8
1. THE STRUCTURAL DOCUMENT (DRAWINGS & SPECIFICATIONS) - MUST NOT BE USED WITHOUT THE CONSTRUCTION DOCUMENT OF OTHER DISCIPLINES. COORDINATION BETWEEN STRUCTURAL DOCUMENT AND OTHER DISCIPLINE'S DOCUMENT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR RESPONSIBLE FOR THE WORK. 2. EXISTING CONDITIONS SHOWN ON THE STRUCTURAL DOCUMENT ARE CONCEPTUAL & MUST BE VERIFIED IN THE FIELD BY GENERAL CONTRACTOR PRIOR TO DETAILING, FABRICATION, & CONSTRUCTION OF RELATED WORK. 3. ALL ITEMS REQUIRED BY OTHER DISCIPLINE'S WORK & IMPACTING THE STRUCTURAL WORK SUCH AS CASTING OF ANCHORS, SLEEVES, CONDUITS, OPENINGS, SUPPORTS FOR & BRACING FOR NON-STRUCTURAL COMPONENT SHALL BE IDENTIFIED BY SUBCONTRACTORS RESPONSIBLE FOR SUCH WORK & SUBMITTED WITH DETAILS FOR STRUCTURAL ENGINEER'S APPROVAL. 4. THE SEOR IS NOT RESPONSIBLE FOR MEANS, METHODS, AND SEQUENCE OF WORK. ALL TEMPORARY BRACING, SHORING, COMPLIANCE WITH OSHA REGULATIONS & SOILS REPORT AND GENERAL STABILITY OF INDIVIDUAL STRUCTURAL COMPONENT DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 5. WHERE SPECIFIC DETAILS ARE NOT IDENTIFIED ON THE STRUCTURAL PLANS, REFER TO TYPICAL DETAILS AND UTILIZE INDUSTRY STANDARD PRACTICE AS IDENTIFIED IN SPECIFIED CODES, REGULATIONS, AND STANDARDS. GENERAL NOTES FOUNDATION 1. SOIL BEARING PRESSURE --- 1500 PSF (ASSUMED - VERIFY IN FIELD) CONCRETE 1. DETAILING, FABRICATION AND REINFORCING STEEL -- PER LATEST CRSI MANUAL OF STANDARD PRACTICE. 2. REINFORCING STEEL -- ASTM A615, GRADE 60. 3. MINIMUM 28 DAY CONCRETE STRENGTH -- 4000 PSI, UNLESS NOTED OTHERWISE. 4. LAP FOR CONTINUOUS REINFORCING BARS -- 60 DIAMETERS, BUT NOT LESS THAN 2'-0" LAP BOTTOM REINFORCING AT SUPPORT. 5. MINIMUM CONCRETE COVER FOR REINFORCING BARS: SLABS (EXCEPT SLABS ON GRADE) . . . 1" BEAMS AND COLUMNS . . . . . . . . . 1 1/2" TO TIES OR STIRRUPS WALLS . . . . . . . . . . . 1 1/2" EXTERIOR FACE, 1" INTERIOR FACE CONCRETE CAST AGAINST EARTH . . . . . 3" 6. BLOCKING, SLEEVES, BOLTS, AND ANCHORS REQUIRED TO BE SET IN CONCRETE OR TO BE ATTACHED TO STEEL -- PER ARCHITECTURAL AND MECHANICAL DRAWINGS. SITEWORK 1. BACKFILL SHALL BE FREE OF DEBRIS AND LARGE ROCKS. 2. SLOPE GRADE AWAY FROM BUILDING AT 1 INCH PER FOOT MINIMUM FOR A DISTANCE OF 8'-0" MINIMUM OR TO SWALE. ADDITIONAL VERTICAL UNITS MAY BE REQUIRED TO ACCOUNT FOR SETTLEMENT OF BACKFILL AT THE IMMEDIATE PERIMETER OF THE FOUNDATION. 3. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUTS. DOWNSPOUTS DISCHARGE SHALL BE DIRECTED AWAY FROM THE FOUNDATION. 4. FINISHED GRADES AT BUILDING TO BE A MINIMUM OF 8" BELOW TOP OF FOUNDATION FOR WOOD FRAME WALLS AND 6" MINIMUM BELOW FOR FULL MASONRY WALLS. 5. SILTATION AND EROSION CONTROL MEASURES MUST BE PROVIDED TO PREVENT SILTATION/EROSION FROM LEAVING THE CONSTRUCTION SITE. “TOP BARS” ARE DEFINED AS ANY BAR WITH MORE THAN 12” OF CONCRETE CAST BELOW THE BAR, SEE NOTE 4 IN TABLE NOTES CONCRETE: 1. CONCRETE SHALL CONFORM WITH THE REQUIREMENTS SET FORTH IN A.C.I. 301 AND SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH AND DENSITY, IN ACCORDANCE WITH THE FOLLOWING: A. FOR MAXIMUM COARSE AGGREGATE SIZE INDICATED, USE THE FOLLOWING AGGREGATE SIZE NUMBERS PER A.S.T.M. C33: 3/8” - #8 AGGREGATE ¾” - #67 AGGREGATE 1” - #57 AGGREGATE 1 ½” - #467 AGGREGATE B. TOTAL AIR CONTENT LIMITS INCLUDE BOTH ENTRAINED AND ENTRAPPED AIR +/- 1 ½%. “N” IN COLUMN INDICATES ADDITION OF ENTRAINED AIR NOT PERMITTED. C. ABBREVIATIONS FOR REQUIRED ADMIXTURES AS FOLLOWS: AE – AIR-ENTRAINED ADMIXTURE WR – WATER REDUCING ADMIXTURE D. MAXIMUM SHRINKAGE FOR SLAB ON GRADE SHALL BE LIMITED TO ¼” PER 100 FOOT. 2. REINFORCING SHALL CONFORM TO A.S.T.M. A615, GR. 60, INCLUDING TIES AND STIRRUPS. BARS REQUIRING WELDING OR FIELD BENDING SHALL BE A.S.T.M. A706, GRADE 60. 3. WELDED WIRE FABRIC SHALL CONFORM TO A.S.T.M. A185. 4. LAP SPLICES SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS NOTED OTHERWISE. WHERE CLASSES ARE NOT CALLED OUT ON DRAWING, USE CLASS “B” SPLICES. SPLICES f’c = 4000 P.S.I., Fy = 60,000 P.S.I. INTENDED USE 28-DAY STRENGTH Fc (KSI) GRADE BEAMS, TIE BEAMS AND BASEMENT WALLS ALL CONCRETE NOT OTHERWISE SPECIFIED DRILLED PIERS FOOTINGS COLUMNS STRUCTURAL SLABS AND BEAMS CONCRETE EXPOSED TO DEICERS SLABS ON METAL DECK INTERIOR TOPPING SLABS INTERIOR SLAB ON GRADE AE, WR 4 CONCRETE DENSITY MAX. W/C (INCLUDING FLY ASH) MIN. CEMENT MATL. (#/CY INCLUDING FLY ASH) MAXIMUM AGGREGATE (IN) SLUMP LIMITS (IN)(+0"-2") TOTAL AIR LIMITS (%0) (B) REQUIRED ADMIXTURES (C) 145 0.48 564 1 7 6 AE 4 145 0.48 564 1 4 - - 4 145 0.48 564 3/4 4 5 145 0.48 611 4 4 145 0.48 564 4 4 145 0.40 564 4 6 3.5 110 0.50 541 5 3.5 145 0.50 541 4 4 145 0.50 564 1 4 4 145 0.40 564 4 6 3/4 3/4 3/4 3/4 3/4 3/4 - - N - - N - - - - - - - TABLE NOTES 1. TABLES ARE BASED A.C.I. 318. WHERE CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED IS AT LEAST 2 BAR DIAMETERS AND THE CLEAR COVER AT LEAST 1 BAR DIAMETER, USE CASE 1. USE CASE 2 FOR OTHER BAR ARRANGEMENTS. 2. ALL SPLICES TO BE CLASS “B” TENSION SPLICE UNLESS OTHERWISE NOTED. 3. SPLICE PLAIN WIRE FABRIC BY LAPPING ONE FULL MESH SPACE PLUS 2 INCHES. 4. FOR TOP BARS, MULTIPLY LENGTHS IN TABLE BY 1.3. 5. FOR EPOXY COATED REINFORCEMENT, MULTIPLY LENGTHS IN TABLE BY 1.3 FOR TOP BARS AND 1.5 FOR COVER LESS THAN 3db OR CLEAR LESS THAN 6db, MULTIPLY LENGTHS IN TABLE BY 1.2 FOR ALL OTHER EPOXY COATED REINFORCEMENT. 6. FOR LIGHT CONCRETE, MULTIPLY LENGTHS IN TABLE BY 1.3. 7. COMPRESSION DOWEL EMBEDMENT: 22 BAR DIAMETERS. STANDARD TENSION LAP SPLICE, GRADE 60 CLASS A, AB, LAP SPLICE LENGTH (INCHES) f’c = 3,000 P.S.I. f’c = 4,000 P.S.I. f’c = 5,000 P.S.I BAR SIZE CLASS CASE A B #3 . 1 16 2 16 16 16 1 A B 1 16 16 16 16 1 A B 1 16 1616 16 1 #4 . 16 16 16 16 16 16 16 16 16 1616 16 #5 . 16 16 16 16 16 16 16 16 16 1616 16 #6 . 16 16 16 16 16 16 16 16 16 1616 16 #7 . 16 16 16 16 16 16 16 16 16 1616 16 #8 . 16 16 16 16 16 16 16 16 16 1616 16 #9 . 16 16 16 16 16 16 16 16 16 1616 16 #10 . 16 16 16 16 16 16 16 16 16 1616 16 #11 . 16 16 16 16 16 16 16 16 16 1616 16 2 2 2 2 2 COMPRESSION LAP SCHEDULE LAP LENGTH (INCHES) f’c = 3,000 P.S.I. OR GREATER BAR SIZE MIN. LAP #3 12 #4 15 #5 19 #6 22 #7 26 #8 29 #9 33 #10 37 #11 41 STRUCTURAL STEEL: 1. STEEL SHALL CONFORM TO THE FOLLOWING GRADES: ALL WIDE FLANGE (U.N.O.), A992 GRADE 50 (FY=50) ALL CHANNEL, ANGLE, BASE PLATES, CONNECTION PLATES (U.N.O.), A36 (FY=36) STRUCTURAL PIPE: A53 (FY=35) STRUCTURAL HSS RECTANGULAR TUBE: A500 GRADE B (FY=46) STRUCTURAL HSS ROUND TUBE: A500 GRADE B (FY=42) 2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE A.S.C.I. CODE OF STANDARD PRACTICE (1992), EXCEPT AS MODIFIED IN THESE NOTES AND THE PROJECT SPECIFICATIONS. 3. CONNECTIONS MAY BE BOLTED OR WELDED. THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN OF CONNECTIONS NOT DESIGNED ON THE DRAWINGS. GENERALLY, CONNECTIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE SCHEMATIC AND ARE ONLY INTENDED TO SHOW THE RELATIONSHIP OF MEMBERS CONNECTED. ANY CONNECTION THAT IS SHOWN OR IS NOT COMPLETELY DETAILED ON THE STRUCTURAL DRAWINGS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF THE PROJECT, RETAINED BY THE FABRICATOR. COMPLETELY DETAILED MEANS THE FOLLOWING INFORMATION IS SHOWN ON THE DETAIL: A. ALL PLATE DIMENSIONS AND GRADES. B. ALL WELD SIZES, LENGTHS, PITCHES, AND RETURNS. C. ALL HOLE SIZES AND SPACINGS. D. NUMBER AND TYPES OF BOLTS: WHERE BOLTS ARE SHOWN BUT NO NUMBER IS GIVEN, THE CONNECTION HAS NOT BEEN COMPLETELY DETAILED. E. WHERE PARTIAL INFORMATION IS GIVEN, IT SHALL BE THE MINIMUM REQUIREMENT FOR THE CONNECTION. PRIOR TO FABRICATION, PROVIDE (FOR RECORD COPY) DESIGN CALCULATIONS FOR TYPICAL BEAM CONNECTIONS, ALL PRIMARY BRACING AND HANGER CONNECTIONS, SIGNED AND SEALED BY A PREOFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT SHALL BE SUBMITTED TO THE ENGINEER. CONNECTION DESIGN FORCES: A. BEAMS, GREATER OF: 55% OF TOTAL ALLOWABLE UNIFORM LOAD CAPACITY FROM A.I.S.C. 9TH EDITION TABLES FOR ALLOWABLE LOADS ON BEAMS, Wc/L. REACTIONS SHOWN ON DRAWINGS. 10 KIPS. MOMENT CONNECTIONS INDICATED ON THE DRAWINGS THUS: {-< }-{ >-} DEISGN FOR MOMENT SHOWN OR, IF NOT SHOWN, DEVELOP MOMENT CAPACITY OF MEMBER WITH fb=0.66 FY. MAINTAIN TENSION INDICATED OF COLUMNS, DIAGONALS AND MEMBERS SUBJECT TO TENSION AT BOLT HOLES, NOTCHES, OR COPES. CONNECTION FORCE NOTATION: P = AXIAL FORCE IN KIPS: (+) TENSION, (-) COMPRESSION V OR [ ] = SHEAR IN KIPS M = MOMENT IN FOOT KIPS T = TORSION IN FOOT KIPS LOADS SHOWN INCLUDE COMPENSATION FOR CODE PERMITTED LOAD REDUCTIONS FOR CONNECTION DESIGN. THE MINIMUM PLATE THICKNESS SHALL BE 3/8”. BOLTED CONNECTIONS: MINIMUM BOLT DIAMETER = ¾” SLIP CRITICAL CONNECTIONS OF A3255C OR A490SC BOLTS SHALL BE USED FOR ALL BOLTED CONNECTIONS OF BRACING MEMBERS, MOMENT CONNECTIONS, CANTILEVERS, AND AS SHOWN ON THE DRAWINGS. OVERSIZED AND LONG-SLOTTED HOLES ARE ALLOWED FOR SLIP CRITICAL CONNECTIONS. ALL OTHER BOLTED CONNECTIONS SHALL BE BEARING TYPE USING A325N OR A490N BOLTS. OVERSIZED HOLES AND LONG-SLOTTED HOLES ARE NOT ALLOWED UNLESS SHOWN ON THE DRAWINGS. A307 BOLTS MAY BE USED WHERE INDICATED ON THE DRAWINGS. PROTRUDING BOLT HEADS, SHAFTS OR NUTS SHALL NOT EXTEND INTO NOR PROHIBIT THE APPLICATION OF ARCHITECTURAL FINISHED AND THEY SHALL NOT EXTEND INTO NOT PROHIBIT THE PLACEMENT OF STEEL DECKING TO THE CORRECT LINE AND ELEVATION. THE FABRICATOR IS RESPONSIBLE FOR VERFYING THE TENSION CAPACITY OF AXIALLY LOADED MEMBERS AFTER A SECTION IS REDUCED FOR BOLT HEADS. MEMBER SIZE MAY BE INCREASED OR CONNECTION PLATES ADDED AS REQUIRED. SHOP DRAWINGS SHALL INDICATE THE TYPE OF BOLT USED IN EACH CONNECTION AND THE ALLOWABLE VALUES USED FOR THE VARIOUS BOLT TYPES. B. C. D. E. 5. 6. A. B. C. D. E. F. G. WELDED CONNECTIONS: WELDS ARE CONTINUOUS UNLESS NOTED. ALL FILLET WELDS: A.I.S.C. MINIMUM BUT NOT LESS THAN 1.4” UNLESS NOTED OTHERWISE. ALL WELDING SHALL BE IN ACCORDANCE WITH THE CURRENT “STRUCTURAL WELDING CODE” (A.W.S. DI.1) PUBLISHED BY THE AMERICAN WELDING SOCIETY. ELECTRODES FOR WELDING SHALL COMPLY WITH THE REQUIREMENTS OF TABLE 4.1.1 OF (A.W.S. DI.1). ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED OTHERWISE. SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON THE DRAWINGS, IS PROHIBITED WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. NO CHANGES IN SIZE OR POSITION OF THE STRUCTURAL ELEMENTS SHALL BE ADE AND HOLES, SLOTS, CUTS, ETC., ARE NOT PERMITTED THROUGH ANY MEMBER UNLESS THEY ARE DETAILED ON THE APPROVED SHOP DRAWINGS. NO FINAL BOLTING OR WELDING SHALL BE MADE UNTIL AS MUCH OF THE STRUCTURE AS WILL BE STIFFENED THEREBY HAS BEEN PROPERLY ALIGNED. UNLESS NOTED OTHERWISE, BEAMS SHALL BEAR 8” MINIMUM ON CONCRETE OR MASONRY. ANCHOR BEAMS TO MASONRY OR CONCRETE WITH 2-3/4” DIA. ANCHOR BOLTS OR WELDED TO EMBED PLATE. FABRICATE ALL BEAMS WITH THE MILL CAMBER UP. SHEAR STUDS: CONFORM TO A.W.S. DI-1-98, SHOP WELD EXCEPT WHERE APPLIED THROUGH METAL DECK. HEADED STUDS SHALL CONFORM TO A.W.S. DI-1-98, SHOP WELD EXCEPT WHERE APPLIED THROUGH METAL DECK. HEADED STUDS SHALL CONFORM TO A.S.T.M. A108, GRADE 1015, WELDABLE (Fy = 65 K.S.I.). WHERE FIREPROOFING IS REQUIRED, ADJUST FIREPROOFING THICKNESS BASED ON MEMER SIZES. SEE ARCHITECTURAL DRAWINGS FOR FIREPROOFING REQUIREMENTS AND THICKNESS. THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN AND DETAILING OF STEEL STAIRS. STAIRS SHOWN ON THE STRUCTURAL DRAWINGS ARE SCHMETIS AND ARE ONLY INTENDED TO SHOW THE RELATIONSHIP OF MEMBERS CONNECTED. STAIRS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT, RETAINED BY THE FABRICATOR. A. B. C. D. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. POST-INSTALLED MECHANICAL ANCHORS: 1. POST-INSTALLED MECHANICAL ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER OF RECORD PRIOR TO USING POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST-IN ANCHORS. CARE SHALL BE GIVEN TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED PER MANUFACTURER’S INSTRUCTIONS. DO NOT CUT EXISTING REINFORCING. 2. THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING OR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. UNLESS SPECIFIED OTHERWISE, ANCHORS SHALL BE EMBEDDED IN THE APPROPRIATE SUBSTRATE WITH A MINIMUM EMBEDMENT OF 8 TIMES THE NOMINAL ANCHOR DIAMETER OR THE EMBEDMENT DEPTH REQUIRED TO SUPPORT THE INTENDED LOAD. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE LISTED BELOW, SHALL BE SUBMITTED TO THE ENGINEER WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE PROJECT IS LOCATED, SHOWING THAT THE SUBSTITUTED PRODUCTS WILL ACHIEVE AN EQUIVALENT CAPACITY. 3. UNLESS OTHERWISE NOTED IN THE DETAILS, ANCHORS SHALL BE: CONCRETE EXPANSION ANCHORS: ALL CONCRETE EXPANSION ANCHORS SHALL MEET THE REQUIREMENTS OF A.C.I. 318, APPENDIX D AND SHALL BE ACCEPTABLE FOR BOTH CRACKED AND UN-CRACKEDCONCRETE. “STRONG-BOLT” BY SIMPSON STRONG-TIE CO. (ISS-ES ESR-1771) “KWIK BOLT TZ” BY HILTI, INC. (ICC-ES ESR-1917) “HSL HEAVY DUTY SLEEVE ANCHOR” BY HILTI, INC. (ICC- ES ESR-1546) “KWIK BOLT 3” BY HILTI, INC. UNCRACKED ONLY (ICC-ES ESR-2303) GROUTED MASONRY EXPANSION ANCHORS: “WEDGE-ALL” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-1396) “KWIK BOLT 3” BY HILTI, INC. (ICC-ES ESR-1385) 4. ADHERE TO MANUFACTURERS REQUIREMENTS FOR ANCHOR SPACING AND LOCATIONS. CONCRETE SCREW ANCHORS: ALL SCREW ANCHORS SHALL BE INSTALLED IN DRY, INTERIOR NON-CORROSIVE ENVIRONMENTS OR FOR TEMPORARY OUTDOOR APPLICATIONS. “TITEN HD” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-2713) CRACKED AND UN-CRACKED CONCRETE. “KWIK HUS EZ AND EZ-1” BY ILTI, INC. (ICC-ES ESR-3027) MASONRY SCREW ANCHORS: ALL SCREW ANCHORS SHALL BE INSTALLED IN DRY, INTERIOR NON-CORROSIVE ENVIRONMENTS OR FOR TEMPORARY OUTDOOR APPLICATIONS. “TITEN HD” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-2713) “HUS-H SCREW ANCHOR” BY HILTI, INC. (ICC-ES ESR-2369) 5. SPECIAL INSPECTION SHALL BE PROVIDED IN ACCORDANCE WITH THE ICC-ES REPORT AND AS PRESCRIBED BY THE APPLICABLE BUILDING CODE. C. WOOD TRUSS MEMBERS: 1. TRUSSES SHOWN ON PLANS ARE FOR CONFIGURATION ONLY. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH MISSOURI PROFESSIONAL ENGINEERS SEAL SHOWING ACTUAL MEMBER STRESSES AND JOINT PLATE SIZES CONFORMING TO LOADING FIGURES CONSTRUCTED BY THE TRUSS SUPPLIER. TRUSS LAYOUT/PLAN DRAWINGS SHALL BE SUBMITTED. 2. ALL WOOD TRUSS TO WOOD TRUSS (OR WOOD GIRDER TRUSS) CONNECTIONS SHALL BE BY WOOD TRUSS SUPPLIER. SHOP DRAWINGS SHALL BE SUBMITTED FOR THESES CONNECTIONS, TYPICAL. 3. TEMPORARY AND PERMANENT WOOD TRUSS BRACING/BRIDGING LOCATION AND SIZE SHALL BE DESIGNED AND INDICATED BY THE TRUSS MANUFACTURER, TYP. 4. LIVE LOAD DEFLECTION DESIGN LIMITS SHALL NOT BE GREATER THAN THE FOLLOWING: a. ROOF TRUSSES, VERTICAL 1/360 TIMES PROJECTED SPAN. b. FLOOR TRUSSES, VERTICAL 1/480 TIMES SPAN LENGTH. 5. PROVIDE 1/8" OF CAMBER FOR EACH 6'-0" OF TRUSS SPAN UNO. 1. ALL BEAMS, HEADERS, LINTELS AND COLUMNS SHALL BE CONNECTED WITH APPROPRIATE METAL STANDARDS OF SIMPSON STRONG-TIE. ATTACH ANCHORS TO WOOD FRAMING IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 2. MISCELLANEOUS FASTENER CONNECTIONS SHALL BE IN ACCORDANCE WITH THE NAILING SCHEDULE OF THE APPROPRIATE BUILDING CODE. WHERE ROUGH CARPENTRY IS EXPOSED TO WEATHER, IN GROUND CONTACT, OR IN AREAS OF HIGH RELATIVE HUMIDITY, PROVIDE HOT-DIP-ZINC COATED FASTENERS PER ASTM A153 OR AISI TYPE 304 STAINLESS STEEL FASTENERS. 3. ALL MULTIPLE-PLY MICROLAM MEMBERS SHALL BE INTERCONNECTED PER MANUFACTURER INSTRUCTIONS FOR SIDE-LOADED BEAMS. 4. PRESERVATIVE PRESSURE TREAT LUMBER AND PLYWOOD WITH WATER-BORNE PRESERVATIVES TO COMPLY WITH AWPA C2 AND C9 RESPECTIVELY, AND WITH REQUIREMENTS INDICATED BELOW. D. NOTES: a. PRESSURE TREAT ABOVE-GROUND ITEMS WITH WATER-BORNE PRESERVATIVE TO A MINIMUM RETENTION OF 0.25 PCF, FOR INTERIOR USES, AFTER TREATMENT, KILN-DRY LUMBER AND PLYWOOD TO A MAXIMUM MOISTURE CONTENT, RESPECTIVELY, OF 18 PERCENT AND 15 PERCENT, TREAT INDICATED ITEMS AND THE FOLLOWING: 1. WOOD CANTS, NAILERS, CURBS, EQUIPMENT, SUPPORT BASES, BLOCKING STRIPPING AND SIMILAR MEMBERS IN CONNECTION WITH ROOFING, FLASHING, VAPOR BARRIERS AND WATERPROOFING. 2. WOOD SILLS, SLEEPERS, BLOCKING, FURRING, STRIPPING AND SIMILAR CONCEALED MEMBERS IN CONTACT WITH MASINRY OR CONCRETE. b. COMPLETE FABRICATION OF TREATED ITEMS PRIOR TO TREATMENT, WHERE POSSIBLE. IF CUT AFTER TREATMENT, COAT CUT SURFACES TO COMPLY WITH AWPA M4. INSPECT EACH PIECE OF LUMBER OR PLYWOOD AFTER FRYING AND DISCARD DAMAGED OR DEFECTIVE PIECES. WOOD FRAMING (ROUGH CARPENTRY, WOOD RPODUCTS AND WOOD TRUSSES) A. DESIGN CODES: 1. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS), LATEST ADOPTION. 2. INSTALL ROUGH CARPENTRY WORK TO COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) TIMBER CONSTRUCTION (TC) MANUAL, LATEST ADOPTION AND RECOMMENDATIONS OF THE PRODUCT MAUFACTURER. B. MATERIAL STRENGTHS: 1. ALL WOOD STICK FRAMING SHALL BE SOUTHERN YELLOW PINE, NO. 1 GRADE (GRADED UNDER WWPA RULES) OR BETTER. 2. LUMBER FOR MISCELLANEOUS USES MAY BE "STANDARD" GRADE LIGHT-FRAMING-SIZE LUMBER OF ANY SPECIES FOR SUPPORT OF OTHER CONSTRUCTION INCLUDING ROOFTOP EQUIPMENT AND SUPPORT BASES, CANT STRIPS, BUCKS, NAILERS, BLOCKING, FURRING, GROUND, STRIPPING AND SIMILAR MEMBERS. 3. ULTRA LAM COLUMNS AS MANUFACTURED BY VALLEY LUMBER CO. INC. 4. FASTENERS: a. NAILS, WIRE BRADS AND STAPLES: ASTM F547 b. POWER DRIVEN FASTENERS: NATIONAL EVALUATION REPORT NER-272 c. WOOD SCREWS: ANSI B18.6.1 d. LAG BOLTS: ANSI B18.2.1 e. BOLTS: ASTM A307, GRADE A OR ASTM A36 Date Revisions OWNER: SEAL: CIVIL ENGINEER OFFICE: (636) 797-8425 CELL: (314) 952-5038 10785 BUSINESS 21, SUITE A HILLSBORO, MISSOURI 63050 [email protected] CERTIFICATE OF AUTHORITY 0975 BACON COMMERCIAL DESIGN STEVEN J. BACON 100 BAILEY ROAD #A CRYSTAL CITY, MO 63019 (636) 933-0007 05/07/19 ISSUE FOR BID S1.1
Transcript
Page 1: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

1. THE STRUCTURAL DOCUMENT (DRAWINGS & SPECIFICATIONS) - MUST NOT BE USED WITHOUT

THE CONSTRUCTION DOCUMENT OF OTHER DISCIPLINES. COORDINATION BETWEEN

STRUCTURAL DOCUMENT AND OTHER DISCIPLINE'S DOCUMENT IS THE RESPONSIBILITY OF

THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR RESPONSIBLE FOR THE WORK.

2. EXISTING CONDITIONS SHOWN ON THE STRUCTURAL DOCUMENT ARE CONCEPTUAL & MUST

BE VERIFIED IN THE FIELD BY GENERAL CONTRACTOR PRIOR TO DETAILING, FABRICATION, &

CONSTRUCTION OF RELATED WORK.

3. ALL ITEMS REQUIRED BY OTHER DISCIPLINE'S WORK & IMPACTING THE STRUCTURAL WORK

SUCH AS CASTING OF ANCHORS, SLEEVES, CONDUITS, OPENINGS, SUPPORTS FOR & BRACING

FOR NON-STRUCTURAL COMPONENT SHALL BE IDENTIFIED BY SUBCONTRACTORS

RESPONSIBLE FOR SUCH WORK & SUBMITTED WITH DETAILS FOR STRUCTURAL ENGINEER'S

APPROVAL.

4. THE SEOR IS NOT RESPONSIBLE FOR MEANS, METHODS, AND SEQUENCE OF WORK. ALL

TEMPORARY BRACING, SHORING, COMPLIANCE WITH OSHA REGULATIONS & SOILS REPORT

AND GENERAL STABILITY OF INDIVIDUAL STRUCTURAL COMPONENT DURING CONSTRUCTION

IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.

5. WHERE SPECIFIC DETAILS ARE NOT IDENTIFIED ON THE STRUCTURAL PLANS, REFER TO

TYPICAL DETAILS AND UTILIZE INDUSTRY STANDARD PRACTICE AS IDENTIFIED IN SPECIFIED

CODES, REGULATIONS, AND STANDARDS.

GENERAL NOTES

FOUNDATION

1. SOIL BEARING PRESSURE --- 1500 PSF (ASSUMED - VERIFY IN FIELD)

CONCRETE

1. DETAILING, FABRICATION AND REINFORCING STEEL -- PER LATEST CRSI MANUAL OF

STANDARD PRACTICE.

2. REINFORCING STEEL -- ASTM A615, GRADE 60.

3. MINIMUM 28 DAY CONCRETE STRENGTH -- 4000 PSI, UNLESS NOTED OTHERWISE.

4. LAP FOR CONTINUOUS REINFORCING BARS -- 60 DIAMETERS, BUT NOT LESS

THAN 2'-0" LAP BOTTOM REINFORCING AT SUPPORT.

5. MINIMUM CONCRETE COVER FOR REINFORCING BARS:

SLABS (EXCEPT SLABS ON GRADE) . . . 1"

BEAMS AND COLUMNS . . . . . . . . . 1 1/2" TO TIES OR STIRRUPS

WALLS . . . . . . . . . . . 1 1/2" EXTERIOR FACE, 1" INTERIOR FACE

CONCRETE CAST AGAINST EARTH . . . . . 3"

6. BLOCKING, SLEEVES, BOLTS, AND ANCHORS REQUIRED TO BE SET IN CONCRETE

OR TO BE ATTACHED TO STEEL -- PER ARCHITECTURAL AND MECHANICAL

DRAWINGS.

SITEWORK

1. BACKFILL SHALL BE FREE OF DEBRIS AND LARGE ROCKS.

2. SLOPE GRADE AWAY FROM BUILDING AT 1 INCH PER FOOT MINIMUM FOR A DISTANCE OF 8'-0"

MINIMUM OR TO SWALE. ADDITIONAL VERTICAL UNITS MAY BE REQUIRED TO ACCOUNT FOR

SETTLEMENT OF BACKFILL AT THE IMMEDIATE PERIMETER OF THE

FOUNDATION.

3. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUTS. DOWNSPOUTS DISCHARGE

SHALL BE DIRECTED AWAY FROM THE FOUNDATION.

4. FINISHED GRADES AT BUILDING TO BE A MINIMUM OF 8" BELOW TOP OF FOUNDATION FOR

WOOD FRAME WALLS AND 6" MINIMUM BELOW FOR FULL MASONRY WALLS.

5. SILTATION AND EROSION CONTROL MEASURES MUST BE PROVIDED TO PREVENT

SILTATION/EROSION FROM LEAVING THE CONSTRUCTION SITE.

“TOP BARS” ARE DEFINED AS ANY BAR WITH MORE THAN 12” OF

CONCRETE CAST BELOW THE BAR, SEE NOTE 4 IN TABLE NOTES

CONCRETE:

1. CONCRETE SHALL CONFORM WITH THE REQUIREMENTS SET FORTH IN

A.C.I. 301 AND SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH AND

DENSITY, IN ACCORDANCE WITH THE FOLLOWING:

A. FOR MAXIMUM COARSE AGGREGATE SIZE INDICATED, USE THE

FOLLOWING AGGREGATE SIZE NUMBERS PER A.S.T.M.

C33: 3/8” - #8 AGGREGATE

¾” - #67 AGGREGATE

1” - #57 AGGREGATE

1 ½” - #467 AGGREGATE

B. TOTAL AIR CONTENT LIMITS INCLUDE BOTH ENTRAINED AND

ENTRAPPED AIR +/- 1 ½%. “N” IN COLUMN INDICATES ADDITION OF

ENTRAINED AIR NOT PERMITTED.

C. ABBREVIATIONS FOR REQUIRED ADMIXTURES AS FOLLOWS:

AE – AIR-ENTRAINED ADMIXTURE

WR – WATER REDUCING ADMIXTURE

D. MAXIMUM SHRINKAGE FOR SLAB ON GRADE SHALL BE LIMITED TO

¼” PER 100 FOOT.

2. REINFORCING SHALL CONFORM TO A.S.T.M. A615, GR. 60, INCLUDING

TIES AND STIRRUPS. BARS REQUIRING WELDING OR FIELD BENDING

SHALL BE A.S.T.M. A706, GRADE 60.

3. WELDED WIRE FABRIC SHALL CONFORM TO A.S.T.M. A185.

4. LAP SPLICES SHALL BE IN ACCORDANCE WITH THE FOLLOWING

TABLE, UNLESS NOTED OTHERWISE. WHERE CLASSES ARE NOT

CALLED OUT ON DRAWING, USE CLASS “B” SPLICES.

SPLICES f’c = 4000 P.S.I., Fy = 60,000 P.S.I.

INTENDED USE

28

-D

AY

S

TR

EN

GT

H F

c (K

SI)

GRADE BEAMS, TIE BEAMS

AND BASEMENT WALLS

ALL CONCRETE NOT

OTHERWISE SPECIFIED

DRILLED PIERS

FOOTINGS

COLUMNS

STRUCTURAL SLABS AND BEAMS

CONCRETE EXPOSED TO DEICERS

SLABS ON METAL DECK

INTERIOR TOPPING SLABS

INTERIOR SLAB ON GRADE

AE, WR

4

CO

NC

RE

TE

D

EN

SIT

Y

MA

X. W

/C

(IN

CL

UD

IN

G

FL

Y A

SH

)

MIN

. C

EM

EN

T M

AT

L. (#

/C

Y

IN

CL

UD

IN

G F

LY

A

SH

)

MA

XIM

UM

A

GG

RE

GA

TE

(IN

)

SL

UM

P L

IM

IT

S (IN

)(+

0"-2

")

TO

TA

L A

IR

L

IM

IT

S (%

0) (B

)

RE

QU

IR

ED

A

DM

IX

TU

RE

S (C

)

145 0.48 564 1 7 6 AE

4 145 0.48 564 1 4 - -

4 145 0.48 564 3/4 4

5 145 0.48 611 4

4 145 0.48 564 4

4 145 0.40 564 4 6

3.5 110 0.50 541 5

3.5 145 0.50 541 4

4 145 0.50 564 1 4

4 145 0.40 564 4 6

3/4

3/4

3/4

3/4

3/4

3/4

-

-

N

-

-

N

-

-

-

-

-

-

-

TABLE NOTES

1. TABLES ARE BASED A.C.I. 318.

WHERE CLEAR SPACING OF BARS

BEING DEVELOPED OR SPLICED

IS AT LEAST 2 BAR DIAMETERS

AND THE CLEAR COVER AT LEAST

1 BAR DIAMETER, USE CASE 1.

USE CASE 2 FOR OTHER BAR

ARRANGEMENTS.

2. ALL SPLICES TO BE

CLASS “B” TENSION SPLICE

UNLESS OTHERWISE NOTED.

3. SPLICE PLAIN WIRE FABRIC BY

LAPPING ONE FULL MESH SPACE

PLUS 2 INCHES.

4. FOR TOP BARS, MULTIPLY

LENGTHS IN TABLE BY 1.3.

5. FOR EPOXY COATED

REINFORCEMENT, MULTIPLY

LENGTHS IN TABLE BY 1.3 FOR

TOP BARS AND 1.5 FOR COVER

LESS THAN 3db OR CLEAR LESS

THAN 6db, MULTIPLY LENGTHS IN

TABLE BY 1.2 FOR ALL OTHER

EPOXY COATED

REINFORCEMENT.

6. FOR LIGHT CONCRETE, MULTIPLY

LENGTHS IN TABLE BY 1.3.

7. COMPRESSION DOWEL

EMBEDMENT: 22 BAR DIAMETERS.

STANDARD TENSION LAP SPLICE, GRADE 60

CLASS A, AB, LAP SPLICE LENGTH (INCHES)

f’c = 3,000 P.S.I. f’c = 4,000 P.S.I. f’c = 5,000 P.S.I

BAR SIZE CLASS

CASE

A B

#3 .

1

16

2

16 16 16

1

A B

1

16 16 16 16

1

A B

1

16 1616 16

1

#4 .16 16 16 16 16 16 16 16 16 1616 16

#5 .16 16 16 16 16 16 16 16 16 1616 16

#6 .16 16 16 16 16 16 16 16 16 1616 16

#7 .16 16 16 16 16 16 16 16 16 1616 16

#8 .16 16 16 16 16 16 16 16 16 1616 16

#9 .16 16 16 16 16 16 16 16 16 1616 16

#10 .16 16 16 16 16 16 16 16 16 1616 16

#11 .16 16 16 16 16 16 16 16 16 1616 16

2 2 2 2 2

COMPRESSION LAP SCHEDULE

LAP LENGTH (INCHES)

f’c = 3,000 P.S.I. OR GREATER

BAR SIZE MIN. LAP

#3 12

#4 15

#5 19

#6 22

#7 26

#8 29

#9 33

#10 37

#11 41

STRUCTURAL STEEL:

1. STEEL SHALL CONFORM TO THE FOLLOWING GRADES:

ALL WIDE FLANGE (U.N.O.), A992 GRADE 50 (FY=50)

ALL CHANNEL, ANGLE, BASE PLATES, CONNECTION PLATES (U.N.O.),

A36 (FY=36)

STRUCTURAL PIPE: A53 (FY=35)

STRUCTURAL HSS RECTANGULAR TUBE: A500 GRADE B (FY=46)

STRUCTURAL HSS ROUND TUBE: A500 GRADE B (FY=42)

2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND

ERECTED IN ACCORDANCE WITH THE A.S.C.I. CODE OF STANDARD

PRACTICE (1992), EXCEPT AS MODIFIED IN THESE NOTES AND THE

PROJECT SPECIFICATIONS.

3. CONNECTIONS MAY BE BOLTED OR WELDED. THE FABRICATOR IS

RESPONSIBLE FOR THE DESIGN OF CONNECTIONS NOT DESIGNED

ON THE DRAWINGS. GENERALLY, CONNECTIONS SHOWN ON THE

STRUCTURAL DRAWINGS ARE SCHEMATIC AND ARE ONLY

INTENDED TO SHOW THE RELATIONSHIP OF MEMBERS CONNECTED.

ANY CONNECTION THAT IS SHOWN OR IS NOT COMPLETELY

DETAILED ON THE STRUCTURAL DRAWINGS SHALL BE DESIGNED BY

A PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF THE

PROJECT, RETAINED BY THE FABRICATOR. COMPLETELY DETAILED

MEANS THE FOLLOWING INFORMATION IS SHOWN ON THE DETAIL:

A. ALL PLATE DIMENSIONS AND GRADES.

B. ALL WELD SIZES, LENGTHS, PITCHES, AND RETURNS.

C. ALL HOLE SIZES AND SPACINGS.

D. NUMBER AND TYPES OF BOLTS: WHERE BOLTS ARE

SHOWN BUT NO NUMBER IS GIVEN, THE CONNECTION HAS

NOT BEEN COMPLETELY DETAILED.

E. WHERE PARTIAL INFORMATION IS GIVEN, IT SHALL BE THE

MINIMUM REQUIREMENT FOR THE CONNECTION.

PRIOR TO FABRICATION, PROVIDE (FOR RECORD COPY) DESIGN

CALCULATIONS FOR TYPICAL BEAM CONNECTIONS, ALL PRIMARY

BRACING AND HANGER CONNECTIONS, SIGNED AND SEALED BY A

PREOFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE

PROJECT SHALL BE SUBMITTED TO THE ENGINEER.

CONNECTION DESIGN FORCES:

A. BEAMS, GREATER OF:

55% OF TOTAL ALLOWABLE UNIFORM LOAD CAPACITY

FROM A.I.S.C. 9TH EDITION TABLES FOR ALLOWABLE LOADS

ON BEAMS, Wc/L.

REACTIONS SHOWN ON DRAWINGS.

10 KIPS.

MOMENT CONNECTIONS INDICATED ON THE DRAWINGS

THUS: {-< }-{ >-} DEISGN FOR MOMENT SHOWN OR, IF NOT

SHOWN, DEVELOP MOMENT CAPACITY OF MEMBER WITH

fb=0.66 FY.

MAINTAIN TENSION INDICATED OF COLUMNS, DIAGONALS

AND MEMBERS SUBJECT TO TENSION AT BOLT HOLES,

NOTCHES, OR COPES.

CONNECTION FORCE NOTATION:

P = AXIAL FORCE IN KIPS: (+) TENSION, (-) COMPRESSION

V OR [ ] = SHEAR IN KIPS

M = MOMENT IN FOOT KIPS

T = TORSION IN FOOT KIPS

LOADS SHOWN INCLUDE COMPENSATION FOR CODE

PERMITTED LOAD REDUCTIONS FOR CONNECTION DESIGN.

THE MINIMUM PLATE THICKNESS SHALL BE 3/8”.

BOLTED CONNECTIONS:

MINIMUM BOLT DIAMETER = ¾”

SLIP CRITICAL CONNECTIONS OF A3255C OR A490SC BOLTS

SHALL BE USED FOR ALL BOLTED CONNECTIONS OF

BRACING MEMBERS, MOMENT CONNECTIONS,

CANTILEVERS, AND AS SHOWN ON THE DRAWINGS.

OVERSIZED AND LONG-SLOTTED HOLES ARE ALLOWED FOR

SLIP CRITICAL CONNECTIONS.

ALL OTHER BOLTED CONNECTIONS SHALL BE BEARING

TYPE USING A325N OR A490N BOLTS. OVERSIZED HOLES

AND LONG-SLOTTED HOLES ARE NOT ALLOWED UNLESS

SHOWN ON THE DRAWINGS.

A307 BOLTS MAY BE USED WHERE INDICATED ON THE

DRAWINGS.

PROTRUDING BOLT HEADS, SHAFTS OR NUTS SHALL NOT

EXTEND INTO NOR PROHIBIT THE APPLICATION OF

ARCHITECTURAL FINISHED AND THEY SHALL NOT EXTEND

INTO NOT PROHIBIT THE PLACEMENT OF STEEL DECKING TO

THE CORRECT LINE AND ELEVATION.

THE FABRICATOR IS RESPONSIBLE FOR VERFYING THE

TENSION CAPACITY OF AXIALLY LOADED MEMBERS AFTER A

SECTION IS REDUCED FOR BOLT HEADS. MEMBER SIZE MAY

BE INCREASED OR CONNECTION PLATES ADDED AS

REQUIRED.

SHOP DRAWINGS SHALL INDICATE THE TYPE OF BOLT USED

IN EACH CONNECTION AND THE ALLOWABLE VALUES USED

FOR THE VARIOUS BOLT TYPES.

B.

C.

D.

E.

5.

6.

A.

B.

C.

D.

E.

F.

G.

WELDED CONNECTIONS:

WELDS ARE CONTINUOUS UNLESS NOTED.

ALL FILLET WELDS: A.I.S.C. MINIMUM BUT NOT LESS THAN 1.4”

UNLESS NOTED OTHERWISE.

ALL WELDING SHALL BE IN ACCORDANCE WITH THE

CURRENT “STRUCTURAL WELDING CODE” (A.W.S. DI.1) PUBLISHED BY

THE AMERICAN WELDING SOCIETY. ELECTRODES FOR WELDING SHALL

COMPLY WITH THE REQUIREMENTS OF TABLE 4.1.1 OF (A.W.S. DI.1).

ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS

NOTED OTHERWISE.

SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON THE DRAWINGS, IS

PROHIBITED WITHOUT WRITTEN APPROVAL OF THE ARCHITECT.

NO CHANGES IN SIZE OR POSITION OF THE STRUCTURAL ELEMENTS SHALL

BE ADE AND HOLES, SLOTS, CUTS, ETC., ARE NOT PERMITTED THROUGH ANY

MEMBER UNLESS THEY ARE DETAILED ON THE APPROVED SHOP DRAWINGS.

NO FINAL BOLTING OR WELDING SHALL BE MADE UNTIL AS MUCH OF THE

STRUCTURE AS WILL BE STIFFENED THEREBY HAS BEEN PROPERLY

ALIGNED.

UNLESS NOTED OTHERWISE, BEAMS SHALL BEAR 8” MINIMUM ON CONCRETE

OR MASONRY. ANCHOR BEAMS TO MASONRY OR CONCRETE

WITH 2-3/4” DIA. ANCHOR BOLTS OR WELDED TO EMBED PLATE.

FABRICATE ALL BEAMS WITH THE MILL CAMBER UP.

SHEAR STUDS: CONFORM TO A.W.S. DI-1-98, SHOP WELD EXCEPT WHERE

APPLIED THROUGH METAL DECK.

HEADED STUDS SHALL CONFORM TO A.W.S. DI-1-98, SHOP WELD EXCEPT

WHERE APPLIED THROUGH METAL DECK. HEADED STUDS SHALL CONFORM

TO A.S.T.M. A108, GRADE 1015, WELDABLE (Fy = 65 K.S.I.).

WHERE FIREPROOFING IS REQUIRED, ADJUST FIREPROOFING THICKNESS

BASED ON MEMER SIZES. SEE ARCHITECTURAL DRAWINGS FOR

FIREPROOFING REQUIREMENTS AND THICKNESS.

THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN AND DETAILING OF

STEEL STAIRS. STAIRS SHOWN ON THE STRUCTURAL DRAWINGS ARE

SCHMETIS AND ARE ONLY INTENDED TO SHOW THE RELATIONSHIP OF

MEMBERS CONNECTED. STAIRS SHALL BE DESIGNED BY A PROFESSIONAL

ENGINEER REGISTERED IN THE STATE OF THE PROJECT, RETAINED BY THE

FABRICATOR.

A.

B.

C.

D.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

POST-INSTALLED MECHANICAL ANCHORS:

1. POST-INSTALLED MECHANICAL ANCHORS SHALL ONLY BE USED WHERE

SPECIFIED ON THE DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL

FROM THE ENGINEER OF RECORD PRIOR TO USING POST-INSTALLED

ANCHORS FOR MISSING OR MISPLACED CAST-IN ANCHORS. CARE SHALL BE

GIVEN TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED

AND CLEANED PER MANUFACTURER’S INSTRUCTIONS. DO NOT CUT EXISTING

REINFORCING.

2. THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S

REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING OR ALL OF

THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF

RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE

CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO

THE COMMENCEMENT OF INSTALLING ANCHORS. UNLESS SPECIFIED

OTHERWISE, ANCHORS SHALL BE EMBEDDED IN THE APPROPRIATE

SUBSTRATE WITH A MINIMUM EMBEDMENT OF 8 TIMES THE NOMINAL ANCHOR

DIAMETER OR THE EMBEDMENT DEPTH REQUIRED TO SUPPORT THE

INTENDED LOAD. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN

THOSE LISTED BELOW, SHALL BE SUBMITTED TO THE ENGINEER WITH

CALCULATIONS THAT ARE PREPARED AND SEALED BY A PROFESSIONAL

ENGINEER, REGISTERED IN THE STATE WHERE PROJECT IS LOCATED,

SHOWING THAT THE SUBSTITUTED PRODUCTS WILL ACHIEVE AN EQUIVALENT

CAPACITY.

3. UNLESS OTHERWISE NOTED IN THE DETAILS, ANCHORS SHALL BE:

CONCRETE EXPANSION ANCHORS:

ALL CONCRETE EXPANSION ANCHORS SHALL MEET THE REQUIREMENTS OF

A.C.I. 318, APPENDIX D AND SHALL BE ACCEPTABLE FOR BOTH CRACKED

AND UN-CRACKEDCONCRETE.

“STRONG-BOLT” BY SIMPSON STRONG-TIE CO. (ISS-ES ESR-1771)

“KWIK BOLT TZ” BY HILTI, INC. (ICC-ES ESR-1917)

“HSL HEAVY DUTY SLEEVE ANCHOR” BY HILTI, INC. (ICC- ES ESR-1546)

“KWIK BOLT 3” BY HILTI, INC. UNCRACKED ONLY (ICC-ES ESR-2303)

GROUTED MASONRY EXPANSION ANCHORS:

“WEDGE-ALL” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-1396)

“KWIK BOLT 3” BY HILTI, INC. (ICC-ES ESR-1385)

4. ADHERE TO MANUFACTURERS REQUIREMENTS FOR ANCHOR SPACING AND

LOCATIONS.

CONCRETE SCREW ANCHORS:

ALL SCREW ANCHORS SHALL BE INSTALLED IN DRY, INTERIOR

NON-CORROSIVE ENVIRONMENTS OR FOR TEMPORARY OUTDOOR

APPLICATIONS.

“TITEN HD” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-2713)

CRACKED AND UN-CRACKED CONCRETE.

“KWIK HUS EZ AND EZ-1” BY ILTI, INC. (ICC-ES ESR-3027)

MASONRY SCREW ANCHORS:

ALL SCREW ANCHORS SHALL BE INSTALLED IN DRY, INTERIOR

NON-CORROSIVE ENVIRONMENTS OR FOR TEMPORARY OUTDOOR

APPLICATIONS.

“TITEN HD” BY SIMPSON STRONG-TIE CO. (ICC-ES ESR-2713)

“HUS-H SCREW ANCHOR” BY HILTI, INC. (ICC-ES ESR-2369)

5. SPECIAL INSPECTION SHALL BE PROVIDED IN ACCORDANCE WITH THE ICC-ES

REPORT AND AS PRESCRIBED BY THE APPLICABLE BUILDING CODE.

C. WOOD TRUSS MEMBERS:

1. TRUSSES SHOWN ON PLANS ARE FOR CONFIGURATION ONLY. CONTRACTOR

SHALL SUBMIT SHOP DRAWINGS WITH MISSOURI PROFESSIONAL ENGINEERS

SEAL SHOWING ACTUAL MEMBER STRESSES AND JOINT PLATE SIZES

CONFORMING TO LOADING FIGURES CONSTRUCTED BY THE TRUSS SUPPLIER.

TRUSS LAYOUT/PLAN DRAWINGS SHALL BE SUBMITTED.

2. ALL WOOD TRUSS TO WOOD TRUSS (OR WOOD GIRDER TRUSS) CONNECTIONS

SHALL BE BY WOOD TRUSS SUPPLIER. SHOP DRAWINGS SHALL BE SUBMITTED

FOR THESES CONNECTIONS, TYPICAL.

3. TEMPORARY AND PERMANENT WOOD TRUSS BRACING/BRIDGING LOCATION AND

SIZE SHALL BE DESIGNED AND INDICATED BY THE TRUSS MANUFACTURER, TYP.

4. LIVE LOAD DEFLECTION DESIGN LIMITS SHALL NOT BE GREATER THAN THE

FOLLOWING:

a. ROOF TRUSSES, VERTICAL 1/360 TIMES PROJECTED SPAN.

b. FLOOR TRUSSES, VERTICAL 1/480 TIMES SPAN LENGTH.

5. PROVIDE 1/8" OF CAMBER FOR EACH 6'-0" OF TRUSS SPAN UNO.

1. ALL BEAMS, HEADERS, LINTELS AND COLUMNS SHALL BE CONNECTED WITH

APPROPRIATE METAL STANDARDS OF SIMPSON STRONG-TIE. ATTACH ANCHORS

TO WOOD FRAMING IN ACCORDANCE WITH MANUFACTURERS

RECOMMENDATIONS.

2. MISCELLANEOUS FASTENER CONNECTIONS SHALL BE IN ACCORDANCE WITH THE

NAILING SCHEDULE OF THE APPROPRIATE BUILDING CODE. WHERE ROUGH

CARPENTRY IS EXPOSED TO WEATHER, IN GROUND CONTACT, OR IN AREAS OF

HIGH RELATIVE HUMIDITY, PROVIDE HOT-DIP-ZINC COATED FASTENERS PER ASTM

A153 OR AISI TYPE 304 STAINLESS STEEL FASTENERS.

3. ALL MULTIPLE-PLY MICROLAM MEMBERS SHALL BE INTERCONNECTED PER

MANUFACTURER INSTRUCTIONS FOR SIDE-LOADED BEAMS.

4. PRESERVATIVE PRESSURE TREAT LUMBER AND PLYWOOD WITH WATER-BORNE

PRESERVATIVES TO COMPLY WITH AWPA C2 AND C9 RESPECTIVELY, AND WITH

REQUIREMENTS INDICATED BELOW.

D. NOTES:

a. PRESSURE TREAT ABOVE-GROUND ITEMS WITH WATER-BORNE PRESERVATIVE TO

A MINIMUM RETENTION OF 0.25 PCF, FOR INTERIOR USES, AFTER TREATMENT,

KILN-DRY LUMBER AND PLYWOOD TO A MAXIMUM MOISTURE CONTENT,

RESPECTIVELY, OF 18 PERCENT AND 15 PERCENT, TREAT INDICATED ITEMS AND

THE FOLLOWING:

1. WOOD CANTS, NAILERS, CURBS, EQUIPMENT, SUPPORT BASES, BLOCKING

STRIPPING AND SIMILAR MEMBERS IN CONNECTION WITH ROOFING,

FLASHING, VAPOR BARRIERS AND WATERPROOFING.

2. WOOD SILLS, SLEEPERS, BLOCKING, FURRING, STRIPPING AND SIMILAR

CONCEALED MEMBERS IN CONTACT WITH MASINRY OR CONCRETE.

b. COMPLETE FABRICATION OF TREATED ITEMS PRIOR TO TREATMENT, WHERE

POSSIBLE. IF CUT AFTER TREATMENT, COAT CUT SURFACES TO COMPLY WITH

AWPA M4. INSPECT EACH PIECE OF LUMBER OR PLYWOOD AFTER FRYING AND

DISCARD DAMAGED OR DEFECTIVE PIECES.

WOOD FRAMING (ROUGH CARPENTRY, WOOD RPODUCTS AND WOOD TRUSSES)

A. DESIGN CODES:

1. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS), LATEST

ADOPTION.

2. INSTALL ROUGH CARPENTRY WORK TO COMPLY WITH AMERICAN INSTITUTE OF

TIMBER CONSTRUCTION (AITC) TIMBER CONSTRUCTION (TC) MANUAL, LATEST

ADOPTION AND RECOMMENDATIONS OF THE PRODUCT MAUFACTURER.

B. MATERIAL STRENGTHS:

1. ALL WOOD STICK FRAMING SHALL BE SOUTHERN YELLOW PINE, NO. 1 GRADE

(GRADED UNDER WWPA RULES) OR BETTER.

2. LUMBER FOR MISCELLANEOUS USES MAY BE "STANDARD" GRADE

LIGHT-FRAMING-SIZE LUMBER OF ANY SPECIES FOR SUPPORT OF OTHER

CONSTRUCTION INCLUDING ROOFTOP EQUIPMENT AND SUPPORT BASES, CANT

STRIPS, BUCKS, NAILERS, BLOCKING, FURRING, GROUND, STRIPPING AND SIMILAR

MEMBERS.

3. ULTRA LAM COLUMNS AS MANUFACTURED BY VALLEY LUMBER CO. INC.

4. FASTENERS:

a. NAILS, WIRE BRADS AND STAPLES: ASTM F547

b. POWER DRIVEN FASTENERS: NATIONAL EVALUATION REPORT NER-272

c. WOOD SCREWS: ANSI B18.6.1

d. LAG BOLTS: ANSI B18.2.1

e. BOLTS: ASTM A307, GRADE A OR ASTM A36

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S1.1

AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
NO SCALE
Page 2: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

TYPICAL CONCRETE WALL REINFORCINGDETAILS

TYPICAL FOOTING STEP

TYPICAL INTERIOR COLUMN TYPICAL SECTION AT DOOR

SLAB ON GRADE JOINT PATTERN

ANCHOR ROD SCHEDULE

TYPICAL FOUNDATION WALL JOINTS

TYPICAL FOUNDATION DOWELING DETAIL

TYPICAL EPOXY DOWELING DETAIL PIPE TRENCH PERPENDICULAR TO FOUNDATION DETAIL TYPICAL EPOXY ANCHOR DETAIL THROUGH FOUNDATION WALL DETAIL PIPE PENETRATION

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S2.1

AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
STEEL COLUMN SEE SCHEDULE
AutoCAD SHX Text
LAP
AutoCAD SHX Text
LAP
AutoCAD SHX Text
BOND BREAKER
AutoCAD SHX Text
CORNER BARS TO MATCH WALL REINFORCING
AutoCAD SHX Text
TWO LAYERS
AutoCAD SHX Text
ONE LAYER
AutoCAD SHX Text
ONE LAYER
AutoCAD SHX Text
TWO LAYERS
AutoCAD SHX Text
ALT. HK.
AutoCAD SHX Text
CORNERS
AutoCAD SHX Text
INTERSECTIONS
AutoCAD SHX Text
T/ FTG. SEE PLAN
AutoCAD SHX Text
MAX.
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
DOWELS TO MATCH FOOTING REINFORCING
AutoCAD SHX Text
1
AutoCAD SHX Text
1 MIN.
AutoCAD SHX Text
FIN. SLAB
AutoCAD SHX Text
1 1/2" NON-SHRINK GROUT
AutoCAD SHX Text
T/ FTG EL. SEE PLAN
AutoCAD SHX Text
ANCHOR RODS SEE SCHEDULE
AutoCAD SHX Text
SEE FTG. SCHEDULE FOR SIZE & REINF.
AutoCAD SHX Text
#4x48" DWLS @ 18"cc
AutoCAD SHX Text
TOP OF FTG. SEE PLAN
AutoCAD SHX Text
COARSE GRANULAR FILL
AutoCAD SHX Text
8"
AutoCAD SHX Text
FACE OF BRICK BEYONDBEYOND
AutoCAD SHX Text
SEE ARCH DWGS. FOR DOOR DETAILS
AutoCAD SHX Text
EXTEND VERTS. AND BEND DOWN IN FIELD
AutoCAD SHX Text
FIN. FLR. SLAB
AutoCAD SHX Text
1 1/2" DEEP X 2 1/2" HIGH CONT. KEY
AutoCAD SHX Text
RIGID INSULATION PER ARCH. DWGS.
AutoCAD SHX Text
ALTERNATE HOOKS
AutoCAD SHX Text
SIDEWALK SLAB W/6x6 W1.4xW1.4 WWF
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
2-#4 CONT.
AutoCAD SHX Text
DEPTH MIN.
AutoCAD SHX Text
#4@18"cc
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
(SAWN JOINT)
AutoCAD SHX Text
1/2" DIA. SMOOTH DWL. X 2'-6" @ 18"CC (OR RIBBED BARS W/ BOND BREAKER)
AutoCAD SHX Text
W.W.F. IS CONTINUOUS THRU JOINT
AutoCAD SHX Text
W.W.F. IS DISCONTINUOUS AT JOINT
AutoCAD SHX Text
(FORMED JOINT)
AutoCAD SHX Text
COORDINATE C.J. LOCATIONS WITH ARCH.
AutoCAD SHX Text
CONSTRUCTION JOINT
AutoCAD SHX Text
ROD THREADED 6" AT TOP AND 3" AT BOTTOM. 4" MIN. PROJECTION.
AutoCAD SHX Text
"L"
AutoCAD SHX Text
UNLESS OTHERWISE SPECIFIED, ALL ANCHOR RODS SHALL BE GRADE 36
AutoCAD SHX Text
SEE THE COLUMN SCHEDULE FOR ANCHOR ROD SIZES REQUIRED ON THIS PROJECT
AutoCAD SHX Text
SEE SPECIFIC DETAILS FOR SPECIAL EMBEDMENT LENGTHS AND ROD SIZES DUE TO HIGH LOADING CONDITIONS.
AutoCAD SHX Text
NUT & WASHER
AutoCAD SHX Text
T/CONC
AutoCAD SHX Text
TACK
AutoCAD SHX Text
NUT
AutoCAD SHX Text
T/NUT
AutoCAD SHX Text
MIN. PROJ.
AutoCAD SHX Text
F1554 ANCHOR ROD SCHEDULE
AutoCAD SHX Text
ROD SIZE
AutoCAD SHX Text
3/4" DIA.
AutoCAD SHX Text
1" DIA
AutoCAD SHX Text
1 1/4" & 1 1/2" DIA.
AutoCAD SHX Text
9"
AutoCAD SHX Text
1'-3"
AutoCAD SHX Text
AS REQ'D.
AutoCAD SHX Text
FROM GRADE DOWN TO FTG. PROVIDE STYROFOAM FILLER IN WALL NOTCH ON EARTH SIDE.
AutoCAD SHX Text
EARTH SIDE
AutoCAD SHX Text
TERMINATE ALL REINFORCING @ CONSTRUCTION JOINT
AutoCAD SHX Text
2x6 CONT. KEY
AutoCAD SHX Text
PROVIDE VOLCLAY STRIP FULL HEIGHT AT ALL CONSTRUCTION JOINTS (TYP.).
AutoCAD SHX Text
TERMINATE 50% OF HORIZ. REINFORCING @ CONSTRUCTION JOINT.
AutoCAD SHX Text
@ CONTROL JOINT
AutoCAD SHX Text
@ CONSTRUCTION JOINT
AutoCAD SHX Text
3/4"x3/4" REVEAL TYP.
AutoCAD SHX Text
@ 20-0"OC; 10'-0" FROM CORNER
AutoCAD SHX Text
@ 20'-0"OC
AutoCAD SHX Text
(2)-#5 DWLS x 2'-6" LONG DRILL & EPOXY GROUT INTO EXIST FOOTING (6" MIN. EMBED)
AutoCAD SHX Text
#4 DWLSx2'-6" LONG @ 12" O.C. EA. WAY DRILL & EPOXY GROUT INTO EXIST FOUNDATION (6" MIN EMBED)
AutoCAD SHX Text
T/C PER PLAN
AutoCAD SHX Text
EXISTING CONSTRUCTION
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SEE TYPICAL EPOXY DOWELING DETAIL THIS SHEET FOR DOWELING PROCEDURE
AutoCAD SHX Text
REINFORCING BAR PER PLAN AND/OR PER SECTION
AutoCAD SHX Text
EXISTING CONCRETE OR OTHER BASE MATERIAL
AutoCAD SHX Text
DRILLED HOLE-FILL WITH EPOXY GROUT
AutoCAD SHX Text
1. DRILL HOLE TO THE REQUIRED DEPTH; APPROX.
AutoCAD SHX Text
1/8" WIDER DIAMETER THAN THE REBAR.
AutoCAD SHX Text
2. CLEAN OUT DUST AND FRAGMENTS; PREFERABLY
AutoCAD SHX Text
USING A JET OF WATER OR COMPRESSED AIR
AutoCAD SHX Text
AND A NYLON BRUSH. %%uDO NOT%%u USE A WIRE BRUSH.
AutoCAD SHX Text
3. INJECT APPROPRIATE EPOXY GROUT INTO
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
END OF REBAR BEING INSERTED
AutoCAD SHX Text
INTO BASE MATERIAL MUST HAVE
AutoCAD SHX Text
A 45%%D OR CHISEL POINT (90%%D)
AutoCAD SHX Text
PRE-DRILLED HOLE IN BASE MATERIAL.
AutoCAD SHX Text
4. PLACE CHISEL POINTED END OF REBAR ON TOP OF
AutoCAD SHX Text
EPOXY GROUT AND DRIVE REBAR TO BOTTOM OF HOLE.
AutoCAD SHX Text
5. CARE SHOULD BE TAKEN NOT TO DISTURB THE
AutoCAD SHX Text
INSTALLED REBAR UNTIL EPOXY GROUT HAS CURED.
AutoCAD SHX Text
EMBEDMENT DEPTH PER
AutoCAD SHX Text
EMBEDMENT DEPTH PER
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
FTG SHALL BE
AutoCAD SHX Text
FTG SHALL BE
AutoCAD SHX Text
FTG SHALL BE
AutoCAD SHX Text
FOOTING OR
AutoCAD SHX Text
BOTTOM OF WALL
AutoCAD SHX Text
TRENCH FOOTING
AutoCAD SHX Text
NO PIPE SHALL PASS THROUGH THE FOOTING PAD
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
POUR JOINT
AutoCAD SHX Text
FTG. PER
AutoCAD SHX Text
FTG. PER
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
WALL
AutoCAD SHX Text
PROVIDE MTL. SLEEVES W/ I.D. 2" GREATER THAN THE O.D. OF THE PIPE
AutoCAD SHX Text
PLACE 1,000 PSI LEAN CONCRETE FILL AROUND SLEEVES BEFORE POURING FTGS. FILL SHALL BE SAME WIDTH AS FTG AND FULL WIDTH OF PIPE TRENCH
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
EXISTING CONCRETE
AutoCAD SHX Text
DRILLED HOLE-FILL WITH EPOXY GROUT
AutoCAD SHX Text
INSTALLED ANCHOR UNTIL EPOXY GROUT HAS CURED.
AutoCAD SHX Text
5. CARE SHOULD BE TAKEN NOT TO DISTURB THE
AutoCAD SHX Text
ANCHOR TO BOTTOM OF HOLE.
AutoCAD SHX Text
4. PLACE ANCHOR ON TOP OF EPOXY GROUT AND DRIVE
AutoCAD SHX Text
PRE-DRILLED HOLE IN BASE MATERIAL.
AutoCAD SHX Text
3. INJECT APPROPRIATE EPOXY GROUT INTO
AutoCAD SHX Text
AND A NYLON BRUSH. %%uDO NOT%%u USE A WIRE BRUSH.
AutoCAD SHX Text
USING A JET OF WATER OR COMPRESSED AIR
AutoCAD SHX Text
2. CLEAN OUT DUST AND FRAGMENTS; PREFERABLY
AutoCAD SHX Text
1/8" WIDER DIAMETER THAN THAT OF ANCHOR.
AutoCAD SHX Text
1. DRILL HOLE TO THE REQUIRED DEPTH; APPROX.
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
NO PIPE SHALL PASS THROUGH THE FOOTING PAD
AutoCAD SHX Text
PROVIDE MTL. SLEEVES W/ I.D. 2" GREATER THAN THE O.D. OF THE PIPE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FTG. PER
AutoCAD SHX Text
FTG. PER
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
STANDARD DETAILS
AutoCAD SHX Text
NO SCALE
Page 3: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

TYPICAL ROOF/FLOOR NAILING PATTERN

TYPICAL BEARING WALL TOP PLATE SPLICE

TYP. WOOD STUD SHEARWALL ELEVATION U.N.O.

DETAIL 1 - TYPICAL HOLD DOWN FORSHEAR WALL BOUNDARY ELEMENT

TYPICAL LOAD BEARING STUD WALL FRAMING

DETAIL 1

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S2.2

AutoCAD SHX Text
DBL. 2x WOOD PLATES CONT.
AutoCAD SHX Text
NOTE: STAGGER TOP PLATE STAGGER TOP PLATE LAP JOINTS 4'-0" MIN. SPLICE OVER STUDS
AutoCAD SHX Text
SPLICE
AutoCAD SHX Text
SPLICE
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
10-16d EACH SIDE OF SPLICE
AutoCAD SHX Text
DIAPHRAGM BOUNDARY
AutoCAD SHX Text
USE 6d NAILS @ 4" O.C. AT PERIMETER AND ALONG SW LINES
AutoCAD SHX Text
THIS PANEL JOINT NOT CONTINUOUS
AutoCAD SHX Text
NAILING TO INTERMEDIATE MEMBERS: "FIELD" NAILING - USE 8d NAILS @ 12" O.C. MAX
AutoCAD SHX Text
4'-0"x8'-0" APA OSB/PLYWOOD PANEL, SEE GENERAL NOTES AND PLANS
AutoCAD SHX Text
CONTINUOUS PANEL JOINT
AutoCAD SHX Text
USE 8d NAILS @ 6" O.C. MAX. U.N.O. AT EDGES
AutoCAD SHX Text
FLOOR/ROOF JOISTS
AutoCAD SHX Text
BLOCKING AT PANEL BOUNDARY
AutoCAD SHX Text
7/16" APA RATED SHEATHING. SEE SCHEDULE FOR FASTENING. STAGGER HORIZONTAL JOINTS.
AutoCAD SHX Text
STUD COL. AT BOUNDARY OF SHEAR WALL
AutoCAD SHX Text
SIMPSON TITEN HD SILL ANCHOR PER SHEAR WALL SCHEDULE
AutoCAD SHX Text
PROVIDE DOUBLE STUDS AT ALL VERTICAL PANEL JOINTS. ATTACH STUDS TOGETHER WITH 16d AT 12" cc - 2 ROWS STAGGERED
AutoCAD SHX Text
SW # - SEE SCHEDULE
AutoCAD SHX Text
2x6 BLOCKING
AutoCAD SHX Text
WOOD STUDS AT 16"cc
AutoCAD SHX Text
STUD COLUMN AT BOUNDARY OF SHEAR WALL
AutoCAD SHX Text
STUD PACK SEE SCHED.
AutoCAD SHX Text
SECTION "A"
AutoCAD SHX Text
"A"
AutoCAD SHX Text
STUD COLUMN AT SHEAR WALL BOUNDARY
AutoCAD SHX Text
SHEATHING
AutoCAD SHX Text
SIMPSON TITEN HD SILL ANCHORS
AutoCAD SHX Text
HOLDOWN SEE SCHEDULE
AutoCAD SHX Text
SEE SHEAR WALL SCHEDULE FOR HOLDOWN SIZE & EMBEDMENT
AutoCAD SHX Text
HILTI HY200
AutoCAD SHX Text
9" MAX., 4 1/2" MIN.
AutoCAD SHX Text
PROVIDE DOUBLE JACK STUDS AT OPENINGS WIDER THAN 6'-0" U.N.O.
AutoCAD SHX Text
SIMPSON A35 CLIP AT EXTERIOR WALLS
AutoCAD SHX Text
2 - 16d NAILS AT EACH STUD
AutoCAD SHX Text
16d NAILS AT 16" cc STAGGERED
AutoCAD SHX Text
4 - 16d @ CORNERS AND CROSS WALL LAPS OF TOP PLATES
AutoCAD SHX Text
2x6 BLOCKING AT SHEATHING JOINTS. FOR STUDS OVER 8'-0" HIGH, PROVIDE 2x6 BLOCKING AT 1/3 POINTS w/ 2 - 10d TOENAILS OR 2 - 16d END NAILS AT BOTH ENDS OF EACH BLOCKING.
AutoCAD SHX Text
WALL AT CORNER
AutoCAD SHX Text
2x6 STUDS @ 16" cc - TYPICAL
AutoCAD SHX Text
PROVIDE DOUBLE STUDS AT EACH SIDE OF JAMBS FOR OPENINGS WIDER THAN 4'-0" U.N.O.
AutoCAD SHX Text
SEE TYP. ANCHORAGE AT BASE FOR BOLT SIZE & SPACING - SEE DETAIL 1/S2.4
AutoCAD SHX Text
HEADER SEE SCHED.
AutoCAD SHX Text
2 - 2x6 TOP PLATE
AutoCAD SHX Text
HEADER @ WINDOW SEE SCHED.
AutoCAD SHX Text
PROVIDE DOUBLE SILL PLATES AT ALL OPENINGS WIDER THAN 4'-0" U.N.O.
AutoCAD SHX Text
SEE GENERAL NOTES FOR WOOD FRAMING ON SHEET S1.1.
AutoCAD SHX Text
OPNG
AutoCAD SHX Text
PROVIDE DOUBLE KING STUDS AT OPENINGS WIDER THAN 4'-0"
AutoCAD SHX Text
2x6 TREATED SILL
AutoCAD SHX Text
TOP PLATE SPLICE DETAIL
AutoCAD SHX Text
SHEAR WALL #
AutoCAD SHX Text
SW-1
AutoCAD SHX Text
FASTENER
AutoCAD SHX Text
SHEATHING
AutoCAD SHX Text
SPACING
AutoCAD SHX Text
SILL BOLT TITEN HD
AutoCAD SHX Text
HOLDDOWN
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SHEAR WALL SCHEDULE
AutoCAD SHX Text
SW-2
AutoCAD SHX Text
SW-3
AutoCAD SHX Text
SW-4
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
#8
AutoCAD SHX Text
6
AutoCAD SHX Text
1/2" @ 24"oc
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
#8
AutoCAD SHX Text
6
AutoCAD SHX Text
#8
AutoCAD SHX Text
1/2" @ 16"oc
AutoCAD SHX Text
#8
AutoCAD SHX Text
4
AutoCAD SHX Text
SDS@24"oc
AutoCAD SHX Text
1/2" @ 24"oc
AutoCAD SHX Text
NOTES: 1. ALL BOLTS ARE ASTM F-1554, GRADE 36. ALL BOLTS ARE ASTM F-1554, GRADE 36. 2. EPOXY: SIMPSON SET-XP OR APPROVED EQUAL. EPOXY: SIMPSON SET-XP OR APPROVED EQUAL. 3. TITEN SILL BOLTS: 5/8" DIA. x 5 1/2", 1/2" DIA. x 4". TITEN SILL BOLTS: 5/8" DIA. x 5 1/2", 1/2" DIA. x 4". 4. ALL SHEATHING SHALL BE 1/2 APA RATED SHEATHING. ALL SHEATHING SHALL BE 1/2 APA RATED SHEATHING. 5. SDS 1/4 x 4.SDS 1/4 x 4.
AutoCAD SHX Text
BOUNDARY
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
SW-5
AutoCAD SHX Text
#8
AutoCAD SHX Text
4
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
6
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
1/2" @ 16"oc
AutoCAD SHX Text
2x6
AutoCAD SHX Text
ANCHOR #
AutoCAD SHX Text
ANCHOR EMBED.
AutoCAD SHX Text
SW-6
AutoCAD SHX Text
SW-7
AutoCAD SHX Text
#8
AutoCAD SHX Text
1/2" @ 16"oc
AutoCAD SHX Text
#8
AutoCAD SHX Text
4
AutoCAD SHX Text
HDU14
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
HDU14
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
SW-8
AutoCAD SHX Text
#8
AutoCAD SHX Text
4
AutoCAD SHX Text
HDU8
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
6
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
7/16 OSB
AutoCAD SHX Text
1/2" @ 16"oc
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
1/2" @ 16"oc
AutoCAD SHX Text
ANCHOR ROD SIZE
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
7/8"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1"
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
STANDARD DETAILS
AutoCAD SHX Text
NO SCALE
Page 4: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

8

S4.1

4

S4.1

4

S4.1

4

S4.1

6

S4.1

7A

S4.1

2

S4.1

1

S4.1

5

S4.1

7

S4.1

2

S4.1

2

S4.1

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S3.1

FOUNDATION AND LOWER LEVEL PLAN

AutoCAD SHX Text
UNEXCAVATED
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
SEE TYP. FOUNDATION DOWELING DETAIL ON SHEET S2.1 (TYP. NEW WALL AT EXIST.)
AutoCAD SHX Text
APPROX. LOCATION OF STEP IN FOOTING - FIELD VERIFY (TYP.)
AutoCAD SHX Text
APPROX. LOCATION OF STEP IN FOOTING - FIELD VERIFY (TYP.)
AutoCAD SHX Text
TOP OF FTG. TO MATCH EXIST. - FIELD VERIFY
AutoCAD SHX Text
TOP OF FTG. TO MATCH EXIST. - FIELD VERIFY
AutoCAD SHX Text
SEE TYP. FOUNDATION DOWELING DETAIL ON SHEET S2.1 (TYP. NEW WALL AT EXIST.)
AutoCAD SHX Text
STEP IN FTG. SEE DTL. ON S2.1 (TYP.)
AutoCAD SHX Text
EXIST. FDN. WALL - FIELD VERIFY LOCATION AND ELEVATION PRIOR TO COMMENCING CONSTR.
AutoCAD SHX Text
EXIST. FDN. WALL - FIELD VERIFY LOCATION AND ELEVATION PRIOR TO COMMENCING CONSTR.
AutoCAD SHX Text
STAIR UP SEE ARCH.
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING (TYP. AT BRG. WALL)
AutoCAD SHX Text
9' STD. BRG. WALL - SEE ARCH. DWGS.
AutoCAD SHX Text
24" W x 12" THK STRIP FOOTING
AutoCAD SHX Text
4" THICK CONCRETE SLAB OVER 10 MIL. VAPOR BARRIER AND 4" COMPACTED GRANULAR FILL. REINFORCE WITH 6x6 W2.9xW2.9 WWF TOP OF SLAB EL. 90'-4"
AutoCAD SHX Text
UNEXCAVATED
AutoCAD SHX Text
TYP. AT BRG. WALL
AutoCAD SHX Text
STEP IN FTG. SEE DTL. ON S2.1 (TYP.)
AutoCAD SHX Text
T/FTG. 88'-10"
AutoCAD SHX Text
T/FTG. 88'-10"
AutoCAD SHX Text
T/FTG. 88'-10"
AutoCAD SHX Text
T/FTG. 88'-10"
AutoCAD SHX Text
SW #5
AutoCAD SHX Text
SW #3
AutoCAD SHX Text
SW #1
AutoCAD SHX Text
SW #2
AutoCAD SHX Text
SW #4
AutoCAD SHX Text
TOP OF FTG. TO MATCH EXIST. - FIELD VERIFY
AutoCAD SHX Text
PLAN LEGEND
AutoCAD SHX Text
H2
AutoCAD SHX Text
SW-#
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DIRECTION OF SPAN
AutoCAD SHX Text
WOOD HEADER DESIGNATION SEE SCHED. ON S2.2
AutoCAD SHX Text
SHEAR WALL DESIGNATION
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
FDN./LOWER LEVEL PLAN
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
PLAN NOTES: : 1. TOP OF BUILDING ADDITION SLAB TO MATCH EXISTING TOP OF SLAB ELEVATION. FIELD VERIFY ALL TOP OF BUILDING ADDITION SLAB TO MATCH EXISTING TOP OF SLAB ELEVATION. FIELD VERIFY ALL ELEVATIONS PRIOR TO COMMENCING CONSTRUCTION. 2. CONTRACTOR TO FIELD VERIFY ALL EXISTING FOUNDATION CONDITIONS PRIOR TO START OF CONTRACTOR TO FIELD VERIFY ALL EXISTING FOUNDATION CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCIES WITH THE DRAWINGS. 3. FLOOR CONSTRUCTION TO BE 4" CONCRETE SLAB ON GRADE OVER 10 MIL. POLY VAPOR BARRIER OVER FLOOR CONSTRUCTION TO BE 4" CONCRETE SLAB ON GRADE OVER 10 MIL. POLY VAPOR BARRIER OVER 4" GRANULAR FILL. REINFORCE SLAB WITH 6x6-W2.9xW2.9 W.W.F. 4. COLUMN FOOTINGS ARE CENTERED EACH WAY ON COLUMN CENTERS UNLESS NOTED OTHERWISE. COLUMN FOOTINGS ARE CENTERED EACH WAY ON COLUMN CENTERS UNLESS NOTED OTHERWISE. 5. SEE PLAN FOR TOP OF ALL FOOTING ELEVATIONS. SEE PLAN FOR TOP OF ALL FOOTING ELEVATIONS. 6. BOTTOM OF NEW FOUNDATION WALL STRIP FOOTINGS TO BE A MINIMUM OF 30" BELOW FINISH GRADE BOTTOM OF NEW FOUNDATION WALL STRIP FOOTINGS TO BE A MINIMUM OF 30" BELOW FINISH GRADE AT THE BUILDING - AND/OR - MATCH THE BOTTOM OF THE EXISTING ADJACENT FOOTING IF EXISTING FOUNDATION IS IN CLOSE PROXIMITY TO THE NEW WORK. 7. SEE SHEET S2.1 AND S2.2 FOR STANDARD DETAILS. SEE SHEET S2.1 AND S2.2 FOR STANDARD DETAILS. 8. SEE SHEET S5.0 FOR SHEAR WALL ELEVATIONS (SW-#). SEE SHEET S5.0 FOR SHEAR WALL ELEVATIONS (SW-#). 9. SEE ARCH. DWGS. FOR SLOPED AND/OR DEPRESSED SLABS, CONCRETE FINISHES AND TREATMENTS. SEE ARCH. DWGS. FOR SLOPED AND/OR DEPRESSED SLABS, CONCRETE FINISHES AND TREATMENTS. 7. SEE ARCHITECT'S DRAWINGS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION. SEE ARCHITECT'S DRAWINGS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION. 8. SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING INFORMATION.SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING INFORMATION.
Page 5: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

4

S4.1

4

S4.1

4

S4.1

7

S4.1

6

S4.1

7A

S4.1

8

S4.1

3

S4.1

3

S4.1

2

S4.1

1

S4.1

2

S4.1

9

S4.1

9

S4.1

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S3.2

FIRST FLOOR PLAN

AutoCAD SHX Text
FLOOR CONSTRUCTION: 3/4" PLYWOOD SHEATHING OVER WOOD TRUSSES
AutoCAD SHX Text
4" THICK CONCRETE SLAB OVER 10 MIL. VAPOR BARRIER AND 4" COMPACTED GRANULAR FILL. REINFORCE WITH 6x6 W2.9xW2.9 WWF TOP OF SLAB EL. 100'-0"
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
FACE OF FDN. WALL
AutoCAD SHX Text
SEE TYP. FOUNDATION DOWELING DETAIL ON SHEET S2.1 (TYP. NEW WALL AT EXIST.)
AutoCAD SHX Text
SEE TYP. FOUNDATION DOWELING DETAIL ON SHEET S2.1 (TYP. NEW WALL AT EXIST.)
AutoCAD SHX Text
T/WALL 99'-4" (TYP. AT DOORS)
AutoCAD SHX Text
EXIST. FDN. WALL - FIELD VERIFY LOCATION AND ELEVATION PRIOR TO COMMENCING CONSTR.
AutoCAD SHX Text
EXIST. FDN. WALL - FIELD VERIFY LOCATION AND ELEVATION PRIOR TO COMMENCING CONSTR.
AutoCAD SHX Text
STAIR DOWN SEE ARCH.
AutoCAD SHX Text
EXIST. 6" CONC. SLAB ON GRADE
AutoCAD SHX Text
EXIST. 4" CONC. SLAB ON GRADE
AutoCAD SHX Text
EXIST. 4" CONC. SLAB ON GRADE F.F. 100'-0"
AutoCAD SHX Text
EXIST. CONC. SLAB ON GRADE SLAB SLOPES TO DRAIN
AutoCAD SHX Text
EXIST. CONC. SLAB ON GRADE F.F. 100'-0"
AutoCAD SHX Text
EXIST. CONC. SLAB ON GRADE
AutoCAD SHX Text
4" THICK CONCRETE SLAB OVER 10 MIL. VAPOR BARRIER AND 4" COMPACTED GRANULAR FILL. REINFORCE WITH 6x6 W2.9xW2.9 WWF TOP OF SLAB EL. TO MATCH EXIST. BLDG. SLAB
AutoCAD SHX Text
2x6 STUD WALL @ 16" O.C.
AutoCAD SHX Text
2x6 STUD WALL @ 16" O.C.
AutoCAD SHX Text
NOTE: BRACE TRUSSES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS
AutoCAD SHX Text
PATIO SLAB
AutoCAD SHX Text
SW #5
AutoCAD SHX Text
SW #3
AutoCAD SHX Text
SW #1
AutoCAD SHX Text
SW #2
AutoCAD SHX Text
SW #4
AutoCAD SHX Text
SPAN
AutoCAD SHX Text
EXIST. TRENCH DRAIN
AutoCAD SHX Text
OPENING BELOW w/CONC. BEAM HEADER - EXTEND BEAM 8" PAST OPNG. EA. SIDE (TYP. 2 PLACES)
AutoCAD SHX Text
PLAN LEGEND
AutoCAD SHX Text
H2
AutoCAD SHX Text
SW-#
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DIRECTION OF SPAN
AutoCAD SHX Text
WOOD HEADER DESIGNATION SEE SCHED. ON S2.2
AutoCAD SHX Text
SHEAR WALL DESIGNATION
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
FIRST FLOOR PLAN
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
PLAN NOTES: : 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING FOUNDATION CONDITIONS PRIOR TO START CONTRACTOR TO FIELD VERIFY ALL EXISTING FOUNDATION CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCIES WITH THE DRAWINGS. 2. FLOOR CONSTRUCTION TO BE 4" CONCRETE SLAB ON GRADE OVER 10 MIL. POLY VAPOR FLOOR CONSTRUCTION TO BE 4" CONCRETE SLAB ON GRADE OVER 10 MIL. POLY VAPOR BARRIER OVER 4" GRANULAR FILL. REINFORCE SLAB WITH 6x6-W2.9xW2.9 W.W.F. 3. COLUMN FOOTINGS ARE CENTERED EACH WAY ON COLUMN CENTERS UNLESS NOTED COLUMN FOOTINGS ARE CENTERED EACH WAY ON COLUMN CENTERS UNLESS NOTED OTHERWISE. 4. SEE SHEET S1.1, S2.1 AND S2.2 FOR GENERAL NOTES AND STANDARD DETAILS. SEE SHEET S1.1, S2.1 AND S2.2 FOR GENERAL NOTES AND STANDARD DETAILS. 5. SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING AND DEMOLITION INFORMATION.SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING AND DEMOLITION INFORMATION.
Page 6: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

7

S4.1

7

S4.1

7

S4.17A

S4.1

6

S4.1

6

S4.1

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S3.3

ROOF FRAMING PLAN

AutoCAD SHX Text
EXIST. ROOF
AutoCAD SHX Text
SLOPE 4:12
AutoCAD SHX Text
SLOPE 4:12
AutoCAD SHX Text
SLOPE 4:12
AutoCAD SHX Text
SLOPE 4:12
AutoCAD SHX Text
CRICKET
AutoCAD SHX Text
2x8 LEDGER BOARD
AutoCAD SHX Text
2x8 LEDGER BOARD
AutoCAD SHX Text
2x10 RAFTERS @ 16" O.C.
AutoCAD SHX Text
DBL. 2x12 RIDGE BEAM
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H2
AutoCAD SHX Text
H3
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
1.9E-2600F 2-1.75x11.875" LVL
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
H1
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SIM
AutoCAD SHX Text
1.9E-2600F 3.5"x14" LVL
AutoCAD SHX Text
1.9E-2600F 3.5"x16" LVL
AutoCAD SHX Text
1.9E-2600F 3.5"x16" LVL
AutoCAD SHX Text
3 JACK / 2 KING
AutoCAD SHX Text
3 JACK & 2 KING STUDS EACH END
AutoCAD SHX Text
3 JACK & 2 KING STUDS EACH END
AutoCAD SHX Text
3 JACK & 2 KING STUDS EACH END
AutoCAD SHX Text
H1
AutoCAD SHX Text
SEE NOTE ON SHT. S5.1
AutoCAD SHX Text
3 - 16d NAILS THRU JAMB STUDS INTO EACH END OF EACH VERTICAL
AutoCAD SHX Text
SEE SCHEDULE FOR MEMBER SIZE
AutoCAD SHX Text
WOOD HEADER SCHEDULE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
HEADER
AutoCAD SHX Text
H1
AutoCAD SHX Text
H2
AutoCAD SHX Text
H3
AutoCAD SHX Text
2x6 TOP PLATE
AutoCAD SHX Text
2x6 BOTTOM PLATE
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
KING STUDS
AutoCAD SHX Text
JACK STUDS
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SUPPORT FRAMING
AutoCAD SHX Text
1-2x6
AutoCAD SHX Text
1-2x6
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
2-2x6
AutoCAD SHX Text
2x8
AutoCAD SHX Text
2-2x10
AutoCAD SHX Text
3-1 3/4x14
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
PLAN NOTES: : 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCIES WITH THE DRAWINGS. 2. SEE SHEET S1.0 FOR STRUCTURAL GENERAL NOTES. SEE SHEET S1.0 FOR STRUCTURAL GENERAL NOTES. 3. SEE SHEET S2.1 AND S2.2 FOR STRUCTURAL STANDARD DETAILS. SEE SHEET S2.1 AND S2.2 FOR STRUCTURAL STANDARD DETAILS. 4. SEE SHEET S5.1 FOR SHEAR WALL ELEVATIONS. SEE SHEET S5.1 FOR SHEAR WALL ELEVATIONS. 5. SEE ARCHITECT'S DRAWINGS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION. SEE ARCHITECT'S DRAWINGS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION. 6. SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING INFORMATION.SEE ARCHITECT'S DRAWINGS FOR EXISTING BUILDING INFORMATION.
Page 7: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S4.1

AutoCAD SHX Text
FLOOR SLAB - SEE PLAN MATCH EXIST. T/SLAB EL.
AutoCAD SHX Text
EXIST. FDN. WALL AND FOOTING
AutoCAD SHX Text
EXIST. CONC. FLOOR SLAB
AutoCAD SHX Text
EXIST. FF EL 100'-0" (0'-0" ARCH.)
AutoCAD SHX Text
BOND BREAKER
AutoCAD SHX Text
EXIST. WALL CONSTRUCTION U.I.P. OR REMOVE - SEE ARCH DWGS.
AutoCAD SHX Text
SECTION 1
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1
AutoCAD SHX Text
#5 x 12" LG. DOWELS @ 12" O.C. DRILL AND EPOXY INTO EXIST. CONC. STEM WALL.
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
FIELD VERIFY BOT/EX. FTG. EL.
AutoCAD SHX Text
CONC. SLAB SEE PLAN
AutoCAD SHX Text
3-#4 CONT.
AutoCAD SHX Text
SECTION 5
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
GRANULAR BACKFILL
AutoCAD SHX Text
SECTION 2
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1
AutoCAD SHX Text
FIN. GRADE
AutoCAD SHX Text
DOOR BEYOND
AutoCAD SHX Text
PATIO SLAB SEE PLAN
AutoCAD SHX Text
FIN. GRADE
AutoCAD SHX Text
WWF
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
1/2" E.J. FILLER
AutoCAD SHX Text
SEE ARCH DWGS. FOR WALL CONSTRUCTION
AutoCAD SHX Text
GRANULAR BACKFILL
AutoCAD SHX Text
SECTION 4
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
SECTION 3
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1
AutoCAD SHX Text
S3.2
AutoCAD SHX Text
ANCHOR BOLTS - SEE TYP. WALL DETAIL ON SHEET S2.1
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
TREATED 2x SILL PLATE
AutoCAD SHX Text
#4@12" O.C. VERT. CTR. IN WALL. ALT. HOOKS
AutoCAD SHX Text
2-#4 CONT., T&B
AutoCAD SHX Text
#4 DOWELS TO MATCH WALL VERTS.
AutoCAD SHX Text
2-#4 CONT.
AutoCAD SHX Text
SEE SECT. 2/S4.1 FOR WALL REINFORCING
AutoCAD SHX Text
2x6 @ 16" O.C. BEARING WALL
AutoCAD SHX Text
ANCHOR BOLTS - SEE TYP. WALL DETAIL ON SHEET S2.1
AutoCAD SHX Text
TREATED 2x6 SILL PLATE
AutoCAD SHX Text
#4@12"O.C.
AutoCAD SHX Text
POUR INTEGRAL WITH SLAB
AutoCAD SHX Text
SHEATING PER PLAN
AutoCAD SHX Text
SEE SECT. 7/S4.1 FOR WALL REINFORCING AND BALANCE OF INFO.
AutoCAD SHX Text
SECTION 6
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1 S3.2 S3.3
AutoCAD SHX Text
FIN. GRADE
AutoCAD SHX Text
SECTION 7
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1 S3.2 S3.3
AutoCAD SHX Text
ANCHOR BOLTS - SEE TYP. WALL DETAIL ON SHEET S2.1
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
FLOOR JOISTS PER PLAN
AutoCAD SHX Text
EXTEND SLAB TO O.F. OF WALL AND TURN DOWN AT DOOR OPENINGS
AutoCAD SHX Text
SHEATING PER PLAN
AutoCAD SHX Text
SEE SECT. 7/S4.1 FOR FDN. WALL REINFORCING
AutoCAD SHX Text
SECTION 8
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1 S3.2
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
EXIST. WALL
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
FLOOR JOISTS PER PLAN
AutoCAD SHX Text
FIN. FLR. 100'-0"
AutoCAD SHX Text
EXIST. FDN. WALL
AutoCAD SHX Text
FIN. FLR. 90'-4"
AutoCAD SHX Text
EXIST. GRADE
AutoCAD SHX Text
EXIST. CONC. SLAB
AutoCAD SHX Text
COMPACTED CLEAN ROCK BACKFILL
AutoCAD SHX Text
EXIST. FOOTING FIELD VERIFY FTG. ELEVATION
AutoCAD SHX Text
PROPOSED ADDITION
AutoCAD SHX Text
CONC. SLAB PER PLAN
AutoCAD SHX Text
STEP FTG. AT WALL BEYOND
AutoCAD SHX Text
JOIST HANGER
AutoCAD SHX Text
SECTION 7A
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
S3.1 S3.2 S3.3
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
FLOOR JOISTS PER PLAN
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
FIN. FLR. 90'-4"
AutoCAD SHX Text
2-#4 CONT.
AutoCAD SHX Text
SHEATING PER PLAN
AutoCAD SHX Text
TREATED 2x BOT. PLATE
AutoCAD SHX Text
2x6 STUDS @ 16" O.C.
AutoCAD SHX Text
FIN. FLR. 100'-0"
AutoCAD SHX Text
JOIST HANGER
AutoCAD SHX Text
SIDEWALK SEE CIVIL
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
FLOOR JOISTS PER PLAN
AutoCAD SHX Text
SLAB - SEE PLAN
AutoCAD SHX Text
FIN. FLR. 90'-4"
AutoCAD SHX Text
2-#4 CONT., T&B
AutoCAD SHX Text
#4@12" O.C. VERT. CTR. IN WALL. ALT. HOOKS
AutoCAD SHX Text
2-#4 CONT.
AutoCAD SHX Text
#4@18" O.C. CONT.
AutoCAD SHX Text
SHEATING PER PLAN
AutoCAD SHX Text
SEE ARCH DWGS. FOR WALL CONSTRUCTION
AutoCAD SHX Text
TREATED 2x BOT. PLATE
AutoCAD SHX Text
2x6 STUDS @ 16" O.C.
AutoCAD SHX Text
FIN. FLR. 100'-0"
AutoCAD SHX Text
SEE SECT. 7/S4.1 FOR WALL REINFORCING AND BALANCE OF INFO.
AutoCAD SHX Text
TREATED 2x LEDGER BD. w/ 2-1/2" DIA. EXP. BOLTS w/4" EMBED. MIN. @ 12" O.C. T&B
AutoCAD SHX Text
SEE ARCH DWGS. FOR WALL CONSTRUCTION
AutoCAD SHX Text
2x6 STUDS @ 16" O.C.
AutoCAD SHX Text
T/FTG. PER PLAN
AutoCAD SHX Text
FIN. FLR. 100'-0"
AutoCAD SHX Text
FIN. FLR. 90'-4"
AutoCAD SHX Text
TURN DN. SLAB TO T/FTG.
AutoCAD SHX Text
#5 x 12" LG. DOWELS @ 12" O.C. DRILL AND EPOXY INTO EXIST. CONC FDN. WALL.
AutoCAD SHX Text
#5 DOWELS @ 12" O.C.
AutoCAD SHX Text
MATCH EXIST. ROOF SLOPE
AutoCAD SHX Text
PRE-ENGINEERED GABLE ROOF TRUSS - SEE ROOF PLAN
AutoCAD SHX Text
T/PLATE - MATCH EXIST.
AutoCAD SHX Text
SEE ARCH DWGS. FOR WALL CONSTRUCTION
AutoCAD SHX Text
2x TOP PLATE
AutoCAD SHX Text
SIMPSON H1 HURRICANE TIE AT EACH TRUSS. INSTALL WITH 0.131 x 1 1/2" NAILS
AutoCAD SHX Text
MATCH EXIST. ROOF SLOPE
AutoCAD SHX Text
PRE-ENGINEERED GABLE ROOF TRUSS - SEE ROOF PLAN
AutoCAD SHX Text
T/PLATE - MATCH EXIST.
AutoCAD SHX Text
T/PLATE - MATCH EXIST.
AutoCAD SHX Text
PRE-ENGINEERED GABLE ROOF TRUSS (TYP.)
AutoCAD SHX Text
FASCIA BD. PER ARCH.
AutoCAD SHX Text
FASCIA BD. PER ARCH.
AutoCAD SHX Text
2x TOP PLATE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
2x TOP PLATE
AutoCAD SHX Text
SIMPSON H1 HURRICANE TIE AT EACH TRUSS. INSTALL WITH 0.131 x 1 1/2" NAILS
AutoCAD SHX Text
OPENING
AutoCAD SHX Text
STEEL PL. 1/2"x8" WITH 1/2" DIA. x 4" LG. HEADED STUDS WELDED TO PLATE AT 12" O.C.
AutoCAD SHX Text
CONC. BEAM 8"x18" WITH 2-#5 CONT. T&B AND #3 TIES @ 12" O.C.
AutoCAD SHX Text
8" CONC. FOUNDATION WALL - SEE PLAN
AutoCAD SHX Text
NOTE: EXTEND CONC. EXTEND CONC. BEAM AND STEEL PLATE 8" BEYOND OPENING EACH SIDE.
AutoCAD SHX Text
SECTION 9
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
S3.2
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
AS NOTED
Page 8: TYPICAL SECTION AT DOOR TYPICAL INTERIOR COLUMN DETAILS · given to avoid conflicts with existing rebar. holes shall be drilled and cleaned per manufacturer’s instructions. do not

Dat

eR

evis

ions

OW

NE

R:

SE

AL:

CIV

IL E

NG

INE

ER

OF

FIC

E: (6

36

) 7

97

-8

42

5

CE

LL

: (3

14

) 9

52

-5

03

8

10

78

5 B

US

IN

ES

S 2

1, S

UIT

E A

HIL

LS

BO

RO

, M

IS

SO

UR

I 6

30

50

dvo

na

rx@

vo

na

rxe

ng

in

ee

rin

g.co

m

CE

RT

IF

IC

AT

E O

F A

UT

HO

RIT

Y 0

97

5

BAC

ON

CO

MM

ERC

IAL

DES

IGN

STEV

EN J

. BAC

ON

100

BAIL

EY R

OAD

#A

CRY

STAL

CIT

Y, M

O 6

3019

(636

) 933

-000

7

05/0

7/19

ISS

UE

FO

R B

ID

S5.1

FRONT ELEVATION

REAR SHEAR WALL ELEVATION

LEFT SIDE SHEAR WALL ELEVATION

RIGHT SIDE SHEAR WALL ELEVATION

AutoCAD SHX Text
SW #7
AutoCAD SHX Text
HDU14 (TYP.)
AutoCAD SHX Text
FILL SPACE WITH 2x6 KING STUDS. LEAVE ROOM FOR HOLD DOWNS. PROVIDE SHOP DRAWING SUBMITTAL PRIOR TO ROUGH FRAMING
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
HDU8 (TYP.)
AutoCAD SHX Text
A
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
A
AutoCAD SHX Text
SW #8
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
HDU8 (TYP.)
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
HDU8 (TYP.)
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
SW #3
AutoCAD SHX Text
SW #1
AutoCAD SHX Text
B
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
8"x18" CONC. BEAM
AutoCAD SHX Text
B
AutoCAD SHX Text
HDU8 (TYP.)
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
HDU8 (TYP.)
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
SW #4
AutoCAD SHX Text
SW #2
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
CONC. FOUNDATION WALL
AutoCAD SHX Text
8"x18" CONC. BEAM
AutoCAD SHX Text
5/8"Ø @ 16"o.c.
AutoCAD SHX Text
S/HD8 (TYP.)
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
10d @ 4"o.c.
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
2 - 2x6
AutoCAD SHX Text
SW #5
AutoCAD SHX Text
HDU14 (TYP.)
AutoCAD SHX Text
SW #6
AutoCAD SHX Text
FILL SPACE WITH 2x6 KING STUDS. LEAVE ROOM FOR HOLD DOWNS. PROVIDE SHOP DRAWING SUBMITTAL PRIOR TO ROUGH FRAMING
AutoCAD SHX Text
PLAN LEGEND
AutoCAD SHX Text
H2
AutoCAD SHX Text
SW-#
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DIRECTION OF SPAN
AutoCAD SHX Text
WOOD HEADER DESIGNATION SEE SCHED. ON S2.2
AutoCAD SHX Text
SHEAR WALL DESIGNATION
AutoCAD SHX Text
Sheet Number
AutoCAD SHX Text
Job Number
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
04/11/2019
AutoCAD SHX Text
15046-1
AutoCAD SHX Text
DAVID L. VONARX E-26647
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SALINE VALLEY FPD HOUSE #2 FENTON, MISSOURI JEFFERSON COUNTY
AutoCAD SHX Text
SHEAR WALL ELEVATIONS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
3/16"=1'-0"