TYPICAL PATTERN RCP (OPTION 2 - CENTERED ON REVEAL)
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - FRAMING
SHEET NUMBER
3
JOINT CENTERED
ON GRID
T&G GRID CLIP
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM (AS SPECIFIED)
AUDITION PLANK
1
4
" X 1
1
4
" DOWEL
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM (AS SPECIFIED)
ACOUSTICAL BACKER
RECOMMENDED
1 1/2" = 1'-0"
1
ISOMETRIC VIEW - TYP.
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - ISOMETRIC
SHEET NUMBER
4
FIELD CUT MITERS TYP.
TRIM
AUDITION PLANK
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
8" MAXIMUM
CANTILEVER
4" T
YP
6" M
AX
HANGER
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
4" T
YP
6" M
AX
T-GRID (BY OTHER)
SUSPENSION
(BY OTHER)
15
16
" HEAVY
DUTY T-GRID
(BY OTHER)
FIELD CUT
T&G GRID CLIP
1" = 1'-0"
1
CLOUD VERTICAL TRIM PLAN
3" = 1'-0"
2
TRIM @ EDGE - FRONT SECTION
3" = 1'-0"
3
TRIM @ EDGE - SIDE SECTION
2
3
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - TRIM CONDITIONS
SHEET NUMBER
5
8" MAXIMUM
CANTILEVER
SUSPENSION
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
SUSPENSION
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
8" MAXIMUM
CANTILEVER
SUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDEDSUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
3" = 1'-0"
1
FLOATING - SIDE SECTION
3" = 1'-0"
2
FLOATING - FRONT SECTION
3" = 1'-0"
3
WALL ANGLE ABOVE - SIDE SECTION
3" = 1'-0"
4
WALL ANGLE ABOVE - FRONT SECTION
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL
SHEET NUMBER
6
8" MAXIMUM
CANTILEVER
SUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
SUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
3" = 1'-0"
1
WALL ANGLE BELOW - SIDE SECTION
3" = 1'-0"
2
WALL ANGLE BELOW - FRONT SECTION
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL
SHEET NUMBER
7
AUDITION PLANK
INDEPENDENTLY SUPPORTED
SPRINKLER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
SPRINKLER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
SUPPORT BRACKET
FASTENED W/ SCREWS
TO PLANKS (BY OTHER)
PIPE HANGER ANCHORED
TO BUILDING STRUCTURE
(BY OTHER)
SUSPENSION (BY OTHER)
1 1/2" = 1'-0"
1
SPRINKLER HEAD DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
SPRINKLER HEAD DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - SPRINKLER HEAD DETAIL
SHEET NUMBER
8
AUDITION PLANK
INDEPENDENTLY SUPPORTED
CAN LIGHT: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
CAN LIGHT: FIELD CUT
PENETRATION
TRIM RING (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
1 1/2" = 1'-0"
1
CAN LIGHT DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
CAN LIGHT DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - CAN LIGHT DETAIL
SHEET NUMBER
9
AUDITION PLANK
INDEPENDENTLY SUPPORTED
PENDANT LIGHT: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
PENDANT LIGHT: FIELD CUT
PENETRATION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM PLATE
(BY OTHER)
T&G GRID CLIP
SUSPENSION
(BY OTHER)
1 1/2" = 1'-0"
1
PENDANT LIGHT DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
PENDANT LIGHT DETAIL - SECTION DETAIL
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - PENDANT LIGHT DETAIL
SHEET NUMBER
10
AUDITION PLANK
INDEPENDENTLY SUPPORTED
SPEAKER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
SPEAKER: FIELD CUT
PENETRATION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM PLATE
(BY OTHER)
T&G GRID CLIP
SUSPENSION
(BY OTHER)
1 1/2" = 1'-0"
1
RECESSED SPEAKER DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
RECESSED SPEAKER DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - RECESSED SPEAKER DETAIL
SHEET NUMBER
11
AUDITION PLANK
INDEPENDENTLY SUPPORTED
AUDITION LIGHT: FIELD CUT
PENETRATION
BRACKETS REQ'D
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
AUDITION LIGHT: FIELD CUT
PENETRATION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM PLATE
(BY OTHER)
SUSPENSION
(BY OTHER)
1" = 1'-0"
1
LINEAR LIGHT DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
LINEAR LIGHT DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - LINEAR LIGHT DETAIL
SHEET NUMBER
12
AUDITION PLANK
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH,
SUPPORT BRACKETS ARE
NEEDED (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY
SUPPORTED
DIFFUSER: FIELD CUT
PENETRATION
INDEPENDENTLY
SUPPORTED
DUCTWORK
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
DIFFUSER: FIELD CUT
PENETRATION
1 1/2" = 1'-0"
1
LINEAR DIFFUSER DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
LINEAR DIFFUSER DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - DIFFUSER DETAIL
SHEET NUMBER
13
SCRAP
15
16
" HD
T-GRID BACKER
RAILS TO BE BACK
SCREWED IN FIELD
ACCESS PANEL
SEAM (FIELD CUT)
A
C
C
E
S
S
P
A
N
E
L
T&G GRID CLIP
RIP TONGUE IN FIELD
RIP TONGUE IN FIELD
T&G GRID CLIP
SCREWED TO
BACKER
RIP TONGUE
IN FIELD
FIXED PLANK
(BACKSCREWED
TO CEILING GRID)
BACKER RAILS
(BY OTHER)
FIXED PLANK
(BACKSCREWED
TO CEILING GRID)
RIP TONGUE
IN FIELD
1 1/2" = 1'-0"
1
ACCESS PANEL DETAIL
3" = 1'-0"
2
ACCESS PANEL SECTION
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G CEILING SYSTEM - ACCESS PANEL
SHEET NUMBER
14
TYP. WALL ASSEMBLY
(BY OTHER)
T&G DIRECT ATTACH CLIP
SCREWED TO FURRING
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
LINEAR HORIZONTAL WALL SECTION
1' = 1'-0"
2
DIRECT ATTACHMENT CLIP
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - HORIZONTAL WALL SECTION
SHEET NUMBER
16
16"
O.C. TYP
JOINTS TO LAND ON FRAMING
START PATTERN FROM BASE
BOARD (FIELD RIP TONGUE)
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
FURRING (BY OTHER)
24"
O.C. TYP JOINTS TO LAND ON FRAMING
START PATTERN FROM BASE
BOARD (FIELD RIP TONGUE)
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
FURRING (BY OTHER)
1/2" = 1'-0"
1
TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 16 INCH SPACING
1/2" = 1'-0"
2
TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 24 INCH SPACING
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - HORIZONTAL WALL PATTERN
SHEET NUMBER
17
ALL JOINTS
CENTERED
ON FURRING
TYP. WALL ASSEMBLY
(BY OTHER)
16 GA. FINISH
NAIL (BY OTHER)
T&G DIRECT
ATTACHMENT
CLIP SCREWED TO
FRAMING IN FIELD
TRIM TO COINCIDE W/
FURRING THICKNESS
FASTENED W/ FINISH
NAIL (OPTIONAL)
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
1 1/2" = 1'-0"
1
HORIZONTAL WALL SYSTEM ISOMETRIC
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - HORIZONTAL ISOMETRIC
SHEET NUMBER
18
TYP. WALL
SYSTEM (BY
OTHER)
FIELD CUT END
3
4
" TRIM FASTENED
W/ FINISH NAIL AND
PUTTIED IN FIELD
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
FURRING (BY OTHER) FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL BACKER RECOMMENDED
BETWEEN FURRING
3
4
" TRIM
FASTENED W/
FINISH NAIL
AND PUTTIED
IN FIELD
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
HORIZONTAL WALL PLAN @ TRIM
3" = 1'-0"
2
HORIZONTAL WALL ELEVATION @ TRIM
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - HORIZONTAL TRIM CONDITIONS
SHEET NUMBER
19
TYP. WALL SYSTEM
(BY OTHER)
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
LINEAR VERTICAL WALL SECTION
1' = 1'-0"
2
DIRECT ATTACHMENT CLIP
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - VERTICAL WALL SECTION
SHEET NUMBER
20
BASE AS SCHEDULED
(BY OTHER)
START PATTERN
FROM ROOM CENTER
JOINTS TO LAND
ON FRAMING
FACE NAILED AND
PUTTIED IN FIELD @
BASE
HORIZONTAL
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
℄
NOTE: START PATTERN
O.C. WITH REVEAL OR
PLANK - WHICHEVER
LEAVES THE LARGEST
POSSIBLE BOARD
WIDTH @ PERIMETER
BASE AS SCHEDULED
(BY OTHER)
START PATTERN
FROM ROOM CENTER
JOINTS TO LAND
ON FRAMING
FACE NAILED AND
PUTTIED IN FIELD @
BASE
HORIZONTAL
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
℄
1/2" = 1'-0"
1
VERTICAL WALL PATTERN 1
1/2" = 1'-0"
2
VERTICAL WALL PATTERN 2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - VERTICAL WALL PATTERN
SHEET NUMBER
21
ALL JOINTS
CENTERED
ON FRAMING
T&G DIRECT
ATTACHMENT CLIP
SCREWED TO
FRAMING IN FIELD
TYP. WALL SYSTEM
(BY OTHER)
16 GA. FINISH
NAIL (BY OTHER)
HORIZONTAL FURRING
OVER DRYWALL (BY
OTHER): ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
TRIM TO COINCIDE W/
FURRING THICKNESS
FASTENED W/ FINISH
NAIL (OPTIONAL)
1 1/2" = 1'-0"
1
VERTICAL WALL SYSTEM ISOMETRIC
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - VERTICAL ISOMETRIC
SHEET NUMBER
22
TYP. WALL SYSTEM
(BY OTHER)
3
4
" TRIM FASTENED W/
FINISH NAIL AND PUTTIED
IN FIELD BY OTHER
FURRING (BY OTHER) FASTENED TO STRUCTURE IN
FIELD: ACOUSTICAL BACKER RECOMMENDED
BETWEEN FURRING
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
3
4
" TRIM FASTENED W/
FINISH NAIL AND PUTTIED
IN FIELD BY OTHER
HORIZONTAL FURRING
(BY OTHER) FASTENED
TO STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
VERTICAL WALL PLAN @ TRIM
3" = 1'-0"
2
VERTICAL WALL ELEVATION @ TRIM
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - VERTICAL TRIM CONDITIONS
SHEET NUMBER
23
LIGHT SWITCH PENETRATION FIELD CUT
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
TYP. WALL SYSTEM (BY OTHER)
LIGHT SWITCH PENETRATION FIELD CUT
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
LIGHT SWITCH DETAIL - ELEVATION
3" = 1'-0"
2
LIGHT SWITCH DETAIL - SECTION
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - LIGHT SWITCH DETAIL
SHEET NUMBER
24
OUTLET PENETRATION FIELD CUT
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
OUTLET PENETRATION FIELD CUT
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
TYP. WALL SYSTEM (BY OTHER)
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
OUTLET DETAIL - ELEVATION
3" = 1'-0"
2
OUTLET DETAIL - SECTION
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - OUTLET DETAIL
SHEET NUMBER
25
BASE AS SCHEDULED (BY OTHER)
FACE NAIL & PUTTY IN FIELD
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
BASE AS SCHEDULED (BY OTHER)
FACE NAIL & PUTTY IN FIELD
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
BASEBOARD DETAIL - ELEVATION
3" = 1'-0"
2
BASEBOARD DETAIL - SECTION
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - BASEBOARD DETAIL
SHEET NUMBER
26
FIELD CUT
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
FACE NAIL IN FIELD
TYPICAL WALL ASSEMBLY (BY OTHER)
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
OUTSIDE CORNER
MOULDING
FIELD CUT
FACE NAIL IN FIELD
T&G DIRECT ATTACH CLIP
SCREWED TO FURRING
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
3/4"
3/4"
2"
2"
OUTSIDE
CORNER
MOULDING
8' LENGTHS
TYPICAL
3" = 1'-0"
1
VERTICAL PLANK INSIDE CORNER PLAN
3" = 1'-0"
2
VERTICAL PLANK OUTSIDE CORNER PLAN
1' = 1'-0"
3
SECTION (WDOCT)
3
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G WALL SYSTEM - WALL-TO-WALL CORNER
SHEET NUMBER
27
BACKSCREW
IN FIELD
FIELD CUT
FACE NAIL
IN FIELD
T&G DIRECT
ATTACH CLIP
SCREWED TO
FRAMING
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
SUSPENSION
(BY OTHER)
T&G GRID CLIP
WALL ANGLE
(BY OTHER)
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
WALL-TO-CEILING TRANSITION
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G SYSTEM - WALL-TO-CIELING TRANSITION
SHEET NUMBER
28
EVERY 6TH PLANK TO BE
BACKSCREWED IN FIELD
FIELD CUT LAP JOINT
SUSPENSION (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
BACKSREW IN FIELD
FACE NAIL IN FIELDT&G DIRECT ATTACH
CLIP SCREWED TO
FRAMING
* ACOUSTICAL BACKER RECOMMENDED
FIELD CUT LAP JOINT
SUSPENSION (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
HORIZONTAL FURRING
(BY OTHER) FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
T&G GRID CLIP
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
* ACOUSTICAL BACKER
RECOMMENDED
3" = 1'-0"
1
HORIZONTAL WALL-TO-VAULTED CEILING
3" = 1'-0"
2
VERTICAL WALL-TO-VAULTED CEILING
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G SYSTEM - WALL-TO-VAULTED CEILING
SHEET NUMBER
29
EVERY 6TH PLANK TO BE
BACKSCREWED IN FIELD
BACKSCREW IN FIELD
SUSPENSION (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
MITER IN FIELD
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
MITER IN FIELD
SUSPENSION
(BY OTHER)
T&G GRID CLIP
BACKSCREW IN FIELD
* ACOUSTICAL BACKER RECOMMENDED
3" = 1'-0"
1
HORIZONTAL VAULTED CEILING RETURN
3" = 1'-0"
2
VERTICAL VAULTED CEILING RETURN
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G SYSTEM - VAULTED CEILING RETURN
SHEET NUMBER
30
SUSPENSION
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
USE AUDITION PLANK
FOR FIELD CUT TRIM
FIELD-CUT TRIM OPTION
TO BE FACE-NAILED
AND PUTTIED IN FIELD
* ACOUSTICAL BACKER RECOMMENDED
USE AUDITION PLANK
FOR FIELD CUT TRIM
SUSPENSION
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
FIELD-CUT TRIM OPTION
TO BE FACE-NAILED
AND PUTTIED IN FIELD
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
3" = 1'-0"
1
HORIZONTAL VAULTED CEILING PEAK
3" = 1'-0"
2
VERTICAL VAULTED CEILING PEAK
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/27/2018
AUDITION T&G SYSTEM - VAULTED CEILING PEAKS
SHEET NUMBER
31
SUSPENSION (BY
OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
BACKSCREWED IN FIELD
T&G GRID CLIP
FIELD CUT LAP JOINT
* ACOUSTICAL BACKER RECOMMENDED
FIELD CUT LAP JOINT
SUSPENSION (BY
OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
BACKSCREWED IN FIELD
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
3" = 1'-0"
1
HORIZONTAL VAULTED CEILING PEAK - LAP JOINT
3" = 1'-0"
2
VERTICAL VAULTED CEILING PEAK - LAP JOINT
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2018
123 Columbia Court North, Chaska,
Minnesota 55318 P. 800.527.6253
BMH4/23/2018
AUDITION T&G SYSTEM - VAULTED CEILING PEAKS
SHEET NUMBER
32